{"id":1262,"date":"2026-03-24T04:40:31","date_gmt":"2026-03-24T04:40:31","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1262"},"modified":"2026-04-22T21:59:28","modified_gmt":"2026-04-22T21:59:28","slug":"qpcr-consumables-selection-principles","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/","title":{"rendered":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790"},"content":{"rendered":"\n<p>\u8fd1\u51e0\u5e74\uff0c\u4ece\u79d1\u5b66\u7814\u7a76\u5230\u4e34\u5e8a\u68c0\u6d4b\uff0c\u4ece\u201c\u975e\u6d32\u732a\u761f\u201d\u5230\u201c\u65b0\u51a0\u75c5\u6bd2\u201d\u68c0\u6d4b\uff0c<strong>\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR\uff08Real-Time Quantitative PCR\uff09<\/strong>\u5df2\u6210\u4e3a\u5206\u5b50\u751f\u7269\u5b66\u7814\u7a76\u7684\u4e3b\u8981\u6280\u672f\u4e4b\u4e00\u3002\u9664\u4e86\u9ad8\u8d28\u91cf\u7684\u68c0\u6d4b\u8bd5\u5242\u548c\u7a33\u5b9a\u7684qPCR\u4eea\u5668\uff0c\u5b9e\u9a8c\u8017\u6750\u4e5f\u5f71\u54cd\u7ed3\u679c\u7684\u51c6\u786e\u6027\u548c\u7075\u654f\u5ea6\uff0c\u5f88\u591a\u5f02\u5e38\u7684\u7ed3\u679c\u5c31\u662f\u7531\u4e8e\u8017\u6750\u6240\u5bfc\u81f4\u3002<\/p>\n\n\n\n<p>\u56e0\u6b64\uff0c\u5728\u5b9e\u9a8c\u5f00\u59cb\u4e4b\u524d\uff0c\u4e00\u5b9a\u8981\u786e\u4fdd\u8017\u6750\u7b26\u5408\u8981\u6c42\u3002\u5b9e\u9a8c\u4e2d\uff0c\u8981\u6b63\u786e\u4f7f\u7528\u8017\u6750\uff0c\u624d\u80fd\u8fbe\u5230\u4e8b\u534a\u529f\u500d\u7684\u6548\u679c\u3002\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd<strong>\u4e00\u4e9b\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9<\/strong>\u4ee5\u53ca<strong>\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879<\/strong>\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002<\/p>\n\n\n\n<p><strong>\u5728\u9009\u8d2dqPCR\u8017\u6750\u7684\u65f6\u5019\uff0c\u9700\u8981\u6ce8\u610f\u4ee5\u4e0b\u51e0\u4e2a\u8981\u70b9\uff1a&nbsp;<\/strong><\/p>\n\n\n\n<p><strong>1\u8017\u6750\u7684\u7eaf\u5ea6<\/strong><\/p>\n\n\n\n<p>qPCR\u8017\u6750\u901a\u5e38\u76f4\u63a5\u63a5\u89e6\u8bd5\u5242\u548c\u6837\u672c\uff0c\u8981\u6c42\u8868\u9762\u4e0d\u6613\u9644\u7740\u751f\u7269\u5206\u5b50\uff0c\u4e0d\u5e72\u6270\u8367\u5149\u4fe1\u53f7\u3002\u540c\u65f6\uff0c\u5b83\u8981\u5177\u6709\u4f18\u5f02\u7684\u5316\u5b66\u8010\u53d7\u6027\u548c\u6e29\u5ea6\u8010\u53d7\u6027\uff0c\u80fd\u627f\u53d7\u70ed\u5faa\u73af\u8fc7\u7a0b\u4e2d\u7684\u6e29\u5ea6\u6ce2\u52a8\u3002\u6b64\u5916\uff0c\u5bf9\u4e8e\u5bc6\u5c01\u819c\u548c\u7ba1\u76d6\uff0c\u8981\u6c42\u5176\u5177\u6709\u5149\u5b66\u900f\u660e\u6216\u8d85\u900f\u660e\u7684\u7279\u6027\uff0c\u4ee5\u51cf\u5c11\u8367\u5149\u4fe1\u53f7\u7684\u5931\u771f\uff0c\u4fdd\u8bc1\u6570\u636e\u7684\u51c6\u786e\u6027\u3002<\/p>\n\n\n\n<p><strong>2\u8017\u6750\u7684\u6d01\u51c0\u5ea6<\/strong><\/p>\n\n\n\n<p>qPCR\u8017\u6750\u5fc5\u987b\u6ca1\u6709\u6c61\u67d3\u7269\uff0c\u9632\u6b62\u7070\u5c18\u3001\u6838\u9178\u9176\u6216DNA\u6b8b\u7559\u7269\u5b58\u5728\uff0c\u8fd9\u4e9b\u7269\u8d28\u4e0d\u4ec5\u5f71\u54cd\u53cd\u5e94\u7684\u6269\u589e\uff0c\u8fd8\u5f71\u54cd\u4fe1\u53f7\u91c7\u96c6\u3002\u56e0\u6b64\uff0c\u8017\u6750\u751f\u4ea7\u4ee5\u53ca\u4fdd\u5b58\u5fc5\u987b\u5728\u4e25\u683c\u4e14\u6d01\u51c0\u7684\u73af\u5883\u4e2d\u3002