{"id":1916,"date":"2026-05-20T03:42:57","date_gmt":"2026-05-20T03:42:57","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1916"},"modified":"2026-05-20T03:42:58","modified_gmt":"2026-05-20T03:42:58","slug":"olink-dermatitis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-dermatitis\/","title":{"rendered":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u524d\u5f80<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/brands\/olink-proteomics-protein-biomarker-analysis.html?icid=cn-blog-olink\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d5b\u9ed8\u98deOlink\u4e3b\u9875<\/a>&gt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u80cc\u666f\"><strong>\u7814\u7a76\u80cc\u666f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">12\u670826\u65e5\uff0c\u5f3a\u751f\u5ba3\u5e03\u5176\u9488\u5bf9\u4e2d\u5ea6\u81f3\u91cd\u5ea6\u7279\u5e94\u6027\u76ae\u708e\u7684\u53cc\u6297\u836f\u7269JNJ-5939\u4e34\u5e8aIIb\u671f\u7814\u7a76\u63d0\u524d\u7ec8\u6b62\uff0c\u518d\u6b21\u51f8\u663e\u4e86<strong>\u590d\u6742\u7cfb\u7edf\u6027\u75be\u75c5\u836f\u7269\u7684\u7814\u53d1\u6311\u6218<\/strong>\u3002\u901a\u8fc7\u52a8\u6001\u7684\u86cb\u767d\u53d8\u5316\u5168\u666f\u56fe\uff0c\u6709\u52a9\u4e8e\u63ed\u793a\u590d\u6742\u75be\u75c5\u7684\u751f\u7269\u5b66\u673a\u5236\uff0c\u8fdb\u4e00\u6b65\u4e86\u89e3\u836f\u7269\u5728\u4f53\u5185\u7684\u4f5c\u7528\uff0c\u5e76\u8bc6\u522b\u51fa\u9488\u5bf9\u7279\u5b9a\u836f\u7269\u7684\u6f5c\u5728\u5e94\u7b54\u8005\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u708e\u75c7\u6027\u76ae\u80a4\u75c5<\/strong>\u5f71\u54cd\u7740\u5168\u7403\u6570\u4ebf\u4eba\u3002\u8d8a\u6765\u8d8a\u591a\u7684\u7814\u7a76\u8868\u660e\uff0c\u708e\u75c7\u6027\u76ae\u80a4\u75c5<strong>\u662f\u5168\u8eab\u6027\u514d\u75ab\u7cfb\u7edf\u5931\u8c03\u5728\u76ae\u80a4\u4e0a\u7684\u8868\u73b0<\/strong>\u3002\u5c31\u50cf\u201c\u51b0\u5c71\u4e00\u89d2\u201d\uff0c\u76ae\u80a4\u7684\u75c7\u72b6\u53ef\u80fd\u4f34\u968f\u7740\u8840\u6db2\u4e2d\u770b\u4e0d\u89c1\u7684\u201c\u708e\u75c7\u98ce\u66b4\u201d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u7814\u7a76\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\uff0c<strong>\u5305\u62ec\u7279\u5e94\u6027\u76ae\u708e\uff08AD\uff09\uff0c\u6591\u79c3\uff08AA\uff09\uff0c\u5316\u8113\u6027\u6c57\u817a\u708e\uff08HS\uff09\uff0c\u94f6\u5c51\u75c5\u548c\u767d\u765c\u98ce<\/strong>\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u5f02\u5e38\uff0c\u5e76\u63a2\u7a76\u5176\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u98ce\u9669\u548c\u4ee3\u8c22\u7c7b\u75be\u75c5\u7b49\u7684\u5173\u8054\uff0c\u6765\u81ea\u7f8e\u56fd\u897f\u5948\u5c71\u4f0a\u574e\u533b\u5b66\u9662\u7684\u7814\u7a76\u56e2\u961f\u5f00\u5c55\u4e86\u4e00\u9879\u5927\u89c4\u6a21\u8840\u6db2\u86cb\u767d\u7ec4\u5b66\u7814\u7a76\u3002\u91c7\u7528<strong>Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0<\/strong>\uff0c\u5bf9\u76ae\u80a4\u75c5\u60a3\u8005\u8840\u6e05\u6837\u672c\u4e2d1472\u79cd\u4e0e\u514d\u75ab\uff0c\u5fc3\u8840\u7ba1\u76f8\u5173\u548c\u8986\u76d6\u4e3b\u8981\u751f\u7269\u5b66\u901a\u8def\u7684\u86cb\u767d\u8d28\u8fdb\u884c\u4e86\u5b9a\u91cf\u68c0\u6d4b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"516\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724761-1024x516.png\" alt=\"\" class=\"wp-image-1926\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724761-1024x516.