{"id":1163,"date":"2026-03-24T09:19:42","date_gmt":"2026-03-24T09:19:42","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1163"},"modified":"2026-04-22T21:59:27","modified_gmt":"2026-04-22T21:59:27","slug":"spleen-sample-preparation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/","title":{"rendered":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u63d0\u5230\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\uff0c\u76f8\u4fe1\u5f88\u591a\u540c\u5b66\u4eec\u90fd\u4f1a\u4e0d\u4ee5\u4e3a\u610f\u3002\u60f3\u5f53\u521dDr.\u8d5b\u5728\u505a\u535a\u58eb\u751f\u7684\u65f6\u5019\uff0c\u7ecf\u624b\u813e\u810f\u65e0\u6570\uff0c\u81ea\u8ba4\u4e3a\u7ecf\uff08Ye\uff09\u9a8c\uff08Lang\uff09\u4e30\uff08Zi\uff09\u5bcc\uff08Da\uff09\uff0c\u5bf9\u8fd9\u4e2a\u95ee\u9898\u4e5f\u4f1a\u55e4\u4e4b\u4ee5\u9f3b\uff0c\u8fd9\u6709\u4ec0\u4e48\u96be\u7684\uff1f\uff1f\u8fd9\u8fd8\u80fd\u51fa\u4ec0\u4e48\u95ee\u9898\uff1f\uff1f\u4eca\u5929Dr.\u8d5b\u5c31\u5e26\u7740\u540c\u5b66\u4eec\u6765\u634b\u4e00\u634b<strong>\u90a3\u4e9b\u5e74\u6211\u4eec\u6389\u8fc7\u7684\u5751<\/strong>\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u603b\u4f53\u6765\u8bf4\uff0c\u813e\u810f\u6837\u672c\u5236\u5907\u5171\u5206\u4ee5\u4e0b\u56db\u6b65\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"362\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1-1024x362.png\" alt=\"\" class=\"wp-image-1166\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1-1024x362.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1-300x106.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1-768x271.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1.png 1342w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e00\u6b65-\u6458\u53d6\u813e\u810f\"><strong>\u7b2c\u4e00\u6b65\uff0c\u6458\u53d6\u813e\u810f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7b2c\u4e00\u6b21\u505a\u5b9e\u9a8c\uff0c\u6ca1\u627e\u5230\u813e\u810f\u7684\u540c\u5b66\uff0c\u8bf7\u9ed8\u9ed8\u4e3e\u8d77\u4f60\u7684\u5c0f\u624b\uff01\u5c0f\u9f20\u7684\u813e\u810f\u4f4d\u4e8e\u8179\u8154\u5de6\u4e0a\u65b9\uff0c\u7d27\u9760\u80c3\u5e95\u90e8\u7684\u5de6\u4fa7\uff0c\u7ea2\u7d2b\u8272\uff0c\u5448\u957f\u6761\u5f62\uff08\u56fe1\u548c\u56fe2\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8179\u8154\u6253\u5f00\u4e4b\u540e\uff0c\u53ef\u4ee5\u4f7f\u7528\u954a\u5b50\u5c06\u813e\u810f\u6458\u53d6\u51fa\u6765\uff0c\u65b0\u624b\u5efa\u8bae\u4f7f\u7528\u5f2f\u5934\u954a\u5b50\uff0c\u4e0d\u5bb9\u6613\u523a\u7a7f\u813e\u810f\u3002\u813e\u810f\u53d6\u51fa\u6765\u4e4b\u540e\uff0c\u7f6e\u4e8eRPMI 1640\u5b8c\u5168\u57f9\u517b\u57fa\uff08RPMI 1640\u57fa\u7840\u57f9\u517b\u57fa + 10%\u80ce\u725b\u8840\u6e05&nbsp;+ 1%\u4e19\u916e\u9178\u94a0\uff09\u5907\u7528\u3002\u5982\u679c\u5206\u79bb\u7684\u813e\u810f\u7ec6\u80de\u8fd8\u9700\u8981\u57f9\u517b\uff0c\u53ef\u4ee5\u8003\u8651\u5728\u5b8c\u5168\u57f9\u517b\u57fa\u4e2d\u6dfb\u52a0\u53cc\u6297\uff0c\u964d\u4f4e\u7ec6\u80de\u6c61\u67d3\u7684\u53ef\u80fd\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"726\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220359@2x-1024x726.png\" alt=\"\" class=\"wp-image-1167\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220359@2x-1024x726.