{"id":1992,"date":"2026-05-13T02:20:46","date_gmt":"2026-05-13T02:20:46","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=1992"},"modified":"2026-05-13T02:20:47","modified_gmt":"2026-05-13T02:20:47","slug":"olink-explore-ckb","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-explore-ckb\/","title":{"rendered":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u524d\u5f80<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/brands\/olink-proteomics-protein-biomarker-analysis.html?icid=cn-blog-olink\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d5b\u9ed8\u98deOlink\u4e3b\u9875<\/a>&gt;<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u80cc\u666f\"><strong>\u7814\u7a76\u80cc\u666f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6c14\u5019\u53d8\u5316<\/strong>\u88ab\u8ba4\u4e3a\u662f\u4eba\u7c7b\u9762\u4e34\u7684\u201c\u6700\u5927\u5065\u5eb7\u5a01\u80c1\u201d\uff0c\u5176\u673a\u5236\u662f\u901a\u8fc7\u63d0\u9ad8\u73af\u5883\u6e29\u5ea6\u548c\u6781\u7aef\u5929\u6c14\u4e8b\u4ef6\uff0c\u4ece\u800c\u6539\u53d8\u4eba\u7fa4\u5bf9<strong>\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6<\/strong>\uff08\u5373\u708e\u70ed\u548c\u5bd2\u51b7\uff09\u7684\u66b4\u9732\uff0c\u8fd9\u5728\u5168\u7403\u8303\u56f4\u5185\u5177\u6709\u76f8\u5173\u6027\u3002\u4e0e\u5de5\u4e1a\u5316\u524d\u6c34\u5e73\u76f8\u6bd4\uff0c\u8fc7\u53bb\u5341\u5e74\u5168\u7403\u5730\u8868\u6e29\u5ea6\u4e0a\u5347\u4e86<strong>1.1\u00b0C<\/strong>\u3002\u591a\u56fd\u751f\u6001\u7814\u7a76\u786e\u5b9a\u4e86\u4e0e\u6700\u5c0f\u65e5\u6b7b\u4ea1\u7387\u76f8\u5173\u7684\u4e0d\u540c\u9002\u5b9c\u6e29\u5ea6\uff0c\u8fd9\u4e9b\u6e29\u5ea6\u56e0\u4e0d\u540c\u9002\u5e94\u80fd\u529b\u7684\u4eba\u7fa4\u800c\u5f02\uff0c\u4e00\u822c\u8303\u56f4\u5728<strong>18\u221225\u00b0C<\/strong>\u4e4b\u95f4\u30022019\u5e74\uff0c\u6839\u636e\u77ed\u671f\u5065\u5eb7\u5f71\u54cd\u7684\u751f\u6001\u7814\u7a76\u7ed3\u679c\uff0c\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4f30\u8ba1\u5bfc\u81f4\u8d85\u8fc7<strong>500\u4e07\u4eba\u6b7b\u4ea1<\/strong>\u3002\u5f53\u5317\u98ce\u547c\u5578\u6216\u70c8\u65e5\u708e\u708e\u65f6\uff0c\u6211\u4eec\u7684\u8eab\u4f53\u4f1a\u8fc5\u901f\u505a\u51fa\u6700\u76f4\u89c2\u7684\u53cd\u5e94\uff0c\u6bd4\u5982\u6253\u51b7\u98a4\u6216\u6d41\u6c57\u3002\u9664\u4e86\u8fd9\u4e9b\u76f4\u89c2\u7684\u4f53\u611f\u53d8\u5316\uff0c\u73af\u5883\u6e29\u5ea6\u8fd8\u4e0e<strong>\u4eba\u4f53\u751f\u7406\u673a\u80fd<\/strong>\u548c<strong>\u5065\u5eb7\u72b6\u51b5<\/strong>\u5bc6\u5207\u76f8\u5173\u3002\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u5f80\u5f80\u662f\u4e16\u754c\u8303\u56f4\u5185<strong>\u4e3b\u8981\u75be\u75c5\u7684\u8bf1\u53d1\u56e0\u7d20<\/strong>\u4e4b\u4e00\uff0c\u7136\u800c\uff0c\u5176\u80cc\u540e\u7684<strong>\u75c5\u7406\u5b66\u673a\u5236<\/strong>\u5374\u9c9c\u6709\u7814\u7a76\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u65b0\u6587\u901f\u9012\"><strong>\u65b0\u6587\u901f\u9012<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e2d\u56fd\u6162\u6027\u75c5\u524d\u77bb\u6027\u7814\u7a76\u9879\u76ee<\/strong>\uff08China Kadoorie