{"id":1750,"date":"2026-04-20T01:41:31","date_gmt":"2026-04-20T01:41:31","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1750"},"modified":"2026-04-22T21:59:21","modified_gmt":"2026-04-22T21:59:21","slug":"ftir-in-specialty-gas-production-from-purity-verification-to-process-insights","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/","title":{"rendered":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-\u5f15\u8a00\"><strong>\u5f15\u8a00<\/strong><\/h2>\n\n\n\n<p>\u7279\u79cd\u6c14\u4f53\u5bf9\u4e8e\u534a\u5bfc\u4f53\u5236\u9020\u3001\u6e05\u6d01\u80fd\u6e90\u751f\u4ea7\u3001\u5148\u8fdb\u6750\u6599\u52a0\u5de5\u548c\u7535\u5b50\u5236\u9020\u7b49\u5404\u884c\u4e1a\u7684\u5148\u8fdb\u5236\u9020\u81f3\u5173\u91cd\u8981\u3002\u968f\u7740\u8fd9\u4e9b\u884c\u4e1a\u7684\u53d1\u5c55\uff0c\u6c14\u4f53\u7eaf\u5ea6\u8981\u6c42\u4e0d\u65ad\u63d0\u9ad8\uff0c\u901a\u5e38\u8fbe\u5230\u5341\u4ebf\u5206\u4e4b\u4e00\u751a\u81f3\u4e07\u4ebf\u5206\u4e4b\u4e00\u7684\u6c34\u5e73\u3002\u540c\u65f6\uff0c\u5404\u7ec4\u7ec7\u9762\u4e34\u7740\u63d0\u5347\u53ef\u6301\u7eed\u6027\u3001\u786e\u4fdd\u5408\u89c4\u4ee5\u53ca\u7ef4\u62a4\u4f9b\u5e94\u94fe\u97e7\u6027\u7684\u538b\u529b\u3002<\/p>\n\n\n\n<p>\u4e3a\u6ee1\u8db3\u4e0a\u8ff0\u9700\u6c42\uff0cFTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\uff08\u5c24\u5176\u662f\u5149\u5b66\u589e\u5f3a\u578bFTIR\uff0cOE-FTIR\uff09\u5df2\u6210\u4e3a\u4e00\u79cd\u91cd\u8981\u7684\u5206\u6790\u624b\u6bb5\u3002\u8be5\u6280\u672f\u80fd\u591f\u5728\u8d85\u75d5\u91cf\u6c34\u5e73\u4e0b\u5b9e\u73b0\u5feb\u901f\u3001\u591a\u7ec4\u5206\u5206\u6790\uff0c\u4f7f\u6c14\u4f53\u76d1\u6d4b\u4ece\u79bb\u7ebf\u9a8c\u8bc1\u8f6c\u5411\u8fde\u7eed\u3001\u5b9e\u65f6\u7684\u8fc7\u7a0b\u76d1\u63a7\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48ftir\u6280\u672f\u5728\u6269\u5c55\u7279\u79cd\u6c14\u4f53\u5206\u6790\u80fd\u529b\u4e2d\u5177\u6709\u6838\u5fc3\u4f5c\u7528\"><strong>\u4e3a\u4ec0\u4e48FTIR\u6280\u672f\u5728\u6269\u5c55\u7279\u79cd\u6c14\u4f53\u5206\u6790\u80fd\u529b\u4e2d\u5177\u6709\u6838\u5fc3\u4f5c\u7528<a><\/a><\/strong><strong><\/strong><\/h2>\n\n\n\n<p>\u5085\u91cc\u53f6\u53d8\u6362\u7ea2\u5916\uff08FTIR\uff09\u5149\u8c31\u6280\u672f\u975e\u5e38\u9002\u7528\u4e8e\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u548c\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\uff0c\u56e0\u4e3a\u5b83\u80fd\u5728\u4e00\u6b21\u6d4b\u91cf\u4e2d\u540c\u65f6\u68c0\u6d4b\u591a\u79cd\u6c14\u4f53\u7ec4\u5206\u3002\u4e0e\u6c14\u76f8\u8272\u8c31\uff08GC\uff09\u9010\u4e2a\u76ee\u6807\u6216\u4f9d\u6b21\u76d1\u6d4b\u4e0d\u540c\uff0c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fourier-transform-infrared-spectroscopy\/instruments.html?icid=CAD_blog_materials_2026April#gas-analyzers\"><u>FTIR\u5149\u8c31\u4eea<\/u><\/a>\u80fd\u591f\u5206\u6790