{"id":237,"date":"2026-02-24T03:04:16","date_gmt":"2026-02-24T03:04:16","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=237"},"modified":"2026-03-10T06:51:14","modified_gmt":"2026-03-10T06:51:14","slug":"tips-to-optimize-sgrna-design","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/","title":{"rendered":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/Tips-to-optimize-sgRNA-design_350x350.png\" alt=\"TrueDesign CRISPR Cas9 Genome Editor\" class=\"wp-image-3957\" title=\"TrueDesign Genome Editor\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u8bbe\u8ba1\u6709\u6548\u7684CRISPR\u5b9e\u9a8c\u6d89\u53ca\u591a\u4e2a\u6b65\u9aa4\uff0c\u5176\u4e2d\u4e4b\u4e00\u5c31\u662f\u6709\u6548\u8bbe\u8ba1\u5355\u94fe\u5411\u5bfcRNA\uff08sgRNA\uff09\u3002sgRNA\u662f\u53ef\u7f16\u7a0b\u5e8f\u5217\uff0c\u53ef\u5f15\u5bfc\u6838\u9178\u9176\uff08\u5982CRISPR-Cas9\uff09\u5230\u8fbe\u7279\u5b9a\u7684DNA\u9776\u70b9\u3002\u9ad8\u6548\u7684sgRNA\u8bbe\u8ba1\u5bf9\u4e8e\u6267\u884c\u7cbe\u786e\u7684\u57fa\u56e0\u7ec4\u7f16\u8f91\u5b9e\u9a8c\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48sgrna\u8bbe\u8ba1\u5f88\u91cd\u8981\">\u4e3a\u4ec0\u4e48sgRNA\u8bbe\u8ba1\u5f88\u91cd\u8981\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u4f18\u5316sgRNA\u8bbe\u8ba1\uff0c\u5e94\u8003\u8651\u4ee5\u4e0b\u56e0\u7d20\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>PAM\u517c\u5bb9\u6027\uff1a<\/strong>\u539f\u95f4\u9694\u533a\u76f8\u90bb\u57fa\u5e8f\uff08PAM\uff09\u662fCas\u86cb\u767d\u8bc6\u522b\u3001\u7ed3\u5408\u76ee\u6807DNA\u5e76\u542f\u52a8\u5207\u5272\u8fc7\u7a0b\u6240\u5fc5\u9700\u7684\u3002\u4e0d\u540c\u7684Cas\u53d8\u4f53\u8bc6\u522b\u4e0d\u540c\u7684PAM\u5e8f\u5217\uff08\u4f8b\u5982\uff0cCas9\u8bc6\u522bNGG\uff09\u3002\u786e\u8ba4\u60a8\u7684\u9776\u70b9\u4f4d\u70b9\u5305\u542b\u517c\u5bb9\u7684PAM\u975e\u5e38\u91cd\u8981\u3002\u5982\u679c\u60a8\u7684\u9776\u70b9\u7f3a\u5c11\u6240\u9700\u7684PAM\u5e8f\u5217\uff0c\u53ef\u4ee5\u8003\u8651\u4f7f\u7528<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/genome-editing\/talens.html?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_awa_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">TALENs\uff08\u8f6c\u5f55\u6fc0\u6d3b\u56e0\u5b50\u6837\u6548\u5e94\u7269\u6838\u9178\u9176\uff09<\/a>\u6765\u5b9e\u73b0\u60a8\u7684\u7f16\u8f91\u76ee\u6807\u3002TrueDesign Genome Editor\u4e5f\u53ef\u4ee5\u4e3a\u611f\u5174\u8da3\u533a\u57df\u8bbe\u8ba1TALEN\u5bf9\u3002<br><\/li>\n\n\n\n<li><strong>\u9776\u5411\u6d3b\u6027\uff1a<\/strong>sgRNA\u7684\u6548\u7387\u7531\u5176\u5e8f\u5217\u3001\u5468\u56f4DNA\u73af\u5883\u4ee5\u53ca\u5176\u4ed6\u7279\u5f81\u51b3\u5b9a\uff0c\u5982sgRNA:DNA\u7194\u89e3\u6e29\u5ea6\u3001\u6298\u53e0\u95f4\u9694\u533a\u5e8f\u5217\u7684\u6700\u5c0f\u81ea\u7531\u80fd\u548c\u67d3\u8272\u8d28\u53ef\u53ca\u6027\u3002\u57fa\u4e8e\u8fd9\u4e9b\u56e0\u7d20\uff0c\u5df2\u7ecf\u5f00\u53d1\u51fa\u591a\u79cd\u673a\u5668\u5b66\u4e60\u7b97\u6cd5\uff0c\u7528\u4e8e\u9884\u6d4bsgRNA\u7684\u9776\u5411\u6d3b\u6027\u3002\u5728\u8bbe\u8ba1\u9488\u5bf9\u76ee\u6807\u533a\u57df\u7684sgRNA\u65f6\uff0c\u9884\u6d4b\u51fa\u7684\u9776\u5411\u6d3b\u6027\u8bc4\u5206\u53ef\u4ee5\u5e2e\u52a9\u7528\u6237\u9009\u62e9\u6700\u4f73sgRNA\u3002\u5728TrueDesign