Biobank, CKB\uff09\u4e8c\u671f\u82f1\u65b9\u8d1f\u8d23\u4eba<strong>\u9648\u94ee\u9e23\u6559\u6388\uff08<\/strong>\u56fd\u9645\u8457\u540d\u6d41\u884c\u75c5\u5b66\u5bb6\u3001\u6b27\u6d32\u79d1\u5b66\u9662\u9662\u58eb\u3001\u725b\u6d25\u5927\u5b66\u7ebd\u83f2\u5c14\u5fb7\u4eba\u53e3\u5065\u5eb7\u7cfb\u9996\u4efb\u7406\u67e5\u5fb7\u00b7\u4f69\u6258\u6d41\u884c\u75c5\u5b66\u8bb2\u5e2d\u6559\u6388\u3001\u73b0\u4efb\u725b\u6d25\u5927\u5b66\u6559\u6388\uff09\u56e2\u961f\u8fd1\u671f<strong>\u73af\u5883\u79d1\u5b66<\/strong>\u9886\u57df\u56fd\u9645\u671f\u520a<em>Environmental Science &amp; Technology&nbsp;<\/em>\uff08IF =10.8\uff09\u4e0a\u53d1\u8868\u4e86\u6700\u65b0\u7814\u7a76\u6210\u679c\uff1a\u7814\u7a76\u57fa\u4e8e<strong>CKB\u9879\u76ee<\/strong>\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528<strong>Olink Explore 3072<\/strong>\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684<strong>\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316<\/strong>\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86<strong>\u73af\u5883\u6e29\u5ea6<\/strong>\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684<strong>\u201c\u5065\u5eb7\u5730\u56fe\u201d<\/strong>\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"467\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112-1024x467.png\" alt=\"\" class=\"wp-image-1999\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112-1024x467.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112-300x137.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112-768x351.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9648\u94ee\u9e23\u6559\u6388<\/strong>\u5c06\u4e8e6\u67085\u65e5\u5468\u56db\u4e0b\u5348\u53d7\u9080\u53c2\u52a0&nbsp;<a href=\"https:\/\/mp.weixin.qq.com\/s?__biz=Mzg4ODU0NTQ5Nw==&amp;mid=2247491068&amp;idx=1&amp;sn=7f08d19c22914ce4bb3514f2c0c83638&amp;scene=21#wechat_redirect\" target=\"_blank\" rel=\"noreferrer noopener\">Olink&nbsp;\u4e2d\u56fd\u7b2c\u4e09\u5c4a\u86cb\u767d\u7ec4\u5b66\u5cf0\u4f1a<\/a>\uff0c\u5206\u4eab\u9898\u76ee\u4e3a&#8221;<strong>\u5f00\u62d3\u4ee5\u751f\u7269\u5927\u6570\u636e\u9a71\u52a8\u7684\u7cbe\u51c6\u533b\u5b66<\/strong>&#8220;\u7684\u5927\u4f1a\u4e3b\u9898\u62a5\u544a\u3002\u8bda\u631a\u9080\u8bf7\u60a8\u9884\u7ea6\u53c2\u4f1a\uff0c\u4e0e\u56fd\u5185\u5916\u884c\u4e1a\u4e13\u5bb6\u5171\u805a2025&nbsp;Olink\u4e2d\u56fd\u7b2c\u4e09\u5c4a\u86cb\u767d\u7ec4\u5b66\u5cf0\u4f1a\uff01<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"299\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-299x1024.png\" alt=\"\" class=\"wp-image-2000\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-299x1024.png 299w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-88x300.png 88w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-768x2630.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-449x1536.png 449w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-598x2048.png 598w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247113-scaled.png 748w\" sizes=\"auto, (max-width: 299px) 100vw, 299px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7814\u7a76\u8bbe\u8ba1\"><strong>\u7814\u7a76\u8bbe\u8ba1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be5\u7814\u7a76\u57fa\u4e8e<strong>CKB\u6536\u96c6<\/strong>\u7684\u6837\u672c\uff0c\u8986\u76d6\u5168\u56fd10\u4e2a\u5730\u533a\uff0c\u7eb3\u5165\u4e861,951\u4f8b<strong>\u7a81\u53d1\u7f3a\u8840\u6027\u5fc3\u810f\u75c5<\/strong>\uff08IHD\uff09\u6837\u672c\u4ee5\u53ca2,026\u4f8b\u57fa\u7ebf\u65e0\u5fc3\u8840\u7ba1\u75c5\u53f2\u7684\u968f\u673a\u4e9a\u961f\u5217\u4e2a\u4f53\u3002\u6c14\u8c61\u5b66\u6570\u636e\u4e3b\u8981\u6765\u6e90\u4e8e\u6743\u5a01\u5929\u6c14\u9884\u62a5\u4e2d\u5fc3\uff08European