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220359@2x-300x213.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220359@2x-768x545.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220359@2x.png 1438w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe1. \u5c0f\u9f20\u6dcb\u5df4\u7ed3\u548c\u813e\u810f\u5206\u5e03\u793a\u610f\u56fe\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe\u7247\u51fa\u5904\uff1aToribio-Fernandez R, Zorita V, Herrero-Fernandez B, Gonzalez-Granado JM. An In Vivo Mouse Model to Measure Na\u00efve CD4 T Cell Activation, Proliferation and Th1 Differentiation Induced by Bone Marrow-derived Dendritic Cells. J Vis Exp. 2018 Aug 22;(138):58118. doi: 10.3791\/58118.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"812\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220410@2x-1024x812.png\" alt=\"\" class=\"wp-image-1168\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220410@2x-1024x812.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220410@2x-300x238.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220410@2x-768x609.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220410@2x.png 1388w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u56fe2. \u813e\u810f\u5728\u57f9\u517b\u57fa\u4e2d\u7684\u793a\u610f\u56fe\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe\u7247\u51fa\u5904\uff1aHarada Y, Miyamoto K, Sujino T. Protocol to isolate and enrich mouse splenic naive CD4+ T cells for in vitro CD4+CD8\u03b1\u03b1+ cell induction. STAR Protoc. 2022 Dec 16;3(4):101728. doi: 10.1016\/j.xpro.2022.101728.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e8c\u6b65-\u5904\u7406\u813e\u810f\"><strong>\u7b2c\u4e8c\u6b65\uff0c\u5904\u7406\u813e\u810f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5904\u7406\u813e\u810f\u6700\u5e38\u7528\u7684\u662f\u673a\u68b0\u89e3\u79bb\u7684\u65b9\u6cd5\uff0c\u4e3b\u8981\u7684\u65b9\u5f0f\u5c31\u662f\u7814\u78e8\u3002\u5177\u4f53\u6765\u8bf4\uff0c\u5c0670\u5fae\u7c73\u7ec6\u80de\u7b5b\u7f51\u653e\u5728 50 mL\u79bb\u5fc3\u7ba1\u4e0a\u65b9\uff0c\u5c06\u813e\u810f\u8f6c\u79fb\u5230\u7ec6\u80de\u7b5b\u7f51\u4e2d\uff0c\u4f7f\u7528\u6ce8\u5c04\u5668\u67f1\u585e\u7aef\uff0c\u6363\u788e\u6216\u538b\u788e\u813e\u810f\uff0c\u4f7f\u5176\u901a\u8fc7\u7b5b\u7f51\uff0c\u7136\u540e\u4f7f\u7528\u79fb\u6db2\u5668\u5439\u6253\u5747\u5300\uff0c\u5f97\u5230\u813e\u810f\u7ec6\u80de\u60ac\u6db2\u3002\u6587\u732e\u4e2d\u8fd8\u6709\u4f7f\u7528\u9176\u6d88\u5316\u7684\u65b9\u5f0f\u6765\u8fdb\u884c\u813e\u810f\u7ec6\u80de\u89e3\u79bb\uff0c\u5bf9\u4e8e\u67d0\u4e9b\u7279\u5b9a\u7ec6\u80de\u7c7b\u578b\uff0c\u6bd4\u5982\u6811\u7a81\u72b6\u7ec6\u80de\uff0c\u9176\u6d88\u5316\u7684\u65b9\u5f0f\u80fd\u591f\u6539\u5584\u6811\u7a81\u72b6\u7ec6\u80de\u7684\u91ca\u653e\u548c\u5f97\u7387\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7b2c\u4e09\u6b65-\u88c2\u89e3\u7ea2\u7ec6\u80