{"id":1096,"date":"2026-03-20T03:04:18","date_gmt":"2026-03-20T03:04:18","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1096"},"modified":"2026-04-22T21:59:29","modified_gmt":"2026-04-22T21:59:29","slug":"cytokine-experiment","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cytokine-experiment\/","title":{"rendered":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662f\u7ec6\u80de\u56e0\u5b50\"><strong>\u4ec0\u4e48\u662f\u7ec6\u80de\u56e0\u5b50\uff1f<\/strong><\/h2>\n\n\n\n<p>\u7ec6\u80de\u56e0\u5b50\u662f\u4e00\u7c7b\u5206\u6ccc\u6027\u86cb\u767d\u8d28\u6216\u591a\u80bd\uff0c\u5b83\u4eec\u5728\u7ec6\u80de\u95f4\u4f20\u9012\u4fe1\u53f7\u5e76\u8c03\u8282\u7ec6\u80de\u7684\u751f\u7406\u548c\u514d\u75ab\u529f\u80fd\u3002\u7ec6\u80de\u56e0\u5b50\u5728\u591a\u79cd\u751f\u7269\u8fc7\u7a0b\u4e2d\u53d1\u6325\u91cd\u8981\u4f5c\u7528\uff0c\u5305\u62ec\u7ec6\u80de\u589e\u6b96\u3001\u5206\u5316\u3001\u5b58\u6d3b\u3001\u708e\u75c7\u53cd\u5e94\u548c\u514d\u75ab\u5e94\u7b54\u7b49\u3002<\/p>\n\n\n\n<p>\u7ec6\u80de\u56e0\u5b50\u5728\u591a\u79cd\u75be\u75c5\u53d1\u751f\u548c\u53d1\u5c55\u4e2d\u53d1\u6325\u91cd\u8981\u4f5c\u7528\uff0c<strong>\u7ec6\u80de\u56e0\u5b50\u98ce\u66b4\uff08cytokine storm\uff0cCS\uff09<\/strong>\u662f\u4e00\u79cd\u5168\u8eab\u6027\u708e\u75c7\u53cd\u5e94\uff0c\u8fc7\u5ea6\u6fc0\u6d3b\u7684\u514d\u75ab\u7cfb\u7edf\u53ef\u80fd\u4f1a\u5bfc\u81f4\u708e\u75c7\u7ec6\u80de\u6b7b\u4ea1\uff0c\u4ece\u800c\u8fdb\u4e00\u6b65\u4fc3\u8fdb\u81f4\u75c5\u7684\u7ec6\u80de\u56e0\u5b50\u91ca\u653e\uff0c\u6700\u7ec8\u9020\u6210\u5168\u8eab\u708e\u75c7\u3002\u56e0\u6b64\uff0c\u7814\u7a76\u548c\u7406\u89e3\u7ec6\u80de\u56e0\u5b50\u7684\u529f\u80fd\u548c\u8c03\u63a7\u673a\u5236\u5bf9\u4e8e\u75be\u75c5\u7684\u8bca\u65ad\u548c\u6cbb\u7597\u5177\u6709\u91cd\u8981\u610f\u4e49\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"938\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212739@2x-1024x938.png\" alt=\"\" class=\"wp-image-1097\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212739@2x-1024x938.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212739@2x-300x275.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212739@2x-768x703.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212739@2x.png 1094w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56fe1.&nbsp;\u7ec6\u80de\u56e0\u5b50\u98ce\u66b4\u673a\u5236\u793a\u610f\u56fe<sup>[1]<\/sup><\/p>\n\n\n\n<p><sup>Karki R, Kanneganti TD. The &#8216;cytokine storm&#8217;: molecular mechanisms and therapeutic prospects. Trends Immunol. 2021 Aug;42(8):681-705. doi: 10.1016\/j.it.2021.06.001.