{"id":1237,"date":"2026-03-26T02:43:01","date_gmt":"2026-03-26T02:43:01","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1237"},"modified":"2026-04-22T21:59:26","modified_gmt":"2026-04-22T21:59:26","slug":"guide-to-selecting-immunofluorescence-methods","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/","title":{"rendered":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5728\u751f\u547d\u79d1\u5b66\u7814\u7a76\u4e2d\uff0c\u514d\u75ab\u8367\u5149\uff08Immunofluorescence, IF\uff09\u662f\u6700\u5e38\u7528\u7684\u6210\u50cf\u624b\u6bb5\u4e4b\u4e00\u3002\u5b83\u80fd\u5e2e\u52a9\u79d1\u7814\u4eba\u5458\u5728\u7ec6\u80de\u4e0e\u7ec4\u7ec7\u4e2d\u201c\u770b\u5230\u201d\u86cb\u767d\u8d28\u7684\u7a7a\u95f4\u5206\u5e03\u3001\u8868\u8fbe\u53d8\u5316\u3001\u4fe1\u53f7\u901a\u8def\u4fe1\u606f\uff0c\u751a\u81f3\u662f\u75be\u75c5\u5fae\u73af\u5883\u4e2d\u7684\u590d\u6742\u7ec6\u80de\u5173\u7cfb\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7136\u800c\uff0c\u968f\u7740\u6280\u672f\u7684\u53d1\u5c55\uff0c<strong>\u514d\u75ab\u8367\u5149\u7684\u9009\u62e9\u5df2\u7ecf\u4e0d\u518d\u662f\u7b80\u5355\u7684\u201c\u7528\u4ec0\u4e48\u989c\u8272\u201d\u8fd9\u4e48\u5bb9\u6613\u3002<\/strong>\u9762\u5bf9<strong>\u9ad8\u4f4e\u4e0d\u540c\u7684\u9776\u6807\u4e30\u5ea6<\/strong>\u3001\u4e0d\u65ad\u589e\u957f\u7684<strong>\u591a\u91cd\u68c0\u6d4b<\/strong>\u9700\u6c42\u3001\u5404\u5f0f\u5404\u6837\u7684\u4fe1\u53f7\u653e\u5927\u65b9\u5f0f\u4e0e\u6210\u50cf\u5e73\u53f0\uff0c\u5982\u4f55\u9009\u62e9\u6700\u5408\u9002\u7684\u514d\u75ab\u8367\u5149\u7b56\u7565\uff0c\u6210\u4e3a\u8bb8\u591a\u79d1\u7814\u4eba\u5458\u7684\u5171\u540c\u56f0\u60d1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u5929\uff0c\u8fd9\u7bc7\u63a8\u6587\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684<strong>\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357<\/strong>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u514d\u75ab\u8367\u5149\u7684\u5e38\u89c1\u5e94\u7528\u573a\u666f\"><strong>\u514d\u75ab\u8367\u5149\u7684\u5e38\u89c1\u5e94\u7528\u573a\u666f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u514d\u75ab\u8367\u5149\u51e0\u4e4e\u51fa\u73b0\u5728\u6240\u6709\u4e0e\u7ec6\u80de\u3001\u7ec4\u7ec7\u76f8\u5173\u7684\u7814\u7a76\u9886\u57df\uff0c\u5305\u62ec\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7ec6\u80de\u751f\u7269\u5b66\u7814\u7a76\uff1a\u63a2\u7a76\u86cb\u767d\u5b9a\u4f4d\u4e0e\u52a8\u6001\u53d8\u5316<\/strong><br>\u4f8b\u5982\u89c2\u5bdf\u7ec6\u80de\u9aa8\u67b6\u3001\u8f6c\u5f55\u56e0\u5b50\u5b9a\u4f4d\u3001\u7ec6\u80de\u5468\u671f\u86cb\u767d\u7b49\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u80bf\u7624\u5fae\u73af\u5883\u89e3\u6790<\/strong><br>\u591a\u91cd\u514d\u75ab\u8367\u5149\u80fd\u540c\u65f6\u8bc6\u522b\u514d\u75ab\u7ec6\u80de\u4e9a\u7fa4\u3001\u80bf\u7624\u6807\u5fd7\u7269\u3001\u6210\u7ea4\u7ef4\u7ec6\u80de\u3001\u8840\u7ba1\u751f\u6210\u7b49\u5173\u952e\u7279\u5f81\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u795e\u7ecf\u79d1\u5b66\u7814<\/strong><br>\u7528\u4e8e\u8bc6\u522b\u795e\u7ecf\u5143\u4e9a\u578b\u3001\u795e\u7ecf\u80f6\u8d28\u7ec6\u80de\u3001\u7a81\u89e6\u6807\u5fd7\u7269\u53ca\u75c5\u7406\u6c89\u79ef\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7ec4\u7ec7\u5b66\u4e0e\u75c5\u7406\u7814\u7a76<\/strong><br>\u5e2e\u52a9\u75c5\u7406\u7814\u7a76\u8005\u89c2\u5bdf\u7ec6\u80de\u5171\u8868\u8fbe\u3001\u533a\u57df\u7279\u5f02\u6027\u53d8\u5316\u3001\u75be\u75c5\u6a21\u578b\u4e2d\u7684\u7ec4\u7ec7\u7ed3\u6784\u53d8\u5316\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u836f\u6548 &amp; \u6bd2\u7406\u5b66\u8bc4\u4f30<\/strong><br>\u5b9a\u4f4d\u836f\u7269\u9776\u70b9\u3001\u68c0\u6d4b\u751f\u7269\u6807\u5fd7\u7269\u53d8\u5316\uff0c\u662f\u65b0\u836f\u7814\u53d1\u7684\u91cd\u8981\u624b\u6bb5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u514d\u75ab\u8367\u5149\u7684\u4ef7\u503c\u5728\u4e8e\uff1a<strong>\u4e0d\u4ec5\u770b\u201c\u6709\u6ca1\u6709\u201d\uff0c\u8fd8\u80fd\u770b\u201c\u5728\u54ea\u91cc\u201d\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u514d\u75ab\u8367\u5149\u7684\u524d\u6cbf\u6280\u672f-\u4ece\u4f20\u7edf\u4e09\u8272\u5230\u9ad8\u7ef4\u7a7a\u95f4\u89e3\u6790\"><strong>\u514d\u75ab\u8367\u5149\u7684\u524d\u6cbf\u6280\u672f\uff1a\u4ece\u4f20\u7edf\u4e09\u8272\u5230\u9ad8\u7ef4\u7a7a\u95f4\u89e3\u6790<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u968f\u7740\u7a7a\u95f4\u7ec4\u5b66\u7684\u5174\u8d77\uff0c\u514d\u75ab\u8367\u5149\u65e9\u5df2\u4ece\u4f20\u7edf\u7684 3\u20134 \u8272\u6210\u50cf\u53d1\u5c55\u4e3a\u80fd\u4e00\u6b21\u6027\u83b7\u53d6\u5927\u91cf\u4fe1\u606f\u7684\u524d\u6cbf\u6280\u672f\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5149\u8c31\u6210\u50cf + \u5149\u8c31\u62c6\u5206<\/strong><br>\u53ef\u5c06 8\u201310 \u79cd\u5149\u8c31\u91cd\u53e0\u7684\u67d3\u6599\u533a\u5206\u5f00\uff0c\u5b9e\u73b0<strong>\u5355\u6b21\u626b\u63cf\u591a\u91cd\u6210\u50cf<\/strong>\uff0c\u5e38\u7528\u4e8e\u4e2d\u901a\u91cf\u7a7a\u95f4\u7ec4\u5b66\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u916a\u80fa\u4fe1\u53f7\u653e\u5927<\/strong><br>\u9002\u7528\u4e8e\u4f4e\u4e30\u5ea6\u9776\u6807\uff0c\u80fd\u663e\u8457\u63d0\u5347\u4fe1\u566a\u6bd4\uff0c\u5c24\u5176\u9002\u5408 FFPE \u7ec4\u7ec7\u548c\u5f31\u8868\u8fbe\u86cb\u767d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5faa\u73af\u514d\u75ab\u8367\u5149<\/strong><br>\u901a\u8fc7\u201c\u67d3\u8272\u2014\u6210\u50cf\u2014\u5265\u79bb\u2014\u518d\u67d3\u8272\u201d\uff0c\u53ef\u68c0\u6d4b 20\u201360+ \u6807\u8bb0\u7269\uff0c\u662f\u9ad8\u901a\u91cf\u7a7a\u95f4\u7ec4\u5b66\u7684\u91cd\u8981\u624b\u6bb5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>DNA \u6761\u5f62\u7801\u6280\u672f<\/strong><br>\u5927\u5e45\u6269\u5c55\u68c0\u6d4b\u7ef4\u5ea6\uff0c\u662f\u672a\u6765\u9ad8\u901a\u91cf\u7a7a\u95f4\u86cb\u767d\u7ec4\u5b66\u7684\u6838\u5fc3\u5de5\u5177\u4e4b\u4e00\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e9b\u524d\u6cbf\u6280\u672f\u7684\u5171\u540c\u76ee\u6807\u662f\uff1a<br><strong>\u7528\u66f4\u5c11\u7684\u7ec4\u7ec7\uff0c\u5f97\u5230\u66f4\u6df1\u7684\u751f\u7269\u5b66\u4fe1\u606f\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u7684\u5173\u952e\u8003\u91cf\u56e0\u7d20\"><strong>\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u7684\u5173\u952e\u8003\u91cf\u56e0\u7d20<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u9009\u62e9\u514d\u75ab\u8367\u5149\u7b56\u7565\u65f6\uff0c\u53ef\u4ee5\u4ece\u4ee5\u4e0b 10 \u5927\u6838\u5fc3\u56e0\u7d20\u51fa\u53d1\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1.