{"id":1489,"date":"2026-04-03T06:43:37","date_gmt":"2026-04-03T06:43:37","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1489"},"modified":"2026-04-22T21:59:23","modified_gmt":"2026-04-22T21:59:23","slug":"adc-research-tool","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/adc-research-tool\/","title":{"rendered":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u7814\u7a76\u6297\u4f53\u5076\u8054\u836f\u7269\"><strong>\u4e3a\u4ec0\u4e48\u7814\u7a76\u6297\u4f53\u5076\u8054\u836f\u7269\uff1f<\/strong><\/h2>\n\n\n\n<p><strong>\u6297\u4f53\u5076\u8054\u836f\u7269<\/strong>&nbsp;(Antibody Drug Conjugates, ADCs) \u5f7b\u5e95\u6539\u53d8\u4e86\u9776\u5411\u7597\u6cd5\uff0c\u7279\u522b\u662f\u5728\u764c\u75c7\u548c\u5176\u4ed6\u590d\u6742\u75be\u75c5\u6cbb\u7597\u9886\u57df\u3002\u9776\u5411\u7597\u6cd5\u7684\u6982\u5ff5\u53ef\u4ee5\u8ffd\u6eaf\u5230 1906 \u5e74\uff0c\u5f53\u65f6 Paul Ehrlich \u63d0\u51fa\u4e86\u201c\u9b54\u6cd5\u5b50\u5f39\u201d\u2014\u2014\u5c06\u836f\u7269\u76f4\u63a5\u9776\u5411\u75be\u75c5\u90e8\u4f4d\u300220 \u4e16\u7eaa 70 \u5e74\u4ee3\uff0c\u968f\u7740\u6742\u4ea4\u7624\u6280\u672f\u7684\u53d1\u5c55\uff0c\u8be5\u9886\u57df\u53d6\u5f97\u4e86\u91cd\u5927\u8fdb\u5c55\uff0c\u5b9e\u73b0\u4e86\u5355\u514b\u9686\u6297\u4f53\u7684\u5927\u89c4\u6a21\u751f\u4ea7\u3002\u4ece\u90a3\u65f6\u8d77\uff0c\u6297\u4f53\u5c31\u88ab\u7528\u5728\u514d\u75ab\u7ec6\u80de\u62db\u52df\u3001\u7279\u5f02\u8868\u4f4d\u963b\u65ad\uff0c\u5e76\u5c06\u7ec6\u80de\u6bd2\u6027\u836f\u7269\u76f4\u63a5\u9012\u9001\u5230\u9776\u7ec6\u80de\uff0c\u4ece\u800c<strong>\u663e\u8457\u62d3\u5bbd\u4e86\u6cbb\u7597\u7a97\u5e76\u964d\u4f4e\u4e86\u6bd2\u6027<\/strong>\u3002<\/p>\n\n\n\n<p>\u81ea\u4ece2000\u5e74\u9996\u4e2aADC\u836f\u7269\u83b7\u6279\u4ee5\u6765\uff0cADC\u5e02\u573a\u5448\u73b0<strong>\u7206\u53d1\u5f0f\u589e\u957f<\/strong>\uff0c\u56e0\u6b64\u9ad8\u6548ADC\u7b5b\u9009\u548c\u9274\u5b9a\u5de5\u5177\u5bf9\u52a0\u901f\u7597\u6cd5\u5f00\u53d1\u7684\u91cd\u8981\u6027\u4e5f\u65e5\u76ca\u589e\u5927\u3002<\/p>\n\n\n\n<p>\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0<strong>\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a<\/strong>\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9<strong>\u5404\u4e2a\u5e73\u53f0<\/strong>\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002\u672c\u6587\u68b3\u7406\u4e86\u4ee5\u4e0b\u56db\u4e2a\u7ef4\u5ea6\u7684ADC\u7814\u7a76\u9ad8\u6548\u5de5\u5177\uff1a<\/p>\n\n\n\n<p>\u88681. ADC\u7b5b\u9009\u548c\u9274\u5b9a\u5de5\u5177\u6c47\u603b<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1020\" height=\"882\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224320@2x.png\" alt=\"\" class=\"wp-image-1490\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224320@2x.png 1020w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224320@2x-300x259.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224320@2x-768x664.png 768w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-01-\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u5de5\u5177\"><strong>01<\/strong> <strong>\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u5de5\u5177<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u4ece\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u5f00\u59cb\">\u4e3a\u4ec0\u4e48\u4ece\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u5f00\u59cb\uff1f<\/h3>\n\n\n\n<p>ADC \u5f00\u53d1\u7684\u521d\u59cb\u6b65\u9aa4\u4e4b\u4e00\u662f\u7b5b\u9009\u6297\u4f53\u7ed3\u5408\uff0c\u4ee5\u786e\u4fdd\u6297\u4f53\u80fd\u591f\u7279\u5f02\u6027\u8bc6\u522b\u5e76\u7ed3\u5408\u7ec6\u80de\u8868\u9762\u7684\u9776\u6297\u539f\u3002\u8fd9\u4e00\u70b9\u81f3\u5173\u91cd\u8981\uff0c\u56e0\u4e3a