{"id":2211,"date":"2026-06-17T02:36:46","date_gmt":"2026-06-17T02:36:46","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=2211"},"modified":"2026-06-17T02:36:48","modified_gmt":"2026-06-17T02:36:48","slug":"toxic-gases-in-food-and-the-threat-of-ethylene-oxide","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/","title":{"rendered":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/communities-social\/socialhub\/blog-subscribe.html?icid=cn-blog-subscribe\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-1024x176.jpg\" alt=\"\u8ba2\u9605subscribe\" class=\"wp-image-2271\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/779-\u00d7-134-3-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5f15\u8a00\"><strong>\u5f15\u8a00<\/strong><\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/13442-og-1-300x200.jpg\" alt=\"\" class=\"wp-image-12042\" \/><\/figure>\n<\/div>\n\n\n<p>\u73af\u6c27\u4e59\u70f7\uff08Ethylene Oxide\uff0cEtO\uff09\u81ea1991\u5e74\u4ee5\u6765\u5728\u6b27\u76df\u88ab\u7981\u6b62\u4f7f\u7528\u3002\u50cf\u5fb7\u56fd\u8fd9\u6837\u7684\u56fd\u5bb6\u65e9\u57281981\u5e74\u5c31\u5df2\u7ecf\u7981\u6b62\u4e86\u5b83\u3002\u4f46\u5728\u5370\u5ea6\u3001\u7f8e\u56fd\u548c\u52a0\u62ff\u5927\u7b49\u56fd\u5bb6\uff0c\u5b83\u4ecd\u88ab\u7528\u4e8e\u6740\u706d\u98df\u54c1\u4e2d\u7684\u7ec6\u83cc\u548c\u771f\u83cc\uff0c\u4f8b\u5982\u829d\u9ebb\u7c7d\u3001\u4e00\u822c\u6cb9\u7c7d\u3001\u575a\u679c\u548c\u74dc\u5c14\u80f6\u7b49\u3002\u81ea2021\u5e747\u6708\u8d77\uff0c\u6b27\u76df\u89c4\u5b9a\u6240\u6709\u542b\u6709\u9ad8\u4e8e0.1\u6beb\u514b\/\u5343\u514b\u5b9a\u91cf\u9650\uff08LOQ\uff09\u7684\u73af\u6c27\u4e59\u70f7\u4ea7\u54c1\u90fd\u5fc5\u987b\u64a4\u51fa\u5e02\u573a\u3002\u8fd9\u4e00\u51b3\u5b9a\u7531<a href=\"https:\/\/ec.europa.eu\/food\/system\/files\/2021-07\/rasff_ethylene-oxide-incident_e410_crisis-coord_sum.pdf\"><u>\u6b27\u76df\u59d4\u5458\u4f1a\u4f5c\u51fa<\/u><\/a>\u3002<\/p>\n\n\n\n<p>\u8fd9\u4e0d\u4ec5\u9002\u7528\u4e8e\u539f\u6750\u6599\uff0c\u4e5f\u9002\u7528\u4e8e\u6210\u54c1\u98df\u54c1\u3002\u74dc\u5c14\u80f6\uff08E410\uff09\u53ef\u89c1\u4e8e\u51b0\u6dc7\u6dcb\u3001\u679c\u9171\u3001\u8089\u7c7b\u548c\u70d8\u7119\u4ea7\u54c1\u3002\u5728\u6cd5\u56fd\uff0c\u5df2\u6709\u6570\u767e\u79cd\u51b0\u6dc7\u6dcb\u4e0d\u5f97\u4e0d<a href=\"https:\/\/www.foodwatch.org\/de\/aktuelle-nachrichten\/2021\/zusatzstoff-mit-krebserregendem-ethylenoxid-verunreinigt\/\"><u>\u64a4\u51fa\u5e02\u573a<\/u><\/a>\u3002<\/p>\n\n\n\n<p><a href=\"https:\/\/www.bfr.bund.de\/cm\/343\/gesundheitliche-bewertung-von-ethylenoxid-rueckstaenden-in-sesamsamen.pdf\"><u>BfR<\/u><\/a>(\u5fb7\u56fd\u8054\u90a6\u98ce\u9669\u7ba1\u7406\u5c40)\u8868\u793a\uff0c\u73af\u6c27\u4e59\u70f7\u53ef\u80fd\u4e0e\u764c\u75c7\u6709\u5173\uff0c\u5e76\u5177\u6709\u81f4\u7a81\u53d8\u4f5c\u7528\u3002\u4ee5\u829d\u9ebb\u4e3a\u4f8b\uff0c34\u7c92\u53d7\u6c61\u67d3\u7684\u829d\u9ebb\u7c7d\u4e2d\u6240\u542b\u7684\u73af\u6c27\u4e59\u70f7\u8db3\u4ee5\u6784\u6210\u4e25\u91cd\u5065\u5eb7\u98ce\u9669\u3002<\/p>\n\n\n\n<p>\u6b27\u76df\u89c4\u5b9a\u4e86\u68c0\u51fa\u9650\uff08LOD\uff09\u4e3a0.05&nbsp;mg\/kg\uff0c\u8be5\u6570\u503c\u5305\u542b\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u53ca\u5176\u4ee3\u8c22\u4ea7\u72692-\u6c2f\u4e59\u9187\uff082-Chloroethanol\uff09\u7684\u603b\u548c\uff0c\u5e76\u4ee5\u73af\u6c27\u4e59\u70f7\u8ba1\u3002<\/p>\n\n\n\n<p>\u90a3\u4e48\uff0c\u4e3a\u4ec0\u4e48\u8fd9\u7a81\u7136\u53d8\u5f97\u5982\u6b64\u91cd\u8981\uff1f2020\u5e74\u7f51\u4e0a\u6709\u591a\u4efd\u58f0\u660e\/\u51fa\u7248\u7269\u58f0\u79f0\u73af\u6c27\u4e59\u70f7\u53ef\u4ee5\u7528\u4e8e\u706d\u6740\u65b0\u51a0\u75c5\u6bd2\u3002\u8fd9\u53ef\u80fd<a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/fighting-covid-19-the-double-face-of-ethylene-oxide-eo\/\"><u>\u5bf9\u4e8e\u533b\u7597\u5668\u68b0\u6765\u8bf4<\/u><\/a>\u662f\u6b63\u786e\u7684\uff0c\u7136\u800c\u98df\u54c1\u5219\u662f\u53e6\u4e00\u56de\u4e8b\u3002<\/p>\n\n\n\n<p>\u7ed3\u679c\u662f\u7a81\u7136\u95f4\uff0c\u66f4\u591a\u98df\u54c1\u7c7b\u522b\u66b4\u9732\u4e8e\u73af\u6c27\u4e59\u70f7\u2014\u2014\u751a\u81f3\u5728\u6210\u54c1\u98df\u54c1\u4e2d\u2014\u2014\u73af\u6c27\u4e59\u70f7\u542b\u91cf\u8fdc\u9ad8\u4e8e\u5b9a\u91cf\u9650\uff08LOQ\uff09\u3002\u6574\u6279\u98df\u54c1\u4e0d\u5f97\u4e0d\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5982\u4f55\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\"><strong>\u5982\u4f55\u68c0\u6d4b\u73af\u6c27\u4e59\u70f7\uff1f<\/strong><\/h2>\n\n\n\n<p>\u76ee\u524d\u6709\u4e24\u79cd\u68c0\u6d4b\u65b9\u6cd5\u53ef\u7528\u3002<\/p>\n\n\n\n<p>\u7b2c\u4e00\u79cd\u65b9\u6cd5\u57fa\u4e8e1999\u5e7411\u6708\u53d1\u5e03\u7684GC-MS\uff08\u6c14\u76f8\u8272\u8c31-\u8d28\u8c31\uff09\u65b9\u6cd5\u3002[1]<\/p>\n\n\n\n<p>\u8be5\u5fb7\u56fd\u653f\u5e9c\u65b9\u6cd5\u63cf\u8ff0\u4e86\u4e00\u79