{"id":558,"date":"2026-02-27T05:57:13","date_gmt":"2026-02-27T05:57:13","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=558"},"modified":"2026-03-09T05:53:00","modified_gmt":"2026-03-09T05:53:00","slug":"monochromator-or-filter-based-plate-reader","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/","title":{"rendered":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Plate-Reader-Image-1024x668.jpg\" alt=\"Choosing a Plate Reader: Monochromator or Filter-based? \" class=\"wp-image-3687\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u80fd\u591f\u5feb\u901f\u5206\u6790\u591a\u5b54\u677f\u4e0a\u7684\u6837\u54c1\uff0c\u901a\u8fc7\u91cf\u5316\u8367\u5149\u3001\u5438\u5149\u5ea6\u3001\u53d1\u5149\u548c\u6d4a\u5ea6\u7b49\u5173\u952e\u4fe1\u53f7\u3002\u7136\u800c\uff0c\u5e76\u975e\u6240\u6709\u7684\u677f\u8bfb\u6570\u4eea\u90fd\u5177\u5907\u76f8\u540c\u7684\u529f\u80fd\uff0c\u56e0\u6b64\u4e86\u89e3\u5b9e\u9a8c\u5ba4\u9700\u6c42\u4e0e\u73b0\u6709\u6280\u672f\u7684\u7ed3\u5408\u70b9\u975e\u5e38\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u4eba\u5458\u5728\u8d2d\u4e70\u65f6\u6700\u5e38\u89c1\u7684\u95ee\u9898\u4e4b\u4e00\u662f\u9009\u62e9\u5355\u8272\u5668\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u6307\u5357\u5c06\u8be6\u7ec6\u89e3\u6790\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u80cc\u540e\u7684\u5149\u5b66\u673a\u5236\uff0c\u4ecb\u7ecd\u6bcf\u79cd\u9009\u9879\u7684\u4f18\u7f3a\u70b9\uff0c\u4ee5\u53ca\u4e3a\u4f55\u60a8\u53ef\u80fd\u4f1a\u9009\u62e9\u5176\u4e2d\u4e00\u79cd\u800c\u4e0d\u662f\u53e6\u4e00\u79cd\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662f\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247-\u5b83\u4eec\u5728\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5982\u4f55\u4f7f\u7528\">\u4ec0\u4e48\u662f\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\uff0c\u5b83\u4eec\u5728\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5982\u4f55\u4f7f\u7528\uff1f\n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u901a\u8fc7\u9009\u62e9\u6027\u5730\u53d1\u5c04\u6216\u68c0\u6d4b\u7279\u5b9a\u8303\u56f4\u7684\u5149\u6765\u5de5\u4f5c\u3002\u4e3a\u4e86\u9009\u62e9\u5206\u6790\u6240\u9700\u7684\u76f8\u5173\u6ce2\u957f\uff0c\u76ee\u524d\u7684\u677f\u8bfb\u6570\u4eea\u91c7\u7528\u5355\u8272\u5668\u6216\u5149\u5b66\u6ee4\u5149\u7247\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5355\u8272\u5668\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\">\u5355\u8272\u5668\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5355\u8272\u5668\uff08\u5176\u540d\u79f0\u6e90\u81ea\u5e0c\u814a\u8bed\u201c\u5355\u4e00\u989c\u8272\u201d\uff09\u662f\u4e00\u79cd\u53ef\u4ee5\u673a\u68b0\u5730\u4ece\u4e00\u675f\u5149\u4e2d\u5206\u79bb\u51fa\u7279\u5b9a\u6ce2\u957f\u7684\u8bbe\u5907\u3002\u542b\u6709\u5355\u8272\u5668\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u4ee5\u8bbe\u7f6e\u4e3a\u5728\u5176\u8303\u56f4\u5185\u4efb\u610f\u7279\u5b9a\u6ce2\u957f\u8fdb\u884c\u6837\u54c1\u7684\u5438\u6536\u548c\u53d1\u5c04\u6d4b\u91cf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u677f\u8bfb\u6570\u4eea\u4e2d\u7684\u5355\u8272\u5668\u901a\u8fc7\u5c06\u5149\u6563\u5c04\u5230\u884d\u5c04\u5149\u6805\u4e0a\uff0c\u5e76\u5229\u7528\u4e00\u7cfb\u5217\u955c\u5b50\u7cbe\u786e\u5730\u5c06\u4eea\u5668\u7684\u5149\u6e90\u5206\u79bb\u6210\u4e0d\u540c\u989c\u8272\u6210\u5206\u6765\u5de5\u4f5c\u3002\u968f\u540e\uff0c\u5355\u8272\u5668\u53ea\u5141\u8bb8\u9009\u5b9a\u6ce2\u957f\u7684\u5149\u901a\u8fc7\u5e76\u7167\u5c04\u5230\u6837\u54c1\u4e0a\u3002\u4ece\u6837\u54c1\u8fd4\u56de\u7cfb\u7edf\u540e\uff0c\u7ecf\u8fc7\u9009\u62e9\u6027\u7684\u884d\u5c04\u5149\u6805\u548c\u955c\u5b50\uff0c\u518d\u6b21\u53ea\u6709\u4e00\u4e2a\u6ce2\u957f\u5230\u8fbe\u68c0\u6d4b\u5668