de\"><strong>\u7b2c\u4e09\u6b65\uff0c\u88c2\u89e3\u7ea2\u7ec6\u80de<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c0f\u9f20\u813e\u810f\u4e2d\u542b\u6709\u7ea62.5-5\u00d710<sup>10<\/sup>&nbsp;\u7ea2\u7ec6\u80de\uff0c\u800c\u767d\u7ec6\u80de\u53ea\u6709\u7ea61\u00d710<sup>8<\/sup>\u3002\u4e3a\u4e86\u51cf\u5c11\u7ea2\u7ec6\u80de\u5bf9\u4e8e\u767d\u7ec6\u80de\u5206\u6790\u53ef\u80fd\u4ea7\u751f\u7684\u5f71\u54cd\uff0c\u901a\u5e38\u4f1a\u9009\u62e9\u4f7f\u7528\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u5c06\u7ea2\u7ec6\u80de\u53bb\u9664\u3002\u6bd4\u8f83\u5e38\u7528\u7684\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u662f\u4ee5\u6c2f\u5316\u94f5\u4e3a\u4e3b\u8981\u6210\u5206\uff0c\u901a\u8fc7\u6539\u53d8\u6e17\u900f\u538b\uff0c\u5c06\u7ea2\u7ec6\u80de\u6da8\u7834\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dr.\u8d5b\u5c06\u813e\u810f\u7ec6\u80de\u6c34\u5e73\u79bb\u5fc3\u6536\u96c6\uff08400\u00d7g\uff0c5\u5206\u949f\uff09\u5e76\u91cd\u60ac\u4e8e5 mL\u7684\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u4e2d\uff08eBioscience\u2122 1X \u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\uff0c\u8d27\u53f7: 00-4333-57\uff09\uff0c\u51b0\u4e0a\u5b75\u80b24-5\u5206\u949f\uff0c\u7ec8\u6b62\u53cd\u5e94\u540e\uff0c\u7ec6\u80de\u901a\u8fc7\u79bb\u5fc3\u6536\u96c6\uff0c\u91cd\u60ac\u4e8eRPMI 1640\u5b8c\u5168\u57f9\u517b\u57fa\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7ea2\u7ec6\u80de\u88c2\u89e3\u8fc7\u7a0b\u4e2d\u7684\u5e38\u89c1\u95ee\u9898\"><strong>\u7ea2\u7ec6\u80de\u88c2\u89e3\u8fc7\u7a0b\u4e2d\u7684\u5e38\u89c1\u95ee\u9898\uff1a<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u603b\u662f\u4f1a\u6b8b\u7559\u5c11\u91cf\u7ea2\u7ec6\u80de\uff0c\u662f\u5426\u9700\u8981\u88c2\u89e3\u5b8c\u5168\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u7ea2\u7ec6\u80de\u88c2\u89e3\u5b8c\u5168\u901a\u5e38\u662f\u4e0d\u5fc5\u8981\u7684\uff0c\u4e00\u65b9\u9762\u5c11\u91cf\u6b8b\u7559\u7ea2\u7ec6\u80de\u901a\u5e38\u4e0d\u4f1a\u5e72\u6270\u540e\u7eed\u5b9e\u9a8c\uff0c\u5e76\u4e14\u53ef\u4ee5\u5728\u6d41\u5f0f\u5206\u6790\u8fc7\u7a0b\u4e2d\u88ab\u5206\u6790\u51fa\u6765\u3002\u53e6\u4e00\u65b9\u9762\uff0c\u5b8c\u5168\u88c2\u89e3\u7ea2\u7ec6\u80de\u5f80\u5f80\u9700\u8981\u5ef6\u957f\u88c2\u7ea2\u65f6\u95f4\uff0c\u589e\u52a0\u88c2\u7ea2\u6b21\u6570\u7b49\uff0c\u8fd9\u6837\u53ef\u80fd\u4f1a\u5bf9\u767d\u7ec6\u80de\u9020\u6210\u4e00\u5b9a\u7684\u5f71\u54cd\u3002\u5982\u679c\u786e\u5b9e\u9700\u8981\u8fdb\u4e00\u6b65\u53bb\u9664\u7ea2\u7ec6\u80de\uff0c\u53ef\u4ee5\u518d\u6b21\u7528\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u5b75\u80b2\u6837\u672c\u8fdb\u884c\u4e8c\u6b21\u88c2\u7ea2\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u7ea2\u7ec6\u80de\u88c2\u89e3\u79bb\u5fc3\u540e\uff0c\u53d1\u73b0\u6709\u4e00\u56e2\u7ec6\u80de\uff0c\u65e0\u6cd5\u5439\u6253\u5206\u6563\uff0c\u8fd9\u662f\u600e\u4e48\u56de\u4e8b\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u8fd9\u662f\u7ea2\u7ec6\u80de\u88c2\u89e3\u540e\u6bd4\u8f83\u5e38\u89c1\u7684\u73b0\u8c61\uff0c\u8fd9\