{"id":1085,"date":"2026-03-20T08:32:24","date_gmt":"2026-03-20T08:32:24","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1085"},"modified":"2026-04-22T21:59:28","modified_gmt":"2026-04-22T21:59:28","slug":"t-cell-activation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/t-cell-activation\/","title":{"rendered":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">T\u7ec6\u80de\u6fc0\u6d3b\u662f\u4f53\u5916\u83b7\u53d6\u5927\u91cfT\u6dcb\u5df4\u7ec6\u80de\u57fa\u7840\u7684\u5b9e\u9a8c\u624b\u6bb5\u4e4b\u4e00\uff0c\u6fc0\u6d3b\u548c\u6269\u589e\u83b7\u5f97\u7684T\u7ec6\u80de\u53ef\u5e7f\u6cdb\u5e94\u7528\u4e8e\u4e0b\u6e38CAR-T\u3001TCR-T\u7b49\u7814\u7a76\u548c\u6cbb\u7597\u3002\u751f\u7406\u72b6\u6001\u4e0b\uff0cTCR\uff08T\u7ec6\u80de\u53d7\u4f53\uff09\u4f1a\u4e0eCD3\u03b3, \u03b5, \u03c3\u548c\u03b6\u5f62\u6210\u4e00\u4e2a\u5927\u7684\u590d\u5408\u7269 (\u56fe1)\u3002\u53d1\u751f\u6297\u539f\u63d0\u5448\u65f6\uff0c\u6b64\u590d\u5408\u7269\u53ef\u80fd\u53d1\u751f\u805a\u96c6\u3001\u6392\u963b\u53bb\u78f7\u9178\u5316\u7684\u5206\u5b50 \u3001\u52df\u96c6Lck\uff08\u6dcb\u5df4\u7ec6\u80de\u7279\u5f02\u6027\u86cb\u767d\u916a\u6c28\u9178\u6fc0\u9176\uff09\u4ee5\u53ca\u91ca\u653e\u51fa\u5305\u57cb\u5728\u819c\u5185\u7684CD3\u03b6\u5206\u5b50\u7b49\uff0c\u8fdb\u800c\u523a\u6fc0T\u7ec6\u80de\u6d3b\u5316\u548c\u589e\u6b96\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"565\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211025@2x-1024x565.png\" alt=\"\" class=\"wp-image-1086\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211025@2x-1024x565.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211025@2x-300x166.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211025@2x-768x424.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211025@2x.png 1094w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe1. T \u7ec6\u80de\u4fe1\u53f7\u8f6c\u5bfc\u7684\u6b63\u5411\u8c03\u8282<sup>[1]<\/sup><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7531\u4e8eCD3\u03b5\u4e9a\u57fa\u5728T\u7ec6\u80de\u8868\u9762\u76f8\u5bf9\u5bb9\u6613\u88ab\u6297\u4f53\u8bc6\u522b\u548c\u7ed3\u5408\uff0c\u56e0\u6b64\u5546\u54c1\u5316\u7684T\u7ec6\u80de\u6fc0\u6d3b\u6297\u4f53\u5927\u591a\u662f\u9488\u5bf9CD3\u03b5\u4e9a\u57fa\u7684\u3002\u4e0e\u6297\u539f\u63d0\u5448\u8fc7\u7a0b\u7c7b\u4f3c\uff0c\u5728\u4f53\u5916\u5b9e\u9a8c\u4e2d\uff0c\u4f7f\u7528CD3\u03b5\u7684\u6297\u4f53\uff0c\u53ef\u4ee5\u6709\u6548\u5730\u6a21\u62df\u6297\u539f-MHC\u590d\u5408\u7269\u4e0eTCR\u7684\u7ed3\u5408\uff0c\u4ece\u800c\u6fc0\u6d3b\u4e0b\u6e38\u7684\u4fe1\u53f7\u4f20\u5bfc\u901a\u8def\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9664\u4e86CD3\u6784\u8c61\u6539\u53d8\u5f15\u8d77\u7684\u7b2c\u4e00\u4fe1\u53f7\uff0c<strong>T\u7ec6\u80de\u7684\u5b8c\u5168\u6d3b\u5316\u8fd8\u9700\u8981\u53e6\u4e00\u4e2a\u5171\u523a\u6fc0\u4fe1\u53f7\uff08CD28\u4ecb\u5bfc\u7684\u7b2c\u4e8c\u4fe1\u53f7\uff09<\/strong>\u3002\u5b83\u901a\u5e38\u4e0e\u6297\u539f\u63d0\u5448\u7ec6\u80de\u8868\u9762\u7684CD80\/CD86\u5206\u5b50\u4f5c\u7528\uff0c\u5f53\u7136\u4e5f\u53ef\u4ee5\u7528CD28\u6297\u4f53\u4ee3\u66ffCD80\/CD86\u6765\u8bf1\u53d1\u7b2c\u4e8c\u4fe1\u53f7\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"393\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211038@2x-1024x393.png\" alt=\"\" class=\"wp-image-1087\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211038@2x-1024x393.