\u8fdb\u884c\u4fe1\u53f7\u8bfb\u53d6\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\">\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ee4\u5149\u7247\u662f\u4e00\u79cd\u5149\u5b66\u88c5\u7f6e\uff0c\u53ea\u5141\u8bb8\u7279\u5b9a\u6ce2\u957f\u7684\u5149\u901a\u8fc7\u3002\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u9176\u6807\u4eea\u65e2\u6709\u6fc0\u53d1\u6ee4\u5149\u7247\uff08\u7528\u4e8e\u8fc7\u6ee4\u4ece\u4eea\u5668\u5230\u6837\u54c1\u7684\u5149\uff09\uff0c\u4e5f\u6709\u53d1\u5c04\u6ee4\u5149\u7247\uff08\u7528\u4e8e\u8fc7\u6ee4\u4ece\u6837\u54c1\u5230\u68c0\u6d4b\u5668\u7684\u5149\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ee4\u5149\u7247\u80fd\u591f\u900f\u8fc7\u7684\u6ce2\u957f\u8303\u56f4\u88ab\u79f0\u4e3a\u6ee4\u5149\u7247\u7684\u5e26\u5bbd\u3002\u8d85\u51fa\u6ee4\u5149\u7247\u5e26\u5bbd\u8303\u56f4\u7684\u5149\u65e0\u6cd5\u901a\u8fc7\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Plate-Reader-Combined-Infographic.jpg\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Plate-Reader-Combined-Infographic.jpg\" alt=\"Figure 1. Diagrams of the optics in filter-based and monochromator-based plate readers\" class=\"wp-image-3701\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>\u56fe1. \u57fa\u4e8e\u6ee4\u5149\u7247\u548c\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u9176\u6807\u4eea\u4e2d\u5149\u5b66\u7cfb\u7edf\u793a\u610f\u56fe\u3002<\/strong>(A) \u5728\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u9176\u6807\u4eea\u4e2d\uff0c\u6765\u81ea\u4eea\u5668\u5149\u6e90\u7684\u5149\u901a\u8fc7\u5305\u542b\u884d\u5c04\u5149\u6805\u548c\u4e00\u7cfb\u5217\u53cd\u5c04\u955c\u7684\u6fc0\u53d1\u5355\u8272\u4eea\u8fdb\u884c\u6269\u6563\uff0c\u4ee5\u5206\u79bb\u51fa\u7528\u4e8e\u7167\u5c04\u6837\u54c1\u7684\u5355\u4e00\u6ce2\u957f\u3002\u6765\u81ea\u6837\u54c1\u7684\u53d1\u5c04\u5149\u518d\u901a\u8fc7\u53d1\u5c04\u5355\u8272\u4eea\u6269\u6563\uff0c\u786e\u4fdd\u53ea\u6709\u7279\u5b9a\u6ce2\u957f\u5230\u8fbe\u68c0\u6d4b\u5668\u3002(B) \u5728\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u9176\u6807\u4eea\u4e2d\uff0c\u6765\u81ea\u4eea\u5668\u5149\u6e90\u7684\u5149\u5148\u7ecf\u8fc7\u6fc0\u53d1\u6ee4\u5149\u7247\uff0c\u4ec5\u5141\u8bb8\u67d0\u4e00\u6ce2\u957f\u8303\u56f4\u7167\u4eae\u6837\u54c1\u3002\u968f\u540e\uff0c\u6765\u81ea\u6837\u54c1\u7684\u53d1\u5c04\u5149\u518d\u7ecf\u8fc7\u53d1\u5c04\u6ee4\u5149\u7247\uff0c\u786e\u4fdd\u53ea\u6709\u7279\u5b9a\u6ce2\u957f\u8303\u56f4\u5230\u8fbe\u68c0\u6d4b\u5668\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u57fa\u4e8e\u6ee4\u5149\u7247\u548c\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u9176\u6807\u4eea\u6709\u4ec0\u4e48\u533a\u522b-\u54ea\u79cd\u66f4\u597d-nbsp\">\u57fa\u4e8e\u6ee4\u5149\u7247\u548c\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u9176\u6807\u4eea\u6709\u4ec0\u4e48\u533a\u522b\uff1f\u54ea\u79cd\u66f4\u597d\uff1f<strong style=\"font-family: 'Helvetica Neue', 'Segoe UI', Helvetica, Arial, 'Lucida Grande', sans-serif;font-size: 13px\">&nbsp;<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u9176\u6807\u4eea\u6765\u8bf4\uff0c\u6ca1\u6709\u552f\u4e00\u201c\u6b63\u786e\u201d\u7684\u9009\u62e9\uff0c\u6700\u4f73\u9009\u62e9\u53d6\u51b3\u4e8e\u60a8\u5b9e\u9a8c\u5ba4\u7684\u9700\u6c42\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u6765\u8bf4\uff0c\u914d\u5907\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u7075\u6d3b\u9009\u62e9\u4efb\u610f\u6ce2\u957f\uff0c\u975e\u5e38\u9002\u5408\u8fdb\u884c\u591a\u79cd\u7c7b\u578b\u5b9e\u9a8c\u6216\u5168\u8c31\u626b\u63cf\u3002\u800c\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5219\u662f\u6267\u884c\u5e38\u89c4\u5b9e\u9a8c\u65f6\u7ecf\u6d4e\u4e14\u53ef\u9760\u7684\u9009\u62e9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u57fa\u4e8e\u5355\u8272\u4eea\u4e0e\u57fa\u4e8e\u6ee4\u5149\u7247\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e3b\u8981\u4f18\u52bf\u53ca\u7528\u9014\u603b\u7ed3\">\u57fa\u4e8e\u5355\u8272\u4eea\u4e0e\u57fa\u4e8e\u6ee4\u5149\u7247\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e3b\u8981\u4f18\u52bf\u53ca\u7528\u9014\u603b\u7ed3<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Second-Table.jpg\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Second-Table.jpg\" alt=\"Key