ADC \u7684\u6709\u6548\u6027\u53d6\u51b3\u4e8e\u5176\u9009\u62e9\u6027\u7ed3\u5408\u764c\u75c7\u7ec6\u80de\u7684\u540c\u65f6\u4e0d\u4f24\u5bb3\u5065\u5eb7\u7ec6\u80de\u7684\u80fd\u529b\u3002\u4ece\u6297\u4f53\u7ed3\u5408\u5f00\u59cb\u6709\u52a9\u4e8e\u8bc6\u522b\u5bf9\u9776\u6297\u539f\u5177\u6709\u9ad8\u7279\u5f02\u6027\u548c\u4eb2\u548c\u529b\u7684\u5019\u9009\u836f\u7269\uff0c\u4e3a\u540e\u7eed\u7684\u5185\u5316\u548c\u964d\u89e3\u6b65\u9aa4\u5960\u5b9a\u57fa\u7840\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7528\u4e8e\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u7684-zenon-\u8bd5\u5242\">\u7528\u4e8e\u6297\u4f53\u7ed3\u5408\u7b5b\u9009\u7684 Zenon \u8bd5\u5242<\/h3>\n\n\n\n<p>Invitrogen\u2122 Zenon\u2122 Alexa Fluor\u2122 Plus \u6807\u8bb0\u8bd5\u5242\u662f\u4e0e\u8367\u5149\u67d3\u6599\u7ed3\u5408\u7684 Fab \u7247\u6bb5\uff0c\u53ef\u5feb\u901f\u9ad8\u6548\u5730\u7b5b\u9009\u6297\u4f53\u7ed3\u5408\u3002\u8fd9\u4e9b\u8bd5\u5242\u65e8\u5728\u7279\u5f02\u6027\u5730\u7ed3\u5408\u6297\u4f53\u7684 Fc \u533a\u57df\uff0c\u63d0\u4f9b\u5f3a\u5927\u7684\u4fe1\u53f7\uff0c\u53ef\u4f7f\u7528\u5e38\u89c4\u6210\u50cf\u3001\u9ad8\u5185\u6db5\u7b5b\u9009\u6216\u6d41\u5f0f\u7ec6\u80de\u672f\u5e73\u53f0\u8f7b\u677e\u68c0\u6d4b\u3002Zenon Alexa Fluor Plus IgG \u6807\u8bb0\u8bd5\u5242\u5c06\u5feb\u901f\u4e14\u9ad8\u901a\u91cf\u7684 Zenon \u6280\u672f\u4e0e\u5353\u8d8a\u7684 Alexa Fluor Plus \u67d3\u6599\u76f8\u7ed3\u5408\uff0c\u63d0\u4f9b\u66f4\u9ad8\u7684\u7075\u654f\u5ea6\u548c\u4e00\u81f4\u6027\uff0c\u4f7f\u5176\u6210\u4e3a\u7b5b\u9009\u5927\u91cf\u5019\u9009\u6297\u4f53\u5e93\u7684\u7406\u60f3\u9009\u62e9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-invitrogen-zenon-alexa-fluor-plus\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\"><strong>Invitrogen\u2122 Zenon\u2122 Alexa Fluor\u2122 Plus\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5feb\u901f\u2014\u20145\u5206\u949f\u6297\u4f53\u5b75\u80b2<\/li>\n\n\n\n<li>\u7b80\u4fbf\u2014\u2014\u65e0\u9700\u7eaf\u5316<\/li>\n\n\n\n<li>\u9ad8\u4fe1\u566a\u6bd4<\/li>\n\n\n\n<li>\u9002\u7528\u4e8e\u591a\u79cd IgG \u4e9a\u7c7b<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"445\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x-1024x445.png\" alt=\"\" class=\"wp-image-1491\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x-1024x445.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x-300x130.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x-768x334.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png 1036w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 1. Her-2 \u9633\u6027 SKBR3 \u7ec6\u80de\u7528 Zenon Alexa Fluor Plus \u6807\u8bb0\u8bd5\u5242\u6807\u8bb0\uff08\u8d27\u53f7\u4e3e\u4f8b\uff1aZ25619\uff09\u7684\u66f2\u59a5\u73e0\u5355\u6297\u5728 37\u2103\u548c 5% CO<sub>2&nbsp;<\/sub>\u4e0b\u5904\u7406 30 \u5206\u949f\u3002\u7528 1x PBS \u6e05\u6d17\u7ec6\u80de 3 \u6b21\uff0c\u7136\u540e\u4f7f\u7528 Thermo Scientific\u2122 CellInsight\u2122 CX7 Pro \u9ad8\u5185\u6db5\u6210\u50cf\u5e73\u53f0\u8fdb\u884c\u6210\u50cf\u3002\u9634\u6027\u5bf9\u7167\uff1a\u5c06\u7ec6\u80de\u4e0e\u4e0d\u542b\u66f2\u59a5\u73e0\u5355\u6297\u7684 Zenon \u8bd5\u5242\u4e00\u8d77\u5b75\u80b2\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"501\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224357@2x-1024x501.png\" alt=\"\" class=\"wp-image-1492\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224357@2x-1024x501.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224357@2x-300x147.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224357@2x-768x376.