{"id":1058,"date":"2026-03-24T08:52:12","date_gmt":"2026-03-24T08:52:12","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1058"},"modified":"2026-04-22T21:59:28","modified_gmt":"2026-04-22T21:59:28","slug":"caspase","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/caspase\/","title":{"rendered":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-\u7ec6\u80de\u51cb\u4ea1\u6982\u89c8\"><strong>\u7ec6\u80de\u51cb\u4ea1\u6982\u89c8<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7ec6\u80de\u51cb\u4ea1\u662f\u4e00\u79cd\u7a0b\u5e8f\u6027\u7ec6\u80de\u6b7b\u4ea1\u8fc7\u7a0b\uff0c\u901a\u8fc7\u4e25\u683c\u8c03\u63a7\u7684\u7ec6\u80de\u5185\u4fe1\u53f7\u4f20\u5bfc\u673a\u5236\u6267\u884c\u3002\u8be5\u8fc7\u7a0b\u5bf9\u4e8e\u7ef4\u6301\u7ec4\u7ec7\u7a33\u6001\u548c\u6b63\u5e38\u53d1\u80b2\u81f3\u5173\u91cd\u8981\u3002\u5f02\u5e38\u7684\u7ec6\u80de\u51cb\u4ea1\u673a\u5236\u53ef\u80fd\u5bfc\u81f4\u591a\u79cd\u75be\u75c5\uff0c\u5982\u7ec6\u80de\u51cb\u4ea1\u8fc7\u5ea6\u4f1a\u5f15\u8d77\u795e\u7ecf\u9000\u884c\u6027\u75be\u75c5\uff0c\u800c\u7ec6\u80de\u51cb\u4ea1\u4e0d\u8db3\u5219\u4e0e\u764c\u75c7\u7684\u53d1\u751f\u548c\u53d1\u5c55\u5bc6\u5207\u76f8\u5173\u3002\u5728\u51cb\u4ea1\u8fc7\u7a0b\u4e2d\uff0c\u7ec6\u80de\u4f1a\u7ecf\u5386\u4e00\u7cfb\u5217\u6807\u5fd7\u6027\u4e8b\u4ef6\uff0c\u4ece\u6700\u521d\u7684\u4fe1\u53f7\u63a5\u6536\u5230\u6700\u7ec8\u7684\u7ec6\u80de\u89e3\u4f53\uff0c\u6bcf\u4e00\u6b65\u90fd\u81f3\u5173\u91cd\u8981\u3002\u7406\u89e3\u8fd9\u4e9b\u8fc7\u7a0b\u4e0d\u4ec5\u6709\u52a9\u4e8e\u63ed\u793a\u75be\u75c5\u673a\u5236\uff0c\u8fd8\u80fd\u4e3a\u65b0\u7684\u6cbb\u7597\u65b9\u6cd5\u63d0\u4f9b\u601d\u8def\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"492\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193729@2x-1024x492.png\" alt=\"\" class=\"wp-image-1059\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193729@2x-1024x492.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193729@2x-300x144.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193729@2x-768x369.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193729@2x.png 1224w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe1. \u7ec6\u80de\u51cb\u4ea1\u8fdb\u7a0b\u56fe<sup>[1]<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ec6\u80de\u51cb\u4ea1\u8bf1\u5bfc\u9014\u5f84\"><strong>\u7ec6\u80de\u51cb\u4ea1\u8bf1\u5bfc\u9014\u5f84<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7ec6\u80de\u51cb\u4ea1\u7684\u8bf1\u5bfc\u9014\u5f84\u4e3b\u8981\u5305\u62ec<strong>\u5916\u6e90\u6027\uff08Extrinsic\uff09<\/strong>\u548c<strong>\u5185\u6e90\u6027\uff08Intrinsic\uff09<\/strong>\u4e24\u79cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5916\u6e90\u6027\u9014\u5f84<\/strong>\uff08\u6b7b\u4ea1\u53d7\u4f53\u9014\u5f84\uff09\u7531\u7ec6\u80de\u5916\u90e8\u4fe1\u53f7\u8bf1\u5bfc\uff0c\u901a\u8fc7\u6b7b\u4ea1\u53d7\u4f53\u4ecb\u5bfc\u3002\u5173\u952e\u5206\u5b50\u5305\u62ecFas\u53d7\u4f53\u548c\u80bf\u7624\u574f\u6b7b\u56e0\u5b50\u53d7\u4f53\uff08TNFR\uff09\u3002\u5f53\u914d\u4f53\uff08\u5982FasL\u6216TNF-\u03b1\uff09\u4e0e\u6b7b\u4ea1\u53d7\u4f53\u7ed3\u5408\u65f6\uff0c\u5f62\u6210\u6b7b\u4ea1\u8bf1\u5bfc\u4fe1\u53f7\u590d\u5408\u7269\uff08DISC\uff09\uff0cDISC\u6fc0\u6d3bCaspase-8\uff0c\u968f\u540e\u6fc0\u6d3b\u4e0b\u6e38\u6548\u5e94Caspase\uff