\u5b8c\u6574\u7684\u7ea2\u5916\u5149\u8c31\u3002\u8fd9\u4f7f\u5f97\u5bf9\u590d\u6742\u6c14\u4f53\u4f53\u7cfb\u4e2d\u7684\u6c34\u5206\u3001\u78b3\u6c22\u5316\u5408\u7269\u3001\u9178\u6027\u6c14\u4f53\u53ca\u5176\u4ed6\u6742\u8d28\u8fdb\u884c\u6301\u7eed\u76d1\u6d4b\u6210\u4e3a\u53ef\u80fd\u3002<\/p>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fourier-transform-infrared-spectroscopy\/instruments\/max-ir-ftir-gas-analyzer.html?icid=CAD_blog_materials_2026April\"><u>OE-FTIR\u5206\u6790\u4eea<\/u><\/a>\u88ab\u8bbe\u8ba1\u7528\u4e8e\u9700\u8981\u5feb\u901f\u54cd\u5e94\u65f6\u95f4\u3001\u4f4e\u68c0\u6d4b\u9650\u548c\u7a33\u5b9a\u957f\u671f\u6027\u80fd\u7684\u5e94\u7528\u3002\u8fd9\u4e9bOE-FTIR\u7cfb\u7edf\u63d0\u4f9b\u4e86\u591a\u9879\u4f18\u52bf\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5feb\u901f\u5206\u6790\u4ee5\u6355\u6349\u77ac\u65f6\u6c61\u67d3\u4e8b\u4ef6<\/li>\n\n\n\n<li>\u8d85\u4f4e\u68c0\u6d4b\u9650\uff0c\u9002\u7528\u4e8e\u9ad8\u7eaf\u5ea6\u548c\u7535\u5b50\u7ea7\u6c14\u4f53<\/li>\n\n\n\n<li>\u5e7f\u6cdb\u7684\u5316\u5b66\u8986\u76d6\u8303\u56f4\uff0c\u65e0\u9700\u91cd\u65b0\u6821\u51c6<\/li>\n\n\n\n<li>\u6301\u7eed\u76d1\u6d4b\u4ee5\u652f\u6301\u5b9e\u65f6\u8fc7\u7a0b\u63a7\u5236<\/li>\n<\/ul>\n\n\n\n<p>\u7531\u4e8e\u8fd9\u4e9b\u80fd\u529b\uff0cFTIR\u6280\u672f\u8d8a\u6765\u8d8a\u591a\u5730\u76f4\u63a5\u5d4c\u5165\u5230\u5de5\u4e1a\u5de5\u4f5c\u6d41\u7a0b\u4e2d\uff0c\u4f7f\u5f00\u53d1\u5468\u671f\u66f4\u5feb\u3001\u7ed3\u679c\u66f4\u53ef\u9760\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5728\u7279\u79cd\u6c14\u4f53\u4ef7\u503c\u94fe\u4e2d\u5d4c\u5165FTIR\u6c14\u4f53\u5206\u6790<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>FTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u652f\u6301\u6574\u4e2a\u7279\u79cd\u6c14\u4f53\u751f\u547d\u5468\u671f\u7684\u8d28\u91cf\u4fdd\u969c\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u539f\u6599\u53ca\u8fdb\u6599\u6c14\u4f53\u9a8c\u8bc1\uff1a<\/strong>\u4e0a\u6e38FTIR\u5206\u6790\u53ef\u5728\u51c0\u5316\u524d\u9a8c\u8bc1\u8fdb\u6599\u539f\u6750\u6599\uff0c\u8bc6\u522b\u53ef\u80fd\u5f71\u54cd\u4e0b\u6e38\u5de5\u827a\u6216\u9650\u5236\u6027\u80fd\u7684\u6c34\u5206\u3001\u6c27\u6c14\u548c\u5fae\u91cf\u78b3\u6c22\u5316\u5408\u7269\u3002<\/li>\n\n\n\n<li><strong>\u7eaf\u5316\u548c\u751f\u4ea7\u76d1\u63a7\uff1a<\/strong>\u5728\u7eaf\u5316\u8fc7\u7a0b\u4e2d\uff0cFTIR\u5206\u6790\u4eea\u88ab\u653e\u7f6e\u5728\u5173\u952e\u63a7\u5236\u70b9\u2014\u2014\u5982\u67f1\u5b50\u3001\u5438\u9644\u5668\u6216\u7eaf\u5316\u5668\u7684\u524d\u540e\u2014\u2014\u4ee5\u63d0\u4f9b\u6301\u7eed\u53cd\u9988\u3002\u5b9e\u65f6\u6d4b\u91cf\u4f7f\u64cd\u4f5c\u5458\u80fd\u591f\u53ca\u65e9\u53d1\u73b0\u7a81\u7834\u4e8b\u4ef6\u6216\u7eaf\u5316\u5668\u6027\u80fd\u4e0b\u964d\uff0c\u4ece\u800c\u51cf\u5c11\u6d6a\u8d