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224357@2x.png 1050w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 2 \u4f7f\u7528 Zenon Alexa Fluor Plus 647 Human IgG \u6807\u8bb0\u8bd5\u5242\u6807\u8bb0 24 \u79cd\u5019\u9009\u6297\u4f53\uff0c\u6bcf\u79cd\u6297\u4f53\u91cd\u8bbe\u7f6e\u4e09\u4e2a\u590d\u5b54\u3002HER2\u9633\u6027SKBR3 \u7ec6\u80de\u4e0e\u6807\u8bb0\u6297\u4f53\u5171\u5b75\u80b2 24 \u5c0f\u65f6\uff0c\u7528 Hoechst \u6807\u8bb0\u5e76\u5728 Thermo Scientific\u2122 CellInsight\u2122 CX7 Pro \u5e73\u53f0\u4e0a\u8fdb\u884c\u5206\u6790\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-02-adc\u5185\u5316\u68c0\u6d4b\u5de5\u5177\"><strong>02<\/strong> <strong>ADC\u5185\u5316\u68c0\u6d4b\u5de5\u5177<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u68c0\u6d4badc\u5185\u5316\">\u4e3a\u4ec0\u4e48\u68c0\u6d4bADC\u5185\u5316\uff1f<\/h3>\n\n\n\n<p>\u4e00\u65e6\u786e\u5b9a\u4e86\u6297\u4f53\u7684\u7ed3\u5408\u7279\u5f02\u6027\uff0c\u4e0b\u4e00\u4e2a\u5173\u952e\u6b65\u9aa4\u5c31\u662f\u7b5b\u9009ADC\u7684\u5185\u5316\u3002ADC \u901a\u8fc7\u5185\u5316\u5230\u9776\u7ec6\u80de\u4e2d\u3001\u7ec6\u80de\u6bd2\u6027\u836f\u7269\u5728\u9776\u7ec6\u80de\u4e2d\u91ca\u653e\u51fa\u6765\u53d1\u6325\u6cbb\u7597\u4f5c\u7528\u3002\u7b5b\u9009\u5185\u5316\u53ef\u786e\u4fdd\u6297\u4f53\u80fd\u591f\u6709\u6548\u8fdb\u5165\u9776\u7ec6\u80de\uff0c\u8fd9\u5bf9\u4e8e\u7ec6\u80de\u6bd2\u6027\u836f\u7269\u7684\u9012\u9001\u81f3\u5173\u91cd\u8981\u3002\u6b64\u6b65\u9aa4\u6709\u52a9\u4e8e\u8bc6\u522b\u65e2\u80fd\u4e0e\u9776\u6297\u539f\u7ed3\u5408\u8fd8\u80fd\u88ab\u6709\u6548\u5185\u541e\u4f5c\u7528\u7684\u5019\u9009ADC\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u68c0\u6d4b-adc-\u5185\u5316\u7684ph-\u4f9d\u8d56\u6027\u63a2\u9488\">\u68c0\u6d4b ADC \u5185\u5316\u7684pH \u4f9d\u8d56\u6027\u63a2\u9488<\/h3>\n\n\n\n<p>Invitrogen\u2122 pHrodo\u2122 \u8bd5\u5242\u76d2\u548c\u8bd5\u5242\u91c7\u7528 pH \u654f\u611f\u6280\u672f\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u9ad8\u5ea6\u7279\u5f02\u6027\u5730\u7814\u7a76\u80de\u541e\u4f5c\u7528\u6216\u541e\u566c\u4f5c\u7528\u3002pHrodo \u67d3\u6599\u6709\u7ea2\u8272\u3001\u7eff\u8272\u548c\u6df1\u7ea2\u8272\u4e09\u8272\u53ef\u4f9b\u9009\u62e9\uff0c\u5728\u7ec6\u80de\u5916\u73af\u5883\u7684\u4e2d\u6027 pH \u4e0b\u4e0d\u53d1\u8367\u5149\u3002\u53ea\u6709\u5f53\u5185\u5316\u5230\u5185\u4f53\u6216\u6eb6\u9176\u4f53\u7684\u9178\u6027\u73af\u5883\u4e2d\u65f6\uff0cpH \u654f\u611f\u67d3\u6599\u624d\u4f1a\u53d1\u51fa\u660e\u4eae\u7684\u8367\u5149\u3002\u901a\u8fc7\u5c06\u8fd9\u4e9b\u67d3\u6599\u4e0e ADC \u7ed3\u5408\uff0c\u7814\u7a76\u4eba\u5458\u53ef\u4ee5\u4f7f\u7528\u6d3b\u7ec6\u80de\u6210\u50cf\u6216\u6d41\u5f0f\u7ec6\u80de\u672f\u53ef\u89c6\u5316\u548c\u91cf\u5316\u5185\u5316\u8fc7\u7a0b\uff0c\u4e14\u65e0\u9700\u4efb\u4f55\u6e05\u6d17\u6b65\u9aa4\u3002\u5185\u5316\u7684\u5b9e\u65f6\u76d1\u6d4b\u4e3a ADC \u5f00\u53d1\u63d0\u4f9b\u4e86\u5173\u952e\u4fe1\u606f\uff0c\u786e\u4fdd\u6cbb\u7597\u80de\u6bd2\u836f\u7269\u6709\u6548\u5730\u9012\u9001\u5230\u9776\u7ec6\u80de\u3002<\/p>\n\n\n\n<p>Invitrogen pHrodo \u67d3\u6599\u7684 pH \u654f\u611f\u6280\u672f\u53ef\u4e0e\u5176\u4ed6\u6807\u8bb0\u6280\u672f\u76f8\u7ed3\u5408\u3002\u8fd9\u4e9b\u6280\u672f\u5305\u62ec\u7528\u4e8e\u4e0e\u66b4\u9732\u7684\u8d56\u6c28\u9178\u6b8b\u57fa\u7ed3\u5408\u7684\u80fa\u53cd\u5e94\u6027\u67d3\u6599\u3001\u4f7f\u7528 SiteClick \u6297\u4f53\u6807\u8bb0\u8bd5\u5242\u76d2\u7684\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\u4ee5\u53ca\u5feb\u901f Zenon \u6297\u4f53\u6807\u8bb0\u65b9\u6cd5\uff0c\u4ee5\u6ee1\u8db3\u60a8\u7279\u5b9a\u7684\u5185\u5316\u68c0\u6d4b\u9700\u6c42\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-invitrogen-phrodo-\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\"><strong>Invitrogen\u2122 