08\u5982Caspase-3\uff09\uff0c\u5f15\u53d1\u7ec6\u80de\u51cb\u4ea1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5185\u6e90\u6027\u9014\u5f84<\/strong>\uff08\u7ebf\u7c92\u4f53\u9014\u5f84\uff09\u7531\u7ec6\u80de\u5185\u90e8\u4fe1\u53f7\uff08\u5982DNA\u635f\u4f24\u3001\u6c27\u5316\u5e94\u6fc0\uff09\u8bf1\u5bfc\uff0c\u4e3b\u8981\u901a\u8fc7\u7ebf\u7c92\u4f53\u4ecb\u5bfc\u3002\u5173\u952e\u5206\u5b50\u5305\u62ecBcl-2\u5bb6\u65cf\u86cb\u767d\u8d28\uff08\u5982Bax\u3001Bak\uff09\u3002\u4fc3\u51cb\u4ea1\u4fe1\u53f7\u5bfc\u81f4Bax\/Bak\u5728\u7ebf\u7c92\u4f53\u819c\u4e0a\u805a\u96c6\uff0c\u5f62\u6210\u5b54\u9053\uff0c\u91ca\u653e\u7ec6\u80de\u8272\u7d20c\u3002\u7ec6\u80de\u8272\u7d20c\u4e0eApaf-1\u548cCaspase-9\u5f62\u6210\u51cb\u4ea1\u5c0f\u4f53\uff0c\u6fc0\u6d3bCaspase-9\uff0c\u5e76\u8fdb\u4e00\u6b65\u6fc0\u6d3b\u4e0b\u6e38<strong>\u6548\u5e94Caspase\uff08\u6548\u5e94\u578b\u534a\u80f1\u5929\u51ac\u9176\uff09<\/strong>\uff0c\u6267\u884c\u7ec6\u80de\u51cb\u4ea1\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"692\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x-1024x692.png\" alt=\"\" class=\"wp-image-1060\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x-1024x692.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x-300x203.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x-768x519.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x-96x65.png 96w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193741@2x.png 1222w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe2. \u5185\u6e90\u6027\u9014\u5f84\u548c\u5916\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1<sup>[2]<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-caspase\u68c0\u6d4b\u65b9\u6cd5\"><strong>Caspase\u68c0\u6d4b\u65b9\u6cd5<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f46\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5e38\u7528\u68c0\u6d4b\u65b9\u6cd5\u6839\u636e\u5b9e\u9a8c\u6837\u672c\u7684\u4e0d\u540c\uff0c\u53ef\u4ee5\u5206\u4e3a\u5747\u8d28\u6cd5\u3001FLICA\uff08Fluorochrome-Labeled Inhibitors of Caspases\uff09\u3001\u8367\u5149\u5e95\u7269\u6cd5\u3001\u57fa\u4e8e\u8367\u5149\u5171\u632f\u80fd\u91cf\u8f6c\u79fb\uff08FRET\uff0cFluorescence Resonance Energy Transfer\uff09\u7684\u68c0\u6d4b\u65b9\u6cd5\u4ee5\u53ca\u6297\u4f53\u68c0\u6d4b\u6cd5\uff0c\u8fd9\u4e9b\u65b9\u6cd5\u5e2e\u52a9\u7814\u7a76\u7ec6\u80de\u51cb\u4ea1\u7684\u673a\u5236\u548c\u8fc7\u7a0b\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-cellevent-caspase-3-7\u68c0\u6d4b\u65b9\u6cd5\"><strong>CellEvent Caspase 3\/7\u68c0\u6d4b\u65b9\u6cd5<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">CellEvent Caspase 3\/7\u68c0\u6d4b\u65b9\u6cd5\u57fa\u4e8e\u8367\u5149\u5e95\u7269\u6cd5\uff0c\u5e95\u7269\u4e2d\u5305\u542bDEVD\u80bd\u5e8f\u5217\uff0c\u5f53\u9176\u88ab\u6fc0\u6d3b\u65f6\uff0c\u8be5\u80bd\u5e8f\u5217\u88ab\u5207\u5272\uff0c\u91ca\u653e\u51fa\u5f3a\u8367\u5149\u4fe1\u53f7\u3002\u901a\u8fc7\u68c0\u6d4b\u8367\u5149\u5f3a\u5ea6\u7684\u53d8\u5316\uff0c\u53ef\u4ee5\u8bc4\u4f30Caspase 