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211038@2x-300x115.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211038@2x-768x295.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211038@2x.png 1078w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe2. T \u7ec6\u80de\u523a\u6fc0<sup>[2]<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-cd3-cd28\u6297\u4f53\u6d3b\u5316t\u7ec6\u80de\u64cd\u4f5c\u6b65\u9aa4\"><strong>CD3\/CD28\u6297\u4f53\u6d3b\u5316T\u7ec6\u80de\u64cd\u4f5c\u6b65\u9aa4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u91cc\u4ee5\u6fc0\u6d3b\u5c0f\u9f20\u813e\u810f\u6dcb\u5df4\u7ec6\u80de\u4e3a\u4f8b<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6b65\u9aa4-i-\u6297\u4f53\u5305\u88ab96\u5b54\u677f\"><strong>\u6b65\u9aa4 I\uff1a\u6297\u4f53\u5305\u88ab96\u5b54\u677f<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u5728\u65e0\u83cc PBS \u4e2d\u5236\u5907 5-10 \u00b5g\/mL anti-CD3\uff08\u8d27\u53f7#16-0031-82\uff09\u6eb6\u6db2\u3002Note\uff1a\u5efa\u8bae\u8fdb\u884c\u9884\u5b9e\u9a8c\uff0c\u4ee5\u786e\u5b9a\u5176\u4ed6\u6d53\u5ea6CD3\u6297\u4f53\u8bf1\u5bfc\u7ec6\u80de\u6d3b\u5316\u7684\u529f\u6548\u3002<\/li>\n\n\n\n<li>\u5c06 50 \u00b5L \u6297\u4f53\u6eb6\u6db2\u5206\u914d\u523096 \u5b54\u677f\u5404\u5b54\u4e2d\u3002\u5bf9\u4e8e\u672a\u523a\u6fc0\u7684\u5bf9\u7167\u5b54\uff0c\u6dfb\u52a0 50 \u00b5L \u65e0\u83cc PBS\u3002<\/li>\n\n\n\n<li>\u5c01\u53e3\u819c\u5bc6\u5c0196\u5b54\u677f\u4ee5\u907f\u514d\u6db2\u4f53\u84b8\u53d1\uff0c37\u00b0C\u4e0b\u5b75\u80b22 h\uff0c\u6216\u63d0\u524d\u4e00\u5929\u51c6\u5907\u5e76\u5728 4\u00b0C \u4e0b\u4fdd\u5b58\u8fc7\u591c\u3002<\/li>\n\n\n\n<li>\u6dfb\u52a0\u7ec6\u80de\u4e4b\u524d\uff0c\u53d6\u51fa50 \u00b5L\u6297\u4f53\u6eb6\u6db2\u3002<\/li>\n\n\n\n<li>\u7528 200 \u00b5L \u65e0\u83cc PBS \u51b2\u6d17\u6bcf\u4e2a\u5b54\u5e76\u4e22\u5f03 PBS\u3002<\/li>\n\n\n\n<li>\u91cd\u590d\u4e0a\u8ff0\u6b65\u9aa4\u3002<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6b65\u9aa4-ii-\u6dfb\u52a0\u7ec6\u80de\"><strong>\u6b65\u9aa4 II\uff1a\u6dfb\u52a0\u7ec6\u80de<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u5c06\u51c6\u5907\u597d\u7684\u7ec6\u80de\u7528\u5b8c\u5168\u57f9\u517b\u57fa\u91cd\u60ac\u4e3a1-2&#215;10<sup>6<\/sup>\/mL\u3002Note\uff1a\u5efa\u8bae\u6ef4\u5b9a\u7ec6\u80de\u5bc6\u5ea6\uff082-3&#215;10<sup>6<\/sup>\u7ec6\u80de\/mL\u81f310<sup>5<\/sup>\u7ec6\u80de\/mL\uff09\u4ee5\u5b9e\u73b0\u6700\u4f73\u6d3b\u5316\u3002<\/li>\n\n\n\n<li>\u7528 PBS \u6e05\u6d17\u5b54\u540e\uff08\u4e0a\u8ff0\u6b65\u9aa4 6\uff09\uff0c\u5411\u6bcf\u4e2a\u5b54\u4e2d\u6dfb\u52a0 100 \u00b5L \u7ec6\u80de\u60ac\u6d6e\u6db2\uff08\u4e0d\u540c\u6761\u4ef6\u6ce8\u610f\u8bbe\u7f6e\u590d\u5b54\uff09\u3002<\/li>\n\n\n\n<li>\u6dfb\u52a0CD28\u6297\u4f53\uff08\u8d27\u53f7#16-0281-82\uff09\uff0c\u4f7f\u5176\u7ec8\u6d53\u5ea6\u4e3a 2 ug\/mL\u3002<\/li>\n\n\n\n<li>\u653e\u5165 37\u00b0C\u30015% CO<sub>2<\/sub>&nbsp;\u57f9\u517b\u7bb1\u4e2d\uff0c\u5b75\u80b2 2-4\u5929\u3002Note\uff1a\u5b75\u80b2\u65f6\u95f4\u9700\u8981\u6839\u636e\u5b9e\u9a8c\u9700\u6c42\u8fdb\u884c\u4f18\u5316\uff0c\u6ce8\u610f\u89c2\u5bdf\u7ec6\u80de\u72b6\u6001\u548c\u57f9\u517b\u57fa\u989c\u8272\uff0c\u53ca\u65f6\u66f4\u6362\u65b0\u9c9c\u57f9\u517b\u57fa\u3002<\/li>\n\n\n\n<li>\u6536\u83b7\u548c\u5904\u7406\u7ec6\u80de\u8fdb\u884c\u4e0b\u6e38\u68c0\u6d4b\u3002<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-question-amp-answer\"><strong>Question &amp; Answer<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u4e0a\u8ff0\u6297\u4f53\u523a\u6fc0\u65b9\u6848\u53ef\u4ee5\u5c06T\u7ec6\u80de\u6269\u589e\u591a\u5c11\u500d\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A \u4e00\u822c\u6765\u8bb2\uff0c\u81f3\u5c11\u51e0\u5341\u500d\u7684\u6269\u589e\u500d\u6570\u662f\u53ef\u4ee5\u5b9e\u73b0\u7684\u3002\u4f46\u8fd9\u540c\u65f6\u4e5f\u4e0e\u7ec6\u80de\u6765\u6e90\u3001\u72b6\u6001\uff0c\u4ee5\u53ca\u6297\u4f53\u6d53\u5ea6\u548c\u6fc0\u6d3b\u65f6\u95f4\u606f\u606f\u76f8\u5173\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u6297\u539f\u63d0\u5448\u7684\u65b9\u6cd5\u4e0e\u7528CD3\/CD28\u6297\u4f53\u6d3b\u5316\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u5229\u7528\u6297\u539f\u63d0\u5448\u65b9\u6cd5\u6d3b\u5316\u7684T\u7ec6\u80de\u662f\u67d0\u4e2a\u6297\u539f\u7279\u5f02\u6027\u7684\u7ec6\u80de\uff0c\u8fd9\u90e8\u5206\u7ec6\u80de\u6bd4\u4f8b\u504f\u4f4e\uff0c\u800cCD3\/CD28\u6d3b\u5316\u7684T\u7ec6\u80de\u662f\u591a\u514b\u9686\u7684\uff0c\u4ece\u800c\u80fd\u591f\u83b7\u5f97\u8f83\u591a\u7684T\u7ec6\u80de\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u5728\u4ec0\u4e48\u65f6\u95f4\u8be5\u7ed9T\u7ec6\u80de\u8fdb\u884c\u8865\u6db2\u6216\u8005\u6362\u6db2\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u6fc0\u6d3b\u8fc7\u7a0b\u4e2d\uff0c\u9700\u6bcf\u5929\u89c2\u5bdf\u7ec6\u80de\u662f\u5426\u5f62\u6210\u514b\u9686\u56e2\u3002\u53ef\u4ee5\u5bf9\u7ec6\u80de\u8fdb\u884c\u8ba1\u6570\uff0c\u5982\u679c\u51fa\u73b0\u57f9\u517b\u57fa\u53d8\u9ec4\u6216\u7ec6\u80de\u5bc6\u5ea6\u8fc7\u9ad8\u7684\u60c5\u51b5\uff0c\u53ef\u5439\u6563\u7ec6\u80de\u514b\u9686\u56e2\u540e\u8c03\u6574\u7ec6\u80de\u5bc6\u5ea6\u81f30.5-1\u00d710<sup>6<\/sup>\/ml\uff0c\u79bb\u5fc3\u91cd\u60ac\u5728\u65b0\u9c9c\u57f9\u517b\u57fa\u4e2d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u5982\u679c\u6211\u9700\u8981\u89c2\u5bdfT\u7ec6\u80de\u589e\u6b96\u80fd\u529b\uff0c\u6709\u54ea\u4e9b\u65b9\u6848\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u53ef\u4ee5\u91c7\u7528\u7ec6\u80de\u8ba1\u6570\u7684\u65b9\u6cd5\uff0c\u4e5f\u53ef\u4ee5\u5229\u7528\u67d3\u6599\u7a00\u91ca\u6cd5\u89c2\u5bdfT\u7ec6\u80de\u7684\u589e\u6b96\u4ee3\u6570\uff0c\u63a8\u8350\u4f7f\u7528CellTrace\u7ec6\u80de\u589e\u6b96\u68c0\u6d4b\u8bd5\u5242\uff08\u4f8b\u5982Celltrace CFSE\uff0c\u8d27\u53f7C34554\uff09\uff0c\u6b64\u5916\u5229\u7528Click-it EdU\u7684\u65b9\u6cd5\u4e5f\u53ef\u4ee5\u68c0\u6d4b\u4e0d\u540c\u523a\u6fc0\u6761\u4ef6\u4e0bT\u7ec6\u80de\u7684\u589e\u6b96\u80fd\u529b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q CD3\/CD28\u78c1\u73e0\u6fc0\u6d3b\u4e0eCD3\/CD28\u6297\u4f53\u6fc0\u6d3bT\u7ec6\u80de\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u78c1\u73e0\u63d0\u4f9b\u4e86\u591a\u4ef7\u4ea4\u8054\u4fe1\u53f7\uff0c\u901a\u5e38\u6fc0\u6d3b\u5f3a\u5ea6\u8f83\u9ad8\u4e14\u6301\u7eed\u65f6\u95f4\u8f83\u957f\uff0c\u80fd\u591f\u66f4\u6709\u6548\u5730\u6a21\u62df\u5929\u7136APC\u7684\u4f5c\u7528\uff0c\u4f46\u4ef7\u683c\u8f83\u9ad8\uff0c\u5e38\u7528\u4e8e\u9700\u8981\u9ad8\u6548\u6fc0\u6d3bT\u7ec6\u80de\u7684\u5b9e\u9a8c\uff1b\u6297\u4f53\u6fc0\u6d3b\u7684\u64cd\u4f5c\u76f8\u5bf9\u7b80\u5355\uff0c\u6fc0\u6d3b\u5f3a\u5ea6\u548c\u6301