{"id":1090,"date":"2026-03-20T06:16:43","date_gmt":"2026-03-20T06:16:43","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1090"},"modified":"2026-04-22T21:59:29","modified_gmt":"2026-04-22T21:59:29","slug":"ic-fixation-buffer","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/","title":{"rendered":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u5bf9\u7ec6\u80de\u5185\u7684\u86cb\u767d\u9776\u6807\u67d3\u8272\uff0c\u5f80\u5f80\u9700\u8981\u7528\u5230\u56fa\u5b9a\u5242\u548c\u7834\u819c\u5242\uff0c\u5176\u76ee\u7684\u662f\u4e3a\u4e86\u56fa\u5b9a\u7ec6\u80de\u5e76\u7ed9\u7ec6\u80de\u819c\u7a7f\u5b54\uff0c\u4ee5\u4fbf\u8fdb\u884c\u540e\u7eed\u7684\u67d3\u8272\u548c\u5206\u6790\u3002\u8fd9\u6837\u53ef\u4ee5\u4fdd\u6301\u7ec6\u80de\u7684\u5f62\u6001\u5b8c\u6574\u6027\uff0c\u4f7f\u5f97\u7ec6\u80de\u5185\u7684\u76ee\u6807\u86cb\u767d\u80fd\u591f\u66b4\u9732\u51fa\u6765\uff0c\u65b9\u4fbf\u67d3\u8272\u548c\u5206\u6790\uff0c\u5e76\u4e14\u80fd\u591f\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u8fdb\u4e00\u6b65\u7814\u7a76\u548c\u5206\u6790\u3002\u4f7f\u7528\u5408\u9002\u7684\u56fa\u5b9a\u7834\u819c\u5242\uff0c\u53ef\u4ee5\u5728\u56fa\u5b9a\u7834\u819c\u7684\u540c\u65f6\u4fdd\u7559\u7ec6\u80de\u819c\u86cb\u767d\u4e0a\u7ed3\u5408\u7684\u8367\u5149\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">eBioscience\u2122 \u6d41\u5f0f\u80de\u5185\u56fa\u5b9a\u7834\u819c\u7f13\u51b2\u6db2\u4e3b\u8981\u5305\u542b\u4e24\u4e2a\u7ec4\u5206\uff1aIntracellular Fixation Buffer\uff0c125 mL\uff08\u5355\u72ec\u8d27\u53f7<a href=\"https:\/\/www.thermofisher.cn\/order\/catalog\/product\/00-8222-49?icid=cn-blog-bid\">00-8222-49<\/a>\uff09\uff0cPermeabilization Buffer\uff0810x\uff09\uff0c100 mL\uff08\u5355\u72ec\u8d27\u53f7 00-8333-56\uff09<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1020\" height=\"536\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211611@2x.png\" alt=\"\" class=\"wp-image-1092\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211611@2x.png 1020w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211611@2x-300x158.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211611@2x-768x404.png 768w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8bd5\u5242\u914d\u7f6e\"><strong>\u8bd5\u5242\u914d\u7f6e<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Intracellular Fixation Buffer\uff1a\u901a\u5e38\u662f2X\uff0c\u53ef\u76f4\u63a5\u7b49\u4f53\u79ef\u52a0\u5165\u5f85\u56fa\u5b9a\u7684\u7ec6\u80de\u4f53\u7cfb\u4e2d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Permeabilization Buffer\uff1a\u4ea7\u54c1\u4e3a10X\uff0c\u9700\u8981\u4f7f\u7528\u53bb\u79bb\u5b50\u6c34\u7a00\u91ca\u81f31X\u4f7f\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u8fd9\u91cc\u63d0\u9192\u5927\u5bb6\u7684\u662f\uff0c\u68c0\u6d4b\u7ec6\u80de\u6838\u5185\u7684\u56e0\u5b50\u5efa\u8bae\u4f7f\u7528eBioscience\u2122 Foxp3\/\u8f6c\u5f55\u56e0\u5b50\u6d41\u5f0f\u56fa\u5b9a\u7834\u819c\u7f13\u51b2\u6db2\uff08\u8d27\u53f7<a