{"id":1432,"date":"2026-03-31T02:28:35","date_gmt":"2026-03-31T02:28:35","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1432"},"modified":"2026-04-22T21:59:24","modified_gmt":"2026-04-22T21:59:24","slug":"rna-storage-solution","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/rna-storage-solution\/","title":{"rendered":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5728RNA\u7814\u7a76\u4e2d\uff0c\u63d0\u53d6\u540e\u7684RNA\u5982\u4f55\u957f\u671f\u4fdd\u6301\u7a33\u5b9a\u662f\u5b9e\u9a8c\u6210\u529f\u7684\u5173\u952e\u3002Invitrogen\u2122 RNA\u50a8\u5b58\u6eb6\u6db2\u51ed\u501f\u5176<strong>\u4f4epH\u503c\u548c\u67e0\u6aac\u9178\u94a0\u7f13\u51b2\u4f53\u7cfb\uff0c\u663e\u8457\u51cf\u5c11RNA\u7684\u78b1\u6c34\u89e3<\/strong>\uff0c\u6210\u4e3a\u79d1\u7814\u5de5\u4f5c\u8005\u7684\u9996\u9009\u3002\u4eca\u5929\uff0c\u8ba9\u6211\u4eec\u4e00\u8d77\u63a2\u7d22RNA\u50a8\u5b58\u6eb6\u6db2\u5728\u591a\u4e2a\u70ed\u95e8\u7814\u7a76\u9886\u57df\u7684\u5353\u8d8a\u8868\u73b0\uff01<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-mrna\u75ab\u82d7\u5f00\u53d1-\u7a33\u5b9a\u50a8\u5b58-\u52a9\u529b\u9ad8\u6548\u9012\u9001\"><strong>mRNA\u75ab\u82d7\u5f00\u53d1\uff1a\u7a33\u5b9a\u50a8\u5b58\uff0c\u52a9\u529b\u9ad8\u6548\u9012\u9001<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8102\u8d28\u7eb3\u7c73\u9897\u7c92\uff08LNP\uff09\u662fmRNA\u75ab\u82d7\u9012\u9001\u7684\u6838\u5fc3\u6280\u672f\u3002\u7814\u7a76\u8868\u660e\uff0c\u5728mRNA\u75ab\u82d7\u5236\u5907\u8fc7\u7a0b\u4e2d\uff0c\u8f6c\u5f55\u540e\u7684mRNA\u9700\u5728\u7a33\u5b9a\u6eb6\u6db2\u4e2d\u4fdd\u5b58\u4ee5\u786e\u4fdd\u5b8c\u6574\u6027\u3002RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176<strong>\u4f4epH\u7f13\u51b2\u4f53\u7cfb\u548c\u9ad8\u6548\u87af\u5408\u80fd\u529b<\/strong>\uff0c\u4e3amRNA\u63d0\u4f9b\u957f\u671f\u7a33\u5b9a\u7684\u50a8\u5b58\u73af\u5883\uff0c\u663e\u8457\u63d0\u5347LNP\u5305\u5c01\u6548\u7387\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Saraswat\u7b49\u7814\u7a76\u8005\u4f7f\u7528<strong>RNA\u50a8\u5b58\u6eb6\u6db2<\/strong>\u4fdd\u5b58SARS-CoV-2 mRNA\u75ab\u82d7\u7684\u8f6c\u5f55\u4ea7\u7269\uff0c\u901a\u8fc7Qubit\u5b9a\u91cf\u548c\u751f\u7269\u5206\u6790\u4eea\u68c0\u6d4b\uff0c\u8bc1\u5b9emRNA\u5b8c\u6574\u6027\uff0c\u4e3a\u75ab\u82d7\u7684\u514d\u75ab\u539f\u6027\u548c\u7a33\u5b9a\u6027\u5960\u5b9a\u57fa\u7840<sup>[1]<\/sup>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"729\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x-1024x729.png\" alt=\"\" class=\"wp-image-1433\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x-1024x729.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x-300x214.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x-768x547.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png 1084w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe1 LNPssPalmE-Phe\u5236\u5907\u793a\u610f\u56fe\uff0c\u901a\u8fc7\u5fae\u6d41\u63a7\u6df7\u5408\u5236\u5907\u7a7aLNPs\uff0c\u51bb\u5e72\u5f97\u5230\u5e72\u71e5\u7684\u7a7aLNPs\uff0c\u5c06\u5e72\u71e5\u7684LNPs\u4e0emRNA\u6eb6\u6db2\u5728\u6c34\u4e2d\u91cd\u7ec4\u5f97\u5230mRNA\u5305\u5c01LNPs<sup>[1]<\/sup>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-t\u7ec6\u80de\u514d\u75ab\u7597\u6cd5-\u7cbe\u51c6\u9012\u9001-\u63a8\u52a8\u7ec6\u80de\u6cbb\u7597\"><strong><br>T\u7ec6\u80de\u514d\u75ab\u7597\u6cd5\uff1a\u7cbe\u51c6\u9012\u9001\uff0c\u63a8\u52a8\u7ec6\u80de\u6cbb\u7597<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">mRNA\u6280\u672f\u5728T\u7ec6\u80de\u514d\u75ab\u7597\u6cd5\u4e2d\u5c55\u73b0\