{"id":1966,"date":"2026-04-30T02:59:45","date_gmt":"2026-04-30T02:59:45","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1966"},"modified":"2026-04-30T02:59:47","modified_gmt":"2026-04-30T02:59:47","slug":"olink-psoriasis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-psoriasis\/","title":{"rendered":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u80cc\u666f\"><strong>\u7814\u7a76\u80cc\u666f<\/strong><\/h2>\n\n\n\n<p><strong>\u94f6\u5c51\u75c5<\/strong>\uff08psoriasis\uff0c\u4fd7\u79f0\u201c\u725b\u76ae\u7663\u201d\uff09\u662f\u4e00\u79cd\u5e38\u89c1\u7684\u6162\u6027\u3001\u590d\u53d1\u6027\uff0c\u514d\u75ab\u4ecb\u5bfc\u7684\u708e\u75c7\u6027\u76ae\u80a4\u75c5\uff0c\u5168\u7403\u60a3\u8005\u8d85\u8fc71.25\u4ebf\u4eba\u3002\u94f6\u5c51\u75c5\u7684\u53d1\u75c5\u673a\u5236\u6d89\u53caT\u7ec6\u80de\u3001\u5148\u5929\u514d\u75ab\u7ec6\u80de\u548c\u89d2\u8d28\u5f62\u6210\u7ec6\u80de\u95f4\u7684\u76f8\u4e92\u4f5c\u7528\u3002\u4f20\u7edf\u7684\u53e3\u670d\u836f\u7269\uff08\u5982\u7532\u6c28\u8776\u5464\u7b49\uff09\u7597\u6548\u6709\u9650\uff0c\u8fd8\u53ef\u80fd\u5f15\u53d1\u4e25\u91cd\u526f\u4f5c\u7528\uff1b\u751f\u7269\u5236\u5242\u9488\u5bf9TNF\u3001IL-23\uff0cIL-17\u7b49\u7ec6\u80de\u56e0\u5b50\u901a\u8def\uff0c\u9700\u8981\u901a\u8fc7\u9759\u8109\u6216\u76ae\u4e0b\u6ce8\u5c04\u7ed9\u836f\uff0c\u7528\u836f\u4f9d\u4ece\u6027\u5dee\u3002\u65b0\u578b\u53e3\u670d\u9776\u5411\u836f\u7269\uff0c\u963f\u666e\u7c73\u53f8\u7279\uff08PDE4\u6291\u5236\u5242\uff09\u548c\u6c18\u53ef\u6765\u6614\u66ff\u5c3c\uff08TYK2\u6291\u5236\u5242\uff09\u4e5f\u5b58\u5728\u7597\u6548\u548c\u5b89\u5168\u6027\u7684\u7f3a\u9677\uff0c<strong>\u4e34\u5e8a\u4e0a\u4ecd\u8feb\u5207\u9700\u8981\u4e00\u6b3e\u7597\u6548\u9ad8\u3001\u5b89\u5168\u6027\u597d\uff0c\u53e3\u670d\u65b9\u4fbf\u7684\u94f6\u5c51\u75c5\u6cbb\u7597\u836f\u7269<\/strong>\u3002<\/p>\n\n\n\n<p>IL-23\/IL-23R\u4fe1\u53f7\u8f74\u7684\u5f02\u5e38\u6fc0\u6d3b\u662f\u94f6\u5c51\u75c5\u53d1\u751f\u53d1\u5c55\u7684\u6838\u5fc3\u673a\u5236\u3002<strong>Icotrokinra\u662f\u5f3a\u751f\u7814\u53d1\u7684\u9996\u6b3e\u53e3\u670d\u9776\u5411IL-23\u53d7\u4f53\u591a\u80bd\u6291\u5236\u5242<\/strong>\uff0c\u5176\u5728\u4e34\u5e8a\u524d\u53ca\u65e9\u671f\u4e34\u5e8a\u8bd5\u9a8c\u4e2d\u5c55\u73b0\u51fa\u7ebf\u6027\u836f\u4ee3\u52a8\u529b\u5b66\u7279\u5f81\uff0c\u5e76\u521d\u6b65\u663e\u73b0\u51fa\u826f\u597d\u7684\u6cbb\u7597\u6f5c\u529b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"395\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724795-1024x395.png\" alt=\"\" class=\"wp-image-1974\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724795-1024x395.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724795-300x116.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724795-768x297.