<\/p>\n\n\n\n<p><strong>3\u8017\u6750\u7684\u6750\u8d28<\/strong><\/p>\n\n\n\n<p>\u786e\u4fdd\u6240\u9009\u62e9\u7684\u8017\u6750\u5728\u53cd\u5e94\u4e2d\u5177\u6709\u6700\u4f73\u70ed\u4f20\u5bfc\u7684\u7279\u6027\u3002\u5f53\u7136\uff0c\u8017\u6750\u7684\u58c1\u539a\u548c\u786c\u5ea6\u76f4\u63a5\u5f71\u54cd\u5b9e\u9a8c\uff0c\u5982\u679c\u7ba1\u58c1\u592a\u8584\uff0c\u5bb9\u6613\u5728\u64cd\u4f5c\u4e2d\u53d1\u751f\u7834\u88c2\uff1b\u8fd8\u6709\u4e00\u4e9b\u786c\u5ea6\u4e0d\u591f\u7684\u7ba1\u5b50\uff0c\u5728\u52a0\u70ed\u5faa\u73af\u8fc7\u7a0b\u4e2d\u7ba1\u5b50\u53d8\u5f62\uff0c\u5bfc\u81f4\u7ba1\u76d6\u5f39\u5f00\uff0c\u5bc6\u5c01\u6027\u964d\u4f4e\uff0c\u51fa\u73b0\u84b8\u53d1\u73b0\u8c61\uff0c\u5e76\u6c61\u67d3\u4eea\u5668\u3002<\/p>\n\n\n\n<p><strong>4\u8017\u6750\u7684\u5bc6\u5c01\u6027<\/strong><\/p>\n\n\n\n<p>\u4f18\u8d28\u7684\u8017\u6750\u662f\u6709\u9632\u84b8\u53d1\u4fdd\u62a4\u8bbe\u8ba1\u7684\uff0c\u786e\u4fdd\u53cd\u5e94\u5b54\u548c\u819c\u6216\u8005\u7ba1\u76d6\u4e4b\u95f4\u7684\u5bc6\u5c01\u6027\uff0c\u6765\u51cf\u5c11\u4ea4\u53c9\u6c61\u67d3\u4ee5\u53ca\u53cd\u5e94\u4f53\u7cfb\u5728\u5b9e\u9a8c\u8fc7\u7a0b\u4e2d\u84b8\u53d1\u3002\u9664\u4e86\u4ea7\u54c1\u672c\u8eab\uff0c\u5c01\u819c\u7684\u64cd\u4f5c\u8fc7\u7a0b\u4e5f\u5f88\u91cd\u8981\uff0c\u52a1\u5fc5\u786e\u4fdd\u819c\u6216\u7ba1\u76d6\u5c01\u597d\uff0c\u4ee5\u514d\u5f71\u54cd\u5b9e\u9a8c\u7ed3\u679c\u3002<\/p>\n\n\n\n<p><strong>5\u8017\u6750\u7684\u89c4\u683c<\/strong><\/p>\n\n\n\n<p>\u9009\u62e9\u5df2\u9a8c\u8bc1\uff0c\u4e14\u4e0e\u6240\u4f7f\u7528\u7684qPCR\u4eea\u517c\u5bb9\u7684\u8017\u6750\uff0c\u4ee5\u786e\u4fdd\u6700\u4f73\u7684\u9002\u914d\u6027\u548c\u6027\u80fd\u3002\u9002\u914d\u8017\u6750\u90fd\u6709\u4e25\u683c\u7684\u5c3a\u5bf8\u8981\u6c42\uff0c\u8017\u6750\u5c3a\u5bf8\u4e0a\u7684\u4e00\u4e9b\u5c0f\u7684\u504f\u5dee\u4e0d\u4ec5\u5f71\u54cd\u7ed3\u679c\uff0c\u8fd8\u4f1a\u5bfc\u81f4\u4eea\u5668\u8fd0\u884c\u62a5\u9519\uff0c\u5f71\u54cd\u4eea\u5668\u5bff\u547d\u3002<\/p>\n\n\n\n<p><strong>\u8017\u6750\u9009\u62e9\u56fa\u7136\u91cd\u8981\uff0c\u4f46\u64cd\u4f5c\u4f7f\u7528\u540c\u6837\u4e5f\u81f3\u5173\u91cd\u8981\u3002\u6b63\u786e\u7684\u64cd\u4f5c\u548c\u4f7f\u7528\u65b9\u6cd5\u53ef\u4ee5\u786e\u4fdd\u5b9e\u9a8c\u7ed3\u679c\u7684\u51c6\u786e\u6027\u548c\u53ef\u9760\u6027\u3002\u4ee5\u4e0b\u662f\u4e00\u4e9b\u5173\u952e\u70b9\uff1a<\/strong><\/p>\n\n\n\n<p><strong>01<\/strong> \u5b9e\u9a8c\u524d\uff0c\u786e\u4fdd\u8017\u6750\u662f\u4e0e\u4eea\u5668\u7684\u52a0\u70ed\u6a21\u5757\u9002\u914d\u7684\uff0c\u5982\u679c\u662f96-well 0.2mL\u7684\u52a0\u70ed\u6a21\u5757\uff0c\u4e00\u5b9a\u8981\u4f7f\u752896-well 0.2 mL\u7684\u8017\u6750\uff0c\u5982\u679c\u9519\u8bef\u4f7f\u7528\u4e8696-well 0.1 mL\u7684\u8017\u6750\uff0c\u867d\u7136\u4eea\u5668\u53ef\u4ee5\u6b63\u5e38\u8fd0\u884c\uff0c\u4f46\u662f\u7531\u4e8e0.1 mL\u7684\u8017\u6750\u4e0e0.2 