39\u5e76\u907f\u514d\u4e0d\u5408\u683c\u4ea7\u54c1\u7684\u4ea7\u751f\u3002<\/li>\n\n\n\n<li><strong>\u6df7\u5408\u7269\u5236\u5907\u4e0e\u8ba1\u91cf\uff1a<\/strong>\u5728\u6821\u51c6\u6c14\u4f53\u548c\u7279\u79cd\u6df7\u5408\u7269\u5236\u5907\u4e2d\uff0cFTIR\u5206\u6790\u6709\u52a9\u4e8e\u53ef\u8ffd\u6eaf\u6027\u548c\u4e0d\u786e\u5b9a\u5ea6\u7ba1\u7406\u3002\u5728\u4e00\u6b21\u5149\u8c31\u91c7\u96c6\u8fc7\u7a0b\u4e2d\u6d4b\u91cf\u6240\u6709\u7ec4\u5206\uff0c\u53ef\u6700\u5927\u9650\u5ea6\u51cf\u5c11\u4e0d\u540c\u65b9\u6cd5\u95f4\u7684\u53d8\u5f02\uff0c\u5e76\u751f\u6210\u53ef\u8ffd\u6eaf\u4e14\u6709\u636e\u53ef\u4f9d\u7684\u6210\u5206\u6570\u636e\u3002<\/li>\n\n\n\n<li><strong>\u94a2\u74f6\u5145\u88c5\u4e0e\u8d28\u91cf\u4fdd\u8bc1\uff1a<\/strong>\u5728\u4ea7\u54c1\u6279\u51c6\u548c\u53d1\u8d27\u524d\uff0cFTIR\u5206\u6790\u53ef\u786e\u8ba4\u6c34\u5206\u548c\u5173\u952e\u6742\u8d28\uff0c\u5c24\u5176\u9002\u7528\u4e8e\u534a\u5bfc\u4f53\u5236\u9020\u4e2d\u4f7f\u7528\u7684\u8d85\u9ad8\u7eaf\u6c14\u4f53\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6d88\u9664\u5206\u6790\u76f2\u533a\"><strong>\u6d88\u9664\u5206\u6790\u76f2\u533a<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>\u5728\u4f7f\u7528\u70b9\u7b49\u73af\u8282\u5b58\u5728\u7684\u5206\u6790\u76f2\u533a\uff0c\u53ef\u80fd\u5bf9\u5de5\u827a\u7a33\u5b9a\u6027\u548c\u4ea7\u7387\u4ea7\u751f\u5f71\u54cd\u3002\u6279\u6b21\u68c0\u6d4b\u867d\u7136\u53ef\u4ee5\u5728\u53d7\u63a7\u6761\u4ef6\u4e0b\u5bf9\u6c14\u4f53\u89c4\u683c\u8fdb\u884c\u9a8c\u8bc1\uff0c\u4f46\u65e0\u6cd5\u6355\u6349\u77ed\u65f6\u4e8b\u4ef6\u4e2d\u53ef\u80fd\u51fa\u73b0\u7684\u6c61\u67d3\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6c14\u4f53\u5207\u6362<\/li>\n\n\n\n<li>\u5439\u626b\u64cd\u4f5c<\/li>\n\n\n\n<li>\u8bbe\u5907\u542f\u52a8\u6216\u7ef4\u62a4<\/li>\n<\/ul>\n\n\n\n<p>FTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u53ef\u5b9e\u73b0\u9ad8\u901f\u3001\u8fde\u7eed\u76d1\u6d4b\uff0c\u4ece\u800c\u4f7f\u64cd\u4f5c\u4eba\u5458\u80fd\u591f\u6355\u6349\u5e72\u6270\u5de5\u827a\u6216\u5ef6\u7f13\u5f00\u53d1\u8fdb\u5ea6\u7684\u77ac\u6001\u5f02\u5e38\u3002\u5728\u534a\u5bfc\u4f53\u5236\u9020\u4e2d\uff0c\u6742\u8d28\u89c4\u683c\u751a\u81f3\u53ef\u8fbe\u4e07\u4ebf\u5206\u4e4b\u4e00\uff08ppt\uff09\u7ea7\u522b\uff0c\u5373\u4f7f\u662f\u77ed\u65f6\u6c61\u67d3\u4e8b\u4ef6\u4e5f\u53ef\u80fd\u5f71\u54cd\u4ea7\u91cf\u548c\u8bbe\u5907\u6027\u80fd\u3002<\/p>\n\n\n\n<p>\u901a\u8fc7\u5c06FTIR\u5206\u6790\u4eea\u90e8\u7f72\u5728\u66f4\u9760\u8fd1\u6c14\u4f53\u67dc\u548c\u8bbe\u5907\u5165\u53e3\u7684\u4f4d\u7f6e\uff0c\u4f01\u4e1a\u80fd\u591f\u76f4\u63a5\u4e86\u89e3\u5b9e\u9645\u8fd0\u884c\u72b6\u51b5\uff0c\u5e76\u964d\u4f4e\u56e0\u6c61\u67d3\u5bfc\u81f4\u4ea7\u91cf\u635f\u5931\u7684\u98ce\u9669\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