{"id":1209,"date":"2026-03-25T07:30:14","date_gmt":"2026-03-25T07:30:14","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1209"},"modified":"2026-04-22T21:59:27","modified_gmt":"2026-04-22T21:59:27","slug":"fixable-viability-dye-2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fixable-viability-dye-2\/","title":{"rendered":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Q \u4eb2\u7231\u7684\u540c\u5b66\uff0c\u4f60\u77e5\u9053\u5417\uff1f\u6d41\u5f0fPanel\u4e2d\u8981\u6709\u53bb\u9664\u6b7b\u7ec6\u80de\u7684\u8367\u5149\u67d3\u6599\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5728\u68c0\u6d4b\u7ec6\u80de\u5185\u7ec6\u80de\u56e0\u5b50\u6216\u7ec6\u80de\u6838\u5185\u9776\u6807\u65f6\uff0cPI\u548c7-AAD\u662f\u4e0d\u591f\u7684\uff0c\u8fd9\u8981\u7528\u5230\u53ef\u56fa\u5b9a\u7684\u6d41\u5f0f\u8367\u5149\u67d3\u6599\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e9b\u90fd\u662f\u975e\u5e38\u91cd\u8981\u7684\u77e5\u8bc6\u70b9\u54e6\uff01\u5728\u8fd9\u91cc\uff0c\u4f60\u53ef\u4ee5\u5feb\u901fGet\u5230Dr.\u8d5b\u4e3a\u4f60\u51c6\u5907\u7684\u6d41\u5f0f\u68c0\u6d4b\u7ec6\u80de\u6d3b\u6027\u57fa\u7840\u77e5\u8bc6\uff0c\u8fd8\u6709\u63a8\u8350\u7684\u53ef\u56fa\u5b9a\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u597d\u7269\uff01<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u9274\u5b9a\u7ec6\u80de\u6b7b\u6d3b\"><strong>\u4e3a\u4ec0\u4e48\u9274\u5b9a\u7ec6\u80de\u6b7b\u6d3b\uff1f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6837\u54c1\u4e2d\u7684\u6b7b\u7ec6\u80de\u4f1a\u7531\u4e8e\u81ea\u53d1\u8367\u5149\u4ee5\u53ca\u975e\u7279\u5f02\u6027\u7684\u6297\u4f53\u6216\u8005\u67d3\u6599\u7ed3\u5408\uff0c\u5bfc\u81f4\u5047\u9633\u6027\u5e76\u589e\u52a0\u80cc\u666f\u4fe1\u53f7\uff0c\u56e0\u6b64\u4ece\u6d41\u5f0f\u5b9e\u9a8c\u6570\u636e\u4e2d\u79fb\u9664\u6b7b\u7ec6\u80de\u662f\u786e\u4fdd\u7ed3\u679c\u7cbe\u786e\u7684\u5173\u952e\u6b65\u9aa4\u3002\u6211\u4eec\u4ee5\u6570\u636e\u8bf4\u8bdd\uff0c\u8bf7\u770b\u56fe\u72471\u4e2d\u7684\u4f8b\u5b50\uff0c\u56fe\u4e2d\u6570\u636e\u501f\u52a9\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\u6392\u9664\u4e86\u6b7b\u7ec6\u80de\u7684\u4fe1\u53f7\u5e72\u6270\u540e\uff0c\u5206\u6790\u5f97\u5230\u7684CD8+\u6216\u8005CD19+\u7ec6\u80de\u6bd4\u4f8b\u66f4\u51c6\u786e\u4e86\u3002\u56e0\u6b64\uff0c\u63a8\u8350\u5927\u5bb6\u8fdb\u884c\u6d41\u5f0f\u5b9e\u9a8c\u65f6\uff0c\u5c3d\u91cf\u642d\u914d\u4e0a\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"626\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1-1024x626.png\" alt=\"\" class=\"wp-image-1211\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1-1024x626.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1-300x183.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1-768x469.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1.png 1060w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"659\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224331@2x-1024x659.png\" alt=\"\" class=\"wp-image-1212\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224331@2x-1024x659.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224331@2x-300x193.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224331@2x-768x494.