{"id":1330,"date":"2026-03-26T03:35:45","date_gmt":"2026-03-26T03:35:45","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1330"},"modified":"2026-04-22T21:59:26","modified_gmt":"2026-04-22T21:59:26","slug":"absolute-q-digital-pcr-gmo-quantification","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\/","title":{"rendered":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528"},"content":{"rendered":"<div style=\"background: linear-gradient(180deg,#f7f3e8 0%,#f4efe4 100%);padding: 32px 0;color: #1c2740;font-family: 'Segoe UI','PingFang SC','Microsoft YaHei',sans-serif\">\n<div style=\"max-width: 1120px;margin: 0 auto;padding: 0 16px\">\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<p style=\"margin: 0;font-size: 18px;line-height: 1.85;color: #334155\">Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u53ef\u7528\u4e8e\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u3002\u672c\u6587\u7ed3\u5408\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u4e0e\u5b9a\u91cf\u9650\u7ed3\u679c\uff0c\u5c55\u793a\u8be5\u5e73\u53f0\u5728GMO\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\u8868\u73b0\u3002<\/p>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u7b80\u4ecb<\/h2>\n<ul style=\"margin: 0;padding-left: 20px;line-height: 1.95;color: #344054\">\n<li>\u6570\u5b57PCR\u662f\u5426\u9002\u5408\u7528\u4e8e\u8f6c\u57fa\u56e0\u6210\u5206\u7684\u7edd\u5bf9\u5b9a\u91cf\u68c0\u6d4b\u3002<\/li>\n<li>QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5982\u4f55\u652f\u6301GMO\u6837\u54c1\u68c0\u6d4b\u3002<\/li>\n<li>\u57283%\u30011%\u30010.1%\u30010.05%\u30010.01%\u7b49\u4e0d\u540c\u6c34\u5e73\u4e0b\uff0c\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u8868\u73b0\u5982\u4f55\u3002<\/li>\n<li>\u8fd9\u4e00\u65b9\u6848\u9002\u5408\u54ea\u4e9b\u519c\u4e1a\u98df\u54c1\u68c0\u6d4b\u4e0e\u65b9\u6cd5\u5f00\u53d1\u573a\u666f\u3002<\/li>\n<\/ul>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u8981\u70b9\u6982\u89c8<\/h2>\n<ul style=\"margin: 0;padding-left: 20px;line-height: 1.95;color: #344054\">\n<li>\u6570\u5b57PCR\u65e0\u9700\u4f9d\u8d56\u6807\u51c6\u66f2\u7ebf\uff0c\u53ef\u7528\u4e8e\u8f6c\u57fa\u56e0\u6210\u5206\u7edd\u5bf9\u5b9a\u91cf\u3002<\/li>\n<li>Absolute Q\u91c7\u7528\u82af\u7247\u5f0f\u6570\u5b57PCR\u8def\u7ebf\uff0c\u6d41\u7a0b\u96c6\u6210\u5ea6\u9ad8\uff0c\u9002\u5408\u6807\u51c6\u5316\u68c0\u6d4b\u5de5\u4f5c\u6d41\u3002<\/li>\n<li>\u6587\u4e2d\u5b9e\u9a8c\u663e\u793a\u8be5\u7cfb\u7edf\u5728\u591a\u4e2a GMO \u542b\u91cf\u68af\u5ea6\u4e0b\u5177\u6709\u826f\u597d\u7684\u51c6\u786e\u6027\u3001\u91cd\u590d\u6027\u4e0e\u518d\u73b0\u6027\u3002<\/li>\n<li>\u5b9a\u91cf\u9650\u53ef\u8fbe\u52300.01%\u6c34\u5e73\uff0c\u9002\u5408\u4f4e\u4e30\u5ea6\u6837\u672c\u68c0\u6d4b\u573a\u666f\u3002<\/li>\n<\/ul>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u80cc\u666f<\/h2>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u8f6c\u57fa\u56e0\u6280\u672f\u662f\u5229\u7528\u57fa\u56e0\u5de5\u7a0b\u624b\u6bb5\u5c06\u5916\u6e90\u57fa\u56e0\u5bfc\u5165\u751f\u7269\u4f53\u57fa\u56e0\u7ec4\u5e76\u4f7f\u4e4b\u8868\u73b0\u51fa\u9884\u671f\u6027\u72b6\u7684\u6280\u672f\uff0c\u8be5\u6280\u672f\u7528\u4e8e\u73b0\u4ee3\u519c\u4e1a\u751f\u4ea7\u540e\uff0c\u57f9\u80b2\u4e86\u8bb8\u591a\u5177\u6709\u6297\u75c5\u866b\u3001\u8010\u9664\u8349\u5242\u3001\u6297\u975e\u751f\u7269\u80c1\u8feb\u3001\u54c1\u8d28\u6539\u826f\u7b49\u4f18\u826f\u6027\u72b6\u7684\u8f6c\u57fa\u56e0\u690d\u7269\u3002\u968f\u7740\u8f6c\u57fa\u56e0\u6280\u672f\u7684\u53d1\u5c55\u548c\u8f6c\u57fa\u56e0\u751f\u7269(Genetically Modified