{"id":1037,"date":"2026-03-18T08:37:58","date_gmt":"2026-03-18T08:37:58","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1037"},"modified":"2026-04-22T21:59:30","modified_gmt":"2026-04-22T21:59:30","slug":"fc-receptor-blocking-in-flow-cytometry","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/","title":{"rendered":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae"},"content":{"rendered":"<style>.wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79, .wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79[data-kb-block=\"kb-adv-heading1037_9cfea3-79\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79[data-kb-block=\"kb-adv-heading1037_9cfea3-79\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading1037_9cfea3-79[data-kb-block=\"kb-adv-heading1037_9cfea3-79\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading1037_9cfea3-79 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading1037_9cfea3-79\"><strong>\u4ec0\u4e48\u662fFc\u53d7\u4f53\u5c01\u95ed\uff1f<\/strong><\/h2>\n\n\n\n<p>\u63d0\u5230Fc\u53d7\u4f53\u5c01\u95ed\uff0c\u9996\u5148\u8981\u5f04\u6e05\u695a\u4ec0\u4e48\u662fFc\u53d7\u4f53\u3002Fc\u53d7\u4f53\u662f\u4e00\u7c7b\u8868\u8fbe\u5728\u67d0\u4e9b\u7ec6\u80de\u6bd4\u5982\u7c92\u7ec6\u80de\u3001B\u6dcb\u5df4\u7ec6\u80de\u3001\u6811\u7a81\u7ec6\u80de\u3001\u5de8\u566c\u7ec6\u80de\u53ca\u81ea\u7136\u6740\u4f24\u7ec6\u80de\u7b49\u7ec6\u80de\u8868\u9762\u7684\u53d7\u4f53\u86cb\u767d \uff08\u56fe1\uff09\u3002Fc\u53d7\u4f53\u80fd\u591f\u8ddf\u6297\u4f53\u7684Fc\u6bb5\u7ed3\u5408\uff08\u56fe2\uff09\uff0c\u901a\u8fc7\u8ddf\u6297\u4f53\u7684\u7ed3\u5408\uff0cFc\u53d7\u4f53\u80fd\u591f\u4fc3\u8fdb\u75c5\u539f\u4f53\u3001\u80bf\u7624\u7ec6\u80de\u6216\u8005\u88ab\u611f\u67d3\u7ec6\u80de\u7684\u6e05\u9664\uff08\u56fe3\uff09\u3002\u901a\u8fc7\u67d0\u79cd\u65b9\u5f0f\u963b\u65adFc\u53d7\u4f53\u548c\u6297\u4f53\u7ed3\u5408\u5c31\u53eb\u505a<strong>Fc\u53d7\u4f53\u5c01\u95ed<\/strong>\u3002<\/p>\n\n\n\n<p>IgG\u662f\u6700\u5e38\u89c1\u7684\u6297\u4f53\u7c7b\u578b\uff0c\u800c\u80fd\u591f\u8ddfIgG\u7ed3\u5408\u7684Fc\u53d7\u4f53\u79f0\u4e3aFc\u03b3\u53d7\u4f53\uff0c\u4e3b\u8981\u5206\u4e3aFc\u03b3RI (CD64)\u3001Fc\u03b3RIIa (CD32a)\u3001Fc\u03b3RIIb (CD32b)\u3001Fc\u03b3RIIc (CD32c)\u3001Fc\u03b3RIIIa (CD16a) \u548cFc\u03b3RIIIb (CD16b)\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"813\" height=\"587\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg\" alt=\"Fc\u03b3\u53d7\u4f53\u7684\u4e3b\u8981\u7c7b\u578b\u53ca\u5176\u5206\u5e03\u7684\u7ec6\u80de\u7c7b\u578b\" class=\"wp-image-1039\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg 813w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-300x217.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-768x555.jpg 768w\" sizes=\"auto, (max-width: 813px) 100vw, 813px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe1. Fc\u03b3\u53d7\u4f53\u7684\u4e3b\u8981\u7c7b\u578b\u53ca\u5176\u5206\u5e03\u7684\u7ec6\u80de\u7c7b\u578b\u3002+, \u7ec4\u6210\u6027\u8868\u8fbe; \u2013, \u4e0d\u8868\u8fbe; #, \u8bf1\u5bfc\u6027\u8868\u8fbe; *, \u8868\u8fbe\u4f9d\u8d56\u4e8eFCGR2C\u7b49\u4f4d\u57fa\u56e0\u72b6\u6001\u3002<\/strong>\u56fe\u7247\u51fa\u5904\uff1aBournazos, S., Gupta, A. &amp; Ravetch, J.V. The role of IgG Fc receptors in antibody-dependent enhancement. Nat Rev Immunol 20, 633\u2013643 (2020). https:\/\/doi.org\/10.1038\/s41577-020-00410-0.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"494\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-1-1024x494.jpg\" alt=\"\" class=\"wp-image-1040\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-1-1024x494.