3\/7\u7684\u6d3b\u6027\u3002\u4e0e\u4f20\u7edfCaspase\u68c0\u6d4b\u65b9\u6cd5\u76f8\u6bd4\uff0c\u8fd9\u79cd\u68c0\u6d4b\u65b9\u6cd5\u5bf9\u7ec6\u80de\u7684\u51cb\u4ea1\u8fc7\u7a0b\u6ca1\u6709\u6291\u5236\u4f5c\u7528\uff0c\u65e0\u9700\u6e05\u6d17\uff0c\u6709\u52a9\u4e8e\u5b9e\u65f6\u76d1\u6d4b\u7ec6\u80de\u51cb\u4ea1\u3002\u5b83\u517c\u5bb9\u6d3b\u7ec6\u80de\u6210\u50cf\u548c\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\uff0c\u64cd\u4f5c\u7b80\u5355\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u5b9e\u9a8c\u9700\u6c42\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"498\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193754@2x-1024x498.png\" alt=\"\" class=\"wp-image-1061\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193754@2x-1024x498.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193754@2x-300x146.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193754@2x-768x373.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193754@2x.png 1226w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe3. CellEvent Caspase3\/7\u68c0\u6d4b\u539f\u7406\u53caWorkflow<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6570\u636e\u5b9e\u4f8b-3\"><strong>\u6570\u636e\u5b9e\u4f8b<sup>[3]<\/sup><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u7814\u7a76\u661f\u5f62\u5b62\u83cc\u7d20\u5bf9\u51cb\u4ea1\u7684\u8bf1\u5bfc\u4f5c\u7528\uff0c\u6211\u4eec\u5bf9HeLa\u7ec6\u80de\u8fdb\u884c\u4e86\u957f\u65f6\u95f4\u7684\u8367\u5149\u76d1\u6d4b\u3002\u6211\u4eec\u5148\u540e\u752850 nM\u7684TMRM\u67d3\u6599\u548c5 \u00b5M\u7684CellEvent\u2122 Caspase-3\/7\u8bd5\u5242\u5bf9HeLa\u7ec6\u80de\u8fdb\u884c\u67d3\u8272\u3002\u968f\u540e\uff0c\u75280.5 \u00b5M\u7684\u661f\u5f62\u5b62\u83cc\u7d20\u5904\u7406\u7ec6\u80de\uff0c\u5e76\u6301\u7eed\u91c7\u96c67\u5c0f\u65f6\u7684\u56fe\u50cf\u3002\u5728\u8fd97\u5c0f\u65f6\u7684\u8fc7\u7a0b\u4e2d\uff0c\u53ef\u4ee5\u660e\u663e\u89c2\u5bdf\u5230\u661f\u5f62\u5b62\u83cc\u7d20\u5f15\u8d77\u7684\u7ebf\u7c92\u4f53\u819c\u7535\u4f4d\u4e27\u5931\u548ccaspase 3\/7\u7684\u6fc0\u6d3b\uff0c\u8fd9\u5206\u522b\u901a\u8fc7TMRM\u4fe1\u53f7\uff08\u7ea2\u8272\uff09\u7684\u51cf\u5c11\u548cCaspase 3\/7\u4fe1\u53f7\uff08\u7eff\u8272\uff09\u7684\u589e\u52a0\u5f97\u4ee5\u663e\u793a\uff08\u89c1\u56fe4\uff09\u3002\u6b64\u5916\uff0c\u7ed3\u5408\u4f7f\u7528CellEvent\u2122 Caspase-3\/7\u548c\u6b7b\u7ec6\u80de\u6838\u9178\u67d3\u6599PI\uff0c\u8fd8\u53ef\u4ee5\u901a\u8fc7\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u51cb\u4ea1\u7ec6\u80de\u7684\u6bd4\u4f8b\uff08\u89c1\u56fe5\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"776\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193803@2x-1024x776.png\" alt=\"\" class=\"wp-image-1062\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193803@2x-1024x776.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193803@2x-300x227.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193803@2x-768x582.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193803@2x.png 1206w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe4. \u661f\u5f62\u5b62\u83cc\u7d20\u8bf1\u5bfc\u7ebf\u7c92\u4f53\u819c\u7535\u4f4d\uff08\u7ea2\uff09\u4e0b\u964d\u548cCaspase 3\/7\uff08\u7eff\uff09\u6fc0\u6d3b\uff0810x\uff0c5 min\/freq.\uff09<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"499\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193813@2x-1024x499.png\" alt=\"\" class=\"wp-image-1063\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193813@2x-1024x499.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193813@2x-300x146.