Organism, \u7b80\u79f0GMO)\u7684\u65e5\u76ca\u666e\u53ca\uff0c\u8f6c\u57fa\u56e0\u4ea7\u54c1\u8fdb\u5165\u5e02\u573a\u7684\u79cd\u7c7b\u548c\u6570\u91cf\u8d8a\u6765\u8d8a\u591a\uff0c\u4e3a\u4fdd\u62a4\u6d88\u8d39\u8005\u7684\u77e5\u60c5\u6743\uff0c\u6211\u56fd\u9881\u5e03\u5b9e\u65bd\u4e86\u8f6c\u57fa\u56e0\u4ea7\u54c1\u7684\u6807\u8bc6\u5236\u5ea6\u3002\u4e3a\u4e86\u4fdd\u969c\u8f6c\u57fa\u56e0\u6807\u8bc6\u5236\u5ea6\u7684\u987a\u5229\u5b9e\u65bd\uff0c\u5efa\u7acb\u7cbe\u786e\u6709\u6548\u7684\u68c0\u6d4b\u65b9\u6cd5\u5c24\u4e3a\u91cd\u8981\uff0c\u5bf9\u4e8e\u68c0\u6d4b\u65b9\u6cd5\u5b9a\u91cf\u7684\u51c6\u786e\u6027\u63d0\u51fa\u4e86\u5f88\u9ad8\u7684\u8981\u6c42[1]\u3002\u6570\u5b57PCR\u662f\u4e00\u79cd\u4e0d\u4f9d\u8d56\u4e8e\u6807\u51c6\u7269\u8d28\u548c\u6807\u51c6\u66f2\u7ebf\u80fd\u5bf9\u6838\u9178\u8fdb\u884c\u7edd\u5bf9\u5b9a\u91cf\u7684\u68c0\u6d4b\u6280\u672f\uff0c\u5728\u8f6c\u57fa\u56e0\u4f5c\u7269\u53ca\u5176\u4ea7\u54c1\u7684\u5b9a\u91cf\u68c0\u6d4b\uff0c\u4ee5\u53ca\u8f6c\u57fa\u56e0\u68c0\u6d4b\u6807\u51c6\u7269\u8d28\u7684\u7814\u5236\u4e2d\u7684\u5e94\u7528\u8d8a\u6765\u8d8a\u5e7f\u6cdb[2]\u3002<\/p>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">2017\u5e742\u670828\u65e5\u53d1\u5e03\uff0c2017\u5e749\u67081\u65e5\u5b9e\u65bd\u7684\u56fd\u6807 GB\/T 33526-2017\u300a\u8f6c\u57fa\u56e0\u690d\u7269\u4ea7\u54c1\u6570\u5b57PCR\u68c0\u6d4b\u65b9\u6cd5\u300b\u4e2d\u89c4\u5b9a\u4e86\u8f6c\u57fa\u56e0\u6210\u5206\u68c0\u6d4b\u7684\u6570\u5b57PCR\u65b9\u6cd5\uff0c\u9002\u7528\u4e8e\u7389\u7c73\u3001\u5927\u8c46\u3001\u6cb9\u83dc\u3001\u6c34\u7a3b\u3001\u9a6c\u94c3\u85af\u3001\u82dc\u84ff\u3001\u68c9\u82b1\u7b49\u8f6c\u57fa\u56e0\u690d\u7269\u53ca\u5176\u4ea7\u54c1\u7684\u8f6c\u57fa\u56e0\u6210\u5206\u6570\u5b57PCR\u68c0\u6d4b\uff0c\u6240\u80fd\u8fbe\u5230\u7684\u68c0\u6d4b\u4f4e\u9650\u4e3a0.1%\u3002\u56fd\u6807\u4e2d\u6307\u51fa\uff0c\u6570\u5b57PCR\u5176\u6280\u672f\u539f\u7406\u662f\u901a\u8fc7\u5c06\u539f\u59cbPCR\u53cd\u5e94\u4f53\u7cfb\u8fdb\u884c\u5206\u5272\uff0c\u8fdb\u800c\u5bf9\u6240\u6709\u5c0f\u7684\u53cd\u5e94\u4f53\u7cfb\u8fdb\u884c\u6269\u589e\u5e76\u540e\u7eed\u68c0\u6d4b\u3002\u901a\u8fc7\u5bf9\u53cd\u5e94\u4f53\u7cfb\u8fdb\u884c\u6709\u9650\u7684\u5206\u5272\uff0c\u4ece\u800c\u4f7f\u6574\u4e2a\u53cd\u5e94\u4f53\u7cfb\u53ef\u4ee5\u66f4\u52a0\u8010\u53d7\u6838\u9178\u6291\u5236\u56e0\u5b50\uff0c\u5e76\u4e14\u66f4\u52a0\u7a33\u5b9a\u3001\u51c6\u786e\u3001\u5feb\u901f\u5730\u5bf9\u75d5\u91cf\u7684\u8f6c\u57fa\u56e0\u6210\u5206\u8fdb\u884c\u7cbe\u51c6\u9274\u5b9a\u3002\u5176\u4e2d\u5fae\u6ef4\u5f0f\u6570\u5b57PCR\u7684\u6cb9\u5305\u6c34\u5206\u5272\u65b9\u5f0f\u7684\u7a33\u5b9a\u6027\u8f83\u5dee\uff0c\u800c\u4e14\u5bf9\u4e8e\u6570\u636e\u5206\u6790\u7684\u8981\u6c42\u4e5f\u76f8\u5bf9\u8f83\u9ad8\uff0c\u800c\u82af\u7247\u5f0f\u6570\u5b57PCR\u901a\u8fc7\u5fae\u6d41\u63a7\u82af\u7247\u5b9e\u73b0\u5bf9\u539f\u59cb\u53cd\u5e94\u4f53\u7cfb\u7684\u5206\u5272\uff0c\u8fd9\u79cd\u5206\u5272\u65b9\u5f0f\u5177\u6709\u7a33\u5b9a\u6027\u597d\u3001\u5747\u4e00\u6027\u597d\u7684\u4f18\u70b9\u3002Applied Biosystems QuantStudio Absolute Q\u82af\u7247\u5f0f\u6570\u5b57PCR\u7cfb\u7edf\u91c7\u7528\u82af\u7247\u5f0f\u6570\u5b57PCR\u539f\u7406\uff0c\u80fd\u591f\u7b80\u6d01\u3001\u5feb\u901f\u3001\u51c6\u786e\u5730\u5b8c\u6210\u8f6c\u57fa\u56e0\u7684\u68c0\u6d4b\u548c\u5b9a\u91cf\u3002<\/p>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">QuantStudio Absolute Q\u6570\u5b57PCR\u5e73\u53f0<\/h2>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u6570\u5b57PCR(dPCR)\u662f\u4e00\u79cd\u5168\u65b0\u7684\u6838\u9178\u68c0\u6d4b\u548c\u5b9a\u91cf\u65b9\u6cd5\u3002\u6570\u5b57PCR\u662f\u5c06\u4e00\u4efd\u6837\u54c1\u5206\u914d\u5230\u6570\u4e07\u4e2a\u53cd\u5e94\u5355\u5143\u4e2d\uff0c\u800c\u8fd9\u4e9b\u53cd\u5e94\u5355\u5143\u4e2d\u53ea\u6709\u90e8\u5206\u542b\u6709\u76ee\u6807\u5206\u5b50\u3002\u5728\u7ecf\u8fc7PCR\u6269\u589e\u548c\u4fe1\u53f7\u5206\u6790\u540e\uff0c\u91c7\u7528\u6cca\u677e\u5206\u5e03\u6765\u8ba1\u7b97\u6837\u54c1\u4e2d\u76ee\u6807\u5206\u5b50\u6570\uff0c\u65e0\u9700\u6807\u51c6\u54c1\u5373\u53ef\u5b8c\u6210\u7edd\u5bf9\u6d53\u5ea6\u7684\u5b9a\u91cf\u3002<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 760px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/platform_principle-8.png\" alt=\"\u6570\u5b57PCR\u539f\u7406\u56fe\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u56fe1. \u6570\u5b57PCR\u539f\u7406<\/figcaption>\n<\/figure>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u5bf9\u4e8e\u9700\u8981\u9ad8\u7075\u654f\u5ea6\u3001\u9ad8\u7cbe\u5ea6\u548c\u51c6\u786e\u5ea6\u7684\u68c0\u6d4b\uff0cQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u662f\u4e00\u79cd\u7406\u60f3\u9009\u62e9\u3002QuantStudio