u81ea\u4fe1\u5730\u6d4b\u91cf\u6c14\u4f53\u7eaf\u5ea6\u548c\u8d85\u75d5\u91cf\u6742\u8d28\"><strong>\u81ea\u4fe1\u5730\u6d4b\u91cf\u6c14\u4f53\u7eaf\u5ea6\u548c\u8d85\u75d5\u91cf\u6742\u8d28<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>\u8fd9\u4e9b\u80fd\u529b\u7ed3\u5408\u8d77\u6765\uff0c\u4f7fFTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5728\u4e25\u82db\u73af\u5883\u4e2d\u63d0\u4f9b\u51c6\u786e\u4e14\u53ef\u64cd\u4f5c\u7684\u6570\u636e\u3002<\/p>\n\n\n\n<p>\u968f\u7740\u7eaf\u5ea6\u8981\u6c42\u4e0d\u65ad\u63d0\u9ad8\uff0c\u7279\u79cd\u6c14\u4f53\u5206\u6790\u9762\u4e34\u8bf8\u591a\u6280\u672f\u6311\u6218\uff0c\u800cFTIR\u6280\u672f\u80fd\u591f\u6709\u6548\u5e94\u5bf9\u8fd9\u4e9b\u6311\u6218\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u591a\u7ec4\u5206\u6d4b\u91cf\uff1a<\/strong>\u7279\u79cd\u6c14\u4f53\u5e94\u7528\u901a\u5e38\u9700\u8981\u540c\u65f6\u6d4b\u91cf\u6c34\u5206\u3001\u9178\u6027\u6c14\u4f53\u3001\u786b\u5316\u7269\u4ee5\u53ca\u8f7b\u70c3\u7b49\u591a\u79cd\u7ec4\u5206\u3002FTIR\u5149\u8c31\u6280\u672f\u53ef\u5728\u5355\u4e00\u5206\u6790\u5e73\u53f0\u4e0a\u5b9e\u73b0\u5bf9\u591a\u79cd\u5316\u5b66\u7ec4\u5206\u7684\u5e7f\u6cdb\u8986\u76d6\u3002<\/li>\n\n\n\n<li><strong>\u53cd\u5e94\u6027\u548c\u6613\u5438\u9644\u6c14\u4f53\uff1a<\/strong>\u5728\u8d85\u75d5\u91cf\u6c34\u5e73\u4e0b\uff0c\u53cd\u5e94\u6027\u6c14\u4f53\u53ef\u80fd\u4e0e\u91c7\u6837\u7cfb\u7edf\u8868\u9762\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\uff0c\u5bfc\u81f4\u5438\u9644\u3001\u89e3\u5438\u6216\u54cd\u5e94\u5ef6\u8fdf\u3002\u8d85\u75d5\u91cf\u6d4b\u91cf\u7684\u5b9e\u73b0\u4e0d\u4ec5\u4f9d\u8d56\u4e8e\u5206\u6790\u4eea\u672c\u8eab\uff0c\u8fd8\u9ad8\u5ea6\u4f9d\u8d56\u4e8e\u91c7\u6837\u7cfb\u7edf\u7684\u8bbe\u8ba1\u3002\u91c7\u7528\u60f0\u6027\u6750\u6599\u3001\u6700\u5c0f\u5316\u6b7b\u4f53\u79ef\u3001\u4f18\u5316\u6e29\u5ea6\u63a7\u5236\u4ee5\u53ca\u5408\u7406\u7684\u6d41\u901f\u7ba1\u7406\uff0c\u5bf9\u4e8e\u5b9e\u73b0\u5feb\u901f\u54cd\u5e94\u548c\u826f\u597d\u91cd\u590d\u6027\u81f3\u5173\u91cd\u8981\u3002\u5728\u6b64\u57fa\u7840\u4e0a\uff0cFTIR\u6280\u672f\u80fd\u591f\u5bf9\u8fd9\u4e9b\u96be\u5904\u7406\u6c14\u4f53\u5b9e\u73b0\u9ad8\u7cbe\u5ea6\u68c0\u6d4b\u3002<\/li>\n\n\n\n<li><strong>\u901f\u5ea6\u4e0e\u957f\u671f\u7a33\u5b9a\u6027\uff1a<\/strong>\u4e3a\u652f\u6301\u9ad8\u6c34\u5e73\u7684\u8fc7\u7a0b\u63a7\u5236\uff0c\u5206\u6790\u7cfb\u7edf\u9700\u8981\u5728\u4fdd\u6301\u4f4e\u6f02\u79fb\u548c\u9ad8\u7cfb\u7edf\u53ef\u7528\u6027\u7684\u540c\u65f6\uff0c\u5b9e\u73b0\u5feb\u901f\u54cd\u5e94\u3002\u7a33\u5b9a\u7684\u5149\u5b66\u7ed3\u6784\u548c\u81ea\u52a8\u8bca\u65ad\u529f\u80fd\u5bf9\u4e8e\u5b9e\u73b0\u6301\u7eed\u3001\u53ef\u9760\u7684\u6d4b\u91cf\u81f3\u5173\u91cd\u8981\u3002<\/li>\n<\/ul>\n\n\n\n<p>\u7efc\u5408\u6765\u770b\uff0c\u8fd9\u4e9