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224331@2x.png 1066w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe 1. \u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\u6392\u9664\u6b7b\u7ec6\u80de\u5e72\u6270\u3002<\/strong>&nbsp;\u901a\u8fc7\u5149\u6563\u5c04\u7684\u95e8\u63a7\u5708\u51fa\u76ee\u6807\u6dcb\u5df4\u7ec6\u80de\uff0c\u5206\u6790\u540e\u7684CD8+\u6216\u8005CD19+\u7ec6\u80de\u6bd4\u4f8b\u660e\u663e\u504f\u9ad8\uff08\u4e0a\u56fe\uff09\uff1b\u76f8\u540c\u6837\u54c1\u501f\u52a9\u6b7b\u6d3b\u67d3\u6599\uff0c\u6392\u9664\u4e86\u6b7b\u7ec6\u80de\u7684\u4fe1\u53f7\u5e72\u6270\u540e\uff0c\u5206\u6790\u540e\u7684CD8+\u6216\u8005CD19+\u7ec6\u80de\u6bd4\u4f8b\u66f4\u51c6\u786e\u4e86\uff08\u4e0b\u56fe\uff09\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5982\u4f55\u9009\u62e9\u5408\u9002\u7684\u6b7b\u6d3b\u67d3\u6599\"><strong>\u5982\u4f55\u9009\u62e9\u5408\u9002\u7684\u6b7b\u6d3b\u67d3\u6599\uff1f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f20\u7edf\u7684\u6d41\u5f0f\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\u4e3a\u7ec6\u80de\u819c\u975e\u901a\u900f\u6027\u7684\u6838\u9178\u67d3\u6599\uff0c\u4f8b\u5982PI\u30017-AAD\u3001DAPI\u3002\u8fd9\u7c7b\u6838\u9178\u67d3\u6599\u80fd\u7a7f\u8fc7\u6b7b\u7ec6\u80de\u7684\u7ec6\u80de\u819c\uff0c\u7ed3\u5408\u6838\u9178\u540e\u53d1\u51fa\u8367\u5149\uff0c\u800c\u65e0\u6cd5\u7a7f\u8fc7\u6d3b\u7ec6\u80de\u7684\u7ec6\u80de\u819c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f46\u662f\uff0c\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u60a8\u53ef\u80fd\u4f1a\u9047\u5230\u56fe2\u4e0a\u56fe\u8fd9\u79cd\u60c5\u51b5\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"876\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224435@2x-1024x876.png\" alt=\"\" class=\"wp-image-1213\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224435@2x-1024x876.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224435@2x-300x257.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224435@2x-768x657.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224435@2x.png 1064w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe 2. \u56fa\u5b9a\u540e LIVE\/DEAD\u2122 Fixable dye\u4fe1\u53f7\u53ef\u4fdd\u7559\u3002<\/strong>\u5206\u522b\u7528PI\u6216LIVE\/DEAD\u2122 Fixable Stain\u6807\u8bb0\u7ec6\u80de\uff0cPI\u6807\u8bb0\u7684\u7ec6\u80de\u56fa\u5b9a\u540e\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\uff08\u4e0a\u56fe\uff09\uff0cLIVE\/DEAD\u2122 Fixable dye\u5728\u56fa\u5b9a\u540e\u7ef4\u6301\u4e86\u6b7b\u7ec6\u80de\u548c\u6d3b\u7ec6\u80de\u7684\u533a\u522b\uff08\u4e0b\u56fe\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fixable viability dye\uff08LIVE\/DEAD\u2122 Fixable dye\uff09\u662f\u4e00\u79cd\u7ec6\u80de\u819c\u975e\u901a\u900f\u6027\u7684\u80fa\u53cd\u5e94\u67d3\u6599\uff0c \u8fd9\u4e9b\u67d3\u6599\u53ea\u80fd\u7a7f\u8fc7\u7ec6\u80de\u819c\u53d7\u635f\u7684\u7ec6\u80de\uff0c\u4e0e\u7ec6\u80de\u8868\u9762\u6216\u8005\u7ec6\u80de\u5185\u7684\u6e38\u79bb\u80fa\u57fa\u5f62\u6210\u5171\u4ef7\u7ed3\u5408\uff08\u89c1\u56fe3\uff09\u3002\u4e14\u7531\u4e8e\u5171\u4ef7\u5076\u8054\u6bd4\u8f83\u7a33\u5b9a\uff0c\u56e0\u6b64\u5bf9\u7ec6\u80de\u67d3\u8272\u540e\u53ef\u4ee5\u517c\u5bb9\u919b\u7c7b\u56fa\u5b9a\u548c\u7834\u819c\u5904\u7406\uff0c\u67d3\u8272\u7ed3\u679c\u4e0d\u53d7\u5f71\u54cd\uff08\u89c1\u56fe2\u4e0b\u56fe\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"356\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224459@2x-1024x356.png\" alt=\"\" class=\"wp-image-1214\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224459@2x-1024x356.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224459@2x-300x104.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224459@2x-768x267.