Centre for Medium Range Weather Forecasts\uff0cECMWF\uff09\u7684\u65e5\u5747\u7a7a\u6c14\u6e29\u5ea6\uff08\u2103\uff09\u548c\u76f8\u5bf9\u6e7f\u5ea6\uff08RH, %\uff09\u3002\u901a\u8fc7<strong>Olink Explore 3072 panel<\/strong>\uff0c\u7814\u7a76\u8005\u6d4b\u91cf\u4e86\u53c2\u4e0e\u8005\u57fa\u7ebf\u8840\u6d46\u6837\u672c\u4e2d<strong>2,923\u4e2a<\/strong>\u86cb\u767d\u8868\u8fbe\u6c34\u5e73\u3002\u5728\u5254\u9664\u7f3a\u5c11\u6e29\u5ea6\u6570\u636e\u7684\u4e2a\u4f53\u540e\uff0c\u5171\u67093,925\u540d\u4e2a\u4f53\u7684\u6837\u672c\u88ab\u7eb3\u5165\u6700\u7ec8\u5206\u6790\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"275\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247114.png\" alt=\"\" class=\"wp-image-2001\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247114.png 500w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247114-300x165.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u8005\u8fd0\u7528<strong>\u5206\u5e03\u5f0f\u6ede\u540e\u975e\u7ebf\u6027\u6a21\u578b<\/strong>\uff08DLNM\uff09\uff0c\u540c\u65f6\u5206\u6790\u4e86\u6e29\u5ea6\u77ed\u671f\u6ce2\u52a8\uff080-7\u5929\uff09\u4e0e\u86cb\u767d\u8868\u8fbe\u7684\u5ef6\u8fdf\u54cd\u5e94\uff0c\u8fd9\u79cd\u52a8\u6001\u8ffd\u8e2a\u4e3a\u63ed\u793a\u6e29\u5ea6\u7684\u590d\u6742\u4f5c\u7528\u673a\u5236\u63d0\u4f9b\u4e86\u65b0\u7684\u89c6\u89d2\u3002\u4e3a\u4e86\u8bc4\u4f30\u4e0e\u6e29\u5ea6\u53d8\u5316\u76f8\u5173\u7684<strong>\u5dee\u5f02\u8868\u8fbe\u86cb\u767d<\/strong>\uff08DEPs\uff09\uff0c\u7814\u7a76\u8005\u8bc6\u522b\u4e86\u4e0e<strong>\u57fa\u7ebf\u6536\u7f29\u538b<\/strong>\uff08SBP\uff09\u548c<strong>\u524d\u77bb\u6027IHD\u4e8b\u4ef6<\/strong>\u76f8\u5173\u7684\u86cb\u767d\uff0c\u8fd9\u4e24\u4e2a\u4e8b\u4ef6\u5747\u88ab\u5e7f\u6cdb\u8ba4\u4e3a\u4e0e\u6e29\u5ea6\u76f8\u5173\u3002\u968f\u540e\uff0c\u7814\u7a76\u8005\u91c7\u7528\u5e7f\u4e49\u7ebf\u6027\u56de\u5f52\u548cCox\u56de\u5f52\u8fdb\u884c\u5206\u6790\uff0c\u5c06\u9274\u5b9a\u51fa\u7684DEPs\u4e0e\u5148\u524d\u7814\u7a76\u8fdb\u884c\u5206\u5e03\u5bf9\u6bd4\uff0c\u5e76\u5229\u7528KEGG\u5bcc\u96c6\u5206\u6790\u548cReactome\u6570\u636e\u5e93\u6765\u8bc6\u522b\u5176\u751f\u7269\u5b66\u529f\u80fd\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8be6\u7ec6\u89e3\u8bfb\"><strong>\u8be6\u7ec6\u89e3\u8bfb<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>949\u79cd\u86cb\u767d\u8868\u8fbe\u53d7\u5230\u6e29\u5ea6\u5f71\u54cd<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u6240\u6709\u6ede\u540e\u6a21\u578b\u4e2d\uff0c\u53d1\u73b0<strong>949\u79cd\u86cb\u767d<\/strong>\u4e0e\u73af\u5883\u6e29\u5ea6\u663e\u8457\u76f8\u5173\u3002\u5176\u4e2d\uff0c387\u79cd\uff08216\u79cd\u4e0b\u8c03\uff0c171\u79cd\u4e0a\u8c03\uff09\u4e0e\u5bd2\u51b7\u76f8\u5173\uff1b<strong>770\u79cd<\/strong>\uff08656\u79cd\u4e0b\u8c03\uff0c114\u79cd\u4e0a\u8c03\uff09\u4e0e<strong>\u708e\u70ed<\/strong>\u76f8\u5173\u3002\u5f53\u6e29\u5ea6\u9ad8\u4e8e\u4e2d\u4f4d\u53c2\u8003\u6e29\u5ea6\uff0817.7\u00b0C\uff09\u65