{"id":1984,"date":"2026-05-19T03:15:40","date_gmt":"2026-05-19T03:15:40","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1984"},"modified":"2026-05-19T03:15:42","modified_gmt":"2026-05-19T03:15:42","slug":"olink-ipf","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-ipf\/","title":{"rendered":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76"},"content":{"rendered":"\n<p><strong>\u524d\u5f80<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/brands\/olink-proteomics-protein-biomarker-analysis.html?icid=cn-blog-olink\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d5b\u9ed8\u98deOlink\u4e3b\u9875<\/a>&gt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u80cc\u666f\"><strong><strong>\u7814\u7a76\u80cc\u666f<\/strong><\/strong><\/h2>\n\n\n\n<p><strong><strong>\u4eba\u5de5\u667a\u80fd<\/strong><\/strong>\uff08AI\uff09\u6b63\u5728\u8fc5\u901f\u53d8\u9769\u5236\u836f\u884c\u4e1a\uff0c\u4ece\u9776\u70b9\u53d1\u73b0\u5230\u7cbe\u51c6\u533b\u7597\uff0c\u5168\u65b9\u4f4d\u91cd\u5851\u884c\u4e1a\u683c\u5c40\uff0c\u4e3a<strong>\u52a0\u901f\u836f\u7269\u7814\u53d1<\/strong>\u4e0e\u4e0a\u5e02\u5e26\u6765\u4e86\u524d\u6240\u672a\u6709\u7684\u673a\u9047\u3002\u7136\u800c\uff0c\u5c3d\u7ba1AI\u6280\u672f\u5e94\u7528\u65e5\u76ca\u5e7f\u6cdb\uff0c\u7531AI\u8d4b\u80fd\u7814\u53d1\u5e76\u771f\u6b63\u8fdb\u5165<strong>\u4e34\u5e8a\u8bd5\u9a8c<\/strong>\u9636\u6bb5\u7684\u521b\u65b0\u836f\u7269\u4ecd\u5be5\u5be5\u65e0\u51e0\uff0c\u800c\u5b9e\u73b0<strong>\u4e34\u5e8a\u6982\u5ff5\u9a8c\u8bc1<\/strong>\u7684\u66f4\u662f\u5c11\u4e4b\u53c8\u5c11\u3002\u200d<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u65b0\u6587\u901f\u9012\"><strong>\u65b0\u6587\u901f\u9012<\/strong><\/h2>\n\n\n\n<p><strong><strong>\u82f1\u77fd\u667a\u80fd<\/strong><\/strong>\u7814\u53d1\u56e2\u961f\u53ca\u5176\u5408\u4f5c\u65b9\u4e8e2025\u5e746\u6708\u5728<em>Nature Medicine<\/em>&nbsp;\uff08IF = 58.4\uff09\u6742\u5fd7\u53d1\u8868\u4e86\u4e1a\u5185\u9996\u4e2aAI\u9a71\u52a8\u836f\u7269\u7814\u53d1\u7684\u4e34\u5e8a\u6982\u5ff5\u9a8c\u8bc1\u6210\u679c\uff0c\u5171\u540c\u53d1\u5e03\u4e86<strong>TNIK\u6291\u5236\u5242<\/strong>Rentosertib\uff08ISM001-055\uff09IIa\u671f\u4e34\u5e8a\u8bd5\u9a8c\u7684\u5b89\u5168\u6027\u548c\u6709\u6548\u6027\u6570\u636e\u3002Rentosertib\u662f\u901a\u8fc7\u82f1\u77fd\u667a\u80fd\u751f\u6210\u5f0fAI\u5e73\u53f0Pharma.AI\u8d4b\u80fd\u53d1\u73b0\u8bbe\u8ba1\uff0c\u7528\u4e8e\u6cbb\u7597<strong>\u7279\u53d1\u6027\u80ba\u7ea4\u7ef4\u5316<\/strong>\uff08IPF\uff09\u7684\u5168\u7403\u9996\u521b\u5c0f\u5206\u5b50\u6f5c\u5728\u836f\u7269\u3002\u6b64\u5916\uff0c\u7814\u7a76\u4e2d\u7684<strong>\u63a2\u7d22\u6027\u86cb\u767d\u751f\u7269\u6807\u5fd7\u7269\u5206\u6790<\/strong>\uff0c\u8fdb\u4e00\u6b65\u9a8c\u8bc1\u4e86\u901a\u8fc7\u4eba\u5de5\u667a\u80fd\u65b9\u6cd5\u53d1\u73b0\u7684\u65b0\u9896\u9776\u70b9TNIK\u7684\u751f\u7269\u5b66\u673a\u5236\uff0c\u7814\u7a76\u7ed3\u679c\u652f\u6301Rentosertib\u5177\u6709\u6f5c\u5728\u7684<strong>\u6297\u7ea4\u7ef4\u5316\u53ca\u6297\u708e<\/strong>\u4f5c\u7528\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1025\" height=\"459\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247108.png\" alt=\"\" class=\"wp-image-1993\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247108.png 1025w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247108-300x134.