{"id":1242,"date":"2026-03-26T02:57:47","date_gmt":"2026-03-26T02:57:47","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1242"},"modified":"2026-04-22T21:59:26","modified_gmt":"2026-04-22T21:59:26","slug":"glutamax","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/glutamax\/","title":{"rendered":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f"},"content":{"rendered":"\n<p>L-\u8c37\u6c28\u9170\u80fa\u662f\u7ec6\u80de\u57f9\u517b\u5fc5\u9700\u7684\u4e00\u79cd\u6c28\u57fa\u9178\uff0c\u53c2\u4e0e\u5176\u4ed6\u6c28\u57fa\u9178\u7684\u5f62\u6210\uff0c\u6838\u9178\u3001\u86cb\u767d\u8d28\u5408\u6210\u548c\u8461\u8404\u7cd6\u751f\u4ea7\u3002\u901a\u5e38\u6765\u8bf4\uff0c\u6dfb\u52a0\u5230\u57f9\u517b\u57fa\u4e2d\u7684L-\u8c37\u6c28\u9170\u80fa\u57284\u5ea6\u5b58\u653e\u65f6\u76f8\u5bf9\u6bd4\u8f83\u7a33\u5b9a\uff0c\u4f46\u5982\u679c\u5b58\u50a8\u4e0d\u5f53\uff0c<strong>\u5728\u9ad8\u4e8e 4\u00b0C \u7684\u6e29\u5ea6\u4e0b\uff0c\u7ec6\u80de\u57f9\u517b\u57fa\u4e2d\u7684 L-\u8c37\u6c28\u9170\u80fa\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u751f\u6210\u6709\u7ec6\u80de\u6bd2\u6027\u7684\u526f\u4ea7\u7269\u6c28\uff0c\u4ece\u800c\u5f71\u54cd\u86cb\u767d\u8d28\u7cd6\u57fa\u5316\uff0c\u51cf\u4f4e\u7ec6\u80de\u5b58\u6d3b\u7387\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662fglutamax\"><strong>\u4ec0\u4e48\u662fGlutaMAX?<\/strong><\/h2>\n\n\n\n<p id=\"h-\u4ec0\u4e48\u662fglutamax\">Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c<strong>\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff08\u56fe1\uff09\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff08\u56fe2\uff09\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002<\/strong>\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002<\/p>\n\n\n\n<p id=\"h-\u4ec0\u4e48\u662fglutamax\">\u5907\u6ce8\uff1a\u6b64\u6dfb\u52a0\u5242\u9002\u7528\u4e8e\u54fa\u4e73\u52a8\u7269\u7ec6\u80de\u57f9\u517b\u3002\u5efa\u8bae\u4e0d\u8981\u7528\u4e8e\u6606\u866b\u7ec6\u80de\u57f9\u517b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"648\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1-1024x648.png\" alt=\"\" class=\"wp-image-1244\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1-1024x648.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1-300x190.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1-768x486.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1.png 1106w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe1. DMEM\u57f9\u517b\u57fa\u4e2dGibco GlutaMAX\u6dfb\u52a0\u5242\u548cL-\u8c37\u6c28\u9170\u80fa\u7684\u7a33\u5b9a\u6027\u6bd4\u8f83\u3002<\/strong>\u5411DMEM\u4e2d\u5206\u522b\u52a0\u5165GlutaMAX\u6dfb\u52a0\u5242\u548cL-\u8c37\u6c28\u9170\u80fa\uff0c\u5206\u88c5\u6210\u5c0f\u74f6\u540e\u4e8e37\u2103\u4e0b\u5b58\u50a8\u3002\u6bcf\u5929\u53d6\u6837\u7f6e\u4e8e-20\u2103\u51bb\u5b58\u3002\u5229\u7528HPLC\u6cd5\u6d4b\u5b9aGlutaMAX\u6dfb\u52a0\u5242\u548cL-\u8c37\u6c28\u9170\u80fa\u7684\u6d53\u5ea6\u6c34\u5e73\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"647\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180630@2x-1024x647.png\" alt=\"\" class=\"wp-image-1245\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180630@2x-1024x647.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180630@2x-300x190.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180630@2x-768x485.