{"id":1444,"date":"2026-04-10T03:34:56","date_gmt":"2026-04-10T03:34:56","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1444"},"modified":"2026-04-22T21:59:22","modified_gmt":"2026-04-22T21:59:22","slug":"attune-xenith-technotes","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/","title":{"rendered":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u514d\u75ab\u8868\u578b\u5206\u6790\u662f\u901a\u8fc7\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u8868\u9762\u6216\u5185\u90e8\u7684\u7279\u5b9a\u6297\u539f\u6807\u8bb0\u7269\uff0c\u7528\u4e8e\u75be\u75c5\u8bca\u65ad\uff08\u5c24\u5176\u662f\u8840\u6db2\u80bf\u7624\u5206\u578b\uff09\u548c\u7ec6\u80de\u529f\u80fd\u7814\u7a76\u7684\u4e00\u9879\u68c0\u6d4b\u6280\u672f\u3002\u9ad8\u7ef4\u591a\u8272\u6d41\u5f0f\u65b9\u6848\u7684\u7cbe\u51c6\u89e3\u6790\u4e3b\u8981\u53d7\u6d41\u5f0f\u7ec6\u80de\u4eea\u786c\u4ef6\u7cfb\u7edf\u7684\u6027\u80fd\u548c\u6837\u672c\u8d28\u91cf\u7684\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6240\u7528\u4eea\u5668<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Invitrogen\u2122 Attune\u2122 Xenith\u2122 \u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u5206\u6790\u4eea<\/li>\n\n\n\n<li>Invitrogen\u2122 Countess\u2122 3 FL \u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f18\u5316\u6837\u672c\u5236\u5907\u6d41\u7a0b-\u4fdd\u8bc1\u6837\u672c\u8d28\u91cf\"><strong>\u4f18\u5316\u6837\u672c\u5236\u5907\u6d41\u7a0b\uff0c\u4fdd\u8bc1\u6837\u672c\u8d28\u91cf<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u6709\u6548\u51cf\u5c11\u7ec6\u80de\u805a\u96c6\u548c\u907f\u514d\u9776\u6807\u5f02\u5e38\u8868\u8fbe\uff0c\u9700\u4ece\u6837\u672c\u91c7\u96c6\u5230\u6570\u636e\u83b7\u53d6\u5168\u6d41\u7a0b\u5b9e\u65bd\u6807\u51c6\u5316\u64cd\u4f5c\u3002\u6b7b\u7ec6\u80de\u3001\u6e38\u79bb\u788e\u7247\u53ca\u635f\u4f24\u76f8\u5173\u5206\u5b50\u6a21\u5f0f\uff08damage-associated molecular patterns, DAMPs\uff09\u90fd\u4f1a\u5e72\u6270\u4e0b\u6e38\u514d\u75ab\u8868\u578b\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6539\u8fdb\u6837\u672c\u6d88\u5316\u548c\u9176\u5904\u7406\u6b65\u9aa4\u53ef\u4ee5\u63d0\u5347\u6837\u672c\u8d28\u91cf\u3002\u7814\u7a76\u4eba\u5458\u5e94\u7cfb\u7edf\u5730\u8003\u8651\u6837\u672c\u5236\u5907\u6d41\u7a0b\u4e2d<strong>\u7ec4\u7ec7\u89e3\u79bb\u3001\u7ec6\u80de\u88c2\u89e3\u3001\u9176\u5904\u7406\u53ca\u7eaf\u5316\u6b65\u9aa4\u7684\u4f18\u5316<\/strong>\uff08\u56fe 1\uff09\u3002\u68af\u5ea6\u79bb\u5fc3\u7b49\u7ec6\u80de\u788e\u7247\u53bb\u9664\u65b9\u6cd5\u5fc5\u9700\u5e73\u8861\u6837\u672c<strong>\u5904\u7406\u65f6\u95f4<\/strong>\u3001<strong>\u6210\u672c<\/strong>\u4ee5\u53ca\u5bf9\u7ec6\u80de\u6d3b\u6027\u548c\u7ec6\u80de\u7fa4\u7684\u5f71\u54cd\u3002\u5177\u4f53\u64cd\u4f5c\u65b9\u6cd5\u5e94\u6839\u636e\u7ec4\u7ec7\u7c7b\u578b\u3001\u76ee\u6807\u7ec6\u80de\u7fa4\u53ca\u5206\u5b50\u9776\u6807\u7684\u751f\u7269\u5b66\u7279\u6027\u8fdb\u884c\u76f8\u5e94\u8c03\u6574\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"211\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221159@2x-1024x211.png\" alt=\"\" class=\"wp-image-1445\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221159@2x-1024x211.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221159@2x-300x62.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221159@2x-768x158.