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-1-300x145.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-1-768x370.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1-1.jpg 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe2. IgG\u6297\u4f53\u7ed3\u6784\u53ca\u5176\u4e0eFc\u53d7\u4f53\u7ed3\u5408\u7684\u793a\u610f\u56fe\u3002<\/strong>\u56fe\u7247\u51fa\u5904\uff1aBarb AW. Fc \u03b3 receptor compositional heterogeneity: Considerations for immunotherapy development. J Biol Chem. 2021 Jan-Jun;296:100057. doi: 10.1074\/jbc.REV120.013168.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"631\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-2-1024x631.jpg\" alt=\"\" class=\"wp-image-1041\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-2-1024x631.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-2-300x185.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-2-768x473.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-2.jpg 1028w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe3. Fc\u53d7\u4f53\u901a\u8fc7\u4e0e\u6297\u4f53\u7ed3\u5408\u4fc3\u8fdb\u75c5\u539f\u4f53\uff0c\u80bf\u7624\u7ec6\u80de\u6216\u8005\u88ab\u611f\u67d3\u7ec6\u80de\u7684\u6e05\u9664\u3002<\/strong>\u56fe\u7247\u51fa\u5904\uff1aKang TH, Jung ST. Boosting therapeutic potency of antibodies by taming Fc domain functions. Exp Mol Med. 2019 Nov 18;51(11):1-9. doi: 10.1038\/s12276-019-0345-9.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f, .wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f[data-kb-block=\"kb-adv-heading1037_c047db-6f\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f[data-kb-block=\"kb-adv-heading1037_c047db-6f\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading1037_c047db-6f[data-kb-block=\"kb-adv-heading1037_c047db-6f\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading1037_c047db-6f wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading1037_c047db-6f\"><strong>\u4e3a\u4ec0\u4e48\u8981\u505aFc\u53d7\u4f53\u5c01\u95ed\uff1f<\/strong><\/h2>\n\n\n\n<p>\u5bf9\u4e8e\u8fd9\u4e2a\u95ee\u9898\uff0c\u76f8\u4fe1\u540c\u5b66\u4eec\u5728\u4e86\u89e3\u4e86\u4ec0\u4e48\u662fFc\u53d7\u4f53\u53ca\u5176\u7279\u6027\u4e4b\u540e\u4e5f\u80fd\u731c\u51fa\u5927\u6982\u3002\u6ca1\u9519\uff0c\u6211\u4eec\u4f7f\u7528\u7684\u6d41\u5f0f\u6297\u4f53\u80fd\u591f\u901a\u8fc7Fc\u6bb5\u4e0e\u7ec6\u80de\u4e0a\u7684Fc\u53d7\u4f53\u7ed3\u5408\uff0c\u8fd9\u79cd\u7ed3\u5408\u5bf9\u4e8e\u6211\u4eec\u7684\u6d41\u5f0f\u5b9e\u9a8c\u6765\u8bf4\u5c31\u662f\u4e00\u79cd\u201c\u975e\u7279\u5f02\u6027\u201d\u7684\u7ed3\u5408\uff0c\u4f1a\u9020\u6210\u9ad8\u80cc\u666f\u548c\u5047\u9633\u6027\u7b49\u95ee\u9898\u3002<\/p>\n\n\n\n<p>\u5728\u56fe4\u4e2d\uff0c\u6211\u4eec\u5c06\u672a\u7ecfFc\u53d7\u4f53\u5c01\u95ed\u548c\u7ecf\u8fc7Fc\u53d7\u4f53\u5c01\u95ed\u7684THP-1\u7ec6\u80de\uff08\u4eba\u6e90\u5355\u6838\u7ec6\u80de\u7cfb\uff09\u8fdb\u884cAnti-mouse IgG2a\u03ba Isotype Control (APC)\u67d3\u8272\uff0c\u53d1\u73b0\u672a\u7ecfFc\u53d7\u4f53\u5c01\u95ed\u7684\u7ec6\u80de\u6709\u660e\u663e\u7684\u5047\u9633\u6027\u4fe1\u53f7\uff08\u7d2b\u7ebf\uff09\uff0c\u800cFc\u53d7\u4f53\u5c01\u95ed\u80fd\u591f\u6709\u6548\u7684\u6d88\u9664\u8fd9\u90e8\u5206\u4fe1\u53f7\uff08\u84dd\u7ebf\uff09\u3002\u7070\u7ebf\u4ee3\u8868\u672a\u5c01\u95ed\u4e5f\u672a\u67d3\u8272\u7ec6\u80de\u7684\u81ea\u53d1\u8367\u5149\u4fe1\u53f7\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"407\" height=\"397\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/5570e6568fe5a73e074bd4fcfeed030b-1.png\" alt=\"\" class=\"wp-image-1043\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/5570e6568fe5a73e074bd4fcfeed030b-1.png 