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724795.png 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u4ecb\u7ecd\"><strong>\u7814\u7a76\u4ecb\u7ecd<\/strong><\/h2>\n\n\n\n<p>\u8fd9\u9879\u7814\u7a76\u57fa\u4e8e<strong>FRONTIER-1\u548cFRONTIER-2\u4e34\u5e8a\u8bd5\u9a8c<\/strong>\uff0c\u65e8\u5728\u8bc4\u4f30Icotrokinra\u5728\u4e2d\u91cd\u5ea6\u94f6\u5c51\u75c5\u60a3\u8005\u4e2d\u7684\u7cfb\u7edf\u6027\u548c\u76ae\u80a4\u836f\u6548\u5b66\u53cd\u5e94\u53ca\u5176\u4e0e\u4e34\u5e8a\u7597\u6548\u7684\u5173\u7cfb\u3002FRONTIER-1\u662f\u4e00\u9879\u4e3a\u671f16\u5468\u7684\u968f\u673a\u3001\u53cc\u76f2\u3001\u5b89\u6170\u5242\u5bf9\u7167\u3001\u5242\u91cf\u9012\u589e\u8bd5\u9a8c\uff1bFRONTIER-2\u5219\u662f\u957f\u8fbe52\u5468\u7684\u957f\u671f\u6269\u5c55\u7814\u7a76\u3002<\/p>\n\n\n\n<p><strong>\u7cfb\u7edf\u6027\u53cd\u5e94\uff1a<\/strong>\u901a\u8fc7\u8840\u6e05\u6837\u672c\u6d4b\u91cfIL-23\u901a\u8def\u751f\u7269\u6807\u5fd7\u7269\uff08\u5305\u62ecIL-17A\u3001IL-17F\u3001IL-22\uff0cBD-2\uff09\u548cIL-23\u6c34\u5e73\uff0c\u5e76<strong>\u91c7\u7528Olink Explore\u5e73\u53f0\u8fdb\u884c\u4e86\u5e7f\u8c31\u86cb\u767d\u8d28\u7ec4\u5b66\u5206\u6790<\/strong>\u3002<\/p>\n\n\n\n<p><strong>\u76ae\u80a4\u53cd\u5e94\uff1a<\/strong>\u901a\u8fc7\u76ae\u80a4\u6d3b\u68c0\u6837\u672c\u8fdb\u884c\u8f6c\u5f55\u7ec4\u5b66\u5206\u6790\u94f6\u5c51\u75c5\u76f8\u5173\u57fa\u56e0\u8868\u8fbe\uff1b\u4f7f\u7528<strong>\u80f6\u5e26\u5265\u79bb\uff08tape-strip\uff09\u6837\u672c<\/strong>\u8fdb\u884cOlink\u86cb\u767d\u5b9a\u91cf\u5206\u6790\uff0c\u8bc4\u4f30\u76ae\u635f\uff08lesional\uff09\u4e0e\u975e\u76ae\u635f\uff08non-lesional\uff09\u76ae\u80a4\u5dee\u5f02\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3b\u8981\u7ed3\u679c\"><strong>\u4e3b\u8981\u7ed3\u679c<\/strong><\/h2>\n\n\n\n<p>\u5728FRONTIER-1\u7814\u7a76\u4e2d\uff0c\u63a5\u53d7100mg\u6bcf\u65e5\u4e24\u6b21\u7684\u60a3\u800516\u5468\u65f6\u94f6\u5c51\u75c5\u9762\u79ef\u548c<strong>\u4e25\u91cd\u7a0b\u5ea6\u6307\u6570\u6539\u558475%\u4ee5\u4e0a\u7684\u6bd4\u4f8b\u9ad8\u8fbe79%<\/strong>\uff0c40%\u7684\u60a3\u8005\u5b9e\u73b0\u4e86\u76ae\u80a4\u5b8c\u5168\u6e05\u9664\u3002<\/p>\n\n\n\n<p>\u548c\u5b89\u6170\u5242\u76f8\u6bd4\uff0cIcotrokinra\u53ef\u663e\u8457\u964d\u4f4e\u8840\u6e05\u4e2dIL-17A\u3001IL-17F\uff0cIL-22\u548cBD-2\u7684\u6c34\u5e73\uff0c\u5176\u4e2d100mg\uff0c\u6bcf\u65e5\u4e24\u6b21\uff08BID\uff09\u7684\u5242\u91cf\u6548\u679c\u6700\u7a81\u51fa\u3002\u8be5\u836f\u7269\u5bf9\u4e0a\u8ff0\u751f\u7269\u6807\u5fd7\u7269\u7684\u4e0b\u8c03\u4f5c\u7528\u5728\u7528\u836f\u7b2c4\u5468\u5373\u53ef\u88ab\u68c0\u6d4b\u5230\uff0c\u4e14\u6301\u7eed\u81f3\u6cbb\u7597\u7b2c52\u5468\u3002<strong>\u91c7\u7528Olink Explore