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724761-300x151.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724761-768x387.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724761.png 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u60a3\u8005\u961f\u5217\"><strong>\u60a3\u8005\u961f\u5217<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7eb3\u5165\u4e8638\u540d\u4e2d\u5ea6\u81f3\u91cd\u5ea6AA\u60a3\u8005\u300141\u540dAD\u60a3\u8005\u300121\u540d\u94f6\u5c51\u75c5\u60a3\u8005\u300118\u540dHS\u60a3\u8005\u300125\u540d\u767d\u765c\u98ce\u60a3\u8005\u548c49\u540d\u5e74\u9f84\/\u6027\u522b\u5339\u914d\u7684\u5065\u5eb7\u5bf9\u7167\u3002\u7eb3\u5165\u7684\u60a3\u8005\u5747\u4e3a\u4e2d\u91cd\u5ea6\u75c5\u4f8b\uff0c\u91c7\u7528\u4e25\u683c\u7684\u7eb3\u5165\u548c\u6392\u9664\u6807\u51c6\uff1a\u5e74\u9f84\u226518 \u5c81\uff0c\u4f53\u91cd 40-150kg\uff0c\u75be\u75c5\u75c5\u7a0b\u6216\u4e25\u91cd\u7a0b\u5ea6\u9700\u8fbe\u5230\u7279\u5b9a\u6807\u51c6\uff1b\u4e14\u6392\u9664\u4e86\u8fd1\u671f\u4f7f\u7528\u8fc7\u514d\u75ab\u6291\u5236\u5242\u3001\u751f\u7269\u5236\u5242\u6216\u5c40\u90e8\u514d\u75ab\u8c03\u8282\u5242\u7684\u60a3\u8005\u3002\u5065\u5eb7\u5bf9\u7167\u7ec4\u5728\u5e74\u9f84\u3001\u6027\u522b\u4e0a\u4e0e\u60a3\u8005\u7ec4\u5339\u914d\uff0c\u65e0\u91cd\u5927\u5408\u5e76\u75c7\uff0c\u4e3a\u5bf9\u6bd4\u5206\u6790\u63d0\u4f9b\u4e86\u53ef\u9760\u57fa\u7ebf\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6838\u5fc3\u7814\u7a76\u7ed3\u679c\"><strong>\u6838\u5fc3\u7814\u7a76\u7ed3\u679c<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HS&#8221;\u708e&#8221;\u503c\u6700\u9ad8\uff0c\u767d\u765c\u98ce\u6700&#8221;\u6e29\u548c&#8221;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0d\u540c\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u7cfb\u7edf\u6027\u86cb\u767d\u8d28\u7ec4\u5b66\u5931\u8c03\u7a0b\u5ea6\u5b58\u5728\u663e\u8457\u5dee\u5f02\uff1a<strong>HS \u7684\u5931\u8c03\u6700\u4e3a\u4e25\u91cd<\/strong>\uff0c\u5171\u68c0\u51fa 429 \u79cd\u5dee\u5f02\u8868\u8fbe\u86cb\u767dDEP\uff08358 \u79cd\u4e0a\u8c03\uff0c71 \u79cd\u4e0b\u8c03\uff09\uff1b\u5176\u6b21\u662f AA\uff08496 \u79cd DEP\uff0c326 \u79cd\u4e0a\u8c03\uff0c170 \u79cd\u4e0b\u8c03\uff09\u3001\u94f6\u5c51\u75c5\uff08398\u79cdDEP\uff0c95\u79cd\u4e0a\u8c03\uff0c303\u79cd\u4e0b\u8c03\uff09\u3001AD&nbsp;\uff08221\u79cdDEP\uff0c219\u79cd\u4e0a\u8c03\uff0c2\u79cd\u4e0b\u8c03\uff09\u3002\u767d\u765c\u98ce\u53ea\u670936\u4e2aDEP\uff0c1\u4e2a\u4e0a\u8c03\uff0c35\u4e2a\u4e0b\u8c03\u3002\u503c\u5f97\u6ce8\u610f\u7684\u662f\uff0c<strong>\u4e94\u79cd\u75be\u75c5\u65e0\u5171\u540c\u7684\u4e0a\u8c03\u6216\u4e0b\u8c03\u86cb\u767d\uff0c\u63d0\u793a\u6bcf\u79cd\u75be\u75c5\u5747\u5177\u6709\u72ec\u7279\u7684\u5206\u5b50\u7279\u5f81<\/strong>\uff1b\u800c