Genome Editor\u4e2d\uff0c\u6211\u4eec\u4f7f\u7528Rule Set 3 <sup>[1]<\/sup>\u6765\u786e\u5b9a\u9776\u5411\u8bc4\u5206\u3002<br><\/li>\n\n\n\n<li><strong>\u8131\u9776\u6d3b\u6027\uff1a<\/strong>\u5728\u8bbe\u8ba1\u8fc7\u7a0b\u4e2d\u8fd8\u5e94\u8bc4\u4f30sgRNA\u7684\u8131\u9776\u8c31\u3002\u8fd9\u5305\u62ec\u626b\u63cf\u76ee\u6807\u57fa\u56e0\u7ec4\u4e2d\u4e0e\u76ee\u6807\u5e8f\u5217\u76f8\u4f3c\u7684\u533a\u57df\u3002\u8131\u9776\u641c\u7d22\u5e94\u8003\u8651\u9519\u914d\uff0c\u56e0\u4e3a\u50cfCas9\u8fd9\u6837\u7684\u6838\u9178\u9176\u5141\u8bb8sgRNA\u5373\u4f7f\u5b58\u5728\u9519\u914d\u4e5f\u80fd\u7ed3\u5408\uff0c\u4ece\u800c\u5bfc\u81f4\u610f\u5916\u7f16\u8f91\u3002\u6b64\u5916\uff0cCas9\u8fd8\u80fd\u8bc6\u522bNAG\u548cNGA\u7b49\u66ff\u4ee3PAM\u5e8f\u5217\uff0c\u8fd9\u4e9b\u4e5f\u5e94\u7eb3\u5165\u8131\u9776\u5206\u6790\uff0c\u4ee5\u5168\u9762\u8bc4\u4f30\u6f5c\u5728\u7684\u8131\u9776\u6548\u5e94\u3002TrueDesign Genome Editor\u901a\u8fc7\u5141\u8bb8sgRNA\u5e8f\u5217\u6700\u591a\u67093\u4e2a\u9519\u914d\uff0c\u5e76\u5305\u542bNGG\u3001NGA\u548cNAG PAM\u5e8f\u5217\u6765\u8bc4\u4f30\u8131\u9776\u4f4d\u70b9\u3002TrueDesign Genome Editor\u4f7f\u7528\u5207\u5272\u9891\u7387\u5224\u5b9a\uff08CFD\uff09\u8bc4\u5206<sup>[2]<\/sup>\u5bf9\u8131\u9776\u4f4d\u70b9\u8fdb\u884c\u8bc4\u5206\uff0c\u5e76\u6ce8\u91ca\u8131\u9776\u4f4d\u70b9\u7684\u4f4d\u7f6e\uff0c\u6307\u660e\u5176\u662f\u5426\u4f4d\u4e8e\u57fa\u56e0\u7684\u5916\u663e\u5b50\u6216\u5185\u542b\u5b50\uff0c\u4ee5\u53ca\u8be5\u57fa\u56e0\u662f\u5426\u4e3a\u764c\u57fa\u56e0\u6216\u80bf\u7624\u6291\u5236\u57fa\u56e0\u3002\u8fd9\u4e9b\u7ec6\u8282\u53ef\u4ee5\u5e2e\u52a9\u7528\u6237\u9009\u62e9\u5177\u6709\u8f83\u5c11\u8131\u9776\u4f4d\u70b9\u7684sgRNA\u3001\u5177\u6709\u4f4eCFD\u8bc4\u5206\u7684\u8131\u9776\u4f4d\u70b9\u7684sgRNA\u3001\u5177\u6709\u5185\u542b\u5b50\u6216\u57fa\u56e0\u95f4\u533a\u8131\u9776\u4f4d\u70b9\u7684sgRNA\uff0c\u6216\u8fd9\u4e9b\u56e0\u7d20\u7684\u7ec4\u5408\u3002<br><\/li>\n\n\n\n<li><strong>\u8ddd\u79bb\u7f16\u8f91\u4f4d\u70b9\uff1a<\/strong>\u76ee\u6807\u5e8f\u5217\u8ddd\u79bb\u671f\u671b\u7f16\u8f91\u4f4d\u70b9\u7684\u7075\u6d3b\u6027\u53d6\u51b3\u4e8e\u5b9e\u9a8c\u7c7b\u578b\u3002\u5bf9\u4e8e\u6572\u9664\u5b9e\u9a8c\uff0c\u7406\u60f3\u60c5\u51b5\u4e0b\u5e94\u5c06sgRNA\u8bbe\u8ba1\u4e3a\u9488\u5bf9\u57fa\u56e0\u65e9\u671f\u5916\u663e\u5b50\u7684\u5e8f\u5217\u3002\u5bf9\u4e8e\u6572\u5165\u5b9e\u9a8c\uff0c\u5e94\u5c06sgRNA\u8bbe\u8ba1\u4e3a\u5c3d\u53ef\u80fd\u9760\u8fd1\u671f\u671b\u63d2\u5165\u4f4d\u70b9\u3002\u9664\u4e86sgRNA\u6d3b\u6027\u4e4b\u5916\uff0c\u6572\u5165\u6548\u7387\u8fd8\u53d6\u51b3\u4e8e\u6572\u5165\u7247\u6bb5\u957f\u5ea6\u4ee5\u53ca\u63d2\u5165\u4f4d\u70b9\u4e0esgRNA\u5207\u5272\u4f4d\u70b9\u4e4b\u95f4\u7684\u8ddd\u79bb\u3002\u5bf9\u4e8e\u540c\u6e90\u81c2\u8f83\u77ed\u7684\u63d2\u5165\u5e8f\u5217\uff0c\u5982\u679csgRNA\u5207\u5272\u4f4d\u70b9\u8ddd\u79bb\u63d2\u5165\u4f4d\u70b9\u8d85\u8fc710 