mL\u7684\u52a0\u70ed\u6a21\u5757\u8d34\u5408\u4e0d\u7d27\u5bc6\uff0c\u6e29\u5ea6\u4f20\u8f93\u53ca\u63a7\u5236\u4e0d\u51c6\u786e\uff0c\u6700\u7ec8\u4f1a\u5bfc\u81f4\u6269\u589e\u5f02\u5e38\u3001\u91cd\u590d\u6027\u5dee\u7b49\u73b0\u8c61\u3002<\/p>\n\n\n\n<p><strong>02<\/strong> \u5b9e\u9a8c\u4e2d\uff0c\u4e00\u5b9a\u4e0d\u8981\u57288\u8fde\u7ba1\u7684\u7ba1\u76d6\u3001\u7ba1\u58c1\u6216\u8005\u53cd\u5e94\u677f\u7684\u819c\u4e0a\u505a\u4efb\u4f55\u6807\u8bb0\uff0c\u8fd9\u4e9b\u6807\u8bb0\u5728\u70ed\u5faa\u73af\u8fc7\u7a0b\u4e2d\u4f1a\u5f71\u54cd\u4fe1\u53f7\u91c7\u96c6\uff0c\u8fd8\u4f1a\u6c61\u67d3\u52a0\u70ed\u6a21\u5757\uff0c\u5bfc\u81f4\u7ed3\u679c\u5f02\u5e38\u3002\u6b64\u5916\uff0c\u914d\u7f6e\u4f53\u7cfb\u7684\u65f6\u5019\uff0c\u53cd\u5e94\u677f\u62168\u8fde\u7ba1\u5e94\u653e\u7f6e\u5728base\u4e0a\u9762\uff0c\u9632\u6b62\u64cd\u4f5c\u53f0\u6216\u79bb\u5fc3\u673a\u7b49\u53f0\u9762\u7684\u6c61\u67d3\u7269\u9ecf\u9644\u5728\u7ba1\u5e95\uff0c\u6c61\u67d3\u52a0\u70ed\u6a21\u5757\u3002<\/p>\n\n\n\n<p><strong>03<\/strong> \u4e0a\u673a\u65f6\uff0c\u8981\u6ce8\u610f\u6b63\u786e\u4f7f\u7528\u5bf9\u5e94\u7684\u914d\u4ef6\uff0c\u4f8b\u59827500\u4eea\u5668\u914d\u5957\u76848\u8fde\u7ba1\u7684\u6258\u67b6\u662f\u9ed1\u8272\u4e14\u56db\u5468\u5e26\u6709\u6d77\u7ef5\u7684\uff0c\u5982\u679c\u9519\u8bef\u4f7f\u7528\u53cd\u5e94\u677f\u7684\u4e0d\u5e26\u6709\u6d77\u7ef5\u7684\u6258\u67b6\uff0c\u5c06\u4f1a\u5bfc\u81f4\u7ed3\u679c\u5f02\u5e38\u3002\u6b64\u5916\uff0c\u5728\u4f7f\u75288\u8fde\u7ba1\u8fdb\u884c\u5b9e\u9a8c\u65f6\uff0c\u82e5\u6837\u672c\u8f83\u5c11\uff0c\u8981\u786e\u4fdd8\u8fde\u7ba1\u653e\u7f6e\u5728\u52a0\u70ed\u6a21\u5757\u4e2d\u95f4\uff0c\u5de6\u53f3\u4e24\u5217\u653e\u7f6e\u7a7a\u7ba1\u4f5c\u4e3a\u5e73\u8861\u652f\u6491\uff0c\u4fdd\u8bc1\u70ed\u76d6\u5de5\u4f5c\u65f6\u53d7\u529b\u5747\u5300\u3002<\/p>\n\n\n\n<p>\u82e5\u60a8\u4f7f\u7528\u7684\u662fApplied Biosystem\u7cfb\u5217\u7684qPCR\u4eea\u5668\uff0c\u53ef\u53c2\u8003\u516c\u4f17\u53f7\u4e4b\u524d\u7684\u4e00\u7bc7\u6587\u7ae0\u300a\u8d34\u58eb\uff1a\u6b63\u786e\u4f7f\u7528\u8367\u5149\u5b9a\u91cf\u4eea\u5668\u914d\u4ef6\u548c\u8017\u6750\uff08\u66f4\u65b0\u7248\u672c\uff09\u300b\u8fdb\u884c\u8017\u6750\u7684\u9009\u8d2d\u548c\u4f7f\u7528\u3002<\/p>\n\n\n\n<p>\u63a5\u4e0b\u6765\uff0c\u548c\u5927\u5bb6\u5206\u4eab\u51e0\u4e2a\u6bd4\u8f83\u5178\u578b\u7684\u5b9e\u9a8c\u8017\u6750\u5bfc\u81f4\u7ed3\u679c\u5f02\u5e38\u7684\u6848\u4f8b\uff0c\u8fd9\u4e9b\u90fd\u662f\u5e73\u65f6qPCR\u5b9e\u9a8c\u4e2d\u9047\u5230\u7684\uff0c\u4f9b\u5927\u5bb6\u53c2\u8003\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6848\u4f8b\u4e00\"><strong>\u6848\u4f8b\u4e00<\/strong><\/h2>\n\n\n\n<p>\u7b2c\u4e09\u65b9\u8017\u6750\u5bfc\u81f4\u62a5\u544a\u57fa\u56e2\u4fe1\u53f7\u5728\u57fa\u7ebf\u671f\u4fe1\u53f7\u4e0b\u964d\uff0c\u5bfc\u81f4\u66f2\u7ebf\u5f62\u6001\u5f02\u5e38\u3002Applied Biosystem\u7684qPCR\u4eea\u5668\u662f\u5f00\u653e\u4e14\u517c\u5bb9\u6027\u5f3a\u7684\u5e73\u53f0\uff0c\u5ba2\u6237\u53ef\u4ee5\u6839\u636e\u81ea\u5df1\u7684\u9700\u6c42\u4f7f\u7528\u7b2c\u4e09\u65b9\u7684\u8bd5\u5242\u548c\u8017\u6750\u3002\u4f46\u662f\uff0c\u76ee\u524d\u5e02\u9762\u4e0a\u7b2c\u4e09\u65b9\u8017\u6750\u54c1\u724c\u7e41\u591a\uff0c\u8d28\u91cf\u826f\u83a0\u4e0d\u9f50\uff0c\u6279\u6b21\u5dee\u5f02\u5927\uff0c\u5f71\u54cd\u5b9e\u9a8c\u7ed3\u679c\uff0c\u5ef6\u8bef\u9879\u76ee\u7b49\u3002\u6240\u4ee5\uff0c\u5927\u5bb6\u5728\u9009\u62e9\u8017\u6750\u7684\u65f6\u5019\uff0c\u52a1\u5fc5\u8981\u9009\u62e9\u54c1\u8d28\u5353\u8d8a\uff0c\u89c4\u683c\u5339\u914d\u7684\u4ea7\u54c1\uff0c\u4