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193813@2x-768x375.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-193813@2x.png 1214w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe5. \u4e0d\u540c\u6d53\u5ea6\uff080 \u00b5M&nbsp;\u5de6\uff0c0.11&nbsp;\u00b5M&nbsp;\u53f3\uff09\u661f\u5f62\u5b62\u83cc\u7d20\u8bf1\u5bfc\u7ec6\u80de\u51cb\u4ea1\u6d41\u5f0f\u56fe<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-faqs\"><strong>FAQs<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q CellEvent Caspase-3\/7 Green Detection Reagent\u53ef\u4ee5\u7528\u4e8e\u56fa\u5b9a\u6837\u672c\u5417\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u4e0d\u53ef\u4ee5\uff0c\u8be5\u8bd5\u5242\u9002\u7528\u4e8e\u6d3b\u7ec6\u80de\u67d3\u8272\uff0c\u67d3\u8272\u540e\u53ef\u4ee5\u7528\u7532\u919b\u56fa\u5b9a\uff0c\u4e0d\u80fd\u76f4\u63a5\u67d3\u56fa\u5b9a\u6837\u672c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q CellEvent Caspase-3\/7 Green Detection Reagent\u67d3\u8272\u540e\u8fd8\u80fd\u505a\u514d\u75ab\u8367\u5149\u5b9e\u9a8c\u5417\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u53ef\u4ee5\uff0c\u63a8\u8350\u5148\u8fdb\u884c\u7ec6\u80de\u8868\u9762\u67d3\u8272\u548c\u672c\u4ea7\u54c1\u7684\u67d3\u8272\uff0c\u56fa\u5b9a\u540e\u518d\u8fdb\u884c\u5176\u4ed6\u7ec6\u80de\u5185\u7684\u67d3\u8272\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u8d44\u6599\u4e0e\u6587\u732e\">\u53c2\u8003\u8d44\u6599\u4e0e\u6587\u732e\uff1a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp;Invitrogen \u7ec6\u80de\u529f\u80fd\u5206\u6790\u4ea7\u54c1\u9009\u62e9\u6307\u5357<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2.&nbsp;Yuan, J., &amp; Ofengeim, D. (2024). A guide to cell death pathways.&nbsp;Nature Reviews Molecular Cell Biology,&nbsp;25(5), 379-395.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"h-\">3.&nbsp;\u201c\u51cb\u4ea1\u4f7f\u8005-Caspase\u5728\u51cb\u4ea1\u5206\u6790\u4e2d\u7684\u5e94\u7528\u201d \u8d5b\u9ed8\u98deCOT\u8bfe\u7a0b<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7ec6\u80de\u51cb\u4ea1\u6982\u89c8 \u7ec6\u80de\u51cb\u4ea1\u662f\u4e00\u79cd\u7a0b\u5e8f\u6027\u7ec6\u80de\u6b7b\u4ea1\u8fc7\u7a0b\uff0c\u901a\u8fc7\u4e25\u683c\u8c03\u63a7\u7684\u7ec6\u80de\u5185\u4fe1\u53f7\u4f20\u5bfc\u673a\u5236\u6267\u884c\u3002\u8be5\u8fc7\u7a0b\u5bf9\u4e8e\u7ef4\u6301\u7ec4\u7ec7\u7a33\u6001\u548c<\/p>\n","protected":false},"author":1852,"featured_media":1124,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[108,109],"division":[9],"class_list":["post-1058","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-caspase","tag-109","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf\" \/>\n<meta property=\"og:description\" content=\"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T08:52:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1224\" \/>\n\t<meta