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224459@2x.png 1076w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe3. LIVE\/DEAD \u53ef\u56fa\u5b9a\u6b7b\u7ec6\u80de\u67d3\u8272\u539f\u7406\u3002<\/strong>&nbsp;\u975e\u7ec6\u80de\u901a\u900f\u7684\u80fa\u53cd\u5e94\u67d3\u6599\u4ec5\u80fd\u7ed3\u5408\u5230\u6d3b\u7ec6\u80de\u7684\u8868\u9762\uff0c\u4ea7\u751f\u975e\u5e38\u5fae\u5f31\u7684\u8367\u5149\u3002\u8fd9\u4e9b\u67d3\u6599\u53ef\u7a7f\u900f\u6b7b\u7ec6\u80de\u7684\u7ec6\u80de\u819c\u5e76\u4e0e\u5185\u90e8\u7684\u86cb\u767d\u53d1\u751f\u7ed3\u5408\uff0c\u4ece\u800c\u4ea7\u751f\u6781\u5f3a\u7684\u8367\u5149\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e0b\u8868\u662f\u4e24\u79cd\u67d3\u6599\u7684\u9009\u62e9\u6307\u5357\"><strong>\u4e0b\u8868\u662f\u4e24\u79cd\u67d3\u6599\u7684\u9009\u62e9\u6307\u5357<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"665\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224532@2x-1024x665.png\" alt=\"\" class=\"wp-image-1215\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224532@2x-1024x665.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224532@2x-300x195.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224532@2x-768x499.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224532@2x.png 1066w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-question-amp-answer\"><strong>Question &amp; Answer<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u4f7f\u7528Fixable viability dye\u65f6\uff0c\u67d3\u8272\u6db2\u6709\u4ec0\u4e48\u8981\u6c42\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u5f53\u4f7f\u7528\u53ef\u56fa\u5b9a\u7684\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u65f6\uff0cTris\u7f13\u51b2\u6db2\u548c\u542b\u6709\u53e0\u6c2e\u5316\u94a0\u6216\u5916\u6765\u86cb\u767d\u8d28\u7684\u6eb6\u6db2\u4e0d\u80fd\u4f5c\u4e3a\u7ec6\u80de\u67d3\u8272\u7f13\u51b2\u6db2\uff0c\u56e0\u4e3a\u6eb6\u6db2\u4e2d\u542b\u6709\u8fd9\u4e9b\u7269\u8d28\u53ef\u80fd\u5bfc\u81f4\u6b7b\u7ec6\u80de\u7fa4\u67d3\u8272\u5f3a\u5ea6\u7684\u663e\u8457\u964d\u4f4e\u548c\/\u6216\u6d3b\u7ec6\u80de\u7fa4\u80cc\u666f\u67d3\u8272\u7684\u589e\u52a0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q \u6d41\u5f0f\u5b9e\u9a8c\u4e2d\uff0c\u5229\u7528LIVE\/DEAD Fixable dead cell stain\u6216\u8005\u662fFixable Viability Dye \u80fa\u57fa\u53cd\u5e94\u67d3\u6599\u9274\u5b9a\u6b7b\u6d3b\u7ec6\u80de\uff0c\u9700\u5982\u4f55\u5236\u5907\u8865\u507f\u5355\u67d3\u7ba1\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u8865\u507f\u6837\u672c\u4e2d\u9700\u8981\u540c\u65f6\u68c0\u6d4b\u5230\u9633\u6027\u4fe1\u53f7\u548c\u9634\u6027\u4fe1\u53f7\uff0c\u6211\u4eec\u63d0\u4f9b\u4e24\u79cd\u65b9\u6848\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u51c6\u5907\u6d3b\u7ec6\u80de\u4e0e\u6b7b\u7ec6\u80de\u7684\u6df7\u5408\u6837\u672c\uff1a\u5c06\u4e00\u4efd\u6d3b\u7ec6\u80de\u6837\u672c\u5e73\u5747\u5206\u6210\u4e24\u4efd\uff0c\u4e00\u4efd\u4e0d\u505a\u5904\u7406\uff0c\u4e00\u4efd\u5236\u5907\u6210\u6b7b\u7ec6\u80de\uff0c\u5236\u5907\u5b8c\u6210\u540e\u5c06\u4e24\u4efd\u6837\u672c\u91cd\u65b0\u6df7\u5408\uff0c\u518d\u8fdb\u884c\u67d3\u8272\u3002\u5236\u5907\u6b7b\u7ec6\u80de\u7684\u65b9\u6cd5\u8bf7\u53c2\u8003\u5982\u4e0b\u63cf\u8ff0\uff1a\u53ef\u4ee5\u901a\u8fc760\u00b0C\u653e\u7f6e20\u5206\u949f\u70ed\u706d\u6d3b\u7ec6\u80de\u3002\u6216\u5c06\u7ec6\u80de\u653e\u516570%\u4e59\u9187\u56fa\u5b9a\uff0c\u4e59\u9187\u56fa\u5b9a\u7684\u7ec6\u80de\u53ef\u4ee5\u4fdd\u5b58\u5728-20\u00b0C\uff0c\u4f7f\u7528\u524d\u518d\u53d6\u51fa\u3002<\/li>\n\n\n\n<li>\u5229\u7528ArC\u2122 \u80fa\u53cd\u5e94\u8865\u507f\u73e0\u8bd5\u5242\u76d2\uff08\u8d27\u53f7A10346\uff09\uff0c\u8be5\u4ea7\u54c1\u53ef\u4e0e\u5177\u6709\u80fa\u53cd\u5e94\u6027\u7684LIVE\/DEAD Fixable dead cell stain\u6216\u8005\u662fFixable Viability