cd\u5c06\u73af\u6c27\u4e59\u70f7\u548c2-\u6c2f\u4e59\u9187\u4e4b\u548c\u4f5c\u4e3a\u73af\u6c27\u4e59\u70f7\u8fdb\u884c\u6d4b\u5b9a\u7684\u7a0b\u5e8f\u3002\u8be5\u65b9\u6cd5\u57fa\u4e8e2-\u6c2f\u4e59\u9187\u8f6c\u5316\u4e3a\u73af\u6c27\u4e59\u70f7\uff0c\u7136\u540e\u4e0e\u7898\u5316\u7269\u8fdb\u884c\u884d\u751f\u5316\u53cd\u5e94\uff0c\u5e76\u901a\u8fc7\u6c14\u76f8\u8272\u8c31\u6cd5\u68c0\u6d4b\u751f\u6210\u7684\u7898\u5316\u4e8c\u4e59\u9187\uff08Iodidiethanol\uff09\u3002\u6b64\u65b9\u6cd5\u975e\u5e38\u8017\u65f6\uff0c\u5373\u4fbf\u662f\u6709\u7ecf\u9a8c\u7684\u4eba\u4e00\u5929\u4e5f\u53ea\u80fd\u5904\u7406\u516d\u4e2a\u6837\u54c1\u3002\u7136\u800c\uff0c\u8fd9\u662f\u4e00\u79cd\u7ecf\u8fc7\u9a8c\u8bc1\u4e14\u7cbe\u786e\u7684\u65b9\u6cd5\u3002<\/p>\n\n\n\n<p>\u7b2c\u4e8c\u79cd\u65b9\u6cd5\u57fa\u4e8e2020\u5e7412\u6708\u5f00\u53d1\u7684GC-MS\/MS\u65b9\u6cd5\u3002<\/p>\n\n\n\n<p>EtO\u7684\u68c0\u51fa\u9650\u9700\u8981\u8fbe\u52300.05 mg\/kg\u3002\u4e3a\u5b9e\u73b0\u8fd9\u4e00\u76ee\u6807\uff0c\u9700\u8981\u91c7\u7528\u7279\u6b8a\u7684\u6837\u54c1\u524d\u5904\u7406\u65b9\u6cd5\u4ee5\u53ca\u5728SRM\uff08\u5355\u53cd\u5e94\u76d1\u6d4b\u6a21\u5f0f\uff09\u4e0b\u7684GC-MS\/MS\u5206\u6790\u65b9\u6cd5\u3002\u5fb7\u56fd\u65af\u56fe\u52a0\u7279\u7684CVUA\uff08\u5316\u5b66\u4e0e\u517d\u533b\u8c03\u67e5\u5c40\uff09\u4e8e2020\u5e7412\u6708\u53d1\u5e03\u4e86\u4e00\u9879<a href=\"https:\/\/www.eurl-pesticides.eu\/library\/docs\/srm\/EurlSrm_Observation_EO_V1.pdf\"><u>EURL-SRM<\/u><\/a>\u65b9\u6cd5\uff0c\u4f7f\u7528\u4e86<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14800302?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>Thermo Scientific\u2122TRACE\u21221310<\/u><\/a>\u6c14\u76f8\u8272\u8c31\u4eea\u548c<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/tsq9k-vpi?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>Thermo Scientific\u2122 TSQ\u2122 9<\/u><u>6<\/u><u>1<\/u><u>0 GC<\/u><\/a>\u4e09\u91cd\u56db\u6781\u6746\u8d28\u8c31\u4eea\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8ba9\u6211\u4eec\u4ece\u6837\u54c1\u524d\u5904\u7406\u5f00\u59cb\"><strong>\u8ba9\u6211\u4eec\u4ece\u6837\u54c1\u524d\u5904\u7406\u5f00\u59cb<\/strong><\/h2>\n\n\n\n<p>\u5982CVUA\u9488\u5bf9\u73af\u6c27\u4e59\u70f7\u53ca\u5176\u4ee3\u8c22\u4ea7\u72692-\u6c2f\u4e59\u9187\u5206\u6790\u7684\u5355\u6b8b\u7559\u65b9\u6cd5\u6240\u8ff0\uff0c\u91c7\u7528\u4e86QuEChERS EN 15662\u65b9\u6cd5\u548cGC-MS\/MS\u5206\u6790\u6280\u672f\u3002\u56e0\u6b64\uff0c\u53d62\u514b\u6837\u54c1\uff0c\u52a0\u5165\u6807\u51c6\u54c1\u548c\u4e59\u8148\uff08Acetonitrile\uff09\uff0c\u7136\u540e\u5c06\u6837\u54c1\u6da1\u65cb\u632f\u8361\u4e94\u5206\u949f\u3002EN 15662\u63d0\u53d6\u8bd5\u5242\u76d2\u5305\u542b4\u514b\u65e0\u6c34\u786b\u9178\u9541\u30011\u514b\u6c2f\u5316\u94a0\u30011\u514b\u67e0\u6aac\u9178\u4e09\u94a0\u548c500\u6beb\u514b\u67e0\u6aac\u9178\u4e8c\u94a0\u3002\u632f\u8361\u4e00\u5206\u949f\u540e\uff0c\u5c06\u6837\u54c1\u4ee55000 rpm\u79bb\u5fc3\u4e94\u5206\u949f\u3002\u53d61\u6beb\u5347\u4e0a\u6e05\u6db2\u8f6c\u79fb\u5230\u542b\u6709150\u6beb\u514b\u786b\u9178\u9541\u300125\u6beb\u514bPSA\u548c25\u6beb\u514bC18\u7684\u5c0f\u578b\u79bb\u5fc3\u7ba1\u4e2d\uff0c\u6da1\u65cb30\u79d2\u540e\uff0c\u518d\u6b21\u4ee55000 rpm\u79bb\u5fc3\u3002\u6700\u540e\u5c06\u4e0a\u6e05\u6db2\u8f6c\u79fb\u81f3GC\u8fdb\u6837\u74f6\u4e2d\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-gc-ms\u5206\u6790\"><strong>GC-MS\u5206\u6790<\/strong><\/h2>\n\n\n\n<p>\u8fd9\u4e9b\u53c2\u6570\u662f\u4e3a<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/products-and-services\/promotions\/industrial\/unstoppable-gc-ms-analysis.html?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>Thermo Scientific\u2122 ISQ\u2122 7610 GC<\/u><\/a>\u5fb7\u56fd\u98df\u54c1\u68c0\u6d4b\u5b9e\u9a8c\u5ba4\u7684\u5355\u56db\u6781\u6746\u7cfb\u7edf\u5f00\u53d1\u7684\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5206\u6790\u53c2\u6570\"><strong>\u5206\u6790\u53c2\u6570<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8fdb\u6837\u53e3<\/td><td>PTV\uff08\u7a0b\u5e8f\u5347\u6e29\u6c14\u5316\uff09<\/td><\/tr><tr><td>\u8fdb\u6837\u6a21\u5f0f<\/td><td>\u65e0\u5206\u6d41\uff08Splitless\uff09<\/td><\/tr><tr><td>\u8fdb\u6837\u91cf<\/td><td>1\u5fae\u5347<\/td><\/tr><tr><td>\u6d41\u91cf\u63a7\u5236\u6a21\u5f0f<\/td><td>\u6052\u5b9a\u6d41\u91cf<\/td><\/tr><tr><td>\u67f1\u6d41\u91cf<\/td><td>1.00 \u6beb\u5347\/\u5206\u949f<\/td><\/tr><tr><td>\u8f7d\u6c14<\/td><td>6.0\u7ea7\u6c26\u6c14<\/td><\/tr><tr><td>\u603b\u8fd0\u884c\u65f6\u95f4<\/td><td>30 \u5206\u949f<\/td><\/tr><tr><td>\u6c14\u76f8\u8272\u8c31\u7a0b\u5e8f<\/td><td><br>50\u00b0C\uff0c\u4fdd\u63011\u5206\u949f\uff0c\u4ee525\u00b0C\/\u5206\u949f\u5347\u6e29\u81f3200\u00b0C\uff0c\u4fdd\u630123\u5206\u949f<\/td><\/tr><tr><td>\u8272\u8c31\u67f1<\/td><td>Carbowax\uff0c30\u7c73\uff0c0.25\u6beb\u7c73\u5185\u5f84\uff0c0.25\u5fae\u7c73\u819c\u539a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-gc-ms-ms\u53c2\u6570\"><strong>GC-MS\/MS\u53c2\u6570<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u65b9\u6cd5\u7c7b\u578b<\/td><td>\u9009\u62e9\u79bb\u5b50\u76d1\u6d4b\uff08SIM\uff09<\/td><\/tr><tr><td>MS\u4f20\u8f93\u7ebf\u6e29\u5ea6<\/td><td>250\u00b0C<\/td><\/tr><tr><td>\u79bb\u5b50\u6e90\u6e29\u5ea6<\/td><td>250\u00b0C<\/td><\/tr><tr><td>\u7535\u79bb\u65b9\u5f0f<\/td><td>EI\uff08\u7535\u5b50\u8f70\u51fb\uff09<\/td><\/tr><tr><td>m\/z \u7898\u4ee3\u4e8c\u4e59\u9187&nbsp;\u68c0\u6d4b\u79bb\u5b50<\/td><td>\u4fdd\u7559\u65f6\u95f4 6.44 \u5206\u949f&nbsp;127, 128, 141, 142, 172<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u679c\"><strong>\u7ed3\u679c<\/strong><\/h2>\n\n\n\n<p>\u4e0b\u5217\u56fe\u50cf\u5c55\u793a\u4e86\u6309\u7167\u5fb7\u56fd \u00a735 LMBG \u65b9\u6cd5\u5bf9\u829d\u9ebb\u6837\u54c1\u8fdb\u884c\u5206\u6790\u6240\u83b7\u5f97\u7684\u7ed3\u679c\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/090121-Image-2-Fig-1A-1.png\" alt=\"\" class=\"wp-image-12479\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/090121-Image-3-Fig-1B-1.png\" alt=\"\" class=\"wp-image-12480\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\">\u56fe1\uff1a\u5b9e\u9645\u829d\u9ebb\u6837\u54c1\u4e2d\u542b\u67090.406mg\/kg\u73af\u6c27\u4e59\u70f7\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/090121-Image-4-Fig-2-1.png\" alt=\"\" class=\"wp-image-12484\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\">\u56fe2\uff1a\u7898\u4ee3\u4e8c\u4e59\u9187\uff08Iodidiethanol\uff09\u7684\u6821\u51c6\u66f2\u7ebf\u3002\u8be5\u65b9\u6cd5\u7684\u5b9a\u91cf\u4e0b\u9650\uff08LOQ\uff09\u4e3a0.02mg\/kg\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-gc-ms-ms-\u5206\u6790\"><strong>GC-MS\/MS \u5206\u6790<\/strong><\/h2>\n\n\n\n<p>\u65af\u56fe\u52a0\u7279\u7684CVUA\u8be6\u7ec6\u4ecb\u7ecd\u4e86\u4e00\u4e2a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14800302?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>Thermo Scientific\u2122TRACE\u21221310<\/u><\/a>\u6c14\u76f8\u8272\u8c31\u4eea\uff0c<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/tsq9k-vpi?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>Thermo Scientific\u2122 TSQ\u2122 9610 GC<\/u><\/a>\u4e09\u91cd\u56db\u6781\u6746\uff0c<a href=\"s&amp;s_kwcid=AL!3652!3!344648630059!e!!g!!thermo%20triplus%20rsh&amp;gclid=EAIaIQobChMImdWxxJuX8gIVjuCzCh0VXgAhEAAYASAAEgL1jvD_BwE\"><u>\u4ee5\u53caTriPlus RSH\u81ea\u52a8\u8fdb\u6837\u5668\u3002<\/u><\/a><\/p>\n\n\n\n<p>\u5206\u6790\u53ef\u4ee5\u5728\u4ee5\u4e0b\u8272\u8c31\u67f1<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/26085-3320?ce=E.21CMD.PM104.43155.01&amp;cid=E.21CMD.PM104.43155.01\"><u>TG-624 MS\u4e0a\u8fdb\u884c\uff0c<\/u><\/a>30\u7c73\uff0c\u5185\u5f840.32\u6beb\u7c73\uff0c\u819c\u539a0.25\u6beb\u7c73\u3002<\/p>\n\n\n\n<p>\u4ee5\u4e0b\u65b9\u6cd5\u548c\u6570\u636e\u662f\u5728\u8d5b\u9ed8\u98de\u79d1\u5b66\u5b9e\u9a8c\u5ba4\u5f00\u53d1\u7684\uff0c\u57fa\u4e8e\u65af\u56fe\u52a0\u7279CVUA\u7684\u65b9\u6cd5\uff0c\u5e76\u4f7f\u7528\u6dfb\u52a0\u6807\u51c6\u7684\u829d\u9ebb\u7c7d\u6837\u54c1\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8fdb\u6837\u53e3<\/td><td>SSL\uff08\u5206\u6d41\/\u4e0d\u5206\u6d41\uff09<\/td><\/tr><tr><td>\u8fdb\u6837\u6a21\u5f0f<\/td><td>\u5206\u6d41\uff08Split\uff09<\/td><\/tr><tr><td>\u8fdb\u6837\u91cf<\/td><td>1\u5fae\u5347<\/td><\/tr><tr><td>\u8fdb\u6837\u53e3\u6e29\u5ea6<\/td><td>280 \u00b0C<\/td><\/tr><tr><td>\u6d41\u91cf\u63a7\u5236\u6a21\u5f0f<\/td><td>\u6052\u5b9a\u6d41\u91cf<\/td><\/tr><tr><td>\u67f1\u6d41\u91cf<\/td><td>2.00 \u6beb\u5347\/\u5206\u949f<\/td><\/tr><tr><td>\u8f7d\u6c14<\/td><td>6.0\u7ea7\u6c26\u6c14<\/td><\/tr><tr><td>\u5206\u6d41\u6bd4<\/td><td>5:1<\/td><\/tr><tr><td>\u5439\u626b\u6d41\u91cf<\/td><td>5 \u6beb\u5347\/\u5206\u949f<\/td><\/tr><tr><td>\u5206\u6d41\u6d41\u91cf<\/td><td>10 \u6beb\u5347\/\u5206\u949f<\/td><\/tr><tr><td>\u603b\u8fd0\u884c\u65f6\u95f4<\/td><td>25 \u5206\u949f<\/td><\/tr><tr><td>\u6c14\u76f8\u8272\u8c31\u7a0b\u5e8f<\/td><td>40\u00b0C\u4fdd\u63012 min\uff0c\u4ee55\u00b0C\/min\u5347\u81f390\u00b0C\uff1b\u518d\u4ee550\u00b0C\/min\u4ece90\u00b0C\u5347\u81f3225\u00b0C\uff0c\u5e76\u4fdd\u630110.3 min<\/td><\/tr><tr><td>\u65b9\u6cd5\u7c7b\u578b<\/td><td>t-SRM \u6a21\u5f0f<\/td><\/tr><tr><td>MS\u4f20\u8f93\u7ebf\u6e29\u5ea6<\/td><td>230 \u00b0C<\/td><\/tr><tr><td>\u79bb\u5b50\u6e90\u6e29\u5ea6<\/td><td>250\u00b0C<\/td><\/tr><tr><td>\u7535\u79bb\u65b9\u5f0f<\/td><td>EI\uff08\u7535\u5b50\u8f70\u51fb\uff09<\/td><\/tr><tr><td>SRM\u8f6c\u6362<\/td><td>\u73af\u6c27\u4e59\u70f7 Q1 m\/z Q3 m\/z CE (V)&nbsp;44 14 2044 28 544 29 5&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>2-\u6c2f\u4e59\u9187 Q1 m\/z Q3 m\/z CE (V)&nbsp;80 31 580 43 582 31 5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"418\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/WX20260521-003032@2x-1024x418.png\" alt=\"\" class=\"wp-image-2221\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/WX20260521-003032@2x-1024x418.png 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/WX20260521-003032@2x-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/WX20260521-003032@2x-768x314.