407w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/5570e6568fe5a73e074bd4fcfeed030b-1-300x293.png 300w\" sizes=\"auto, (max-width: 407px) 100vw, 407px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe4. Fc Receptor Binding Inhibitor Antibody<\/strong><\/p>\n\n\n\n<p>(\u8d27\u53f7\uff1a<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/antibody\/product\/Fc-Receptor-Binding-Inhibitor-Antibody-Polyclonal\/14-9161-73?icid=blog\">14-9161-73<\/a>) \u5c01\u95ed\u6548\u679c\u68c0\u6d4b\u56fe\u3002<\/p>\n\n\n\n<p>\u6240\u4ee5\uff0cFc\u53d7\u4f53\u5c01\u95ed\u80fd\u591f\u6709\u6548\u7684\u964d\u4f4e\u7531Fc\u53d7\u4f53\u5bfc\u81f4\u7684\u80cc\u666f\u4fe1\u53f7\u751a\u81f3\u5047\u9633\u6027\u4fe1\u53f7\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03, .wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03[data-kb-block=\"kb-adv-heading1037_9dc1c3-03\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03[data-kb-block=\"kb-adv-heading1037_9dc1c3-03\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading1037_9dc1c3-03[data-kb-block=\"kb-adv-heading1037_9dc1c3-03\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading1037_9dc1c3-03 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading1037_9dc1c3-03\"><br><strong>\u5982\u4f55\u8fdb\u884cFc\u53d7\u4f53\u5c01\u95ed\uff1f<\/strong><\/h2>\n\n\n\n<p>\u7a76\u5176\u6839\u672c\uff0c\u76ee\u524d\u5e38\u7528\u7684Fc\u53d7\u4f53\u5c01\u95ed\u65b9\u6cd5\u662f\u5728\u6d41\u5f0f\u6297\u4f53\u67d3\u8272\u524d\uff0c\u6dfb\u52a0\u5c01\u95ed\u8bd5\u5242\u6765\u4e0eFc\u53d7\u4f53\u7ed3\u5408\u8fdb\u884c\u201c\u5360\u4f4d\u201d\uff0c\u4ece\u800c\u4f7f\u5f97Fc\u53d7\u4f53\u4e27\u5931\u7ed3\u5408\u6d41\u5f0f\u6297\u4f53\u7684\u80fd\u529b\uff0c\u5e38\u89c1\u5c01\u95ed\u8bd5\u5242\u4e3b\u8981\u5305\u62ec\u8840\u6e05\u6216\u8005\u8840\u6e05\u4e2d\u7eaf\u5316\u7684IgG\u3001\u6297CD16\/32\u7684\u6297\u4f53\u4ee5\u53ca\u91cd\u7ec4\u8868\u8fbe\u7684Fc\u3002\u8fd9\u91cc\u5217\u51fa\u4e86Invitrogen eBioscience\u9488\u5bf9\u4e0d\u540c\u79cd\u5c5e\u7ec6\u80de\u8fdb\u884cFc\u53d7\u4f53\u5c01\u95ed\u7684\u4ea7\u54c1\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be, .wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be[data-kb-block=\"kb-adv-heading1037_b699bf-be\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be[data-kb-block=\"kb-adv-heading1037_b699bf-be\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading1037_b699bf-be[data-kb-block=\"kb-adv-heading1037_b699bf-be\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading1037_b699bf-be wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading1037_b699bf-be\">\u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n\n\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1773822793989\"><strong class=\"schema-faq-question\">Fc\u53d7\u4f53\u5c01\u95ed\u5982\u4f55\u64cd\u4f5c\uff1f<\/strong> <p class=\"schema-faq-answer\">\u5177\u4f53\u770b\u5c01\u95ed\u5242\u5382\u5bb6\u7684\u5efa\u8bae\uff0c\u5982\u4f7f\u7528\u6211\u53f8\u7684\u4ea7\u54c1\uff0c\u5728\u6d41\u5f0f\u6297\u4f53\u67d3\u8272\u524d\u8fdb\u884c\u5c01\u95ed\uff0c\u5177\u4f53\u64cd\u4f5c\u5982\u4e0b\u3002\u53e6\u5916\uff0c\u5c01\u95ed\u4e4b\u540e\u4e00\u822c\u65e0\u9700\u6e05\u6d17\u5373\u53ef\u8fdb\u884c\u6d41\u5f0f\u6297\u4f53\u7684\u67d3\u8272\u3002<br \/>\u5c0f\u9f20\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u75280.5-1 \u03bcg\u7eaf\u5316\u7684\u6297\u5c0f\u9f20 CD16\/CD32\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002<br \/>\u4eba\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u752820 \u03bcL\u7eaf\u5316\u7684\u4ebaFc\u53d7\u4f53\u7ed3\u5408\u6291\u5236\u5242\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1773822811327\"><strong class=\"schema-faq-question\">\u5982\u679c\u6211\u7684\u7ec6\u80de\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u662f\u5426\u53ef\u4ee5\u4e0d\u505aFc\u53d7\u4f53\u5c01\u95ed\uff1f<\/strong> <p class=\"schema-faq-answer\">\u662f\u7684\uff0c\u5982\u679c\u786e\u8ba4\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u53ef\u4ee5\u4e0d\u505a\u3002\u5982\u679c\u4e0d\u786e\u5b9a\u7ec6\u80de\u4e0a\u6709\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u5efa\u8bae\u505aFc\u53d7\u4f53\u5c01\u95ed\uff0c\u4ee5\u9632\u4e07\u4e00\u3002<\/p> <\/div> <\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u4ec0\u4e48\u662fFc\u53d7\u4f53\u5c01\u95ed\uff1f \u63d0\u5230Fc\u53d7\u4f53\u5c01\u95ed\uff0c\u9996\u5148\u8981\u5f04\u6e05\u695a\u4ec0\u4e48\u662fFc\u53d7\u4f53\u3002Fc\u53d7\u4f53\u662f\u4e00\u7c7b\u8868\u8fbe\u5728\u67d0\u4e9b\u7ec6\u80de\u6bd4\u5982\u7c92\u7ec6\u80de\u3001B<\/p>\n","protected":false},"author":1847,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[90],"division":[],"class_list":{"0":"post-1037","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-8","7":"tag-90","8":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae\" \/>\n<meta property=\"og:description\" content=\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-18T08:37:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"813\" \/>\n\t<meta property=\"og:image:height\" content=\"587\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Lisa Yao\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lisa Yao\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/\"},\"author\":{\"name\":\"Lisa Yao\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/00c0a91810a7358c7caae4f7bda8c747\"},\"headline\":\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae\",\"datePublished\":\"2026-03-18T08:37:58+00:00\",\"dateModified\":\"2026-04-22T21:59:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/\"},\"wordCount\":167,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/640-1.jpg\",\"keywords\":[\"\u6d41\u5f0f\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#respond\"]}]},{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/\",\"name\":\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/640-1.jpg\",\"datePublished\":\"2026-03-18T08:37:58+00:00\",\"dateModified\":\"2026-04-22T21:59:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/00c0a91810a7358c7caae4f7bda8c747\"},\"description\":\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822793989\"},{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822811327\"}],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/640-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/640-1.jpg\",\"width\":813,\"height\":587},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/00c0a91810a7358c7caae4f7bda8c747\",\"name\":\"Lisa Yao\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"caption\":\"Lisa