{"id":1151,"date":"2026-03-24T09:09:04","date_gmt":"2026-03-24T09:09:04","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1151"},"modified":"2026-04-22T21:59:28","modified_gmt":"2026-04-22T21:59:28","slug":"mouse-bone-marrow-cell-isolation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/","title":{"rendered":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u9aa8\u9ad3<\/strong>\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de[1]\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90[2]\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002\u90a3\u4e48\u63a5\u4e0b\u6765\u6211\u4eec\u548cDr \u8d5b\u4e00\u8d77\u770b\u770b\u600e\u4e48\u5f97\u5230\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5427\uff01<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9e\u9a8c\u6750\u6599\"><strong>\u5b9e\u9a8c\u6750\u6599<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7ec6\u80de\u57f9\u517b\u76bf<\/li>\n\n\n\n<li>75% \u9152\u7cbe<\/li>\n\n\n\n<li>RPMI 1640\u5b8c\u5168\u57f9\u517b\u57fa\uff08\u80ce\u725b\u8840\u6e05\uff1a\u7ec8\u6d53\u5ea6 10%\uff1bL-Glutamine\uff1a\u7ec8\u6d53\u5ea62 mM\uff1b\u53ef\u9009\uff1a1% v\/v\u9752\u9709\u7d20-\u94fe\u9709\u7d20\u3002\uff09<\/li>\n\n\n\n<li>\u706d\u83cc\u7684\u773c\u79d1\u526a\u548c\u954a\u5b50\uff08\u6216\u5200\u7247\uff09<\/li>\n\n\n\n<li>1-3 mL \u6ce8\u5c04\u5668\uff08\u65e0\u83cc\uff09<\/li>\n\n\n\n<li>25 \u53f7\u9488\u5934\uff08\u65e0\u83cc\uff09<\/li>\n\n\n\n<li>\u65e0\u83cc70 \u03bcm \u7ec6\u80de\u7b5b\u7f51<\/li>\n\n\n\n<li>\u65e0\u83cc50 mL \u79bb\u5fc3\u7ba1<\/li>\n\n\n\n<li>\u7ea2\u7ec6\u80de\uff08RBC\uff09\u88c2\u89e3\u7f13\u51b2\u6db2\uff1a\u5982\u679c\u975e\u65e0\u83cc\uff0c\u5efa\u8bae\u901a\u8fc70.22um\u6ee4\u819c\u9664\u83cc<\/li>\n\n\n\n<li>Invitrogen Countess 3 FL \u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea<\/li>\n\n\n\n<li>\u78f7\u9178\u76d0\u7f13\u51b2\u6db2\uff08PBS\uff09<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9e\u9a8c\u6b65\u9aa4\"><strong>\u5b9e\u9a8c\u6b65\u9aa4<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-part-\u2170-\u83b7\u53d6\u80a1\u9aa8\"><strong>Part \u2160 \u83b7\u53d6\u80a1\u9aa8<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp;\u5904\u6b7b\u5c0f\u9f20\u540e\uff0c\u752875%\u9152\u7cbe\u5145\u5206\u6d88\u6bd2\uff0c\u5728<strong>\u65e0\u83cc\u6761\u4ef6\u4e0b<\/strong>\u5206\u79bb\u5c0f\u9f20\u80a1\u9aa8\uff0c\u80a1\u9aa8\u662f\u4f4d\u4e8e\u819d\u5173\u8282\u4e0e\u9aa8\u76c6\u80ef\u5173\u8282\u4e4b\u95f4\u7684\u957f\u9aa8 \uff08\u8bf7\u53c2\u8003\u56fe\u4e00\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u5728\u5265\u79bb\u65f6\uff0c\u8bf7\u5728\u9aa8\u76c6\u8de8\u5173\u8282\u4e0a\u65b9\u526a\u4e0b\u5927\u817f\uff0c\u5e76\u5728\u5728\u819d\u5173\u8282\u4e0b\u65b9\u53ef\u6d3b\u52a8\u5904\u526a\u4e0b\u80a1\u9aa8\u4e0b\u7aef\u3002\u6ce8\u610f\u5265\u79bb\u8fc7\u7a0b\u4e2d\u4e0d\u8981\u7834\u574f\u80a1\u9aa8\u4e24\u7aef\u5173\u8282\uff08\u8bf7\u53c2\u8003\u56fe\u4e8c\u81f3\u56fe\u4e09\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3. \u4f7f\u7528\u65e0\u83cc\u7684\u526a\u5200\uff0c\u954a\u5b50\u526a\u6389\u9aa8\u5934\u4e0a\u7684\u808c\u8089\u548c\u7ea4\u7ef4\u7ec4\u7ec7\uff0c\u6574\u4e2a\u64cd\u4f5c\u8fc7\u7a0b\u7559\u610f\u4e0d\u8981\u7834\u574f\u5173\u8282\u6216\u8005\u9aa8\u5934\u3002\u53ef\u7528\u526a\u5200\u522e\u9664\u9aa8\u5934\u8868\u9762\u7684\u808c\u8089\u83b7\u5f97\u5982\u56fe\u56db\u6240\u793a\u7684\u80a1\u9aa8\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. \u4e3a\u83b7\u5f97\u66f4\u591a\u9aa8\u9ad3\u7ec6\u80de\uff0c\u53ef\u7528\u4e0a\u8ff0\u76f8\u4f3c\u7684\u65b9\u6cd5\u83b7\u53d6\u80eb\u9aa8\u5185\u9aa8\u9ad3\u7ec6\u80de\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"616\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214526@2x-1024x616.png\" alt=\"\" class=\"wp-image-1153\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214526@2x-1024x616.