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247108-768x344.png 768w\" sizes=\"auto, (max-width: 1025px) 100vw, 1025px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u89e3\u8bfb\"><strong><strong>\u7814\u7a76\u89e3\u8bfb<\/strong><\/strong><\/h2>\n\n\n\n<p>\u8be5\u7814\u7a76\u4e3b\u8981\u62a5\u9053\u4e86\u4e00\u9879\u540d\u4e3aGENESIS-IPF\u7684IIa\u671f\u7814\u7a76\uff08NCT05938920\uff09\u7ed3\u679c\uff0c\u8fd9\u662f\u9488\u5bf9Rentosertib\u7684\u4e00\u9879\u53cc\u76f2\u3001\u5b89\u6170\u5242\u5bf9\u7167\u4e34\u5e8a\u8bd5\u9a8c\uff0c\u5728\u4e2d\u56fd22\u4e2a\u4e2d\u5fc3\u5171\u5165\u7ec471\u4f8bIPF\u60a3\u8005\uff0c\u53d7\u8bd5\u8005\u88ab\u968f\u673a\u5206\u914d\u63a5\u53d7\u5b89\u6170\u5242\u3001\u6bcf\u65e5\u4e00\u6b2130mg\u3001\u6bcf\u65e5\u4e24\u6b2130mg\u6216\u6bcf\u65e5\u4e00\u6b2160mg\uff0c\u6301\u7eed12\u5468\u7684\u7528\u836f\u89c2\u5bdf\u3002<\/p>\n\n\n\n<p>\u7ed3\u679c\u663e\u793a\uff0cRentosertib\u8fbe\u5230\u4e3b\u8981\u7814\u7a76\u7ec8\u70b9\uff0c\u5373\u5177\u6709\u53ef\u63a7\u7684\u5b89\u5168\u6027\u548c\u8010\u53d7\u6027\u3002\u4ece\u6570\u636e\u6765\u770b\uff0c\u5404\u6cbb\u7597\u7ec4\u4e2d\u4e0e\u6cbb\u7597\u76f8\u5173\u7684\u4e0d\u826f\u4e8b\u4ef6\uff08TEAEs\uff09\u53d1\u751f\u7387\u76f8\u4f3c\uff0c\u5927\u591a\u6570\u4e0d\u826f\u4e8b\u4ef6\uff08AEs\uff09\u4e3a\u8f7b\u5ea6\u6216\u4e2d\u5ea6\uff0c\u4e25\u91cd\u4e0d\u826f\u4e8b\u4ef6\uff08SAEs\uff09\u53d1\u751f\u7387\u7f55\u89c1\uff0c\u4e14\u6240\u6709\u4e0d\u826f\u4e8b\u4ef6\u5728\u505c\u836f\u540e\u5747\u53ef\u6062\u590d\u3002\u5728\u6b21\u8981\u7597\u6548\u7ec8\u70b9\u65b9\u9762\uff0cRentosertib\u540c\u6837\u53d6\u5f97\u4e86\u4ee4\u4eba\u9f13\u821e\u7684\u7ed3\u679c\u3002\u4e3a\u671f12\u5468\u7684\u8bd5\u9a8c\u4e2d\uff0c\u4ee5\u7528\u529b\u80ba\u6d3b\u91cf\uff08FVC\uff09\u8fd9\u4e00\u8bc4\u4ef7IPF\u60a3\u8005\u80ba\u529f\u80fd\u7684\u91d1\u6807\u51c6\u6765\u770b\uff0c\u5728\u63a5\u53d7\u6cbb\u7597\u7684\u60a3\u8005\u4e2d\u89c2\u5bdf\u5230\u5242\u91cf\u4f9d\u8d56\u6027\u7684\u80ba\u529f\u80fd\u6539\u5584\u3002\u5728\u6bcf\u65e5\u4e00\u6b2160mg\u7684\u6700\u9ad8\u7528\u836f\u5242\u91cf\u7ec4\u4e2d\uff0c\u60a3\u8005\u7684FVC\u4e0e\u57fa\u7ebf\u6c34\u5e73\u76f8\u6bd4\uff0c\u5e73\u5747\u63d0\u9ad898.4\u6beb\u5347\uff0c\u800c\u5b89\u6170\u5242\u7ec4\u60a3\u8005\u7684FVC\u4e0e\u57fa\u7ebf\u6c34\u5e73\u76f8\u6bd4\uff0c\u5e73\u5747\u4e0b\u964d20.3\u6beb\u5347\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"926\" height=\"376\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png\" alt=\"\" class=\"wp-image-1994\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png 926w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109-300x122.