b\u80fd\u529b\u4f7fFTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5728\u4e25\u82db\u5de5\u51b5\u4e0b\u63d0\u4f9b\u51c6\u786e\u4e14\u5177\u6709\u51b3\u7b56\u4ef7\u503c\u7684\u6570\u636e\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u652f\u6301\u53ef\u6301\u7eed\u8fd0\u8425\"><strong>\u652f\u6301\u53ef\u6301\u7eed\u8fd0\u8425<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>\u53ef\u6301\u7eed\u6027\u4e0e\u7279\u79cd\u6c14\u4f53\u884c\u4e1a\u7684\u521b\u65b0\u65e5\u76ca\u7d27\u5bc6\u76f8\u8fde\u3002\u51c6\u786e\u7684\u6c14\u4f53\u6d4b\u91cf\u4f7f\u7ec4\u7ec7\u80fd\u591f\u63a8\u8fdb\u73af\u5883\u76ee\u6807\uff0c\u540c\u65f6\u4fdd\u6301\u6027\u80fd\u548c\u53ef\u9760\u6027\u3002FTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u901a\u8fc7\u4ee5\u4e0b\u65b9\u5f0f\u652f\u6301\u53ef\u6301\u7eed\u53d1\u5c55\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9a8c\u8bc1\u7535\u5b50\u5236\u9020\u4e2d\u7684\u4f4e\u6392\u653e\u5de5\u827a<\/li>\n\n\n\n<li>\u76d1\u6d4b\u5305\u62ec\u6c22\u6c14\u3001\u6c28\u548c\u7532\u9187\u5728\u5185\u7684\u66ff\u4ee3\u71c3\u6599<\/li>\n\n\n\n<li>\u63d0\u5347\u5bf9\u5177\u6709\u9ad8\u5168\u7403\u53d8\u6696\u6f5c\u80fd\u6c14\u4f53\u7684\u56de\u6536\u4e0e\u518d\u5229\u7528\u64cd\u4f5c<\/li>\n<\/ul>\n\n\n\n<p>\u53ef\u9760\u3001\u51c6\u786e\u7684\u6d4b\u91cf\u5bf9\u4e8e\u6392\u653e\u62a5\u544a\u3001\u6cd5\u89c4\u9075\u4ece\u4ee5\u53ca\u9a8c\u8bc1\u5de5\u827a\u6539\u8fdb\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u8d85\u8d8a\u8d28\u91cf\u63a7\u5236\uff1a\u6301\u7eed\u8fc7\u7a0b\u6d1e\u5bdf\u529b<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>FTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u7684\u4f5c\u7528\u5df2\u8fdc\u8fdc\u8d85\u8d8a\u4f20\u7edf\u8d28\u91cf\u63a7\u5236\u3002\u5982\u4eca\uff0c\u5b83\u8d8a\u6765\u8d8a\u88ab\u89c6\u4e3a\u5e2e\u52a9\u7ec4\u7ec7\u5b9e\u73b0\u4ee5\u4e0b\u76ee\u6807\u7684\u91cd\u8981\u5de5\u5177\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u964d\u4f4e\u8fd0\u8425\u548c\u5b89\u5168\u98ce\u9669\uff0c\u901a\u8fc7\u6301\u7eed\u76d1\u6d4b<\/li>\n\n\n\n<li>\u52a0\u5feb\u8d44\u683c\u8ba4\u8bc1\u548c\u4ea7\u54c1\u53d1\u5e03\u7684\u65f6\u95f4<\/li>\n\n\n\n<li>\u901a\u8fc7\u4e00\u81f4\u4e14\u53ef\u8fa9\u62a4\u7684\u6c14\u4f53\u7eaf\u5ea6\u5b9e\u73b0\u5dee\u5f02\u5316<\/li>\n\n\n\n<li>\u5728\u4f9b\u5e94\u94fe\u4e2d\u5efa\u7acb\u957f\u671f\u4fe1\u4efb<\/li>\n<\/ul>\n\n\n\n<p>\u901a\u8fc7\u4ece\u6e90\u5934\u5230\u4f7f\u7528\u70b9\u63d0\u4f9b\u6301\u7eed\u3001\u53ef\u8ffd\u6eaf\u7684\u7eaf\u5ea6\u6570\u636e\uff0cFTIR\u5206\u6790\u65e2\u63a8\u52a8\u6280\u672f\u8fdb\u6b65\uff0c\u4e5f\u589e\u5f3a\u957f\u671f\u97e7\u6027\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u8bba\"><strong>\u7ed3\u8bba<\/strong><strong><\/strong><\/h2>\n\n\n\n<p>\u968f\u7740\u5404\u884c\u4e1a\u4e0d\u65