AA \u4e0e AD\u3001HS \u4e0e\u94f6\u5c51\u75c5\u4e4b\u95f4\u7684\u5dee\u5f02\u86cb\u767d\u91cd\u53e0\u5ea6\u6700\u9ad8\uff0c\u53cd\u6620\u4e86\u75be\u75c5\u4e9a\u578b\u95f4\u7684\u75c5\u7406\u5173\u8054\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"400\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762-1024x400.png\" alt=\"\" class=\"wp-image-1927\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762-1024x400.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762-300x117.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762-768x300.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u540c\u76ae\u80a4\u75c5\u7684\u514d\u75ab\u901a\u8def\u7279\u5f81<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e94\u79cd\u76ae\u80a4\u75c5\u5177\u6709\u5404\u81ea<strong>\u72ec\u7279\u7684\u514d\u75ab\u7279\u5f81\u4e0e\u91cd\u53e0\u7684\u7279\u5f81<\/strong>\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">HS\u5c55\u73b0\u4e86T\u7ec6\u80de\u6fc0\u6d3b\/\u8fc1\u79fb\u8868\u8fbe\u548c\u5148\u5929\u514d\u75ab\u6c34\u5e73\u7684\u4e0a\u8c03\uff0c\u5e76\u89c2\u5bdf\u5230\u4e86CCL7\u4e0e\u8f85\u52a9\u6027T\u7ec6\u80de\u901a\u8def\uff0cTh1\uff0cTh2\uff0cTh17\/22\u7684\u5f3a\u70c8\u4e0a\u8c03\u3002\u7814\u7a76\u8fd8\u53d1\u73b0\u4e86\u4e0e\u4e2d\u6027\u7c92\u7ec6\u80de\u6d3b\u5316\u76f8\u5173\u6807\u5fd7\u7269\u548c\u7c92\u7ec6\u80de\/\u5de8\u566c\u7ec6\u80de\u96c6\u843d\u523a\u6fc0\u56e0\u5b50\u7684\u663e\u8457\u4e0a\u8c03\u3002\u663e\u8457\u4e0b\u8c03\u7684\u6807\u5fd7\u7269\u5219\u4e0e\u8c03\u8282\u7ec6\u80de\u56e0\u5b50\u4fe1\u53f7\u4f20\u5bfc\u548c\u514d\u75ab\u708e\u75c7\u53cd\u5e94\u76f8\u5173\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u94f6\u5c51\u75c5\u4e5f\u5c55\u793a\u51fa\u4e86T\u7ec6\u80de\u6fc0\u6d3b\/\u8fc1\u79fb\/\u6811\u7a81\u72b6\u7ec6\u80de\u6c34\u5e73\u7684\u5347\u9ad8\uff0c\u4e0eHS\u663e\u793a\u51fa\u5171\u540c\u7684<strong>Th1\u548cTh17\/22\u663e\u8457\u6fc0\u6d3b<\/strong>\uff08CXCL10\uff0cIL-19\u7b49\uff09\u3002\u94f6\u5c51\u75c5\u8fd8\u8868\u73b0\u51fa\u4e86\u6fc0\u80bd\u91ca\u653e\u9176\u7684\u4e0a\u8c03\uff0c\u5176\u4e0e\u8868\u76ae\u589e\u751f\u548c\u89d2\u8d28\u5f62\u6210\u7ec6\u80de\u5206\u5316\u6709\u5173\u3002\u663e\u8457\u4e0b\u8c03\u7684\u86cb\u767d\u4e0e\u81ea\u8eab\u514d\u75ab\u708e\u75c7\u8d1f\u8c03\u63a7\u76f8\u5173\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>AA\u548cAD\u7684\u5206\u5b50\u7279\u5f81\u76f8\u8fd1<\/strong>\uff0c\u5747\u5b58\u5728\u4e00\u822c\u708e\u75c7\u6807\u5fd7\u7269\uff08MMP12\uff09\uff0cT\u7ec6\u80de\u6fc0\u6d3b\/\u8fc1\u79fb\/\u6811\u7a81\u72b6\u7ec6\u80de\u6807\u5fd7\u7269\uff0cTh2\u548cTh22\u6807\u5fd7\u7269\u7684\u5171\u540c\u4e0a\u8c03\u3002\u6b64\u5916\uff0cAD\u8fd8\u8868\u73b0\u51fa\u4e86\u90e8\u5206Th1\u548cTh17\u6807\u5fd7\u7269\u7684\u4e0a\u8c03\uff1bAA\u4e5f\u8868\u73b0\u51fa\u4e86\u90e8\u5206\u5173\u952eTh1\u6807\u5fd7\u7269\uff0cTh2\/\u55dc\u9178\u6027\u7c92\u7ec6\u80de\/\