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214526@2x-300x180.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214526@2x-768x462.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214526@2x.png 1360w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e00\uff1a\u5c0f\u9f20\u817f\u9aa8\u7b80\u6613\u89e3\u5256\u56fe<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"612\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214551@2x-1024x612.png\" alt=\"\" class=\"wp-image-1154\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214551@2x-1024x612.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214551@2x-300x179.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214551@2x-768x459.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214551@2x.png 1366w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e8c\uff1a\u5728\u9aa8\u76c6\u8de8\u5173\u8282\u4e0a\u65b9\u526a\u65ad\u5927\u817f<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214606@2x-1024x608.png\" alt=\"\" class=\"wp-image-1155\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214606@2x-1024x608.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214606@2x-300x178.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214606@2x-768x456.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214606@2x.png 1372w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e09\uff1a\u5728\u819d\u5173\u8282\u4e0b\u65b9\u526a\u65ad\u808c\u8089\/\u7b4b\u819c<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"606\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214622@2x-1024x606.png\" alt=\"\" class=\"wp-image-1156\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214622@2x-1024x606.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214622@2x-300x178.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214622@2x-768x455.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214622@2x.png 1378w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u56db\uff1a\u808c\u8089\u5265\u79bb\u5e72\u51c0\u7684\u80a1\u9aa8<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-part-ii-nbsp-\u6536\u96c6\u9aa8\u9ad3\u7ec6\u80de\"><strong>Part II&nbsp;\u6536\u96c6\u9aa8\u9ad3\u7ec6\u80de<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">5. \u53ef\u5c06\u5b8c\u6574\u7684\u9aa8\u5934\u7f6e\u4e8e\u57f9\u517b\u76bf\u4e2d\uff0c\u4f7f\u752875%\u9152\u7cbe\u6e05\u6d171-2min\uff0c\u518d\u653e\u5165\u542b\u6709\u65e0\u83ccPBS\u7684\u57f9\u517b\u76bf\u4e2d\u6d17\u6389\u9152\u7cbe\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. \u5c06 70 \u00b5m \u7ec6\u80de\u7b5b\u7f51\u7f6e\u4e8e 50 mL \u79bb\u5fc3\u7ba1\u9876\u90e8\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7. \u7528\u65e0\u83cc\u7684\u773c\u79d1\u526a\u526a\u65ad\u80a1\u9aa8\u7684\u4e24\u7aef\u5173\u8282\uff0c\u66b4\u9732\u51fa\u9aa8\u9ad3\u8154\uff08\u8bf7\u53c2\u8003\u56fe\u4e94\uff09\uff0c\u5c06 25 \u53f7\u9488\u5934\u88c5\u5728\u6ce8\u5c04\u5668\u4e0a\u3002\u7528\u6ce8\u5c04\u5668\u62bd\u54385 