u51fa\u5de8\u5927\u6f5c\u529b\u3002\u901a\u8fc7\u4f53\u5916\u8f6c\u5f55\u5408\u6210\u7684mRNA\u9700\u5728\u65e0RNase\u73af\u5883\u4e2d\u4fdd\u5b58\uff0c\u4ee5\u786e\u4fdd\u5176\u7ffb\u8bd1\u6548\u7387\u3002<strong>RNA\u50a8\u5b58\u6eb6\u6db2<\/strong>\u7684\u4f4epH\u7f13\u51b2\u6db2\u548c\u67e0\u6aac\u9178\u94a0\u914d\u65b9\u6709\u6548\u9632\u6b62RNA\u964d\u89e3\uff0c\u4e3a\u6297\u539f\u63d0\u5448\u7eb3\u7c73\u9897\u7c92\uff08APNs\uff09\u7684mRNA\u9012\u9001\u63d0\u4f9b\u53ef\u9760\u652f\u6301\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fang-Yi Su\u7b49\u7814\u7a76\u8005\u91c7\u7528RNA\u50a8\u5b58\u6eb6\u6db2\u4fdd\u5b58\u4fc3\u51cb\u4ea1\u86cb\u767dmRNA\uff0c\u7ecfNanodrop\u5b9a\u91cf\u548c\u51dd\u80f6\u7535\u6cf3\u9a8c\u8bc1\uff0cmRNA\u6d53\u5ea6\u548c\u5b8c\u6574\u6027\u5747\u6ee1\u8db3\u6cbb\u7597\u9700\u6c42\uff0c\u6210\u529f\u5b9e\u73b0T\u7ec6\u80de\u7684\u7cbe\u51c6\u6539\u9020<sup>[2]<\/sup>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"524\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220405@2x-1024x524.png\" alt=\"\" class=\"wp-image-1434\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220405@2x-1024x524.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220405@2x-300x154.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220405@2x-768x393.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220405@2x.png 1098w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe2 \u6297\u539f\u63d0\u5448\u7eb3\u7c73\u9897\u7c92\u4ee5TCR\u4f9d\u8d56\u7684\u65b9\u5f0f\u8f6c\u67d3\u6297\u539f\u7279\u5f02\u6027T\u7ec6\u80de<sup>[2]<\/sup>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-rt-qpcr\u68c0\u6d4b-\u9ad8\u7075\u654f\u5ea6-\u4fdd\u969c\u6570\u636e\u51c6\u786e\u6027\"><strong>RT-qPCR\u68c0\u6d4b\uff1a\u9ad8\u7075\u654f\u5ea6\uff0c\u4fdd\u969c\u6570\u636e\u51c6\u786e\u6027<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"541\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220446@2x-1024x541.png\" alt=\"\" class=\"wp-image-1435\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220446@2x-1024x541.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220446@2x-300x158.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220446@2x-768x405.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220446@2x.png 1072w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Note\uff1a\u7eaf\u8fd0\u52a8\u7ec4\uff08EX\uff09\u548c\u8fd0\u52a8+\u70ed\u817f\u7ec4\uff08EX + HT\uff09\u4e2d\uff0c\u8fd0\u52a8\u540e\u7acb\u5373\uff08Post\uff09\u548c\u8fd0\u52a8\u540e4\u5c0f\u65f6\uff084hPost\uff09<sup>[3]<\/sup>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5bc4\u751f\u866b\u57fa\u56e0\u7814\u7a76-\u7a33\u5b9a\u4fdd\u5b58-\u652f\u6301\u957f\u671f\u5206\u6790\"><strong>\u5bc4\u751f\u866b\u57fa\u56e0\u7814\u7a76\uff1a\u7a33\u5b9a\u4fdd\u5b58\uff0c\u652f\u6301\u957f\u671f\u5206\u6790<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u5df4\u8d1d\u65af\u866b\u8010\u836f\u6027\u7814\u7a76\u4e2d\uff0c\u7ebf\u7c92\u4f53\u57fa\u56e0RNA\u7684\u957f\u671f\u4fdd\u5b58\u81f3\u5173\u91cd\u8981\u3002<strong>RNA\u50a8\u5b58\u6eb6\u6db2<\/strong>\u7684\u9ad8\u6548\u7a33\u5b9a\u6027\u4f7f\u5176\u6210\u4e3a\u5bc4\u751f\u866bRNA\u7814\u7a76\u7684\u7406\u60f3\u9009\u62e9\uff0c\u5373\u4f7f\u5728-80\u2103\u957f\u671f\u50a8\u5b58\u540e\u4ecd\u80fd\u4fdd\u6301RNA\u5b8c\u6574\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eba\u7c7b\u5df4\u8d1d\u65af\u866b\u75c5\u662f\u7531\u5df4\u8d1d\u65af\u866b\u5bc4\u751f\u866b\u5728\u7ea2\u7ec6\u80de\u4e2d\u53d1\u80b2\u540e\u5f15\u8d77\u7684\u4e00\u79cd\u65b0\u51fa\u73b0\u7684\u8731\u4f20\u759f\u75be\u6837\u75be\u75c5\u3002Joy