ad\u7a81\u7834\u6027\u80fd\u3001\u53ef\u6301\u7eed\u6027\u548c\u7cbe\u786e\u6027\u7684\u8fb9\u754c\uff0cFTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u5df2\u6210\u4e3a\u63a8\u52a8\u6280\u672f\u8fdb\u6b65\u7684\u91cd\u8981\u5de5\u5177\u3002\u51ed\u501f\u5feb\u901f\u3001\u591a\u7ec4\u5206\u3001\u8d85\u75d5\u91cf\u68c0\u6d4b\uff0cOE-FTIR\u6280\u672f\u6709\u52a9\u4e8e\u6d88\u9664\u5206\u6790\u76f2\u533a\uff0c\u652f\u6301\u53ef\u6301\u7eed\u53d1\u5c55\uff0c\u5e76\u4fdd\u969c\u7279\u79cd\u6c14\u4f53\u4ef7\u503c\u94fe\u7684\u6301\u7eed\u5408\u89c4\u3002<\/p>\n\n\n\n<p>\u5728\u4e00\u4e2a\u6210\u529f\u4f9d\u8d56\u4e8e\u7cbe\u786e\u4e0e\u53ef\u9760\u6027\u7684\u73af\u5883\u4e2d\uff0cFTIR\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\u662f\u8fdb\u6b65\u7684\u91cd\u8981\u57fa\u7840\u3002<br><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5e38\u89c1\u95ee\u9898\uff1a<\/strong><strong><\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u54ea\u4e9b\u884c\u4e1a\u53ef\u4ee5\u53d7\u76ca\u4e8eFTIR\u6c14\u4f53\u5206\u6790\uff1f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u9664\u4e86\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\uff0c\u4efb\u4f55\u9700\u8981\u7cbe\u786e\u6c14\u4f53\u6210\u5206\u548c\u4e00\u81f4\u6027\u7684\u5e94\u7528\u884c\u4e1a\u90fd\u53ef\u4ee5\u4eceFTIR\u6c14\u4f53\u5206\u6790\u4e2d\u53d7\u76ca\u3002\u8fd9\u5305\u62ec\u4f46\u4e0d\u9650\u4e8e\u5efa\u7b51\u548c\u710a\u63a5\uff1b\u534a\u5bfc\u4f53\u5236\u9020\u6216\u589e\u6750\u5236\u9020\uff1b\u66ff\u4ee3\u71c3\u6599\uff1b\u533b\u7597\u548c\u5b9e\u9a8c\u5ba4\u7528\u9014\uff1b\u73af\u5883\u76d1\u6d4b\u7b49\u3002<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>FTIR\u6c14\u4f53\u5206\u6790\u76f8\u6bd4\u6279\u91cf\u5206\u6790\u6709\u54ea\u4e9b\u4f18\u52bf\uff1f<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u7531\u4e8e\u6574\u4e2a\u7ea2\u5916\u5149\u8c31\u53ef\u4ee5\u5728\u51e0\u79d2\u949f\u5185\u83b7\u53d6\uff0cFTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u63d0\u4f9b\u8fde\u7eed\u6570\u636e\uff0c\u4f7f\u5f97\u53ef\u4ee5\u7acb\u5373\u8c03\u6574\u5de5\u827a\u4ee5\u6700\u5927\u5316\u6548\u7387\u3002FTIR\u6d4b\u91cf\u53ef\u539f\u4f4d\u8fdb\u884c\uff0c\u6837\u54c1\u51c6\u5907\u6781\u5c11\u751a\u81f3\u65e0\u9700\u51c6\u5907\u3002\u8fd9\u4f7f\u5f97\u5206\u6790\u8fc7\u7a0b\u6bd4\u4f20\u7edf\u8017\u65f6\u7684\u5b9e\u9a8c\u5ba4\u6279\u91cf\u5206\u6790\u66f4\u5feb\u901f\u3001\u66f4\u7075\u6d3b\u3002<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>FTIR\u6c14\u4f53\u5206\u6790\u4eea\u7684\u5178\u578b\u68c0\u6d4b\u9650\u662f\u591a\u5c11\uff1f<\/strong>\n<ul