\u9776\u6807\u4e30\u5ea6\uff1a\u51b3\u5b9a\u662f\u5426\u9700\u8981\u653e\u5927<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u4e30\u5ea6\uff1a\u76f4\u63a5\u6297\u4f53\u5373\u53ef<\/li>\n\n\n\n<li>\u4e2d\u4e30\u5ea6\uff1a\u4e8c\u6297\u653e\u5927\u6216\u9ad8\u4eae\u5ea6\u8367\u5149\u67d3\u6599<\/li>\n\n\n\n<li>\u4f4e\u4e30\u5ea6\uff1a\u9176\u4fc3\u653e\u5927\u6548\u679c\u6700\u4f73\uff08\u5982\u916a\u80fa\u4fe1\u53f7\u653e\u5927\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2.\u591a\u91cd\u68c0\u6d4b\u9700\u6c42<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>3\u20134 \u8272 \u2192 \u5e38\u89c4 IF<\/li>\n\n\n\n<li>5\u201310 \u8272 \u2192 \u5149\u8c31\u6210\u50cf<\/li>\n\n\n\n<li>10\u201360 \u8272 \u2192 \u5faa\u73af\u6210\u50cf \/ DNA \u6761\u5f62\u7801<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3.\u4fe1\u566a\u6bd4\u662f\u5426\u591f\u9ad8\uff1f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u80cc\u666f\u9ad8 \u2192 \u539f\u56e0\uff1a\u4fe1\u53f7\u653e\u5927\u65b9\u6cd5\u4e0d\u5f53\u6216\u5149\u8c31\u62c6\u5206\u95ee\u9898<\/li>\n\n\n\n<li>\u81ea\u53d1\u8367\u5149\u5f3a\u7684\u7ec4\u7ec7\u66f4\u9700\u8981\u4f18\u5316<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4.\u662f\u5426\u6709\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u6297\u4f53\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9009\u62e9\u76f4\u63a5\u6807\u8bb0\u3001\u4e8c\u6297\u653e\u5927\u6216DIY\u76f4\u6807\u6297\u4f53\u9700\u6839\u636e\u662f\u5426\u6709\u53ef\u7528\u6297\u4f53\u548c\u6297\u4f53\u7684\u5e94\u7528\u9a8c\u8bc1\u6570\u636e\u51b3\u5b9a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5.\u7ec4\u7ec7\u7c7b\u578b\u4e0e\u6837\u54c1\u8d28\u91cf<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">FFPE \u81ea\u53d1\u8367\u5149\u9ad8\u3001\u539a\u7ec4\u7ec7\u5149\u6563\u5c04\u5f3a\u3001\u77ff\u5316\u7ec4\u7ec7\u96be\u5904\u7406 \u2192 \u4fe1\u53f7\u653e\u5927\u65b9\u6cd5\u9700\u6700\u5927\u5316\u4fe1\u566a\u6bd4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>6.\u6210\u50cf\u5e73\u53f0\u80fd\u529b<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u662f\u5426\u652f\u6301\u5149\u8c31\u6210\u50cf\uff1f<\/li>\n\n\n\n<li>\u76f8\u673a\u7075\u654f\u5ea6\u5982\u4f55\uff1f<\/li>\n\n\n\n<li>\u80fd\u5426\u8fdb\u884c\u5faa\u73af\u6210\u50cf\uff1f<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>7.\u5b9e\u9a8c\u6d41\u7a0b\u590d\u6742\u5ea6\u4e0e\u901a\u91cf<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u60f3\u5feb\uff1f\u2192 \u76f4\u63a5 IF<\/li>\n\n\n\n<li>\u8981\u5e73\u8861\u4eae\u5ea6\uff1f\u2192 \u5149\u8c31\u6210\u50cf<\/li>\n\n\n\n<li>\u8981\u6700\u4e30\u5bcc\u4fe1\u606f\uff1f\u2192 \u5faa\u73af IF<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>8.\u6297\u4f53\u4ea4\u53c9\u53cd\u5e94\u4e0epanel\u8bbe\u8ba1<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7269\u79cd\u9009\u62e9\u3001\u8367\u5149\u67d3\u6599\u642d\u914d\u3001\u5265\u79bb\u517c\u5bb9\u6027\u7b49\u5747\u5f71\u54cd\u5b9e\u9a8c\u6210\u529f\u7387\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>9.\u662f\u5426\u9700\u8981\u5b9a\u91cf\u5206\u6790\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u76f4\u63a5 IF \u6700\u9002\u5408\u5b9a\u91cf\uff0c\u9176\u4fc3\u653e\u5927\u9002\u5408\u68c0\u6d4b\u5f31\u4fe1\u53f7\u4f46\u4e0d\u9002\u5408\u86cb\u767d\/\u9776\u6807\u5b9a\u91cf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>10.