href=\"https:\/\/www.thermofisher.cn\/order\/catalog\/product\/00-5523-00?icid=cn-blog-bid\">00-5523-00<\/a>\uff09\uff0c\u540e\u7eed\u6211\u4eec\u4e5f\u4f1a\u4ecb\u7ecd\u5173\u4e8e\u8be5\u4ea7\u54c1\u7684\u4f7f\u7528\u65b9\u6cd5\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9e\u9a8c\u6b65\u9aa4\"><strong>\u5b9e\u9a8c\u6b65\u9aa4<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u672c\u5b9e\u9a8c\u65b9\u6848\u662f\u4ee51-5ml-ep\u7ba1\u4e3a\u4f8b\"><strong>\u672c\u5b9e\u9a8c\u65b9\u6848\u662f\u4ee51.5mL EP\u7ba1\u4e3a\u4f8b<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1. [\u53ef\u9009]\u6839\u636e\u9700\u8981\u68c0\u6d4b\u7684\u80de\u5185\u86cb\u767d\uff0c\u9009\u62e9\u5408\u9002\u7684\u523a\u6fc0\u6761\u4ef6\u5bf9\u7ec6\u80de\u8fdb\u884c\u9884\u5904\u7406\u3002\u70b9\u51fb\u5b9e\u9a8c\u6b65\u9aa4\u6700\u540e\u7684\u5f80\u671f\u5185\u5bb9\uff1a\u7ec6\u80de\u56e0\u5b50\u6d41\u5f0f\u5b9e\u9a8c\u65b9\u6cd5\uff0c\u4e86\u89e3\u66f4\u591a\u3002<br>2. \u5236\u5907\u5355\u7ec6\u80de\u60ac\u6db2\uff0c\u5c06\u51c6\u5907\u597d\u768410^6\u4e2a\u7ec6\u80de\u7f6e\u4e8e100 \u03bcL PBS\u4e2d\u3002<br>3. [\u53ef\u9009]\u6839\u636e\u6837\u672c\u79cd\u5c5e\u53ca\u6765\u6e90\u9009\u62e9\u5408\u9002\u7684Fc\u53d7\u4f53\u5242\u8fdb\u884c\u5c01\u95ed\u3002\u70b9\u51fb\u5b9e\u9a8c\u6b65\u9aa4\u6700\u540e\u7684\u5f80\u671f\u5185\u5bb9\uff1a\u5c01\u95edFc\u53d7\u4f53\uff0c\u4e86\u89e3\u66f4\u591a\u3002<br>4. [\u53ef\u9009]\u4f7f\u7528\u53ef\u56fa\u5b9a\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u5bf9\u7ec6\u80de\u8fdb\u884c\u67d3\u8272\uff1a\u4f7f\u75281 mL PBS\u91cd\u60ac\u7ec6\u80de\uff0c\u5411\u5176\u4e2d\u52a0\u51651 \u03bcL\u53ef\u56fa\u5b9a\u6b7b\u6d3b\u67d3\u6599\uff0c\u6df7\u5408\u5747\u5300\u540e4\u00b0C\u907f\u5149\u5b75\u80b230 min\u3002<br>5. [\u53ef\u9009]\u5bf9\u7ec6\u80de\u8868\u9762\u6807\u5fd7\u7269\u8fdb\u884c\u67d3\u8272\uff1a\u4f7f\u7528Staining Buffer\u914d\u5236\u8868\u9762\u6297\u4f53\u9884\u6df7\u6db2\uff0c\u6bcf\u4e2a\u6837\u672c\u9700\u898150 \u03bcL\u7684\u6297\u4f53\u9884\u6df7\u6db2\uff0c\u4f7f\u67d3\u8272\u4f53\u7cfb\u603b\u4f53\u79ef\u7ea6\u4e3a100 \u03bcL\uff0c\u8f7b\u8f7b\u5730\u8109\u51b2\u6da1\u65cb\u6df7\u5408\uff0c4\u00b0C\u907f\u5149\u5b75\u80b230 min\u3002&nbsp;\u70b9\u51fb\u5b9e\u9a8c\u6b65\u9aa4\u6700\u540e\u7684\u5f80\u671f\u5185\u5bb9\uff1a\u7ec6\u80de\u8868\u9762\u6d41\u5f0f\u67d3\u8272\uff0c\u4e86\u89e3\u66f4\u591a\u3002<br>6. \u6700\u540e\u4e00\u6b21\u6d17\u6da4\u540e\uff0c\u5f03\u4e0a\u6e05\u5e76\u8109\u51b2\u6da1\u65cb\u6837\u54c1\u4ee5\u5b8c\u5168\u79bb\u89e3\u7ec6\u80de\u56e2\u5757\uff0c\u901a\u5e38\u4fdd\u7559\u7ea6100 \u03bcL\u6b8b\u4f59\u4f53\u79ef\u3002<br>7. \u6dfb\u52a0100&nbsp;\u03bcL IC\u56fa\u5b9a\u6db2\u6765\u56fa\u5b9a\u7ec6\u80de\uff0c\u4e4b\u540e\u8109\u51b2\u6da1\u65cb\u6df7\u5408\u3002<br>8. \u5ba4\u6e29\u6761\u4ef6\u4e0b\u907f\u5149\u5b75\u80b220-60\u5206\u949f\u3002<br>9. \u52a0\u51651 mL 1X\u7834\u819c\u6db2\uff0c\u5728\u5ba4\u6e29\u4e0b400-600 x g \u79bb\u5fc35\u5206\u949f\u3002<br>10. \u5f03\u4e0a\u6e05\uff0c\u91cd\u590d\u4e0a\u4e00\u6b65\u3002<br>11. \u5c06\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e100&nbsp;\u03bcL 