{"id":561,"date":"2026-03-02T03:49:27","date_gmt":"2026-03-02T03:49:27","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=561"},"modified":"2026-03-09T05:50:20","modified_gmt":"2026-03-09T05:50:20","slug":"dna-extraction-guide-mastering-7-essential-sample-types","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/","title":{"rendered":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE0.jpg\" alt=\"DNA Extraction Guide cover image\" class=\"wp-image-4957\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u6548\u7684DNA\u63d0\u53d6\u662f\u5168\u7403\u5206\u5b50\u751f\u7269\u5b66\u7814\u7a76\u3001\u8bca\u65ad\u548c\u6cd5\u533b\u5b66\u5e94\u7528\u7684\u57fa\u77f3\u3002\u65e0\u8bba\u60a8\u662f\u5728\u4e34\u5e8a\u5b9e\u9a8c\u5ba4\u5904\u7406\u8840\u6db2\u6837\u672c\u3001\u5728\u519c\u4e1a\u7814\u7a76\u4e2d\u5206\u6790\u690d\u7269\u7ec4\u7ec7\uff0c\u8fd8\u662f\u5728\u764c\u75c7\u7814\u7a76\u4e2d\u4f7f\u7528FFPE\u6837\u672c\uff0c\u6bcf\u79cd\u6837\u672c\u7c7b\u578b\u90fd\u9762\u4e34\u72ec\u7279\u7684\u6311\u6218\uff0c\u9700\u8981\u91c7\u7528\u4e13\u4e1a\u7684\u65b9\u6cd5\u52a0\u4ee5\u5e94\u5bf9\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u672c\u6307\u5357\u4e2d\uff0c\u6211\u4eec\u5c06\u63a2\u8ba8DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u91cd\u70b9\u4ecb\u7ecd\u6ee1\u8db3\u751f\u7269\u6280\u672f\u9886\u57df\u7814\u7a76\u4eba\u5458\u591a\u6837\u5316\u9700\u6c42\u7684\u5148\u8fdb\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-yoast-seo-table-of-contents yoast-table-of-contents\"><h2>\u76ee\u5f55<\/h2><ul><li><a href=\"#h-\u4e3a\u4ec0\u4e48dna\u63d0\u53d6\u8d28\u91cf\u5f88\u91cd\u8981\" data-level=\"2\">\u4e3a\u4ec0\u4e48DNA\u63d0\u53d6\u8d28\u91cf\u5f88\u91cd\u8981\uff1f<\/a><\/li><li><a href=\"#h-dna\u63d0\u53d6\u6d41\u7a0b\u4e00\u89c8\" data-level=\"2\">DNA\u63d0\u53d6\u6d41\u7a0b\u4e00\u89c8<\/a><\/li><li><a href=\"#h-\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u7684dna\u63d0\u53d6\u6311\u6218\" data-level=\"2\">\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u7684DNA\u63d0\u53d6\u6311\u6218<\/a><ul><li><a href=\"#h-\u8840\u6db2\u53ca\u4f53\u6db2\u6837\u672c\" data-level=\"3\">\u8840\u6db2\u53ca\u4f53\u6db2\u6837\u672c<\/a><\/li><li><a href=\"#h-\u7ec4\u7ec7\u6837\u672c\" data-level=\"3\">\u7ec4\u7ec7\u6837\u672c<\/a><\/li><li><a href=\"#h-\u7ec6\u80de\u57f9\u517b\" data-level=\"3\">\u7ec6\u80de\u57f9\u517b<\/a><\/li><li><a href=\"#h-\u53e3\u8154\u62ed\u5b50\u6216\u5e72\u62ed\u5b50\" data-level=\"3\">\u53e3\u8154\u62ed\u5b50\u6216\u5e72\u62ed\u5b50<\/a><\/li><li><a