\u7ec4\u7ec7\u5b8c\u6574\u6027\u662f\u5426\u5173\u952e\uff1f<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5faa\u73af\u5265\u79bb\u53ef\u80fd\u635f\u4f24\u8868\u4f4d\uff1b\u73cd\u8d35\u7ec4\u7ec7\u9700\u9009\u62e9\u6e29\u548c\u5904\u7406\u65b9\u6cd5\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5982\u4f55\u5feb\u901f\u9009\u62e9\u65b9\u6cd5\"><strong>\u5982\u4f55\u5feb\u901f\u9009\u62e9\u65b9\u6cd5\uff1f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc49 \u82e5\u9776\u6807\u5f31 \u2192 \u4f18\u5148\u9176\u4fc3\u653e\u5927\uff08Aluora\u2122\/TSA\uff09<br>\ud83d\udc49 \u82e5\u901a\u9053\u591a \u2192 \u7528\u5149\u8c31\u6210\u50cf\u6216\u5faa\u73af IF<br>\ud83d\udc49 \u82e5\u7ed3\u6784\u8106\u5f31 \u2192 \u907f\u514d\u591a\u8f6e\u5265\u79bb<br>\ud83d\udc49 \u82e5\u6837\u672c\u73cd\u8d35 \u2192 \u9009\u62e9\u5355\u6b21\u6210\u50cf\u65b9\u6848<br>\ud83d\udc49 \u82e5\u8981\u5b9a\u91cf \u2192 \u907f\u514d\u975e\u7ebf\u6027\u4fe1\u53f7\u653e\u5927\u65b9\u6cd5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5212\u91cd\u70b9-\u9009\u62e9\u514d\u75ab\u8367\u5149\u65b9\u6cd5-\u5c31\u662f\u5e73\u8861\u827a\u672f\"><strong>\u5212\u91cd\u70b9\uff1a\u9009\u62e9\u514d\u75ab\u8367\u5149\u65b9\u6cd5\uff0c\u5c31\u662f\u5e73\u8861\u827a\u672f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u514d\u75ab\u8367\u5149\u6280\u672f\u6b63\u5728\u4ece\u4f20\u7edf\u89c2\u5bdf\u5de5\u5177\uff0c\u5feb\u901f\u8fc8\u5411\u7a7a\u95f4\u751f\u7269\u5b66\u7684\u6838\u5fc3\u5e73\u53f0\u3002\u9009\u62e9\u65b9\u6cd5\u4e0d\u518d\u662f\u4e00\u4e2a\u201c\u8bd5\u8bd5\u770b\u201d\u7684\u8fc7\u7a0b\uff0c\u800c\u662f\u4e00\u9879<strong>\u7efc\u5408\u9776\u6807\u7279\u6027\u3001\u7ec4\u7ec7\u6761\u4ef6\u3001\u5e73\u53f0\u80fd\u529b\u3001\u7814\u7a76\u76ee\u6807<\/strong>\u7684\u4e13\u4e1a\u5224\u65ad\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u5957\u5408\u7406\u7684\u514d\u75ab\u8367\u5149\u7b56\u7565\uff0c\u5c06\u663e\u8457\u63d0\u5347\u6210\u50cf\u8d28\u91cf\u3001\u6570\u636e\u53ef\u4fe1\u5ea6\uff0c\u5e76\u5e2e\u52a9\u7814\u7a76\u4eba\u5458\u5728\u6709\u9650\u7684\u6837\u672c\u4e2d\u6d1e\u5bdf\u66f4\u591a\u751f\u7269\u5b66\u7ebf\u7d22\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u4f60\u6b63\u5728\u89c4\u5212\u590d\u6742panel\u3001\u4f4e\u8868\u8fbe\u9776\u6807\u68c0\u6d4b\u6216\u7a7a\u95f4\u751f\u7269\u5b66\u5206\u6790\uff0c\u53ef\u4ee5\u53c2\u8003\u672c\u6587\u4ece<strong>\u9776\u6807\u4e30\u5ea6 + \u591a\u91cd\u9700\u6c42 + \u80cc\u666f\u6761\u4ef6<\/strong>\u4e09\u4e2a\u7ef4\u5ea6\u5165\u624b\uff0c\u6784\u5efa\u6700\u9002\u5408\u4f60\u7684\u514d\u75ab\u8367\u5149\u65b9\u6848\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u4e00\u89c8\"><strong>\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u4e00\u89c8<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1001\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1-1024x1001.png\" alt=\"\" class=\"wp-image-1240\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1-1024x1001.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1-300x293.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1-768x751.