{"id":1194,"date":"2026-03-25T07:22:19","date_gmt":"2026-03-25T07:22:19","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1194"},"modified":"2026-04-22T21:59:27","modified_gmt":"2026-04-22T21:59:27","slug":"quantum-dots","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/quantum-dots\/","title":{"rendered":"\u91cf\u5b50\u70b9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u8fd12023\u5e74\u8bfa\u8d1d\u5c14\u5316\u5b66\u5956\u5df2\u7ecf\u63ed\u79d8\uff0c\u8499\u5409\u00b7\u5df4\u6587\u8fea\u3001\u8def\u6613\u65af\u00b7\u5e03\u9c81\u65af\u548c\u963f\u5217\u514b\u8c22\u00b7\u53f6\u57fa\u83ab\u592b\u4e09\u4f4d\u79d1\u5b66\u5bb6\u56e0\u4ed6\u4eec\u5728\u53d1\u73b0\u548c\u5408\u6210<strong>\u91cf\u5b50\u70b9\uff08Quantum dots\uff09<\/strong>\u65b9\u9762\u6240\u4f5c\u51fa\u7684\u8d21\u732e\u5171\u540c\u5206\u4eab\u4e86\u8fd9\u4e00\u5956\u9879\uff08Figure 1\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"980\" height=\"978\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1.png\" alt=\"\" class=\"wp-image-1196\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1.png 980w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1-300x300.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1-150x150.png 150w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1-768x766.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x-1-80x80.png 80w\" sizes=\"auto, (max-width: 980px) 100vw, 980px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure&nbsp;1. 2023\u8bfa\u8d1d\u5c14\u5316\u5b66\u5956<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u90a3\u4e48<strong>\u91cf\u5b50\u70b9<\/strong>\u5230\u5e95\u662f\u4ec0\u4e48\u5462\uff0c\u4eca\u5929Dr.\u8d5b\u5c31\u5e26\u7740\u540c\u5b66\u4eec\u6765\u4e00\u63a2\u7a76\u7adf\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u91cf\u5b50\u70b9\u7684\u6982\u5ff5\u53ca\u7279\u6027\"><strong>\u91cf\u5b50\u70b9\u7684\u6982\u5ff5\u53ca\u7279\u6027<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u91cf\u5b50\u70b9<\/strong>\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282<strong>\u7c92\u5f84\u5927\u5c0f<\/strong>\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\uff08Figure 2\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"658\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223315@2x-1024x658.png\" alt=\"\" class=\"wp-image-1197\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223315@2x-1024x658.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223315@2x-300x193.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223315@2x-768x493.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223315@2x.png 1068w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure&nbsp;2. \u91cf\u5b50\u70b9\u7684\u7ed3\u6784\u548c\u4e0d\u540c\u5c3a\u5bf8\u5927\u5c0f\u7684\u53d1\u5c04\u6ce2\u957f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u91cf\u5b50\u70b9\u7684\u7279\u70b9\u6709\u65af\u6258\u514b\u65af\u4f4d\u79fb\u5927\u3001<strong>\u6fc0\u53d1\u5149\u8c31\u5bbd\u800c\u53d1\u5c04\u5149\u8c31\u7a84\u3001\u8367\u5149\u5f3a\u5ea6\u548c\u7a33\u5b9a\u6027\u9ad8<\/strong>\u548c\u8f83\u597d\u7684\u751f\u7269\u76f8\u5bb9\u6027\uff0c\u8fd9\u4f7f\u5f97\u5176\u5728\u751f\u7269\u6210\u50cf\u65b9\u9762\u5360\u6709\u4e00\u5e2d\u4e4b\u5730\uff0c\u76f8\u8f83\u4e8e\u4f20\u7edf\u5c0f\u5206\u5b50\u8367\u5149\u67d3\u6599\u5728\u6210\u50cf\u4e2d\u5448\u73b0\u7684\u5bb9\u6613\u6dec\u706d\u3001\u8367\u5149\u5f31\u7b49\u60c5\u51b5\uff0c\u91cf\u5b50\u70b9\u901a\u5e38\u5c55\u73b0\u51fa\u66f4\u597d\u7684\u6210\u50cf\u6548\u679c\u3002\u5c24\u5176\u9488\u5bf9\u4e8e\u4f53\u5185\u6210\u50cf\u8fd9\u79cd\u672c\u8eab\u5177\u6709\u81ea\u53d1\u8367\u5149\u80cc\u666f\u7684\u60c5\u51b5\uff0c\u91cf\u5b50\u70b9\u4e5f\u80fd\u5c55\u73b0\u9ad8\u4fe1\u80cc\u6bd4\u7684\u6210\u50cf\u6548\u679c\uff08Figure 3\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"432\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223349@2x-1024x432.png\" alt=\"\" class=\"wp-image-1198\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223349@2x-1024x432.