ece\u800c\u4fdd\u8bc1\u5b9e\u9a8c\u7ed3\u679c\u7684\u51c6\u786e\u3002\u4e0b\u56fe\u6848\u4f8b\u5c31\u662f\u4e00\u4e2a\u4f7f\u7528\u8d28\u91cf\u4e0d\u597d\u8017\u6750\u5bfc\u81f4\u4fe1\u53f7\u5f02\u5e38\u7684\u6848\u4f8b\uff0cFAM\u548cROX\u4fe1\u53f7\u5728\u57fa\u7ebf\u671f\u9010\u6e10\u4e0b\u964d\uff08\u56fe\u4e00\u5de6\uff09\uff0c\u901a\u8fc7\u6d4b\u8bd5\u6392\u67e5\uff0c\u63a8\u6d4b\u5ba2\u6237\u4f7f\u7528\u7684\u8017\u6750\u4e2d\u67d0\u79cd\u7ec4\u5206\u5f15\u8d77\u4fe1\u53f7\u4e0b\u964d\uff0c\u66f4\u6362\u5b98\u65b9\u8017\u6750\u540e\u4fe1\u53f7\u6b63\u5e38\uff08\u56fe\u4e00\u53f3\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"519\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1-1024x519.png\" alt=\"\" class=\"wp-image-1264\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1-1024x519.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1-300x152.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1-768x389.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1.png 1074w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u4e00\uff1a\u8d28\u91cf\u4e0d\u597d\u8017\u6750\u5bfc\u81f4\u8367\u5149\u4fe1\u53f7\u4e0d\u7a33\u5b9a(\u5de6)\u4ee5\u53ca\u66f4\u6362\u5b98\u914d\u8017\u6750\u540e\u7684\u7ed3\u679c(\u53f3)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6848\u4f8b\u4e8c\"><strong>\u6848\u4f8b\u4e8c<\/strong><\/h2>\n\n\n\n<p>\u5bf9\u4e8eqPCR\u8017\u6750\u6765\u8bf4\uff0c\u751f\u4ea7\u3001\u5305\u88c5\u3001\u8fd0\u8f93\u548c\u4f7f\u7528\u8fc7\u7a0b\u4e2d\uff0c\u6709\u53ef\u80fd\u4f1a\u63a5\u89e6\u5230\u7070\u5c18\u3001\u7ea4\u7ef4\u6216\u5176\u4ed6\u5fae\u5c0f\u9897\u7c92\uff0c\u4f1a\u5bfc\u81f4\u6742\u8d28\u8fdb\u5165\u53cd\u5e94\u5b54\uff0c\u6700\u7ec8\u5f71\u54cd\u5b9e\u9a8c\u3002\u56fe\u4e8c\u6848\u4f8b\u4e2d\uff0c\u5ba2\u6237\u53d1\u73b0\u5176\u4e2d\u4e00\u4e2a\u5b54\u4fe1\u53f7\u5f02\u5e38\uff08\u56fe\u4e8c\u5de6\uff09\uff0c\u67e5\u770b\u53cd\u5e94\u677f\u53d1\u73b0\uff0c\u53cd\u5e94\u5b54\u4e2d\u6709\u4e00\u4e2a\u9ed1\u8272\u7684\u6742\u8d28\uff0c\u53ef\u80fd\u662f\u7ba1\u5b50\u672c\u8eab\u6216\u8005\u64cd\u4f5c\u8fc7\u7a0b\u4e2d\u5e26\u5165\u3002\u540e\u7eed\u6362\u7528\u5e72\u51c0qPCR\u8017\u6750\u91cd\u65b0\u5b9e\u9a8c\uff0c\u7ed3\u679c\u6b63\u5e38\uff08\u56fe\u4e8c\u53f3\uff09\u3002\u56fe\u4e09\u6848\u4f8b\u4e2d\uff0c\u56fa\u5b9a\u5b54\u66f2\u7ebf\u5f02\u5e38\uff08\u56fe\u4e09\u5de6\uff09\uff0c\u6392\u67e5\u53d1\u73b0\u662f\u52a0\u70ed\u6a21\u5757\u6c61\u67d3\uff0c\u5ba2\u6237\u5b9e\u9a8c\u7684\u65f6\u5019\u6ca1\u6709\u7528base\u7684\u4e60\u60ef\uff0c\u76f4\u63a5\u653e\u7f6e\u5728\u5b9e\u9a8c\u53f0\u4e0a\uff0c\u53ef\u80fd\u662f\u7c98\u9644\u4e86\u4e00\u4e9b\u6c61\u67d3\u7269\uff0c\u6c61\u67d3\u4e86\u52a0\u70ed\u6a21\u5757\u3002\u6e05\u6d17\u8fc7\u540e\u91cd\u65b0\u5b9e\u9a8c\uff0c\u7ed3\u679c\u6b63\u5e38\uff08\u56fe\u4e09\u53f3\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"431\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182321@2x-1024x431.png\" alt=\"\" class=\"wp-image-1265\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182321@2x-1024x431.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182321@2x-300x126.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182321@2x-768x324.