u80a5\u5927\u7ec6\u80de\u6807\u5fd7\u7269\u4ee5\u53caTh17\u6807\u5fd7\u7269\u7684\u4e0a\u8c03\u3002AA\u4e2d\u663e\u8457\u4e0b\u8c03\u7684\u6807\u5fd7\u7269\u4e0e\u6c27\u5316\u5e94\u6fc0\u4fdd\u62a4\uff0c\u514d\u75ab\u7ec6\u80de\u8c03\u8282\uff0cT\u7ec6\u80de\u6d3b\u5316\u6216\u7ef4\u6301\u6bdb\u56ca\u7684\u514d\u75ab\u548c\u529f\u80fd\u6709\u5173\u3002\u5c3d\u7ba1AA\u548cAD\u7684Th2\u6fc0\u6d3b\u7a0b\u5ea6\u76f8\u5f53\uff0c\u4f46AA\u66f4\u660e\u663e\u5730\u8868\u73b0\u51fa\u4e86Th1\u548c\u5fc3\u8840\u7ba1\u76f8\u5173\u7684\u5dee\u5f02\uff0c\u8fd9\u4e0e\u76ae\u80a4\/\u5934\u76ae\u90e8\u5206\u7684\u76f8\u5173\u7814\u7a76\u4e00\u81f4\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"849\" height=\"891\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724763.png\" alt=\"\" class=\"wp-image-1928\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724763.png 849w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724763-286x300.png 286w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724763-768x806.png 768w\" sizes=\"auto, (max-width: 849px) 100vw, 849px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u86cb\u767d\u8868\u8fbe\u70ed\u56fe<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>\u76ae\u708e\u4e0e\u5fc3\u8840\u7ba1\u7b49\u75be\u75c5\u98ce\u9669\u7684\u5173\u8054<\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u4eba\u5458\u8bc4\u4f30\u4e86\u8fd9\u4e9b\u75be\u75c5\u4e2d\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u76f8\u5173\u6807\u5fd7\u7269\u7684\u8868\u8fbe\u60c5\u51b5\u3002\u4e0d\u51fa\u610f\u5916\u5730\uff0c<strong>HS\u4f9d\u7136\u8868\u73b0\u51fa\u4e86\u6700\u4e3a\u663e\u8457\u7684\u5931\u8c03\u3002\u6b64\u5916\uff0cAA\uff0cAD\u548c\u94f6\u5c51\u75c5\u4e5f\u5177\u6709\u8f83\u8f7b\u7a0b\u5ea6\u7684\u5931\u8c03<\/strong>\u3002\u767d\u765c\u98ce\u53ea\u663e\u793a\u51fa\u4e0e\u6297\u6c27\u5316\u4fdd\u62a4\u76f8\u5173\u7684\u6807\u5fd7\u7269\u4e0b\u8c03\uff0c\u708e\u75c7\u548c\u5fc3\u8840\u7ba1\u6807\u5fd7\u7269\u7684\u5931\u8c03\u53ef\u5ffd\u7565\u4e0d\u8ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u8fc7GSVA\u5206\u6790\uff0c\u7814\u7a76\u4eba\u5458\u5c06\u6807\u5fd7\u7269\u53d1\u73b0\u6269\u5c55\u5230\u901a\u8def\u5c42\u9762\uff0c\u89c2\u5bdf\u5230\u4e86HS\u5728\u591a\u4e2a\u901a\u8def\u7684\u5bcc\u96c6\u7a0b\u5ea6\u660e\u663e\u9ad8\u4e8e\u5bf9\u7167\u7ec4\u4e0e\u5176\u5b83\u75be\u75c5\uff0c\u5305\u62ecTh1\uff0cTh17\uff0cTh22\/IL22\uff0cJAK\/STAT\uff0c\u5fc3\u8840\u7ba1\u548c\u52a8\u8109\u7ca5\u6837\u786c\u5316\u901a\u8def\u3002AA\u548cAD\u4e5f\u8868\u73b0\u51fa\u7c7b\u4f3c\u7684Th2\u901a\u8def\u4e0a\u8c03\u73b0\u8c61\uff0cAD\u8fd8\u663e\u793a\u51faTh1\uff0cTh17\uff0cTh22\/IL22\uff0cJAK\/STAT\u53ca\u52a8\u8109\u7ca5\u6837\u786c\u5316\u901a\u8def\u7684\u4e0a\u8c03\u3002\u5728\u4e09\u79cd\u76ae\u708e\u4e2d\uff0c<strong>\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u901a\u8def\u5747\u4e0e\u75c5\u60c5\u4e25\u91cd\u7a0b\u5ea6\u663e\u8457\u76f8\u5173<\/strong>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"912\" height=\"889\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724764.png\" alt=\"\" class=\"wp-image-1929\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724764.png 912w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724764-300x292.