Dye\u53ef\u56fa\u5b9a\u6b7b\u7ec6\u80de\u67d3\u6599\u7ed3\u5408\uff0c\u4ee5\u7528\u4e8e\u6d41\u5f0f\u8865\u507f\u8c03\u8282\uff0c\u800c\u65e0\u9700\u81ea\u5df1\u5236\u5907\u8865\u507f\u6837\u672c\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q Fixable Viability Dye\u6d41\u5f0f\u67d3\u8272\u7ed3\u679c\u5982\u4f55\u89e3\u8bfb\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A <\/strong>\u76f8\u5bf9\u4e8e\u672a\u67d3\u8272\u7684\u7ec6\u80de\uff0cFixable Viability Dye\u67d3\u8272\u7684\u7ec6\u80de\u6574\u4f53\u90fd\u4f1a\u68c0\u6d4b\u5230\u8367\u5149\u4fe1\u53f7\uff0c\u4f46\u662f\u53ef\u4ee5\u901a\u8fc7\u4fe1\u53f7\u7684\u5f3a\u5f31\u6765\u533a\u5206\u6d3b\u7ec6\u80de\u548c\u6b7b\u7ec6\u80de\u3002\u5176\u4e2d\u6d3b\u7ec6\u80de\u7684\u7ec6\u80de\u819c\u5b8c\u6574\uff0c\u4ec5\u7ec6\u80de\u8868\u9762\u86cb\u767d\u80fa\u57fa\u7ed3\u5408\u4e86\u67d3\u6599\uff0c\u5448\u73b0\u8f83\u5f31\u7684\u8367\u5149\u4fe1\u53f7\uff1b\u800c\u6b7b\u7ec6\u80de\u7684\u7ec6\u80de\u819c\u901a\u900f\u6027\u6539\u53d8\uff0c\u67d3\u6599\u80fd\u591f\u8fdb\u5165\u6b7b\u7ec6\u80de\uff0c\u4e0e\u7ec6\u80de\u5185\u548c\u7ec6\u80de\u8868\u9762\u86cb\u767d\u4e0a\u7684\u80fa\u57fa\u7ed3\u5408\uff0c\u56e0\u6b64\u6b7b\u7ec6\u80de\u5448\u73b0\u66f4\u5f3a\u7684\u8367\u5149\u4fe1\u53f7\u3002\uff08\u89c1\u56fe4\uff09<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"786\" height=\"758\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224645@2x.png\" alt=\"\" class=\"wp-image-1216\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224645@2x.png 786w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224645@2x-300x289.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224645@2x-768x741.png 768w\" sizes=\"auto, (max-width: 786px) 100vw, 786px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe4. Fixable Viability Dye\u6d41\u5f0f\u67d3\u8272\u7ed3\u679c\u89e3\u8bfb\u3002\u5c06\u672a\u67d3\u8272\u7ec6\u80de\u548cFixable Viability Dye\u67d3\u8272\u7ec6\u80de\u6d41\u5f0f\u5206\u6790\u7ed3\u679c\u5408\u5e76\u5206\u6790\u3002\u76f8\u5bf9\u4e8e\u672a\u67d3\u8272\u7684\u7ec6\u80de\uff0cFixable Viability Dye\u67d3\u8272\u7684\u7ec6\u80de\u6574\u4f53\u90fd\u4f1a\u68c0\u6d4b\u5230\u8367\u5149\u4fe1\u53f7\uff0c\u5176\u4e2d\u6b7b\u7ec6\u80de\u5448\u73b0\u6bd4\u8f83\u5f3a\u7684\u8367\u5149\u4fe1\u53f7\uff0c\u800c\u6d3b\u7ec6\u80de\u5448\u73b0\u7684\u4fe1\u53f7\u8f83\u5f31\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q \u6211\u53ef\u4ee5\u5c06\u6d41\u5f0fFixable Viability Dye\u67d3\u8272\u7684\u7ec6\u80de\u901a\u8fc7\u8367\u5149\u663e\u5fae\u955c\u89c2\u5bdf\u7ec6\u80de\u6b7b\u6d3b\u5417\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A \u4e0d\u5efa\u8bae\uff0c\u8be5\u67d3\u6599\u5bf9\u57fa\u4e8e\u6210\u50cf\u7684\u5b9e\u9a8c\u6548\u679c\u4e0d\u597d\uff0c\u7531\u4e8e\u6240\u6709\u7ec6\u80de\u90fd\u88ab\u67d3\u8272\uff0c\u5f88\u96be\u901a\u8fc7\u663e\u5fae\u955c\u4ece\u6697\u6de1\u7684\u6d3b\u7ec6\u80de\u4e2d\u5206\u8fa8\u51fa\u660e\u4eae\u7684\u6b7b\u7ec6\u80de\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Q \u4eb2\u7231\u7684\u540c\u5b66\uff0c\u4f60\u77e5\u9053\u5417\uff1f\u6d41\u5f0fPanel\u4e2d\u8981\u6709\u53bb\u9664\u6b7b\u7ec6\u80de\u7684\u8367\u5149\u67d3\u6599\u3002 A \u5728\u68c0\u6d4b\u7ec6\u80de\u5185\u7ec6\u80de\u56e0\u5b50\u6216\u7ec6\u80de\u6838\u5185\u9776\u6807\u65f6<\/p>\n","protected":false},"author":1852,"featured_media":1210,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[90],"division":[9],"class_list":["post-1209","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-90","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599\" \/>\n<meta