mL\u5de6\u53f3\u5b8c\u5168\u57f9\u517b\u57fa\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8. \u7528\u954a\u5b50\u5c06\u9aa8\u5934\u76f4\u7acb\u4e8e\u7b5b\u7f51\u4e0a\u65b9\uff0c\u518d\u7528\u6ce8\u5c04\u5668\u5c0f\u5fc3\u5c06\u9aa8\u9ad3\u51b2\u51fa\u6765\uff08\u8bf7\u53c2\u8003\u56fe\u516d\uff09\u3002\u5fc5\u8981\u65f6\uff0c<strong>\u91cd\u590d\u51b2\u6d17<\/strong>\uff0c\u5f53\u9aa8\u5934<strong>\u5448\u767d\u8272<\/strong>\u5219\u8868\u660e\u5df2\u51b2\u51fa\u6240\u6709\u9aa8\u9ad3\uff08\u8bf7\u53c2\u8003\u56fe\u4e03\uff09\u3002\u5bf9\u6240\u6709\u9aa8\u5934\u91cd\u590d\u8be5\u6b65\u9aa4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9. \u5982\u679c\u526a\u6389\u7684\u80a1\u9aa8\u5173\u8282\u8f83\u5927\uff0c\u53ef\u8fdb\u4e00\u6b65\u7528\u526a\u5200<strong>\u5c06\u5176\u526a\u788e<\/strong>\uff0c\u5e76\u75281mL\u79fb\u6db2\u5668\u51b2\u6d17\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10. \u4f7f\u7528\u6ce8\u5c04\u5668\u7684\u67f1\u585e\uff08\u8bf7\u52ff\u89e6\u6478\u67f1\u585e\u7684\u9ed1\u8272\u6a61\u80f6\uff1b\u4fdd\u6301\u65e0\u83cc\uff09\uff0c\u5411\u4e0b\u7528\u529b\u987a\/\u9006\u65f6\u9488\u6363\u788e\u7ec6\u80de\u7b5b\u7f51\u4e2d\u7684\u9aa8\u9ad3\uff08\u8bf7\u53c2\u8003\u56fe\u516b\uff09\u3002\u786e\u8ba4\u9aa8\u9ad3<strong>\u5747\u88ab\u6363\u788e<\/strong>\uff0c\u6ca1\u6709\u5757\u72b6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11. \u7528 RPMI \u5b8c\u5168\u57f9\u517b\u57fa\u5c06\u67f1\u585e\u7aef\u5269\u4e0b\u7684\u9aa8\u9ad3\u51b2\u5230\u7b5b\u7f51\u4e2d\uff0c\u5c3d\u53ef\u80fd\u591a\u5730\u6536\u96c6\u9aa8\u9ad3\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12. \u7528\u5b8c\u5168\u57f9\u517b\u57fa\u51b2\u6d17\u7b5b\u7f51\u3002\u53d6\u4e0b\u7b5b\u7f51\uff0c\u76d6\u4e0a\u76d6\u5b50\u3002\u5728 4\u00b0C \u4e0b 600 x g \u79bb\u5fc3\u7ec6\u80de 4 \u5206\u949f\u3002\u4e22\u5f03\u4e0a\u6e05\u6db2\uff08\u8bf7\u53c2\u8003\u56fe\u4e5d\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214908@2x-1024x610.png\" alt=\"\" class=\"wp-image-1157\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214908@2x-1024x610.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214908@2x-300x179.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214908@2x-768x458.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214908@2x.png 1356w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e94\uff1a\u526a\u6389\u80a1\u9aa8\u4e24\u7aef\u5173\u8282<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"615\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214919@2x-1024x615.png\" alt=\"\" class=\"wp-image-1158\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214919@2x-1024x615.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214919@2x-300x180.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214919@2x-768x461.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214919@2x.png 1358w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u516d\uff1a\u7528\u57f9\u517b\u57fa\u51b2\u4e2d\u6d17\u9aa8\u9ad3<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"605\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214930@2x-1024x605.png\" alt=\"\" class=\"wp-image-1159\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214930@2x-1024x605.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214930@2x-300x177.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214930@2x-768x454.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214930@2x.png 1380w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e03\uff1a\u51b2\u6d17\u5e72\u51c0\u540e\u82cd\u767d\u7684\u80a1\u9aa8<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"596\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214942@2x-1024x596.png\" alt=\"\" class=\"wp-image-1160\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214942@2x-1024x596.