class=\"wp-block-list\">\n<li>FTIR\u7684\u68c0\u6d4b\u9650\u56e0\u6240\u91c7\u7528\u7684\u6280\u672f\u4e0d\u540c\u800c\u6709\u6240\u5dee\u5f02\u3002\u5bf9\u4e8e\u7279\u79cd\u6c14\u4f53\u5206\u6790\uff0c\u5176\u68c0\u6d4b\u9650\u901a\u5e38\u53ef\u8fbeppb\u751a\u81f3\u4e9appb\u6c34\u5e73\u3002\u91c7\u7528\u5149\u5b66\u589e\u5f3a\u578bFTIR\uff08OE-FTIR\uff09\u65f6\uff0c\u68c0\u6d4b\u80fd\u529b\u53ef\u8fdb\u4e00\u6b65\u63d0\u5347\u81f3ppt\uff0810\u207b\u00b9\u00b2\uff09\u7ea7\u522b\uff0c\u4ece\u800c\u6ee1\u8db3\u8d85\u9ad8\u7eaf\u6c14\u4f53\u5206\u6790\u7684\u9700\u6c42\u3002 <\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f15\u8a00 \u7279\u79cd\u6c14\u4f53\u5bf9\u4e8e\u534a\u5bfc\u4f53\u5236\u9020\u3001\u6e05\u6d01\u80fd\u6e90\u751f\u4ea7\u3001\u5148\u8fdb\u6750\u6599\u52a0\u5de5\u548c\u7535\u5b50\u5236\u9020\u7b49\u5404\u884c\u4e1a\u7684\u5148\u8fdb\u5236\u9020\u81f3\u5173\u91cd\u8981\u3002\u968f\u7740\u8fd9\u4e9b\u884c\u4e1a\u7684\u53d1<\/p>\n","protected":false},"author":1852,"featured_media":1754,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[51],"tags":[161,160,162,159],"division":[52],"class_list":{"0":"post-1750","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-51","8":"tag-ftir","9":"tag-160","10":"tag-162","11":"tag-159","12":"division-cad","13":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf\" \/>\n<meta property=\"og:description\" content=\"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-20T01:41:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:21+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"320\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf\",\"datePublished\":\"2026-04-20T01:41:31+00:00\",\"dateModified\":\"2026-04-22T21:59:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/\"},\"wordCount\":43,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg\",\"keywords\":[\"FTIR\u6c14\u4f53\u5206\u6790\",\"\u5de5\u4e1a\u6c14\u4f53\u5206\u6790\",\"\u6c14\u4f53\u5206\u6790\",\"\u7279\u79cd\u6c14\u4f53\"],\"articleSection\":[\"\u6750\u6599\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/\",\"name\":\"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg\",\"datePublished\":\"2026-04-20T01:41:31+00:00\",\"dateModified\":\"2026-04-22T21:59:21+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg\",\"width\":600,\"height\":320},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/","og_locale":"zh_CN","og_type":"article","og_title":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf","og_description":"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-04-20T01:41:31+00:00","article_modified_time":"2026-04-22T21:59:21+00:00","og_image":[{"width":600,"height":320,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf","datePublished":"2026-04-20T01:41:31+00:00","dateModified":"2026-04-22T21:59:21+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/"},"wordCount":43,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg","keywords":["FTIR\u6c14\u4f53\u5206\u6790","\u5de5\u4e1a\u6c14\u4f53\u5206\u6790