&nbsp;<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5982\u4f55\u523a\u6fc0\u7ec6\u80de\u56e0\u5b50\u8868\u8fbe\"><strong>\u5982\u4f55\u523a\u6fc0\u7ec6\u80de\u56e0\u5b50\u8868\u8fbe\uff1f<\/strong><\/h2>\n\n\n\n<p>\u7ec6\u80de\u56e0\u5b50\u6d41\u5f0f\u67d3\u8272\u65f6\uff0c\u5f80\u5f80\u4f1a<strong>\u53d1\u73b0\u67d3\u8272\u7684\u4fe1\u53f7\u5f88\u5f31<\/strong>\uff0c\u5373\u4fbf\u6362\u6210\u8367\u5149\u5f3a\u5ea6\u9ad8\u7684\u8367\u5149\u57fa\u56e2\uff0c\u6548\u679c\u4e5f\u5e76\u6ca1\u6709\u592a\u591a\u6539\u5584\u3002\u8fd9\u901a\u5e38\u662f\u7531\u4e8e\u7ec6\u80de\u56e0\u5b50\u672c\u8eab\u8868\u8fbe\u4f4e\uff0c\u540c\u65f6\u4e5f\u53ef\u80fd\u4f1a\u56e0\u4e3a\u5176\u81ea\u8eab\u662f\u5206\u6ccc\u86cb\u767d\u7684\u7279\u70b9\u88ab\u8f6c\u8fd0\u5230\u80de\u5916\uff0c\u8fdb\u4e00\u6b65\u964d\u4f4e\u4e86\u7ec6\u80de\u5185\u7684\u8868\u8fbe\u6c34\u5e73\uff01\u8003\u8651\u5230\u8fd9\u4e00\u70b9\uff0c<strong>\u5bf9\u7ec6\u80de\u56e0\u5b50\u67d3\u8272\u524d\uff0c\u5f80\u5f80\u9700\u8981\u5bf9\u5176\u5148\u8fdb\u884c\u523a\u6fc0\u3002<\/strong><\/p>\n\n\n\n<p>\u5bf9\u4e8e\u7ec6\u80de\u56e0\u5b50\u7684\u523a\u6fc0\u6d3b\u5316\uff0c\u901a\u5e38\u662f\u4f7f\u7528\u7279\u5b9a\u80bd\u6216\u975e\u7279\u5f02\u6027\u6fc0\u6d3b\u6df7\u5408\u7269<strong>\u6fc0\u6d3b\u7ec6\u80de\uff0c\u5e76\u6dfb\u52a0\u86cb\u767d\u8d28\u8f6c\u8fd0\u6291\u5236\u5242\u4ee5\u5c06\u7ec6\u80de\u56e0\u5b50\u4fdd\u7559\u5728\u7ec6\u80de\u5185\u3002<\/strong>\u4f8b\u5982\u53ef\u4ee5\u4f7f\u7528\u4f5b\u6ce2\u9187\uff08PMA\uff09\u548c\u79bb\u5b50\u9709\u7d20\uff0c\u6765\u8bf1\u5bfc\u7ec6\u80de\u6d3b\u5316\uff0c\u4ea7\u751f\u7ec6\u80de\u56e0\u5b50\u3002\u540c\u65f6\uff0c\u8f85\u4ee5Brefeldin A \u548c\u83ab\u80fd\u83cc\u7d20\uff0c\u6765\u6291\u5236\u7ec6\u80de\u7684\u86cb\u767d\u8f6c\u8fd0\u529f\u80fd\uff0c\u4f7f\u523a\u6fc0\u4ea7\u751f\u7684\u7ec6\u80de\u56e0\u5b50\u5728\u7ec6\u80de\u5185\u84c4\u79ef\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"518\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212752@2x-1024x518.png\" alt=\"\" class=\"wp-image-1098\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212752@2x-1024x518.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212752@2x-300x152.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212752@2x-768x388.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212752@2x.png 1076w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe2.\u5c0f\u9f20\u813e\u810f\u7ec6\u80de\u672a\u53d7\u523a\u6fc0\uff08\u5de6\uff09\u6216\u7528\u7ec6\u80de\u523a\u6fc0\u6df7\u5408\u7269\uff08\u52a0\u86cb\u767d\u8d28\u8f6c\u8fd0\u6291\u5236\u5242\uff0c\u8d27\u53f7\uff1a00-4975-93\uff09\uff08\u53f3\uff09\u523a\u6fc0 5 \u5c0f\u65f6\uff0c\u6d41\u5f0f\u67d3\u8272\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50TNF\u03b1\u8868\u8fbe\u3002<\/p>\n\n\n\n<p>\u9488\u5bf9\u7ec6\u80de\u56e0\u5b50\u7684\u6d3b\u5316\u523a\u6fc0\u8bd5\u5242\uff0c\u6211\u4eec\u4e0d\u4ec5\u6709\u4e0a\u9762\u63d0\u53ca\u7684\u4f5b\u6ce2\u9187\uff08PMA\uff09\u548c\u79bb\u5b50\u9709\u7d20\u4e0eBrefeldin