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182321@2x.png 1092w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u4e8c\uff1a\u7ba1\u4e2d\u6742\u8d28\u5bfc\u81f4\u4fe1\u53f7\u5f02\u5e38\u7684\u7ed3\u679c(\u5de6)\u4ee5\u53ca\u66f4\u6362\u5e72\u51c0\u8017\u6750\u540e\u7684\u6b63\u5e38\u7ed3\u679c(\u53f3)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"420\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182331@2x-1024x420.png\" alt=\"\" class=\"wp-image-1266\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182331@2x-1024x420.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182331@2x-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182331@2x-768x315.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182331@2x.png 1082w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u4e09\uff1a\u52a0\u70ed\u6a21\u5757\u88ab\u6c61\u67d3\u5bfc\u81f4\u66f2\u7ebf\u5f02\u5e38(\u5de6)\u4ee5\u53ca\u6a21\u5757\u6e05\u6d01\u540e\u66f2\u7ebf\u6b63\u5e38(\u53f3)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6848\u4f8b\u4e09\"><strong>\u6848\u4f8b\u4e09<\/strong><\/h2>\n\n\n\n<p>qPCR\u53cd\u5e94\u4f53\u7cfb\u662f\u5bc6\u5c01\u7684\uff0c\u6240\u4ee5\u8981\u786e\u4fdd\u53cd\u5e94\u5b54\u548c\u819c\u6216\u8005\u7ba1\u76d6\u4e4b\u95f4\u7684\u5bc6\u5c01\u6027\u4ee5\u51cf\u5c11\u4ea4\u53c9\u6c61\u67d3\u3002\u6709\u4e9b\u5382\u5bb6\u4e3a\u4e86\u964d\u4f4e\u6210\u672c\uff0c\u751f\u4ea7\u7684\u8017\u6750\u786c\u5ea6\u4f4e\uff0c\u7ba1\u5b50\u5bb9\u6613\u53d8\u5f62\u3002\u56fe\u56db\u6848\u4f8b\u4e2d\uff0c\u5ba2\u6237\u4f7f\u7528\u7684\u53cd\u5e94\u7ba1\u5728\u52a0\u70ed\u5faa\u73af\u8fc7\u7a0b\u4e2d\u53d8\u5f62\uff0c\u7ba1\u76d6\u5f39\u5f00\u5bc6\u5c01\u6027\u964d\u4f4e\uff0c\u4ea7\u7269\u84b8\u53d1\u6c61\u67d3\u4eea\u5668\u3002\u56fe\u516d\u6848\u4f8b\u4e2d\uff0c\u5ba2\u6237\u7684\u819c\u6ca1\u5c01\u597d\uff0c\u5728\u53cd\u5e94\u4e2d\u53d1\u751f\u201coptical warping\u201d\uff08\u56fe\u4e94\uff09\uff0c\u5bfc\u81f4\u6eb6\u89e3\u66f2\u7ebf\u51fa\u73b0\u591a\u4e2a\u5cf0\uff08\u56fe\u516d\u5de6\uff09\uff1b\u6362\u819c\u91cd\u65b0\u5c01\u597d\u819c\u540e\uff0c\u518d\u4e00\u6b21\u8fd0\u884c\u6eb6\u89e3\u66f2\u7ebf\uff0c\u7ed3\u679c\u6b63\u5e38\uff08\u56fe\u516d\u53f3\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"494\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182416@2x-1024x494.png\" alt=\"\" class=\"wp-image-1267\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182416@2x-1024x494.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182416@2x-300x145.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182416@2x-768x371.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182416@2x.png 1090w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u56db\uff1a\u56fd\u4ea7\u516b\u8fde\u7ba1\u7ba1\u76d6\u5f39\u5f00\u4f53\u7cfb\u84b8\u53d1\u5bfc\u81f4\u66f2\u7ebf\u5f02\u5e38(\u5de6)\u4ee5\u53ca\u6362\u7528\u5b98\u65b9\u8017\u6750\u540e\u66f2\u7ebf\u6b63\u5e38(\u53f3)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"402\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182426@2x-1024x402.png\" alt=\"\" class=\"wp-image-1268\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182426@2x-1024x402.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182426@2x-300x118.