f6\uff0c\u76f8\u5173\u6027\u57fa\u672c\u5448\u7ebf\u6027\uff1b\u800c\u4f4e\u4e8e\u53c2\u8003\u6e29\u5ea6\u65f6\u5219\u5448\u975e\u7ebf\u6027\uff0c\u5e76\u4ee55\u00b0C\u8870\u51cf\uff0c\u8fd9\u4e5f\u53cd\u6620\u4e86\u4f9b\u6696\u6240\u5e26\u6765\u7684\u8c03\u8282\u6027\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6709\u8da3\u7684\u662f\uff0c<strong>208\u79cd\u86cb\u767d<\/strong>\u5bf9\u5bd2\u51b7\u548c\u708e\u70ed\u5177\u6709<strong>\u4ea4\u53c9\u5f71\u54cd<\/strong>\u3002\u5728\u6700\u5177\u7edf\u8ba1\u5b66\u5dee\u5f02\u7684\u663e\u8457\u86cb\u767d\u4e2d\uff0cSNED1\u3001PARP1\u3001STX7\u3001SPINK6\u548cSLURP1\u5728\u5bd2\u51b7\u65f6\u4e0b\u8c03\uff0c\u540c\u5728\u708e\u70ed\u65f6\u4e0a\u8c03\uff1bLRP1\u3001CD69\u3001SNAP23\u3001CCL2\u548cSRC\u5728\u5bd2\u51b7\u65f6\u4e0a\u8c03\uff0c\u5728\u708e\u70ed\u65f6\u4e0b\u8c03\uff1b\u800cHSPB6\u3001MB\u3001CD40LG\u3001CRTAC1\u548cNCS1\u5219\u5448\u73b0\u4e0e\u6e29\u5ea6\u7684U\u578b\u5173\u7cfb\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"752\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247115-752x1024.png\" alt=\"\" class=\"wp-image-2002\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247115-752x1024.png 752w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247115-220x300.png 220w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247115-768x1046.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247115.png 944w\" sizes=\"auto, (max-width: 752px) 100vw, 752px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>\u6e29\u5ea6\u5f71\u54cdDEPs\u4e0eSBP\u548cIHD\u7684\u5173\u7cfb<\/strong><\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728949\u79cd\u5dee\u5f02\u8868\u8fbe\u86cb\u767d\uff08DEPs\uff09\u4e2d\uff0c<strong>773\u79cd<\/strong>\uff08\u5360\u6bd481%\uff09\u4e0e<strong>\u57fa\u7ebf\u6536\u7f29\u538b<\/strong>\uff08SBP\uff09\u6216<strong>\u7a81\u53d1\u7f3a\u8840\u6027\u5fc3\u810f\u75c5<\/strong>\uff08IHD\uff09\u5b58\u5728\u5173\u8054\uff0c\u5176\u4e2d<strong>153\u79cd<\/strong>\u4e3a\u4e24\u8005\u5171\u540c\u76f8\u5173\u7684\u5dee\u5f02\u86cb\u767d\u3002\u5728773\u79cd\u76f8\u5173\u86cb\u767d\u4e2d\uff0c\u6709<strong>577\u79cd\u56e0\u708e\u70ed\u800c\u4e0b\u8c03<\/strong>\uff0c\u5e76\u4e0eSBP\u548cIHD\u5448\u6b63\u76f8\u5173\u3002\u5728<strong>153\u79cd\u76f8\u4e92\u91cd\u53e0<\/strong>\u7684\u86cb\u767d\u4e2d\uff0c\u5927\u90e8\u5206\u5728KEGG\u901a\u8def\u4e2d\u5177\u6709\u663e\u8457\u6027\uff0c\u6d89\u53ca\u75c5\u6bd2\u86cb\u767d\u4e0e\u7ec6\u80de\u56e0\u5b50\u3001\u7ec6\u80de\u56e0\u5b50\u53d7\u4f53\u76f8\u4e92\u4f5c\u7528\u901a\u8def\u3001COVID-19\u3001\u8d8b\u5316\u56e0\u5b50\u4fe1\u53f7\u3001\u51dd\u8840\u7ea7\u8054\u53cd\u5e94\u548c\u7ec6\u80de\u56e0\u5b50\u53d7\u4f53\u76f8\u4e92\u4f5c\u7528\u7b49\uff1b\u5728Reactome\u901a\u8def\u4e2d\uff0c\u4e3b\u8981\u5bcc\u96c6\u4e8e\u6b62\u8840\u3001\u7ec6\u80de\u5916\u57fa\u8d28\u7ec4\u7ec7\u548c\u4fe1\u53f7\u8f6c\u5bfc\u7b49\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9153\u79cd\u91cd\u53e0\u86cb\u767d\u8fdb\u884c<strong>\u5bcc\u96c6\u5206\u6790<\/strong>\u53d1\u73b0\uff0c\u5176\u4e3b\u8981\u5bcc\u96c6\u901a\u8def\u5305\u62ec<strong>\u8840\u5c0f\u677f\u6fc0\u6d3b<\/strong>\u3001\u4fe1\u53f7\u4f20\u5bfc\u548c\u805a\u96c6\u3001\u8131\u9897\u7c92\u3001\u6b62\u8840