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214942@2x-300x175.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214942@2x-768x447.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214942@2x.png 1384w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u516b\uff1a\u8fdb\u4e00\u6b65\u7814\u78e8\u6363\u788e\u9aa8\u9ad3<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"607\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x-1024x607.png\" alt=\"\" class=\"wp-image-1161\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x-1024x607.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x-300x178.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x-768x455.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png 1360w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe\u4e5d\uff1a\u79bb\u5fc3\u540e\u83b7\u5f97\u7684\u9aa8\u9ad3\u7ec6\u80de<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">13. \u52a0\u5165 5 mL \u5de6\u53f3\u7684\u5b8c\u5168\u57f9\u517b\u57fa\u91cd\u60ac\u7ec6\u80de\uff0c\u4e0a\u4e0b\u5439\u6253\u3002\u53ef\u91cd\u65b0\u8fc7\u7b5b\uff0c\u83b7\u53d6\u5355\u7ec6\u80de\u60ac\u6db2\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Dr.\u8d5b\u53cb\u60c5\u63d0\u793a\uff1a<\/strong><\/em>\u8fd9\u4e00\u6b65\u7ea2\u7ec6\u80de\u8fd8\u672a\u88c2\u89e3\uff0c\u5982\u679c\u9700\u8981\u8ba1\u6570\u5efa\u8bae\u4f7f\u7528AO\/PI \u8367\u5149\u6cd5\u8ba1\u6570\u6709\u6838\u7ec6\u80de\u54e6\u3002\u63a8\u8350\u5927\u5bb6\u4f7f\u7528\u8d5b\u9ed8\u98de\u7684ReadyCount\u2122 Green\/Red Viability Stain \uff08cat# A49905\uff09\u642d\u914dCountess 3FL\uff0c\u6b64\u8bd5\u5242\u4e2dAO\u548cPI\u4e24\u79cd\u8367\u5149\u67d3\u6599\u7684\u6bd4\u4f8b\u7ecf\u8fc7\u4f18\u5316\uff0c\u53ef\u4ee5\u5feb\u6377\u51c6\u786e\u5730\u53cd\u6620\u6b7b\u6d3b\u7ec6\u80de\u7684\u6570\u91cf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">14. \u7528\u9002\u5f53\u7684\u57f9\u517b\u57fa\u5c06\u7ec6\u80de\u91cd\u60ac\uff0c\u4f7f\u8fbe\u5230\u6240\u9700\u7684\u7ec6\u80de\u6d53\u5ea6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">15. \u6839\u636e\u4e0b\u6e38\u7684\u5e94\u7528\u51b3\u5b9a\u662f\u5426\u9700\u8981\u88c2\u89e3\u7ea2\u7ec6\u80de\u6216\u8005\u76f4\u63a5\u8fdb\u884c\u57f9\u517b\u3001\u5206\u6790\u7b49\uff08\u7ea2\u7ec6\u80de\u88c2\u89e3\u540e\u4e5f\u53ef\u4ee5\u5229\u7528\u53f0\u76fc\u84dd\u6216AO\/PI\u67d3\u8272\u540e\u8fdb\u884c\u8ba1\u6570\u54e6\uff09\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-question-amp-answer\"><strong>Question &amp; Answer<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u4e3a\u4ec0\u4e48\u6211\u5206\u79bb\u5f97\u5230\u7684\u9aa8\u9ad3\u7ec6\u80de\u5f88\u5c11\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5728\u5265\u79bb\u9aa8\u5934\u548c\u808c\u8089\u65f6\uff0c\u80a1\u9aa8\u7684\u4e24\u7aef\u5173\u8282\u4e00\u5b9a\u8981\u5b8c\u6574\u4fdd\u7559\uff0c\u82e5\u662f\u526a\u7834\uff0c\u53ef\u80fd\u4f1a\u5bfc\u81f4\u7ec6\u80de\u635f\u5931\uff1b\u5176\u6b21\uff0c\u526a\u4e0b\u7684\u5173\u8282\u53ef\u8fdb\u4e00\u6b65\u526a\u788e\uff0c\u80a1\u9aa8\u4e00\u5b9a\u8981\u5145\u5206\u51b2\u6d17\u76f4\u81f3\u82cd\u767d\uff1b\u6700\u540e\u6536\u96c6\u7684\u9aa8\u9ad3\u5728\u8fc7\u7b5b\u65f6\u53ef\u4ee5\u518d\u8fdb\u884c\u7814\u78e8\u3002\u5f53\u7136\uff0c\u5982\u679c\u9700\u8981\u5c3d\u91cf\u591a\u7684\u9aa8\u9ad3\u7ec6\u80de\uff0c\u4e5f\u53ef\u4ee5\u518d\u5206\u79bb\u80eb\u9aa8\u548c\u80b1\u9aa8\u5185\u7684\u9aa8\u9ad3\u7ec6\u80de\uff0c\u5176\u6b65\u9aa4\u4e0e\u4e0a\u8ff0\u76f8\u4f3c\u54e6\u3002\u6b64\u5916\uff0c\u4e5f\u8981\u4f7f\u7528\u5065\u5eb7\u7684\u5c0f\u9f20\u8fdb\u884c\u5b9e\u9a8c