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/WX20260521-003032@2x.png 1440w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56fe3\uff1a\u57280.025 mg\/kg EtO\u548c2-CE\u6d53\u5ea6\u4e0b\u7684\u603b\u79bb\u5b50\u6d41\u8272\u8c31\u56fe\uff08TIC\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/090121-Image-6-Fig-4-1.png\" alt=\"\" class=\"wp-image-12489\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\">\u56fe4\uff1a\u57280.005-0.2 mg\/kg\u8303\u56f4\u5185\uff0cEtO\u548c2-CE\u7684\u57fa\u8d28\u5339\u914d\u6821\u51c6\u66f2\u7ebf\u3002<\/p>\n\n\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/090121-Image-7-Fig-5-1.png\" alt=\"\" class=\"wp-image-12492\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\">\u56fe5\uff1a\u57280.025 mg\/kg\u57fa\u8d28\u5339\u914d\u6807\u51c6\u4e2d\u89c2\u5bdf\u5230EtO\u548c2-CE\u7684\u7075\u654f\u5ea6\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u8bba\"><strong>\u7ed3\u8bba<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>EtO\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u5173\u6ce8\u7684\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u56e0\u68c0\u6d4b\u51fa&nbsp;EtO \u800c\u88ab\u8feb\u64a4\u5e02\uff0c\u56e0\u6b64\u5bf9EtO\u8fdb\u884c\u63a7\u5236\u7684\u91cd\u8981\u6027\u663e\u800c\u6613\u89c1\u3002<\/li>\n\n\n\n<li>\u5fb7\u56fd\u8054\u90a6\u98ce\u9669\u8bc4\u4f30\u7814\u7a76\u6240\uff08BfR\uff09\u7684\u98ce\u9669\u8bc4\u4f30\u663e\u793a\u4e86\uff0c\u4e3a\u4ec0\u4e48\u6709\u5fc5\u8981\u4fdd\u62a4\u6d88\u8d39\u8005\u514d\u53d7\u5371\u9669\u6c34\u5e73\u7684EtO\u5f71\u54cd\u3002<\/li>\n\n\n\n<li>\u6b63\u5982\u672c\u4e2d\u6240\u793a\uff0c\u76ee\u524d\u5df2\u6709\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u65b9\u6cd5\u80fd\u591f\u5728\u5404\u79cd\u98df\u54c1\u57fa\u8d28\u4e2d\u68c0\u6d4b\u5230\u6240\u9700\u6c34\u5e73\u7684\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u3002<\/li>\n\n\n\n<li>\u00a7 64 LFGB \u65b9\u6cd5\u7684\u4e00\u4e2a\u7f3a\u70b9\u662f\u6837\u54c1\u524d\u5904\u7406\u6240\u9700\u65f6\u95f4\u8f83\u957f\u3002\u6bcf\u5929\u53ea\u80fd\u5904\u7406\u516d\u4e2a\u6837\u54c1\uff0c\u4f46\u8be5\u65b9\u6cd5\u975e\u5e38\u7cbe\u786e\u3002<\/li>\n\n\n\n<li>GC-MS\/MS \u65b9\u6cd5\u7684\u4f18\u70b9\u5728\u4e8e\u91c7\u7528 QuEChERS EN 15662 \u65b9\u6cd5\uff0c\u901f\u5ea6\u5feb\uff0c\u5e76\u4e14\u5bf9\u73af\u6c27\u4e59\u70f7\u53ca\u5176\u4ee3\u8c22\u72692-\u6c2f\u4e59\u9187\u7684\u68c0\u6d4b\u5177\u6709\u8db3\u591f\u7684\u7279\u5f02\u6027\u548c\u7075\u654f\u5ea6\u3002<\/li>\n\n\n\n<li>\u8fd9\u662f\u4e00\u79cd\u5373\u63d2\u5373\u7528\u7684\u65b9\u6cd5\uff0c\u5df2\u5728\u6c14\u76f8\u8272\u8c31\u548c\u98df\u54c1\u68c0\u6d4b\u9886\u57df\u5f97\u5230\u5e7f\u6cdb\u5e94\u7528\u3002<\/li>\n<\/ul>\n\n\n<script type=\"text\/javascript\">\n\/* <![CDATA[ *\/\nvar gform;gform||(document.addEventListener(\"gform_main_scripts_loaded\",function(){gform.scriptsLoaded=!0}),document.addEventListener(\"gform\/theme\/scripts_loaded\",function(){gform.themeScriptsLoaded=!0}),window.addEventListener(\"DOMContentLoaded\",function(){gform.domLoaded=!0}),gform={domLoaded:!1,scriptsLoaded:!1,themeScriptsLoaded:!1,isFormEditor:()=>\"function\"==typeof InitializeEditor,callIfLoaded:function(o){return!(!gform.domLoaded||!gform.scriptsLoaded||!gform.themeScriptsLoaded&&!gform.isFormEditor()||(gform.isFormEditor()&&console.warn(\"The use of gform.initializeOnLoaded() is deprecated in the form editor context and will be removed in Gravity Forms 3.1.\"),o(),0))},initializeOnLoaded:function(o){gform.callIfLoaded(o)||(document.addEventListener(\"gform_main_scripts_loaded\",()=>{gform.scriptsLoaded=!0,gform.callIfLoaded(o)}),document.addEventListener(\"gform\/theme\/scripts_loaded\",()=>{gform.themeScriptsLoaded=!0,gform.callIfLoaded(o)}),window.addEventListener(\"DOMContentLoaded\",()=>{gform.domLoaded=!0,gform.callIfLoaded(o)}))},hooks:{action:{},filter:{}},addAction:function(o,r,e,t){gform.addHook(\"action\",o,r,e,t)},addFilter:function(o,r,e,t){gform.addHook(\"filter\",o,r,e,t)},doAction:function(o){gform.doHook(\"action\",o,arguments)},applyFilters:function(o){return gform.doHook(\"filter\",o,arguments)},removeAction:function(o,r){gform.removeHook(\"action\",o,r)},removeFilter:function(o,r,e){gform.removeHook(\"filter\",o,r,e)},addHook:function(o,r,e,t,n){null==gform.hooks[o][r]&&(gform.hooks[o][r]=[]);var d=gform.hooks[o][r];null==n&&(n=r+\"_\"+d.length),gform.hooks[o][r].push({tag:n,callable:e,priority:t=null==t?10:t})},doHook:function(r,o,e){var t;if(e=Array.prototype.slice.call(e,1),null!