\u548c\u8d8b\u5316\u56e0\u5b50\u7b49\u3002\u603b\u4f53\u800c\u8a00\uff0c\u8840\u5c0f\u677f\u6fc0\u6d3b\u86cb\u767d\u5728\u5bd2\u51b7\u65f6\u4e0a\u8c03\uff0c\u708e\u70ed\u65f6\u4e0b\u8c03\uff1b\u767d\u4ecb\u7d20\u4fe1\u53f7\u86cb\u767d\u5728\u708e\u70ed\u65f6\u4e0a\u8c03\uff1b\u800c\u4fe1\u53f7\u8f6c\u5bfc\u3001\u8840\u5c0f\u677f\u6fc0\u6d3b\u3001\u4fe1\u53f7\u4f20\u5bfc\u548c\u805a\u96c6\u3001\u8102\u8d28\u4ee3\u8c22\u548c\u52a8\u8109\u7ca5\u6837\u786c\u5316\u4ee5\u53ca<strong>\u514d\u75ab\u7cfb\u7edf<\/strong>\u76f8\u5173\u86cb\u767d\u5219\u5728\u708e\u70ed\u65f6\u4e0b\u8c03\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"867\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247116-867x1024.png\" alt=\"\" class=\"wp-image-2003\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247116-867x1024.png 867w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247116-254x300.png 254w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247116-768x907.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247116.png 1080w\" sizes=\"auto, (max-width: 867px) 100vw, 867px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">DEPs\u4e0e\u6e29\u5ea6\uff0cSBP\u548cIHD\u7684\u76f8\u5173\u6027\uff0ctop10 KEGG\u548cReactome\u901a\u8def<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f9b\u6696\u5f71\u54cd\u4e0e\u75be\u75c5\u76f8\u5173\u901a\u8def\u5206\u6790<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u8868\u660e\uff0c<strong>\u4f7f\u7528\u4f9b\u6696\u8bbe\u5907\u53ef\u5c06\u5bd2\u51b7\u5bf9\u86cb\u767d\u5f71\u54cd\u51cf\u5c1150%<\/strong>\u3002\u5728CKB\u4eba\u7fa4\u4e2d\uff0c\u8840\u538b\uff08BP\uff09\u4e5f\u5448\u73b0\u51fa\u7c7b\u4f3c\u7684\u66b4\u9732-\u53cd\u5e94\u6a21\u5f0f\uff0c\u4e14\u4e0e\u6e29\u5ea6\u5177\u6709\u7ebf\u6027\u76f8\u5173\u6027\uff08\u5f53\u6e29\u5ea6\u9ad8\u4e8e10\u00b0C\u65f6\uff0c\u6e29\u5ea6\u6bcf\u5347\u9ad81\u00b0C\uff0c\u6536\u7f29\u538b\uff08SBP\uff09\u4e0b\u964d0.6mmHg\uff09\uff0c\u8fd9\u8868\u660e\u4f7f\u7528\u4f9b\u6696\u8bbe\u5907\u7684\u4eba\u7fa4\u5bf9\u5bd2\u51b7\u7684\u9002\u5e94\u80fd\u529b\u66f4\u5f3a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u53d1\u73b0\uff0c\u8d85\u8fc780%\u7684\u4e0e\u6e29\u5ea6\u76f8\u5173\u7684\u5dee\u5f02\u8868\u8fbe\u86cb\u767d\uff08DEPs\uff09\u4e0e<strong>SBP<\/strong>\u6216<strong>IHD<\/strong>\u6709\u5173\u3002\u8fd9\u4e9b\u91cd\u53e0\u7684DEPs\u5305\u62ec\u8d8b\u5316\u56e0\u5b50\uff08\u5982CCL2\u3001CXCL5\u3001CXCL3\u548cPPBP\uff09\u3001\u9176\uff08\u5982MMP1\u548cMMP7\uff09\u3001\u767d\u4ecb\u7d20\uff08\u5982IL22\u548cIL15\uff09\u7b49\u708e\u75c7\u514d\u75ab\u76f8\u5173\u86cb\u767d\uff0c\u5b83\u4eec\u4e0e<strong>\u5fc3\u8840\u7ba1\u75be\u75c5<\/strong>\u7b49\u591a\u79cd\u75be\u75c5\u7684\u53d1\u75c5\u673a\u5236\u5bc6\u5207\u76f8\u5173\u3002\u9664\u4e86\u4e0eSBP\u548c\u8840\u8102\u6709\u5173\u5916\uff0c\u7814\u7a76\u8fd8\u53d1\u73b0\u4e00\u4e9b\u6e29\u5ea6\u76f8\u5173\u86cb\u767d\u4e5f\u4e0e\u5176\u4ed6\u591a\u79cd\u75be\u75c5\u7684\u53d1\u75c5\u673a\u5236\u6709\u5173\u3002\u4f8b\u5982\uff0c<strong>SNED1<\/strong>\u662f\u4e00\u79cd\u7ec6\u80de\u5916\u57fa\u8d28\u86cb\u767d\uff0c\u5728\u5bd2\u51b7\u65f6\u4e0b\u8c03\uff0c\u5728\u708e\u70ed\u65f6\u4e0a\u8c03\uff0c\u5b83\u88ab\u53d1\u73b0\u662f<strong>\u4e73\u817a\u764c\u8f6