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724764-768x749.png 768w\" sizes=\"auto, (max-width: 912px) 100vw, 912px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">GSVA Z-score\u7bb1\u7ebf\u56fe<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GO\u5206\u6790\u8868\u660e\uff0cAA\u3001AD\u3001\u94f6\u5c51\u75c5\u548cHS\u4e0a\u8c03\u7684\u5dee\u5f02\u86cb\u767d\u5728<strong>\u591a\u79cd\u901a\u8def\u5bcc\u96c6\uff0c\u5305\u62ec\u708e\u75c7\u53cd\u5e94\uff0c\u7ec6\u80de\u56e0\u5b50\/\u8d8b\u5316\u56e0\u5b50\u4ecb\u5bfc\u7684\u4fe1\u53f7\u901a\u8def\uff0c\u6dcb\u5df4\u7ec6\u80de\u8d8b\u5316\uff0c\u4ee5\u53ca\u7ec6\u80de\u56e0\u5b50\u53cd\u5e94\u6027<\/strong>\u3002AA\u548cAD\u4e5f\u663e\u793a\u51faII\u578b\u5e72\u6270\u7d20\u901a\u8def\u7684\u5bcc\u96c6\u3002\u6b64\u5916\uff0cAA\u7279\u5f02\u6027\u5bcc\u96c6\u4e8e\u8de8\u819c\u53d7\u4f53\u86cb\u767d\u916a\u6c28\u9178\u6fc0\u9176\u4fe1\u53f7\u901a\u8def\uff1bAD\u7279\u5f02\u6027\u5bcc\u96c6\u4e0e\u55dc\u9178\u6027\u7c92\u7ec6\u80de\u8d8b\u5316\u548c\u8fc1\u79fb\u901a\u8def\u3002\u94f6\u5c51\u75c5\u663e\u793a\u51fa\u4e2d\u6027\u7c92\u7ec6\u80de\u8d8b\u5316\/\u8fc1\u79fb\u80fd\u529b\u548c\u6297\u83cc\u4f53\u6db2\u514d\u75ab\u53cd\u5e94\u7684\u5bcc\u96c6\uff0c\u7a81\u663e\u4e86\u4e2d\u6027\u7c92\u7ec6\u80de\u548c\u5148\u5929\u514d\u75ab\u7684\u5173\u952e\u89d2\u8272\u3002HS\u5219\u663e\u793a\u51fa\u7c92\u7ec6\u80de\/\u4e2d\u6027\u7c92\u7ec6\u80de\u8d8b\u5316\uff0c\u591a\u7cd6\u53cd\u5e94\u548c\u7ec6\u83cc\u5206\u5b50\u53cd\u5e94\u7684\u5bcc\u96c6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8840\u6e05\u86cb\u767d\u7ec4\u5931\u8c03\u4e0e\u4e34\u5e8a\u75be\u75c5\u8d1f\u62c5<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u968f\u540e\uff0c\u7814\u7a76\u56e2\u961f<strong>\u9501\u5b9a\u4e86\u4e0e\u6bcf\u79cd\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u4e34\u5e8a\u4e25\u91cd\u7a0b\u5ea6\u76f8\u5173\u7684\u8840\u6e05\u6807\u5fd7\u7269<\/strong>\u3002\u5728AA\u4e2d\uff0cSALT\u8bc4\u5206\u4e0e\u5148\u5929\u514d\u75ab\uff08IL18BP\uff09\u3001T\u7ec6\u80de\u6d3b\u5316\/\u8fc1\u79fb\uff08IL-16\u3001ITGAM\/CD11b\uff09\u3001Th1\uff08CXCL10\u3001CCL2\u3001CCL4\uff09\u3001Th2\uff08IL-4R\u3001IL13RA1\u3001OX40\/TNFRSF4\u3001CCL22\uff09\u3001Th17\/22\uff08IL20RA\u3001IL-32\u3001KYNU\u3001S100A12\uff09\u4ee5\u53ca\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u6807\u5fd7\u7269\uff08PLAUR\u3001HGF\u3001AZU1\uff09\u5747\u5448\u663e\u8457\u6b63\u76f8\u5173\u3002\u7c7b\u4f3c\u5730\uff0c\u5728AD\u60a3\u8005\u4e2d\uff0cSCORAD\u8bc4\u5206\u4e0eTh1\uff08IFNGR1\u3001CXCL9\u3001CXCL10\uff09\u3001Th2\uff08IL-4R\u3001OX40\/TNFRSF4\u3001CCL17\u3001CCL18\u3001CCL22\uff09\u548cTh17\/22\uff08KYNU\uff09\u663e\u8457\u76f8\u5173\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728HS\u