benefits and uses of monochromator-based vs. filter-based microplate readers\" class=\"wp-image-3704\" \/><\/a><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u57fa\u4e8e\u5355\u8272\u4eea\u9176\u6807\u4eea\u4f18\u70b9\"><strong>\u57fa\u4e8e\u5355\u8272\u4eea\u9176\u6807\u4eea\u4f18\u70b9<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u66f4\u9ad8\u7075\u6d3b\u6027<\/strong>\u2014\u5355\u8272\u4eea\u80fd\u591f\u5728\u4eea\u5668\u8303\u56f4\u5185\u9009\u62e9\u4efb\u610f\u6ce2\u957f\u7684\u5149\uff0c\u65e0\u9700\u66f4\u6362\u7269\u7406\u6ee4\u5149\u7247\u3002\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u65e0\u9700\u8fdb\u884c\u786c\u4ef6\u66f4\u6362\u6216\u5347\u7ea7\u5373\u53ef\u8fd0\u884c\u65b0\u7684\u68c0\u6d4b\u65b9\u6cd5\u6216\u68c0\u6d4b\u5177\u6709\u4e0d\u540c\u5149\u8c31\u7684\u8367\u5149\u56e2\u3002\u8fd9\u79cd\u53ef\u8c03\u8282\u7684\u6ce2\u957f\u9009\u62e9\u4e3a\u9700\u8981\u4e0d\u540c\u68c0\u6d4b\u6ce2\u957f\u3001\u8fdb\u884c\u591a\u6837\u5316\u5b9e\u9a8c\u548c\u5206\u6790\u7684\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u4e86\u7075\u6d3b\u6027\u3002\u4f7f\u7528\u5355\u8272\u4eea\uff0c\u5b9e\u9a8c\u5ba4\u65e0\u9700\u4e3a\u5206\u6790\u4e0d\u540c\u8367\u5149\u56e2\u548c\u68c0\u6d4b\u65b9\u6cd5\u800c\u8d2d\u4e70\u989d\u5916\u6ee4\u5149\u7247\uff0c\u4f7f\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u8bbe\u5907\u66f4\u80fd\u9002\u5e94\u672a\u6765\u5b9e\u9a8c\u5ba4\u7684\u53d1\u5c55\u9700\u6c42\u3002<\/li>\n\n\n\n<li><strong>\u7cbe\u786e\u6ce2\u957f\u9009\u62e9<\/strong>\u2014\u5355\u8272\u4eea\u80fd\u591f\u5bf9\u6ce2\u957f\u8fdb\u884c\u7cbe\u7ec6\u8c03\u8282\uff0c\u4ee5\u6ee1\u8db3\u7279\u5b9a\u67d3\u6599\u6216\u5b9e\u9a8c\u7684\u9700\u6c42\uff0c\u8fd9\u5bf9\u4e8e\u5f00\u53d1\u81ea\u5b9a\u4e49\u68c0\u6d4b\u65b9\u6cd5\u548c\u4f18\u5316\u68c0\u6d4b\u6027\u80fd\u81f3\u5173\u91cd\u8981\u3002\u5f53\u5904\u7406\u5177\u6709\u975e\u6807\u51c6\u5149\u8c31\u7279\u6027\u7684\u8367\u5149\u56e2\uff08\u5982\u6fc0\u53d1\u5cf0\u4e0e\u53d1\u5c04\u5cf0\u63a5\u8fd1\u6216Stokes\u4f4d\u79fb\u8f83\u5c0f\uff0c\u4f8b\u5982GFP\u53ca\u5176\u4ed6\u8367\u5149\u86cb\u767d\uff0c\u89c1\u56fe2\uff09\u65f6\uff0c\u8fd9\u4e00\u529f\u80fd\u5c24\u4e3a\u6709\u76ca\u3002<\/li>\n\n\n\n<li><strong>\u5168\u8c31\u626b\u63cf<\/strong>\u2014\u5355\u8272\u4eea\u53ef\u4ee5\u626b\u63cf\u4eea\u5668\u8303\u56f4\u5185\u6240\u6709\u6ce2\u957f\uff0c\u5b9e\u73b0\u5bf9\u6574\u4e2a\u5438\u6536\u6216\u8367\u5149\u5149\u8c31\u7684\u8bfb\u53d6\u3002\u5f53\u672a\u77e5\u5b8c\u6574\u5149\u8c31\uff0c\u6216\u8005\u5728\u5b58\u5728\u5149\u8c31\u6f02\u79fb\u7684\u68c0\u6d4b\u4e2d\uff0c\u9700\u8981\u8868\u5f81\u548c\u786e\u5b9a\u67d0\u4e00\u68c0\u6d4b\u65b9\u6cd5\u6216\u8367\u5149\u56e2\u7684\u5438\u6536\u4e0e\u53d1\u5c04\u5cf0\u65f6\uff0c\u9891\u8c31\u626b\u63cf\u975e\u5e38\u6709\u7528\u3002<\/li>\n\n\n\n<li><strong>\u964d\u4f4e\u9891\u8c31\u4e32\u6270<\/strong>\u2014\u7531\u4e8e\u80fd\u591f\u68c0\u6d4b\u6240\u6709\u6ce2\u957f\u4e14\u6d4b\u91cf\u5e26\u5bbd\u8f83\u7a84\uff0c\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u4ee5\u5728\u76f8\u8fd1\u6ce2\u957f\u4e4b\u95f4\u5b9e\u73b0\u66f4\u597d\u7684\u9891\u8c31\u5206\u8fa8\u7387\uff0c\u4ece\u800c\u51cf\u5c11\u4e32\u6270\uff0c\u5e76\u63d0\u5347\u5bf9\u5177\u6709\