{"id":519,"date":"2026-02-27T05:40:20","date_gmt":"2026-02-27T05:40:20","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=519"},"modified":"2026-03-09T05:53:50","modified_gmt":"2026-03-09T05:53:50","slug":"5-major-detection-methods-in-multimode-microplate-readers","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/","title":{"rendered":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/image012.png\" alt=\"A scientist in PPE inserts a 96 well plate into a multimode microplate reader\" class=\"wp-image-4362\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-jetpack-sharing-buttons has-normal-icon-size jetpack-sharing-buttons__services-list\" id=\"jetpack-sharing-serivces-list\">\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"yoast-reading-time__wrapper\"><span class=\"yoast-reading-time__icon\"><svg aria-hidden=\"true\" focusable=\"false\" data-icon=\"clock\" width=\"20\" height=\"20\" fill=\"none\" stroke=\"currentColor\" style=\"display:inline-block;vertical-align:-0.1em\" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\"><path stroke-linecap=\"round\" stroke-linejoin=\"round\" stroke-width=\"2\" d=\"M12 8v4l3 3m6-3a9 9 0 11-18 0 9 9 0 0118 0z\"><\/path><\/svg><\/span><span class=\"yoast-reading-time__spacer\" style=\"display:inline-block;width:1em\"><\/span><span class=\"yoast-reading-time__spacer\" style=\"width:1em\"><\/span><span class=\"yoast-reading-time__descriptive-text\">Estimated reading time: <\/span><span class=\"yoast-reading-time__reading-time\">4<\/span><span class=\"yoast-reading-time__time-unit\"> \u5206\u949f<\/span><\/p>\n\n\n\n<div class=\"wp-block-yoast-seo-table-of-contents yoast-table-of-contents\"><h2>\u76ee\u5f55<\/h2><ul><li><a href=\"#h-\u4ec0\u4e48\u662f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\" data-level=\"2\">\u4ec0\u4e48\u662f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\uff1f<\/a><\/li><li><a href=\"#h-\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e38\u89c1\u7684\u68c0\u6d4b\u6a21\u5f0f\u6709\u54ea\u4e9b\" data-level=\"2\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e38\u89c1\u7684\u68c0\u6d4b\u6a21\u5f0f\u6709\u54ea\u4e9b\uff1f<\/a><ul><li><a href=\"#h-1-\u5149\u5ea6\u6cd5-\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u5b9a\" data-level=\"3\">1. \u5149\u5ea6\u6cd5\uff1a\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u5b9a<\/a><\/li><li><a href=\"#h-2-\u8367\u5149\u6d4b\u5b9a\u6cd5-\u8367\u5149\u5f3a\u5ea6-fret\u548c\u8367\u5149\u504f\u632f\" data-level=\"3\">2. \u8367\u5149\u6d4b\u5b9a\u6cd5\uff1a\u8367\u5149\u5f3a\u5ea6\u3001FRET\u548c\u8367\u5149\u504f\u632f<\/a><\/li><li><a href=\"#h-3-\u65f6\u95f4\u5206\u8fa8\u8367\u5149\u6d4b\u5b9a\u6cd5-trf\u548ctr-fret\" data-level=\"3\">3. \u65f6\u95f4\u5206\u8fa8\u8367\u5149\u6d4b\u5b9a\u6cd5\uff1aTRF\u548cTR-FRET<\/a><\/li><li><a href=\"#h-4-\u53d1\u5149\u6d4b\u5b9a\u6cd5-\u53d1\u5149\u548cbret\" data-level=\"3\">4. \u53d1\u5149\u6d4b\u5b9a\u6cd5\uff1a\u53d1\u5149\u548cBRET<\/a><\/li><li><a href=\"#h-5-alpha\u68c0\u6d4b\u6280\u672f-alphascreen\u548calphalisa\" data-level=\"3\">5. Alpha\u68c0\u6d4b\u6280\u672f\uff1aAlphaScreen\u548cAlphaLISA<\/a><\/li><\/ul><\/li><li><a href=\"#h-\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u68c0\u6d4b\u6a21\u5f0f\u6bd4\u8f83\" data-level=\"2\">\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u68c0\u6d4b\u6a21\u5f0f\u6bd4\u8f83<\/a><\/li><li><a href=\"#h-thermo-scientific\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u9009\u9879\" data-level=\"2\">Thermo Scientific\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u9009\u9879<\/a><\/li><li><a href=\"#h-\u5173\u4e8e\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u66f4\u591a\u5de5\u5177\u4e0e\u8d44\u6e90\" data-level=\"2\">\u5173\u4e8e\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u66f4\u591a\u5de5\u5177\u4e0e\u8d44\u6e90<\/a><\/li><\/ul><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\">\u4ec0\u4e48\u662f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea<\/strong>\u6216\u79f0\u4e3a\u677f\u5f0f\u68c0\u6d4b\u4eea\uff0c\u662f\u4e00\u79cd\u5b9e\u9a8c\u5ba4\u4eea\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u88c5\u5728\u5fae\u5b54\u677f\uff08\u4e5f\u79f0\u4e3a\u5fae\u4e95\u677f\uff09\u4e2d\u7684\u6837\u54c1\u53d1\u751f\u7684\u751f\u7269\u3001\u5316\u5b66\u6216\u7269\u7406\u4e8b\u4ef6\u3002\u8fd9\u4e9b\u8bbe\u5907\u5bf9\u4e8e\u7814\u7a76\u3001\u9ad8\u901a\u91cf\u7b5b\u9009\u3001\u8bca\u65ad\u4ee5\u53ca\u836f\u7269\u53d1\u73b0\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u901a\u8fc7\u591a\u79cd\u68c0\u6d4b\u65b9\u6cd5\u5206\u6790\u6837\u54c1\uff0c\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5438\u5149\u5ea6\uff0c<\/strong>\u6d4b\u91cf\u6837\u54c1\u5728\u7279\u5b9a\u6ce2\u957f\u4e0b\u5438\u6536\u4e86\u591a\u5c11\u5149\u3002<\/li>\n\n\n\n<li><strong>\u8367\u5149\uff0c<\/strong>\u68c0\u6d4b\u8367\u5149\u5206\u5b50\u53d1\u5c04\u7684\u5149\u3002<\/li>\n\n\n\n<li><strong>\u5316\u5b66\u53d1\u5149<\/strong>\uff0c\u6d4b\u91cf\u5316\u5b66\u53cd\u5e94\u4ea7\u751f\u7684\u5149\u3002<\/li>\n\n\n\n<li><strong>\u65f6\u95f4\u5206\u8fa8\u8367\u5149\uff08TRF\uff09<\/strong>\uff0c\u7528\u4e8e\u654f\u611f\u5e94\u7528\u7684\u589e\u5f3a\u578b\u8367\u5149\u68c0\u6d4b\u3002<\/li>\n\n\n\n<li><strong>\u8367\u5149\u504f\u632f\uff08FP\uff09<\/strong>\u7528\u4e8e\u7ed3\u5408\u7814\u7a76\u3002<\/li>\n\n\n\n<li><strong>\u8367\u5149\u5171\u632f\u80fd\u91cf\u8f6c\u79fb\uff08FRET\uff09\uff0c<\/strong>\u68c0\u6d4b\u4e24\u4e2a\u8367\u5149\u5206\u5b50\u4e4b\u95f4\u7684\u80fd\u91cf\u8f6c\u79fb\uff0c\u5e38\u7528\u4e8e\u5206\u5b50\u76f8\u4e92\u4f5c\u7528\u7814\u7a76\u3002<\/li>\n\n\n\n<li><strong>AlphaScreen\/AlphaLISA<\/strong>\u7528\u4e8e\u751f\u5316\u5206\u6790\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u53ef\u80fd\u63d0\u4f9b\u4e00\u79cd\u6216\u591a\u79cd\u68c0\u6d4b\u6a21\u5f0f\u3002\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u4e3b\u8981\u6709\u4e24\u79cd\u7c7b\u578b\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5355\u6a21\u5f0f\u68c0\u6d4b\u4eea<\/strong>(\u4e13\u95e8\u9488\u5bf9\u4e00\u79cd\u68c0\u6d4b\u65b9\u6cd5)<\/li>\n\n\n\n<li><strong>\u591a\u6a21\u5f0f\u68c0\u6d4b\u4eea<\/strong>(\u80fd\u591f\u8fdb\u884c\u591a\u79cd\u68c0\u6d4b\u65b9\u6cd5\uff0c\u4f7f\u5176\u66f4\u5177\u7075\u6d3b\u6027) versatile)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u73b0\u4ee3\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u901a\u5e38\u4e0e\u81ea\u52a8\u5316\u7cfb\u7edf\u96c6\u6210\uff0c\u7528\u4e8e\u9ad8\u901a\u91cf\u7b5b\u9009\u548c\u5b9e\u65f6\u6570\u636e\u5206\u6790\uff0c\u4f7f\u5176\u6210\u4e3a\u5148\u8fdb\u7814\u7a76\u5e94\u7528\u4e2d\u4e0d\u53ef\u6216\u7f3a\u7684\u5de5\u5177\u3002\u5b83\u4eec\u8fd8\u53ef\u80fd<a href=\"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/monochromator-or-filter-based-plate-reader\/\">\u91c7\u7528\u4e0d\u540c\u7684\u5149\u5b66\u673a\u5236\u8fdb\u884c\u5206\u6790<\/a>\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5728\u836f\u7269\u53d1\u73b0\uff08\u5982\u6f5c\u5728\u836f\u7269\u7684\u9ad8\u901a\u91cf\u7b5b\u9009\uff09\u3001\u5206\u5b50\u751f\u7269\u5b66\uff08\u5982DNA\u3001RNA\u548c\u86cb\u767d\u8d28\u5b9a\u91cf\uff09\u3001\u98df\u54c1\u5b89\u5168\u4e0e\u73af\u5883\u76d1\u6d4b\uff08\u5982\u68c0\u6d4b\u6c61\u67d3\u7269\u6216\u6bd2\u7d20\uff09\u7b49\u4f17\u591a\u7814\u7a76\u9886\u57df\u90fd\u975e\u5e38\u6709\u7528\u3002<\/p>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75\"><a class=\"wp-block-button__link has-background has-medium-font-size has-text-align-center has-custom-font-size wp-element-button\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers.html\" style=\"border-radius:0px;background-color:#ee3134\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u4fe1\u606f<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e38\u89c1\u7684\u68c0\u6d4b\u6a21\u5f0f\u6709\u54ea\u4e9b\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e38\u89c1\u7684\u68c0\u6d4b\u6a21\u5f0f\u6709\u54ea\u4e9b\uff1f<\/h2>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-\u5149\u5ea6\u6cd5-\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u5b9a\">1. \u5149\u5ea6\u6cd5\uff1a\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u5b9a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5149\u5ea6\u6d4b\u91cf\u4f7f\u7528<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers.html\">\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea<\/a>\u57fa\u4e8e\u5149\u5b50\u7684\u5149\u53ef\u4ee5\u88ab\u6eb6\u6db2\u4e2d\u7684\u6837\u54c1\u5438\u6536\u6216\u6563\u5c04\u8fd9\u4e00\u539f\u7406\u3002\u5bf9\u5149\u5438\u6536\u7684\u6d4b\u91cf\u7528\u4e8e\u57fa\u4e8e\u5438\u5149\u5ea6\u7684\u5fae\u5b54\u677f\u5206\u6790\uff0c\u800c\u5bf9\u5149\u6563\u5c04\u7684\u6d4b\u91cf\u5219\u7528\u4e8e\u6d4a\u5ea6\u6cd5\u5fae\u5b54\u677f\u5206\u6790\u3002<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/cell-analysis-learning-center\/cell-analysis-resource-library\/cell-analysis-application-notes\/absorbance-turbidimetric-scattering-photometry.html\">\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u91cf<\/a>\u65e2\u7ecf\u6d4e\u5b9e\u60e0\u53c8\u64cd\u4f5c\u7b80\u4fbf\uff0c\u9002\u7528\u4e8e\u5404\u79cd\u7a33\u5065\u7684\u5fae\u5b54\u677f\u68c0\u6d4b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u7684\u5438\u5149\u5ea6\u68c0\u6d4b\u7528\u4e8e\u6d4b\u91cf\u6837\u54c1\u5438\u6536\u7684\u5149\u91cf\u3002\u5f53\u5149\u901a\u8fc7\u6837\u54c1\u65f6\uff0c\u90e8\u5206\u5149\u88ab\u6837\u54c1\u4e2d\u7684\u5206\u5b50\u5438\u6536\uff0c\u4ece\u800c\u51cf\u5c11\u5230\u8fbe\u68c0\u6d4b\u5668\u7684\u5149\u5f3a\u5ea6\u3002\u7531\u4e8e\u5206\u5b50\u5728\u7279\u5b9a\u6ce2\u957f\u4e0b\u5438\u6536\u5149\uff0c\u56e0\u6b64\u53ef\u4ee5\u6839\u636e\u5438\u6536\u7684\u5149\u91cf\u8fdb\u884c\u5b9a\u91cf\u3002\u53ef\u89c1\u5438\u5149\u5ea6\u68c0\u6d4b\u5229\u7528\u67d3\u6599\uff0c\u5728\u53cd\u5e94\u6216\u5206\u5b50\u6d3b\u52a8\u540e\u4ea7\u751f\u989c\u8272\uff0c\u5e76\u53ef\u901a\u8fc7\u6eb6\u6db2\u67d3\u6599\u53d8\u6df1\u65f6\u5438\u5149\u5ea6\u53d8\u5316\u8fdb\u884c\u76d1\u6d4b\u3002\u7d2b\u5916\u5438\u5149\u5ea6\u68c0\u6d4b\u65e0\u9700\u5916\u90e8\u67d3\u6599\uff0c\u57fa\u4e8e\u5bf9\u6837\u54c1\u5185\u5728\u5438\u5149\u5ea6\u7684\u6d4b\u91cf\u3002\u57fa\u4e8e\u5438\u5149\u5ea6\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e38\u89c1\u5e94\u7528\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/dna-rna-purification-analysis\/nucleic-acid-quantitation.html\">\u6838\u9178<\/a>\u548c<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Technical-Notes\/spectrophotometric-determination-protein-concentrations-280nm-technote.pdf\">\u86cb\u767d\u8d28<\/a> 260\/280 nm\u5904\u7684\u5b9a\u91cf\u5206\u6790<\/li>\n\n\n\n<li>\u6bd4\u8272\u6cd5\u86cb\u767d\u8d28\u5b9a\u91cf\u5206\u6790\uff08\u5982<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-assays-analysis\/protein-assays\/bca-protein-assays.html\">BCA\u86cb\u767d\u8d28\u5206\u6790\u6cd5<\/a>\u548c<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-assays-analysis\/protein-assays\/bradford-assays.html\">Bradford\u86cb\u767d\u8d28\u5206\u6790\u6cd5<\/a>)<\/li>\n\n\n\n<li>\u9176\u8054\u514d\u75ab\u5438\u9644\u6d4b\u5b9a\uff08<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-biology-learning-center\/protein-biology-resource-library\/pierce-protein-methods\/overview-elisa.html\">ELISAs<\/a>)<\/li>\n\n\n\n<li>\u7ec6\u80de\u6d3b\u529b\u68c0\u6d4b\uff0c\u901a\u8fc7\u5728\u6d3b\u7ec6\u80de\u4e2d\u4ea7\u751f\u6bd4\u8272\u4fe1\u53f7\uff08\u4f8b\u5982\uff0c<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/X12223\">CyQUANT