pHrodo\u2122 \u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4fe1\u53f7\u5f3a\uff1a\u5728\u9178\u6027 pH \u4e0b\u53d1\u51fa\u660e\u4eae\u8367\u5149<\/li>\n\n\n\n<li>\u80cc\u666f\u4f4e\uff1a\u5728\u4e2d\u6027 pH \u4e0b\u4fe1\u53f7\u6781\u4f4e<\/li>\n\n\n\n<li>\u9002\u7528\u4e8e\u4e0e\u6297\u4f53\u548c\u914d\u4f53\u7ed3\u5408<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"283\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224456@2x-1024x283.png\" alt=\"\" class=\"wp-image-1493\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224456@2x-1024x283.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224456@2x-300x83.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224456@2x-768x212.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224456@2x.png 1028w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 3. pHrodo Deep Red \u5728\u665a\u671f\u5185\u4f53\u548c\u6eb6\u9176\u4f53\u4e2d\uff08pH \u503c5.5-6.0\uff09\u53d1\u51fa\u8367\u5149\u3002\u7528 pHrodo Deep Red \uff08\u8d27\u53f7\uff1aP35355\uff09\u6807\u8bb0\u7684\u8d6b\u8d5b\u6c40\u5904\u7406SKBR3 \u7ec6\u80de\uff0c\u968f\u540e\u6210\u50cf\uff1a\u665a\u671f\u5185\u4f53\u548c\u6eb6\u9176\u4f53\u4e2d\u6709\u8367\u5149\uff0c\u4f46\u5728\u65e9\u671f\u5185\u4f53\u4e2d\u65e0\u8367\u5149\u3002\u6b64\u5b9e\u9a8c\u8bc1\u5b9e\u4e86 pHrodo Deep Red \u4ec5\u5728\u9178\u6027\u6761\u4ef6\u4e0b\u6d3b\u5316\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5feb\u901f\u68c0\u6d4badc\u5185\u5316\u7684zenon-phrodo-\u8bd5\u5242\">\u5feb\u901f\u68c0\u6d4bADC\u5185\u5316\u7684Zenon pHrodo \u8bd5\u5242<\/h3>\n\n\n\n<p>Invitrogen\u2122 Zenon\u2122 pHrodo\u2122 \u8bd5\u5242\u662f\u4e00\u79cd\u975e\u5e38\u5feb\u901f\u6807\u8bb0 IgG \u6297\u4f53\u7684\u65b9\u6cd5\uff0c\u53ef\u7528\u4e8e\u68c0\u6d4bADC\u5185\u5316\u3002Zenon \u6807\u8bb0\u8fc7\u7a0b\u5305\u62ec\u5c06\u76ee\u6807\u4e00\u6297\u4e0e pHrodo \u5076\u8054\u7684 Zenon fab \u7247\u6bb5\u4e00\u8d77\u5b75\u80b2\uff0c\u5728 5 \u5206\u949f\u5185\u5f62\u6210\u6297\u4f53\u590d\u5408\u7269\u3002\u8fd9\u79cd\u975e\u5171\u4ef7\u76f8\u4e92\u4f5c\u7528\u8db3\u591f\u7a33\u5b9a\uff0c\u53ef\u4ee5\u68c0\u6d4b\u7ec6\u80de\u5185\u7684\u5185\u5316\u548c\u8fd0\u8f93\u3002\u6807\u8bb0\u540e\u7684\u6297\u4f53\u53ef\u7528\u4e8e\u5404\u79cd\u5e94\u7528\uff0c\u5305\u62ec\u6d3b\u7ec6\u80de\u6210\u50cf\u548c\u6d41\u5f0f\u7ec6\u80de\u672f\uff0c\u4e3a\u6297\u4f53\u5185\u5316\u52a8\u529b\u5b66\u63d0\u4f9b\u6709\u4ef7\u503c\u7684\u89c1\u89e3\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-zenon-phrodo-\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\"><strong>Zenon pHrodo \u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5feb\u901f\u2014\u20145 \u5206\u949f\u5b8c\u6210\u6807\u8bb0<\/li>\n\n\n\n<li>\u7a33\u5b9a\u2014\u2014\u975e\u5171\u4ef7\u4f46\u7a33\u5b9a\u7684\u76f8\u4e92\u4f5c\u7528<\/li>\n\n\n\n<li>\u4fdd\u7559\u6297\u4f53\u529f\u80fd\u2014\u2014\u7279\u5b9a\u4e8e Fc \u90e8\u5206\uff0c\u4fdd\u7559\u6297\u539f\u7ed3\u5408\u4f4d\u70b9<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"622\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224527@2x.png\" alt=\"\" class=\"wp-image-1494\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224527@2x.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224527@2x-300x182.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224527@2x-768x467.