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180630@2x.png 1098w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>\u56fe2. \u542b\u6dfb\u52a0\u5242\u57f9\u517b\u57fa\u4e2d\u7684\u6c28\u6c34\u5e73\u3002<\/strong>\u5411DMEM\u4e2d\u5206\u522b\u52a0\u5165GlutaMAX\u6dfb\u52a0\u5242\u548cL-\u8c37\u6c28\u9170\u80fa\uff0c\u5206\u88c5\u6210\u5c0f\u74f6\u540e\u4e8e37\u2103\u4e0b\u5b58\u50a8\u3002\u6bcf\u5929\u53d6\u6837\u7f6e\u4e8e-20\u2103\u51bb\u5b58\u3002\u5229\u7528HPLC\u6cd5\u6d4b\u5b9a\u6c28\u6c34\u5e73\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-glutamax\u5728\u514d\u75ab\u7ec6\u80de\u6cbb\u7597\u4e2d\u7684\u5e94\u7528\"><strong>GlutaMAX\u5728\u514d\u75ab\u7ec6\u80de\u6cbb\u7597\u4e2d\u7684\u5e94\u7528<\/strong><\/h2>\n\n\n\n<p>\u81ea\u4f53\u514d\u75ab\u7ec6\u80de\u6cbb\u7597\u4f5c\u4e3a\u4e00\u79cd\u514d\u75ab\u6cbb\u7597\u7b56\u7565\uff0c\u5728\u665a\u671f\u6076\u6027\u80bf\u7624\u60a3\u8005\u4e2d\u5c55\u73b0\u51fa\u5de8\u5927\u7684\u6f5c\u529b\uff0c\u4f9b\u4f53T\u7ec6\u80de\u7684\u4f53\u5916\u6269\u589e\u5219\u662f\u6280\u672f\u5173\u952e\u3002\u8d5b\u9ed8\u98de\u5e94\u7528\u6307\u5357\u6570\u636e\u8868\u660e\uff0c<strong>\u5728CTS OpTmizer T \u7ec6\u80de\u6269\u589e\u65e0\u8840\u6e05\u57f9\u517b\u57fa\uff08\u4e0d\u542b\u915a\u7ea2\uff09\u7684\u4f53\u7cfb\u4e2d\uff0c\u6dfb\u52a0 GlutaMAX\u53ef\u4ee5\u63d0\u9ad8T\u7ec6\u80de\u6d3b\u529b\uff1b<\/strong>\u6dfb\u52a0 CTS \u514d\u75ab\u7ec6\u80de\u8840\u6e05\u66ff\u4ee3\u54c1 (ISCR)\uff08\u4e00\u79cd\u5316\u5b66\u6210\u5206\u660e\u786e\u7684\u8840\u6e05\u66ff\u4ee3\u54c1\uff09\u53ef\u4ee5\u6539\u5584\u6269\u589e\u8fc7\u7a0b\u4e2d\u7684T\u7ec6\u80de\u751f\u957f\u901f\u7387\uff0c\u540c\u65f6\u4fdd\u6301\u7406\u60f3\u7684\u8868\u578b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"714\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180747@2x-1024x714.png\" alt=\"\" class=\"wp-image-1246\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180747@2x-1024x714.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180747@2x-300x209.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180747@2x-768x535.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180747@2x.png 1102w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 3. \u6dfb\u52a0 CTS ICSR \u548c GlutaMAX \u53ef\u63d0\u9ad8 CTS OpTmizer SFM\uff08\u4e0d\u542b\u915a\u7ea2\uff09\u7684\u6027\u80fd\u3002T\u7ec6\u80de\u5728\u6dfb\u52a0\u4e0d\u540c\u8425\u517b\u6210\u5206\u7684CTS OpTmizer SFM\uff08\u4e0d\u542b\u915a\u7ea2\uff09\u57f9\u517b\u57fa\u4e2d\uff0c\u4e8eG Rex\u57f9\u517b\u76bf\u4e2d\u57f9\u517b10\u5929\u3002\u5bf9\u7167\u7ec4\u4e3a\u5b8c\u5168\u57f9\u517b\u57fa\uff0c\u914d\u65b9\u89c1\u8bf4\u660e\u4e66\u3002\u5bf9\u7167\u7ec4\u7684\u53d8\u79cd\u5305\u62ec\u6dfb\u52a04mM GlutaMAX\u3001\u6dfb\u52a02.5% CTS ICSR\u4ee5\u53ca\u540c\u65f6\u6dfb\u52a04mM GlutaMAX\u548c2.5% ICSR\u3002(A) \u6d4b\u91cf\u7ec6\u80de\u968f\u65f6\u95f4\u63a8\u79fb\u7684\u751f\u957f\u60c5\u51b5\uff0c\u5e76\u4ee5\u500d\u6570\u6269\u589e\u8868\u793a\uff1b(B) \u76d1\u6d4b\u7ec6\u80de\u6d3b\u529b\u4ee5\u53ca\u7ec6\u80de\u6269\u589e\u60c5\u51b5<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" id=\"h-glutamax\u63d0\u4f9b\u591a\u79cd\u4ea7\u54c1\u9009\u62e9\"><strong>GlutaMAX\u63d0\u4f9b\u591a\u79cd\u4ea7\u54c1\u9009\u62e9<\/strong><\/h2>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-glutamax\u6dfb\u52a0\u5242\u6eb6\u6db2-\u8d27\u53f7-35050061\"><strong>GlutaMAX\u6dfb\u52a0\u5242\u6eb6\u6db2 (\u8d27\u53f7:\u00a0<a href=\"https:\/\/www.thermofisher.cn\/order\/catalog\/product\/35050061?icid=cn-blog-bid\">35050061<\/a>)\uff1a<\/strong><\/h3>\n\n\n\n<p>\u9002\u7528\u4e8e\u5b9e\u9a8c\u5ba4\u7814\u7a76\u6216\u65e9\u671f\u4e34\u5e8a\u7814\u53d1\uff0c\u5728\u60a8\u5f53\u524d\u7684\u7ec6\u80de\u57f9\u517b\u4f53\u7cfb\u4e2d\uff0c\u53ef\u76f4\u63a5\u4f7f\u7528\u6d53\u5ea6\u4e3a200 mM\u7684GlutaMAX\u6dfb\u52a0\u5242\u6eb6\u6db2\u66ff\u4ee3\u7b49\u6469\u5c14\u6d53\u5ea6\u7684L-\u8c37\u6c28\u9170\u80fa\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"678\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x-1024x678.png\" alt=\"\" class=\"wp-image-1247\" style=\"aspect-ratio:1.5096458959310326;width:438px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x-1024x678.