Yao\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lisa-yaothermofisher-com\\\/\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822793989\",\"position\":1,\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822793989\",\"name\":\"Fc\u53d7\u4f53\u5c01\u95ed\u5982\u4f55\u64cd\u4f5c\uff1f\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5177\u4f53\u770b\u5c01\u95ed\u5242\u5382\u5bb6\u7684\u5efa\u8bae\uff0c\u5982\u4f7f\u7528\u6211\u53f8\u7684\u4ea7\u54c1\uff0c\u5728\u6d41\u5f0f\u6297\u4f53\u67d3\u8272\u524d\u8fdb\u884c\u5c01\u95ed\uff0c\u5177\u4f53\u64cd\u4f5c\u5982\u4e0b\u3002\u53e6\u5916\uff0c\u5c01\u95ed\u4e4b\u540e\u4e00\u822c\u65e0\u9700\u6e05\u6d17\u5373\u53ef\u8fdb\u884c\u6d41\u5f0f\u6297\u4f53\u7684\u67d3\u8272\u3002<br \\\/>\u5c0f\u9f20\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u75280.5-1 \u03bcg\u7eaf\u5316\u7684\u6297\u5c0f\u9f20 CD16\\\/CD32\\\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002<br \\\/>\u4eba\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u752820 \u03bcL\u7eaf\u5316\u7684\u4ebaFc\u53d7\u4f53\u7ed3\u5408\u6291\u5236\u5242\\\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002\",\"inLanguage\":\"zh-Hans\"},\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Question\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822811327\",\"position\":2,\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fc-receptor-blocking-in-flow-cytometry\\\/#faq-question-1773822811327\",\"name\":\"\u5982\u679c\u6211\u7684\u7ec6\u80de\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u662f\u5426\u53ef\u4ee5\u4e0d\u505aFc\u53d7\u4f53\u5c01\u95ed\uff1f\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u662f\u7684\uff0c\u5982\u679c\u786e\u8ba4\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u53ef\u4ee5\u4e0d\u505a\u3002\u5982\u679c\u4e0d\u786e\u5b9a\u7ec6\u80de\u4e0a\u6709\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u5efa\u8bae\u505aFc\u53d7\u4f53\u5c01\u95ed\uff0c\u4ee5\u9632\u4e07\u4e00\u3002\",\"inLanguage\":\"zh-Hans\"},\"inLanguage\":\"zh-Hans\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/","og_locale":"zh_CN","og_type":"article","og_title":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae","og_description":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-18T08:37:58+00:00","article_modified_time":"2026-04-22T21:59:30+00:00","og_image":[{"width":813,"height":587,"url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg","type":"image\/jpeg"}],"author":"Lisa Yao","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Lisa Yao","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/"},"author":{"name":"Lisa Yao","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/00c0a91810a7358c7caae4f7bda8c747"},"headline":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae","datePublished":"2026-03-18T08:37:58+00:00","dateModified":"2026-04-22T21:59:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/"},"wordCount":167,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg","keywords":["\u6d41\u5f0f"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#respond"]}]},{"@type":["WebPage","FAQPage"],"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/","name":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg","datePublished":"2026-03-18T08:37:58+00:00","dateModified":"2026-04-22T21:59:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/00c0a91810a7358c7caae4f7bda8c747"},"description":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u964d\u4f4e\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3001\u51cf\u5c11\u80cc\u666f\u4fe1\u53f7\u548c\u5047\u9633\u6027\u7684\u5e38\u89c1\u6b65\u9aa4\u3002\u672c\u6587\u8bf4\u660e Fc \u53d7\u4f53\u5c01\u95ed\u7684\u539f\u7406\u3001\u4e3a\u4ec0\u4e48\u8981\u505a\u3001\u5982\u4f55\u64cd\u4f5c\uff0c\u4ee5\u53ca\u4eba\u7ec6\u80de\u548c\u5c0f\u9f20\u7ec6\u80de\u7684\u5e38\u89c1\u5904\u7406\u5efa\u8bae\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822793989"},{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822811327"}],"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/640-1.jpg","width":813,"height":587},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"Fc \u53d7\u4f53\u5c01\u95ed\u662f\u4ec0\u4e48\uff1f\u6d41\u5f0f\u7ec6\u80de\u5b9e\u9a8c\u4e2d\u7684\u5fc5\u8981\u6027\u4e0e\u5b9e\u64cd\u5efa\u8bae"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/00c0a91810a7358c7caae4f7bda8c747","name":"Lisa Yao","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","caption":"Lisa Yao"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lisa-yaothermofisher-com\/"},{"@type":"Question","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822793989","position":1,"url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822793989","name":"Fc\u53d7\u4f53\u5c01\u95ed\u5982\u4f55\u64cd\u4f5c\uff1f","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"\u5177\u4f53\u770b\u5c01\u95ed\u5242\u5382\u5bb6\u7684\u5efa\u8bae\uff0c\u5982\u4f7f\u7528\u6211\u53f8\u7684\u4ea7\u54c1\uff0c\u5728\u6d41\u5f0f\u6297\u4f53\u67d3\u8272\u524d\u8fdb\u884c\u5c01\u95ed\uff0c\u5177\u4f53\u64cd\u4f5c\u5982\u4e0b\u3002\u53e6\u5916\uff0c\u5c01\u95ed\u4e4b\u540e\u4e00\u822c\u65e0\u9700\u6e05\u6d17\u5373\u53ef\u8fdb\u884c\u6d41\u5f0f\u6297\u4f53\u7684\u67d3\u8272\u3002<br \/>\u5c0f\u9f20\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u75280.5-1 \u03bcg\u7eaf\u5316\u7684\u6297\u5c0f\u9f20 CD16\/CD32\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002<br \/>\u4eba\u7ec6\u80de\uff1a\u5c06\u7ec6\u80de\u752820 \u03bcL\u7eaf\u5316\u7684\u4ebaFc\u53d7\u4f53\u7ed3\u5408\u6291\u5236\u5242\/100 \u03bcL 2-25\u00b0C\u9884\u5b75\u80b210-20\u5206\u949f\u3002","inLanguage":"zh-Hans"},"inLanguage":"zh-Hans"},{"@type":"Question","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822811327","position":2,"url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fc-receptor-blocking-in-flow-cytometry\/#faq-question-1773822811327","name":"\u5982\u679c\u6211\u7684\u7ec6\u80de\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u662f\u5426\u53ef\u4ee5\u4e0d\u505aFc\u53d7\u4f53\u5c01\u95ed\uff1f","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"\u662f\u7684\uff0c\u5982\u679c\u786e\u8ba4\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u53ef\u4ee5\u4e0d\u505a\u3002\u5982\u679c\u4e0d\u786e\u5b9a\u7ec6\u80de\u4e0a\u6709\u6ca1\u6709Fc\u53d7\u4f53\u8868\u8fbe\uff0c\u5efa\u8bae\u505aFc\u53d7\u4f53\u5c01\u95ed\uff0c\u4ee5\u9632\u4e07\u4e00\u3002","inLanguage":"zh-Hans"},"inLanguage":"zh-Hans"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":90,"label":"\u6d41\u5f0f"}]},"featured_image_src_large":false,"author_info":{"display_name":"Lisa Yao","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lisa-yaothermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":90,"name":"\u6d41\u5f0f","slug":"%e6%b5%81%e5%bc%8f","term_group":0,"term_taxonomy_id":90,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1037","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1847"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1037"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1037\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1037"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1037"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1037"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1037"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}