\u7eed\u65f6\u95f4\u53ef\u80fd\u76f8\u5bf9\u8f83\u5f31\uff0c\u9002\u7528\u4e8e\u4e00\u822c\u7684T\u7ec6\u80de\u6fc0\u6d3b\u5b9e\u9a8c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5176\u4ed6\u53ef\u53c2\u8003\u7684t\u7ec6\u80de\u523a\u6fc0\u6d3b\u5316\u65b9\u6cd5-3\"><strong>\u5176\u4ed6\u53ef\u53c2\u8003\u7684T\u7ec6\u80de\u523a\u6fc0\u6d3b\u5316\u65b9\u6cd5<sup>[3]<\/sup><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"467\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211056@2x-1024x467.png\" alt=\"\" class=\"wp-image-1088\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211056@2x-1024x467.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211056@2x-300x137.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211056@2x-768x350.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211056@2x.png 1092w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*ConA\u548cPHA \u4f5c\u7528\u673a\u5236\u7c7b\u4f3c\uff0c\u4e24\u8005\u53ef\u4ee5\u7ed3\u5408\u7ec6\u80de\u819c\u86cb\u767d\u4e0a\u7684\u7cd6\u57fa\u57fa\u56e2\uff0c\u8bf1\u53d1T\u7ec6\u80de\u53d7\u4f53\u7684\u4ea4\u8054\uff0c\u4ece\u800c\u6fc0\u6d3bT\u7ec6\u80de\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*\u8f85\u52a9\u7ec6\u80de\uff1a\u4e0eAPC\u7ec6\u80de\u529f\u80fd\u7c7b\u4f3c\uff0c\u4e3aT\u7ec6\u80de\u6fc0\u6d3b\u63d0\u4f9b\u5171\u523a\u6fc0\u5206\u5b50\u6216\u8005Fc\u53d7\u4f53\uff08\u53ef\u63d0\u4f9b\u6297\u4f53\u7ed3\u5408\u4f4d\u70b9\uff09\u3002\u7ec6\u80de\u6765\u6e90\u53ef\u4ee5\u662f\u5220\u9664\u6216\u672a\u5220\u9664T\u7ec6\u80de\u7684\u5176\u4ed6\u514d\u75ab\u7ec6\u80de\u7ec4\u5206\u3002\u4e3a\u907f\u514d\u8f85\u52a9\u7ec6\u80de\u7684\u80cc\u666f\u589e\u6b96\uff0c\u53ef\u4ee5\u7528\u7ec6\u80de\u8272\u7d20C\u6216\u8005\u03b3\u5c04\u7ebf\u8fdb\u884c\u5904\u7406\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u6587\u732e\">\u53c2\u8003\u6587\u732e\uff1a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">[1] K Shah, K., Al-Haidari, A., Sun, J., &amp; Kazi, J. U. (2021). T cell receptor (TCR) signaling in health and disease. Signal transduction and targeted therapy, 6(1), 412. doi: 10.1038\/s41392-021-00823-w.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] Cappell, K. M., &amp; Kochenderfer, J. N. (2021). A comparison of chimeric antigen receptors containing CD28 versus 4-1BB costimulatory domains.&nbsp;Nature reviews Clinical oncology, 18(11), 715-727. doi: 10.1038\/s41571-021-00530-z<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3] Kruisbeek, A. M., Shevach, E., &amp; Thornton, A. M. (2004). Proliferative Assays for T Cell Function. Current Protocols in Immunology.&nbsp;doi:10.1002\/0471142735.im0312s60<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>T\u7ec6\u80de\u6fc0\u6d3b\u662f\u4f53\u5916\u83b7\u53d6\u5927\u91cfT\u6dcb\u5df4\u7ec6\u80de\u57fa\u7840\u7684\u5b9e\u9a8c\u624b\u6bb5\u4e4b\u4e00\uff0c\u6fc0\u6d3b\u548c\u6269\u589e\u83b7\u5f97\u7684T\u7ec6\u80de\u53ef\u5e7f\u6cdb\u5e94\u7528\u4e8e\u4e0b\u6e38CAR-T\u3001TCR<\/p>\n","protected":false},"author":1852,"featured_media":1122,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[107],"division":[9],"class_list":["post-1085","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-t","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-20T08:32:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1094\" \/>\n\t<meta