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221159@2x.png 1088w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe 1. \u51cf\u5c11\u7ec6\u80de\u805a\u96c6\u548cDAMPs\u7684\u63a8\u8350\u5b9e\u9a8c\u6b65\u9aa4\uff0c\u968f\u540e\u518d\u8fdb\u884c\u514d\u75ab\u8868\u578b\u67d3\u8272\u3002\u5bf9\u4e8e\u7ec4\u7ec7\u6d88\u5316\u7269\uff0c\u5c3d\u53ef\u80fd\u51cf\u5c11\u624b\u52a8\u526a\u5207\u6b21\u6570\uff0c\u6216\u662f\u907f\u514d\u8fc7\u5ea6\u5316\u5b66\u5904\u7406\u3002\u8be5\u6d41\u7a0b\u7ecf\u8bc1\u5b9e\u5904\u7406\u813e\u810f\u6837\u672c\u7684\u6548\u679c\u5f88\u597d\uff0c\u5305\u62ecDNase\u9176\u5904\u7406\u548c\u8fc7\u6ee4\u73af\u8282\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f7f\u7528\u6b7b\u6d3b\u7ec6\u80de\u67d3\u6599-\u8fdb\u884c\u6837\u672c\u8d28\u91cf\u63a7\u5236\"><strong>\u4f7f\u7528\u6b7b\u6d3b\u7ec6\u80de\u67d3\u6599\uff0c\u8fdb\u884c\u6837\u672c\u8d28\u91cf\u63a7\u5236<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u786e\u4fdd\u6837\u672c\u8d28\u91cf\uff0c\u5efa\u8bae\u5728\u6837\u672c\u5236\u5907\u4e0e\u6570\u636e\u91c7\u96c6\u9636\u6bb5\u90fd\u8fdb\u884c<strong>\u6b7b\u6d3b\u7ec6\u80de\u5206\u7fa4\u5206\u6790<\/strong>\u3002\u4f7f\u7528Countess 3 FL\u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea\uff0c\u53ef\u57282\u5206\u949f\u5185\u5feb\u901f\u8bc4\u4f30\u7ec6\u80de\u6837\u672c\uff08\u4ec5\u9700\u5c11\u91cf\u6837\u672c\uff0c\u226410 \u00b5L\uff09\u3002<strong>\u5728\u6d41\u5f0f\u5b9e\u9a8c\u65b9\u6848\u4e2d\u52a0\u5165\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\uff0c\u901a\u8fc7\u8bbe\u95e8\u53bb\u9664\u6b7b\u7ec6\u80de\uff1a<\/strong>\u8be5\u8d28\u91cf\u63a7\u5236\u6b65\u9aa4\u6781\u4e3a\u5173\u952e\uff0c\u5c24\u5176\u662f\u5bf9\u4e8e<strong>\u539f\u4ee3\u7ec4\u7ec7\u548c\u80bf\u7624\u6837\u672c<\/strong>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"788\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221239@2x-1024x788.png\" alt=\"\" class=\"wp-image-1446\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221239@2x-1024x788.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221239@2x-300x231.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221239@2x-768x591.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221239@2x.png 1084w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe2. \u5c0f\u9f20\u813e\u7ec6\u80de\u6837\u672c\u8d28\u91cf\u4e0d\u9ad8\uff0c\u4f7f\u5f97\u6d41\u5f0f\u5b9e\u9a8c\u7ed3\u679c\u4e0d\u51c6\u786e\u3002<\/strong>\u6570\u636e\u91c7\u96c6\u8fc7\u7a0b\u4e2d\u89c2\u5bdf\u5230\u7684\u7ec6\u80de\u9ecf\u8054\u4f53\/\u805a\u96c6\u4f53\u53ca\u5f88\u591a\u788e\u7247\uff08\u7ea2\u8272\u7bad\u5934\u6307\u793a\uff09\u4e3a\u7ec6\u80de\u6837\u672c\u788e\u7247\u3002\u8fd9\u4e9b\u73b0\u8c61\u8868\u660e\u6837\u672c\u6574\u4f53\u8d28\u91cf\u6709\u95ee\u9898\uff0c\u53ef\u80fd\u5bfc\u81f4\u6297\u539f\u8868\u8fbe\u5f02\u5e38\u3002\u6b64\u5916\uff0c\u4f4e\u8d28\u91cf\u7ec6\u80de\u6709\u65f6\u5f88\u96be<strong>\u901a\u8fc7\u5708\u95e8<\/strong>\uff08\u6b64\u5904\u6307\u5355\u7ec6\u80de\u95e8\u3001\u76ee\u6807\u533a\u57df(Region of interest, ROI)\u548c\u6d3b\u7ec6\u80de\u95e8\uff09\u5b8c\u5168\u6392\u9664\uff0c\u56e0\u6b64\u5bb9\u6613\u5f15\u53d1\u540e\u7eed\u5206\u6790\u8bef\u5dee\u3002LIVE\/DEAD NIR876\u4e3aInvitrogen\u2122 LIVE\/DEAD\u2122 Fixable NIR 876\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\uff08\u8d27\u53f7 L34980\uff09\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7a33\u5b9a\u5730\u6570\u636e\u91c7\u96c6\u6781\u4e3a\u91cd\u8981\"><strong>\u7a33\u5b9a\u5730\u6570\u636e\u91c7\u96c6\u6781\u4e3a\u91cd\u8981<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u8fc7<strong>\u65f6\u95f4\u53c2\u6570\u52a8\u6001\u56fe\uff08time plots\uff09<\/strong>\u8bc4\u4f30\u4e0a\u673a\u91c7\u96c6\u7684\u7a33\u5b9a\u6027\uff0c\u6709\u52a9\u4e8e\u83b7\u5f97\u53ef\u9760\u6570\u636e\u3002\u8fd9\u7c7b\u56fe\u8868\u53ef\u5728\u6837\u672c\u91c7\u96c6\u6216\u6570\u636e\u5206\u6790\u6b65\u9aa4\u4e2d\u751f\u6210\u3002\u56fe 3\u6570\u636e\u8868\u660e\uff0c\u5373\u4f7f\u5728\u6837\u672c\u8d28\u91cf\u6b20\u4f73\uff08\u5373\u56fe2\u5c0f\u9f20\u813e\u810f\u4f4e\u8d28\u91cf\u6837\u672c\uff09\u7684\u60c5\u51b5\u4e0b\uff0c\u6570\u636e\u91c7\u96c6\u8fc7\u7a0b\u4ecd\u4fdd\u6301\u9ad8\u5ea6\u7a33\u5b9a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c3d\u7ba1\u6837\u672c\u8d28\u91cf\u6b20\u4f73\uff0cAttune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u4ecd\u5c55\u73b0\u51fa<strong>\u5353\u8d8a\u7684\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027<\/strong>\uff0c\u4ece\u800c\u786e\u4fdd\u5b9e\u9a8c\u7ed3\u679c\u7684\u53ef\u9760\u6027\u4e0e\u53ef\u91cd\u590d\u6027\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"637\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x-1024x637.png\" alt=\"\" class=\"wp-image-1447\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x-1024x637.