XTT\u7ec6\u80de\u6d3b\u529b\u68c0\u6d4b<\/a>)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u7684\u6d4a\u5ea6\u68c0\u6d4b\u6d89\u53ca\u6839\u636e\u60ac\u6d6e\u9897\u7c92\u6216\u6eb6\u6db2\u7684\u6df7\u6d4a\u7a0b\u5ea6\u6765\u6d4b\u91cf\u5149\u5b50\u7684\u6563\u5c04\u3002\u6837\u54c1\u4e2d\u9897\u7c92\u6d53\u5ea6\u8d8a\u9ad8\uff0c\u6d4a\u5ea6\u548c\u5149\u6563\u5c04\u5c31\u8d8a\u5927\uff0c\u4ece\u800c\u51cf\u5c11\u7167\u660e\u65f6\u5230\u8fbe\u68c0\u6d4b\u5668\u7684\u5149\u91cf\u3002\u5bfc\u81f4\u5149\u6563\u5c04\u7684\u9897\u7c92\u53ef\u4ee5\u5305\u62ec\u7ec6\u80de\u3001\u805a\u96c6\u4f53\u3001\u6c89\u6dc0\u7269\u6216\u6eb6\u6db2\u4e2d\u5b58\u5728\u7684\u5176\u4ed6\u56fa\u4f53\u3002\u7ec6\u83cc\u751f\u957f\u66f2\u7ebf\u662f\u91c7\u7528\u6d4a\u5ea6\u6d4b\u91cf\u7684\u4e00\u79cd\u5e38\u89c1\u5e94\u7528\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85bbffd&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85bbffd\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/PlateReader01.png\" alt=\"Figure illustrating the concepts of absorbance and turbidimetric detection in multimode microplate readers\" class=\"wp-image-3912\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe1. \u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u7684\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u68c0\u6d4b\u3002\uff08A\uff09\u5728\u5438\u5149\u5ea6\u68c0\u6d4b\u4e2d\uff0c\u6837\u54c1\u5438\u6536\u5149\u7ebf\uff0c\u5bfc\u81f4\u88ab\u5149\u7535\u63a2\u6d4b\u5668\u68c0\u6d4b\u5230\u7684\u5149\u5f3a\u964d\u4f4e\u3002\uff08B\uff09\u5728\u6d4a\u5ea6\u68c0\u6d4b\u4e2d\uff0c\u7531\u4e8e\u6837\u54c1\u4e2d\u7684\u56fa\u4f53\u9897\u7c92\u5f15\u8d77\u7684\u5149\u5b50\u6563\u5c04\uff0c\u5230\u8fbe\u5149\u7535\u63a2\u6d4b\u5668\u7684\u5149\u5f3a\u4e5f\u4f1a\u964d\u4f4e\u3002<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-\u8367\u5149\u6d4b\u5b9a\u6cd5-\u8367\u5149\u5f3a\u5ea6-fret\u548c\u8367\u5149\u504f\u632f\">2. \u8367\u5149\u6d4b\u5b9a\u6cd5\uff1a\u8367\u5149\u5f3a\u5ea6\u3001FRET\u548c\u8367\u5149\u504f\u632f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u7528\u4e8e<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/cell-analysis\/cell-analysis-learning-center\/molecular-probes-school-of-fluorescence\/fluorescence-basics\/fluorescence-fundamentals\/process-fluorescence.html\">\u8367\u5149\u68c0\u6d4b<\/a>\u901a\u8fc7\u6d4b\u91cf\u8367\u5149\u56e2\u5728\u7279\u5b9a\u6ce2\u957f\u6fc0\u53d1\u540e\u53d1\u51fa\u7684\u5149\u6765\u5b9e\u73b0\u3002\u8367\u5149\u56e2\u80fd\u591f\u5728\u67d0\u4e00\u6ce2\u957f\u5438\u6536\u5149\uff0c\u7136\u540e\u4ee5\u66f4\u957f\u6ce2\u957f\u53d1\u51fa\u8367\u5149\uff0c\u53ef\u4ee5\u4e0e\u5176\u4ed6\u5206\u5b50\u7ed3\u5408\u6216\u4f5c\u4e3a\u5206\u5b50\u6d3b\u52a8\u6216\u53cd\u5e94\u7684\u6307\u793a\u5242\u4f7f\u7528\u3002\u8367\u5149\u5206\u5b50\u5177\u6709\u6fc0\u53d1\u548c\u53d1\u5c04\u8c31\uff0c\u4f7f\u5176\u80fd\u901a\u8fc7\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7528\u5176\u6fc0\u53d1\u8c31\u8303\u56f4\u5185\u7684\u706f\u7167\u660e\uff0c\u5e76\u968f\u540e\u68c0\u6d4b\u8f83\u957f\u6ce2\u957f\u7684\u53d1\u5c04\u8fdb\u884c\u5206\u6790\u3002\u8367\u5149\u5f3a\u5ea6\u4e0e\u8367\u5149\u56e2\u6d53\u5ea6\u5448\u7ebf\u6027\u5173\u7cfb\uff0c\u53ef\u7528\u4e8e\u5b9a\u91cf\u6d4b\u91cf\u3002\u4e0e\u5438\u6536\u6cd5\u76f8\u6bd4\uff0c\u8367\u5149\u6cd5\u5177\u6709\u66f4\u9ad8\u7075\u654f\u5ea6\u3001\u66f4\u5bbd\u52a8\u6001\u8303\u56f4\uff0c\u5e76\u80fd\u5b9e\u73b0\u591a\u91cd\u6807\u8bb0\u4e0d\u540c\u8367\u5149\u56e2\u3002\u5e38\u89c1\u5229\u7528\u8367\u5149\u5f3a\u5ea6\u8fdb\u884c\u5206\u6790\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5e94\u7528\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4f7f\u7528\u7ed3\u5408DNA\u548cRNA\u7684\u8367\u5149\u67d3\u6599\u8fdb\u884c\u6838\u9178\u5b9a\u91cf<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/brands\/product-brand\/quant-it.html\">Quant-iT DNA\u548cRNA\u68c0\u6d4b\u8bd5\u5242<\/a>)<\/li>\n\n\n\n<li>\u7528\u6d3b\u7ec6\u80de\u7684\u8fd8\u539f\u73af\u5883\u5c06\u96f7\u624e\u7ea2\u8f6c\u5316\u4e3a\u8367\u5149\u7f57\u4e39\u660e\u7684\u7ec6\u80de\u6d3b\u6027\u548c\u589e\u6b96\u68c0\u6d4b<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/cell-analysis\/fluorescence-microplate-assays\/microplate-assays-cell-viability\/prestoblue-cell-viability-reagent.html\">PrestoBlue<\/a>\u548c<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/fluorescence-microplate-assays\/microplate-assays-cell-viability\/alamarblue-assay-cell-viability.html\">alamarBlue<\/a>\u7ec6\u80de\u6d3b\u6027\u68c0\u6d4b\u8bd5\u5242<\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/fluorescence-microplate-assays\/microplate-assays-ion-indicators.html\">\u9499\u6d41\u68c0\u6d4b<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/references\/gibco-cell-culture-basics\/transfection-basics\/reporter-gene-assays.html\">\u8367\u5149\u62a5\u544a\u57fa\u56e0\u68c0\u6d4b<\/a>(GFP\u3001YFP\u7b49)\u7528\u4e8e\u6d4b\u91cf\u57fa\u56e0\u8868\u8fbe\u548c\u4fe1\u53f7\u901a\u8def\u6fc0\u6d3b<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u8fd8\u7528\u4e8e\u4e00\u4e9b\u7279\u6b8a\u7684\u8367\u5149\u6280\u672f\uff0c\u4f8b\u5982\u8367\u5149\u5171\u632f\u80fd\u91cf\u8f6c\u79fb\uff08FRET\uff09\u548c\u8367\u5149\u504f\u632f\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/references\/molecular-probes-the-handbook\/technical-notes-and-product-highlights\/fluorescence