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u4e3a\u4ec0\u4e48\u6211\u83b7\u53d6\u7684\u9aa8\u9ad3\u7ec6\u80de\u4f1a\u51fa\u73b0\u5fae\u751f\u7269\u6c61\u67d3\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5c0f\u9f20\u5904\u6b7b\u540e\uff0c\u8bf7\u5145\u5206\u4e3a\u5c0f\u9f20\u76ae\u6bdb\u548c\u8eab\u4f53\u706d\u83cc\u3002\u83b7\u5f97\u5b8c\u6574\u7684\u80a1\u9aa8\u540e\uff0c\u4e5f\u53ef\u4ee5\u4f7f\u5176\u6d78\u6ce1\u4e0e\u9152\u7cbe\u4e2d\u8fdb\u4e00\u6b65\u6d88\u6bd2\uff0c\u5b9e\u9a8c\u7528\u5230\u7684\u773c\u79d1\u526a\u548c\u954a\u5b50\u5747\u9700\u8981\u706d\u83cc\u3002\u82e5\u8fd8\u662f\u4e0d\u653e\u5fc3\uff0c\u53ef\u4ee5\u5728\u57f9\u517b\u57fa\u4e2d\u6dfb\u52a0\u4e00\u5b9a\u7684\u6297\u751f\u7d20\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u6211\u83b7\u5f97\u7684\u9aa8\u9ad3\u7ec6\u80de\u662f\u5426\u5fc5\u987b\u88c2\u89e3\u7ea2\u7ec6\u80de\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u8fd9\u4e2a\u95ee\u9898\u9700\u8981\u6839\u636e\u81ea\u5df1\u7684\u4e0b\u6e38\u5b9e\u9a8c\u6765\u53c2\u8003\u6587\u732e\uff1b\u4f8b\u5982\u5982\u679c\u9700\u8981\u57f9\u517b\u83b7\u53d6MSC, \u53ef\u4ee5\u4e0d\u88c2\u89e3\u76f4\u63a5\u57f9\u517b\uff1b\u5982\u679c\u9700\u8981\u5229\u7528\u9aa8\u9ad3\u4e2d\u5355\u6838\u7ec6\u80de\u5206\u5316\u6210\u4e3a\u5de8\u566c\u6216\u8005\u6811\u7a81\u72b6\u7ec6\u80de\uff0c\u4e00\u822c\u9700\u8981\u88c2\u7ea2\uff08\u53ef\u4ee5\u4f7f\u7528\u8d27\u53f7\u4e3a00-4333-57\u7684\u88c2\u89e3\u6db2\uff0c\u6ce8\u610f\u4f7f\u7528\u524d\u9700\u8981\u8fc7\u6ee4\u9664\u83cc\uff09\u3002\u6709\u4e00\u4e9b\u7279\u6b8a\u60c5\u51b5\uff0c\u5982\u9aa8\u9ad3\u7c92\u7ec6\u80de\u5206\u79bb\uff0c\u4e3a\u4e86\u4e0d\u6fc0\u6d3b\u7c92\u7ec6\u80de\uff0c\u5219\u9700\u8981\u7528\u7279\u6b8a\u7684\u88c2\u89e3\u65b9\u5f0f\u7ed3\u5408\u5bc6\u5ea6\u68af\u5ea6\u79bb\u5fc3\u7684\u65b9\u6cd5\uff0c\u53ef\u4ee5\u770b\u770b\u6587\u732e\u30103\u3011\u54e6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u6211\u8be5\u7528\u591a\u5927\u5468\u9f84\u7684\u5c0f\u9f20\u5206\u79bb\u9aa8\u9ad3\u7ec6\u80de\u5462\uff1f\u83b7\u53d6\u7684\u7ec6\u80de\u6570\u91cf\u5728\u4ec0\u4e48\u6570\u91cf\u7ea7\u662f\u6b63\u5e38\u7684\u5462\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u4e00\u822c\u4f7f\u7528\u6210\u5e74\u5c0f\u9f20\u8fdb\u884c\u5b9e\u9a8c\uff0c\u81f3\u5c11\u9700\u8981\u5927\u4e8e6\u5468\u3002\u5982\u679c\u6709\u7279\u6b8a\u7684\u75be\u75c5\u6a21\u578b\uff0c\u5219\u9700\u8981\u8fdb\u4e00\u6b65\u53c2\u8003\u6587\u732e\u5e76\u7ed3\u5408\u5b9e\u9a8c\u6478\u7d22\u3002\u6587\u732e\u62a5\u9053\uff0c\u5bf9\u4e8eC57BL\/6 \u8fd9\u4e2a\u54c1\u7cfb\u7684\u5c0f\u9f20\uff0c\u6536\u96c6\u4e24\u6839\u80a1\u9aa8\u5e76\u88c2\u89e3\u7ea2\u7ec6\u80de\u540e\uff0c\u7ea6\u670910<sup>7<\/sup>-10<sup>8<\/sup>\u4e2a\u9aa8\u9ad3\u7ec6\u80de\u3002\u5f53\u7136\uff0c\u4e0d\u540c\u5468\u9f84\u3001\u54c1\u7cfb\u548c\u6a21\u578b\u5728\u6570\u91cf\u4e0a\u8fd8\u4f1a\u6709\u5dee\u5f02\u7684\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u6587\u732e\"><strong>\u53c2\u8003\u6587\u732e\uff1a<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">[1] Immune Cell Isolation from Mouse Femur Bone Marrow<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] An improved protocol for isolation and culture of mesenchymal stem cells from mouse bone marrow<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3] Isolation, Purification and Labeling of Mouse Bone Marrow Neutrophils for Functional Studies and Adoptive Transfer