bp\uff0c\u5219\u6572\u5165\u6548\u7387\u8f83\u4f4e\u3002\u7136\u800c\uff0c\u5bf9\u4e8e\u540c\u6e90\u81c2\u8f83\u957f\u7684\u5e8f\u5217\uff0c\u5373\u4f7f\u5207\u5272\u4f4d\u70b9\u8ddd\u79bb\u671f\u671b\u63d2\u5165\u4f4d\u70b9\u8fbe40 bp\uff0c\u4e5f\u80fd\u83b7\u5f97\u66f4\u9ad8\u6548\u7387\u3002<br><\/li>\n\n\n\n<li><strong>\u53d8\u5f02\u91cd\u53e0\uff1a<\/strong>\u4f7f\u7528\u53c2\u8003\u57fa\u56e0\u7ec4\u8bbe\u8ba1\u7684sgRNA\u53ef\u80fd\u7531\u4e8e\u9057\u4f20\u53d8\u5f02\u800c\u964d\u4f4e\u6709\u6548\u6027\u548c\u7279\u5f02\u6027\u3002\u9057\u4f20\u53d8\u5f02\u53ef\u80fd\u5bfc\u81f4PAM\u4f4d\u70b9\u88ab\u7834\u574f\u3001\u65b0PAM\u4f4d\u70b9\u4ea7\u751f\u6216\u5728\u76ee\u6807\u5e8f\u5217\u4e2d\u5f15\u5165\u9519\u914d\u3002\u56e0\u6b64\uff0c\u5728\u8bbe\u8ba1sgRNA\u65f6\uff0c\u5e94\u8003\u8651\u7279\u5b9a\u76ee\u6807\u4eba\u7fa4\uff08\u5982\u5df2\u77e5\uff09\u6216\u6574\u4f53\u4eba\u7fa4\u4e2d\u7684\u9057\u4f20\u53d8\u5f02\u60c5\u51b5\u3002TrueDesign Genome Editor\u53ef\u5728\u5f15\u5bfc\u8bbe\u8ba1\u8fc7\u7a0b\u4e2d\u8f7b\u677e\u53ef\u89c6\u5316\u9057\u4f20\u53d8\u5f02\uff0c\u5e76\u5141\u8bb8\u7528\u6237\u5728\u8fdb\u884c\u8131\u9776\u641c\u7d22\u65f6\u5305\u542b\u9057\u4f20\u53d8\u5f02\u4fe1\u606f\u3002<a id=\"_msocom_1\"><\/a><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u9a8c\u8bc1sgrna\u8bbe\u8ba1\">\u9a8c\u8bc1sgRNA\u8bbe\u8ba1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u867d\u7136\u53ef\u4ee5\u4f7f\u7528\u591a\u79cd\u7b97\u6cd5\u6765\u8bbe\u8ba1\u5e76\u9009\u62e9\u6700\u4f73\u5f15\u5bfcRNA\uff0c\u4f46\u6700\u7ec8\u901a\u8fc7\u529f\u80fd\u6d4b\u8bd5\u624d\u662f\u6700\u6743\u5a01\u7684\u65b9\u6cd5\u7528\u4e8e<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/genome-editing\/crispr-validation.html?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_awa_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">\u9a8c\u8bc1<\/a>\u3002\u7b97\u6cd5\u65e8\u5728\u5177\u6709\u9884\u6d4b\u6027\uff0c\u4f46\u8bf8\u5982\u7ec6\u80de\u73af\u5883\u548c\u9012\u9001\u65b9\u5f0f\u7b49\u56e0\u7d20\u4f1a\u663e\u8457\u5f71\u54cdsgRNA\u7684\u6548\u7387\u3002\u6211\u4eec\u5efa\u8bae\u5bf9\u60a8\u7684sgRNA\u8fdb\u884c\u529f\u80fd\u6027\u6d4b\u8bd5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9a8c\u8bc1\u662f\u786e\u4fdd\u60a8\u7684sgRNA\u529f\u80fd\u6027\u7684\u5173\u952e\u3002\u5728\u6d4b\u91cfsgRNA\u6548\u7387\u65f6\uff0c\u62e5\u6709\u5408\u9002\u7684<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/genome-editing\/crispr-controls.html?