property=\"og:image:height\" content=\"604\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01\",\"datePublished\":\"2026-03-20T08:32:24+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/\"},\"wordCount\":208,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/4.png\",\"keywords\":[\"T\u7ec6\u80de\u6fc0\u6d3b\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/\",\"name\":\"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/4.png\",\"datePublished\":\"2026-03-20T08:32:24+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/4.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/4.png\",\"width\":1094,\"height\":604},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/t-cell-activation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/","og_locale":"zh_CN","og_type":"article","og_title":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01","og_description":"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-20T08:32:24+00:00","article_modified_time":"2026-04-22T21:59:28+00:00","og_image":[{"width":1094,"height":604,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/t-cell-activation\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01","datePublished":"2026-03-20T08:32:24+00:00","dateModified":"2026-04-22T21:59:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/t-cell-activation\/"},"wordCount":208,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png","keywords":["T\u7ec6\u80de\u6fc0\u6d3b"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/t-cell-activation\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/","name":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png","datePublished":"2026-03-20T08:32:24+00:00","dateModified":"2026-04-22T21:59:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u672c\u6587\u56f4\u7ed5 T \u7ec6\u80de\u4f53\u5916\u6fc0\u6d3b\u4e0e\u6269\u589e\u8fd9\u4e00\u57fa\u7840\u4e14\u5173\u952e\u7684\u514d\u75ab\u5b66\u5b9e\u9a8c\u6280\u672f\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\uff0c\u9610\u660e\u5176\u4f5c\u4e3a CAR\u2011T\u3001TCR\u2011T \u7b49\u7ec6\u80de\u6cbb\u7597\u4e0e\u76f8\u5173\u7814\u7a76\u4e0a\u6e38\u6838\u5fc3\u6b65\u9aa4\u7684\u91cd\u8981\u5730\u4f4d\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4.png","width":1094,"height":604},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/t-cell-activation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"T\u7ec6\u80de\u6fc0\u6d3b\u7684\u79d8\u7c4d\uff0c\u6d41\u5f0f\u5fc5\u770b\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":107,"label":"T\u7ec6\u80de\u6fc0\u6d3b"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/4-1024x565.png",760,419,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":107,"name":"T\u7ec6\u80de\u6fc0\u6d3b","slug":"t%e7%bb%86%e8%83%9e%e6%bf%80%e6%b4%bb","term_group":0,"term_taxonomy_id":107,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1085","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1085"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1085\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1122"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1085"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1085"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1085"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1085"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}