Absolute Q\u662f\u57fa\u4e8e\u5fae\u6d41\u4f53\u9635\u5217\u5f0f\u82af\u7247\u7684\u6570\u5b57PCR\u7cfb\u7edf\uff0c\u8be5\u7cfb\u7edf\u5c06\u6db2\u6ef4\u751f\u6210\u3001\u6db2\u6ef4\u6269\u589e\u548c\u6570\u636e\u5206\u6790\u96c6\u6210\u5230\u4e00\u4f53\u5316\u4eea\u5668\u4e2d\uff0c\u5176\u5b9e\u9a8c\u6d41\u7a0b\u5982\u540cqPCR\u5b9e\u9a8c\u4e00\u822c\uff0c\u5b9e\u73b0\u57281.5\u5c0f\u65f6\u5185\u4ece\u6837\u672c\u5230\u6570\u636e\u7ed3\u679c\u7684\u5feb\u901f\u7b80\u4fbf\u5de5\u4f5c\u6d41\u7a0b\u3002\u7cfb\u7edf\u91c7\u7528\u5177\u6709\u4e13\u5229\u7684\u5fae\u6d41\u4f53\u9635\u5217\u5f0f\u82af\u7247\u6280\u672f\u3002\u76f8\u6bd4\u4e8e\u5176\u4ed6\u6570\u5b57PCR\u5e73\u53f0\uff0c\u8be5\u7cfb\u7edf\u53ef\u572820480\u4e2a\u56fa\u5b9a\u7eb3\u7c73\u7ea7\u5fae\u5b54\u4e2d\u751f\u621095%\u4ee5\u4e0a\u7684\u6709\u6548\u53cd\u5e94\u6db2\u6ef4\uff0c\u5177\u6709\u66f4\u5c11\u7684\u6b7b\u4f53\u79ef\uff08\u4e0a\u6837\u4f53\u79ef\u4e0e\u5b9e\u9645\u5206\u6790\u4f53\u79ef\u4e4b\u5dee\uff09\uff0c\u4ece\u800c\u83b7\u5f97\u66f4\u7cbe\u51c6\u7684\u5b9e\u9a8c\u7ed3\u679c\u3002<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 920px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/experiment_flow-8.png\" alt=\"\u6570\u5b57PCR\u5b9e\u9a8c\u6d41\u7a0b\u56fe\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u56fe2. \u6570\u5b57PCR\u5b9e\u9a8c<\/figcaption>\n<\/figure>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u68c0\u6d4b\u65b9\u6cd5<\/h2>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u63a2\u9488\u5f15\u7269\u8bbe\u8ba1<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u4f7f\u7528\u7684\u63a2\u9488\u5f15\u7269\u65e0\u7279\u522b\u4e4b\u5904\u3002\u56fd\u5bb6\u6807\u51c6\u548c\u884c\u4e1a\u6807\u51c6\u4e2d\u9488\u5bf9qPCR\u6280\u672f\u63a8\u8350\u7684\u5404\u79cd\u63a2\u9488\u5f15\u7269\u4e5f\u540c\u6837\u9002\u7528\u4e8e\u6570\u5b57PCR\u3002\u5982\u679c\u60a8\u624b\u5934\u6709qPCR\u65e5\u5e38\u68c0\u6d4b\u7528\u7684\u63a2\u9488\u5f15\u7269\u4ee5\u53ca\u6837\u54c1\uff0c\u5373\u53ef\u4ee5\u5f00\u5c55QuantStudio Absolute Q\u6570\u5b57PCR\u5b9e\u9a8c\u3002\u672c\u5b9e\u9a8c\u7684\u63a2\u9488\u5f15\u7269\u5982\u4e0b\uff1a<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 920px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/assay_table-8.png\" alt=\"\u63a2\u9488\u5f15\u7269\u8bbe\u8ba1\u8868\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4f7f\u7528\u7684\u63a2\u9488\u5f15\u7269<\/figcaption>\n<\/figure>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u6837\u54c1\u51c6\u5907<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u5728\u672c\u5b9e\u9a8c\u4e2d\uff0c\u6211\u4eec\u5206\u522b\u91c7\u7528\u8f6c\u57fa\u56e0\u7389\u7c73DBN9858\u54c1\u79cd\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf100%\u7684\u6807\u51c6\u7269\u8d28DNA\u4e0eDBN9858\u975e\u8f6c\u57fa\u56e0\u53d7\u4f53\u7684DNA\u8fdb\u884c\u6df7\u5408\uff0c\u5236\u5907\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u57283%\u30011%\u30010.1%\u30010.05%\u6c34\u5e73\u7684\u6837\u672c\uff1b\u8f6c\u57fa\u56e0\u7389\u7c73DBN9936\u54c1\u79cd\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf5%\u7684\u6807\u51c6\u7269\u8d28DNA\u4e0eDBN9936\u975e\u8f6c\u57fa\u56e0\u53d7\u4f53\u7684DNA\u8fdb\u884c\u6df7\u5408\uff0c\u5236\u5907\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u57283%\u30011%\u30010.1%\u30010.05%\u30010.01%\u6c34\u5e73\u7684\u6837\u672c\uff0c\u4ee5\u9a8c\u8bc1QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u5b9a\u91cf\u53ca\u5b9a\u6027\u68c0\u6d4b\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u65b9\u9762\u7684\u7cbe\u5bc6\u5ea6\u548c\u7075\u654f\u5ea6\u6027\u80fd\u3002\u672c\u5b9e\u9a8cDBN9858\u3001DBN9936\u6807\u51c6\u7269\u8d28DNA\u53ca\u5bf9\u5e94\u7684\u975e\u8f6c\u57fa\u56e0\u53d7\u4f53DNA\u5747\u7531\u4e2d\u56fd\u519c\u4e1a\u79d1\u5b66\u9662\u6cb9\u6599\u4f5c\u7269\u7814\u7a76\u6240\u63d0\u4f9b\u3002<\/p>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u6570\u5b57PCR\u53cd\u5e94\u4f53\u7cfb\u914d\u5236<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u652f\u63015\u4e2a\u8367\u5149\u68c0\u6d4b\u901a\u9053\uff0c\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\uff0c\u5c31\u53ef\u4ee5\u5b9e\u73b0\u540c\u4e00\u68c0\u6d4b\u5b54\u4e2d\uff0c\u5bf9\u8f6c\u57fa\u56e0\u5143\u4ef6\u548c\u5185\u6e90\u57fa\u56e0\u8fdb\u884c\u53cc\u91cd\u9776\u6807\u68c0\u6d4b\u3002<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 