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109-768x312.png 768w\" sizes=\"auto, (max-width: 926px) 100vw, 926px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u4e0e\u57fa\u7ebf\u6570\u636e\u76f8\u6bd4\uff0cRentosertib\u6cbb\u759712\u5468\u540eFVC\u7684\u53d8\u5316<\/p>\n\n\n\n<p>\u6b64\u5916\uff0c\u8be5\u7814\u7a76\u4f7f\u7528<strong>Olink\u86cb\u767d\u7ec4\u5b66<\/strong>\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027<strong>\u751f\u7269\u6807\u5fd7\u7269<\/strong>\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002\u4f7f\u7528<strong>Olink Explore 3072<\/strong>\u8bd5\u5242\u76d2\u5bf9\u6240\u6709\u6cbb\u7597\u7ec4\u60a3\u8005\u57fa\u7ebf\u671f\u3001\u7b2c2\u5468\u3001\u7b2c4\u5468\u548c\u7b2c12\u5468\u7684\u8840\u6e05\u6837\u672c\u8fdb\u884c\u5206\u6790\uff0c\u5171\u9274\u5b9a\u51fa<strong>2,841<\/strong>\u79cd\u86cb\u767d\u8d28\u3002\u901a\u8fc7\u7ebf\u6027\u56de\u5f52\u6a21\u578b\u8bc4\u4f30Rentosertib\u6cbb\u7597\u5bf9\u86cb\u767d\u8868\u8fbe\u7684\u65f6\u6548\u6027\u5f71\u54cd\uff0c\u53d1\u73b0\u6cbb\u7597\u65f6\u957f\u663e\u8457\u6539\u53d8\u86cb\u767d\u8d28\u8868\u8fbe\u6a21\u5f0f\uff1a<strong>\u7b2c2\u30014\u300112\u5468\u5206\u522b\u670920\u300182\u548c192\u79cd\u86cb\u767d\u8d28\u53d1\u751f\u663e\u8457\u53d8\u5316<\/strong>\u3002<\/p>\n\n\n\n<p>\u91c7\u7528\u7edf\u8ba1\u5206\u6790\u548c\u5e7f\u4e49\u7ebf\u6027\u6a21\u578b\u9274\u5b9a\u51fa30 mg QD\u300130 mg BID\u548c60 mg QD\u5242\u91cf\u7ec4\u60a3\u8005\u8840\u6e05\u4e2d\u663e\u8457\u5f71\u54cd\u7684\u86cb\u767d\uff08P\u503c&lt;0.05\uff09\uff08\u4e0b\u56fea, b\uff09\uff0c\u5176\u4e2d\u5206\u522b\u5b58\u57281\u30018\u548c22\u79cd\u9ad8\u7f6e\u4fe1\u5ea6\u5dee\u5f02\u4e30\u5ea6\u86cb\u767d\uff08Padj\u503c&lt;0.05\uff09\u3002\u53e6\u5916\u7528\u914d\u5bf9T\u68c0\u9a8c\u5206\u6790\u57fa\u7ebf\u81f3\u7b2c<strong>12\u5468<\/strong>\u7684\u5dee\u5f02\u86cb\u767d\u53d1\u73b0\uff0c\u66f4\u9ad8\u5242\u91cf\u5bfc\u81f4\u663e\u8457\u6539\u53d8\u86cb\u767d\u6570\u91cf\u5927\u5e45\u589e\u52a0\uff1a30 mg QD\u7ec40\u4e2a\uff0c30 mg BID\u7ec4<strong>39\u4e2a<\/strong>\uff0c60 mg QD\u7ec4<strong>115\u4e2a<\/strong>\u3002\u7ed3\u679c\u8868\u660e\uff0cRentosertib\u7684<strong>\u6cbb\u7597\u65f6\u957f<\/strong>\u548c<strong>\u5242\u91cf<\/strong>\u5747\u4e0e<strong>\u8840\u6e05\u86cb\u767d\u7279\u5f81\u56fe\u8c31<\/strong>\u53d8\u5316\u76f8\u5173\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1017\" height=\"495\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247110.png\" alt=\"\" class=\"wp-image-1995\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247110.png 1017w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247110-300x146.