E Chiu\u5229\u7528TRIzol \uff08Invitrogen\uff09\u63d0\u53d6\u5df4\u8d1d\u65af\u866bCytb\u57fa\u56e0RNA\uff0c\u7528RNA\u50a8\u5b58\u6eb6\u6db2\u4fdd\u5b58\uff0c\u6210\u529f\u5b8c\u6210PCR\u6269\u589e\u548c\u6d4b\u5e8f\uff0c\u4e3a\u8010\u836f\u673a\u5236\u7814\u7a76\u63d0\u4f9b\u5173\u952e\u6570\u636e<sup>[4]<\/sup>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"360\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220521@2x-1024x360.png\" alt=\"\" class=\"wp-image-1436\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220521@2x-1024x360.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220521@2x-300x105.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220521@2x-768x270.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220521@2x.png 1082w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe3 &nbsp;ELQ-502\u5df4\u8d1d\u65af\u866b\u7684\u8010\u836f\u9274\u5b9a\u3002\uff08A\uff09 BmCytb\u7684\u4e09\u7ef4\u7ed3\u6784\u9884\u6d4b\u3002\uff08B\uff09\u4e24\u7ec4\u6bcf\u7ec43\u53ea\u5c0f\u9f20\u611f\u67d3\u5df4\u8d1d\u65af\u866b\uff0c\u4ece\u611f\u67d3\u540e\u7b2c3\u5929\u5f00\u59cb\uff0c\u5206\u522b\u7ed9\u836f\uff08PEG-400\uff09\u6216ELQ-502 \uff0810 mg\/kg\uff09\u6cbb\u75975\u5929\uff0c\u53bb\u9664\u836f\u7269\u540e17\u5929\u68c0\u51fa\u8010\u836f\u5bc4\u751f\u866b<sup>[4]<\/sup>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ea7\u54c1\u4f18\u52bf\"><strong>\u4ea7\u54c1\u4f18\u52bf<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Invitrogen\u2122 RNA \u50a8\u5b58\u6eb6\u6db2<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4f4e pH \u548c\u67e0\u6aac\u9178\u94a0\u51cf\u5c11RNA \u7684\u78b1\u6c34\u89e3<\/li>\n\n\n\n<li>1 mM \u67e0\u6aac\u9178\u94a0\u3001pH 6.5 \u00b1 0.1 \u7f13\u51b2\u6db2<\/li>\n\n\n\n<li>\u9ad8\u6548\u7684\u87af\u5408\u5242<\/li>\n\n\n\n<li>RNA \u7a33\u5b9a\u6027\u5f3a<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"429\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220600@2x-1024x429.png\" alt=\"\" class=\"wp-image-1437\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220600@2x-1024x429.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220600@2x-300x126.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220600@2x-768x321.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220600@2x.png 1104w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u6587\u732e\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">[1] Saraswat A, Nomani A, Yong L K, et al. A Polysorbate-Based Lipid Nanoparticle Vaccine Formulation Induces In Vivo Immune Response Against SARS-CoV-2[J]. Pharmaceutics, 2025, 17(4): 441.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] Su F Y, Siebart J C, Chan C S, et al. Antigen-specific T cell immunotherapy by in vivo mRNA delivery[J]. bioRxiv, 2024.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3] McGlynn M L, Rosales A M, Collins C W, et al. The combined influences of local heat application and resistance exercise on the acute mRNA response of skeletal muscle[J]. Frontiers in Physiology, 2024, 15: 1473241.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[4] Chiu J E, Renard I, George S, et al. Cytochrome b drug resistance mutation decreases babesia fitness in the tick stages but not the mammalian erythrocytic cycle[J]. The Journal of Infectious Diseases, 2022, 225(1): 135-145.