c\u79fb<\/strong>\u7684\u4fc3\u8fdb\u56e0\u5b50\uff0c\u5e76\u5728\u4e00\u9879\u897f\u73ed\u7259\u7684\u76f8\u5173\u7814\u7a76\u4e2d\u5f97\u5230\u4e86\u8bc1\u5b9e\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5199\u5728\u6700\u540e\"><strong>\u5199\u5728\u6700\u540e<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u9996\u6b21\u9488\u5bf9<strong>\u4e1c\u4e9a\u4eba\u7fa4<\/strong>\uff0c\u8bc4\u4f30\u4e86\u73af\u5883\u6e29\u5ea6\u5bf9\u4eba\u4f53\u86cb\u767d\u7ec4\u7684\u6025\u6027\u5f71\u54cd\uff0c\u53d1\u73b0\u4e86<strong>949\u79cd<\/strong>\u4e0e\u73af\u5883\u6e29\u5ea6\u663e\u8457\u76f8\u5173\u7684\u86cb\u767d\u8d28\uff0c\u5176\u4e2d\u8d85\u8fc780%\u4e0e\u6536\u7f29\u538b\u548c\u7a81\u53d1\u7f3a\u8840\u6027\u5fc3\u810f\u75c5\u6709\u5173\uff0c\u5e76\u5728\u708e\u75c7\u3001\u514d\u75ab\u548c\u8840\u5c0f\u677f\u805a\u96c6\u7b49\u75c5\u7406\u5b66\u901a\u8def\u4e2d\u663e\u8457\u5bcc\u96c6\u3002\u8fd9\u4e9b\u5dee\u5f02\u8868\u8fbe\u86cb\u767d\u4e0e<strong>\u591a\u79cd\u75be\u75c5\u901a\u8def<\/strong>\u76f8\u5173\u8054\uff0c\u5e76\u901a\u8fc7\u5176\u4ed6\u7814\u7a76\u7684\u6570\u636e\u5f97\u5230\u4e86\u8fdb\u4e00\u6b65\u9a8c\u8bc1\uff0c\u8fd9\u4e0d\u4ec5\u51f8\u663e\u4e86Olink\u5e73\u53f0\u5728\u68c0\u6d4b\u5177\u6709<strong>\u5b9e\u9645\u751f\u7269\u5b66\u529f\u80fd<\/strong>\u7684\u86cb\u767d\u65b9\u9762\u7684\u53ef\u9760\u6027\uff0c\u4e5f\u4e3a\u5f00\u53d1\u73af\u5883\u6e29\u5ea6\u76f8\u5173\u75be\u75c5\u7684\u9884\u8b66\u7cfb\u7edf\u5960\u5b9a\u4e86\u575a\u5b9e\u57fa\u7840\u3002\u672a\u6765\uff0c\u57fa\u4e8e\u86cb\u767d\u7f51\u7edc\u7684\u201c<strong>\u6e29\u5ea6\u5065\u5eb7\u6307\u6570<\/strong>\u201d\u6709\u671b\u6210\u4e3a\u516c\u5171\u536b\u751f\u653f\u7b56\u5236\u5b9a\u7684\u91cd\u8981\u79d1\u5b66\u4f9d\u636e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u63a8\u8350\u9605\u8bfb<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/mp.weixin.qq.com\/s?__biz=Mzg4ODU0NTQ5Nw==&amp;mid=2247490140&amp;idx=1&amp;sn=4fe2da3253865f175d4d1738fb606af5&amp;scene=21#wechat_redirect\" target=\"_blank\" rel=\"noreferrer noopener\">CKB\/UKB\u65b0\u6210\u679c\uff5cOlink\u86cb\u767d\u7ec4\u5b66\u52a9\u529b2\u578b\u7cd6\u5c3f\u75c5\u9884\u6d4b\u548c\u65b0\u836f\u9776\u53d1\u73b0<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/mp.weixin.qq.com\/s?__biz=Mzg4ODU0NTQ5Nw==&amp;mid=2247490338&amp;idx=1&amp;sn=4dca263b40a8076afe68f5a39ec87f38&amp;scene=21#wechat_redirect\" target=\"_blank\" rel=\"noreferrer noopener\">Nat Med\u91cd\u78c5\u7eed\u7bc7\uff5cUKB\/CKB\/Finngen\u4e09\u56fd\u961f\u5217\u4f7f\u7528Olink\u5e73\u53f0\u63a2\u7d22\u86cb\u767d\u7ec4\u5b66\u5e74\u9f84\u65f6\u949f<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/mp.weixin.qq.com\/s?__biz=Mzg4ODU0NTQ5Nw==&amp;mid=2247489498&amp;idx=1&amp;sn=e0d84220bde7ec2337b02c0226e74a48&amp;scene=21#wechat_redirect\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e2d\u56fd\u6162\u6027\u75c5\u524d\u77bb\u6027\u7814\u7a76\uff5cOlink\u86cb\u767d\u8d28\u7ec4\u52a9\u529b\u53d1\u73b0\u7f3a\u8840\u6027\u5fc3\u810f\u75c5\u65b0\u836f\u9776<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/mp.weixin.qq.com\/s?