u4e00\u56e2\u7ec6\u80de\u4ee5\u6b7b\u7ec6\u80de\u4e3a\u4e3b\uff0c\u7ec6\u80de\u6b7b\u4ea1\u9020\u6210\u6838\u9178\u91ca\u653e\uff0c\u800c\u6838\u9178\u6bd4\u8f83\u201c\u7c98\u201d\uff0c\u4ece\u800c\u5f62\u6210\u7ec6\u80de\u56e2\u3002\u88c2\u7ea2\u79bb\u5fc3\u4e4b\u540e\uff0c\u9700\u8981\u8fc7\u6ee4\u53bb\u9664\u7ec6\u80de\u56e2\u3002\u5982\u679c\u4e0d\u53bb\u9664\u7684\u8bdd\uff0c\u53ef\u80fd\u4f1a\u5f62\u6210\u201c\u6eda\u96ea\u7403\u201d\u6548\u5e94\uff0c\u7c98\u9644\u7684\u7ec6\u80de\u8d8a\u6765\u8d8a\u591a\uff0c\u7ec6\u80de\u56e2\u4e5f\u5c31\u8d8a\u6765\u8d8a\u5927\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u662f\u65e0\u83cc\u7684\u5417\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u8fd9\u8981\u770b\u5177\u4f53\u7684\u4ea7\u54c1\uff0c\u975e\u65e0\u83cc\u7684\u88c2\u89e3\u6db2\u53ef\u4ee5\u81ea\u884c\u8fc7\u6ee4\u9664\u83cc\uff080.2\u5fae\u7c73\u6ee4\u819c\uff09\uff0c\u4e5f\u53ef\u4ee5\u9009\u62e9\u65e0\u83cc\u8fc7\u6ee4\u7684ACK\u88c2\u89e3\u6db2\uff0c\u8d27\u53f7A1049201\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7b2c\u56db\u6b65-\u7ec6\u80de\u8ba1\u6570\"><strong>\u7b2c\u56db\u6b65\uff0c\u7ec6\u80de\u8ba1\u6570<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u88c2\u8fc7\u7ea2\u7684\u813e\u810f\u7ec6\u80de\u4e2d\u4ee5T\u548cB\u6dcb\u5df4\u7ec6\u80de\u4e3a\u4e3b\uff0c\u4e2a\u5934\u53c8\u5c0f\uff0c\u6570\u91cf\u53c8\u591a\uff0c\u4eba\u5de5\u8ba1\u6570\u5b9e\u5728\u662f\u6709\u70b9\u56f0\u96be\u3002\u73b0\u5728\uff0cDr.\u8d5b\u4f7f\u7528\u7684\u662f<strong>Countess\u2122 3 FL\u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u5668<\/strong>\u8fdb\u884c\u7ec6\u80de\u8ba1\u6570\uff0c\u53c8\u5feb\u53c8\u51c6\uff0c\u7701\u65f6\u7701\u529b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5c0f\u9f20\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5e38\u89c1\u95ee\u9898\"><strong>\u5c0f\u9f20\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5e38\u89c1\u95ee\u9898\uff1a<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u5c0f\u9f20\u813e\u810f\u4e2d\u6709\u9ed1\u6591\uff0c\u662f\u4e0d\u662f\u5c0f\u9f20\u751f\u75c5\u4e86\uff0c\u8fd9\u4e2a\u813e\u810f\u8fd8\u80fd\u4e0d\u80fd\u7528\u4e86\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u4ee5Dr.\u8d5b\u672c\u4eba\u7684\u7ecf\u9a8c\u6765\u770b\uff0c\u6709\u9ed1\u6591\u548c\u6ca1\u6709\u9ed1\u6591\u7684\u813e\u810f\uff0c\u6ca1\u6709\u53d1\u73b0\u6709\u660e\u663e\u7684\u7ec6\u80de\u7ec4\u6210\u53d8\u5316\u3002\u540c\u65f6\uff0cDr.\u8d5b\u4e5f\u67e5\u9605\u4e86\u5f88\u591a\u76f8\u5173\u6587\u732e\uff0c\u76ee\u524d\u8ba4\u4e3a\uff0c\u9ed1\u6591\u662f\u7531\u4e8e\u9ed1\u8272\u7d20\u6c89\u79ef\u9020\u6210\u7684\uff0c\u5bf9\u514d\u75ab\u5b66\u7814\u7a76\u672a\u53d1\u73b0\u6709\u663e\u8457\u5f71\u54cd\uff0c\u65e0\u9700\u8fc7\u591a\u62c5\u5fc3\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u63d0\u5230\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\uff0c\u76f8\u4fe1\u5f88\u591a\u540c\u5b66\u4eec\u90fd\u4f1a\u4e0d\u4ee5\u4e3a\u610f\u3002\u60f3\u5f53\u521dDr.