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5728RNA\u7814\u7a76\u4e2d\uff0c\u63d0\u53d6\u540e\u7684RNA\u5982\u4f55\u957f\u671f\u4fdd\u6301\u7a33\u5b9a\u662f\u5b9e\u9a8c\u6210\u529f\u7684\u5173\u952e\u3002Invitrogen\u2122 RNA\u50a8\u5b58\u6eb6\u6db2\u51ed\u501f\u5176\u4f4e<\/p>\n","protected":false},"author":1852,"featured_media":1433,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[],"division":[9],"class_list":["post-1432","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834\" \/>\n<meta property=\"og:description\" content=\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-31T02:28:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:24+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1084\" \/>\n\t<meta property=\"og:image:height\" content=\"772\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834\",\"datePublished\":\"2026-03-31T02:28:35+00:00\",\"dateModified\":\"2026-04-22T21:59:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/\"},\"wordCount\":204,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-220328@2x.png\",\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/\",\"name\":\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-220328@2x.png\",\"datePublished\":\"2026-03-31T02:28:35+00:00\",\"dateModified\":\"2026-04-22T21:59:24+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-220328@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-220328@2x.png\",\"width\":1084,\"height\":772},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/rna-storage-solution\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/","og_locale":"zh_CN","og_type":"article","og_title":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834","og_description":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-31T02:28:35+00:00","article_modified_time":"2026-04-22T21:59:24+00:00","og_image":[{"width":1084,"height":772,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/rna-storage-solution\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834","datePublished":"2026-03-31T02:28:35+00:00","dateModified":"2026-04-22T21:59:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/rna-storage-solution\/"},"wordCount":204,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png","articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/rna-storage-solution\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/","name":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png","datePublished":"2026-03-31T02:28:35+00:00","dateModified":"2026-04-22T21:59:24+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\u4ee5\u5176\u5353\u8d8a\u7684\u7a33\u5b9a\u6027\u548c\u5e7f\u6cdb\u7684\u5e94\u7528\u573a\u666f\uff0c\u6210\u4e3aRNA\u7814\u7a76\u4e2d\u7684\u9996\u9009\u3002\u65e0\u8bba\u662f\u75ab\u82d7\u5f00\u53d1\u3001\u7ec6\u80de\u6cbb\u7597\uff0c\u8fd8\u662f\u57fa\u56e0\u8868\u8fbe\u5206\u6790\uff0c\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u4fdd\u9a7e\u62a4\u822a\uff01","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x.png","width":1084,"height":772},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/rna-storage-solution\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"Invitrogen RNA\u50a8\u5b58\u6eb6\u6db2\uff1a\u9ad8\u6548\u7a33\u5b9a\uff0c\u8d4b\u80fdRNA\u7814\u7a76\u65b0\u7a81\u7834"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-220328@2x-1024x729.png",760,541,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":2,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1432"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1432\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1433"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1432"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}