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x-300x199.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x-768x509.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x-96x65.png 96w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180843@2x.png 1096w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-cts-glutamax\u6dfb\u52a0\u5242\u6eb6\u6db2-\u8d27\u53f7-a1286001\"><strong>CTS GlutaMAX\u6dfb\u52a0\u5242\u6eb6\u6db2 (\u8d27\u53f7:\u00a0<a href=\"https:\/\/www.thermofisher.cn\/order\/catalog\/product\/A1286001?icid=cn-blog-bid\">A1286001<\/a>)<\/strong><\/h3>\n\n\n\n<p>\u9002\u7528\u4e8e\u4e34\u5e8a\u8f6c\u5316\u7814\u7a76\uff0cL-\u8c37\u6c28\u9170\u80fa\u7684<strong>\u975e\u52a8\u7269\u6e90\u6027<\/strong>&nbsp;(AOF) \u4e8c\u80bd\u66ff\u4ee3\u54c1\uff0c\u4ee5\u7b26\u5408\u751f\u7269\u5de5\u827a\u8981\u6c42\u7684\u888b\u88c5\u5f62\u5f0f\u63d0\u4f9b\uff0c\u8154\u5ba4\u7531 Aegis 5-14 \u8584\u819c\u6784\u5efa\u3002\u5e26\u51f9\u578b\u9c81\u5c14\u9501\u7684\u65e0\u83cc\u3001\u53ef\u710a\u63a5 C-Flex\u2122 \u7ba1\u8def\u63d0\u4f9b\u4e86\u591a\u79cd\u8fde\u63a5\u9009\u9879\uff0c\u53ef\u96c6\u6210\u5230\u5bc6\u95ed\u7cfb\u7edf\u751f\u4ea7\u5de5\u827a\u4e2d\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"722\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180949@2x-1024x722.png\" alt=\"\" class=\"wp-image-1248\" style=\"aspect-ratio:1.4175346077785103;width:409px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180949@2x-1024x722.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180949@2x-300x212.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180949@2x-768x542.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180949@2x.png 1100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-glutamax\u6db2\u4f53\u57f9\u517b\u57fa\"><strong>GlutaMAX\u6db2\u4f53\u57f9\u517b\u57fa<\/strong><\/h3>\n\n\n\n<p>\u60a8\u53ef\u4ee5\u76f4\u63a5\u4f7f\u7528\u5df2\u6dfb\u52a0GlutaMAX\u7684\u6db2\u4f53\u57f9\u517b\u57fa\u4ea7\u54c1\uff0c\u6709\u591a\u79cd\u7ec4\u5206\u53ef\u4f9b\u9009\u62e9&nbsp;\uff1aDMEM\u3001DMEM\/F12\u3001MEM\u3001IMDM\u3001RPMI\u3001Opti-MEM\u7b49\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u8d44\u6599\">\u53c2\u8003\u8d44\u6599<\/h2>\n\n\n\n<p>Optimization of a Phenol Red&nbsp;Free T Cell&nbsp;Expansion Medium to Improve Performance and<\/p>\n\n\n\n<p>Workflow Flexibility. Evan Zynda and Pei-Yi Lin, Research and Development, Bioproduction, ThermoFisher Scientific, 3175 Staley Rd. Grand Island, NY 14072<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>L-\u8c37\u6c28\u9170\u80fa\u662f\u7ec6\u80de\u57f9\u517b\u5fc5\u9700\u7684\u4e00\u79cd\u6c28\u57fa\u9178\uff0c\u53c2\u4e0e\u5176\u4ed6\u6c28\u57fa\u9178\u7684\u5f62\u6210\uff0c\u6838\u9178\u3001\u86cb\u767d\u8d28\u5408\u6210\u548c\u8461\u8404\u7cd6\u751f\u4ea7\u3002\u901a\u5e38\u6765\u8bf4\uff0c\u6dfb\u52a0\u5230\u57f9<\/p>\n","protected":false},"author":1852,"featured_media":1243,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[11],"division":[9],"class_list":{"0":"post-1242","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-11","9":"division-bid","10":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f\" \/>\n<meta