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 4. \u7528 Zenon pHrodo Deep Red \uff08\u8d27\u53f7Z25618\uff09\u6807\u8bb0\u7684\u66f2\u59a5\u73e0\u5355\u6297\u6216 Zenon pHrodo Deep Red \uff08\u8d27\u53f7Z25622\uff09\u6807\u8bb0\u7684\u6297\u8f6c\u94c1\u86cb\u767d\u53d7\u4f53\u5904\u7406SKBR3 \u7ec6\u80de 16 \u5c0f\u65f6\uff0c\u4ee5\u4f7f\u5355\u6297\u6216\u53d7\u4f53\u5b8c\u5168\u5185\u5316\u3002\u5728\u6210\u50cf\u4e4b\u524d\uff0c\u7528 50 nM Invitrogen LysoTracker Red \u5904\u7406\u7ec6\u80de 1 \u5c0f\u65f6\u3002\u4f7f\u7528 RFP \u548c Cy5 \u6ee4\u5149\u7247\u5728 Invitrogen EVOS M7000 \u6210\u50cf\u7cfb\u7edf\u4e0a\u6210\u50cf\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-03-\u76d1\u6d4badc\u6eb6\u9176\u4f53\u964d\u89e3\u7684\u5de5\u5177\"><strong>03<\/strong> <strong>\u76d1\u6d4bADC\u6eb6\u9176\u4f53\u964d\u89e3\u7684\u5de5\u5177<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u8981\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3\">\u4e3a\u4ec0\u4e48\u8981\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3\uff1f<\/h3>\n\n\n\n<p>\u786e\u4fdd\u6297\u4f53\u4e0e\u9776\u6297\u539f\u7ed3\u5408\u5e76\u6709\u6548\u5185\u5316\u540e\uff0c\u4e0b\u4e00\u6b65\u662f\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3\u3002\u8fd9\u4e00\u70b9\u81f3\u5173\u91cd\u8981\uff0c\u56e0\u4e3a ADC \u7684\u6cbb\u7597\u6548\u679c\u53d6\u51b3\u4e8e\u6eb6\u9176\u4f53\u5185\u7ec6\u80de\u6bd2\u6027\u836f\u7269\u7684\u91ca\u653e\u3002\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3\u53ef\u786e\u8ba4\u5185\u5316\u7684 ADC \u88ab\u8fd0\u9001\u5230\u6eb6\u9176\u4f53\uff0c\u836f\u7269\u5728\u90a3\u91cc\u88ab\u91ca\u653e\u4ee5\u53d1\u6325\u6cbb\u7597\u4f5c\u7528\u3002\u6b64\u6b65\u9aa4\u6709\u52a9\u4e8e\u8bc6\u522b\u5185\u541e\u540e\u5230\u8fbe\u6eb6\u9176\u4f53\u91ca\u653e\u836f\u7269\u7684\u6297\u4f53\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7528\u4e8e\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3lysolight-\u8bd5\u5242\">\u7528\u4e8e\u76d1\u6d4b\u6eb6\u9176\u4f53\u964d\u89e3LysoLight \u8bd5\u5242<\/h3>\n\n\n\n<p>Invitrogen\u2122 LysoLight\u2122 \u6297\u4f53\u6807\u8bb0\u8bd5\u5242\u76d2\u548c\u6d3b\u6027\u67d3\u6599\u662f\u76d1\u6d4b\u6eb6\u9176\u4f53\u5185 ADC \u5206\u89e3\u4ee3\u8c22\u7684\u6709\u529b\u5de5\u5177\u3002\u4e0e pH\u4f9d\u8d56\u7684 pHrodo \u6280\u672f\u4e0d\u540c\uff0cLysoLight \u5076\u8054\u6297\u4f53\u6216\u86cb\u767d\u8d28\u5373\u4f7f\u5728\u665a\u671f\u5185\u4f53\u4e2d\u4e5f\u4e0d\u4f1a\u53d1\u51fa\u8367\u5149\uff0c\u53ea\u6709\u5728\u88ab\u6eb6\u9176\u4f53\u86cb\u767d\u9176\u88c2\u89e3\u65f6\u624d\u4f1a\u53d1\u51fa\u8367\u5149\u3002\u8fd9\u79cd\u673a\u5236\u63d0\u4f9b\u4e86\u5353\u8d8a\u7684\u7075\u654f\u5ea6\u548c\u7279\u5f02\u6027\uff0c\u7528\u4ee5\u7cbe\u51c6\u68c0\u6d4b\u86cb\u767d\u8d28\u6216 ADC \u7684\u5185\u5316\u548c\u8fd0\u8f93\u3002\u4f7f\u7528 LysoLight \u6280\u672f\uff0c\u7814\u7a76\u4eba\u5458\u8fd8\u53ef\u4ee5\u8bc4\u4f30\u9776\u5411\u86cb\u767d\u8d28\u964d\u89e3\u5019\u9009\u5206\u5b50\u5bf9\u5206\u89e3\u4ee3\u8c22\u6216\u5faa\u73af\u9014\u5f84\u7684\u503e\u5411\u3002\u8fd9\u53ef\u4ee5\u5e2e\u52a9\u9776\u5411\u86cb\u767d\u8d28\u964d\u89e3\u9886\u57df\u7684\u7814\u7a76\u4eba\u5458\u5fae\u8c03\u4ed6\u4eec\u7684\u5019\u9009\u7269\u4ee5\u83b7\u5f97\u6700\u5927\u7684\u6cbb\u7597\u6f5c\u529b\u3002LysoLight \u8bd5\u5242\u76d2\u548c\u8bd5\u5242\u4e0e\u591a\u79cd\u5e73\u53f0\u517c\u5bb9\uff0c\u4f8b\u5982\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u5206\u6790\u7cfb\u7edf\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-lysolight-\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\"><strong>LysoLight \u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u65e0\u80cc\u666f\uff1a\u5728\u6eb6\u9176\u4f53\u4e2d\u88c2\u89e3\u524d\u4e0d\u53d1\u8367\u5149<\/li>\n\n\n\n<li>\u517c\u5bb9\u5404\u79cd\u6210\u50cf\u548c\u6d41\u5f0f\u7ec6\u80de\u672f\u5e73\u53f0<\/li>\n\n\n\n<li>\u517c\u5bb9\u7c7b\u5668\u5b98\u548c\u7c7b\u80bf\u7624\u7b49 3D \u6a21\u578b<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-1024x1024.png\" alt=\"\" class=\"wp-image-1495\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-1024x1024.