HT\u5e73\u53f0\u5bf95,420\u79cd\u8840\u6e05\u86cb\u767d\u8fdb\u884c\u5206\u6790\uff0c\u7ed3\u679c\u663e\u793a\u6cbb\u759752\u5468\u540e\u4ec511\u79cd\u86cb\u767d\u51fa\u73b0\u663e\u8457\u4e0b\u8c03\uff0c\u5176\u4e2d8\u79cd\u6838\u5fc3\u5dee\u5f02\u86cb\u767d\u4e0e\u94f6\u5c51\u75c5\u53d1\u75c5\u673a\u5236\u6216IL-23\u901a\u8def\u6fc0\u6d3b\u76f4\u63a5\u76f8\u5173<\/strong>\uff0cENTHD1\u3001CAMK1G\u548cFKBP1B\u4e3a\u65b0\u53d1\u73b0\u5173\u8054\u86cb\u767d\u3002\u8fd9\u4e00\u7ed3\u679c\u5145\u5206\u8bc1\u5b9e\u4e86Icotrokinra\u4f5c\u7528\u7684\u9ad8\u5ea6\u7279\u5f02\u6027\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1005\" height=\"944\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png\" alt=\"\" class=\"wp-image-1975\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png 1005w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796-300x282.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796-768x721.png 768w\" sizes=\"auto, (max-width: 1005px) 100vw, 1005px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">Icotrokinra\u6cbb\u7597\u60a3\u8005\u4e0e\u5b89\u6170\u5242\u7ec4\u7684\u8840\u6e05\u86cb\u767d\u6807\u5fd7\u7269\u968f\u65f6\u95f4\u53d8\u5316<\/p>\n\n\n\n<p>\u76ae\u80a4\u80f6\u5e26\u5265\u79bb\u68c0\u6d4b\u7ed3\u679c\u663e\u793a\uff0c\u57fa\u7ebf\u72b6\u6001\u4e0b\u94f6\u5c51\u75c5\u60a3\u8005\u76ae\u635f\u4e0e\u975e\u76ae\u635f\u76ae\u80a4\u7684\u86cb\u767d\u8868\u8fbe\u8c31\u5b58\u5728\u663e\u8457\u5dee\u5f02\u3002<strong>\u76ae\u635f\u90e8\u4f4d\u67092,684\u79cd\u86cb\u767d\u8d28\u5448\u73b0\u4e0a\u8c03\u8d8b\u52bf\uff0c\u4e14\u4e0a\u8c03\u86cb\u767d\u4e2d\u6db5\u76d6\u5927\u91cfIL-23\/IL-17\u901a\u8def\u76f8\u5173\u7684\u94f6\u5c51\u75c5\u6838\u5fc3\u86cb\u767d<\/strong>\u3002\u7ecf100mg BID\u6cbb\u759716\u5468\u540e\uff0c\u76ae\u635f\u76ae\u80a4\u4e2d\u5305\u62ecBD-2\u5728\u5185\u7684\u94f6\u5c51\u75c5\u76f8\u5173\u86cb\u767d\u6c34\u5e73\u964d\u81f3\u4e0e\u975e\u76ae\u635f\u76ae\u80a4\u76f8\u5f53\uff0c2,366\u79cd\u86cb\u767d\u8868\u8fbe\u4e0b\u8c03\uff0c13\u79cd\u86cb\u767d\u4e0a\u8c03\u3002\u914d\u5bf9\u5206\u6790\u8fdb\u4e00\u6b65\u8bc1\u5b9e\uff0c<strong>\u6cbb\u759716\u5468\u540e\u76ae\u635f\u76ae\u80a4\u76845,406\u79cd\u86cb\u767d\u8868\u8fbe\u6c34\u5e73\u4e0e\u975e\u76ae\u635f\u76ae\u80a4\u57fa\u7ebf\u6c34\u5e73\u57fa\u672c\u4e00\u81f4\uff0c\u63d0\u793a\u8be5\u836f\u7269\u53ef\u6709\u6548\u9006\u8f6c\u75c5\u53d8\u76ae\u80a4\u7684\u708e\u75c7\u72b6\u6001<\/strong>\u3002\u4e0e\u6b64\u540c\u65f6\uff0c\u76ae\u80a4\u8f6c\u5f55\u7ec4\u5b66\u5206\u6790\u8868\u660e\uff0cIcotrokinra\u80fd\u591f\u663e\u8457\u4e0b\u8c03\u94f6\u5c51\u75c5\u76f8\u5173\u57fa\u56e0\u96c6\u7684\u8868\u8fbe\uff0c\u5176\u4e2d\u5305\u62ecMAD-3\u4e0a\u8c03\u57fa\u56e0\u96c6\u53ca IL-23\/IL-17\u4fe1\u53f7\u901a\u8def\u76f8\u5173\u57fa\u56e0\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1009\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797-1009x1024.png\" alt=\"\" class=\"wp-image-1976\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797-1009x1024.png 1009w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797-296x300.png 296w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797-768x779.