Experiments<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de[1]\u3002\u6b64\u5916\uff0c<\/p>\n","protected":false},"author":1852,"featured_media":1161,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[],"division":[9],"class_list":["post-1151","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb\" \/>\n<meta property=\"og:description\" content=\"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T09:09:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1360\" \/>\n\t<meta property=\"og:image:height\" content=\"806\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb\",\"datePublished\":\"2026-03-24T09:09:04+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/\"},\"wordCount\":106,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-214956@2x.png\",\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/\",\"name\":\"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-214956@2x.png\",\"datePublished\":\"2026-03-24T09:09:04+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-214956@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-214956@2x.png\",\"width\":1360,\"height\":806},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/mouse-bone-marrow-cell-isolation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/","og_locale":"zh_CN","og_type":"article","og_title":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb","og_description":"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-24T09:09:04+00:00","article_modified_time":"2026-04-22T21:59:28+00:00","og_image":[{"width":1360,"height":806,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb","datePublished":"2026-03-24T09:09:04+00:00","dateModified":"2026-04-22T21:59:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/"},"wordCount":106,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png","articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/","name":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png","datePublished":"2026-03-24T09:09:04+00:00","dateModified":"2026-04-22T21:59:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u9aa8\u9ad3\u662f\u9020\u8840\u7684\u573a\u6240\uff0c\u53ef\u5206\u79bb\u51fa\u7ea2\u7ec6\u80de\u3001\u7c92\u7ec6\u80de\u3001\u5355\u6838\u7ec6\u80de\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u3001\u6dcb\u5df4\u7ec6\u80de\u548c\u9020\u8840\u5e72\u7ec6\u80de\u7b49\u8840\u6e90\u6027\u7ec6\u80de\u3002\u6b64\u5916\uff0c\u9aa8\u9ad3\u4e5f\u53ef\u4ee5\u4f5c\u4e3a\u5145\u8d28\u5e72\u7ec6\u80de\u7684\u6765\u6e90\u3002\u5206\u79bb\u540e\u7684\u9aa8\u9ad3\u7ec6\u80de\u5e94\u7528\u975e\u5e38\u5e7f\u6cdb\uff0c\u4f8b\u5982\u76f4\u63a5\u7528\u4e8e\u9aa8\u9ad3\u79fb\u690d\uff0c\u6d41\u5f0f\u7ec6\u80de\u672f\u5206\u6790\u9020\u8840\u5e72\u7ec6\u80de\u4e9a\u7fa4\u4ee5\u53ca\u5404\u6dcb\u5df4\u7ec6\u80de\u4e9a\u7fa4\uff0c\u6216\u8005\u8fdb\u884c\u5de8\u566c\u7ec6\u80de\u6781\u5316\u3001\u6811\u7a81\u72b6\u7ec6\u80de\u5206\u5316\u7b49\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x.png","width":1360,"height":806},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/mouse-bone-marrow-cell-isolation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u5c0f\u9f20\u9aa8\u9ad3\u7ec6\u80de\u5206\u79bb"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-214956@2x-1024x607.png",760,451,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1151"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1151\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1161"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1151"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1151"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1151"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}