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182426@2x-768x302.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182426@2x.png 1054w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u4e94\uff1a\u819c\u6ca1\u5c01\u597d\uff0c\u5bfc\u81f4\u53cd\u5e94\u8fc7\u7a0b\u4e2d\u7684\u6c34\u84b8\u6c14\u4f7f\u819c\u53d8\u5f62<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"362\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182435@2x-1024x362.png\" alt=\"\" class=\"wp-image-1269\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182435@2x-1024x362.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182435@2x-300x106.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182435@2x-768x272.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182435@2x.png 1074w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u516d\uff1a\u5ba2\u6237\u819c\u6ca1\u5c01\u597d\u5bfc\u81f4\u6eb6\u89e3\u66f2\u7ebf\u5f02\u5e38(\u5de6)\u4ee5\u53ca\u91cd\u65b0\u5c01\u819c\u540e\u7684\u6b63\u5e38\u6eb6\u89e3\u66f2\u7ebf\u56fe(\u53f3)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6848\u4f8b\u56db\"><strong>\u6848\u4f8b\u56db<\/strong><\/h2>\n\n\n\n<p>qPCR\u8017\u6750\u7684\u89c4\u683c\u4e00\u5b9a\u8981\u9002\u914dqPCR\u4eea\u5668\uff0c\u4ee5\u4fdd\u8bc1\u5b9e\u9a8c\u6027\u80fd\u3002\u6709\u4e00\u4e9b\u7b2c\u4e09\u65b9\u7684\u8017\u6750\u4e0e\u5b98\u65b9\u8017\u6750\u5728\u5c3a\u5bf8\u4e0a\u6709\u4e00\u4e9b\u5c0f\u7684\u504f\u5dee\uff0c\u957f\u65f6\u95f4\u4f7f\u7528\uff0c\u4e0d\u4ec5\u5f71\u54cd\u7ed3\u679c\uff0c\u8fd8\u4f1a\u5f71\u54cd\u4eea\u5668\u5bff\u547d\u3002\u56fe\u4e03\u6848\u4f8b\u4e2d\uff0c\u5ba2\u6237\u957f\u65f6\u95f4\u4f7f\u7528\u7b2c\u4e09\u65b9\u8017\u6750\uff0c\u5176\u7565\u9ad8\u4e8e\u5b98\u65b9\u8017\u6750\uff0c\u957f\u65f6\u95f4\u4f7f\u7528\uff0c\u5bfc\u81f4\u4eea\u5668\u8fd0\u884c\u62a5\u9519\uff08\u56fe\u4e03\uff09\uff0c\u70ed\u76d6\u65e0\u6cd5\u590d\u4f4d\u3002\u6b64\u5916\uff0c\u5ba2\u6237\u8fd8\u7ecf\u5e38\u5728\u5b9e\u9a8c\u4e2d\u6df7\u7528\u5b9e\u9a8c\u5ba4\u8017\u6750\uff0c\u7279\u522b\u662f\u5b9e\u9a8c\u5ba4\u6709\u4e0d\u540c\u578b\u53f7\u4eea\u5668\u7684\u5ba2\u6237\uff0c\u5b9e\u9a8c\u4e2d\u4e00\u5b9a\u8981\u6ce8\u610f\u9009\u62e9\u9002\u914d\u7684\u8017\u6750\u3002\u6709\u5ba2\u6237\u957f\u9519\u8bef\u5c060.2 mL\u7684\u53cd\u5e94\u677f\u7528\u57280.1 mL\u6a21\u5757\u7684\u4eea\u5668\u4e0a\uff0c\u5bfc\u81f4\u4eea\u5668\u62a5\u9519\uff08\u56fe\u4e03\u6240\u793a\uff09\uff0c\u70ed\u76d6\u65e0\u6cd5\u590d\u4f4d\u3002\u56fe\u516b\u6848\u4f8b\u4e2d\uff0c\u5ba2\u6237\u9519\u8bef\u5c060.1 mL\u7684\u53cd\u5e94\u677f\u7528\u57280.2 mL\u6a21\u5757\u7684\u4eea\u5668\u4e0a\u5b9e\u9a8c\uff0c\u5bfc\u81f4\u5b54\u548c\u52a0\u70ed\u6a21\u5757\u8d34\u5408\u5ea6\u4e0d\u597d\uff0c\u90e8\u5206\u5b54\u6269\u589e\u53d7\u5230\u5f71\u54cd\uff0c\u5bfc\u81f4\u5185\u6807\u90fd\u6ca1\u6709\u6269\u589e\uff08\u56fe\u516b\u5de6\uff09\uff0c\u66f4\u63620.1 mL\u7684\u53cd\u5e94\u677f\u540e\u7ed3\u679c\u6b63\u5e38\uff08\u56fe\u516b\u53f3\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"476\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182530@2x-1024x476.png\" alt=\"\" class=\"wp-image-1270\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182530@2x-1024x476.