u91cd\u53e0\u5149\u8c31\u7684\u5206\u6790\u65b9\u6cd5\u548c\u67d3\u6599\u7684\u7075\u654f\u5ea6\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u57fa\u4e8e\u5355\u8272\u4eea\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u4e0d\u5229\u56e0\u7d20\"><strong>\u57fa\u4e8e\u5355\u8272\u4eea\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u4e0d\u5229\u56e0\u7d20<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6210\u672c\u4e0e\u7ef4\u62a4\u589e\u52a0<\/strong>\u2014\u5728\u57fa\u4e8e\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\uff0c\u4e3a\u5b9e\u73b0\u6ce2\u957f\u9009\u62e9\u6240\u9700\u8c03\u6574\u884d\u5c04\u5149\u6805\u7684\u4f4d\u7f6e\u4ee5\u53ca\u53cd\u5c04\u955c\u79fb\u52a8\uff0c\u9700\u8981\u66f4\u590d\u6742\u7684\u673a\u68b0\u7ed3\u6784\uff0c\u8fd9\u4f1a\u589e\u52a0\u6210\u672c\uff0c\u5e76\u53ef\u80fd\u4f7f\u8fd9\u4e9b\u8bfb\u6570\u8bbe\u5907\u66f4\u96be\u7ef4\u62a4\u3002\u6b64\u5916\uff0c\u5355\u8272\u4eea\u8fd8\u9700\u8981\u66f4\u5f3a\u5927\u7684\u5149\u6e90\uff0c\u8fd9\u4e5f\u4f1a\u589e\u52a0\u5176\u8d39\u7528\u3002<\/li>\n\n\n\n<li><strong>\u5bf9\u53d1\u5149\u548c\u65f6\u95f4\u5206\u8fa8\u8367\u5149\u7684\u7075\u654f\u5ea6\u8f83\u4f4e<\/strong>\u2014\u4f7f\u7528\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5728\u68c0\u6d4b\u5149\u53d1\u5c04\u65b9\u9762\u6548\u7387\u4e0d\u9ad8\uff0c\u56e0\u6b64\u5e76\u4e0d\u9002\u7528\u4e8e\u53d1\u5149\u548c\u65f6\u95f4\u5206\u8fa8\u8367\u5149\uff08TRF\uff09\u5b9e\u9a8c\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u7684\u4f18\u70b9\"><strong>\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u7684\u4f18\u70b9<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6210\u672c\u8f83\u4f4e<\/strong>\u2014\u7531\u4e8e\u6ee4\u5149\u7247\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u6d3b\u52a8\u90e8\u4ef6\u8f83\u5c11\uff0c\u5b83\u4eec\u4ef7\u683c\u66f4\u4f4e\uff0c\u7ef4\u62a4\u9700\u6c42\u4e5f\u6bd4\u5e26\u6709\u5355\u8272\u4eea\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5c11\u3002\u6ee4\u5149\u7247\u8fd8\u80fd\u66f4\u9ad8\u6548\u5730\u4f20\u9012\u5149\u7ebf\uff0c\u5e76\u4e14\u4e0d\u9700\u8981\u5f3a\u5927\u7684\u5149\u6e90\uff0c\u8fd9\u8fdb\u4e00\u6b65\u964d\u4f4e\u4e86\u6210\u672c\u3002<\/li>\n\n\n\n<li><strong>\u975e\u5e38\u9002\u5408\u5e38\u89c4\u5b9e\u9a8c<\/strong>\u2014\u5bf9\u4e8e\u4f7f\u7528\u6807\u51c6\u67d3\u6599\u548c\u8367\u5149\u56e2\u8fdb\u884c\u5e38\u89c4\u5b9e\u9a8c\u7684\u5ba2\u6237\u6765\u8bf4\uff0c\u6ee4\u5149\u7247\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u662f\u4e00\u79cd\u7ecf\u6d4e\u5b9e\u7528\u4e14\u7b80\u5355\u7684\u9009\u62e9\u3002<\/li>\n\n\n\n<li><strong>\u5728\u67d0\u4e9b\u5e94\u7528\u4e2d\u5177\u6709\u66f4\u9ad8\u7075\u654f\u5ea6<\/strong>\u2014\u6ee4\u5149\u7247\u5141\u8bb8\u7279\u5b9a\u6ce2\u957f\u8303\u56f4\u6216\u5e26\u5bbd\u7684\u5149\u901a\u8fc7\uff0c\u56e0\u6b64\u6bd4\u5355\u8272\u4eea\u66f4\u6709\u6548\u5730\u4f20\u9012\u5149\u7ebf\uff0c\u800c\u5355\u8272\u4eea\u53ea\u80fd\u5c06\u4e00\u90e8\u5206\u5149\u4f20\u9012\u5230\u6837\u54c1\u53ca\u5176\u8fd4\u56de\u3002\u8fd9\u79cd\u6ee4\u5149\u7247\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u5728\u4f20\u9012\u5149\u7ebf\u4e0a\u7684\u6548\u7387\u63d0\u5347\u4e86\u7075\u654f\u5ea6\uff0c\u4f7f\u5f97\u5728\u53d1\u5149\u548cTRF\u5b9e\u9a8c\u4e2d\u68c0\u6d4b\u9650\u66f4\u4f4e\u3002\u5bf9\u4e8e\u9700\u8981\u8f83\u5927\u5e26\u5bbd\u4ee5\u5b9e\u73b0\u9ad8\u7075\u654f\u5ea6\u7684\u5b9e\u9a8c\uff0c\u5982AlphaScreen\u5b9e\u9a8c\uff0c\u5fc5\u987b\u91c7\u7528\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u7684\u7f3a\u70b9\"><strong>\u6ee4\u5149\u7247\u578b\u677f\u8bfb\u6570\u4eea\u7684\u7f3a\u70b9<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7075\u6d3b\u6027\u8f83\u4f4e<\/strong>\u2014\u6ee4\u5149\u7