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247110-768x374.png 768w\" sizes=\"auto, (max-width: 1017px) 100vw, 1017px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u63a5\u53d7Rentosertib\u6cbb\u7597\uff08a. 30mg BID ;b. 60mg QD\uff09\u540e\u7684\u8840\u6e05\u5dee\u5f02\u86cb\u767d<\/p>\n\n\n\n<p>\u572830 mg BID\u548c60 mg QD\u6cbb\u7597\u7ec4\u4e2d\uff0c<strong>\u4e0b\u8c03\u86cb\u767d<\/strong>\u5305\u62ec\u5df2\u77e5\u7ea4\u7ef4\u5316\u76f8\u5173\u86cb\u767d\uff1aMMP10\u3001PTPRZ1\u3001COL1A1\u3001FAP\u3001FN1\u3001ROBO2\u3001ASPN\u548cLTBP2(\u4e0b\u56fec, d)\u3002\u901a\u8fc7\u5206\u6790\u5dee\u5f02\u4e30\u5ea6\u86cb\u767d\u4e0e\u7528\u529b\u80ba\u6d3b\u91cf\uff08FVC\uff09\u53d8\u5316\u7684\u5173\u8054\uff0c\u53d1\u73b0<strong>ASPN<\/strong>\u3001<strong>PTPRZ1<\/strong>\u3001<strong>MMP10<\/strong>\u548c<strong>CHAD<\/strong>\u4e0d\u4ec5\u4e0eFVC\u53d8\u5316\u5448\u663e\u8457\u8d1f\u76f8\u5173\uff08P&lt;0.05\uff09\uff0c\u4e14\u5728\u6cbb\u7597\u7b2c12\u5468\u65f6\u663e\u8457\u4e0b\u8c03\uff0c\u63d0\u793a\u5176\u53ef\u4f5c\u4e3a<strong>\u6cbb\u7597\u53cd\u5e94<\/strong>\u7684\u6f5c\u5728\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8def\u5bcc\u96c6\u5206\u6790\u663e\u793a\uff0c\u7ec6\u80de\u5916\u57fa\u8d28\u7ec4\u7ec7\u662f\u4e24\u7ec4\u6cbb\u7597\u4e2d\u6700\u663e\u8457\u4e0b\u8c03\u7684\u5bcc\u96c6\u901a\u8def\uff0c\u8868\u660e\u8fc7\u5ea6\u7ec6\u80de\u5916\u57fa\u8d28\u751f\u6210\u53d7\u5230\u6291\u5236\uff08\u4e0b\u56fee\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"643\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111-1024x643.png\" alt=\"\" class=\"wp-image-1996\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111-1024x643.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111-300x189.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111-768x483.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111-320x200.png 320w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247111.png 1063w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u8fdb\u4e00\u6b65\u7814\u7a76\u53d1\u73b0\uff0c\u65e2\u5f80\u62a5\u9053\u4e0eIPF\u60a3\u8005\u80ba\u529f\u80fd\u548c\u65e0\u79fb\u690d\u751f\u5b58\u671f\u76f8\u5173\u7684\u86cb\u767d\uff08\u5982ADAMTSL2\u3001COL6A3\u3001CCN3\u3001COL24A1\u3001KRT19\u548cLTBP2\uff09\u5728<strong>\u7b2c12\u5468\u7684\u4e30\u5ea6\u53d8\u5316<\/strong>\u4e0e<strong>FVC<\/strong>\u6539\u53d8\u76f8\u5173\u3002\u708e\u75c7\u76f8\u5173\u901a\u8def\u3001\u5176\u4ed6\u514d\u75ab\u76f8\u5173\u86cb\u767d\uff08\u5982IL-10\u3001CD5\uff09\u53ca\u7ec6\u80de\u5916\u57fa\u8d28\u76f8\u5173\u86cb\u767d\uff08\u5982COL6A3\uff09\u7684\u8868\u8fbe\u6c34\u5e73\uff0c\u5747\u4e0e\u6cbb\u7597\u65f6\u957f\u548cFVC\u53d8\u5316\u663e\u8457\u5173\u8054\uff0c\u8fdb\u4e00\u6b65\u8868\u660eTNIK\u5728\u591a\u79cd\u8870\u8001\u76f8\u5173\u5931\u8c03\u901a\u8def\u4e2d\u5177\u6709\u5e7f\u6cdb\u4f5c\u7528\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u603b\u7ed3\"><strong>\u7814\u7a76\u603b\u7ed3<\/strong><\/h2>\n\n\n\n<p>Rentosertib IIa\u671f\u4e34\u5e8a\u7814\u7a76\u7ed3\u679c\u663e\u793a\uff0c\u63a5\u53d760 