60a3\u8005\u4e2d\uff0cIHS4\u8bc4\u5206\u4e0eTh1\uff08IFNG\u3001CXCL9\u3001TNF\uff09\u3001Th2\uff08IL-4R\u3001IL-5\uff09\u3001Th17\uff08IL-17A\u3001IL-17F\u3001PI3\uff09\u4ee5\u53ca\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u6807\u5fd7\u7269\uff08VEGFA\u3001AZU1\u3001PLAUR\uff09\u6b63\u76f8\u5173\u3002\u5728\u94f6\u5c51\u75c5\u60a3\u8005\u4e2d\uff0cPASI\u8bc4\u5206\u4e0e\u5148\u5929\/Th1\u514d\u75ab\u6807\u5fd7\u7269\uff08CXCL8\/IL-8\u3001CCL2\uff09\u3001Th17\uff08IL20RA\uff09\u3001\u5fc3\u8840\u7ba1\u98ce\u9669\u6807\u5fd7\u7269\uff08CCL7\u3001HDGF\uff09\u548cTh2\uff08CCL24\uff09\u663e\u8457\u76f8\u5173\u3002\u8fd9\u4e9b\u53d1\u73b0\u7a81\u51fa\u4e86\u8840\u6e05\u751f\u7269\u6807\u5fd7\u7269\u5931\u8c03\u4e0e\u75be\u75c5\u4e25\u91cd\u5ea6\u7684\u5e7f\u6cdb\u5173\u8054\uff0c\u652f\u6301\u4e86\u7cfb\u7edf\u6027\u514d\u75ab\u6fc0\u6d3b\u5728\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u8fdb\u5c55\u4e2d\u7684\u6838\u5fc3\u4f5c\u7528\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5199\u5728\u6700\u540e\"><strong>\u5199\u5728\u6700\u540e<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be5\u7814\u7a76<strong>\u9996\u6b21\u5927\u89c4\u6a21\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4<\/strong>\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002\u7814\u7a76\u7ed3\u679c\u9a8c\u8bc1\u4e86\u4e94\u79cd\u75be\u75c5\u7684\u7279\u5f02\u6027\u514d\u75ab\u7279\u5f81\uff1aHS\u548c\u94f6\u5c51\u75c5\u5728Th17\u901a\u8def\u4e0a\u91cd\u53e0\uff0c\u4e14HS\u663e\u793a\u51fa\u6700\u5f3a\u7684\u7cfb\u7edf\u6027\u5931\u8c03\uff1bAA\u548cAD\u5171\u4eabTh2\u6fc0\u6d3b\uff0c\u4f46AA\u66f4\u5177Th1\u504f\u659c\u7b49\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be5\u7814\u7a76\u7684\u7ed3\u679c\u4e3a\u9488\u5bf9\u4e0d\u540c\u76ae\u80a4\u75c5\u514d\u75ab\u7279\u5f81\u7684\u7cbe\u51c6\u6cbb\u7597\u7b56\u7565\u63d0\u4f9b\u4e86\u76f4\u63a5\u4f9d\u636e\uff0c\u5e76\u63ed\u793a\u4e86\u5df2\u4e0a\u5e02\u53ca\u5728\u7814\u836f\u7269\u7684\u6f5c\u5728\u5e94\u7528\u4ef7\u503c\u3002\u7814\u7a76\u8868\u660e\uff0cHS\u7684\u75be\u75c5\u4e25\u91cd\u5ea6\u4e0e\u8840\u6e05IL-17A\u6c34\u5e73\u5448\u6b63\u76f8\u5173\uff0c\u8fd9\u4ece\u673a\u5236\u4e0a\u652f\u6301\u4e86\u6297IL-17A\u5355\u514b\u9686\u6297\u4f53<strong>\u53f8\u5e93\u5947\u5c24\u5355\u6297\uff08Secukinumab\uff09<\/strong>&nbsp;\u5728\u8be5\u75c5\u6cbb\u7597\u4e2d\u7684\u7597\u6548\u3002\u6b64\u5916\uff0c\u7814\u7a76\u63d0\u793a\u9488\u5bf9Th17\u901a\u8def\u5176\u4ed6\u9776\u70b9\u7684\u836f\u7269\uff08\u5982<strong>\u6bd4\u7f8e\u5409\u73e0\u5355\u6297\uff08Bimekizumab\uff09\u3001\u5e03\u7f57\u5229\u5c24\u5355\u6297\uff08Brodalumab\uff09<\/strong>&nbsp;\u548c\u6297IL-36R\u836f\u7269<strong>\u53f8\u67cf\u7d22\u5229\u5355\u6297\uff08Spesolimab\uff09<\/strong>\u5728\u76f8\u5173\u75be\u75c5\u4e2d\u53ef\u80fd\u5177\u6709\u5e7f\u9614\u7684\u6cbb\u7597\u6f5c\u529b\u3002\u540c\u65f6\uff0c\u7814\u7a76\u4e5f\u5370\u8bc1\u4e86JAK\u6291\u5236\u5242\uff0c\u5982<strong>\u5df4\u745e\u66ff\u5c3c\uff08Baricitinib\uff09\uff0c<