247\u5177\u6709\u56fa\u5b9a\u7684\u6ce2\u957f\u8303\u56f4\uff0c\u56e0\u6b64\u6240\u9009\u6ee4\u5149\u7247\u5fc5\u987b\u4e0e\u8367\u5149\u56e2\u6216\u5b9e\u9a8c\u7684\u6ce2\u957f\u8981\u6c42\u76f8\u5339\u914d\u3002\u8fd9\u9650\u5236\u4e86\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u9176\u6807\u4eea\u5728\u8fd0\u884c\u4e0d\u7b26\u5408\u73b0\u6709\u6ee4\u5149\u7247\u6ce2\u957f\u8303\u56f4\u7684\u5b9e\u9a8c\u65f6\u7684\u7075\u6d3b\u6027\u3002\u5728\u8fd9\u79cd\u60c5\u51b5\u4e0b\uff0c\u5b9e\u9a8c\u5ba4\u53ef\u80fd\u9700\u8981\u91c7\u8d2d\u65b0\u7684\u6ee4\u5149\u7247\u3002<\/li>\n\n\n\n<li><strong>\u65e0\u6cd5\u8fdb\u884c\u5149\u8c31\u626b\u63cf<\/strong>\u2014\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u65e0\u6cd5\u7528\u4e8e\u5bf9\u65b0\u578b\u67d3\u6599\u8fdb\u884c\u5168\u5149\u8c31\u626b\u63cf\uff0c\u4ee5\u786e\u5b9a\u5176\u5438\u6536\u548c\u53d1\u5c04\u5149\u8c31\u53ca\u5cf0\u503c\uff0c\u4e5f\u65e0\u6cd5\u5bf9\u65b0\u5f00\u53d1\u7684\u5b9e\u9a8c\u8fdb\u884c\u8868\u5f81\u3002<\/li>\n\n\n\n<li><strong>\u8f83\u4f4e\u7684\u5149\u8c31\u5206\u8fa8\u7387<\/strong>\u2014\u6ee4\u5149\u7247\u5177\u6709\u76f8\u5bf9\u8f83\u5bbd\u7684\u6ce2\u957f\u8303\u56f4\uff0c\u5e76\u5141\u8bb8\u8f83\u5bbd\u8303\u56f4\u7684\u5149\u901a\u8fc7\u3002\u8fd9\u4f7f\u5f97\u96be\u4ee5\u533a\u5206\u5904\u4e8e\u540c\u4e00\u6ee4\u5149\u7247\u5e26\u5bbd\u5185\u4e0d\u540c\u6ce2\u957f\u7684\u4fe1\u53f7\u3002\u7531\u4e8e\u5176\u6ce2\u957f\u8303\u56f4\u8f83\u5bbd\uff0c\u6ee4\u5149\u7247\u5728\u533a\u5206\u5177\u6709\u63a5\u8fd1\u53d1\u5c04\/\u6fc0\u53d1\u8c31\u91cd\u53e0\u6216Stokes\u4f4d\u79fb\u8f83\u5c0f\uff08\u6fc0\u53d1\u4e0e\u53d1\u5c04\u5cf0\u503c\u8ddd\u79bb\u5c0f\uff09\u7684\u8367\u5149\u56e2\u65b9\u9762\uff0c\u4e0d\u5982\u5355\u8272\u5668\u6709\u6548\u3002\u5355\u8272\u5668\u53ef\u4ee5\u901a\u8fc7\u9009\u62e9\u6027\u5730\u9694\u79bb\u7a84\u5e26\u7279\u5b9a\u6ce2\u957f\u6765\u5b9e\u73b0\u7cbe\u7ec6\u8c03\u8282\uff0c\u4ece\u800c\u7528\u4e8e\u7167\u660e\u548c\u68c0\u6d4b\uff08\u89c1\u56fe2\uff09\u3002<\/li>\n\n\n\n<li><strong>\u9002\u5e94\u6027\u8f83\u5dee<\/strong>\u2014\u91c7\u7528\u57fa\u4e8e\u6ee4\u5149\u7247\u68c0\u6d4b\u65b9\u5f0f\u7684\u5fae\u5b54\u677f\u68c0\u6d4b\u4eea\u5bf9\u4e8e\u672a\u6765\u5b9e\u9a8c\u5ba4\u9700\u6c42\u9002\u5e94\u6027\u8f83\u5dee\uff0c\u56e0\u4e3a\u82e5\u8981\u8fd0\u884c\u4e0d\u540c\u6ce2\u957f\u8981\u6c42\u7684\u65b0\u5b9e\u9a8c\uff0c\u53ef\u80fd\u9700\u8981\u8d2d\u4e70\u65b0\u7684\u6ee4\u5149\u7247\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Picture5-e1734390455603.png\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Picture5-e1734390455603.png\" alt=\"Figure 2. Comparison of fitting of double monochromator and filter optics onto fluorophore spectra. \" class=\"wp-image-3697\" \/><\/a><figcaption class=\"wp-element-caption\"><strong>\u56fe2. \u53cc\u5355\u8272\u5668\u4e0e\u6ee4\u5149\u7247\u7cfb\u7edf\u5728\u8367\u5149\u56e2\u8c31\u4e0a\u7684\u62df\u5408\u6bd4\u8f83\u3002<\/strong>(A) \u53cc\u5355\u8272\u5668\u7cfb\u7edf\u5177\u6709\u4e09\u89d2\u5f62\u900f\u8fc7\u7387\u66f2\u7ebf\uff0c\u5728\u5cf0\u503c\u4f20\u8f93\u6ce2\u957f\u524d\u540e\u659c\u7387\u975e\u5e38\u9661\u5ced\u3002\u8fd9\u4f7f\u5f97\u6fc0\u53d1\u548c\u53d1\u5c04\u6d4b\u91cf\u6240\u9700\u8bbe\u7f6e\u7684\u6ce2\u957f\u53ef\u4ee5\u975e\u5e38\u63a5\u8fd1\u8367\u5149\u56e2\u5cf0\u503c\uff0c\u5373\u4f7f\u662fStokes\u4f4d\u79fb\u5f88\u5c0f\uff08\u6fc0\u53d1\u4e0e\u53d1\u5c04\u5cf0\u8ddd\u5f88\u8fd1\uff09\u7684\u8367\u5149\u56e2\u4e5f\u80fd\u5b9e\u73b0\u3002(B) \u6ee4\u5149\u7247\u901a\u5e38\u5177\u6709\u949f\u5f62\u900f\u8fc7\u7387\u66f2\u7ebf\uff0c\u5728\u4f4e\u900f\u8fc7\u533a\u57df\u76f8\u5bf9\u8f83\u5bbd\u3002\u56e0\u6b64\uff0c\u4e0e\u53cc\u5355\u8272\u5668\u76f8\u6bd4\uff0c\u6fc0\u53d1\u548c\u53d1\u5c04\u