mg\u6bcf\u65e5\u4e00\u6b21Rentosertib\u6cbb\u7597\u7684\u60a3\u8005\uff0c\u7528\u529b\u80ba\u6d3b\u91cf\uff08FVC\uff09\u5e73\u5747\u6539\u5584\u5e45\u5ea6\u6700\u5927\u3002\u7814\u7a76\u4e2d\u7684\u63a2\u7d22\u6027\u751f\u7269\u6807\u5fd7\u7269\u5206\u6790\u8fdb\u4e00\u6b65\u9a8c\u8bc1\u4e86\u901a\u8fc7\u4eba\u5de5\u667a\u80fd\u65b9\u6cd5\u53d1\u73b0\u7684\u65b0\u9896\u9776\u70b9TNIK\u7684\u751f\u7269\u5b66\u673a\u5236\uff0c\u7814\u7a76\u7ed3\u679c\u652f\u6301Rentosertib\u5177\u6709\u6f5c\u5728\u7684\u6297\u7ea4\u7ef4\u5316\u53ca\u6297\u708e\u4f5c\u7528\u3002\u8fd9\u4e9b\u53d1\u73b0\u4e0e\u4e34\u5e8a\u524d\u7814\u7a76\u7ed3\u679c\u4e3a\u5f00\u5c55\u4e0b\u4e00\u6b65\u4e34\u5e8a\u9a8c\u8bc1\u7684\u5242\u91cf\u9009\u62e9\u548c\u751f\u7269\u6807\u5fd7\u7269\u8bc6\u522b\u63d0\u4f9b\u4e86\u5b9d\u8d35\u7684\u6307\u5bfc\u3002<\/p>\n\n\n\n<p><strong>\u53c2\u8003\u8d44\u6599\uff1a<\/strong><br>1.&nbsp;Xu Z, Ren F, Wang P, Cao J, Tan C, Ma D, Zhao L, Dai J, Ding Y, Fang H, Li H, Liu H, Luo F, Meng Y, Pan P, Xiang P, Xiao Z, Rao S, Satler C, Liu S, Lv Y, Zhao H, Chen S, Cui H, Korzinkin M, Gennert D, Zhavoronkov A. A generative AI-discovered TNIK inhibitor for idiopathic pulmonary fibrosis: a randomized phase 2a trial. Nat Med. 2025 Jun 3.&nbsp;<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u524d\u5f80\u8d5b\u9ed8\u98deOlink\u4e3b\u9875&gt; \u7814\u7a76\u80cc\u666f \u4eba\u5de5\u667a\u80fd\uff08AI\uff09\u6b63\u5728\u8fc5\u901f\u53d8\u9769\u5236\u836f\u884c\u4e1a\uff0c\u4ece\u9776\u70b9\u53d1\u73b0\u5230\u7cbe\u51c6\u533b\u7597\uff0c\u5168\u65b9\u4f4d<\/p>\n","protected":false},"author":1852,"featured_media":1994,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[172,173,175],"division":[10],"class_list":{"0":"post-1984","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-olink","11":"division-gsd","12":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76\" \/>\n<meta property=\"og:description\" content=\"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-19T03:15:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-19T03:15:42+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png\" \/>\n\t<meta property=\"og:image:width\" content=\"926\" \/>\n\t<meta property=\"og:image:height\" content=\"376\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76\",\"datePublished\":\"2026-05-19T03:15:40+00:00\",\"dateModified\":\"2026-05-19T03:15:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/\"},\"wordCount\":200,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247109.png\",\"keywords\":[\"Olink\",\"olink\u86cb\u767d\u7ec4\u5b66\",\"\u8d5b\u9ed8\u98deOlink\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/\",\"name\":\"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247109.png\",\"datePublished\":\"2026-05-19T03:15:40+00:00\",\"dateModified\":\"2026-05-19T03:15:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247109.