__biz=Mzg4ODU0NTQ5Nw==&amp;mid=2247490319&amp;idx=1&amp;sn=670192167b159973bd72d678568bd4c0&amp;scene=21#wechat_redirect\" target=\"_blank\" rel=\"noreferrer noopener\">UKB\u91cd\u78c5\u65b0\u4f5c\uff5c\u82f1\u56fd\u5251\u6865\u5927\u5b66\u56e2\u961f\u4f7f\u7528Olink\u86cb\u767d\u7ec4\u5b66\u5f00\u521b\u4e0a\u767e\u79cd\u75be\u75c5\u9884\u6d4b\u65b0\u7eaa\u5143<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u53c2\u8003\u8d44\u6599<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp;https:\/\/baike.baidu.com\/item\/%E9%99%88%E9%93%AE%E9%B8%A3\/624089612. Guo YT. et. al., China Kadoorie Biobank Study Group. Acute Impact of Nonoptimal Ambient Temperatures on Plasma Levels of 3000 Proteins in Chinese Adults. Environ Sci Technol. 2025 Mar 18;59(10):4868-4882.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u524d\u5f80\u8d5b\u9ed8\u98deOlink\u4e3b\u9875&gt; \u7814\u7a76\u80cc\u666f \u6c14\u5019\u53d8\u5316\u88ab\u8ba4\u4e3a\u662f\u4eba\u7c7b\u9762\u4e34\u7684\u201c\u6700\u5927\u5065\u5eb7\u5a01\u80c1\u201d\uff0c\u5176\u673a\u5236\u662f\u901a\u8fc7\u63d0\u9ad8\u73af\u5883\u6e29<\/p>\n","protected":false},"author":1852,"featured_media":1999,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[51],"tags":[172,173,175],"division":[10],"class_list":["post-1992","post","type-post","status-publish","format-standard","has-post-thumbnail","category-51","tag-olink","division-gsd","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31\" \/>\n<meta property=\"og:description\" content=\"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-13T02:20:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-13T02:20:47+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"493\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31\",\"datePublished\":\"2026-05-13T02:20:46+00:00\",\"dateModified\":\"2026-05-13T02:20:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/\"},\"wordCount\":159,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247112.png\",\"keywords\":[\"Olink\",\"olink\u86cb\u767d\u7ec4\u5b66\",\"\u8d5b\u9ed8\u98deOlink\"],\"articleSection\":[\"\u6750\u6599\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/\",\"name\":\"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247112.png\",\"datePublished\":\"2026-05-13T02:20:46+00:00\",\"dateModified\":\"2026-05-13T02:20:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247112.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/04\\\/\u56fe\u7247112.png\",\"width\":1080,\"height\":493},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/olink-explore-ckb\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/","og_locale":"zh_CN","og_type":"article","og_title":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31","og_description":"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-05-13T02:20:46+00:00","article_modified_time":"2026-05-13T02:20:47+00:00","og_image":[{"width":1080,"height":493,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-explore-ckb\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31","datePublished":"2026-05-13T02:20:46+00:00","dateModified":"2026-05-13T02:20:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-explore-ckb\/"},"wordCount":159,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png","keywords":["Olink","olink\u86cb\u767d\u7ec4\u5b66","\u8d5b\u9ed8\u98deOlink"],"articleSection":["\u6750\u6599\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/olink-explore-ckb\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/","name":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png","datePublished":"2026-05-13T02:20:46+00:00","dateModified":"2026-05-13T02:20:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u7814\u7a76\u57fa\u4e8eCKB\u9879\u76ee\u4e2d\u6765\u81ea10\u4e2a\u5730\u533a\u76843,926\u540d\u6210\u5e74\u4eba\uff0c\u4f7f\u7528Olink