1X\u7834\u819c\u6db2\u4e2d\uff0c\u76f4\u63a5\u52a0\u5165\u63a8\u8350\u91cf\u7684\u76f4\u6807\u4e00\u6297\u4ee5\u68c0\u6d4b\u7ec6\u80de\u5185\u6297\u539f\uff0c\u5e76\u5728\u5ba4\u6e29\u4e0b\u907f\u5149\u5b75\u80b220-60\u5206\u949f\u3002<br>12. \u52a0\u51651 mL 1X\u7834\u819c\u6db2\uff0c\u5ba4\u6e29\u4e0b400-600 x g\u79bb\u5fc35\u5206\u949f\u3002<br>13. \u5f03\u4e0a\u6e05\uff0c\u91cd\u590d\u4e0a\u4e00\u6b65\u3002<br>14. \u5c06\u67d3\u8272\u540e\u7684\u7ec6\u80de\u91cd\u60ac\u4e8e\u9002\u5f53\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u67d3\u8272\u6db2\u4e2d\uff0c\u4e0a\u673a\u68c0\u6d4b\u3002<br>15. \u7ed3\u679c\u5206\u6790\uff1a\u901a\u8fc7\u6d41\u5f0f\u7ec6\u80de\u672f\u5708\u95e8\u89c4\u5219\u5206\u6790\u86cb\u767d\u8868\u8fbe\u60c5\u51b5\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"554\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211623@2x-1024x554.png\" alt=\"\" class=\"wp-image-1093\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211623@2x-1024x554.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211623@2x-300x162.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211623@2x-768x416.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-211623@2x.png 1116w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u7ed3\u679c\u5206\u6790\u4e3e\u4f8b\uff1a\u901a\u8fc7\u6d41\u5f0f\u591a\u8272\u67d3\u8272\uff0c\u68c0\u6d4b\u7ecf\u523a\u6fc0\u540eT\u7ec6\u80de\u4e2dIFN-\u03b3\uff0cTNF-\u03b1\u548cIL-17A\u7b49\u7ec6\u80de\u56e0\u5b50\u7684\u8868\u8fbe\u60c5\u51b5\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-question-amp-answer\"><strong>Question &amp; Answer<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u7834\u819c\u5242\u6709\u6c89\u6dc0\u3001\u6709\u4e0d\u540c\u989c\u8272\uff0c\u662f\u6b63\u5e38\u73b0\u8c61\u5417\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u7834\u819c\u5242\u5185\u7684\u6c89\u6dc0\u901a\u5e38\u662f\u76d0\u6790\u51fa\uff0c\u4e0d\u5f71\u54cd\u4f7f\u7528\u3002\u7531\u4e8e\u989c\u8272\u4e0d\u5728\u4ea7\u54c1\u8d28\u68c0\u9879\u76ee\u5185\uff0c\u4e0d\u540c\u6279\u6b21\u53ef\u80fd\u4f1a\u51fa\u73b0\u989c\u8272\u5dee\u5f02\uff0c\u4f46\u4e0d\u5f71\u54cd\u4ea7\u54c1\u6027\u80fd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u7ec6\u80de\u6837\u672c\u7ecf\u8fc7\u8868\u9762\u67d3\u8272\u540e\u662f\u5426\u53ef\u4ee5\u4fdd\u5b58\u5728IC\u56fa\u5b9a\u6db2\u91cc\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u67d3\u8272\u5b8c\u6210\u540e\u6211\u4eec\u5efa\u8bae\u5c3d\u5feb\u4e0a\u673a\u68c0\u6d4b\uff0c\u5982\u679c\u5b9e\u5728\u6765\u4e0d\u53ca\u4e0a\u673a\uff0c\u53ef\u4ee5\u5c06100 \u03bcL \u6837\u54c1\u4e0e100 \u03bcL IC\u56fa\u5b9a\u6db2\uff08\u8d27\u53f700-8222-49\uff09\u6df7\u5408\uff0c\u4ece\u800c\u5c06\u6837\u54c1\u4fdd\u5b58\u5728IC\u56fa\u5b9a\u6db2\u4e2d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u80fd\u5426\u5148\u5bf9\u7ec6\u80de\u8fdb\u884c\u56fa\u5b9a\u7834\u819c\uff0c\u7136\u540e\u518d\u5bf9\u8868\u9762\u548c\u80de\u5185\u6807\u5fd7\u7269\u67d3\u8272\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u7406\u8bba\u4e0a\u6765\u8bf4\u53ef\u4ee5\uff0c\u4f46\u