-resonance-energy-transfer-fret.html\">FRET<\/a>\u5b9e\u9a8c\u57fa\u4e8e\u4e24\u79cd\u8367\u5149\u5206\u5b50\uff1a\u4f9b\u4f53\u548c\u53d7\u4f53\u3002\u5f53\u5b83\u4eec\u5f7c\u6b64\u9760\u8fd1\u65f6\uff0c\u80fd\u91cf\u4f1a\u4ece\u4e00\u4e2a\u5206\u5b50\u8f6c\u79fb\u5230\u53e6\u4e00\u4e2a\u5206\u5b50\u3002\u4f9b\u4f53\u5206\u5b50\u5438\u6536\u6fc0\u53d1\u5149\u540e\uff0c\u5e76\u4e0d\u76f4\u63a5\u53d1\u5c04\u5149\uff0c\u800c\u662f\u5c06\u80fd\u91cf\u8f6c\u79fb\u7ed9\u53d7\u4f53\u5206\u5b50\uff0c\u53d7\u4f53\u968f\u540e\u5728\u66f4\u957f\u6ce2\u957f\u5904\u53d1\u5c04\u5149\u3002\u8981\u53d1\u751fFRET\uff0c\u4f9b\u4f53\u7684\u53d1\u5c04\u5149\u8c31\u4e0e\u53d7\u4f53\u7684\u6fc0\u53d1\u5149\u8c31\u5fc5\u987b\u6709\u91cd\u53e0\u3002FRET\u5e38\u7528\u4e8e\u7814\u7a76\u5206\u5b50\u95f4\u76f8\u4e92\u4f5c\u7528\uff0c\u4ee5\u786e\u5b9a\u4e24\u79cd\u5206\u5b50\u662f\u5426\u7ed3\u5408\u6216\u5f7c\u6b64\u63a5\u8fd1\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/references\/molecular-probes-the-handbook\/technical-notes-and-product-highlights\/fluorescence-polarization-fp.html\">\u8367\u5149\u504f\u632f<\/a>\u662f\u53e6\u4e00\u79cd\u8367\u5149\u6280\u672f\uff0c\u5176\u4e2d\u8367\u5149\u56e2\u901a\u8fc7\u504f\u632f\u5149\u88ab\u6fc0\u53d1\uff0c\u7136\u540e\u5229\u7528\u5176\u53d1\u5c04\u51fa\u7684\u504f\u632f\u5149\u6765\u5224\u65ad\u5206\u5b50\u7684\u53d6\u5411\u548c\u6d41\u52a8\u6027\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85bc948&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85bc948\" class=\"aligncenter size-medium wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/PlateReader02-300x248.png\" alt=\"Representation of the FRET spectral overlap integral. \" class=\"wp-image-3917\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe2. FRET \u5149\u8c31\u91cd\u53e0\u79ef\u5206\u793a\u610f\u56fe\u3002\u8981\u53d1\u751fFRET\uff0c\u4f9b\u4f53\u5206\u5b50\u7684\u8367\u5149\u53d1\u5c04\u5149\u8c31\u5fc5\u987b\u4e0e\u53d7\u4f53\u5206\u5b50\u7684\u5438\u6536\u6216\u6fc0\u53d1\u5149\u8c31\u6709\u91cd\u53e0\u533a\u57df\u3002<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-\u65f6\u95f4\u5206\u8fa8\u8367\u5149\u6d4b\u5b9a\u6cd5-trf\u548ctr-fret\">3. \u65f6\u95f4\u5206\u8fa8\u8367\u5149\u6d4b\u5b9a\u6cd5\uff1aTRF\u548cTR-FRET<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u65f6\u95f4\u5206\u8fa8\u8367\u5149\uff08TRF\uff09\u662f\u4e00\u79cd\u7279\u6b8a\u7684\u8367\u5149\u6280\u672f\uff0c\u5b83\u4f7f\u7528\u5177\u6709\u8f83\u957f\u8367\u5149\u5bff\u547d\u7684\u8367\u5149\u56e2\uff0c\u5982\u9567\u7cfb\u87af\u5408\u7269\u6216\u9690\u7a9d\u914d\u5408\u7269\u3002\u8fd9\u4e9b\u5206\u5b50\u7684\u8367\u5149\u53d1\u5c04\u76f8\u6bd4\u6807\u51c6\u8367\u5149\u56e2\u6765\u8bf4\u5ef6\u8fdf\u4e14\u6301\u7eed\u65f6\u95f4\u66f4\u957f\uff0c\u56e0\u6b64\u53ef\u4ee5\u7528\u77ed\u8109\u51b2\u6fc0\u53d1\u540e\uff0c\u5728\u4e00\u6bb5\u65f6\u95f4\u5ef6\u8fdf\u540e\u518d\u8fdb\u884c\u4fe1\u53f7\u68c0\u6d4b\u3002\u7531\u4e8e\u68c0\u6d4b\u662f\u5728\u6fc0\u53d1\u8109\u51b2\u4e4b\u540e\u5ef6\u8fdf\u8fdb\u884c\uff0c\u53ef\u4ee5\u663e\u8457\u51cf\u5c11\u6765\u81ea\u6807\u51c6\u8367\u5149\u56e2\u7684\u80cc\u666f\u548c\u81ea\u53d1\u8367\u5149\uff0c\u63d0\u9ad8\u4fe1\u566a\u6bd4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TRF\u662f\u4e00\u79cd\u5bf9\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u975e\u5e38\u654f\u611f\u7684\u68c0\u6d4b\u6280\u672f\uff0c\u7ecf\u5e38\u7528\u4e8e\u836f\u7269\u7b5b\u9009\u76f8\u5173\u7684\u5fae\u5b54\u677f\u5b9e\u9a8c\u4e2d\u3002\u65f6\u95f4\u5206\u8fa8\u8367\u5149\u5171\u632f\u80fd\u91cf\u8f6c\u79fb\uff08TR-FRET\uff09\u7ed3\u5408\u4e86TRF\u548cFRET\uff0c\u901a\u8fc7\u4f9b\u4f53\u548c\u53d7\u4f53\u4e4b\u95f4\u7684\u80fd\u91cf\u8f6c\u79fb\u5b9e\u73b0\uff0c\u5f53\u4f9b\u4f53\u88ab\u6fc0\u53d1\u540e\uff0c\u5176\u5ef6\u8fdf\u4ea7\u751f\u7684\u8367\u5149\u53ef\u88ab\u68c0\u6d4b\u5230\u3002TR-FRET\u5e38\u7528\u4e8e\u9700\u8981\u9ad8\u7075\u654f\u5ea6\u7684\u5206\u5b50\u76f8\u4e92\u4f5c\u7528\u7814\u7a76\uff0c\u4ee5\u53ca\u86cb\u767d\u8d28\u7ffb\u8bd1\u540e\u4fee\u9970\u5982\u4e0b\u6240\u8ff0\u7b49\u65b9\u9762\u7684\u68c0\u6d4b\uff1a<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/pharma-biopharma\/drug-discovery-development\/target-and-lead-identification-and-validation\/kinasebiology\/kinase-activity-assays\/lanthascreen-tr-fret-toolbox.html\">LanthaScreen \u6fc0\u9176\u6d3b\u6027\u5206\u6790<\/a>\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85bd10b&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85bd10b\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/DetectionModes.jpg\" alt=\"Comparison of different types of fluorometry, including FRET and TRF\" class=\"wp-image-3961\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe3. \u4e0d\u540c\u7c7b\u578b\u7684\u8367\u5149\u6d4b\u5b9a\u6cd5\u5bf9\u6bd4\uff0c\u5305\u62ecFRET\u548cTRF<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:22px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85bd805&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85bd805\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/PlateReader04.png\" alt=\"Principle of TR-FRET in LanthaScreen Kinase Activity