A \u548c\u83ab\u80fd\u83cc\u7d20\u7684\u6df7\u5408\u7269\uff0c\u4e5f\u6709\u591a\u79cd\u5355\u72ec\u7ec4\u5206\u53ca\u5176\u4ed6\u523a\u6fc0\u5242\u53ef\u4ee5\u63d0\u4f9b\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5982\u4f55\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\"><strong>\u5982\u4f55\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\uff1f<\/strong><\/h2>\n\n\n\n<p>\u524d\u9762\u63d0\u5230\u4e86\uff0c\u5982\u4f55\u8bf1\u5bfc\u523a\u6fc0\u66f4\u591a\u7684\u7ec6\u80de\u56e0\u5b50\u8868\u8fbe\u5e76\u4f7f\u7528\u86cb\u767d\u8f6c\u8fd0\u6291\u5236\u5242\u6291\u5236\u7ec6\u80de\u56e0\u5b50\u8f6c\u8fd0\u5230\u80de\u5916\u3002\u800c\u7ec6\u80de\u56e0\u5b50\u6d41\u5f0f\u67d3\u8272\uff0c\u8fd8\u9700\u8981\u5bf9\u7ec6\u80de\u8fdb\u884c<strong>\u56fa\u5b9a\u548c\u7834\u819c\u5904\u7406\u540e\u518d\u67d3\u8272<\/strong>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"112\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212809@2x-1024x112.png\" alt=\"\" class=\"wp-image-1104\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212809@2x-1024x112.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212809@2x-300x33.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212809@2x-768x84.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212809@2x.png 1098w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e00\u6b65-\u6837\u54c1\u5236\u5907\"><strong>\u7b2c\u4e00\u6b65 \u6837\u54c1\u5236\u5907<\/strong><\/h3>\n\n\n\n<p>\u5728\u7ec6\u80de\u56e0\u5b50\u6d41\u5f0f\u67d3\u8272\u8fc7\u7a0b\u4e2d\uff0c\u9700\u8981\u5bf9\u5236\u5907\u597d\u7684\u5355\u7ec6\u80de\u60ac\u6db2\u5148\u8fdb\u884c\u523a\u6fc0\u6d3b\u5316\u7ec6\u80de\u56e0\u5b50\u8868\u8fbe\uff0c\u624d\u80fd\u8fdb\u4e00\u6b65\u67d3\u8272\u3002\u5728\u5b9e\u9a8c\u6b65\u9aa4\u7ed3\u675f\u5904\uff0c\u70b9\u51fb\u5f80\u671fDr.\u8d5b\u6d41\u5f0f\u5c0f\u8bfe\u5802-\u6d41\u5f0f\u6837\u672c\u5236\u5907\u65b9\u6cd5\uff0c\u4e86\u89e3\u66f4\u591a\u5185\u5bb9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e8c\u6b65-\u6b7b\u6d3b\u67d3\u8272-\u53ef\u9009\"><strong>\u7b2c\u4e8c\u6b65 \u6b7b\u6d3b\u67d3\u8272\uff08\u53ef\u9009\uff09<\/strong><\/h3>\n\n\n\n<p>\u7531\u4e8e\u7ec6\u80de\u56e0\u5b50\u7684\u67d3\u8272\u9700\u8981\u5bf9\u7ec6\u80de\u8fdb\u884c\u56fa\u5b9a\u7834\u819c\u5904\u7406\uff0c\u56e0\u6b64\uff0c\u6211\u4eec\u53ea\u80fd\u9009\u62e9\u80fa\u53cd\u5e94\u6027\u7684\u6b7b\u6d3b\u67d3\u6599\uff0c\u6765\u517c\u5bb9\u540e\u7eed\u7ec6\u80de\u56fa\u5b9a\u7834\u819c\u7684\u64cd\u4f5c\u3002\u4e0d\u540c\u4e8e\u6838\u9178\u7c7b\u7684\u6b7b\u6d3b\u67d3\u6599\uff0c\u80fa\u53cd\u5e94\u6027\u7684\u6b7b\u6d3b\u67d3\u6599\u4e3b\u8981\u662f\u4e0e\u7ec6\u80de\u7684\u86cb\u767d\u4f2f\u80fa\u57fa\u56e2\u8fdb\u884c\u6807\u8bb0\u3002\u9700\u8981\u6ce8\u610f\u7684\u662f\uff0c<strong>\u8fd9\u7c7b\u80fa\u53cd\u5e94\u6027\u7684\u6b7b\u6d3b\u67d3\u6599\uff0c\u53ea\u517c\u5bb9\u919b\u7c7b\u8bd5\u5242\u7684\u56fa\u5b9a\u5904\u7406\u3002<\/strong>\u5728\u5b9e\u9a8c\u6b65\u9aa4\u7ed3\u675f\u5904\uff0c\u70b9\u51fb\u5f80\u671fDr.