662f\u9700\u8981\u6ce8\u610f\u6297\u4f53\u7684\u514b\u9686\u53f7\u662f\u5426\u8010\u53d7\u56fa\u5b9a\/\u7834\u819c\u5904\u7406\uff0c\u8d5b\u9ed8\u98de\u63a2\u7d22\u4e86\u90e8\u5206\u6297\u4f53\u4e0d\u540c\u514b\u9686\u53f7\u7684\u517c\u5bb9\u6027\uff0c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/cell-analysis\/cell-analysis-learning-center\/cell-analysis-resource-library\/ebioscience-resources\/antibody-fixation-considerations.html?icid=cn-blog-bid\">\u70b9\u51fb\u4e86\u89e3\u66f4\u591a\u4fe1\u606f<\/a>\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u4e3a\u4ec0\u4e48\u56fa\u5b9a\u7834\u819c\u540e\uff0c\u8868\u9762\u6807\u5fd7\u7269\u7684\u8367\u5149\u4e22\u5931\u4e86\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5982\u679c\u6297\u4f53\u53d1\u751f\u5185\u5316\u7684\u8bdd\uff0c\u53ef\u80fd\u65e0\u6cd5\u68c0\u6d4b\u5230\u8868\u9762\u7684\u6807\u5fd7\u7269\uff1b\u6b64\u5916\u5982\u679c\u56fa\u5b9a\u7834\u819c\u8bd5\u5242\u4e2d\u5982\u679c\u542b\u9187\u7c7b\u8bd5\u5242<strong>\uff0888-8824-00\u5185\u7684\u56fa\u5b9a\u7834\u819c\u5242\u662f\u4e0d\u542b\u9187\u7c7b\u8bd5\u5242\u7684\uff09<\/strong>\uff0c\u4f1a\u6709\u5bfc\u81f4\u8367\u5149\u6dec\u706d\u7684\u53ef\u80fd\uff0c\u5c24\u5176\u5bf9\u4e8e\u8367\u5149\u86cb\u767d\u7c7b\u67d3\u6599\u5f71\u54cd\u6700\u5927\u3002\u56e0\u6b64\uff0c\u8981\u4f7f\u7528\u542b\u9187\u7c7b\u8bd5\u5242\u7684\u56fa\u5b9a\u7834\u819c\u5242\uff0c\u8868\u9762\u67d3\u8272\u5c3d\u91cf\u907f\u514d\u4f7f\u7528APC\u3001PE\u548cPerCP\u53ca\u5176\u590d\u5408\u67d3\u6599\u5076\u8054\u7684\u6297\u4f53\u3002\u7834\u819c\u64cd\u4f5c\u540e\uff0c\u53ef\u4ee5\u7ee7\u7eed\u4f7f\u7528\u542b\u6709\u8367\u5149\u86cb\u767d\u7c7b\u5076\u67d3\u6599\u8054\u7684\u6297\u4f53\u8fdb\u884c\u80de\u5185\u6807\u8bb0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*\u4ee5\u4e0a\u6570\u636e\u5747\u51fa\u81ea\u8d5b\u9ed8\u98de\u6d41\u5f0f\u7ec6\u80de\u672f\u7cbe\u54c1\u57f9\u8bad\u73ed\uff0c\u6240\u7528\u6d41\u5f0f\u7ec6\u80de\u4eea\u4e3aAttune\u2122 NxT\u6d41\u5f0f\u7ec6\u80de\u4eea\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u5bf9\u7ec6\u80de\u5185\u7684\u86cb\u767d\u9776\u6807\u67d3\u8272\uff0c\u5f80\u5f80\u9700\u8981\u7528\u5230\u56fa\u5b9a\u5242\u548c\u7834\u819c\u5242\uff0c\u5176\u76ee\u7684\u662f\u4e3a\u4e86\u56fa\u5b9a\u7ec6\u80de\u5e76\u7ed9\u7ec6\u80de\u819c\u7a7f\u5b54\uff0c\u4ee5\u4fbf\u8fdb\u884c\u540e<\/p>\n","protected":false},"author":1852,"featured_media":1120,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[106],"division":[9],"class_list":["post-1090","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-106","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-20T06:16:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:29+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1020\" \/>\n\t<meta property=\"og:image:height\" content=\"536\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01\",\"datePublished\":\"2026-03-20T06:16:43+00:00\",\"dateModified\":\"2026-04-22T21:59:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/\"},\"wordCount\":92,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/3.png\",\"keywords\":[\"\u56fa\u5b9a\u7834\u819c\u5242\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/\",\"name\":\"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/3.png\",\"datePublished\":\"2026-03-20T06:16:43+00:00\",\"dateModified\":\"2026-04-22T21:59:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/3.