Assays\" class=\"wp-image-3918\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe4. LanthaScreen\u6fc0\u9176\u6d3b\u6027\u5206\u6790\u4e2dTR-FRET\u7684\u539f\u7406\u3002(A) \u8367\u5149\u5e95\u7269\u901a\u8fc7\u4e0eATP\u53cd\u5e94\u5728\u6fc0\u9176\u53cd\u5e94\u4e2d\u88ab\u78f7\u9178\u5316\u3002(B) \u968f\u540e\u52a0\u5165\u94fd\u6807\u8bb0\u6297\u4f53\u4ee5\u68c0\u6d4b\u5df2\u78f7\u9178\u5316\u7684\u8367\u5149\u5e95\u7269\u3002(C) \u6297\u4f53\u4e0e\u5df2\u78f7\u9178\u5316\u5e95\u7269\u7ed3\u5408\u540e\uff0c\u589e\u5f3a\u4e86\u94fd\u4f9b\u4f53\u4e0e\u8367\u5149\u53d7\u4f53\u4e4b\u95f4\u7684TR-FRET\u3002\u8fd9\u79cdTR-FRET\u7684\u589e\u52a0\u4e0e\u5df2\u78f7\u9178\u5316\u5e95\u7269\u7684\u91cf\u76f8\u5173\uff0c\u4ece\u800c\u5b9e\u73b0\u5bf9\u6fc0\u9176\u6d3b\u6027\u7684\u6d4b\u91cf\u3002<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-\u53d1\u5149\u6d4b\u5b9a\u6cd5-\u53d1\u5149\u548cbret\">4. \u53d1\u5149\u6d4b\u5b9a\u6cd5\uff1a\u53d1\u5149\u548cBRET<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u7528\u4e8e<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/protein-biology\/protein-biology-learning-center\/protein-biology-resource-library\/pierce-protein-methods\/luciferase-reporters.html\">\u53d1\u5149\u68c0\u6d4b<\/a>\u5176\u4e2d\uff0c\u5149\u662f\u7531\u5316\u5b66\u6216\u751f\u5316\u53cd\u5e94\u4ea7\u751f\u7684\uff0c\u901a\u5e38\u6d89\u53ca\u53d1\u5149\u5e95\u7269\u548c\u9176\u3002\u5177\u6709\u53d1\u5149\u6027\u7684\u5316\u5408\u7269\u5728\u53ef\u89c1\u6ce2\u957f\u8303\u56f4\u5185\u53d1\u5c04\u5149\uff0c\u4e0d\u9700\u8981\u5916\u90e8\u5149\u6e90\u8fdb\u884c\u6fc0\u53d1\u3002\u53d1\u5149\u53ef\u4ee5\u5206\u4e3a\u5316\u5b66\u53d1\u5149\uff0c\u5373\u901a\u8fc7\u542b\u6709\u53d1\u5149\u5206\u5b50\u7684\u5316\u5b66\u53cd\u5e94\uff08\u5982\u9c81\u7c73\u8bfa\uff09\u4ea7\u751f\u7684\u5149\uff1b\u6216\u751f\u7269\u53d1\u5149\uff0c\u5373\u6765\u81ea\u4e8e\u80fd\u81ea\u7136\u4ea7\u751f\u8367\u5149\u751f\u7269\u5206\u5b50\u7684\u751f\u7269\u4f53\uff08\u5982\u8424\u706b\u866b\u4e2d\u7684\u8367\u5149\u7d20\u9176\uff09\u7684\u81ea\u7136\u53d1\u4eae\u73b0\u8c61\u3002 <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u5fae\u5b54\u677f\u5206\u6790\u6765\u8bf4\uff0c\u53d1\u5149\u6cd5\u5177\u6709\u6700\u9ad8\u7075\u654f\u5ea6\u548c\u4f4e\u80cc\u666f\u4fe1\u53f7\u3002\u95ea\u70c1\u578b\u53d1\u5149\u5206\u6790\u4f1a\u4ea7\u751f\u77ed\u6682\u4f46\u5f3a\u70c8\u7684\u77ac\u65f6\u53d1\u5c04\uff0c\u800c\u8f89\u5149\u578b\u53d1\u5149\u5206\u6790\u5219\u80fd\u6301\u7eed\u8f83\u957f\u65f6\u95f4\u3001\u4f46\u5f3a\u5ea6\u8f83\u4f4e\u4e14\u66f4\u7a33\u5b9a\u5730\u91ca\u653e\u51fa\u53ef\u68c0\u6d4b\u4fe1\u53f7\u3002\u57fa\u4e8e\u53d1\u5149\u7684\u5fae\u5b54\u677f\u5206\u6790\u5e38\u7528\u4e8e\u9ad8\u901a\u91cf\u7b5b\u9009\uff08HTS\uff09\u5e94\u7528\uff0c\u56e0\u4e3a\u5176\u7075\u654f\u5ea6\u9ad8\u4e14\u64cd\u4f5c\u7b80\u5355\u3002\u5e38\u89c1\u7684\u57fa\u4e8e\u53d1\u5149\u7684\u5fae\u5b54\u677f\u68c0\u6d4b\u5e94\u7528\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u57fa\u4e8eATP\u6d4b\u5b9a\u7ec6\u80de\u6d3b\u529b\u7684\u65b9\u6cd5\uff0c\u8fd9\u7c7b\u65b9\u6cd5\u4f9d\u8d56\u4e8eATP\u4f5c\u4e3a\u8367\u5149\u7d20\u9176\u4ea7\u751f\u6d3b\u6027\u7684\u5fc5\u9700\u6210\u5206\uff08\u5982CellTiter-Glo\u53ca<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A22066\">ATP\u68c0\u6d4b\u8bd5\u5242\u76d2<\/a>)<\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/protein-biology\/protein-assays-analysis\/reporter-gene-assays.html\">\u57fa\u4e8e\u53d1\u5149\u6cd5\u7684\u62a5\u544a\u57fa\u56e0\u5206\u6790<\/a>\u7528\u4e8e\u6d4b\u91cf\u57fa\u56e0\u8868\u8fbe\u548c\u4fe1\u53f7\u901a\u8def\u6fc0\u6d3b<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u751f\u7269\u53d1\u5149\u5171\u632f\u80fd\u91cf\u8f6c\u79fb\uff08BRET\uff09\u662f\u4e00\u79cd\u4e0eFRET\u7c7b\u4f3c\u7684\u6280\u672f\uff0c\u4f46\u5b83\u6d89\u53ca\u4ece\u53d1\u5149\u4f9b\u4f53\u5411\u8367\u5149\u53d7\u4f53\u8f6c\u79fb\u53d1\u5c04\u7684\u5149\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85be0aa&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85be0aa\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/PlateReader05.png\" alt=\"Comparison of bioluminescence and fluorescence\" class=\"wp-image-3919\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe5. \u751f\u7269\u53d1\u5149\u4e0e\u8367\u5149\u7684\u6bd4\u8f83\u3002(A) \u751f\u7269\u53d1\u5149\u662f\u6307\u9176\uff08\u5982\u8424\u706b\u866b\u8367\u5149\u7d20\u9176\uff09\u4e0e\u5176\u5e95\u7269\u8367\u5149\u7d20\u53cd\u5e94\u65f6\u4ea7\u751f\u7684\u5149\u3002\u8f85\u52a9\u56e0\u5b50\u9700\u6c42\uff0c\u5982ATP\u6216O2\u4f1a\u6839\u636e\u6240\u4f7f\u7528\u7684\u8367\u5149\u7d20\u9176\u800c\u6709\u6240\u4e0d\u540c\u3002(B) \u8367\u5149\u662f\u6307\u8367\u5149\u56e2\uff08\u5982FITC\u6216Alexa Fluor\u67d3\u6599\uff09\u5438\u6536\u6765\u81ea\u6fc0\u53d1\u5149\u6e90\u7684\u80fd\u91cf\uff0c\u5e76\u5728\u4e0d\u540c\u6ce2\u957f\u4e0b\u53d1\u5c04\u51fa\u5149\u3002<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-alpha\u68c0\u6d4b\u6280\u672f-alphascreen\u548calphalisa\">5. Alpha\u68c0\u6d4b\u6280\u672f\uff1aAlphaScreen\u548cAlphaLISA<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Alpha\u68c0\u6d4b\u6280\u672f\u662f\u4e00\u79cd\u57fa\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u5668\u7684\u73e0\u7c92\u7ed3\u5408\u5206\u6790\u65b9\u6cd5\uff0c\u5229\u7528\u4f9b\u4f53\u73e0\u548c\u53d7\u4f53\u73e0\u5728\u63a5\u8fd1\u65f6\u4ea7\u751f\u53d1\u5149\u4fe1\u53f7\u3002\u4f9b\u4f53\u73e0\u5728680 nm\u7ea2\u8272\u6fc0\u53d1\u4e0b\u4ea7\u751f\u5355\u6001\u6c27\uff0c\u5355\u6001\u6c27\u968f\u540e\u6269\u6563\u5230\u53d7\u4f53\u73e0\uff0c\u4ea7\u751f520-620 nm\u8303\u56f4\u5185\u7684\u53d1\u5c04\uff0c\u88ab\u677f\u8bfb\u4eea\u68c0\u6d4b\u3002\u53ef\u4ee5\u5c06\u5206\u5b50\u8fde\u63a5\u5230\u73e0\u7c92\u4e0a\uff0c\u4f7f\u4f9b\u4f53\u548c\u53d7\u4f53\u73e0\u5728\u7ed3\u5408\u65f6\u9760\u8fd1\uff0c\u4ece\u800c\u542f\u52a8\u5355\u6001\u6c27\u4ece\u4f9b\u4f53\u5230\u53d7\u4f53\u7684\u8f6c\u79fb\u3002\u5728AlphaScreen\u5fae\u5b54\u677f\u5206\u6790\u4e2d\u4f7f\u7528\u7684\u53d7\u4f53\u73e0\u53ef\u5728520-620 