\u8d5b\u5728\u505a\u535a\u58eb\u751f\u7684\u65f6\u5019\uff0c\u7ecf\u624b\u813e\u810f\u65e0\u6570\uff0c\u81ea\u8ba4\u4e3a\u7ecf\uff08<\/p>\n","protected":false},"author":1852,"featured_media":1165,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[],"division":[9],"class_list":["post-1163","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\" \/>\n<meta property=\"og:description\" content=\"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T09:19:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1342\" \/>\n\t<meta property=\"og:image:height\" content=\"474\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\",\"datePublished\":\"2026-03-24T09:19:42+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/\"},\"wordCount\":104,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-220336@2x.png\",\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/\",\"name\":\"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-220336@2x.png\",\"datePublished\":\"2026-03-24T09:19:42+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-220336@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-220336@2x.png\",\"width\":1342,\"height\":474},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/spleen-sample-preparation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/","og_locale":"zh_CN","og_type":"article","og_title":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907","og_description":"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-24T09:19:42+00:00","article_modified_time":"2026-04-22T21:59:27+00:00","og_image":[{"width":1342,"height":474,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907","datePublished":"2026-03-24T09:19:42+00:00","dateModified":"2026-04-22T21:59:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/"},"wordCount":104,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png","articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/","name":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png","datePublished":"2026-03-24T09:19:42+00:00","dateModified":"2026-04-22T21:59:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u8d5b\u9ed8\u98de\u5e26\u7740\u5927\u5bb6\u6765\u634b\u4e00\u634b\u5c0f\u9f20\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907\u7684\u5751\uff0c\u770b\u770b\u8fd9\u91cc\u9762\u6709\u6ca1\u6709\u4f60\u719f\u6089\u7684\u5751\uff01","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x.png","width":1342,"height":474},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/spleen-sample-preparation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u6d41\u5f0f\u813e\u810f\u6837\u672c\u5236\u5907"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-220336@2x-1024x362.png",760,269,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1163"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1163\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1165"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1163"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1163"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1163"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}