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1.png 1092w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Invitrogen EVOS S1000\u7a7a\u95f4\u751f\u7269\u5b66\u6210\u50cf\u5206\u6790\u7cfb\u7edf<\/strong>\u662f\u8d5b\u9ed8\u98de\u5168\u65b0\u63a8\u51fa\u7684\u4e00\u6b3e\u9ad8\u901f\u5bbd\u573a\u5149\u8c31\u6210\u50cf\u7cfb\u7edf\uff0c\u6574\u5408\u4e86\u591a\u91cd\u5149\u8c31\u8367\u5149\u3001\u900f\u5c04\u660e\u573a\u3001\u76f8\u5dee\u53ca\u5f69\u8272\u660e\u573a\u7b49\u8bf8\u591a\u6210\u50cf\u529f\u80fd\uff0c\u53ef\u5feb\u901f\u5b8c\u6210\u539f\u4f4d\u3001\u591a\u6837\u672c\u3001\u591a\u901a\u9053\u7a7a\u95f4\u7ec4\u5b66\u7814\u7a76\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6280\u672f\u4f18\u52bf\"><strong>\u6280\u672f\u4f18\u52bf<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5feb\u901f\uff1a<\/strong>20\u5206\u949f\u5373\u53ef\u5b8c\u62101cm\u00b2\u7ec4\u7ec7\u76849\u6807\u6210\u50cf\uff0810x\uff1b\u626b\u63cf\u3001\u5149\u8c31\u89e3\u6790\u53ca\u62fc\u63a5\uff09\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7075\u6d3b\uff1a<\/strong>\u517c\u5bb9\u591a\u79cd\u8367\u5149\u67d3\u6599\u3001\u6297\u4f53\u3001RNA\u63a2\u9488\u53ca\u663e\u8272\u8bd5\u5242\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5168\u9762\uff1a<\/strong>\u652f\u6301\u5149\u8c31\u8367\u5149\u3001\u900f\u5c04\u660e\u573a\u3001\u76f8\u5dee\u53ca\u5f69\u8272\u660e\u573a\u6210\u50cf\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9ad8\u7075\u654f\u5ea6\uff1a<\/strong>\u914d\u5907420\u4e07\u50cf\u7d2016-bit\u79d1\u7814\u7ea7sCMOS\u76f8\u673a\uff0c\u53ef\u6e05\u6670\u68c0\u6d4b\u7ec4\u7ec7\u5185\u590d\u6742\u7684\u591a\u91cd\u67d3\u8272\u4fe1\u53f7\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u53ef\u53d8\u500d\u7387\uff1a<\/strong>\u652f\u63012.5x\u201340x\u7269\u955c\uff085\u5b54\u7269\u955c\u8f6c\u76d8\uff09\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9ad8\u6548\uff1a<\/strong>\u81ea\u52a8\u5316\u6fc0\u5149\u805a\u7126\u4e0e\u8f6f\u4ef6\u8f85\u52a9\u805a\u7126\u6d41\u7a0b\u52a0\u901f\u56fe\u50cf\u91c7\u96c6\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6613\u7528\uff1a<\/strong>\u76f4\u89c2\u7684\u8f6f\u4ef6\u754c\u9762\uff0c\u9002\u7528\u4e8e\u4e0d\u540c\u7ecf\u9a8c\u6c34\u5e73\u7684\u7528\u6237\uff08\u56fe\u50cf\u91c7\u96c6\u3001\u5bfc\u822a\u53ca\u6570\u636e\u68c0\u7d22\uff09\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u517c\u5bb9\u6027\uff1a<\/strong>\u652f\u6301TIFF\u3001OME-TIFF\u53ca\u5206\u5c42\u56fe\u50cf\u683c\u5f0f\uff0c\u9002\u914d\u5404\u7c7b\u6570\u636e\u5206\u6790\u8f6f\u4ef6\uff1b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9ad8\u5206\u8fa8\u7387\uff1a<\/strong>\u5149\u8c31\u89e3\u6790\u6280\u672f\u51cf\u5c11\u8367\u5149\u4e32\u8272\uff0c\u751f\u6210\u9ad8\u5206\u8fa8\u7387\u56fe\u50cf\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5728\u751f\u547d\u79d1\u5b66\u7814\u7a76\u4e2d\uff0c\u514d\u75ab\u8367\u5149\uff08Immunofluorescence, IF\uff09\u662f\u6700\u5e38\u7528\u7684\u6210\u50cf\u624b\u6bb5\u4e4b\u4e00\u3002\u5b83\u80fd\u5e2e\u52a9\u79d1\u7814<\/p>\n","protected":false},"author":1852,"featured_media":1239,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[116],"division":[9],"class_list":["post-1237","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-116","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01\" \/>\n<meta