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182530@2x-300x139.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182530@2x-768x357.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182530@2x.png 1114w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56fe\u4e03<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"400\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182539@2x-1024x400.png\" alt=\"\" class=\"wp-image-1271\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182539@2x-1024x400.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182539@2x-300x117.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182539@2x-768x300.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182539@2x.png 1100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u516b\uff1a0.2 mL\u6a21\u5757\u4eea\u5668\u4e0a\u4f7f\u75280.1 mL\u8017\u6750\u5bfc\u81f4\u5185\u6807\u6269\u589e\u5931\u8d25(\u5de6)\u4ee5\u53ca\u66f4\u63620.2 mL\u8017\u6750\u540e\u5185\u6807\u6269\u589e\u6b63\u5e38(\u53f3)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6848\u4f8b\u4e94\"><strong>\u6848\u4f8b\u4e94<\/strong><\/h2>\n\n\n\n<p>\u9009\u8d2d\u5339\u914d\u7684\u8017\u6750\u5f88\u91cd\u8981\uff0c\u6b63\u786e\u4f7f\u7528\u8017\u6750\u914d\u4ef6\u4e5f\u662f\u4e0d\u5bb9\u5ffd\u89c6\u7684\u3002\u56fe\u4f8b\u4e5d\u4e2d\uff0c\u5ba2\u6237\u4f7f\u75288\u8fde\u7ba1\u8fdb\u884c\u5b9e\u9a8c\uff0c\u4f46\u662f\u9519\u8bef\u9009\u62e996\u5b54\u677f\u7684\u6258\u67b6\uff0c\u5bfc\u81f4\u66f2\u7ebf\u4fe1\u53f7\u4e0d\u7a33\u5b9a\uff0c\u7ed3\u679c\u5f02\u5e38\u3002\u66f4\u6362\u6b63\u786e\u76848\u8fde\u7ba1\u6258\u67b6\u540e\uff0c\u7ed3\u679c\u6b63\u5e38\u3002&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"476\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182631@2x-1024x476.png\" alt=\"\" class=\"wp-image-1272\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182631@2x-1024x476.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182631@2x-300x139.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182631@2x-768x357.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182631@2x.png 1076w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe\u4e5d\uff1a8\u8fde\u7ba1\u9519\u8bef\u4f7f\u752896\u5b54\u677f\u6258\u67b6\u66f2\u7ebf\u5f02\u5e38(\u5de6)\u4ee5\u53ca\u66f4\u63628\u8fde\u7ba1\u6258\u67b6\u540e\u7684\u66f2\u7ebf(\u53f3)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8fd1\u51e0\u5e74\uff0c\u4ece\u79d1\u5b66\u7814\u7a76\u5230\u4e34\u5e8a\u68c0\u6d4b\uff0c\u4ece\u201c\u975e\u6d32\u732a\u761f\u201d\u5230\u201c\u65b0\u51a0\u75c5\u6bd2\u201d\u68c0\u6d4b\uff0c\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR\uff08Real-Time Qua<\/p>\n","protected":false},"author":1852,"featured_media":1263,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[16,17],"division":[10],"class_list":{"0":"post-1262","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-qpcr","9":"tag-pcr","10":"division-gsd","11":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T04:40:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1074\" \/>\n\t<meta