520px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/reagent_table-8.png\" alt=\"\u6570\u5b57PCR\u53cd\u5e94\u4f53\u7cfb\u8868\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u88681. \u6570\u5b57PCR\u53cd\u5e94\u4f53\u7cfb<\/figcaption>\n<\/figure>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u4e0a\u6837\u82af\u7247\u677f\u8fd0\u884c\u5b9e\u9a8c<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u4e00\u3001\u53cd\u5e94\u4f53\u7cfb\u914d\u5236\u53ca\u51c6\u5907\uff1a\u6309\u4e0a\u8868\u914d\u5236\u53cd\u5e94\u4f53\u7cfb\uff0c\u5145\u5206\u6df7\u5408\u53cd\u5e94\u4f53\u7cfb\uff0c10,000 x g\u79bb\u5fc31\u5206\u949f\u3002<\/p>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u4e8c\u3001\u5c06\u53cd\u5e94\u4f53\u7cfb\u52a0\u81f3QS Absolute Q MAP16\u82af\u7247\u677f\uff1a\u63e1\u4f4fMAP\u82af\u7247\u677f\u7684\u6846\u67b6\uff0c\u5728\u5e73\u6574\u3001\u65e0\u5c18\u7684\u5e73\u9762\u4e0a\u64cd\u4f5c\u3002\u6bcf\u4e2a\u5b54\u52a0\u5165\u4e00\u4e2a\u53cd\u5e94\u4f53\u7cfb\u3002\u4ee545\u00b0\u89d2\uff0c\u5c069\u00b5L\u7684dPCR\u53cd\u5e94\u4f53\u7cfb\u52a0\u5165\u5b54\u5e95\u3002\u4ec5\u4f7f\u7528\u79fb\u6db2\u5668\u81f3\u7b2c\u4e00\u6863\u5373\u53ef\u3002\u4ee545\u00b0\u89d2\uff0c\u52a015\u00b5L\u5206\u79bb\u5c01\u95ed\u7f13\u51b2\u6db2\u3002\u4ec5\u4f7f\u7528\u79fb\u6db2\u5668\u81f3\u7b2c\u4e00\u6863\u3002\u5728MAP\u82af\u7247\u677f\u4e0a\u76d6\u4e0a5\u4e2a\u82af\u7247\u80f6\u57ab\u3002<\/p>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u4e09\u3001\u8bbe\u7f6e\u8fd0\u884c\uff1a\u9009\u62e9\u5df2\u88c5\u8f7d\u7684MAP\u82af\u7247\u5217\uff1b\u8bbe\u7f6ePCR\u53c2\u6570\u300296\u2103\u9884\u70ed10\u5206\u949f\uff1b96\u2103 5\u79d2\uff1b60\u2103 15\u79d2\uff0c\u5faa\u73af\u657040\uff1b\u9009\u62e9\u8367\u5149\u901a\u9053\u3002\u786e\u5b9a\u82af\u7247\u80f6\u57ab\u65b9\u5411\uff0c\u4f7fA\u6807\u8bb0\u5728\u82af\u7247\u9876\u90e8\uff0c\u9009\u62e9\u201c\u5f00\u59cb\u201d\uff0c\u8fd0\u884c\u5b9e\u9a8c\u3002QuantStudio Absolute Q Digital PCR Software\u63a7\u5236\u5206\u6790\u8f6f\u4ef6\uff0c\u53ef\u8f7b\u677e\u7f16\u8f91\u677f\u9762\u5e03\u5c40\u3001\u8367\u5149\u901a\u9053\u548c\u70ed\u5faa\u73af\u7a0b\u5e8f\u7b49\u53c2\u6570\uff0c\u53ef\u4ee5\u5feb\u901f\u8fd0\u884c\u5b9e\u9a8c\u3002<\/p>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u5b9e\u9a8c\u7ed3\u679c<\/h2>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u4eea\u5668\u8fd0\u884c\u7ed3\u675f\u540e\u7528\u6237\u53ef\u7528QuantStudio Absolute Q Digital PCR Software\u67e5\u770b\u6570\u636e\u7ed3\u679c\uff0c\u8f6f\u4ef6\u754c\u9762\u53ef\u4ee5\u67e5\u770bMAP16\u82af\u7247\u677f\u5bf9\u5e94\u7684\u6bcf\u4e2a\u68c0\u6d4b\u5b54\u7684\u6709\u6548\u5fae\u5b54\u6570\u636e\u3001\u9634\u9633\u6027\u5b54\u7684\u5206\u5e03\u548c\u6570\u76ee\uff0c\u5e76\u8ba1\u7b97\u6837\u672c\u5bf9\u5e94\u68c0\u6d4b\u9776\u6807\u7684\u62f7\u8d1d\u6570\u6d53\u5ea6\u3002<\/p>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u91cd\u590d\u6027\u5b9e\u9a8c\u7ed3\u679c<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u672c\u5b9e\u9a8c\u4e2d\uff0c\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf(GMO%)=(\u5916\u6e90\u57fa\u56e0\u62f7\u8d1d\u6570\u6d53\u5ea6\/\u5185\u6e90\u57fa\u56e0\u62f7\u8d1d\u6570\u6d53\u5ea6)x100%[3]\u3002\u91c7\u7528DBN9936\u3001DBN9858 