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x-300x187.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x-768x478.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x-320x200.png 320w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221411@2x.png 1096w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe3. \u901a\u8fc7\u65f6\u95f4\u53c2\u6570\u52a8\u6001\u56fe\u8bc4\u4f30\u6570\u636e\u91c7\u96c6\u7684\u8d28\u91cf\u3002<\/strong>\u5f53\u5fc5\u987b\u4f7f\u7528\u8d28\u91cf\u6b20\u4f73\u7684\u6837\u672c\u65f6\uff0c\u6570\u636e\u91c7\u96c6\u8fc7\u7a0b\u7684\u8d28\u91cf\u63a7\u5236\u5341\u5206\u91cd\u8981\u3002<strong>\u65f6\u95f4\u4e0e\u6563\u5c04\u5149\u901a\u9053\u7684\u65f6\u95f4\u53c2\u6570\u52a8\u6001\u56fe<\/strong>\u53ef\u4ee5\u6765\u68c0\u6d4b\u5404\u79cd\u5f02\u5e38\u60c5\u51b5\uff0c\u6bd4\u5982\u7ecf\u5e38\u5bb9\u6613\u53d1\u751f\u7ba1\u8def\u5835\u585e\u7684\u6837\u672c\u3002\u5728\u672c\u6848\u4f8b\u4e2d\uff0c\u8fd9\u91cc\u7528\u5230\u4e86\u7ec4\u7ec7\u6d88\u5316\u6837\u672c\uff0c\u542b\u6709\u5f88\u5c11\u7684\u6d3b\u7ec6\u80de\u3002\u540e\u7eed\u7684\u6570\u636e\u5904\u7406\u5de5\u5177\u548c\u65f6\u95f4\u76f8\u5173\u7684\u8bbe\u95e8\u7b56\u7565\u80fd\u591f\u4f18\u5316\u91c7\u96c6\u7ed3\u679c\u3002\u8fd9\u4e9b\u6837\u672c\u8868\u73b0\u51fa\u4e86\u7a33\u5b9a\u7684\u91c7\u96c6\u901f\u7387\uff0c\u8fd9\u4e9b\u65f6\u95f4\/\u6563\u5c04\u5149\u53c2\u6570\u76f8\u5173\u6d41\u5f0f\u56fe\u53ef\u4ee5\u5728\u6570\u636e\u91c7\u96c6\u6216\u5206\u6790\u6b65\u9aa4\u4e2d\u751f\u6210\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6837\u672c\u8d28\u91cf\u5bf9\u5149\u8c31\u89e3\u6790\u7ed3\u679c\u7684\u5f71\u54cd\"><strong>\u6837\u672c\u8d28\u91cf\u5bf9\u5149\u8c31\u89e3\u6790\u7ed3\u679c\u7684\u5f71\u54cd<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684<strong>\u58f0\u6ce2\u805a\u7126\u6280\u672f<\/strong>\u80fd\u591f\u6709\u6548\u5904\u7406\u5bb9\u6613\u5835\u585e\u7684\u6837\u672c\uff0c\u4f46\u9700\u6ce8\u610f\u7684\u662f\u6837\u672c\u8d28\u91cf\u4f9d\u7136\u4e25\u91cd\u5f71\u54cd\u6570\u636e\u7ed3\u679c\uff08\u56fe 4\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"514\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x-1024x514.png\" alt=\"\" class=\"wp-image-1448\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x-1024x514.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x-300x151.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x-768x385.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png 1084w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56fe4. \u6837\u672c\u8d28\u91cf\u5bf9\u86cb\u767d\u8868\u8fbe\u8c31\u7684\u5f71\u54cd\u3002<\/strong>\u4ece\u5c0f\u9f20\u9aa8\u9ad3\u4e2d\u5206\u79bbCD19+ B220+ B\u7ec6\u80de\uff0c\u6bd4\u8f83\u4e0d\u540c\u7ec6\u80de\u4e9a\u7fa4\u7684\u6d3b\u6027\u6c34\u5e73\u3002(A) \u5728\u8868\u9762\u6807\u5fd7\u7269\u67d3\u8272\u524d\uff0c\u8be5\u6837\u672c\u901a\u8fc7\u7ec6\u80de\u8ba1\u6570\u548c\u53f0\u76fc\u84dd\u62d2\u67d3\u6cd5\u663e\u793a\u6b7b\u7ec6\u80de\u6bd4\u4f8b\u8f83\u9ad8\u3002\u5728\u6d41\u5f0f\u5206\u6790\u4e2d\u8be5\u6837\u672c\u8868\u73b0\u51fa\u5f02\u5e38\u7684\u86cb\u767d\u8868\u8fbe\u8c31\u3002(B) \u76f8\u540c\u6837\u672c\u5904\u7406\u5206\u6790\u6761\u4ef6\u4e0b\uff0c\u9ad8\u6d3b\u6027\u7684\u6837\u672c\u7ec6\u80de\u8868\u73b0\u51fa\u6b63\u5e38\u86cb\u767d\u8868\u8fbe\u8c31\u3002\u56e0\u6b64\uff0c\u5373\u4f7f\u901a\u8fc7\u8bbe\u95e8\u7b56\u7565\u6765\u53bb\u9664\u788e\u7247\u548c\u6b7b\u7ec6\u80de\uff0c\u6837\u672c\u4e2d\u7684\u7ec6\u80de\u6d3b\u6027\u8d28\u91cf\u7f3a\u9677\u4ecd\u4f1a\u5bfc\u81f4\u9ad8\u7ef4\u591a\u8272\u5149\u8c31\u6570\u636e\u51fa\u73b0\u5f02\u5e38\u4fe1\u53f7\u3002Real