href=\"#h-\u542b\u4ecb\u8d28\u7684\u6837\u672c-\u7caa\u4fbf-\u62ed\u5b50-\u553e\u6db2\" data-level=\"3\">\u542b\u4ecb\u8d28\u7684\u6837\u672c\uff08\u7caa\u4fbf\u3001\u62ed\u5b50\u3001\u553e\u6db2\uff09<\/a><\/li><li><a href=\"#h-\u690d\u7269\u6837\u672c\" data-level=\"3\">\u690d\u7269\u6837\u672c<\/a><\/li><li><a href=\"#h-\u798f\u5c14\u9a6c\u6797\u56fa\u5b9a\u77f3\u8721\u5305\u57cb-ffpe-\u6837\u672c\" data-level=\"3\">\u798f\u5c14\u9a6c\u6797\u56fa\u5b9a\u77f3\u8721\u5305\u57cb\uff08FFPE\uff09\u6837\u672c<\/a><\/li><\/ul><\/li><li><a href=\"#h-\u901a\u8fc7\u81ea\u52a8\u5316\u5c06\u4e0d\u540c\u5de5\u4f5c\u6d41\u7a0b\u7b80\u5316\u4e3a\u5355\u4e00\u89e3\u51b3\u65b9\u6848\" data-level=\"2\">\u901a\u8fc7\u81ea\u52a8\u5316\u5c06\u4e0d\u540c\u5de5\u4f5c\u6d41\u7a0b\u7b80\u5316\u4e3a\u5355\u4e00\u89e3\u51b3\u65b9\u6848<\/a><\/li><li><a href=\"#h-\u6458\u8981\" data-level=\"2\">\u6458\u8981<\/a><\/li><li><a href=\"#h-\u66f4\u591adna\u63d0\u53d6\u5b66\u4e60\u4e0e\u8d44\u6e90\" data-level=\"2\">\u66f4\u591aDNA\u63d0\u53d6\u5b66\u4e60\u4e0e\u8d44\u6e90<\/a><ul><li><a href=\"#h-\u5b9e\u9a8c\u65b9\u6848\u548c\u5e94\u7528\u8bf4\u660e\" data-level=\"3\">\u5b9e\u9a8c\u65b9\u6848\u548c\u5e94\u7528\u8bf4\u660e<\/a><\/li><\/ul><\/li><\/ul><\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-fill\"><a class=\"wp-block-button__link has-white-color has-text-color has-background has-link-color has-medium-font-size has-text-align-center has-custom-font-size wp-element-button\" href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/dna-rna-purification-analysis.html#na-extraction-methods\" style=\"border-radius:0px;background-color:#ee3134\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>\u63a2\u7d22DNA\u63d0\u53d6\u6280\u672f<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e3a\u4ec0\u4e48dna\u63d0\u53d6\u8d28\u91cf\u5f88\u91cd\u8981\">\u4e3a\u4ec0\u4e48DNA\u63d0\u53d6\u8d28\u91cf\u5f88\u91cd\u8981\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DNA\u5206\u6790\u662f\u4f17\u591a\u79d1\u5b66\u5e94\u7528\u7684\u57fa\u77f3\uff0c\u5305\u62ec\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9057\u4f20\u7814\u7a76\u63a2\u7d22<\/strong>\u6d89\u53ca\u4eba\u7c7b\u57fa\u56e0\u7ec4\u7ed8\u56fe\u3001\u57fa\u56e0\u514b\u9686\u548c\u529f\u80fd\u57fa\u56e0\u7ec4\u5b66<\/li>\n\n\n\n<li><strong>\u672a\u6765\u4e34\u5e8a\u8bca\u65ad\u7684\u53d1\u5c55<\/strong>\u6db5\u76d6\u75be\u75c5\u7814\u7a76\u4e2d\u7684\u53d1\u73b0\u3001\u75c5\u539f\u4f53\u53d1\u73b0\u3001\u4e2a\u6