GMO%\u57283%\u30011%\u6c34\u5e73\u7684\u6837\u672c\u5206\u522b\u8fdb\u884c12\u6b21\u91cd\u590d\u68c0\u6d4b\uff0c\u68c0\u6d4b\u7ed3\u679c\u5982\u88682\u6240\u793a\uff0cGMO%\u5b9e\u9645\u6d4b\u91cf\u503c\u5206\u522b\u4e3a3.64%\u30011.21%\uff0c\u7b26\u5408\u9884\u671f\uff0c\u8868\u660eQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5b9a\u91cf\u68c0\u6d4b\u51c6\u786e\u6027\u597d\u3002\u7edf\u8ba1\u5206\u679012\u6b21\u91cd\u590d\u68c0\u6d4b\u7ed3\u679c\u7684\u76f8\u5bf9\u6807\u51c6\u504f\u5dee(relative standard deviation; RSD)\u5747\u5c0f\u4e8e3.26%\uff0c\u8fdc\u5c0f\u4e8e\u6b27\u76df\u8f6c\u57fa\u56e0\u68c0\u6d4b\u7f51\u7edc\u5b9e\u9a8c\u5ba4(European Network of GMO Laboratories\uff0cENGL)\u5728\u6587\u4ef6\u4e2d\u8981\u6c42\u7684\u68c0\u6d4b\u65b9\u6cd5\u76f8\u5bf9\u6807\u51c6\u504f\u5dee\u4e0d\u8d85\u8fc725%[3]\uff0c\u8868\u660eQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5b9a\u91cf\u68c0\u6d4b\u91cd\u590d\u6027\u975e\u5e38\u597d\u3002\u56fe3\u4e3a\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf1%\u6c34\u5e73\u7684\u6837\u672c\u6570\u5b57PCR\u68c0\u6d4b\u7ed3\u679c\u793a\u4f8b\uff0c\u9634\u9633\u6027\u53cd\u5e94\u5fae\u5b54\u5206\u7fa4\u660e\u663e\uff0c\u9634\u6027\u5bf9\u7167NTC\u65e0\u9633\u6027\u5fae\u5b54\u3002<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 980px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/repeatability_results-8.png\" alt=\"\u91cd\u590d\u6027\u5b9e\u9a8c\u7ed3\u679c\u56fe\u8868\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u88682\u4e0e\u56fe3. \u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf3%\u30011%\u6c34\u5e73\u7684\u91cd\u590d\u6027\u5b9e\u9a8c\u7ed3\u679c\u4e0e1%\u6c34\u5e73\u6570\u5b57PCR\u68c0\u6d4b\u7ed3\u679c\u793a\u4f8b<\/figcaption>\n<\/figure>\n<h3 style=\"margin: 0 0 10px;font-size: 18px;color: #12305f\">\u518d\u73b0\u6027\u5b9e\u9a8c\u7ed3\u679c\u4e0e\u5b9a\u91cf\u9650\u7ed3\u679c<\/h3>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u672c\u5b9e\u9a8c\u9488\u5bf9DBN9936\u3001DBN9858\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf1%\u30010.1%\u30010.05%\u7684\u6837\u672c\u4f7f\u7528\u76f8\u540c\u4eea\u5668\u3001\u8bd5\u5242\uff0c\u4e0d\u540c\u64cd\u4f5c\u4eba\u5458\u5206\u522b\u8fdb\u884c\u91cd\u590d\u6027\u5b9e\u9a8c\uff0c\u8bc4\u4f30\u4eea\u5668\u5bf9\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u7684\u518d\u73b0\u6027\u3002\u5177\u4f53\u5b9e\u9a8c\u7ed3\u679c\u5982\u88683\u6240\u793a\u3002DBN9936\u548cDBN9858\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf1%\u6c34\u5e73\u7684\u6837\u672c\u6bcf\u6b21\u68c0\u6d4b12\u4e2a\u590d\u5b54\uff0c\u91cd\u590d\u4e24\u6b21\u5b9e\u9a8c\uff0c\u4e24\u6b21\u5b9e\u9a8c\u7ed3\u679c\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u76f8\u5bf9\u6807\u51c6\u504f\u5deeRSD\u5747\u5c0f\u4e8e5%\uff1bDBN9936\u548cDBN9858\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf0.1%\u548c0.05%\u6c34\u5e73\u7684\u6837\u672c\u6bcf\u6b21\u68c0\u6d4b6\u4e2a\u590d\u5b54\uff0c\u91cd\u590d\u4e24\u6b21\u5b9e\u9a8c\uff0c\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u76f8\u5bf9\u6807\u51c6\u504f\u5dee\u5747\u5c0f\u4e8e13.83%\uff0c\u68c0\u6d4b\u7ed3\u679c\u7b26\u5408\u6b27\u76df\u8f6c\u57fa\u56e0\u68c0\u6d4b\u6807\u51c6\u3002DBN9936\u548cDBN9858\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf1%\u30010.1%\u548c0.05%\u6c34\u5e73\u4e24\u6b21\u5b9e\u9a8c\u6279\u6b21\u95f4\u5b9a\u91cf\u7ed3\u679c\u4e00\u81f4\u6027\u9ad8\uff0c\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u76f8\u5bf9\u6807\u51c6\u504f\u5dee\u5747\u5c0f\u4e8e25%\uff0c\u8868\u660eQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5b9a\u91cf\u68c0\u6d4b\u518d\u73b0\u6027\u597d\u3002<\/p>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u5b9a\u91cf\u9650\u662f\u80fd\u591f\u51c6\u786e\u5b9a\u91cf\u7684\u6700\u4f4e\u6d53\u5ea6\u6c34\u5e73\uff0c\u901a\u8fc7DBN9936\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf0.01%\u6c34\u5e73\u7684\u6837\u672c\u8fdb\u884c12\u6b21\u91cd\u590d\u68c0\u6d4b\uff0c\u68c0\u6d4b\u7ed3\u679c\u5982\u88684\u6240\u793a\u3002DBN9936\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf0.01%\u6c34\u5e73\u7684\u6837\u672c\u5916\u6e90\u57fa\u56e0\u62f7\u8d1d\u6570\u6d53\u5ea6\u5747\u503c\u4e3a2.19 