Genomics and proteomics search results

POROS® CaptureSelect® LC Lambda Affinity Column, 10 x 100 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
10 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Volume (Metric)
7.9 ml column volume
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
15.8 ml
Elution Volume - min
7.9 ml
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469173
92e908c80626139b872f1ef23777299a_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 2.1 x 30 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
2.1 mm (diameter) x 30 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Volume (Metric)
100 µl column volume
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
200 µl
Elution Volume - min
100 µl
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469150
cb897ebccbdfbf1da4293133d700f94c_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 4.6 x 50 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 50 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Volume (Metric)
800 µl column volume
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
1.6 ml
Elution Volume - min
800 µl
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469163
48a9f4d544b8ea44c64055e29e81285d_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 4.6 x 100 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Volume (Metric)
1.7 ml column volume
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
3.4 ml
Elution Volume - min
1.7 ml
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
80 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469168
90197bc8f38e59383d79d1498757e57f_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 4.6 x 100 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Volume (Metric)
1.7 ml column volume
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
3.4 ml
Elution Volume - min
1.7 ml
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469167
469611ebdf3f038c8a93112f6c3eb0ec_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 10 x 100 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
10 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Volume (Metric)
7.9 ml column volume
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
15.8 ml
Elution Volume - min
7.9 ml
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469172
48154e219be9b4b7a68a7e0e0216b31c_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 4.6 x 50 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 50 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Volume (Metric)
800 µl column volume
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
1.6 ml
Elution Volume - min
800 µl
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469162
10f32bd07fbddae2559736d8c1c9571f_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 2.1 x 30 mm (Applied Biosystems™)

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
2.1 mm (diameter) x 30 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Volume (Metric)
100 µl column volume
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
Affinity Column
PrePacked Column
Elution Volume - max
200 µl
Elution Volume - min
100 µl
Sample Type (Specific)
Cell Culture Supernatants
For use with (Equipment)
HPLC
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469149
3f383a2a95a23943bce2e0b90c3d38bf_CmgtBuyProduct

CaptureSelect™ LC-lambda (rat) Affinity Matrix

The CaptureSelect™ LC-lambda (rat) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of Ig's from rat and guinea pig. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, whic ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194324010
749b78581757e892bebbeeae69edea36_CmgtBuyProduct

CaptureSelect™ LC-lambda (mouse) Affinity Matrix

The CaptureSelect™ LC-lambda (mouse) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of mouse Ig’s. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, which enables purific ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194323050
d4a8b6002b52b32acfe67278ebbdec7f_CmgtBuyProduct

CaptureSelect™ LC-lambda (ung) Affinity Matrix

The CaptureSelect™ LC-lambda (ung) Affinity Matrix enables depletion/purification of ungulate Ig’s, Fab fragments, and free light chains without cross reactivity to human and mouse immunoglobulins. The ligand binds to the constant part of the lambda light chain of hoofed animals ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191314005
9588bcc1f83e72b455e54297320786ab_CmgtBuyProduct

CaptureSelect™ Biotin Anti-LC-lambda (Human) Conjugate

CaptureSelect™ Biotin Anti-LC-lambda (Hu) Conjugate consists of a 13 kDa llama antibody fragment (affinity ligand) that specifically binds to the constant domain of human lambda light chains. The affinity ligand is chemically conjugated to biotin via an appropriate spacer that re ...

Specifications

Ligand Type
Antibody
Target Isotype
Lambda Light Chain
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

7103082100
e6df4ac440338bcdbcacec613659b42d_CmgtBuyProduct

CaptureSelect™ LC-lambda (Hu) Affinity Matrix

This is one of a group of CaptureSelect™ Antibody Toolbox® affinity resins designed for the simple, single-step purification of all antibody subtypes and fragments. Unlike the common bacterial coat protein matrices (e.g., Protein A, G, and L), the Antibody Toolbox resins were spe ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

084950
87073d9482c1e8c368f6b4658ee90491_CmgtBuyProduct

CaptureSelect™ LC-lambda (ung) Affinity Matrix

This is one of a group of CaptureSelect™ Antibody Toolbox® affinity resins designed for the simple, single-step purification of all antibody subtypes and fragments. Unlike the common bacterial coat protein matrices (e.g., Protein A, G, and L), the Antibody Toolbox resins were spe ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191314050
aa4fca6013d807a6766008344e1ce587_CmgtBuyProduct

POROS® GoPure™ XS Pre-packed Column, 0.5 x 5 cm, 1 mL (Applied Biosystems™)

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Particle Size
50 micron
Immobilized Phase
Sulphopropyl
Column or Resin Type
Cation Exchange Column
Sample Type (Specific)
Cell Culture Supernatants
Serum
Biopharmaceutical Purification Sample
For use with (Equipment)
FPLC
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481317
7f4a444aa8ec0ace5c632fb99220bc98_CmgtBuyProduct