027\u5316\u533b\u5b66\u7684\u5f00\u53d1<\/li>\n\n\n\n<li><strong>\u6cd5\u533b\u5206\u6790<\/strong>\u5305\u62ecDNA\u9274\u5b9a\u548c\u4eb2\u5b50\u9274\u5b9a<\/li>\n\n\n\n<li><strong>\u836f\u7269\u7814\u53d1<\/strong>\u6db5\u76d6\u57fa\u56e0\u6cbb\u7597\u548c\u91cd\u7ec4\u86cb\u767d\u751f\u4ea7\u9886\u57df<\/li>\n\n\n\n<li><strong>\u519c\u4e1a\u751f\u7269\u6280\u672f\u7684\u53d1\u5c55<\/strong>\u5728\u57fa\u56e0\u5de5\u7a0b\u548c\u6807\u8bb0\u8f85\u52a9\u9009\u62e9\u4e2d<\/li>\n\n\n\n<li><strong>\u73af\u5883\u751f\u7269\u6280\u672f\u7684\u63a2\u7d22<\/strong>\u7ed3\u5408\u751f\u7269\u591a\u6837\u6027\u7814\u7a76\u4e0e\u751f\u7269\u4fee\u590d<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u6ca1\u6709\u9ad8\u8d28\u91cf\u7684\u63d0\u53d6\uff0c\u8fd9\u4e9b\u5e94\u7528\u90fd\u65e0\u6cd5\u5b9e\u73b0\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-dna\u63d0\u53d6\u6d41\u7a0b\u4e00\u89c8\">DNA\u63d0\u53d6\u6d41\u7a0b\u4e00\u89c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6709\u51e0\u79cd\u5206\u79bbDNA\u7684\u65b9\u6cd5\uff0c\u5305\u62ec\u6709\u673a\u5206\u79bb\u3001\u901a\u8fc7\u8fc7\u6ee4\u6216\u6c89\u6dc0\u8fdb\u884c\u5206\u79bb\uff0c\u4ee5\u53ca\u5229\u7528\u78c1\u73e0\u6765\u6e90\u8fdb\u884c\u5206\u79bb\u3002\u6240\u6709\u65b9\u6cd5\u90fd\u9075\u5faa\u6807\u51c6\u7684\u64cd\u4f5c\u987a\u5e8f\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u7ec6\u80de\u88c2\u89e3<\/li>\n\n\n\n<li>\u7ed3\u5408\u6216\u6c89\u6dc0<\/li>\n\n\n\n<li>\u5bf9\u7ed3\u5408\u6216\u6c89\u6dc0\u7684DNA\u8fdb\u884c\u6d17\u6da4<\/li>\n\n\n\n<li>\u6d17\u8131\u6216\u91cd\u60ac\u4e8e\u5de5\u4f5c\u7f13\u51b2\u6db2\u4e2d\u4ee5\u4f9b\u540e\u7eed\u4f7f\u7528<\/li>\n<\/ol>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u7684dna\u63d0\u53d6\u6311\u6218\">\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u7684DNA\u63d0\u53d6\u6311\u6218<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0d\u540c\u7c7b\u578b\u7684\u6837\u672c\u5728DNA\u63d0\u53d6\u8fc7\u7a0b\u4e2d\u4f1a\u9762\u4e34\u7279\u5b9a\u7684\u6311\u6218\uff0c\u8fd9\u4e9b\u6311\u6218\u8fd8\u53d7\u5230\u6837\u672c\u4f53\u79ef\u3001DNA\u5206\u5b50\u5927\u5c0f\u4ee5\u53ca\u4e0b\u6e38\u5206\u6790\u6240\u9700\u76ee\u6807\u6d53\u5ea6\u7b49\u53d8\u91cf\u7684\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b\u5982\uff0c\u8840\u6db2\u6837\u672c\u4e2d\u542b\u6709\u53ef\u80fd\u5f71\u54cd\u540e\u7eed\u6d41\u7a0b\u7684\u6291\u5236\u5242\uff1b\u690d\u7269\u7ec4\u7ec7\u5177\u6709\u575a\u786c\u7684\u7ec6\u80de\u58c1\uff0c\u589e\u52a0\u4e86\u7ec6\u80