copies\/\u00b5L\uff0c\u76f8\u5bf9\u6807\u51c6\u504f\u5deeRSD\u4e3a17.77%\uff1bzSSIIb\u5185\u6e90\u57fa\u56e0\u62f7\u8d1d\u6570\u6d53\u5ea6\u5747\u503c\u4e3a14226.52 copies\/\u00b5L\uff0c\u76f8\u5bf9\u6807\u51c6\u504f\u5deeRSD\u4e3a3.83%\uff1b12\u6b21\u91cd\u590d\u68c0\u6d4b\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u5b9e\u9645\u68c0\u6d4b\u5747\u503c\u4e3a0.015%\uff0c\u68c0\u6d4b\u7ed3\u679c\u7b26\u5408\u9884\u671f\u6d53\u5ea6\u6c34\u5e73\uff0c\u8bf4\u660e\u5b9a\u91cf\u68c0\u6d4b\u7ed3\u679c\u51c6\u786e\u300212\u6b21\u91cd\u590d\u68c0\u6d4b\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u68c0\u6d4b\u7ed3\u679c\u7684\u76f8\u5bf9\u6807\u51c6\u504f\u5deeRSD\u4e3a20.18%\uff0c\u7b26\u5408\u6b27\u76df\u8f6c\u57fa\u56e0\u68c0\u6d4b\u8981\u6c42\uff0c\u8868\u660eQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5bf9\u4e8e\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u68c0\u6d4b\u7684\u5b9a\u91cf\u9650\u53ef\u4ee5\u8fbe\u52300.01%\u6c34\u5e73\u3002<\/p>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 980px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/loq_results-8.png\" alt=\"\u518d\u73b0\u6027\u4e0e\u5b9a\u91cf\u9650\u7ed3\u679c\u8868\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">\u88683\u4e0e\u88684. \u518d\u73b0\u6027\u5b9e\u9a8c\u7ed3\u679c\u4e0e0.01%\u6c34\u5e73\u5b9a\u91cf\u9650\u5b9e\u9a8c\u7ed3\u679c<\/figcaption>\n<\/figure>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u7ed3\u8bba<\/h2>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u4f20\u7edf\u8367\u5149\u5b9a\u91cfPCR\u80fd\u591f\u8fdb\u884c\u8f6c\u57fa\u56e0\u6210\u5206\u7684\u5b9a\u6027\u548c\u5b9a\u91cf\uff0c\u4f46\u5176\u4e0d\u8db3\u4e5f\u8f83\u4e3a\u660e\u663e\uff1aDNA\u6837\u54c1\u9700\u8981\u8f83\u9ad8\u7684\u54c1\u8d28\u8981\u6c42\uff0c\u5b9a\u91cf\u7ed3\u679c\u8981\u6c42PCR\u53cd\u5e94\u7684\u6548\u7387\u63a5\u8fd1100%\uff0c\u6807\u51c6\u54c1\u4ef7\u683c\u8f83\u8d35\uff0c\u7edd\u5bf9\u5b9a\u91cf\u6807\u51c6\u66f2\u7ebf\u7684\u5b9e\u9a8c\u8f83\u7e41\u7410\uff0c\u4e14\u5bf9\u4e8e\u4f4e\u6d53\u5ea6\u7684GMO\u6df7\u6742\u6837\u54c1\u68c0\u6d4b\u7075\u654f\u5ea6\u4e0d\u9ad8\u3002\u800c\u6570\u5b57PCR\u5df2\u88ab\u8bc1\u5b9e\u5bf9DNA\u6837\u54c1\u4e2d\u7684PCR\u6291\u5236\u7269\u4e0d\u654f\u611f\uff0c\u800c\u4e14\u5bf9\u4e8e\u4f4e\u6d53\u5ea6\u7684\u6837\u54c1\u5b9a\u91cf\u4e5f\u975e\u5e38\u51c6\u786e\u3002<\/p>\n<p style=\"margin: 0 0 14px;line-height: 1.9;color: #344054\">\u672c\u5b9e\u9a8cDBN9936\u548cDBN9858\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u57283%\u30011%\u30010.1%\u30010.05%\u6c34\u5e73\u7684\u6837\u672c\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u5b9e\u9645\u5b9a\u91cf\u503c\u4e0e\u9884\u671f\u6c34\u5e73\u57fa\u672c\u4e00\u81f4\uff0c\u5e76\u4e14\u5bf9\u5e94\u7684\u76f8\u5bf9\u6807\u51c6\u504f\u5deeRSD\u8fdc\u5c0f\u4e8e25%\uff0c\u7b26\u5408\u6b27\u76df\u8f6c\u57fa\u56e0\u68c0\u6d4b\u6807\u51c6\uff0c\u8868\u660eQuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5b9a\u91cf\u68c0\u6d4b\u7ed3\u679c\u51c6\u786e\u5ea6\u9ad8\u3001\u91cd\u590d\u6027\u597d\u3002QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5bf9\u4e8e\u8f6c\u57fa\u56e0\u6210\u5206\u542b\u91cf\u68c0\u6d4b\u7684\u5b9a\u91cf\u9650\u53ef\u4ee5\u8fbe\u5230\u4e07\u5206\u4e4b\u4e00\u6c34\u5e73\uff0c\u8fd9\u5c06\u4f7f\u5f97\u6570\u5b57PCR\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u53ca\u5b9a\u6027\u68c0\u6d4b\u9886\u57df\u5177\u6709\u5f88\u9ad8\u7684\u5b9e\u9645\u5e94\u7528\u4ef7\u503c\u3002<\/p>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u6587\u4e2d\u6d89\u53ca\u4ea7\u54c1<\/h2>\n<figure style=\"margin: 20px auto;border: 1px solid #e7e2d9;border-radius: 18px;padding: 12px;background: #fff;max-width: 920px\"><img decoding=\"async\" style=\"max-width: 100%;width: auto;height: auto;margin: 0 auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/products_table-8.png\" alt=\"\u6587\u4e2d\u6d89\u53ca\u4ea7\u54c1\u8868\" \/>\n<figcaption style=\"margin-top: 10px;text-align: center;color: #667085;font-size: 13px;line-height: 1.7\">Applied Biosystems