Explore 3072\u5e73\u53f0\u5bf9\u53c2\u4e0e\u8005\u7684\u8840\u6d46\u6837\u672c\u8fdb\u884c\u5927\u89c4\u6a21\u86cb\u767d\u7ec4\u5b66\u5206\u6790\uff0c\u63ed\u793a\u4e86\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\uff08\u5982\u5bd2\u51b7\u6216\u708e\u70ed\uff09\u5f15\u53d1\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u8d28\u7ec4\u53d8\u5316\uff0c\u8fd9\u4e9b\u53d8\u5316\u53ef\u80fd\u4e0e\u8840\u538b\u5347\u9ad8\u548c\u5fc3\u8111\u8840\u7ba1\u7b49\u75be\u75c5\u5bc6\u5207\u76f8\u5173\u3002\u8fd9\u9879\u57fa\u4e8eCKB\u961f\u5217\u5386\u65f6\u5341\u591a\u5e74\u7684\u5927\u89c4\u6a21\u7814\u7a76\uff0c\u9996\u6b21\u4e3a\u4e2d\u56fd\u4eba\u7fa4\u7ed8\u5236\u4e86\u73af\u5883\u6e29\u5ea6\u4e0e\u4eba\u4f53\u86cb\u767d\u7ec4\u5173\u7cfb\u7684\u201c\u5065\u5eb7\u5730\u56fe\u201d\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112.png","width":1080,"height":493},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/olink-explore-ckb\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"Olink Explore\u52a9\u529b\u7ed8\u5236\u975e\u9002\u5b9c\u73af\u5883\u6e29\u5ea6\u4e0b\u7684\u4eba\u4f53\u8840\u6d46\u86cb\u767d\u7ec4\u5065\u5eb7\u56fe\u8c31"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":51,"label":"\u6750\u6599\u79d1\u5b66"}],"post_tag":[{"value":172,"label":"Olink"},{"value":173,"label":"olink\u86cb\u767d\u7ec4\u5b66"},{"value":175,"label":"\u8d5b\u9ed8\u98deOlink"}],"division":[{"value":10,"label":"GSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/04\/\u56fe\u7247112-1024x467.png",760,347,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":51,"name":"\u6750\u6599\u79d1\u5b66","slug":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":51,"taxonomy":"category","description":"","parent":0,"count":30,"filter":"raw","meta":[],"cat_ID":51,"category_count":30,"category_description":"","cat_name":"\u6750\u6599\u79d1\u5b66","category_nicename":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":172,"name":"Olink","slug":"olink","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw","meta":[]},{"term_id":173,"name":"olink\u86cb\u767d\u7ec4\u5b66","slug":"olink%e8%9b%8b%e7%99%bd%e7%bb%84%e5%ad%a6","term_group":0,"term_taxonomy_id":173,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":175,"name":"\u8d5b\u9ed8\u98deOlink","slug":"%e8%b5%9b%e9%bb%98%e9%a3%9eolink","term_group":0,"term_taxonomy_id":175,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=1992"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/1992\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/1999"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=1992"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=1992"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=1992"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=1992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}