nm\u8303\u56f4\u5185\u53d1\u5c04\u5bbd\u8c31\u5149\uff0c\u800cAlphaLISA\u53d7\u4f53\u73e0\u5219\u5177\u6709\u66f4\u7a84\u4e14\u66f4\u4eae\u7684\u53d1\u5c04\u8c31\uff0c\u4f7f\u5176\u9002\u7528\u4e8e\u590d\u6742\u4e14\u5bcc\u542b\u86cb\u767d\u8d28\u6837\u54c1\uff08\u5982\u8840\u6e05\u6216\u8840\u6d46\uff09\u7684\u5fae\u5b54\u677f\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728Alpha\u68c0\u6d4b\u5206\u6790\u4e2d\uff0c\u6fc0\u53d1\u6ce2\u957f\u9ad8\u4e8e\u53d1\u5c04\u6ce2\u957f\uff0c\u6bd4TRF\u66f4\u6709\u6548\u5730\u6d88\u9664\u80cc\u666f\u8367\u5149\u548c\u81ea\u53d1\u8367\u5149\u3002\u4e0eTR-FRET\u548cBRET\u7b49\u5176\u4ed6\u63a5\u8fd1\u6027\u5206\u6790\u76f8\u6bd4\uff0cAlpha\u68c0\u6d4b\u5206\u6790\u4e5f\u66f4\u5bb9\u6613\u8bbe\u7f6e\u548c\u8bbe\u8ba1\uff0c\u65e0\u9700\u590d\u6742\u4f18\u5316\u3002\u7531\u4e8eAlpha\u68c0\u6d4b\u5206\u6790\u4e3a\u5747\u76f8\uff0c\u4e0d\u9700\u8981\u5728\u68c0\u6d4b\u524d\u5206\u79bb\u6216\u6e05\u6d17\u7ed3\u5408\u4e0e\u672a\u7ed3\u5408\u5206\u5b50\uff0c\u56e0\u6b64\u5e38\u7528\u4e8e\u9ad8\u901a\u91cf\u7b5b\u9009\uff08HTS\uff09\u53ca\u836f\u7269\u53d1\u73b0\u5fae\u5b54\u677f\u8bfb\u6570\u5e94\u7528\u3002\u5176\u4ed6\u5e38\u89c1\u5e94\u7528\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u86cb\u767d\u8d28-\u86cb\u767d\u8d28\u76f8\u4e92\u4f5c\u7528\u7814\u7a76<\/li>\n\n\n\n<li>\u751f\u7269\u6807\u5fd7\u7269\u68c0\u6d4b<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004b85be901&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004b85be901\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/Bead-diagram.jpg\" alt=\"Principle of AlphaScreen and AlphaLISA assays\" class=\"wp-image-3960\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><em><em>\u56fe6. AlphaScreen \u548c AlphaLISA \u5206\u6790\u539f\u7406\u3002(A) \u5728 AlphaScreen \u5206\u6790\u4e2d\uff0c\u4f9b\u4f53\u73e0\u8fde\u63a5\u5230\u5206\u5b50A\uff0c\u53d7\u4f53\u73e0\u8fde\u63a5\u5230\u5206\u5b50B\u3002\u5f53\u5206\u5b50A\u548cB\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\u65f6\uff0c\u4f9b\u4f53\u548c\u53d7\u4f53\u73e0\u9760\u8fd1\u3002\u5bf9\u4f9b\u4f53\u73e0\u8fdb\u884c680 nm\u6fc0\u53d1\u540e\u751f\u6210\u5355\u6001\u6c27\uff0c\u8be5\u5355\u6001\u6c27\u6269\u6563\u81f3\u53d7\u4f53\u73e0\u5e76\u4ea7\u751f520-620 nm\u8303\u56f4\u5185\u7684\u53d1\u5c04\u3002(B) AlphaLISA \u5206\u6790\u4f7f\u7528\u6bd4 AlphaScreen \u53d7\u4f53\u73e0\u5177\u6709\u66f4\u7a84\u4e14\u66f4\u4eae\u7684\u53d1\u5c04\u8c31\u7684\u53d7\u4f53\u73e0\u3002<\/em><\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:21px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u68c0\u6d4b\u6a21\u5f0f\u6bd4\u8f83\">\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u68c0\u6d4b\u6a21\u5f0f\u6bd4\u8f83<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-regular\" style=\"font-size:14px\"><table class=\"has-white-background-color has-background has-fixed-layout\"><thead><tr><th><strong>\u68c0\u6d4b\u6a21\u5f0f<\/strong><\/th><th><strong><strong>\u539f\u7406<\/strong><\/strong><\/th><th><strong><strong>\u4f18\u52bf\u4e0e\u7279\u70b9<\/strong><\/strong><\/th><th><strong><strong>\u5e38\u89c1\u68c0\u6d4b\u65b9\u6cd5\u53ca\u5e94\u7528<\/strong><\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>\u5438\u5149\u5ea6<\/strong><\/td><td>\u6d4b\u91cf\u6837\u54c1\u5438\u6536\u7684\u5149\u7684\u6570\u91cf<\/td><td>\u2022\u6210\u672c\u6548\u76ca\u9ad8<br>\u2022\u68c0\u6d4b\u65b9\u6cd5\u7a33\u5b9a\u53ef\u9760<\/td><td>\u2022\u86cb\u767d\u8d28\u5b9a\u91cf<br>\u2022\u6838\u9178\u5b9a\u91cf<br>\u2022\u7ec6\u80de\u6d3b\u6027<br>\u2022\u9176\u8054\u514d\u75ab\u5438\u9644\u6d4b\u5b9a\uff08ELISA\uff09<\/td><\/tr><tr><td><strong>\u6d4a\u5ea6\u6cd5<\/strong><\/td><td>\u6d4b\u91cf\u6837\u54c1\u7684\u5149\u6563\u5c04<\/td><td>\u2022\u6210\u672c\u6548\u76ca\u9ad8<br>\u2022\u68c0\u6d4b\u65b9\u6cd5\u7a33\u5b9a\u53ef\u9760<\/td><td>\u7ec6\u83cc\u751f\u957f\u66f2\u7ebf<\/td><\/tr><tr><td><strong>\u8367\u5149\u6cd5<\/strong><\/td><td>\u6d4b\u91cf\u8367\u5149\u6837\u54c1\u5728\u6fc0\u53d1\u4e0b\u7684\u53d1\u5c04<\/td><td>\u2022\u9ad8\u7075\u654f\u5ea6<br>\u2022\u5bbd\u52a8\u6001\u8303\u56f4<br>\u2022\u591a\u91cd\u68c0\u6d4b<\/td><td>\u2022\u6838\u9178\u5b9a\u91cf<br>\u2022\u7ec6\u80de\u6d3b\u6027<br>\u2022\u9499\u6d41\u52a8\u5206\u6790<br>\u2022\u62a5\u544a\u57fa\u56e0\u5206\u6790\uff08\u5982GFP\uff0cYFP\uff09<\/td><\/tr><tr><td><strong>\u53d1\u5149<\/strong><\/td><td>\u6d4b\u91cf\u5316\u5b66\u6216\u751f\u5316\u53cd\u5e94\u4e2d\u4ea7\u751f\u7684\u5149<\/td><td>\u2022\u6700\u9ad8\u7075\u654f\u5ea6<br>\u2022\u4e0d\u9700\u8981\u6fc0\u53d1\u5149<\/td><td>\u2022\u7ec6\u80de\u6d3b\u6027\/ATP\u68c0\u6d4b<br>\u2022\u62a5\u544a\u57fa\u56e0\u5206\u6790<br>\u2022\u9ad8\u901a\u91cf\u7b5b\u9009<\/td><\/tr><tr><td><strong>\u65f6\u95f4\u5206\u8fa8\u8367\u5149<\/strong><\/td><td>\u6d4b\u91cf\u5177\u6709\u957f\u8367\u5149\u5bff\u547d\u5206\u5b50\u7684\u5ef6\u8fdf\u8367\u5149\u53d1\u5c04<\/td><td>\u2022\u9ad8\u7075\u654f\u5ea6<br>\u2022\u65f6\u95f4\u5ef6\u8fdf\u53ef\u51cf\u5c11\u8367\u5149\u80cc\u666f<\/td><td>\u2022\u76f8\u4e92\u4f5c\u7528\u7814\u7a76<br>\u2022\u86cb\u767d\u8d28\u7ffb\u8bd1\u540e\u4fee\u9970\u7814\u7a76<br>\u2022\u836f\u7269\u53d1\u73b0<\/td><\/tr><tr><td><strong>Alpha \u68c0\u6d4b<\/strong><\/td><td>\u5f53\u5fae\u7403\u9760\u8fd1\u65f6\u6d4b\u91cf\u5149\u53d1\u5c04<\/td><td>\u2022\u5747\u76f8\u68c0\u6d4b<br>\u2022\u65e0\u9700\u6d17\u6da4\u6b65\u9aa4<br>\u2022\u6fc0\u53d1\u6ce2\u957f\u9ad8\u4e8e\u53d1\u5c04\u6ce2\u957f\uff0c\u53ef\u6d88\u9664\u8367\u5149\u80cc\u666f<\/td><td>\u2022\u9ad8\u901a\u91cf\u7b5b\u9009<br>\u2022\u836f\u7269\u53d1\u73b0<br>\u2022\u76f8\u4e92\u4f5c\u7528\u7814\u7a76<br>\u2022\u751f\u7269\u6807\u5fd7\u7269\u68c0\u6d4b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-thermo-scientific\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u9009\u9879\">Thermo