QuantStudio Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u76f8\u5173\u4ea7\u54c1<\/figcaption>\n<\/figure>\n<\/section>\n<section style=\"background: #fffdfa;border: 1px solid #e6dcc8;border-radius: 22px;padding: 28px;margin-bottom: 18px\">\n<h2 style=\"margin: 0 0 12px;font-size: 24px;line-height: 1.3;color: #12305f\">\u53c2\u8003\u6587\u732e<\/h2>\n<ol style=\"margin: 0;padding-left: 20px;line-height: 1.9;color: #344054\">\n<li>\u6e38\u82f1\u534e, \u8d75\u5fd7, \u674e\u4e9a\u6960, \u5b8b\u6cbb\u56fd, \u5e38\u6d2a\u96f7, \u7b49. \u6570\u5b57PCR\u5728\u8f6c\u57fa\u56e0\u690d\u7269\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528[J]. \u4e2d\u56fd\u751f\u7269\u9632\u6cbb\u5b66\u62a5, 2022, 38(5):1143-1148.<\/li>\n<li>\u65af\u80fd\u6b66, \u674e\u4fca, \u6b66\u7389\u82b1, \u5434\u521a, \u5f20\u4e3d, \u7b49. \u6570\u5b57PCR\u5728\u8f6c\u57fa\u56e0\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u7814\u7a76\u8fdb\u5c55[J]. \u4e2d\u56fd\u6cb9\u6599\u4f5c\u7269\u5b66\u62a5, 2021, 43(1):40-50.<\/li>\n<li>Hougs L, Gatto F, Goerlich O, et al. Verification of analytical methods for GMO testing when implementing interlaboratory validated methods. EUR 29015 EN, Publication Office of the European Union, Luxembourg, 2017. DOI: 10.2788\/87679.<\/li>\n<\/ol>\n<\/section>\n<\/div>\n<\/div>\n<div style=\"margin: 18px auto 22px;max-width: 920px\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\" target=\"_blank\" rel=\"noopener noreferrer\" data-wplink-edit=\"true\"><img decoding=\"async\" style=\"width: 100%;height: auto;border-radius: 12px\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/admin-ajax-1.jpg\" alt=\"??????????????\" \/><\/a><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002<\/p>\n","protected":false},"author":1847,"featured_media":1543,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[113,37,112,115,114],"division":[9],"class_list":["post-1330","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-absolute-q","tag-digital-pcr","tag-gmo-detection","tag-pcr","tag-114","division-bid","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-26T03:35:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:26+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png\" \/>\n\t<meta property=\"og:image:width\" content=\"893\" \/>\n\t<meta property=\"og:image:height\" content=\"725\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Lisa Yao\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lisa Yao\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification\\\/\"},\"author\":{\"name\":\"Lisa Yao\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/2a226dc780a03113f4084c767a01a0d7\"},\"headline\":\"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\",\"datePublished\":\"2026-03-26T03:35:45+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification\\\/\"},\"wordCount\":235,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/hero_corn-16.png\",\"keywords\":[\"Absolute Q\",\"digital PCR\",\"GMO detection\",\"\u6570\u5b57PCR\",\"\u8f6c\u57fa\u56e0\u68c0\u6d4b\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification\",\"name\":\"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/hero_corn-16.png\",\"datePublished\":\"2026-03-26T03:35:45+00:00\",\"dateModified\":\"2026-04-22T21:59:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/2a226dc780a03113f4084c767a01a0d7\"},\"description\":\"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/hero_corn-16.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/hero_corn-16.png\",\"width\":893,\"height\":725,\"caption\":\"\u539f\u59cb\u5e94\u7528\u8bf4\u660e\u5c01\u9762\u4e3b\u89c6\u89c9\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/absolute-q-digital-pcr-gmo-quantification#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/2a226dc780a03113f4084c767a01a0d7\",\"name\":\"Lisa Yao\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g\",\"caption\":\"Lisa