7528\u6ee4\u5149\u7247\u4e4b\u95f4\u9700\u8981\u66f4\u5927\u7684\u95f4\u9694\u3002\u8fd9\u5e38\u5e38\u5bfc\u81f4\u96be\u4ee5\u5728\u8367\u5149\u56e2\u5cf0\u503c\u5904\u8fdb\u884c\u6700\u4f73\u6fc0\u53d1\u548c\u68c0\u6d4b\uff0c\u56e0\u4e3a\u5fc5\u987b\u5c06\u6fc0\u53d1\u6216\u53d1\u5c04\u6ee4\u955c\uff08\u6216\u4e24\u8005\uff09\u9009\u62e9\u5728\u8367\u5149\u56e2\u5cf0\u503c\u4e4b\u5916\uff0c\u4ece\u800c\u5bfc\u81f4\u4e9a\u6700\u4f73\u6fc0\u53d1\u6216\u4fe1\u53f7\u68c0\u6d4b\u6548\u679c\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-thermo-scientific-\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u9009\u9879\">Thermo Scientific \u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u9009\u9879<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\nThermo Scientific \u63d0\u4f9b\u5177\u6709\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u4e24\u79cd\u6ce2\u957f\u9009\u62e9\u529f\u80fd\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u3002\u5bf9\u4e8e\u9002\u7528\u4e8e\u5438\u5149\u5ea6\u6d4b\u5b9a\u7684\u677f\u5f0f\u8bfb\u6570\u4eea\uff0c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-fc.html\"><strong>Multiskan FC \u5fae\u5b54\u677f\u5149\u5ea6\u8ba1<\/strong><\/a>\u901a\u8fc7\u6ee4\u5149\u7247\u9009\u62e9\u6ce2\u957f\u8fdb\u884c\u5438\u5149\u5ea6\u6d4b\u91cf\uff0c\u800c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/multiskan-skyhigh.html\"><strong>Multiskan SkyHigh \u5fae\u5b54\u677f\u5206\u5149\u5149\u5ea6\u8ba1<\/strong><\/a>\u662f\u4e00\u6b3e\u4f7f\u7528\u5355\u8272\u5668\u8fdb\u884c\u6ce2\u957f\u9009\u62e9\u7684\u7d2b\u5916\/\u53ef\u89c1\u5fae\u5b54\u677f\u5206\u5149\u5149\u5ea6\u8ba1\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan-alf.html\"><strong>Varioskan ALF<\/strong><\/a> \u548c <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan.html\"><strong>Varioskan LUX<\/strong><\/a>\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u6839\u636e\u6240\u7528\u68c0\u6d4b\u6280\u672f\uff0c\u53ef\u91c7\u7528\u6ee4\u5149\u7247\u6216\u5355\u8272\u5668\u4e3a\u57fa\u7840\u7684\u5149\u5b66\u7cfb\u7edf\u8fdb\u884c\u6ce2\u957f\u9009\u62e9\u3002\n\n<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Second-Table-v2-1.jpg\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2024\/12\/Second-Table-v2-1.jpg\" alt=\"Table of detection modes by plate reader model\" class=\"wp-image-3708\" \/><\/a><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5bfb\u627e\u6700\u9002\u5408\u60a8\u7684\u5b9e\u9a8c\u5ba4\u7684-thermo-scientific-\u5fae\u5b54\u677f\u8bfb\u6570\u4eea-\u6839\u636e\u5b9e\u9a8c\u5ba4\u9700\u6c42-\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u80fd\u5df2\u7ecf\u8db3\u591f-\u6216\u8005\u5e26\u6709\u5355\u8272\u5668\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u80fd\u662f\u6700\u4f73\u9009\u62e9-\u6df7\u5408\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea-\u5982\">\u00bb \u5bfb\u627e\u6700\u9002\u5408\u60a8\u7684\u5b9e\u9a8c\u5ba4\u7684<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers.html\">Thermo Scientific \u5fae\u5b54\u677f\u8bfb\u6570\u4eea<\/a>\u6839\u636e\u5b9e\u9a8c\u5ba4\u9700\u6c42\uff0c\u57fa\u4e8e\u6ee4\u5149\u7247\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u80fd\u5df2\u7ecf\u8db3\u591f\uff0c\u6216\u8005\u5e26\u6709\u5355\u8272\u5668\u7684\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u53ef\u80fd\u662f\u6700\u4f73\u9009\u62e9\u3002\u6df7\u5408\u578b\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\uff0c\u5982<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\n\u591a\u6a21\u5f0f\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\uff0c\u91c7\u7528\u6ee4\u5149\u7247\u548c\u5355\u8272\u5668\u8fdb\u884c\u6ce2\u957f\u9009\u62e9\uff0c\u4e3a\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u53e6\u4e00\u79cd\u9009\u62e9\u2014\u2014\u67d0\u4e9b\u68c0\u6d4b\u6216\u5e94\u7528\u53ef\u4f7f\u7528\u6ee4\u5149\u7247\u68c0\u6d4b\uff0c\u5176\u4ed6\u5219\u53ef\u7528\u5355\u8272\u5668\u68c0\u6d4b\u3002<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan-alf.html\"><strong>Varioskan