Blue 780\u4e3aReal Blue\u2122 780\u8367\u5149\u67d3\u6599\u3002Brilliant Ultra Violet 661\u4e3aBrilliant Ultra Violet\u2122 661\u8367\u5149\u67d3\u6599\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u8bba\"><strong>\u7ed3\u8bba<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8981\u5b9e\u73b0\u6df1\u5165\u7684\u514d\u75ab\u8868\u578b\u5206\u6790\uff0c\u9700\u4e25\u683c\u628a\u63a7<strong>\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7684\u7a33\u5b9a\u6027<\/strong>\u3002Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u51ed\u501f\u5176\u5148\u8fdb\u7684\u5149\u5b66\u68c0\u6d4b\u7cfb\u7edf\u548c\u6db2\u6d41\u8bbe\u8ba1\uff0c\u5373\u4fbf\u9762\u5bf9\u590d\u6742\u6837\u672c\u4e5f\u80fd\u63d0\u4f9b\u5353\u8d8a\u8d28\u91cf\u7684\u6570\u636e\u3002\u5efa\u8bae\u63d0\u524d\u8bc4\u4f30\u6837\u672c\u8d28\u91cf\uff1a\u5728\u6837\u672c\u5236\u5907\u521d\u671f\u9636\u6bb5\uff08\u5373\u67d3\u8272\u524d\uff09\uff0c\u4f7f\u7528Countess 3 FL\u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea\u8fdb\u884c\u5feb\u901f\u7ec6\u80de\u8ba1\u6570\u548c\u6d3b\u6027\u68c0\u6d4b\uff0c\u4ee5\u907f\u514d\u8fc7\u591a\u7684\u7ec6\u80de\u788e\u7247\u6216\u6b7b\u7ec6\u80de\u7ed9\u540e\u7eed\u67d3\u8272\u548c\u5206\u6790\u5e26\u6765\u7684\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5404\u4e2a\u9636\u6bb5\uff0c\u901a\u8fc7\u5efa\u7acb<strong>\u6570\u636e\u8d28\u91cf\u68c0\u67e5\u70b9<\/strong>\u3001\u4e0d\u65ad<strong>\u4f18\u5316\u6837\u672c\u5904\u7406\u6d41\u7a0b<\/strong>\uff0c\u7814\u7a76\u4eba\u5458\u53ef\u4ee5\u5145\u5206\u53d1\u6325\u6d41\u5f0f\u7ec6\u80de\u4eea\u6027\u80fd\uff0c\u7a33\u5b9a\u83b7\u5f97\u4f18\u8d28\u7684\u6d41\u5f0f\u6570\u636e\uff0c\u4ece\u800c\u5f97\u5230\u7a33\u5b9a\u53ef\u9760\u7684\u514d\u75ab\u8868\u578b\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6240\u7528\u8bd5\u5242\u4e0e\u8017\u6750\"><strong>\u6240\u7528\u8bd5\u5242\u4e0e\u8017\u6750<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"977\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221524@2x-1024x977.png\" alt=\"\" class=\"wp-image-1449\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221524@2x-1024x977.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221524@2x-300x286.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221524@2x-768x733.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221524@2x.png 1092w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9e\u9a8c\u6b65\u9aa4\"><strong>\u5b9e\u9a8c\u6b65\u9aa4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bd5\u5242\u5236\u5907<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u6240\u6709\u8bd5\u5242\u5747\u5e94\u57284 \u2103\u4e0b\u4f7f\u7528\uff0c\u9664\u975e\u751f\u4ea7\u5546\u53e6\u6709\u8bf4\u660e\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\uff1a\u5c061\u4efdeBioscience 10\u00d7\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\u52a0\u5230 9\u4efd\u8d85\u7eaf\u6c34\u4e2d\uff0c\u5236\u5907\u88c2\u89e3\u5de5\u4f5c\u6db2\u3002\u4f7f\u7528\u524d\uff0c\u4e8e4 \u2103\u4fdd\u5b58\u3002<\/li>\n\n\n\n<li>\u7ec6\u80de\u57f9\u517b\u57fa\uff1a\u5c061\u4efd\u70ed\u706d\u6d3b\u4f18\u8d28\u80ce\u725b\u8840\u6e05\u52a0\u52309\u4efdRPMI 1640\u57f9\u517b\u57fa\u4e2d\u8fdb\u884c\u5236\u5907\u3002\u591a\u6b21\u98a0\u5012\u6df7\u5300\uff0c\u4e8e4 \u2103\u4e0b\u4f7f\u7528\u3002<\/li>\n\n\n\n<li>DNase\u5de5\u4f5c\u6db2\uff1aa. \u5c06\u51bb\u5e72DNase