Scientific\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u9009\u9879<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8d5b\u9ed8\u98de\u79d1\u5b66\u516c\u53f8\u63d0\u4f9b\u91c7\u7528\u591a\u79cd\u68c0\u6d4b\u6a21\u5f0f\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-fc.html\"><strong>Multiskan FC \u5fae\u5b54\u677f\u5149\u5ea6\u8ba1<\/strong><\/a>\u548c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-skyhigh.html\"><strong>Multiskan SkyHigh \u5fae\u5b54\u677f\u5206\u5149\u5149\u5ea6\u8ba1<\/strong><\/a>\u90fd\u80fd\u591f\u8fdb\u884c\u5438\u5149\u5ea6\u548c\u6d4a\u5ea6\u6d4b\u5b9a\uff0c\u800c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan-alf.html\"><strong>Varioskan ALF<\/strong><\/a> \u548c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan.html\"><strong>Varioskan LUX<\/strong><\/a> \u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u7528\u4e8e\u5305\u62ec\u5438\u5149\u5ea6\u3001\u6d4a\u5ea6\u3001\u8367\u5149\u548c\u53d1\u5149\u5728\u5185\u7684\u591a\u79cd\u68c0\u6d4b\u6a21\u5f0f\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan.html\"><strong>Varioskan LUX<\/strong><\/a>\u662f\u4e00\u6b3e\u5148\u8fdb\u7684\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\uff0c\u540c\u65f6\u517c\u5bb9\u4e13\u95e8\u6280\u672f\u5982\u65f6\u95f4\u5206\u8fa8\u8367\u5149\u548cAlphaScreen\/AlphaLISA\u68c0\u6d4b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u901a\u8fc7\u6ee4\u5149\u7247\u6216\u5355\u8272\u4eea\u6765\u9694\u79bb\u7279\u5b9a\u6ce2\u957f\u7684\u5149\uff0c\u7528\u4e8e\u4e0d\u540c\u68c0\u6d4b\u6a21\u5f0f\u4e0b\u7684\u7167\u660e\u548c\u68c0\u6d4b\u3002\u6ee4\u5149\u7247\u5141\u8bb8\u4e00\u5b9a\u5e26\u5bbd\u7684\u5149\u901a\u8fc7\u6837\u54c1\uff0c\u800c\u5355\u8272\u4eea\u5219\u5c06\u5149\u5206\u79bb\u4e3a\u7279\u5b9a\u6ce2\u957f\u7528\u4e8e\u6837\u54c1\u7167\u660e\u548c\u68c0\u6d4b\u3002\u9605\u8bfb\u535a\u5ba2\u201c<a href=\"https:\/\/www.thermofisher.com\/blog\/life-in-the-lab\/monochromator-or-filter-based-plate-reader\/\"><strong>\u9009\u62e9\u5355\u8272\u4eea\u8fd8\u662f\u6ee4\u5149\u7247\u578b\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\uff1f\u5982\u4f55\u51b3\u7b56<\/strong><\/a>\u201d\u4ee5\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u5355\u8272\u4eea\u548c\u6ee4\u5149\u7247\u578b\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u4f18\u52bf\u4e0e\u7528\u9014\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th><b>\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u578b\u53f7<\/b><\/th><th><b>\u68c0\u6d4b\u6a21\u5f0f<\/b><\/th><\/tr><\/thead><tbody><tr><td><img decoding=\"async\" src=\"\/blog\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/P01.png\" alt=\"Multiskan FC plate reader\" align=\"center\"><br><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-fc.html\"><strong>Multiskan FC\uff08\u591a\u529f\u80fdFC\uff09<\/strong><\/a><\/td><td>\u5438\u6536\u3001\u6d4a\u5ea6\u6d4b\u91cf<\/td><\/tr><tr><td><img decoding=\"async\" src=\"\/blog\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/P02.png\" alt=\"Multiskan SkyHigh plate reader\" align=\"center\"><br><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-skyhigh.html\"><strong>Multiskan SkyHigh<\/strong><\/a><\/td><td>\u5438\u6536\u3001\u6d4a\u5ea6\u6d4b\u91cf<\/td><\/tr><tr><td><img decoding=\"async\" src=\"\/blog\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/P03.png\" alt=\"Varioskan ALF plate reader\" align=\"center\"><br><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan-alf.html\"><strong>Varioskan ALF<\/strong><\/a><\/td><td>\u5438\u5149\u5ea6\uff0c\u6d4a\u5ea6\u6d4b\u5b9a\uff0c\u8367\u5149\uff0c\u53d1\u5149<\/td><\/tr><tr><td><img decoding=\"async\" src=\"\/blog\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/02\/P04.png\" alt=\"Varioskan LUX plate reader\" align=\"center\"><br><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan.html\"><strong>Varioskan LUX<\/strong><\/a><\/td><td>\u5438\u5149\u5ea6\uff0c\u6d4a\u5ea6\u6d4b\u5b9a\uff0c\u8367\u5149\u3002\n<br>\u53ef\u9009\uff1a\u65f6\u95f4\u5206\u8fa8\u8367\u5149\uff08TRF\uff09\u3001\u53d1\u5149\u3001AlphaScreen\/AlphaLISA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75\"><a class=\"wp-block-button__link has-background has-medium-font-size has-text-align-center has-custom-font-size wp-element-button\" href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers.html\" style=\"border-radius:0px;background-color:#ee3134\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u4fe1\u606f<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5173\u4e8e\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u66f4\u591a\u5de5\u5177\u4e0e\u8d44\u6e90\">\u5173\u4e8e\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u7684\u66f4\u591a\u5de5\u5177\u4e0e\u8d44\u6e90<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u67e5\u770b\u6211\u4eec\u7684<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/brochures\/guide-microplate-readers.pdf\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u6307\u5357<\/a><\/li>\n\n\n\n<li>\u9009\u62e9<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models.html\">\u8d5b\u9ed8\u98de\u79d1\u5b66\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u578b\u53f7<\/a> <\/li>\n\n\n\n<li>\u6309\u9700\u89c2\u770b\uff1a<a