ALF<\/strong><\/a> \u548c <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models\/varioskan.html\"><strong>Varioskan LUX<\/strong><\/a> \u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u4fe1\u606f\n<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u60f3\u9605\u8bfb\u66f4\u591a\u7c7b\u4f3c\u6587\u7ae0\u5417\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers.html\">\u60f3\u9605\u8bfb\u66f4\u591a\u7c7b\u4f3c\u6587\u7ae0\u5417\uff1f<\/a>\u00bb<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u60f3\u9605\u8bfb\u66f4\u591a\u7c7b\u4f3c\u7684\u6587\u7ae0\u5417\uff1f<\/em><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/connect-to-science-digital-care-package.html?icid=bid_cbu_sbu_r01_co_cp1605_pjt12448_blg54883_0so_blg_il_awa_og_s00_C2SDigitalCarPkg\"><em>\u8ba2\u9605\u79d1\u5b66\u8fde\u63a5<\/em><\/a><em>\u3002<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u66f4\u591a\u5173\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u5de5\u5177\u548c\u8d44\u6e90\">\u66f4\u591a\u5173\u4e8e\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u5de5\u5177\u548c\u8d44\u6e90<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u67e5\u770b\u6211\u4eec\u7684<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/brochures\/guide-microplate-readers.pdf\">\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u6307\u5357<\/a><\/li>\n\n\n\n<li>\u9009\u62e9<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/models.html\">\u8d5b\u9ed8\u98de\u79d1\u5b66\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u578b\u53f7<\/a><\/li>\n\n\n\n<li>\u6309\u9700\u89c2\u770b<a href=\"https:\/\/www.labroots.com\/ms\/webinar\/elevate-research-strategies-effective-microplate-reader-utilization\">\u63d0\u5347\u60a8\u7684\u7814\u7a76\uff1a\u6709\u6548\u5229\u7528\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u7684\u7b56\u7565<\/a><\/li>\n\n\n\n<li>\u6d4f\u89c8\u6211\u4eec\u7684<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Reference-Materials\/microplate-instruments-assays-accessories-guide.pdf\">\u5fae\u5b54\u677f\u4eea\u5668\u3001\u8bd5\u5242\u76d2\u53ca\u914d\u4ef6\u6307\u5357<\/a><\/li>\n\n\n\n<li>\u63a2\u7d22\u6211\u4eec\u7684<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/lab-equipment\/microplate-instruments\/plate-readers\/assays.html\">\u5fae\u5b54\u677f\u5206\u6790<\/a>\u548c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/cell-analysis\/fluorescence-microplate-assays.html\">\u8367\u5149\u5fae\u5b54\u677f\u5206\u6790<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\n##\n\n<em>\u00a9 2024 Thermo Fisher Scientific Inc. \u4fdd\u7559\u6240\u6709\u6743\u5229\u3002\u9664\u975e\u53e6\u6709\u8bf4\u660e\uff0c\u6240\u6709\u5546\u6807\u5747\u4e3a Thermo Fisher Scientific \u53ca\u5176\u5b50\u516c\u53f8\u7684\u8d22\u4ea7\u3002 \u6307\u5b9a\u3002<\/em><em>specified.<\/em><br><br><em>\u4ec5\u4f9b\u79d1\u7814\u4f7f\u7528\u3002\u4e0d\u5f97\u7528\u4e8e\u8bca\u65ad\u7a0b\u5e8f\u3002<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u80fd\u591f\u5feb\u901f\u5206\u6790\u591a\u5b54\u677f\u4e0a\u7684\u6837\u54c1\uff0c\u901a\u8fc7\u91cf\u5316\u8367\u5149\u3001\u5438\u5149\u5ea6\u3001\u53d1\u5149\u548c\u6d4a\u5ea6\u7b49\u5173\u952e\u4fe1\u53f7\u3002\u7136\u800c\uff0c\u5e76\u975e\u6240\u6709\u7684\u677f\u8bfb\u6570\u4eea\u90fd<\/p>\n","protected":false},"author":1852,"featured_media":559,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[41,40],"division":[9],"class_list":["post-558","