Yao\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lisa-yaothermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification","og_locale":"zh_CN","og_type":"article","og_title":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528","og_description":"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-26T03:35:45+00:00","article_modified_time":"2026-04-22T21:59:26+00:00","og_image":[{"width":893,"height":725,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png","type":"image\/png"}],"author":"Lisa Yao","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Lisa Yao","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\/"},"author":{"name":"Lisa Yao","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/2a226dc780a03113f4084c767a01a0d7"},"headline":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528","datePublished":"2026-03-26T03:35:45+00:00","dateModified":"2026-04-22T21:59:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\/"},"wordCount":235,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png","keywords":["Absolute Q","digital PCR","GMO detection","\u6570\u5b57PCR","\u8f6c\u57fa\u56e0\u68c0\u6d4b"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification","name":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png","datePublished":"2026-03-26T03:35:45+00:00","dateModified":"2026-04-22T21:59:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/2a226dc780a03113f4084c767a01a0d7"},"description":"\u672c\u6587\u4ecb\u7ecd Applied Biosystems QuantStudio Absolute Q \u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528\uff0c\u6db5\u76d6\u68c0\u6d4b\u539f\u7406\u3001\u5b9e\u9a8c\u6d41\u7a0b\u3001\u91cd\u590d\u6027\u3001\u518d\u73b0\u6027\u548c\u5b9a\u91cf\u9650\u7ed3\u679c\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png","width":893,"height":725,"caption":"\u539f\u59cb\u5e94\u7528\u8bf4\u660e\u5c01\u9762\u4e3b\u89c6\u89c9"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/absolute-q-digital-pcr-gmo-quantification#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"Absolute Q\u6570\u5b57PCR\u7cfb\u7edf\u5728\u8f6c\u57fa\u56e0\u6210\u5206\u5b9a\u91cf\u68c0\u6d4b\u4e2d\u7684\u5e94\u7528"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/2a226dc780a03113f4084c767a01a0d7","name":"Lisa Yao","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f20dc580325aee215108ae25169561ebee882de7e3c5c451e5de05ae86002118?s=96&d=mm&r=g","caption":"Lisa Yao"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lisa-yaothermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":113,"label":"Absolute Q"},{"value":37,"label":"digital PCR"},{"value":112,"label":"GMO detection"},{"value":115,"label":"\u6570\u5b57PCR"},{"value":114,"label":"\u8f6c\u57fa\u56e0\u68c0\u6d4b"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/hero_corn-16.png",760,617,false],"author_info":{"display_name":"Lisa Yao","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lisa-yaothermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":113,"name":"Absolute Q","slug":"absolute-q","term_group":0,"term_taxonomy_id":113,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":37,"name":"digital PCR","slug":"digital-pcr","term_group":0,"term_taxonomy_id":37,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":112,"name":"GMO detection","slug":"gmo-detection","term_group":0,"term_taxonomy_id":112,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":115,"name":"\u6570\u5b57PCR","slug":"%e6%95%b0%e5%ad%97pcr","term_group":0,"term_taxonomy_id":115,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":114,"name":"\u8f6c\u57fa\u56e0\u68c0\u6d4b","slug":"%e8%bd%ac%e5%9f%ba%e5%9b%a0%e6%a3%80%e6%b5%8b","term_group":0,"term_taxonomy_id":114,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1330","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1847"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1330"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1330\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1543"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1330"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1330"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1330"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}