property=\"og:image:height\" content=\"544\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790\",\"datePublished\":\"2026-03-24T04:40:31+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/\"},\"wordCount\":47,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-182225@2x.png\",\"keywords\":[\"qPCR\",\"\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/\",\"name\":\"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-182225@2x.png\",\"datePublished\":\"2026-03-24T04:40:31+00:00\",\"dateModified\":\"2026-04-22T21:59:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-182225@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260323-182225@2x.png\",\"width\":1074,\"height\":544},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/qpcr-consumables-selection-principles\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/","og_locale":"zh_CN","og_type":"article","og_title":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790","og_description":"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-24T04:40:31+00:00","article_modified_time":"2026-04-22T21:59:28+00:00","og_image":[{"width":1074,"height":544,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790","datePublished":"2026-03-24T04:40:31+00:00","dateModified":"2026-04-22T21:59:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/"},"wordCount":47,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png","keywords":["qPCR","\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/","name":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png","datePublished":"2026-03-24T04:40:31+00:00","dateModified":"2026-04-22T21:59:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u672c\u6587\u5c06\u7ed9\u5927\u5bb6\u4ecb\u7ecd\u4e00\u4e9bqPCR\u8017\u6750\u9009\u62e9\u7684\u8981\u70b9\u4ee5\u53ca\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u7ed3\u5408\u51e0\u4e2a\u6848\u4f8b\uff0c\u5e26\u7740\u5927\u5bb6\u4e00\u8d77\u770b\u4e00\u4e0b\u5e38\u89c1\u7684\u7531\u4e8e\u8017\u6750\u95ee\u9898\u800c\u5bfc\u81f4\u7684\u5f02\u5e38\u7ed3\u679c\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x.png","width":1074,"height":544},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/qpcr-consumables-selection-principles\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"qPCR\u8017\u6750\u9009\u8d2d\u539f\u5219\u53ca\u5f02\u5e38\u6848\u4f8b\u5206\u6790"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":16,"label":"qPCR"},{"value":17,"label":"\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR"}],"division":[{"value":10,"label":"GSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260323-182225@2x-1024x519.png",760,385,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":16,"name":"qPCR","slug":"qpcr","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":17,"name":"\u5b9e\u65f6\u8367\u5149\u5b9a\u91cfPCR","slug":"%e5%ae%9e%e6%97%b6%e8%8d%a7%e5%85%89%e5%ae%9a%e9%87%8fpcr","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1262","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1262"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1262\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1263"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1262"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1262"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1262"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}