\/strong>&nbsp;\u5728\u6591\u79c3\u4e2d\u7684\u5e94\u7528\u4e0e\u5728\u8c03\u8282\u591a\u7ec6\u80de\u56e0\u5b50\u901a\u8def\u65b9\u9762\u7684\u4ef7\u503c\u3002\u503c\u5f97\u6ce8\u610f\u7684\u662f\uff0c\u7814\u7a76\u53d1\u73b0\u5fc3\u8840\u7ba1\u98ce\u9669\u6807\u5fd7\u7269\uff08\u5982PDGFA\u5728HS\u4e2d\u4e0a\u8c03\uff09\u4e0e\u75be\u75c5\u4e25\u91cd\u5ea6\u5bc6\u5207\u76f8\u5173\uff0c\u8fd9\u5f3a\u8c03\u4e86\u5728\u6cbb\u7597\u76ae\u80a4\u708e\u75c7\u672c\u8eab\u7684\u540c\u65f6\uff0c\u9700\u91c7\u53d6\u7cfb\u7edf\u6027\u6cbb\u7597\u7b56\u7565\u4ee5\u76d1\u6d4b\u548c\u7ba1\u7406\u5176\u4f34\u968f\u7684\u5fc3\u8840\u7ba1\u4ee3\u8c22\u5e76\u53d1\u75c7\uff0c\u4ece\u800c\u5b9e\u73b0\u66f4\u5168\u9762\u7684\u75be\u75c5\u7ba1\u7406\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u53c2\u8003\u6587\u732e\uff1a<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp;Glickman JW, David E, Shokrian N, Hawkins K, Duca ED, Hu BD, Navrazhina K, Carroll B, Mishra A, Estrada YD, Singer G, Krueger JG, Guttman-Yassky E. Large-Scale Blood Proteomic Analysis Across Different Inflammatory Skin Conditions Reveals Extensive Immune Dysregulation With Distinct Biomarker Profiles. Allergy. 2025 Nov 17. doi: 10.1111\/all.70157. Epub ahead of print. PMID: 41246813.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u524d\u5f80\u8d5b\u9ed8\u98deOlink\u4e3b\u9875&gt; \u7814\u7a76\u80cc\u666f 12\u670826\u65e5\uff0c\u5f3a\u751f\u5ba3\u5e03\u5176\u9488\u5bf9\u4e2d\u5ea6\u81f3\u91cd\u5ea6\u7279\u5e94\u6027\u76ae\u708e\u7684\u53cc\u6297\u836f\u7269JNJ-<\/p>\n","protected":false},"author":1852,"featured_media":1927,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[172,173,175],"division":[10],"class_list":["post-1916","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-olink","division-gsd","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31\" \/>\n<meta property=\"og:description\" content=\"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-20T03:42:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-20T03:42:58+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"422\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31\",\"datePublished\":\"2026-05-20T03:42:57+00:00\",\"dateModified\":\"2026-05-20T03:42:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/\"},\"wordCount\":251,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724762.png\",\"keywords\":[\"Olink\",\"olink\u86cb\u767d\u7ec4\u5b66\",\"\u8d5b\u9ed8\u98deOlink\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/\",\"name\":\"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724762.png\",\"datePublished\":\"2026-05-20T03:42:57+00:00\",\"dateModified\":\"2026-05-20T03:42:58+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\\\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724762.