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797-80x80.png 80w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724797.png 1080w\" sizes=\"auto, (max-width: 1009px) 100vw, 1009px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">Icotrokinra\u6cbb\u7597\u60a3\u8005\u4e0e\u5b89\u6170\u5242\u7ec4\u7684\u76ae\u80a4\u80f6\u5e26\u86cb\u767d\u6807\u5fd7\u7269\u968f\u65f6\u95f4\u53d8\u5316<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u610f\u4e49\"><strong><strong>\u7814\u7a76\u610f\u4e49<\/strong><\/strong><\/h2>\n\n\n\n<p>Icotrokinra\u662f\u5168\u7403\u9996\u6b3e\u4e14\u552f\u4e00\u4e00\u6b3e\u53e3\u670dIL-23\u53d7\u4f53\u62ee\u6297\u5242\uff0c\u5176\u901a\u8fc7\u72ec\u7279\u7684\u4f5c\u7528\u673a\u5236\uff0c\u7cbe\u51c6\u9776\u5411IL-23\u53d7\u4f53\uff0c\u5b9e\u73b0\u4e86\u5bf9\u708e\u75c7\u7ea7\u8054\u53cd\u5e94\u7684\u6e90\u5934\u963b\u65ad\u30022021\u5e74\uff0c\u5f3a\u751f\u4ee59.8\u4ebf\u7f8e\u5143\u7684\u4ea4\u6613\u603b\u4ef7\u4eceProtagonist\u624b\u4e2d\u62ff\u5230\u4e86\u5305\u62ecIcotrokinra\u5728\u5185\u7684\u4e24\u6b3eIL-23\u5728\u7814\u4ea7\u54c1\u5168\u7403\u6743\u76ca\uff0c\u5f70\u663e\u4e86\u8be5\u836f\u7269\u7684\u5e02\u573a\u4ef7\u503c\u3002\u5176III\u671fICONIC\u7cfb\u5217\u8bd5\u9a8c\u8fdb\u4e00\u6b65\u786e\u8bc1\u4e86\u8be5\u836f\u7269\u7684\u4e34\u5e8a\u7597\u6548\u30022025\u5e747\u6708\uff0c\u5f3a\u751f\u5411FDA\u63d0\u4ea4\u65b0\u836f\u4e0a\u5e02\u7533\u8bf7\uff08NDA\uff09\uff0c\u53ef\u4ee5\u9884\u89c1\uff0c\u8be5\u836f\u7269\u7684\u4e0a\u5e02\uff0c\u6216\u5c06\u6539\u53d8\u73b0\u6709\u7684\u94f6\u5c51\u75c5\u6cbb\u7597\u683c\u5c40\u3002<\/p>\n\n\n\n<p>\u5728\u8fd9\u9879\u4e34\u5e8a\u7814\u7a76\u4e2d\uff0c\u591a\u7ec4\u5b66\u6280\u672f\u7684\u4f7f\u7528\u52a9\u529b\u7814\u7a76\u4eba\u5458\u6e05\u6670\u89c2\u6d4bIcotrokinra\u7528\u836f\u540e\u4f53\u5185\u548c\u76ae\u80a4\u8868\u9762\u7684\u708e\u75c7\u5e94\u7b54\u53d8\u5316\u3002\u5c24\u5176\u662f\u901a\u8fc7\u5206\u6790\u76ae\u80a4\u80f6\u5e26\u5265\u79bb\u4e0b\u6765\u7684\u6837\u672c\u53d1\u73b0\uff0c\u7528\u836f\u540e\u76ae\u635f\u90e8\u4f4d\u708e\u75c7\u6c34\u5e73\u4e0b\u964d\u81f3\u975e\u7834\u635f\u72b6\u6001\uff0c\u5e76\u76f4\u89c2\u9610\u660e\u4e86\u836f\u7269\u7684\u4f5c\u7528\u673a\u5236\u3002\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002<\/p>\n\n\n\n<p><strong>\u53c2\u8003\u8d44\u6599<\/strong><\/p>\n\n\n\n<p>1.&nbsp;Strawn D, Krueger JG, Bissonnette R, et al. Icotrokinra induces early and sustained pharmacodynamic responses in phase IIb study of patients with moderate-to-severe psoriasis. JCI Insight. 