=gform.hooks[r][o]&&((o=gform.hooks[r][o]).sort(function(o,r){return o.priority-r.priority}),o.forEach(function(o){\"function\"!=typeof(t=o.callable)&&(t=window[t]),\"action\"==r?t.apply(null,e):e[0]=t.apply(null,e)})),\"filter\"==r)return e[0]},removeHook:function(o,r,t,n){var e;null!=gform.hooks[o][r]&&(e=(e=gform.hooks[o][r]).filter(function(o,r,e){return!!(null!=n&&n!=o.tag||null!=t&&t!=o.priority)}),gform.hooks[o][r]=e)}});\n\/* ]]> *\/\n<\/script>\n\n                <div class='gf_browser_gecko gform_wrapper gravity-theme gform-theme--no-framework' data-form-theme='gravity-theme' data-form-index='0' id='gform_wrapper_3' >\n                        <div class='gform_heading'>\n                            <h2 class=\"gform_title\">\u8054\u7cfb\u6211\u4eec\/Contact Us<\/h2>\n                            <p class='gform_description'><\/p>\n                        <\/div><form method='post' enctype='multipart\/form-data'  id='gform_3'  action='\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/2211\/' data-formid='3' novalidate>\n                        <div class='gform-body gform_body'><div id='gform_fields_3' class='gform_fields top_label form_sublabel_above description_above validation_below'><fieldset id=\"field_3_1\" class=\"gfield gfield--type-name gfield--input-type-name gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><legend class='gfield_label gform-field-label gfield_label_before_complex' >\u59d3\u540d<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/legend><div class='ginput_complex ginput_container ginput_container--name no_prefix has_first_name no_middle_name has_last_name no_suffix gf_name_has_2 ginput_container_name gform-grid-row' id='input_3_1'>\n                            \n                            <span id='input_3_1_3_container' class='name_first gform-grid-col gform-grid-col--size-auto' >\n                                                    <label for='input_3_1_3' class='gform-field-label gform-field-label--type-sub '>\u59d3<\/label>\n                                                    <input type='text' name='input_1.3' id='input_3_1_3' value=''   aria-required='true'    autocomplete=\"given-name\" \/>\n                                                <\/span>\n                            \n                            <span id='input_3_1_6_container' class='name_last gform-grid-col gform-grid-col--size-auto' >\n                                                            <label for='input_3_1_6' class='gform-field-label gform-field-label--type-sub '>\u540d<\/label>\n                                                            <input type='text' name='input_1.6' id='input_3_1_6' value=''   aria-required='true'    autocomplete=\"family-name\" \/>\n                                                        <\/span>\n                            \n                        <\/div><\/fieldset><div id=\"field_3_2\" class=\"gfield gfield--type-email gfield--input-type-email gfield--width-full gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><label class='gfield_label gform-field-label' for='input_3_2'>Email<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/label><div class='ginput_container ginput_container_email'>\n                            <input name='input_2' id='input_3_2' type='email' value='' class='medium'    aria-required=\"true\" aria-invalid=\"false\"  \/>\n                        <\/div><\/div><div id=\"field_3_4\" class=\"gfield gfield--type-text gfield--input-type-text gfield--width-half gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><label class='gfield_label gform-field-label' for='input_3_4'>\u5355\u4f4d\/\u5b66\u6821<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/label><div class='ginput_container ginput_container_text'><input name='input_4' id='input_3_4' type='text' value='' class='large'     aria-required=\"true\" aria-invalid=\"false\"   \/><\/div><\/div><div id=\"field_3_5\" class=\"gfield gfield--type-number gfield--input-type-number gfield--width-half gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><label class='gfield_label gform-field-label' for='input_3_5'>\u7535\u8bdd\u53f7\u7801<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/label><div class='ginput_container ginput_container_number'><input name='input_5' id='input_3_5' type='number' step='any'   value='' class='large'     aria-required=\"true\" aria-invalid=\"false\"  \/><\/div><\/div><div id=\"field_3_3\" class=\"gfield gfield--type-textarea gfield--input-type-textarea gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><label class='gfield_label