property=\"og:image:height\" content=\"588\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf\",\"datePublished\":\"2026-03-24T08:52:12+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/\"},\"wordCount\":112,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2-1.png\",\"keywords\":[\"Caspase\",\"\u7ec6\u80de\u51cb\u4ea1\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/\",\"name\":\"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2-1.png\",\"datePublished\":\"2026-03-24T08:52:12+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\\\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\\\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2-1.png\",\"width\":1224,\"height\":588},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/caspase\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/","og_locale":"zh_CN","og_type":"article","og_title":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf","og_description":"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-24T08:52:12+00:00","article_modified_time":"2026-04-22T21:59:28+00:00","og_image":[{"width":1224,"height":588,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/caspase\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf","datePublished":"2026-03-24T08:52:12+00:00","dateModified":"2026-04-22T21:59:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/caspase\/"},"wordCount":112,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png","keywords":["Caspase","\u7ec6\u80de\u51cb\u4ea1"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/caspase\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/","name":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png","datePublished":"2026-03-24T08:52:12+00:00","dateModified":"2026-04-22T21:59:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u65e0\u8bba\u5916\u6e90\u6216\u662f\u5185\u6e90\u6027\u9014\u5f84\u7ec6\u80de\u51cb\u4ea1\uff0c\u4e8c\u8005\u5747\u901a\u8fc7\u6fc0\u6d3b\u6548\u5e94Caspase\u542f\u52a8\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\uff0c\u6548\u5e94Caspase\u662f\u53c2\u4e0e\u7ec6\u80de\u51cb\u4ea1\u8fc7\u7a0b\u7684\u5173\u952e\u9176\u7c7b\uff0c\u4e3b\u8981\u5305\u62ecCaspase 3\/7\uff0c\u56e0\u6b64\uff0c\u68c0\u6d4bCaspase 3\/7\u7684\u6d3b\u6027\u5bf9\u786e\u8ba4\u7ec6\u80de\u662f\u5426\u53d1\u751f\u51cb\u4ea1\u3001\u836f\u7269\u7b5b\u9009\u548c\u75be\u75c5\u7814\u7a76\u975e\u5e38\u91cd\u8981\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1.png","width":1224,"height":588},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/caspase\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u89e3\u8c1c\u7ec6\u80de\u51cb\u4ea1-Caspase\u7684\u795e\u79d8\u529b\u91cf"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":108,"label":"Caspase"},{"value":109,"label":"\u7ec6\u80de\u51cb\u4ea1"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1-1024x492.png",760,365,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":3,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":108,"name":"Caspase","slug":"caspase","term_group":0,"term_taxonomy_id":108,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":109,"name":"\u7ec6\u80de\u51cb\u4ea1","slug":"%e7%bb%86%e8%83%9e%e5%87%8b%e4%ba%a1","term_group":0,"term_taxonomy_id":109,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1058","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1058"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1058\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1124"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1058"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1058"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1058"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1058"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}