property=\"og:description\" content=\"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-26T02:43:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:26+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1092\" \/>\n\t<meta property=\"og:image:height\" content=\"1068\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01\",\"datePublished\":\"2026-03-26T02:43:01+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/\"},\"wordCount\":29,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180134@2x.png\",\"keywords\":[\"\u514d\u75ab\u8367\u5149\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/\",\"name\":\"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180134@2x.png\",\"datePublished\":\"2026-03-26T02:43:01+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180134@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180134@2x.png\",\"width\":1092,\"height\":1068},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/guide-to-selecting-immunofluorescence-methods\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/","og_locale":"zh_CN","og_type":"article","og_title":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01","og_description":"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-26T02:43:01+00:00","article_modified_time":"2026-04-22T21:59:26+00:00","og_image":[{"width":1092,"height":1068,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01","datePublished":"2026-03-26T02:43:01+00:00","dateModified":"2026-04-22T21:59:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/"},"wordCount":29,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png","keywords":["\u514d\u75ab\u8367\u5149"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/","name":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png","datePublished":"2026-03-26T02:43:01+00:00","dateModified":"2026-04-22T21:59:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u8fd9\u7bc7\u6587\u7ae0\u5c06\u5e26\u4f60\u4ece\u5e94\u7528\u573a\u666f\u5230\u524d\u6cbf\u6280\u672f\uff0c\u518d\u5230\u65b9\u6cd5\u9009\u62e9\u7684\u6838\u5fc3\u56e0\u7d20\uff0c\u6784\u5efa\u4e00\u5957\u6e05\u6670\u3001\u5b9e\u7528\u7684\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x.png","width":1092,"height":1068},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/guide-to-selecting-immunofluorescence-methods\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u514d\u75ab\u8367\u5149\u65b9\u6cd5\u9009\u62e9\u6307\u5357\uff1a\u4ece\u5165\u95e8\u5230\u8fdb\u9636\uff0c\u4e00\u6587\u8bb2\u900f\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":116,"label":"\u514d\u75ab\u8367\u5149"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180134@2x-1024x1001.png",760,743,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":2,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":116,"name":"\u514d\u75ab\u8367\u5149","slug":"%e5%85%8d%e7%96%ab%e8%8d%a7%e5%85%89","term_group":0,"term_taxonomy_id":116,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1237"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1237\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1239"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1237"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}