2025 Dec 22;10(24):e193563. doi: 10.1172\/jci.insight.193563. PMID: 41424381.<\/p>\n\n\n\n<p>\u4e86\u89e3\u66f4\u591a\u8d5b\u9ed8\u98de<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/brands\/olink-proteomics-protein-biomarker-analysis.html?icid=cn-blog-olink\">Olink\u86cb\u767d\u7ec4\u5b66<\/a>\u4fe1\u606f<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7814\u7a76\u80cc\u666f \u94f6\u5c51\u75c5\uff08psoriasis\uff0c\u4fd7\u79f0\u201c\u725b\u76ae\u7663\u201d\uff09\u662f\u4e00\u79cd\u5e38\u89c1\u7684\u6162\u6027\u3001\u590d\u53d1\u6027\uff0c\u514d\u75ab\u4ecb\u5bfc\u7684\u708e\u75c7\u6027\u76ae\u80a4\u75c5\uff0c\u5168\u7403\u60a3<\/p>\n","protected":false},"author":1852,"featured_media":1975,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[172,173,175,178],"division":[10],"class_list":{"0":"post-1966","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-olink","11":"tag-178","12":"division-gsd","13":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81\" \/>\n<meta property=\"og:description\" content=\"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-30T02:59:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-30T02:59:47+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1005\" \/>\n\t<meta property=\"og:image:height\" content=\"944\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81\",\"datePublished\":\"2026-04-30T02:59:45+00:00\",\"dateModified\":\"2026-04-30T02:59:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/\"},\"wordCount\":112,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724796.png\",\"keywords\":[\"Olink\",\"olink\u86cb\u767d\u7ec4\u5b66\",\"\u8d5b\u9ed8\u98deOlink\",\"\u94f6\u5c51\u75c5\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/\",\"name\":\"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724796.png\",\"datePublished\":\"2026-04-30T02:59:45+00:00\",\"dateModified\":\"2026-04-30T02:59:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724796.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u724796.png\",\"width\":1005,\"height\":944},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-psoriasis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/","og_locale":"zh_CN","og_type":"article","og_title":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81","og_description":"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-04-30T02:59:45+00:00","article_modified_time":"2026-04-30T02:59:47+00:00","og_image":[{"width":1005,"height":944,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-psoriasis\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81","datePublished":"2026-04-30T02:59:45+00:00","dateModified":"2026-04-30T02:59:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-psoriasis\/"},"wordCount":112,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