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223349@2x-300x127.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223349@2x-768x324.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223349@2x.png 1066w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure 3. \u80da\u80ce\u5e72\u7ec6\u80de\u6807\u8bb0\u540e\u76ae\u4e0b\u6ce8\u5c04\u81f3\u88f8\u9f20\u80cc\u90e8\u5355\u6fc0\u53d1\u8367\u5149\u6210\u50cf\u56fe\uff08A\uff09\u548c\u8367\u5149\u91cf\u5316\u6570\u636e\uff08B\uff09<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u91cf\u5b50\u70b9\u751f\u7269\u5b66\u5e94\u7528\"><strong>\u91cf\u5b50\u70b9\u751f\u7269\u5b66\u5e94\u7528<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u91cf\u5b50\u70b9\u8367\u5149\u7a33\u5b9a\u6027\u5f3a<\/strong>\uff0c\u5e38\u88ab\u5e94\u7528\u4e8e\u7ec6\u80de\u6210\u50cf\u548c\u4f53\u5185\u6210\u50cf\uff0c\u6839\u636e\u8367\u5149\u5f3a\u5ea6\u7684\u53d8\u5316\u8fd8\u53ef\u4ee5\u7528\u4e8e\u68c0\u6d4b\u591a\u79cd\u79bb\u5b50\uff08K+\u3001Fe3+\u3001ONOO-\uff09\u3001\u836f\u7269\u5206\u5b50\uff08\u56db\u73af\u7d20\u3001\u6297\u751f\u7d20\u3001\u7532\u6c28\u8776\u5464\uff09\u3001\u751f\u7269\u5206\u5b50\uff08DNA\u3001\u86cb\u767d\u8d28\u3001\u80c6\u56fa\u9187\uff09\u3001pH\u503c\u7b49\uff0c\u91cf\u5b50\u70b9\u8868\u9762\u7ecf\u8fc7\u4fee\u9970\u540e\u8fd8\u80fd\u5bf9\u836f\u7269\u8fdb\u884c\u9012\u9001\uff0c\u88ab\u5e7f\u6cdb\u5e94\u7528\u4e8e\u9776\u5411\u6cbb\u7597\u3001\u5149\u52a8\u529b\u548c\u5149\u70ed\u6cbb\u7597\u3001\u514d\u75ab\u5b66\u548c\u57fa\u56e0\u6cbb\u7597\u7b49\uff08Figure 4\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"723\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223429@2x-1024x723.png\" alt=\"\" class=\"wp-image-1199\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223429@2x-1024x723.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223429@2x-300x212.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223429@2x-768x543.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223429@2x.png 1104w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure 4. \u91cf\u5b50\u70b9\u7684\u591a\u79cd\u751f\u7269\u5b66\u5e94\u7528<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u91cf\u5b50\u70b9\u5de5\u5177\u7bb1\"><strong>\u91cf\u5b50\u70b9\u5de5\u5177\u7bb1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u91cf\u5b50\u70b9\u8868\u9762\u7ecf\u8fc7\u4e0d\u540c\u7ed3\u6784\u4fee\u9970\u540e\u80fd\u5b9e\u73b0\u548c\u751f\u7269\u5206\u5b50\u8fdb\u884c\u7279\u5f02\u6027\u5076\u8054\uff0c\u6ee1\u8db3\u67d0\u4e9b\u7279\u5b9a\u9776\u6807\u7684\u6807\u8bb0\u793a\u8e2a\u53ca\u68c0\u6d4b\u5b9e\u9a8c\u7684\u9700\u8981\u3002\u6839\u636e\u548c\u751f\u7269\u5206\u5b50\u5076\u8054\u65b9\u5f0f\u4e0d\u540c\uff0c\u53ef\u4ee5\u5206\u4e3a<strong>\u5171\u4ef7\u7ed3\u5408<\/strong>\u548c<strong>\u975e\u5171\u4ef7\u7ed3\u5408<\/strong>\u4e24\u79cd\uff0c\u5728\u5171\u4ef7\u7ed3\u5408\u4e2d\uff0c\u91cf\u5b50\u70b9\u8868\u9762\u7528\u6d3b\u6cfc\u57fa\u56e2\u4fee\u9970\u53ef\u4ee5\u4e0e\u542b\u6709\u6e38\u79bb\u6c28\u57fa\u6216\u7fa7\u57fa\u7684\u751f\u7269\u5206\u5b50\u7ed3\u5408\uff1b\u800c\u5728\u975e\u5171\u4ef7\u7ed3\u5408\u4e2d\uff0c\u901a\u5e38\u662f\u91cf\u5b50\u70b9\u8868\u9762\u5e26\u6709\u7684\u7535\u8377\u4e0e\u751f\u7269\u5206\u5b50\u901a\u8fc7\u9759\u7535\u76f8\u4e92\u4f5c\u7528\u6216\u9ad8\u4eb2\u548c\u529b\u76f8\u4e92\u4f5c\u7528\u76f8\u7ed3\u5408\u3002\u91cf\u5b50\u70b9\u4ea7\u54c1\u6570\u91cf\u5f88\u591a\uff0c\u6839\u636e\u5177\u4f53\u7684\u5b9e\u9a8c\u76ee\u7684\u53ef\u4ee5\u9009\u62e9\u5bf9\u5e94\u7684\u4ea7\u54c1\u6765\u6ee1\u8db3\u4e0d\u540c\u7684\u5b9e\u9a8c\u9700\u6c42\uff08Table 1\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table&nbsp;1.