\u8d5b\u6d41\u5f0f\u5c0f\u8bfe\u5802-\u6d41\u5f0f\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\uff0c\u4e86\u89e3\u66f4\u591a\u5185\u5bb9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e09\u6b65-fc\u53d7\u4f53\u5c01\u95ed-\u53ef\u9009\"><strong>\u7b2c\u4e09\u6b65 Fc\u53d7\u4f53\u5c01\u95ed\uff08\u53ef\u9009\uff09<\/strong><\/h3>\n\n\n\n<p>\u5de8\u566c\u7ec6\u80de\u3001\u9ad3\u7cfb\u7ec6\u80de\u7b49\u7ec6\u80de\u8868\u9762\u4f1a\u6709Fc\u53d7\u4f53\uff0c\u82e5\u662f\u4e0d\u7ecf\u5c01\u95ed\uff0c\u5219\u53ef\u80fd\u4f1a\u5bfc\u81f4\u7ec6\u80de\u51fa\u73b0\u9ad8\u80cc\u666f\u53ca\u5047\u9633\u6027\u7b49\u95ee\u9898\uff0cFc\u53d7\u4f53\u5c01\u95ed\u53ef\u51cf\u5c11\u6297\u4f53\u7684\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3002\u5728\u5b9e\u9a8c\u6b65\u9aa4\u7ed3\u675f\u5904\uff0c\u70b9\u51fb\u5f80\u671fDr.\u8d5b\u6d41\u5f0f\u5c0f\u8bfe\u5802-\u5c01\u95edFc\u53d7\u4f53\u6d41\u5f0f\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\uff0c\u4e86\u89e3\u66f4\u591a\u5185\u5bb9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7b2c\u56db\u6b65-\u56fa\u5b9a\u7834\u819c\"><strong>\u7b2c\u56db\u6b65 \u56fa\u5b9a\u7834\u819c<\/strong><\/h3>\n\n\n\n<p>\u5bf9\u4e8e\u7ec6\u80de\u56e0\u5b50\u67d3\u8272\uff0c\u5728\u4f7f\u7528\u86cb\u767d\u8f6c\u8fd0\u6291\u5236\u5242\u540e\uff0c\u7ec6\u80de\u56e0\u5b50\u5728\u7ec6\u80de\u8d28\u5185\u51fa\u73b0\u79ef\u7d2f\u3002\u6b63\u5e38\u60c5\u51b5\u4e0b\uff0c\u8367\u5149\u6807\u8bb0\u7684\u6297\u4f53\u65e0\u6cd5\u901a\u8fc7\u5b8c\u6574\u7684\u7ec6\u80de\u819c\u8fdb\u5165\u7ec6\u80de\u5185\uff0c\u7528\u6d41\u5f0f\u7ec6\u80de\u4eea\u6d4b\u5b9a\u7ec6\u80de\u5185\u6297\u539f\uff0c\u9700\u5148\u5229\u7528\u7834\u819c\u5242\u7834\u574f\u7ec6\u80de\u819c\u7684\u5b8c\u6574\u6027\uff0c\u4ea7\u751f\u53ef\u4f9b\u6297\u4f53\u901a\u8fc7\u7684\u5c0f\u5b54\u3002\u7834\u819c\u6548\u679c\u7684\u597d\u574f\u5c06\u76f4\u63a5\u5f71\u54cd\u8367\u5149\u67d3\u8272\u548c\u7ed3\u679c\u5206\u6790\u3002\u5e02\u9762\u4e0a\u4e5f\u6709\u5546\u54c1\u5316\u7684\u6d41\u5f0f\u56fa\u5b9a\u7834\u819c\u7f13\u51b2\u6db2\u53ef\u4ee5\u63d0\u4f9b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e94\u6b65-\u6297\u4f53\u67d3\u8272\"><strong>\u7b2c\u4e94\u6b65 \u6297\u4f53\u67d3\u8272<\/strong><\/h3>\n\n\n\n<p>\u5728\u5bf9\u7ec6\u80de\u8fdb\u884c\u56fa\u5b9a\u7834\u819c\u5904\u7406\u540e\uff0c\u5373\u53ef\u5bf9\u7ec6\u80de\u56e0\u5b50\u8fdb\u884c\u67d3\u8272\u3002\u901a\u5e38\u6765\u8bf4\u5546\u54c1\u5316\u7684\u6d41\u5f0f\u6297\u4f53\u4f1a\u63d0\u4f9b\u5efa\u8bae\u7528\u91cf\uff0c\u53ef\u5148\u6839\u636e\u5efa\u8bae\u7528\u91cf\u8fdb\u884c\u5c1d\u8bd5\u3002\u901a\u5e38\u4f7f\u7528\u5ba4\u6e29\u907f\u5149\u5b75\u80b230-60 