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724762.png\",\"width\":1080,\"height\":422},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-dermatitis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/","og_locale":"zh_CN","og_type":"article","og_title":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31","og_description":"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-05-20T03:42:57+00:00","article_modified_time":"2026-05-20T03:42:58+00:00","og_image":[{"width":1080,"height":422,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-dermatitis\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31","datePublished":"2026-05-20T03:42:57+00:00","dateModified":"2026-05-20T03:42:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-dermatitis\/"},"wordCount":251,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png","keywords":["Olink","olink\u86cb\u767d\u7ec4\u5b66","\u8d5b\u9ed8\u98deOlink"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-dermatitis\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/","name":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png","datePublished":"2026-05-20T03:42:57+00:00","dateModified":"2026-05-20T03:42:58+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u8be5\u7814\u7a76\u9996\u6b21\u5927\u89c4\u6a21\u4f7f\u7528Olink Explore\u9ad8\u901a\u91cf\u86cb\u767d\u7ec4\u5b66\u5e73\u53f0\u540c\u65f6\u6bd4\u8f83\u4e86\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6e05\u86cb\u767d\u8d28\u7ec4\uff0c\u63d0\u4f9b\u4e86\u5168\u9762\u7684\u7cfb\u7edf\u6027\u514d\u75ab\u56fe\u8c31\uff0c\u91cd\u70b9\u7814\u7a76\u4e86\u514d\u75ab\u4e0e\u5fc3\u8840\u7ba1\/\u52a8\u8109\u7ca5\u6837\u786c\u5316\u7684\u98ce\u9669\u6807\u5fd7\u7269\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762.png","width":1080,"height":422},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-dermatitis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u4e94\u79cd\u5e38\u89c1\u708e\u75c7\u6027\u76ae\u80a4\u75c5\u7684\u8840\u6db2\u86cb\u767d\u8d28\u7ec4\uff1a\u5171\u4eab\u673a\u5236\u4e0e\u72ec\u7279\u56fe\u8c31"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":172,"label":"Olink"},{"value":173,"label":"olink\u86cb\u767d\u7ec4\u5b66"},{"value":175,"label":"\u8d5b\u9ed8\u98deOlink"}],"division":[{"value":10,"label":"GSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724762-1024x400.png",760,297,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":172,"name":"Olink","slug":"olink","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw","meta":[]},{"term_id":173,"name":"olink\u86cb\u767d\u7ec4\u5b66","slug":"olink%e8%9b%8b%e7%99%bd%e7%bb%84%e5%ad%a6","term_group":0,"term_taxonomy_id":173,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":175,"name":"\u8d5b\u9ed8\u98deOlink","slug":"%e8%b5%9b%e9%bb%98%e9%a3%9eolink","term_group":0,"term_taxonomy_id":175,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1916"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1916\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1927"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1916"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1916"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1916"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}