&nbsp;\u6ee1\u8db3\u4e0d\u540c\u5b9e\u9a8c\u76ee\u7684\u7684\u91cf\u5b50\u70b9\u4ea7\u54c1<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"650\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223520@2x-1024x650.png\" alt=\"\" class=\"wp-image-1200\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223520@2x-1024x650.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223520@2x-300x190.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223520@2x-768x487.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223520@2x.png 1050w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-faq\"><strong>FAQ<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q Qdot\u7eb3\u7c73\u6676\u4f53\u7684\u57fa\u672c\u7ed3\u6784\u5982\u4f55\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> Qdot\u7eb3\u7c73\u6676\u4f53\u7531\u6676\u6838\u3001\u65e0\u673a\u5c42\u3001\u6709\u673a\/\u805a\u5408\u7269\u6d82\u5c42\u548c\u751f\u7269\u5206\u5b50\u6784\u6210\u3002\u6676\u6838\u901a\u5e38\u51b3\u5b9a\u4e86Qdot\u7684\u989c\u8272\uff0c\u65e0\u673a\u5c42\u7528\u4e8e\u63d0\u9ad8Qdot\u7684\u4eae\u5ea6\u548c\u7a33\u5b9a\u6027\uff0c\u6709\u673a\/\u805a\u5408\u7269\u6d82\u5c42\u63d0\u4f9b\u6c34\u6eb6\u6027\u548c\/\u6216\u7528\u4e8e\u5076\u8054\u7684\u5b98\u80fd\u56e2\uff0c\u751f\u7269\u5206\u5b50\u5219\u662f\u8d1f\u8d23\u5171\u4ef7\u7ed3\u5408\u5230\u805a\u5408\u7269\u5c42\uff0c\u5305\u62ec\u4e00\u4e9b\u514d\u75ab\u7403\u86cb\u767d\u3001\u94fe\u9709\u4eb2\u548c\u7d20\u3001\u53d7\u4f53\u914d\u4f53\u6216\u5be1\u6838\u82f7\u9178\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q Qdot\u76f8\u8f83\u4e8e\u4f20\u7edf\u8367\u5149\u67d3\u6599\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u76f8\u8f83\u4e8e\u4f20\u7edf\u5c0f\u5206\u5b50\u8367\u5149\u67d3\u6599\u5149\u8c31\u91cd\u53e0\u4e25\u91cd\uff0c\u5e72\u6270\u660e\u663e\u7684\u73b0\u8c61\uff0c\u91cf\u5b50\u70b9\u6210\u50cf\u5177\u6709\u4f4e\u80cc\u666f\u3001\u4fe1\u566a\u6bd4\u9ad8\u7684\u7279\u70b9\uff0c\u5e76\u4e14\u53ef\u4ee5\u5b9e\u73b0\u4f7f\u7528\u540c\u4e00\u6fc0\u53d1\u5149\u540c\u65f6\u6fc0\u53d1\u591a\u79cd\u91cf\u5b50\u70b9\u91ca\u653e\u51fa\u4e0d\u540c\u6ce2\u957f\u7684\u8367\u5149\uff0c\u56e0\u800c\u80fd\u591f\u7528\u4e8e\u591a\u79cd\u6807\u8bb0\u7269\u7684\u540c\u65f6\u68c0\u6d4b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q Qdot\u7eb3\u7c73\u6676\u4f53\u4fdd\u6301\u7a33\u5b9a\u7684pH\u8303\u56f4\u662f\u591a\u5c11\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>Qdot\u7eb3\u7c73\u6676\u4f53\u5728pH6-9\u7684\u8303\u56f4\u5185\u6700\u7a33\u5b9a\uff0c\u6700\u4f4e\u81f3pH 5\u3002\u7531\u4e8e\u53ef\u80fd\u5b58\u5728\u81ea\u805a\u96c6\uff0cQdot\u7eb3\u7c73\u6676\u4f53\u4e0d\u80fd\u5728pH &gt; 9\u6216pH &lt; 4\u7684\u6761\u4ef6\u4e0b\u4f7f\u7528\uff0c\u5426\u5219\u805a\u5408\u7269\u548c\u66b4\u9732\u7684\u6838\/\u58f3\u4f1a\u5f00\u59cb\u5206\u79bb\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u6211\u6ca1\u6709\u4e13\u95e8\u4f18\u5316\u7684\u6ee4\u7247\u6765\u89c2\u5bdfQdot\u7eb3\u7c73\u6676\u4f53\uff0c\u80fd\u591f\u7528\u6807\u51c6\u6ee4\u5149\u7247\u89c2\u5bdf\u5417\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5f53\u7136\u53ef\u4ee5\uff0c\u540c\u65f6\u53ef\u4ee5\u4f7f\u7528\u4f4e\u4e8e\u53d1\u5c04\u6ce2\u957f\u7684\u4efb\u610f\u6ce2\u957f\u6fc0\u53d1\u5b83\u4eec\uff0c\u6fc0\u53d1\u6ce2\u957f\u8d8a\u77ed\uff0cQdot\u7eb3\u7c73\u6676\u4f53\u91ca\u653e\u51fa\u7684\u8367\u5149\u8d8a\u5f3a\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6700\u8fd12023\u5e74\u8bfa\u8d1d\u5c14\u5316\u5b66\u5956\u5df2\u7ecf\u63ed\u79d8\uff0c\u8499\u5409\u00b7\u5df4\u6587\u8fea\u3001\u8def\u6613\u65af\u00b7\u5e03\u9c81\u65af\u548c\u963f\u5217\u514b\u8c22\u00b7\u53f6\u57fa\u83ab\u592b\u4e09\u4f4d\u79d1\u5b66\u5bb6\u56e0\u4ed6\u4eec\u5728\u53d1\u73b0\u548c\u5408<\/p>\n","protected":false},"author":1852,"featured_media":1195,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[111],"division":[9],"class_list":["post-1194","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-111","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u91cf\u5b50\u70b9 