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-300x300.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-150x150.png 150w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-768x768.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x-80x80.png 80w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224554@2x.png 1032w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 5. LysoLight \u67d3\u6599\u662f\u7528\u4e8e\u76f4\u63a5\u76d1\u6d4b\u76ee\u6807\u86cb\u767d\u6eb6\u9176\u4f53\u964d\u89e3\u7684\u9ad8\u6548\u5de5\u5177\u3002\u5728\u672a\u88c2\u89e3\u5f62\u5f0f\u4e0b\uff0cLysoLight Deep Red \u6216 LysoLight Green \u6ca1\u6709\u80cc\u666f\u8367\u5149\u3002\u53ea\u6709\u88ab\u6eb6\u9176\u4f53\u5185\u7684\u86cb\u767d\u9176 B \u88c2\u89e3\u540e\uff0c\u67d3\u6599\u624d\u4f1a\u53d8\u6210\u8367\u5149\uff0c\u4ece\u800c\u5206\u522b\u5bfc\u81f4 Cy5 \u6216 GPF\/FITC \u901a\u9053\u4e2d\u51fa\u73b0\u660e\u4eae\u7684\u8367\u5149\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"945\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224602@2x-1024x945.png\" alt=\"\" class=\"wp-image-1496\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224602@2x-1024x945.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224602@2x-300x277.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224602@2x-768x709.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224602@2x.png 1040w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 6 LysoLight Deep Red \uff08\u8d27\u53f7L36001\uff09\u6216 LysoLight green \uff08\u8d27\u53f7L36005\uff09\u4e0e\u897f\u59a5\u6614\u5355\u6297\uff08\u6216\u540c\u79cd\u578b\u5bf9\u7167\uff09\u7ed3\u5408\uff0c\u5e76\u4e0e EGFR+ \u4eba\u80ba\u80bf\u7624\u7403\u72b6\u4f53\uff08HuLu051421\uff09\u4e00\u8d77\u5b75\u80b2 16 \u5c0f\u65f6\u3002\u63a5\u4e0b\u6765\u7528 Hoechst \u590d\u67d3\u80bf\u7624\u7403\u72b6\u4f53\u7ec6\u80de\uff0c\u5e76\u5728\u5171\u805a\u7126\u663e\u5fae\u955c\u4e0a\u6210\u50cf\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-04-\u4f7f\u7528\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\u4f18\u5316\u60a8\u7684-adc\"><strong>04<\/strong> <strong>\u4f7f\u7528\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\u4f18\u5316\u60a8\u7684 ADC<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48\u8981\u4f7f\u7528\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\">\u4e3a\u4ec0\u4e48\u8981\u4f7f\u7528\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\uff1f<\/h3>\n\n\n\n<p>\u786e\u8ba4\u7ed3\u5408\u3001\u5185\u5316\u548c\u6eb6\u9176\u4f53\u964d\u89e3\u540e\uff0c\u6700\u540e\u4e00\u6b65\u662f\u4f18\u5316\u6297\u4f53\u6807\u8bb0\u8fc7\u7a0b\uff0c\u4ee5\u786e\u4fdd\u4e00\u81f4\u4e14\u53ef\u91cd\u590d\u7684\u7ed3\u679c\u3002\u4f18\u5316\u6d89\u53ca\u5fae\u8c03\u6807\u8bb0\u6761\u4ef6\u4ee5\u8fbe\u5230\u6240\u9700\u7684DOL (Degree of Labeling)\uff0c\u540c\u65f6\u4fdd\u7559\u6297\u539f\u7ed3\u5408\u4f4d\u70b9\u5e76\u7ef4\u6301\u6297\u4f53\u529f\u80fd\u3002\u6b64\u6b65\u9aa4\u5bf9\u4e8e\u751f\u4ea7\u9ad8\u8d28\u91cf ADC \u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7528\u4e8e\u53ef\u91cd\u590d-\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\u7684-siteclick-\u8bd5\u5242\">\u7528\u4e8e\u53ef\u91cd\u590d\u3001\u4f4d\u70b9\u7279\u5f02\u6027\u6807\u8bb0\u7684 SiteClick \u8bd5\u5242<\/h3>\n\n\n\n<p>Invitrogen\u2122 SiteClick\u2122 \u6297\u4f53\u6807\u8bb0\u6280\u672f\u53ef\u5b9e\u73b0\u8367\u5149\u67d3\u6599\u6216\u6bd2\u7d20\u7684\u4f4d\u70b9\u7279\u5f02\u6027\u7ed3\u5408\uff0c\u786e\u4fdd\u6297\u4f53 Fc \u90e8\u5206\u7684\u6807\u8bb0\u4e00\u81f4\u3002Invitrogen SiteClick \u6297\u4f53\u53e0\u6c2e\u4fee\u9970\u8bd5\u5242\u76d2\u4f7f\u7528\u9176\u901a\u8fc7\u53e0\u6c2e\u90e8\u5206\u7279\u5f02\u6027\u4fee\u9970\u6297\u4f53\u7684\u78b3\u6c34\u5316\u5408\u7269\u7ed3\u6784\u57df\u3002\u901a\u8fc7\u65e0\u94dc\u70b9\u51fb\u5316\u5b66\uff0c\u591a\u79cd sDIBO \u6216 DBCO \u7094\u70c3\u6807\u8bb0\u7269\u53ef\u5728\u5b75\u80b2\u6b65\u9aa4\u8fdb\u884c\u7ed3\u5408\u3002\u4f8b\u5982\uff0c\u5c06 pHrodo Red sDIBO\u901a\u8fc7\u70b9\u51fb\u5316\u5b66\u53cd\u5e94\u52a0\u5230\u53e0\u6c2e\u4fee\u9970\u7684\u66f2\u59a5\u73e0\u5355\u6297\u4e0a\uff0c\u4ee5\u8bc4\u4f30 SKBR3 \u7403\u72b6\u4f53\u4e2d\u7684\u5185\u5316\u60c5\u51b5\uff08\u56fe8\uff09<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-siteclick-\u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\"><strong>SiteClick \u8bd5\u5242\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4f4d\u70b9\u7279\u5f02\u6027\u7ed3\u5408<\/li>\n\n\n\n<li>\u7a33\u5b9a\uff1aDOL\u4e00\u81f4<\/li>\n\n\n\n<li>\u4fdd\u7559\u6297\u4f53\u529f\u80fd\uff1a\u4fdd\u7559\u6297\u539f\u7ed3\u5408\u4f4d\u70b9\u4ee5\u7ef4\u6301\u6297\u4f53\u529f\u80fd<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1020\" height=\"280\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224643@2x.png\" alt=\"\" class=\"wp-image-1497\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224643@2x.png 1020w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224643@2x-300x82.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224643@2x-768x211.png 768w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/figure>\n\n\n\n<p>\u56fe7. SiteClick \u4fee\u9970\u8bd5\u5242\u76d2\u91c7\u7528\u4f4d\u70b9\u7279\u5f02\u6027\u6cd5\uff0c\u5229\u7528\u03b2-\u534a\u4e73\u7cd6\u82f7\u9176\u548c\u03b2-1,4-\u534a\u4e73\u7cd6\u57fa\u8f6c\u79fb\u9176\u4fee\u9970\u78b3\u6c34\u5316\u5408\u7269\u7ed3\u6784\u57df\uff0c\u7136\u540e\u5c06\u53e0\u6c2e\u5316\u7269\u4fee\u9970\u7684\u7cd6\u9644\u7740\u5728 IgG \u6297\u4f53\u7684\u91cd\u94fe\u4e0a\u3002\u7531\u4e8e\u4fee\u9970\u53ea\u53d1\u751f\u5728\u91cd\u94fe\u7684 Fc \u90e8\u5206\uff0c\u56e0\u6b64\u6807\u8bb0\u7684\u4f4d\u7f6e\u548cDOL\u975e\u5e38\u4e00\u81f4\uff0c\u6297\u539f\u7ed3\u5408\u7ed3\u6784\u57df\u4fdd\u6301\u4e0d\u53d8\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"816\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224650@2x-1024x816.png\" alt=\"\" class=\"wp-image-1498\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224650@2x-1024x816.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224650@2x-300x239.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224650@2x-768x612.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224650@2x.png 1026w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u56fe 8. SKBR3 \u7403\u72b6\u4f53\u7528 pHrodo \u5076\u8054\u6297\u764c\u836f\u7269\uff08\u5e26\u6709 MMAE\u7684\u66f2\u59a5\u73e0\u5355\u6297\uff09\u548c CellEvent Caspase 3\/7Green\uff08\u8d27\u53f7C10423\uff09\u6807\u8bb0\u3002<\/p>\n\n\n\n<p>\u53c2\u8003\u6587\u732e<\/p>\n\n\n\n<p>Fu, Z., Li, S., Han, S. et al. Antibody drug conjugate: the \u201cbiological missile\u201d for targeted cancer therapy. Sig Transduct Target Ther 7, 93 (2022). https:\/\/doi.org\/10.1038\/s41392-022-00947-7<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4e3a\u4ec0\u4e48\u7814\u7a76\u6297\u4f53\u5076\u8054\u836f\u7269\uff1f \u6297\u4f53\u5076\u8054\u836f\u7269&nbsp;(Antibody Drug Conjugates, ADC<\/p>\n","protected":false},"author":1852,"featured_media":1491,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[27],"division":[9],"class_list":{"0":"post-1489","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-adc","9":"division-bid","10":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177\" \/>\n<meta