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_awa_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">\u9633\u6027\u3001\u9634\u6027\u548c\u9012\u9001\u5bf9\u7167\u7ec4<\/a>\u81f3\u5173\u91cd\u8981\u3002\u53ef\u4ee5\u901a\u8fc7\u591a\u79cd\u65b9\u5f0f\u6d4b\u91cfsgRNA\u7684\u6548\u7387\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>T7\u6838\u9178\u9176\u68c0\u6d4b\u6cd5\uff1a<\/strong>\u53ef\u4f7f\u7528<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A24372?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_pur_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">Invitrogen GeneArt\u57fa\u56e0\u7ec4\u5207\u5272\u68c0\u6d4b\uff08GCD\uff09\u8bd5\u5242\u76d2<\/a>\u5feb\u901f\u4e14\u53ef\u9760\u5730\u786e\u8ba4\u60a8\u7684sgRNA\u7f16\u8f91\u6548\u7387\u3002TrueDesign Genome Editor\u4f1a\u4e3a\u60a8\u9009\u62e9\u7684sgRNA\u8bbe\u8ba1GCD\u5f15\u7269\u3002<br><\/li>\n\n\n\n<li><strong>\u6d4b\u5e8f\uff1a<\/strong>Sanger\u6216\u4e0b\u4e00\u4ee3\u6d4b\u5e8f\u53ef\u7528\u4e8e\u786e\u5b9asgRNA\u7684\u6548\u7387\u4ee5\u53ca\u76ee\u6807\u533a\u57df\u7684\u7f16\u8f91\u7c7b\u578b\u3002\u63d2\u5165\u6216\u7f3a\u5931\u5bfc\u81f4\u79fb\u7801\u7a81\u53d8\u6216\u526a\u63a5\u4f4d\u70b9\u7834\u574f\u53ef\u80fd\u5bfc\u81f4\u57fa\u56e0\u6572\u9664\u3002\u5982\u679c\u8fdb\u884c\u6572\u5165\u5b9e\u9a8c\uff0c\u6d4b\u5e8f\u53ef\u4ee5\u786e\u8ba4\u9884\u671f\u6a21\u677f\u662f\u5426\u6210\u529f\u63d2\u5165\u5230\u76ee\u6807\u4f4d\u7f6e\u3002TrueDesign Genome Editor\u4e5f\u4f1a\u4e3a\u7f16\u8f91\u4f4d\u70b9\u7684\u6d4b\u5e8f\u8bbe\u8ba1\u5f15\u7269\u3002<br><\/li>\n\n\n\n<li><strong>\u6d41\u5f0f\u7ec6\u80de\u672f\uff1a<\/strong>\u5728\u7531\u4e8e\u57fa\u56e0\u7ec4\u7f16\u8f91\u800c\u9884\u671f\u51fa\u73b0\u7279\u5b9a\u8868\u578b\u53d8\u5316\u7684\u7ec6\u80de\u4e2d\uff0c\u53ef\u4ee5\u4f7f\u7528\u8367\u5149\u6807\u8bb0\u7684\u6297\u4f53\u6216\u62a5\u544a\u57fa\u56e0\u6765\u9a8c\u8bc1sgRNA\u7684\u7f16\u8f91\u6548\u7387\u3002<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u8bba\">\u7ed3\u8bba<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8bbe\u8ba1\u548c\u9a8c\u8bc1\u6709\u6548\u7684sgRNA\u5bf9\u4e8e\u6267\u884c\u51c6\u786e\u9ad8\u6548\u7684CRISPR\u5b9e\u9a8c\u81f3\u5173\u91cd\u8981\u3002\u9075\u5faa\u5efa\u8bae\u7684sgRNA\u8bbe\u8ba1\u6ce8\u610f\u4e8b\u9879\u548c\u9a8c\u8bc1\u6b65\u9aa4\u6709\u52a9\u4e8e\u786e\u4fdd\u521b\u5efa\u51fa\u6709\u6548\u7684sgRNA\u3002\u4e3a\u7b80\u5316sgRNA\u8bbe\u8ba1\uff0c\u8d5b\u9ed8\u98de\u4e16\u5c14\u79d1\u6280\u63d0\u4f9b\u4e86\u4e00\u4e2a\u514d\u8d39\u7684\u5e73\u53f0\uff0c\u7528\u4e8e\u6784\u5efasgRNA\u548c\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u2014\u2014<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/genome-editing\/invitrogen-truedesign-genome-editor.html?