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u91cf\u5b50\u70b9\" \/>\n<meta property=\"og:description\" content=\"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-25T07:22:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"980\" \/>\n\t<meta property=\"og:image:height\" content=\"978\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u91cf\u5b50\u70b9\",\"datePublished\":\"2026-03-25T07:22:19+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/\"},\"wordCount\":51,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-223211@2x.png\",\"keywords\":[\"\u91cf\u5b50\u70b9\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/\",\"name\":\"\u91cf\u5b50\u70b9 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-223211@2x.png\",\"datePublished\":\"2026-03-25T07:22:19+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-223211@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-223211@2x.png\",\"width\":980,\"height\":978},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/quantum-dots\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u91cf\u5b50\u70b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u91cf\u5b50\u70b9 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/","og_locale":"zh_CN","og_type":"article","og_title":"\u91cf\u5b50\u70b9","og_description":"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-25T07:22:19+00:00","article_modified_time":"2026-04-22T21:59:27+00:00","og_image":[{"width":980,"height":978,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/quantum-dots\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u91cf\u5b50\u70b9","datePublished":"2026-03-25T07:22:19+00:00","dateModified":"2026-04-22T21:59:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/quantum-dots\/"},"wordCount":51,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png","keywords":["\u91cf\u5b50\u70b9"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/quantum-dots\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/","name":"\u91cf\u5b50\u70b9 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png","datePublished":"2026-03-25T07:22:19+00:00","dateModified":"2026-04-22T21:59:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u91cf\u5b50\u70b9\u662f\u4e00\u7c7b\u975e\u5e38\u5c0f\u7684\u7eb3\u7c73\u6676\u4f53\u6750\u6599\uff0c\u5b83\u7531\u4e0d\u540c\u6570\u91cf\u7684\u539f\u5b50\u6784\u6210\uff0c\u91cf\u5b50\u70b9\u5438\u6536\u7535\u5b50\u540e\u4fbf\u4f1a\u53d1\u51fa\u7279\u5b9a\u9891\u7387\u7684\u5149\uff0c\u800c\u53d1\u51fa\u7684\u5149\u9891\u7387\u4f1a\u968f\u7740\u91cf\u5b50\u70b9\u7c92\u5f84\u7684\u6539\u53d8\u800c\u53d8\u5316\uff0c\u56e0\u800c\u901a\u8fc7\u8c03\u8282\u7c92\u5f84\u5927\u5c0f\u5c31\u53ef\u4ee5\u63a7\u5236\u5176\u53d1\u51fa\u7684\u5149\u989c\u8272\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png","width":980,"height":978},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/quantum-dots\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u91cf\u5b50\u70b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":111,"label":"\u91cf\u5b50\u70b9"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-223211@2x.png",760,758,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":111,"name":"\u91cf\u5b50\u70b9","slug":"%e9%87%8f%e5%ad%90%e7%82%b9","term_group":0,"term_taxonomy_id":111,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1194"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1194\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1195"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1194"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}