property=\"og:description\" content=\"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-03T06:43:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1036\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\\\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177\",\"datePublished\":\"2026-04-03T06:43:37+00:00\",\"dateModified\":\"2026-04-22T21:59:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/\"},\"wordCount\":240,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-224349@2x.png\",\"keywords\":[\"ADC\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/\",\"name\":\"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\\\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-224349@2x.png\",\"datePublished\":\"2026-04-03T06:43:37+00:00\",\"dateModified\":\"2026-04-22T21:59:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-224349@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260325-224349@2x.png\",\"width\":1036,\"height\":450},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/adc-research-tool\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\\\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/","og_locale":"zh_CN","og_type":"article","og_title":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177","og_description":"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-04-03T06:43:37+00:00","article_modified_time":"2026-04-22T21:59:23+00:00","og_image":[{"width":1036,"height":450,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/adc-research-tool\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177","datePublished":"2026-04-03T06:43:37+00:00","dateModified":"2026-04-22T21:59:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/adc-research-tool\/"},"wordCount":240,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png","keywords":["ADC"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/adc-research-tool\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/","name":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png","datePublished":"2026-04-03T06:43:37+00:00","dateModified":"2026-04-22T21:59:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u8d5b\u9ed8\u98de\u5f00\u53d1\u4e86\u4e00\u7cfb\u5217\u521b\u65b0\u578bADC\u7814\u7a76\u5de5\u5177\uff0c\u53ef\u5b9e\u73b0\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u9274\u5b9a\uff0c\u9002\u7528\u4e8e\u591a\u79cd\u6837\u54c1\u7c7b\u578b\uff0c\u540c\u65f6\u517c\u5bb9\u5404\u4e2a\u5e73\u53f0\uff0c\u5305\u62ec\u6d41\u5f0f\u7ec6\u80de\u672f\u3001\u9ad8\u5185\u6db5\u6210\u50cf\u548c\u6d3b\u7ec6\u80de\u6210\u50cf\u7cfb\u7edf\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x.png","width":1036,"height":450},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/adc-research-tool\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u3010\u6297\u4f53\u5076\u8054\u836f\u7269\/ADC\u3011\u7b5b\u9009\u4e0e\u9274\u5b9a\u5de5\u5177"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":27,"label":"ADC"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260325-224349@2x-1024x445.png",760,330,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":27,"name":"ADC","slug":"adc","term_group":0,"term_taxonomy_id":27,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1489"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1489\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1491"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1489"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1489"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1489"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}