gform-field-label' for='input_3_3'>\u5177\u4f53\u95ee\u9898\u6216\u5efa\u8bae<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/label><div class='ginput_container ginput_container_textarea'><textarea name='input_3' id='input_3_3' class='textarea small'   maxlength='600'  aria-required=\"true\" aria-invalid=\"false\"   rows='10' cols='50'><\/textarea><\/div><\/div><fieldset id=\"field_3_6\" class=\"gfield gfield--type-consent gfield--type-choice gfield--input-type-consent gfield--width-full gfield_contains_required field_sublabel_above gfield--no-description field_description_above field_validation_below gfield_visibility_visible\"  ><legend class='gfield_label gform-field-label gfield_label_before_complex' >\u540c\u610f<span class=\"gfield_required\"><span class=\"gfield_required gfield_required_text\">(Required)<\/span><\/span><\/legend><div class='ginput_container ginput_container_consent'><input name='input_6.1' id='input_3_6_1' type='checkbox' value='1'   aria-required=\"true\" aria-invalid=\"false\"   \/> <label class=\"gform-field-label gform-field-label--type-inline gfield_consent_label\" for='input_3_6_1' >\u6211\u5df2\u5b8c\u6574\u9605\u8bfb\u5e76\u540c\u610f\u8d5b\u9ed8\u98de\u300a\u4e2a\u4eba\u4fe1\u606f\u4fdd\u62a4\u653f\u7b56\u300b\uff08https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/privacy-policy.html\uff09\uff0c\u5e76\u540c\u610f\u8d5b\u9ed8\u98de\u6309\u7167\u8be5\u653f\u7b56\u5904\u7406\u6211\u7684\u4e2a\u4eba\u4fe1\u606f\uff0c\u5e0c\u671b\u63a5\u6536\u8d5b\u9ed8\u98de\u548c\u54c1\u724c\u3001\u4ea7\u54c1\u548c\u670d\u52a1\u76f8\u5173\u8425\u9500\u548c\u5ba3\u4f20\u4fe1\u606f\u3002<\/label><input type='hidden' name='input_6.2' value='\u6211\u5df2\u5b8c\u6574\u9605\u8bfb\u5e76\u540c\u610f\u8d5b\u9ed8\u98de\u300a\u4e2a\u4eba\u4fe1\u606f\u4fdd\u62a4\u653f\u7b56\u300b\uff08https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/privacy-policy.html\uff09\uff0c\u5e76\u540c\u610f\u8d5b\u9ed8\u98de\u6309\u7167\u8be5\u653f\u7b56\u5904\u7406\u6211\u7684\u4e2a\u4eba\u4fe1\u606f\uff0c\u5e0c\u671b\u63a5\u6536\u8d5b\u9ed8\u98de\u548c\u54c1\u724c\u3001\u4ea7\u54c1\u548c\u670d\u52a1\u76f8\u5173\u8425\u9500\u548c\u5ba3\u4f20\u4fe1\u606f\u3002' class='gform_hidden' \/><input type='hidden' name='input_6.3' value='2' class='gform_hidden' \/><\/div><\/fieldset><\/div><\/div>\n        <div class='gform-footer gform_footer top_label'> <input type='submit' id='gform_submit_button_3' class='gform_button button gform-button--width-full' onclick='gform.submission.handleButtonClick(this);' data-submission-type='submit' value='\u63d0\u4ea4'  \/> \n            <input type='hidden' class='gform_hidden' name='gform_submission_method' data-js='gform_submission_method_3' value='postback' \/>\n            <input type='hidden' class='gform_hidden' name='gform_theme' data-js='gform_theme_3' id='gform_theme_3' value='gravity-theme' \/>\n            <input type='hidden' class='gform_hidden' name='gform_style_settings' data-js='gform_style_settings_3' id='gform_style_settings_3' value='{&quot;inputPrimaryColor&quot;:&quot;#204ce5&quot;}' \/>\n            <input type='hidden' class='gform_hidden' name='is_submit_3' value='1' \/>\n            <input type='hidden' class='gform_hidden' name='gform_submit' value='3' \/>\n            \n            <input type='hidden' class='gform_hidden' name='gform_currency' data-currency='USD' value='Z5HF5uWw\/VdA6P\/dUQpuD6oGDolyDsL5yM+pQhDiv7ocVxQsSuuT6ZtyMSSVq4fzB6bEYze8sRvmeMhhBNVNiXyJ4J4ZM\/tTcmoMwN9nVF3WL4E=' \/>\n            <input type='hidden' class='gform_hidden' name='gform_unique_id' value='' \/>\n            <input type='hidden' class='gform_hidden' name='state_3' value='WyJ7XCI2LjFcIjpcIjYxYWM3MDVmMzE5MjNlMzU4YmM4YzAyYzJjYjYwYWU3XCIsXCI2LjJcIjpcImJkNmI1N2YyYWVjNjdlZmJjZmJkZjhjODk3YWU1MzUxXCIsXCI2LjNcIjpcImY1NzlmMGQ5MzgyM2IzNWUwYjk1NjM4ZjAzZWRiMzI1XCJ9IiwiMWUzNzFmOGM2MjBkZmUxOTFlNzVjMzk0ZjcwZGUwODQiXQ==' \/>\n            <input type='hidden' autocomplete='off' class='gform_hidden' name='gform_target_page_number_3' id='gform_target_page_number_3' value='0' \/>\n            <input type='hidden' autocomplete='off' class='gform_hidden' name='gform_source_page_number_3' id='gform_source_page_number_3' value='1' \/>\n            <input type='hidden' name='gform_field_values' value='' \/>\n            \n        <\/div>\n                        <input type=\"hidden\" id=\"ct_checkjs_a86c450b76fb8c371afead6410d55534\" name=\"ct_checkjs\" value=\"0\" \/><script type=\"text\/javascript\">\/* <![CDATA[ *\/setTimeout(function(){var ct_input_name = \"ct_checkjs_a86c450b76fb8c371afead6410d55534\";if (document.getElementById(ct_input_name) !