png","keywords":["Olink","olink\u86cb\u767d\u7ec4\u5b66","\u8d5b\u9ed8\u98deOlink","\u94f6\u5c51\u75c5"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-psoriasis\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/","name":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png","datePublished":"2026-04-30T02:59:45+00:00","dateModified":"2026-04-30T02:59:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u5728\u76ae\u80a4\u80f6\u5e26\u7684\u86cb\u767d\u7ec4\u5b66\u68c0\u6d4b\u4e2d\uff0cOlink\u53d1\u6325\u4e86\u5173\u952e\u4f5c\u7528\u3002\u5176\u53ea\u9700\u89811\u20134\u03bcL\u7684\u5fae\u91cf\u6837\u672c\u5c31\u80fd\u7cbe\u51c6\u5206\u6790\u6570\u5343\u91cd\u86cb\u767d\uff0c\u7279\u522b\u9002\u5408\u5904\u7406\u76ae\u80a4\u80f6\u5e26\u7b49\u6837\u672c\u91cf\u6709\u9650\u7684\u57fa\u8d28\u3002\u672a\u6765\uff0c\u7ed3\u5408\u76ae\u80a4\u80f6\u5e26\u53d6\u6837\u548cOlink\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u5c06\u6709\u671b\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5404\u7c7b\u76ae\u80a4\u75be\u75c5\u7814\u7a76\uff0c\u4e3a\u66f4\u591a\u514d\u75ab\u6027\u75be\u75c5\u60a3\u8005\u5e26\u53bb\u5e0c\u671b\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png","width":1005,"height":944},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-psoriasis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"Olink\u5927\u89c4\u6a21\u86cb\u767d\u8d28\u7ec4\u5206\u6790\u63ed\u793a\u5f3a\u751f\u9996\u6b3e\u53e3\u670d\u94f6\u5c51\u75c5\u836f\u7269\u836f\u6548\u5b66\u7279\u5f81"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":172,"label":"Olink"},{"value":173,"label":"olink\u86cb\u767d\u7ec4\u5b66"},{"value":175,"label":"\u8d5b\u9ed8\u98deOlink"},{"value":178,"label":"\u94f6\u5c51\u75c5"}],"division":[{"value":10,"label":"GSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u724796.png",760,714,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":172,"name":"Olink","slug":"olink","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw","meta":[]},{"term_id":173,"name":"olink\u86cb\u767d\u7ec4\u5b66","slug":"olink%e8%9b%8b%e7%99%bd%e7%bb%84%e5%ad%a6","term_group":0,"term_taxonomy_id":173,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":175,"name":"\u8d5b\u9ed8\u98deOlink","slug":"%e8%b5%9b%e9%bb%98%e9%a3%9eolink","term_group":0,"term_taxonomy_id":175,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":178,"name":"\u94f6\u5c51\u75c5","slug":"%e9%93%b6%e5%b1%91%e7%97%85","term_group":0,"term_taxonomy_id":178,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1966"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1966\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1975"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1966"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}