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-41","tag-40","division-bid","entry"],"_selected_authors":[744],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-27T05:57:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-09T05:53:00+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"979\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f\",\"datePublished\":\"2026-02-27T05:57:13+00:00\",\"dateModified\":\"2026-03-09T05:53:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/\"},\"wordCount\":38,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/Plate-Reader-Image.jpg\",\"keywords\":[\"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\",\"\u9176\u6807\u4eea\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/\",\"name\":\"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/Plate-Reader-Image.jpg\",\"datePublished\":\"2026-02-27T05:57:13+00:00\",\"dateModified\":\"2026-03-09T05:53:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/Plate-Reader-Image.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/Plate-Reader-Image.jpg\",\"width\":1500,\"height\":979},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/monochromator-or-filter-based-plate-reader\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/","og_locale":"zh_CN","og_type":"article","og_title":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f","og_description":"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-02-27T05:57:13+00:00","article_modified_time":"2026-03-09T05:53:00+00:00","og_image":[{"width":1500,"height":979,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f","datePublished":"2026-02-27T05:57:13+00:00","dateModified":"2026-03-09T05:53:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/"},"wordCount":38,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg","keywords":["\u5fae\u5b54\u677f\u8bfb\u6570\u4eea","\u9176\u6807\u4eea"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/","name":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg","datePublished":"2026-02-27T05:57:13+00:00","dateModified":"2026-03-09T05:53:00+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u672c\u6307\u5357\u8be6\u7ec6\u89e3\u6790\u4e86\u5fae\u5b54\u677f\u8bfb\u6570\u4eea\u4e2d\u5355\u8272\u5668\u548c\u6ee4\u5149\u7247\u7684\u5149\u5b66\u673a\u5236\uff0c\u5e76\u6bd4\u8f83\u4e86\u5b83\u4eec\u5404\u81ea\u7684\u4f18\u7f3a\u70b9\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image.jpg","width":1500,"height":979},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/monochromator-or-filter-based-plate-reader\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u9176\u6807\u4eea\u9009\u62e9\uff0c\u5355\u8272\u4eea\u578b\u8fd8\u662f\u6ee4\u5149\u7247\u578b\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":41,"label":"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea"},{"value":40,"label":"\u9176\u6807\u4eea"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/Plate-Reader-Image-1024x668.jpg",760,496,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u5fae\u5b54\u677f\u8bfb\u6570\u4eea","slug":"%e5%be%ae%e5%ad%94%e6%9d%bf%e8%af%bb%e6%95%b0%e4%bb%aa","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":40,"name":"\u9176\u6807\u4eea","slug":"%e9%85%b6%e6%a0%87%e4%bb%aa","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/558","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=558"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/558\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/559"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=558"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=558"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=558"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=558"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}