== null) {var ct_input_value = document.getElementById(ct_input_name).value;document.getElementById(ct_input_name).value = document.getElementById(ct_input_name).value.replace(ct_input_value, '2141096235');}}, 1000);\/* ]]> *\/<\/script><input\n                    class=\"apbct_special_field apbct_email_id__gravity_form\"\n                    name=\"apbct__email_id__gravity_form\"\n                    aria-label=\"apbct__label_id__gravity_form\"\n                    type=\"text\" size=\"30\" maxlength=\"200\" autocomplete=\"off\"\n                    value=\"\"\n                \/><\/form>\n                        <\/div><script type=\"text\/javascript\">\n\/* <![CDATA[ *\/\n gform.initializeOnLoaded( function() {gformInitSpinner( 3, 'https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/plugins\/gravityforms\/images\/spinner.svg', true );jQuery('#gform_ajax_frame_3').on('load',function(){var contents = jQuery(this).contents().find('*').html();var is_postback = contents.indexOf('GF_AJAX_POSTBACK') >= 0;if(!is_postback){return;}var form_content = jQuery(this).contents().find('#gform_wrapper_3');var is_confirmation = jQuery(this).contents().find('#gform_confirmation_wrapper_3').length > 0;var is_redirect = contents.indexOf('gformRedirect(){') >= 0;var is_form = form_content.length > 0 && ! is_redirect && ! is_confirmation;var mt = parseInt(jQuery('html').css('margin-top'), 10) + parseInt(jQuery('body').css('margin-top'), 10) + 100;if(is_form){jQuery('#gform_wrapper_3').html(form_content.html());if(form_content.hasClass('gform_validation_error')){jQuery('#gform_wrapper_3').addClass('gform_validation_error');} else {jQuery('#gform_wrapper_3').removeClass('gform_validation_error');}setTimeout( function() { \/* delay the scroll by 50 milliseconds to fix a bug in chrome *\/  }, 50 );if(window['gformInitDatepicker']) {gformInitDatepicker();}if(window['gformInitPriceFields']) {gformInitPriceFields();}var current_page = jQuery('#gform_source_page_number_3').val();gformInitSpinner( 3, 'https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/plugins\/gravityforms\/images\/spinner.svg', true );jQuery(document).trigger('gform_page_loaded', [3, current_page]);window['gf_submitting_3'] = false;}else if(!is_redirect){var confirmation_content = jQuery(this).contents().find('.GF_AJAX_POSTBACK').html();if(!confirmation_content){confirmation_content = contents;}jQuery('#gform_wrapper_3').replaceWith(confirmation_content);jQuery(document).trigger('gform_confirmation_loaded', [3]);window['gf_submitting_3'] = false;wp.a11y.speak(jQuery('#gform_confirmation_message_3').text());}else{jQuery('#gform_3').append(contents);if(window['gformRedirect']) {gformRedirect();}}jQuery(document).trigger(\"gform_pre_post_render\", [{ formId: \"3\", currentPage: \"current_page\", abort: function() { this.preventDefault(); } }]);        if (event && event.defaultPrevented) {                return;        }        const gformWrapperDiv = document.getElementById( \"gform_wrapper_3\" );        if ( gformWrapperDiv ) {            const visibilitySpan = document.createElement( \"span\" );            visibilitySpan.id = \"gform_visibility_test_3\";            gformWrapperDiv.insertAdjacentElement( \"afterend\", visibilitySpan );        }        const visibilityTestDiv = document.getElementById( \"gform_visibility_test_3\" );        let postRenderFired = false;        function triggerPostRender() {            if ( postRenderFired ) {                return;            }            postRenderFired = true;            gform.core.triggerPostRenderEvents( 3, current_page );            if ( visibilityTestDiv ) {                visibilityTestDiv.parentNode.removeChild( visibilityTestDiv );            }        }        function debounce( func, wait, immediate ) {            var timeout;            return function() {                var context = this, args = arguments;                var later = function() {                    timeout = null;                    if ( !immediate ) func.apply( context, args );                };                var callNow = immediate && !timeout;                clearTimeout( timeout );                timeout = setTimeout( later, wait );                if ( callNow ) func.apply( context, args );            };        }        const debouncedTriggerPostRender = debounce( function() {            triggerPostRender();        }, 200 );        if ( visibilityTestDiv && visibilityTestDiv.offsetParent === null ) {            const observer = new MutationObserver( ( mutations ) => {                mutations.forEach( ( mutation ) => {                    if ( mutation.type === 'attributes' && visibilityTestDiv.offsetParent !