min\u7684\u6761\u4ef6\u3002\u53ef\u4ee5\u6839\u636e\u67d3\u8272\u6548\u679c\u4f18\u5316\u5b75\u80b2\u6e29\u5ea6\u548c\u65f6\u95f4\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-question-amp-answer\"><strong>Question &amp; Answer<\/strong><\/h2>\n\n\n\n<p><strong>Q \u7ec6\u80de\u56e0\u5b50\u67d3\u8272\u65f6\uff0c\u6d89\u53ca\u5176\u4ed6\u7684\u8868\u9762\u6297\u4f53\u67d3\u8272\uff0c\u53ef\u4ee5\u4e00\u8d77\u505a\u5417\uff1f<\/strong><\/p>\n\n\n\n<p><strong>A<\/strong> \u53ef\u4ee5\uff0c\u4f46\u662f\u901a\u5e38\u9700\u8981\u5148\u5bf9\u8868\u9762\u6297\u4f53\u67d3\u8272\u540e\uff0c\u7ec6\u80de\u56fa\u5b9a\u7834\u819c\u5904\u7406\uff0c\u518d\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u3002\u540c\u65f6\u8981\u505a\u6d41\u5f0f\u8868\u9762\u67d3\u8272\u548c\u7ec6\u80de\u56e0\u5b50\u67d3\u8272\uff0c\u901a\u5e38\u5927\u90e8\u5206\u60c5\u51b5\u4e0b\uff0c\u53ef\u4ee5\u53c2\u8003\u4ee5\u4e0b\u6d41\u7a0b\u56fe\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"908\" height=\"92\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212820@2x.png\" alt=\"\" class=\"wp-image-1106\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212820@2x.png 908w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212820@2x-300x30.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260318-212820@2x-768x78.png 768w\" sizes=\"auto, (max-width: 908px) 100vw, 908px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4ec0\u4e48\u662f\u7ec6\u80de\u56e0\u5b50\uff1f \u7ec6\u80de\u56e0\u5b50\u662f\u4e00\u7c7b\u5206\u6ccc\u6027\u86cb\u767d\u8d28\u6216\u591a\u80bd\uff0c\u5b83\u4eec\u5728\u7ec6\u80de\u95f4\u4f20\u9012\u4fe1\u53f7\u5e76\u8c03\u8282\u7ec6\u80de\u7684\u751f\u7406\u548c\u514d\u75ab\u529f\u80fd\u3002\u7ec6\u80de\u56e0\u5b50\u5728<\/p>\n","protected":false},"author":1852,"featured_media":1118,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[90,104],"division":[9],"class_list":{"0":"post-1096","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-90","9":"tag-104","10":"division-bid","11":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-20T03:04:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:29+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1094\" \/>\n\t<meta property=\"og:image:height\" content=\"1002\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c\",\"datePublished\":\"2026-03-20T03:04:18+00:00\",\"dateModified\":\"2026-04-22T21:59:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/\"},\"wordCount\":50,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2.png\",\"keywords\":[\"\u6d41\u5f0f\",\"\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/\",\"name\":\"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