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/3.png\",\"width\":1020,\"height\":536},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ic-fixation-buffer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/","og_locale":"zh_CN","og_type":"article","og_title":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01","og_description":"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-20T06:16:43+00:00","article_modified_time":"2026-04-22T21:59:29+00:00","og_image":[{"width":1020,"height":536,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01","datePublished":"2026-03-20T06:16:43+00:00","dateModified":"2026-04-22T21:59:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/"},"wordCount":92,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png","keywords":["\u56fa\u5b9a\u7834\u819c\u5242"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/","name":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png","datePublished":"2026-03-20T06:16:43+00:00","dateModified":"2026-04-22T21:59:29+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u672c\u6587\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u6d41\u5f0f\u7ec6\u80de\u672f\u4e2d\u9488\u5bf9\u7ec6\u80de\u5185\u86cb\u767d\u9776\u6807\u67d3\u8272\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\uff0c\u6838\u5fc3\u56f4\u7ed5\u56fa\u5b9a\u5242\u4e0e\u7834\u819c\u5242\u7684\u4f5c\u7528\u3001\u8bd5\u5242\u914d\u5236\u3001\u6807\u51c6\u5316\u64cd\u4f5c\u6b65\u9aa4\u3001\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\u4ee5\u53ca\u76f8\u5173\u4ea7\u54c1\u63a8\u8350\u5c55\u5f00\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png","width":1020,"height":536},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ic-fixation-buffer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u7ec6\u80de\u5185\u6d41\u5f0f\u67d3\u8272\u505a\u5f97\u597d\uff0c\u56fa\u5b9a\u7834\u819c\u4e0d\u80fd\u5c11\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":106,"label":"\u56fa\u5b9a\u7834\u819c\u5242"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/3.png",760,399,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":106,"name":"\u56fa\u5b9a\u7834\u819c\u5242","slug":"%e5%9b%ba%e5%ae%9a%e7%a0%b4%e8%86%9c%e5%89%82","term_group":0,"term_taxonomy_id":106,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1090","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1090"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1090\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1120"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1090"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1090"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1090"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}