== null ) {                        debouncedTriggerPostRender();                        observer.disconnect();                    }                });            });            observer.observe( document.body, {                attributes: true,                childList: false,                subtree: true,                attributeFilter: [ 'style', 'class' ],            });        } else {            triggerPostRender();        }    } );} ); \n\/* ]]> *\/\n<\/script>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5f15\u8a00 \u73af\u6c27\u4e59\u70f7\uff08Ethylene Oxide\uff0cEtO\uff09\u81ea1991\u5e74\u4ee5\u6765\u5728\u6b27\u76df\u88ab\u7981\u6b62\u4f7f\u7528\u3002\u50cf\u5fb7\u56fd\u8fd9\u6837\u7684\u56fd\u5bb6\u65e9\u57281<\/p>\n","protected":false},"author":1852,"featured_media":2220,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[49],"tags":[215],"division":[50],"class_list":{"0":"post-2211","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-49","8":"tag-215","9":"division-cmd","10":"entry"},"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1\" \/>\n<meta property=\"og:description\" content=\"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-17T02:36:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-17T02:36:48+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"999\" \/>\n\t<meta property=\"og:image:height\" content=\"666\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1\",\"datePublished\":\"2026-06-17T02:36:46+00:00\",\"dateModified\":\"2026-06-17T02:36:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/\"},\"wordCount\":160,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/05\\\/13442-og.jpg\",\"keywords\":[\"\u73af\u6c27\u4e59\u70f7\"],\"articleSection\":[\"\u8272\u8c31\u4e0e\u8d28\u8c31\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/\",\"name\":\"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/05\\\/13442-og.jpg\",\"datePublished\":\"2026-06-17T02:36:46+00:00\",\"dateModified\":\"2026-06-17T02:36:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/05\\\/13442-og.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/05\\\/13442-og.jpg\",\"width\":999,\"height\":666},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/","og_locale":"zh_CN","og_type":"article","og_title":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1","og_description":"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-06-17T02:36:46+00:00","article_modified_time":"2026-06-17T02:36:48+00:00","og_image":[{"width":999,"height":666,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1","datePublished":"2026-06-17T02:36:46+00:00","dateModified":"2026-06-17T02:36:48+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/"},"wordCount":160,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg","keywords":["\u73af\u6c27\u4e59\u70f7"],"articleSection":["\u8272\u8c31\u4e0e\u8d28\u8c31"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/","name":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg","datePublished":"2026-06-17T02:36:46+00:00","dateModified":"2026-06-17T02:36:48+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u73af\u6c27\u4e59\u70f7\uff08EtO\uff09\u5728\u6b27\u76df\u8d8a\u6765\u8d8a\u6210\u4e3a\u4e00\u4e2a\u70ed\u95e8\u8bdd\u9898\u3002\u7531\u4e8e\u6bcf\u5929\u90fd\u6709\u5927\u91cf\u4ea7\u54c1\u9700\u8981\u4ece\u5e02\u573a\u4e0a\u64a4\u56de\uff0c\u5bf9\u73af\u6c27\u4e59\u70f7\u7684\u76d1\u7ba1\u5df2\u7ecf\u975e\u5e38\u660e\u786e\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg","width":999,"height":666},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/toxic-gases-in-food-and-the-threat-of-ethylene-oxide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u98df\u54c1\u4e2d\u7684\u6709\u6bd2\u6c14\u4f53\u4e0e\u73af\u6c27\u4e59\u70f7\u7684\u5a01\u80c1"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":49,"label":"\u8272\u8c31\u4e0e\u8d28\u8c31"}],"post_tag":[{"value":215,"label":"\u73af\u6c27\u4e59\u70f7"}],"division":[{"value":50,"label":"CMD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/05\/13442-og.jpg",760,507,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":49,"name":"\u8272\u8c31\u4e0e\u8d28\u8c31","slug":"%e8%89%b2%e8%b0%b1%e4%b8%8e%e8%b4%a8%e8%b0%b1","term_group":0,"term_taxonomy_id":49,"taxonomy":"category","description":"","parent":0,"count":38,"filter":"raw","meta":[],"cat_ID":49,"category_count":38,"category_description":"","cat_name":"\u8272\u8c31\u4e0e\u8d28\u8c31","category_nicename":"%e8%89%b2%e8%b0%b1%e4%b8%8e%e8%b4%a8%e8%b0%b1","category_parent":0}],"tag_info":[{"term_id":215,"name":"\u73af\u6c27\u4e59\u70f7","slug":"%e7%8e%af%e6%b0%a7%e4%b9%99%e7%83%b7","term_group":0,"term_taxonomy_id":215,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/2211","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=2211"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/2211\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/2220"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=2211"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=2211"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=2211"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=2211"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}