I\u6eb6\u89e3\u4e8e\u8d85\u7eaf\u6c34\u4e2d\uff0c\u914d\u5236\u62105 mg\/mL\u7684\u50a8\u5b58\u6db2\u3002\u6309\u7167\u5382\u5bb6\u8bf4\u660e\u4e66\u5c06\u5176\u5206\u88c5\uff0c\u4e8e-20 \u2103\u50a8\u5b58\u3002b. \u5c061\u4efd5 mg\/mL\u7684DNase I\u50a8\u5b58\u6db2\u52a0\u523049\u4efd\u7ec6\u80de\u57f9\u517b\u57fa\u4e2d\uff0c\u5236\u5907\u7ec8\u6d53\u5ea6\u4e3a100 \u00b5g\/mL\u7684DNase I\u5de5\u4f5c\u6db2\u3002\u4e8e4 \u2103\u4e0b\u4f7f\u7528\u3002<\/li>\n\n\n\n<li>LIVE\/DEAD\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u5de5\u4f5c\u6db2\uff1aa. \u6309\u7167\u8be5\u67d3\u6599\u7684\u8bf4\u660e\u4e66\uff0c\u5411\u7ba1\u4e2d\u52a0\u516550 \u03bcL DMSO\uff0c\u4ee5\u6eb6\u89e3 LIVE\/DEAD Fixable NIR 876\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u3002b. LIVE\/DEAD Fixable NIR 876\u67d3\u6599\u5e94\u8fdb\u884c\u6ef4\u5b9a\uff0c\u6765\u4f18\u5316\u6d3b\/\u6b7b\u7ec6\u80de\u5206\u7fa4\u6548\u679c\u548c\u907f\u514d\u80cc\u666f\u5e72\u6270\u3002\u5efa\u8bae\u4f7f\u75281\u00d7 PBS\u7f13\u51b2\u6db2\uff0c\u4ee51:1000\u7684\u7a00\u91ca\u6bd4\u4f8b\u4e3a\u8d77\u59cb\u68af\u5ea6\u6765\u6ef4\u5b9a\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6837\u672c\u6d88\u5316\u4e0e\u67d3\u8272<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u672c\u5b9e\u9a8c\u65b9\u6848\u9002\u54083\u4e2a\u813e\u810f\u7684\u5b9e\u9a8c\u6750\u6599\u4f7f\u7528\u91cf\u3002\u6839\u636e\u5177\u4f53\u7684\u7ec4\u7ec7\u89e3\u79bb\u6b65\u9aa4\uff0c\u9002\u5f53\u8c03\u6574\u8bd5\u5242\u7684\u7528\u91cf\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u53d63\u4e2a\u65b0\u9c9c\u7684\u5c0f\u9f20\u813e\u810f\u3002<\/li>\n\n\n\n<li>\u5c06\u5c0f\u9f20\u813e\u810f\u653e\u5165\u542b5 mL HBSS\u7f13\u51b2\u6db2\uff08Hanks&#8217; \u5e73\u8861\u76d0\u6eb6\u6db2\uff09\u7684\u57f9\u517b\u76bf\u4e2d\u3002<\/li>\n\n\n\n<li>\u4f7f\u7528\u5200\u7247\u6216\u624b\u672f\u5200\uff0c\u5c0f\u5fc3\u5c06\u813e\u810f\u5207\u6210\u5c0f\u5757\uff08~0.2 cm<sup>2<\/sup>\uff09\u3002\u82e5\u53ea\u8fdb\u884c\u7b80\u5355\u7684\u7ec6\u80de\u5206\u79bb\uff0c\u76f4\u63a5\u8fdb\u884c\u7b2c5\u6b65\u3002<\/li>\n\n\n\n<li>\u9ad3\u7cfb\u7ec6\u80de\u5236\u5907\u5982\u4e0b\uff1a\u572837\u00b0C\u4e0b\uff0c\u4f7f\u75285 mL\u542bIV\u578b\u80f6\u539f\u9176\uff08100 U\/mL\uff09\u548c1% FBS\u7684DNase\uff0820 \u03bcg\/mL\uff09\u7684HBSS\u6eb6\u6db2\u6d88\u5316\u5c0f\u5757\u72b6\u7684\u813e\u810f\uff0c\u5b75\u80b220\u201330\u5206\u949f\u3002\u7136\u540e\u52a0\u51651 mM\/mL EDTA\uff0c\u5728\u5ba4\u6e29\u4e0b\u6d88\u53165\u5206\u949f\u540e\uff0c\u7ec8\u6b62\u9176\u6d88\u5316\u53cd\u5e94\u3002<\/li>\n\n\n\n<li>\u5c06\u7ec6\u80de\u7b5b\u653e\u572850 mL\u79bb\u5fc3\u7ba1\u4e0a\u65b9\u3002<\/li>\n\n\n\n<li>\u4f7f\u7528\u4e00\u6b21\u6027\u79fb\u6db2\u5668\uff0c\u5c06\u6d88\u5316\u540e\u7684\u813e\u7ec4\u7ec7\u8f6c\u79fb\u5230\u7ec6\u80de\u7b5b\u4e0a\u3002<\/li>\n\n\n\n<li>\u4f7f\u7528\u6ce8\u5c04\u5668\u67f1\u585e\u7aef\uff0c\u6363\u788e\u6216\u78be\u788e\u813e\u810f\uff0c\u4f7f\u5176\u901a\u8fc7\u7b5b\u7f51\u3002\u5982\u6709\u9700\u8981\uff0c\u52a0\u51655\u201310 mL PBS\u51b2\u6d17\u3002<\/li>\n\n\n\n<li>\u7528\u9002\u91cf\u7684PBS\u51b2\u6d17\u7ec6\u80de\uff0c\u4f7f\u5176\u901a\u8fc7\u7b5b\u7f51\u3002\u5982\u6709\u5fc5\u8981\uff0c\u91cd\u590d\u7b2c5\u30016\u6b65\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e1 mL\u7ec6\u80de\u57f9\u517b\u57fa\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u52a0\u51653 mL\u7ea2\u7ec6\u80de\u88c2\u89e3\u6db2\uff0c\u5ba4\u6e29\u5b75\u80b23\u5206\u949f\uff0c\u671f\u95f4\u5076\u5c14\u8f7b\u8f7b\u6447\u52a8\u3002<\/li>\n\n\n\n<li>\u52a0\u516520 mL DNase \u6d88\u5316\u6db2\u4ee5\u7ec8\u6b62\u88c2\u89e3\uff0c\u5e76\u901a\u8fc7\u964d\u89e3\u6e38\u79bbDNA\u9632\u6b62\u7ec6\u80de\u805a\u96c6\u6210\u56e2\u3002<\/li>\n\n\n\n<li>\u8f7b\u8f7b\u98a0\u5012\u7ec6\u80de\u60ac\u6db2\u6570\u6b21\u4f7f\u5176\u6df7\u5300\uff0c\u7ecf70 \u03bcm\u7ec6\u80de\u6ee4\u7f51\u8fc7\u6ee4\u81f3\u65b0\u768450 mL\u9525\u5f62\u7ba1\u4e2d\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e10 mL DNase\u6d88\u5316\u6db2\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\uff0c\u4e8e4 \u2103\u5b75\u80b215\u5206\u949f\u3002<\/li>\n\n\n\n<li>\u7ec6\u80de\u8ba1\u6570\uff0c\u786e\u5b9a\u5408\u9002\u7684\u91cd\u60ac\u4f53\u79ef\uff08\u53c2\u89c1\u540e\u7eed\u6b65\u9aa4\uff09\u3002<\/li>\n\n\n\n<li>\u52a0\u516520 mL\u7ec6\u80de\u57f9\u517b\u57fa\uff0c\u98a0\u5012\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u7ec6\u80de\u91cd\u60ac\u4e8e10 mL\u7ec6\u80de\u57f9\u517b\u57fa\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u52a0\u516520 mL\u7ec6\u80de\u57f9\u517b\u57fa\uff0c\u98a0\u5012\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u6839\u636e\u4e0a\u8ff0\u8ba1\u6570\u7ed3\u679c\uff0c\u5c06\u7ec6\u80de\u91cd\u60ac\u4e8e\u6d41\u5f0f\u67d3\u8272\u7f13\u51b2\u6db2\u4e2d\uff0c\u8c03\u6574\u6d3b\u7ec6\u80de\u6d53\u5ea6\u4e3a3\u00d710<sup>7<\/sup>\u4e2a\u6d3b\u7ec6\u80de\/mL\u3002<\/li>\n\n\n\n<li>\u52a0\u5165\u5c0f\u9f20CD16\/32\u5355\u514b\u9686\u6297\u4f53\uff08\u6bcf100 \u00b5L\u7ec6\u80de\u60ac\u6db2\u6dfb\u52a01 \u00b5L\uff09\uff0c\u4e8e4 \u2103\u5b75\u80b25\u5206\u949f\u3002<\/li>\n\n\n\n<li>\u5236\u5907\u6df7\u5408\u6d3b\/\u6b7b\u7ec6\u80de\u60ac\u6db2\u7528\u4e8e\u6b7b\u6d3b\u67d3\u6599\u5355\u8272\u67d3\u8272\u5bf9\u7167\u7ba1\uff1aa. \u5c06100 \u00b5L\u7ec6\u80de\u60ac\u6db2\u4e8e65 \u2103\u4e2d\u70ed\u6fc05\u5206\u949f\uff1bb. \u5c06\u70ed\u6fc0\u5904\u7406\u7684\u7ec6\u80de\u5feb\u901f\u51b7\u5374\u81f34\u2103\uff0c\u968f\u540e\u52a0\u516550 \u00b5L\u65b0\u9c9c\u7ec6\u80de\u60ac\u6db2\uff0c\u5236\u5907\u6d3b\/\u6b7b\u7ec6\u80de\u6df7\u5408\u5bf9\u7167\u6837\u672c\u3002<\/li>\n\n\n\n<li>\u5411\u5404\u9884\u6807\u8bb0\u7ba1\u4e2d\u52a0\u5165\u9002\u91cf\u6297\u4f53\u6216\u6297\u4f53\u9884\u6df7\u6db2\u3002<\/li>\n\n\n\n<li>\u6bcf\u652f\u6837\u672c\u7ba1\u548c\u5bf9\u7167\u7ba1\u4e2d\u52a0\u5165100 \u00b5L\u7ec6\u80de\u60ac\u6db2\uff083\u00d710<sup>6&nbsp;<\/sup>\u4e2a\u7ec6\u80de\uff09\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002\u6ce8\uff1a\u4f7f\u7528\u7b2c19\u6b65\u5236\u5907\u7684\u6df7\u5408\u6d3b\/\u6b7b\u7ec6\u80de\u4f5c\u4e3a\u6d3b\/\u6b7b\u7ec6\u80de\u5355\u67d3\u5bf9\u7167\u6837\u672c\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u907f\u5149\u5b75\u80b230\u5206\u949f\u3002<\/li>\n\n\n\n<li>\u5411\u6bcf\u4efd\u7ec6\u80de\u60ac\u6db2\u4e2d\u52a0\u51653 mL 1\u00d7 PBS\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u6bcf\u4efd\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e3 mL 1\u00d7 PBS\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u6bcf\u4efd\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e100 \u00b5L\u6d41\u5f0f\u67d3\u8272\u7f13\u51b2\u6db2\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u5411\u5b8c\u5168\u67d3\u8272\u7684\u6837\u672c\u3001\u76f8\u5e94\u7684FMO\u5bf9\u7167\u53ca\u6d3b\/\u6b7b\u7ec6\u80de\u5bf9\u7167\u4e2d\u52a0\u5165 10 \u00b5L\u7684LIVE\/DEAD\u5de5\u4f5c\u6db2\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u907f\u5149\u5b75\u80b220\u5206\u949f\u3002<\/li>\n\n\n\n<li>\u5411\u6bcf\u4efd\u7ec6\u80de\u60ac\u6db2\u4e2d\u52a0\u51653 mL\u6d41\u5f0f\u67d3\u8272\u7f13\u51b2\u6db2\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u6bcf\u4efd\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e3 mL \u6d41\u5f0f\u67d3\u8272\u7f13\u51b2\u6db2\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u4e8e4 \u2103\u4e0b\u4ee5400\u00d7g\u79bb\u5fc35\u5206\u949f\uff0c\u968f\u540e\u8f7b\u8f7b\u503e\u5012\u5f03\u53bb\u4e0a\u6e05\u6db2\u3002<\/li>\n\n\n\n<li>\u5c06\u6bcf\u4efd\u7ec6\u80de\u6c89\u6dc0\u91cd\u60ac\u4e8e100 \u00b5L\u6d41\u5f0f\u67d3\u8272\u7f13\u51b2\u4e2d\uff0c\u8f7b\u8f7b\u5439\u6253\u6df7\u5300\u3002<\/li>\n\n\n\n<li>\u7acb\u5373\u8fdb\u884c\u4e0a\u673a\u68c0\u6d4b\uff0c\u6216\u8fdb\u884c\u540e\u7eed\u7684\u7ec6\u80de\u56fa\u5b9a\u7834\u819c\u6b65\u9aa4\uff0c\u68c0\u6d4b\u7ec6\u80de\u5185\u7684\u86cb\u767d\u9776\u6807\u8868\u8fbe\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1aLIVE\/DEAD\u53ef\u56fa\u5b9a\u7ec6\u80de\u6d3b\u6027\u67d3\u6599\u9002\u7528\u4e8e\u65b0\u9c9c\u6837\u672c\uff0c\u5e76\u4e14\u5728\u591a\u79cd\u56fa\u5b9a\u5242\u4e2d\u90fd\u80fd\u4fdd\u6301\u7a33\u5b9a\u3002\u82e5\u4f7f\u7528\u5176\u4ed6\u7ec6\u80de\u6d3b\u6027\u68c0\u6d4b\u67d3\u6599\uff0c\u9700\u8981\u5728\u9884\u5b9e\u9a8c\u4e2d\u63d0\u524d\u8fdb\u884c\u6d4b\u8bd5\uff0c\u786e\u4fdd\u7ec6\u80de\u56fa\u5b9a\u524d\u540e\u6b7b\u6d3b\u7ec6\u80de\u67d3\u8272\u6548\u679c\u4e00\u81f4\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5fae\u7403\u5bf9\u7167\u5236\u5907\"><strong>\u5fae\u7403\u5bf9\u7167\u5236\u5907<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u6309\u7167\u8bf4\u660e\u4e66\u5236\u5907UltraComp eBeads Plus\u8865\u507f\u5fae\u7403\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u6dfb\u52a0\u6d41\u5f0f\u7ec6\u80de\u5185\u56fa\u5b9a\u7834\u819c\u7f13\u51b2\u6db2\u5230\u5fae\u7403\u4e2d\uff0c\u6216\u662f\u7acb\u5373\u4e0a\u6837\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u5fae\u7403\u5bf9\u7167\u7684\u6837\u672c\u5904\u7406\u65b9\u5f0f\u5e94\u4e0e\u67d3\u8272\u7684\u7ec6\u80de\u5bf9\u7167\u4e00\u81f4\u3002\u56e0\u6b64\uff0c\u82e5\u5bf9\u5355\u67d3\u5bf9\u7167\u548c\u6837\u672c\u8fdb\u884c\u4e86\u56fa\u5b9a\u548c\/\u6216\u7834\u819c\u5904\u7406\uff0c\u5219\u9700\u5bf9\u5fae\u7403\u5bf9\u7167\u4f7f\u7528\u76f8\u540c\u7684\u5b9e\u9a8c\u6d41\u7a0b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"332\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221616@2x-1024x332.png\" alt=\"\" class=\"wp-image-1450\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221616@2x-1024x332.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221616@2x-300x97.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221616@2x-768x249.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221616@2x.png 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Invitrogen\u2122 Attune\u2122 Xenith\u2122 \u662f\u8d5b\u9ed8\u98de\u5168\u65b0\u63a8\u51fa\u7684\u4e00\u6b3e\u5feb\u901f\u4e14\u6297\u5835\u7684\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\uff0c\u5c06\u58f0\u6ce2\u805a\u7126\u4e13\u5229\u6280\u672f\u4e0e\u5168\u5149\u8c31\u89e3\u6790\u529f\u80fd\u5b8c\u7f8e\u7ed3\u5408\uff0c\u65e8\u5728\u4e3a\u524d\u6cbf\u7684\u79d1\u5b66\u7814\u7a76\u63d0\u4f9b\u4e00\u79cd\u9ad8\u6548\u3001\u7075\u654f\u3001\u53ef\u9760\u7684\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5176\u4e3b\u8981\u6280\u672f\u4f18\u52bf\u4e3a\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5168\u5149\u8c31\uff1a<\/strong>\u914d\u7f6e\u9ad8\u8fbe6\u6fc0\u514957\u53c2\u6570<\/li>\n\n\n\n<li><strong>\u901f\u5ea6\u5feb\uff1a<\/strong>\u4e0a\u6837\u901f\u5ea6\u6bd4\u5176\u4ed6\u5149\u8c31\u6d41\u5f0f\u4eea\u5feb5\u500d<\/li>\n\n\n\n<li><strong>\u6297\u5835\uff1a<\/strong>\u4e13\u4e1a\u6297\u5835\u585e\u8bbe\u8ba1<\/li>\n\n\n\n<li><strong>\u7075\u654f\uff1a<\/strong>\u5c24\u5176\u9002\u5408\u7a00\u6709\u7ec6\u80de\u68c0\u6d4b<\/li>\n\n\n\n<li><strong>\u81ea\u52a8\u5316\uff1a<\/strong>\u914d\u5957\u6d41\u5f0f\u81ea\u52a8\u5316\u5de5\u4f5c\u7ad9<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u514d\u75ab\u8868\u578b\u5206\u6790\u662f\u901a\u8fc7\u6d41\u5f0f\u7ec6\u80de\u672f\u68c0\u6d4b\u7ec6\u80de\u8868\u9762\u6216\u5185\u90e8\u7684\u7279\u5b9a\u6297\u539f\u6807\u8bb0\u7269\uff0c\u7528\u4e8e\u75be\u75c5\u8bca\u65ad\uff08\u5c24\u5176\u662f\u8840\u6db2\u80bf\u7624\u5206\u578b\uff09\u548c\u7ec6\u80de\u529f\u80fd\u7814<\/p>\n","protected":false},"author":1852,"featured_media":1448,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[150],"division":[9],"class_list":["post-1444","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-150","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-10T03:34:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:22+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1084\" \/>\n\t<meta