property=\"og:description\" content=\"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-26T02:57:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:26+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1106\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f\",\"datePublished\":\"2026-03-26T02:57:47+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/\"},\"wordCount\":116,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180617@2x.png\",\"keywords\":[\"\u7ec6\u80de\u57f9\u517b\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/\",\"name\":\"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180617@2x.png\",\"datePublished\":\"2026-03-26T02:57:47+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180617@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-180617@2x.png\",\"width\":1106,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/glutamax\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/","og_locale":"zh_CN","og_type":"article","og_title":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f","og_description":"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-26T02:57:47+00:00","article_modified_time":"2026-04-22T21:59:26+00:00","og_image":[{"width":1106,"height":700,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/glutamax\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f","datePublished":"2026-03-26T02:57:47+00:00","dateModified":"2026-04-22T21:59:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/glutamax\/"},"wordCount":116,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png","keywords":["\u7ec6\u80de\u57f9\u517b"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/glutamax\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/","name":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png","datePublished":"2026-03-26T02:57:47+00:00","dateModified":"2026-04-22T21:59:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"Gibco GlutaMAX\u662fL-\u8c37\u6c28\u9170\u80fa\u7684\u4e8c\u80bd\u5f62\u5f0f\uff08L-\u4e19\u6c28\u9170-L-\u8c37\u6c28\u9170\u80fa\uff09\uff0c\u5728\u6c34\u6eb6\u6db2\u4e2d\u6781\u4e3a\u7a33\u5b9a\uff0c\u5728\u957f\u671f\u50a8\u5b58\u548c\u57f9\u517b\u8fc7\u7a0b\u4e2d\u4e0d\u4f1a\u81ea\u53d1\u964d\u89e3\uff0c\u51cf\u5c11\u6c28\u7684\u751f\u6210\uff0c\u4ece\u800c\u63d0\u9ad8\u57f9\u517b\u57fa\u7684\u7a33\u5b9a\u6027\uff0c\u6700\u5927\u7a0b\u5ea6\u51cf\u5c11\u6709\u6bd2\u6210\u5206\u6c28\u7684\u7d2f\u79ef\uff0c\u4f18\u5316\u7ec6\u80de\u6027\u80fd\u3002\u8f83\u4f4e\u7684\u6c28\u6d53\u5ea6\u6709\u5229\u4e8e\u63d0\u9ad8\u7ec6\u80de\u4ea7\u7387\uff0c\u5c24\u5176\u662f\u5bf9\u6c28\u6bd2\u6027\u654f\u611f\u7684\u7ec6\u80de\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x.png","width":1106,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/glutamax\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"L-\u8c37\u6c28\u9170\u80fa\u6613\u964d\u89e3\u600e\u4e48\u529e\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":11,"label":"\u7ec6\u80de\u57f9\u517b"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-180617@2x-1024x648.png",760,481,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":11,"name":"\u7ec6\u80de\u57f9\u517b","slug":"%e7%bb%86%e8%83%9e%e5%9f%b9%e5%85%bb","term_group":0,"term_taxonomy_id":11,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1242","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1242"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1242\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1243"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1242"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1242"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1242"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}