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247109.png\",\"width\":926,\"height\":376},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-ipf\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/","og_locale":"zh_CN","og_type":"article","og_title":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76","og_description":"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-05-19T03:15:40+00:00","article_modified_time":"2026-05-19T03:15:42+00:00","og_image":[{"width":926,"height":376,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-ipf\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76","datePublished":"2026-05-19T03:15:40+00:00","dateModified":"2026-05-19T03:15:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-ipf\/"},"wordCount":200,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png","keywords":["Olink","olink\u86cb\u767d\u7ec4\u5b66","\u8d5b\u9ed8\u98deOlink"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-ipf\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/","name":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png","datePublished":"2026-05-19T03:15:40+00:00","dateModified":"2026-05-19T03:15:42+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u8be5\u7814\u7a76\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u6280\u672f\u63a2\u7d22Rentosertib\u4f5c\u7528\u673a\u5236\u4ee5\u53ca\u4e0e\u7597\u6548\u76f8\u5173\u7684\u6f5c\u5728\u9884\u540e\u6216\u9884\u6d4b\u6027\u751f\u7269\u6807\u5fd7\u7269\u3002\u901a\u8fc7\u5bf9\u60a3\u8005\u8840\u6e05\u6837\u672c\u8fdb\u884c\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u65e8\u5728\u63a2\u7a76Rentosertib\u7684\u4f5c\u7528\u673a\u5236\u3001\u6307\u5bfc\u751f\u7269\u6807\u5fd7\u7269\u7684\u5f00\u53d1\uff0c\u5e76\u9a8c\u8bc1\u6291\u5236TNIK\u53ef\u80fd\u9776\u5411\u751f\u7269\u8870\u8001\u7684\u5047\u8bf4\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png","width":926,"height":376},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-ipf\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u4e2d\u56fd\u5236\u836f\u521b\u65b0\uff5cOlink\u52a9\u529b\u82f1\u77fd\u667a\u80fdAI\u9a71\u52a8\u7684\u6297IPF\u5019\u9009\u836f\u7269IIa\u671f\u4e34\u5e8a\u7814\u7a76"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":172,"label":"Olink"},{"value":173,"label":"olink\u86cb\u767d\u7ec4\u5b66"},{"value":175,"label":"\u8d5b\u9ed8\u98deOlink"}],"division":[{"value":10,"label":"GSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247109.png",760,309,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":172,"name":"Olink","slug":"olink","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw","meta":[]},{"term_id":173,"name":"olink\u86cb\u767d\u7ec4\u5b66","slug":"olink%e8%9b%8b%e7%99%bd%e7%bb%84%e5%ad%a6","term_group":0,"term_taxonomy_id":173,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":175,"name":"\u8d5b\u9ed8\u98deOlink","slug":"%e8%b5%9b%e9%bb%98%e9%a3%9eolink","term_group":0,"term_taxonomy_id":175,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1984","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1984"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1984\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1994"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1984"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1984"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1984"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}