property=\"og:image:height\" content=\"544\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f\",\"datePublished\":\"2026-04-10T03:34:56+00:00\",\"dateModified\":\"2026-04-22T21:59:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/\"},\"wordCount\":161,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-221441@2x.png\",\"keywords\":[\"\u514d\u75ab\u8868\u578b\u5206\u6790\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/\",\"name\":\"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-221441@2x.png\",\"datePublished\":\"2026-04-10T03:34:56+00:00\",\"dateModified\":\"2026-04-22T21:59:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-221441@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-221441@2x.png\",\"width\":1084,\"height\":544},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/attune-xenith-technotes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/","og_locale":"zh_CN","og_type":"article","og_title":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f","og_description":"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-04-10T03:34:56+00:00","article_modified_time":"2026-04-22T21:59:22+00:00","og_image":[{"width":1084,"height":544,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f","datePublished":"2026-04-10T03:34:56+00:00","dateModified":"2026-04-22T21:59:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/"},"wordCount":161,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png","keywords":["\u514d\u75ab\u8868\u578b\u5206\u6790"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/","name":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png","datePublished":"2026-04-10T03:34:56+00:00","dateModified":"2026-04-22T21:59:22+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u672c\u6280\u672f\u6307\u5357\u4e3b\u8981\u63a2\u8ba8\u4e86\u6837\u672c\u8d28\u91cf\u4e0e\u6570\u636e\u91c7\u96c6\u7a33\u5b9a\u6027\u5bf9\u5b9e\u73b0\u6df1\u5ea6\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u4e86Attune Xenith\u5168\u5149\u8c31\u6d41\u5f0f\u7ec6\u80de\u4eea\u5728\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\u4e2d\u7684\u5353\u8d8a\u6027\u80fd\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x.png","width":1084,"height":544},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/attune-xenith-technotes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u6280\u672f\u6307\u5357\uff5c\u5982\u4f55\u5229\u7528Attune Xenith\u6d41\u5f0f\u7ec6\u80de\u4eea\u7684\u5149\u8c31\u89e3\u6790\u529f\u80fd\u63d0\u9ad8\u514d\u75ab\u8868\u578b\u5206\u6790\u7684\u51c6\u786e\u6027\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":150,"label":"\u514d\u75ab\u8868\u578b\u5206\u6790"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-221441@2x-1024x514.png",760,381,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":2,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":150,"name":"\u514d\u75ab\u8868\u578b\u5206\u6790","slug":"%e5%85%8d%e7%96%ab%e8%a1%a8%e5%9e%8b%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":150,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1444"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1444\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1448"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1444"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1444"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1444"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}