2.png\",\"datePublished\":\"2026-03-20T03:04:18+00:00\",\"dateModified\":\"2026-04-22T21:59:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/2.png\",\"width\":1094,\"height\":1002},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cytokine-experiment\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/","og_locale":"zh_CN","og_type":"article","og_title":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c","og_description":"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-20T03:04:18+00:00","article_modified_time":"2026-04-22T21:59:29+00:00","og_image":[{"width":1094,"height":1002,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cytokine-experiment\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c","datePublished":"2026-03-20T03:04:18+00:00","dateModified":"2026-04-22T21:59:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cytokine-experiment\/"},"wordCount":50,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png","keywords":["\u6d41\u5f0f","\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cytokine-experiment\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/","name":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png","datePublished":"2026-03-20T03:04:18+00:00","dateModified":"2026-04-22T21:59:29+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u672c\u6587\u56f4\u7ed5\u7ec6\u80de\u56e0\u5b50\u7684\u5b9a\u4e49\u3001\u529f\u80fd\u3001\u76f8\u5173\u75c5\u7406\u73b0\u8c61\u4ee5\u53ca\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u56e0\u5b50\u7684\u5b8c\u6574\u5b9e\u9a8c\u6d41\u7a0b\u5c55\u5f00\u7cfb\u7edf\u4ecb\u7ecd\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2.png","width":1094,"height":1002},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cytokine-experiment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u8f7b\u677e\u4e0a\u624b\u6d41\u5f0f\u67d3\u8272\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":90,"label":"\u6d41\u5f0f"},{"value":104,"label":"\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/2-1024x938.png",760,696,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":90,"name":"\u6d41\u5f0f","slug":"%e6%b5%81%e5%bc%8f","term_group":0,"term_taxonomy_id":90,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":104,"name":"\u7ec6\u80de\u56e0\u5b50\u5b9e\u9a8c","slug":"%e7%bb%86%e8%83%9e%e5%9b%a0%e5%ad%90%e5%ae%9e%e9%aa%8c","term_group":0,"term_taxonomy_id":104,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1096"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1096\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1118"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1096"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1096"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1096"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}