href=\"https:\/\/www.labroots.com\/ms\/webinar\/elevate-research-strategies-effective-microplate-reader-utilization\">\u9ad8\u6548\u5229\u7528\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u7b56\u7565<\/a> <\/li>\n\n\n\n<li>\u6d4f\u89c8\u6211\u4eec\u7684<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Reference-Materials\/microplate-instruments-assays-accessories-guide.pdf\">\u5fae\u5b54\u677f\u4eea\u5668\u3001\u8bd5\u5242\u76d2\u548c\u914d\u4ef6\u6307\u5357<\/a><\/li>\n\n\n\n<li>\u63a2\u7d22\u6211\u4eec\u7684<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/assays.html\">\u5fae\u5b54\u677f\u68c0\u6d4b\u65b9\u6cd5<\/a>\u548c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/cell-analysis\/fluorescence-microplate-assays.html\">\u8367\u5149\u5fae\u5b54\u677f\u68c0\u6d4b\u65b9\u6cd5<\/a> <\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">##<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u00a9 2025 Thermo Fisher Scientific Inc. \u4fdd\u7559\u6240\u6709\u6743\u5229\u3002\u9664\u975e\u53e6\u6709\u8bf4\u660e\uff0c\u6240\u6709\u5546\u6807\u5747\u4e3a Thermo Fisher Scientific \u53ca\u5176\u5b50\u516c\u53f8\u7684\u8d22\u4ea7\u3002<\/em>&nbsp;<em>\u5982\u6709\u8bf4\u660e\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><em>\u4ec5\u4f9b\u79d1\u7814\u4f7f\u7528\u3002\u4e0d\u5f97\u7528\u4e8e\u8bca\u65ad\u7a0b\u5e8f\u3002<\/em><\/em><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u4ec0\u4e48\u662f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\uff1f \u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u6216\u79f0\u4e3a\u677f\u5f0f\u68c0\u6d4b\u4eea\uff0c\u662f\u4e00\u79cd\u5b9e\u9a8c\u5ba4\u4eea\u5668\uff0c\u7528\u4e8e\u68c0\u6d4b\u88c5\u5728\u5fae\u5b54\u677f\uff08\u4e5f\u79f0\u4e3a\u5fae\u4e95\u677f\uff09\u4e2d\u7684\u6837<\/p>\n","protected":false},"author":1852,"featured_media":520,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[41,40],"division":[9],"class_list":["post-519","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-41","tag-40","division-bid","entry"],"_selected_authors":[744],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-27T05:40:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-09T05:53:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png\" \/>\n\t<meta property=\"og:image:width\" content=\"935\" \/>\n\t<meta property=\"og:image:height\" content=\"496\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5\",\"datePublished\":\"2026-02-27T05:40:20+00:00\",\"dateModified\":\"2026-03-09T05:53:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/\"},\"wordCount\":150,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/image012.png\",\"keywords\":[\"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\",\"\u9176\u6807\u4eea\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#respond\"]}],\"accessibilityFeature\":[\"tableOfContents\"]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/\",\"name\":\"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/image012.png\",\"datePublished\":\"2026-02-27T05:40:20+00:00\",\"dateModified\":\"2026-03-09T05:53:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/image012.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/image012.png\",\"width\":935,\"height\":496},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/5-major-detection-methods-in-multimode-microplate-readers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/","og_locale":"zh_CN","og_type":"article","og_title":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5","og_description":"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-02-27T05:40:20+00:00","article_modified_time":"2026-03-09T05:53:50+00:00","og_image":[{"width":935,"height":496,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5","datePublished":"2026-02-27T05:40:20+00:00","dateModified":"2026-03-09T05:53:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/"},"wordCount":150,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png","keywords":["\u5fae\u5b54\u677f\u8bfb\u6570\u4eea","\u9176\u6807\u4eea"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#respond"]}],"accessibilityFeature":["tableOfContents"]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/","name":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png","datePublished":"2026-02-27T05:40:20+00:00","dateModified":"2026-03-09T05:53:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u672c\u6307\u5357\u4ecb\u7ecd\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea(\u9176\u6807\u4eea)\u7684\u4e94\u79cd\u4e3b\u8981\u68c0\u6d4b\u6a21\u5f0f\uff0c\u5305\u62ec\u8367\u5149\u3001\u53d1\u5149\u3001\u5438\u5149\u5ea6\u7b49\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png","width":935,"height":496},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/5-major-detection-methods-in-multimode-microplate-readers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u591a\u6a21\u5f0f\u9176\u6807\u4eea\u4e2d\u76845\u79cd\u68c0\u6d4b\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":41,"label":"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea"},{"value":40,"label":"\u9176\u6807\u4eea"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/image012.png",760,403,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea","slug":"%e5%be%ae%e5%ad%94%e6%9d%bf%e8%af%bb%e6%95%b0%e4%bb%aa","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":40,"name":"\u9176\u6807\u4eea","slug":"%e9%85%b6%e6%a0%87%e4%bb%aa","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/519","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=519"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/519\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/520"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=519"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=519"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=519"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=519"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}