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_awa_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">TrueDesign Genome Editor\uff08\u57fa\u56e0\u7ec4\u7f16\u8f91\u5668\uff09<\/a>\u3002\u8fd9\u4e2a\u57fa\u56e0\u7ec4\u7f16\u8f91\u8bbe\u8ba1\u5de5\u5177\u7ed3\u5408\u4e86\u4f18\u5316sgRNA\u8bbe\u8ba1\u6240\u63a8\u8350\u7684\u6ce8\u610f\u4e8b\u9879\uff0c\u5e76\u63d0\u4f9b\u8131\u9776\u8bc4\u4f30\u4e0e\u9a8c\u8bc1\u652f\u6301\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u8f7b\u677e\u7cbe\u51c6\u5730\u6784\u5efasgRNA\u3002\u8bf7\u8bbf\u95ee<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/genome-editing\/invitrogen-truedesign-genome-editor.html?cid=bid_clb_gme_r01_co_pfo1130_pgm1522_col000000_0so_blg_il_awa_og_s00_truedesignblog1\" target=\"_blank\" rel=\"noreferrer noopener\">thermofisher.com\/truedesign\uff08\u8d5b\u9ed8\u98de\u5b98\u7f51\uff09<\/a>\u4e86\u89e3\u66f4\u591a\u4fe1\u606f\u3002\u5982\u9700<a href=\"https:\/\/www.youtube.com\/playlist?list=PLGlvFEwL2wDGe3SQ0vNlmDlvVv7JfgwXx\" target=\"_blank\" rel=\"noreferrer noopener\">\u89c2\u770b\u5982\u4f55\u4f7f\u7528TrueDesign Genome Editor\u7684\u89c6\u9891\u6559\u7a0b<\/a>\uff0c\u8bf7\u5728\u6b64\u6d4f\u89c8\u76f8\u5173\u64ad\u653e\u5217\u8868\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ec5\u4f9b\u79d1\u7814\u4f7f\u7528\u3002\u4e0d\u5f97\u7528\u4e8e\u8bca\u65ad\u7a0b\u5e8f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u6587\u732e\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">[1]&nbsp; DeWeirdt, P. C., et al. (2022). Accounting for small variations in the tracrRNA sequence improves sgRNA activity predictions for CRISPR screening. *Nature Biotechnology, 40*(4), 570-578. <a rel=\"noreferrer noopener\" target=\"_blank\" href=\"https:\/\/doi.org\/10.1038\/s41587-021-01107-5\">https:\/\/doi.org\/10.1038\/s41587-021-01107-5<\/a>&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] Doench, J. G., et al. (2016). Optimized sgRNA design to maximize activity and minimize off-target effects of CRISPR-Cas9. *Nature Biotechnology, 34*(2), 184-191. <a rel=\"noreferrer noopener\" target=\"_blank\" href=\"https:\/\/doi.org\/10.1038\/nbt.3437\">https:\/\/doi.org\/10.1038\/nbt.3437<\/a>&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u8bbe\u8ba1\u6709\u6548\u7684CRISPR\u5b9e\u9a8c\u6d89\u53ca\u591a\u4e2a\u6b65\u9aa4\uff0c\u5176\u4e2d\u4e4b\u4e00\u5c31\u662f\u6709\u6548\u8bbe\u8ba1\u5355\u94fe\u5411\u5bfcRNA\uff08sgRNA\uff09\u3002sgRNA\u662f\u53ef\u7f16\u7a0b\u5e8f<\/p>\n","protected":false},"author":1852,"featured_media":238,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[29],"division":[9],"class_list":["post-237","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-sgrna","division-bid","entry"],"_selected_authors":[744],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7\" \/>\n<meta