property=\"og:description\" content=\"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-25T07:30:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1060\" \/>\n\t<meta property=\"og:image:height\" content=\"648\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye-2\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599\",\"datePublished\":\"2026-03-25T07:30:14+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye-2\\\/\"},\"wordCount\":100,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-224324@2x.png\",\"keywords\":[\"\u6d41\u5f0f\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye-2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/\",\"name\":\"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-224324@2x.png\",\"datePublished\":\"2026-03-25T07:30:14+00:00\",\"dateModified\":\"2026-04-22T21:59:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-224324@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260319-224324@2x.png\",\"width\":1060,\"height\":648},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/fixable-viability-dye\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/","og_locale":"zh_CN","og_type":"article","og_title":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599","og_description":"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-25T07:30:14+00:00","article_modified_time":"2026-04-22T21:59:27+00:00","og_image":[{"width":1060,"height":648,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fixable-viability-dye-2\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599","datePublished":"2026-03-25T07:30:14+00:00","dateModified":"2026-04-22T21:59:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fixable-viability-dye-2\/"},"wordCount":100,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png","keywords":["\u6d41\u5f0f"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/fixable-viability-dye-2\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/","name":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png","datePublished":"2026-03-25T07:30:14+00:00","dateModified":"2026-04-22T21:59:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u5982\u679c\u5b9e\u9a8c\u6d89\u53ca\u5230\u80de\u5185\u67d3\u8272\uff0c\u7ec6\u80de\u9700\u8981\u56fa\u5b9a\u7834\u819c\uff0c\u6838\u9178\u67d3\u6599\u4f1a\u5c06\u6240\u6709\u7684\u7ec6\u80de\u90fd\u67d3\u4e0a\u989c\u8272\uff0c\u96be\u4ee5\u5206\u8fa8\u6b7b\u6d3b\u4fe1\u53f7\u3002\u6b64\u65f6\u60a8\u5e94\u8be5\u9009\u62e9\u53ef\u4ee5\u56fa\u5b9a\u7684\u7ec6\u80de\u6b7b\u6d3b\u67d3\u6599\uff0c\u5373Fixable viability dye\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x.png","width":1060,"height":648},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/fixable-viability-dye\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u6d41\u5f0f\u53ef\u56fa\u5b9a\u6d3b\u6027\u67d3\u6599"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":90,"label":"\u6d41\u5f0f"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260319-224324@2x-1024x626.png",760,465,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":90,"name":"\u6d41\u5f0f","slug":"%e6%b5%81%e5%bc%8f","term_group":0,"term_taxonomy_id":90,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1209"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1209\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1210"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1209"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1209"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1209"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}