","\u6c14\u4f53\u5206\u6790","\u7279\u79cd\u6c14\u4f53"],"articleSection":["\u6750\u6599\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/","name":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg","datePublished":"2026-04-20T01:41:31+00:00","dateModified":"2026-04-22T21:59:21+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"FTIR\u6c14\u4f53\u5206\u6790\u80fd\u591f\u5b9e\u73b0ppb\u7ea7\u751a\u81f3\u66f4\u4f4e\u6d53\u5ea6\u7684\u68c0\u6d4b\u80fd\u529b \uff0c\u540c\u65f6\u63d0\u4f9b\u5b9e\u65f6\u7684\u5de5\u827a\u76d1\u7ba1\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg","width":600,"height":320},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/ftir-in-specialty-gas-production-from-purity-verification-to-process-insights\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"FTIR\u5728\u7279\u79cd\u6c14\u4f53\u751f\u4ea7\u4e2d\u7684\u5e94\u7528\uff1a\u4ece\u7eaf\u5ea6\u9a8c\u8bc1\u5230\u8fc7\u7a0b\u6d1e\u5bdf"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":51,"label":"\u6750\u6599\u79d1\u5b66"}],"post_tag":[{"value":161,"label":"FTIR\u6c14\u4f53\u5206\u6790"},{"value":160,"label":"\u5de5\u4e1a\u6c14\u4f53\u5206\u6790"},{"value":162,"label":"\u6c14\u4f53\u5206\u6790"},{"value":159,"label":"\u7279\u79cd\u6c14\u4f53"}],"division":[{"value":52,"label":"CAD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/Specialty-Gases-iStock-2210904455-600-x-320-1.jpg",600,320,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":51,"name":"\u6750\u6599\u79d1\u5b66","slug":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":51,"taxonomy":"category","description":"","parent":0,"count":30,"filter":"raw","meta":[],"cat_ID":51,"category_count":30,"category_description":"","cat_name":"\u6750\u6599\u79d1\u5b66","category_nicename":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":161,"name":"FTIR\u6c14\u4f53\u5206\u6790","slug":"ftir%e6%b0%94%e4%bd%93%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":161,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":160,"name":"\u5de5\u4e1a\u6c14\u4f53\u5206\u6790","slug":"%e5%b7%a5%e4%b8%9a%e6%b0%94%e4%bd%93%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":160,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":162,"name":"\u6c14\u4f53\u5206\u6790","slug":"%e6%b0%94%e4%bd%93%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":162,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":159,"name":"\u7279\u79cd\u6c14\u4f53","slug":"%e7%89%b9%e7%a7%8d%e6%b0%94%e4%bd%93","term_group":0,"term_taxonomy_id":159,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1750"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1750\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1754"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1750"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}