property=\"og:description\" content=\"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-24T03:04:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-10T06:51:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7\",\"datePublished\":\"2026-02-24T03:04:16+00:00\",\"dateModified\":\"2026-03-10T06:51:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/\"},\"wordCount\":171,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/TrueDesignblogimage_1200x628.png\",\"keywords\":[\"sgRNA\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/\",\"name\":\"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/TrueDesignblogimage_1200x628.png\",\"datePublished\":\"2026-02-24T03:04:16+00:00\",\"dateModified\":\"2026-03-10T06:51:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/TrueDesignblogimage_1200x628.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/TrueDesignblogimage_1200x628.png\",\"width\":1200,\"height\":628},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/tips-to-optimize-sgrna-design\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/","og_locale":"zh_CN","og_type":"article","og_title":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7","og_description":"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-02-24T03:04:16+00:00","article_modified_time":"2026-03-10T06:51:14+00:00","og_image":[{"width":1200,"height":628,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7","datePublished":"2026-02-24T03:04:16+00:00","dateModified":"2026-03-10T06:51:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/"},"wordCount":171,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png","keywords":["sgRNA"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/","name":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png","datePublished":"2026-02-24T03:04:16+00:00","dateModified":"2026-03-10T06:51:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u4e86\u89e3\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u91cd\u8981\u6027\uff0c\u5e76\u53d1\u73b0\u4e00\u6b3e\u80fd\u591f\u7b80\u5316\u7cbe\u786e\u57fa\u56e0\u7f16\u8f91\u5b9e\u9a8c\u6d41\u7a0b\u7684\u5de5\u5177\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628.png","width":1200,"height":628},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/tips-to-optimize-sgrna-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u4f18\u5316sgRNA\u8bbe\u8ba1\u7684\u6280\u5de7"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":29,"label":"sgRNA"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/TrueDesignblogimage_1200x628-1024x536.png",760,398,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":29,"name":"sgRNA","slug":"sgrna","term_group":0,"term_taxonomy_id":29,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=237"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/237\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/238"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=237"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}