de\u88c2\u89e3\u7684\u96be\u5ea6\uff1b\u7ec4\u7ec7\u6837\u672c\u5e38\u5e38\u5b58\u5728DNA\u964d\u89e3\u7684\u95ee\u9898\uff0c\u800c\u5fae\u751f\u7269\u6837\u672c\u5219\u62e5\u6709\u575a\u56fa\u7684\u7ec6\u80de\u58c1\uff0c\u5bf9\u6807\u51c6\u63d0\u53d6\u65b9\u6cd5\u6709\u8f83\u5f3a\u62b5\u6297\u529b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcf\u79cd\u6837\u672c\u7c7b\u578b\u2014\u2014\u5982\u8840\u6db2\u3001\u7ec4\u7ec7\u3001\u7ec6\u80de\u57f9\u517b\u7269\u3001\u690d\u7269\u6750\u6599\u548c\u5fae\u751f\u7269\u6837\u672c\u2014\u2014\u90fd\u9700\u8981\u91c7\u7528\u4e13\u95e8\u7684\u65b9\u6cd5\uff0c\u4ee5\u786e\u4fdd\u9ad8\u6548\u4e14\u9ad8\u8d28\u91cf\u5730\u63d0\u53d6DNA\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7406\u89e3\u8fd9\u4e9b\u4e0e\u5177\u4f53\u6837\u672c\u76f8\u5173\u7684\u6311\u6218\uff0c\u5e76\u91c7\u53d6\u5408\u9002\u7684\u63d0\u53d6\u7b56\u7565\uff0c\u5bf9\u4e8e\u5728\u5206\u5b50\u751f\u7269\u5b66\u5de5\u4f5c\u6d41\u7a0b\u4e2d\u83b7\u5f97\u53ef\u9760\u7ed3\u679c\u81f3\u5173\u91cd\u8981\u3002\u672c\u6307\u5357\u5c06\u63a2\u8ba8\u5404\u79cd\u6837\u672c\u7c7b\u578b\u6240\u9762\u4e34\u7684\u72ec\u7279\u95ee\u9898\uff0c\u5e76\u63d0\u4f9b\u5207\u5b9e\u53ef\u884c\u7684\u89e3\u51b3\u65b9\u6848\uff0c\u4ee5\u514b\u670d\u8fd9\u4e9b\u969c\u788d\uff0c\u4ece\u800c\u786e\u4fdd\u6210\u529f\u5b9e\u73b0DNA\u5206\u79bb\u53ca\u540e\u7eed\u5206\u6790\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u8840\u6db2\u53ca\u4f53\u6db2\u6837\u672c\">\u8840\u6db2\u53ca\u4f53\u6db2\u6837\u672c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u8840\u6db2\u3001\u553e\u6db2\u3001\u5c3f\u6db2\u53ca\u5176\u4ed6\u4f53\u6db2\u6837\u672c\u901a\u5e38\u542b\u6709\u5982\u8840\u7ea2\u7d20\u6216\u9ecf\u86cb\u767d\u7b49\u6291\u5236\u5242\uff0c\u8fd9\u4e9b\u6210\u5206\u53ef\u80fd\u963b\u788d\u6d4b\u5e8f\u548cPCR\u7b49\u4e0b\u6e38\u5206\u5b50\u5e94\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u4ece\u8fd9\u4e9b\u7c7b\u578b\u7684\u6837\u672c\u4e2d\u63d0\u53d6DNA\uff0c\u9700\u8981\u8003\u8651\u52a0\u70ed\u548c\u6df7\u5300\u7b49\u64cd\u4f5c\u6b65\u9aa4\uff0c\u8fd9\u4e9b\u6b65\u9aa4\u6709\u52a9\u4e8e\u5b9e\u73b0\u5f3a\u529b\u4f46\u96c6\u4e2d\u7684\u88c2\u89e3\u548c\u6d88\u5316\uff0c\u4ece\u800c\u7834\u574f\u7ec6\u80de\u7ed3\u6784\u800c\u4e0d\u635f\u4f24DNA\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u79fb\u690d\u8bca\u65ad\uff08\u5982\u4eba\u7c7b\u767d\u7ec6\u80de\u6297\u539f[HLA]\u57fa\u56e0\u9274\u5b9a\uff09\u6216\u4e0b\u4e00\u4ee3\u6d4b\u5e8f\uff08NGS\uff09\u7b49\u5e94\u7528\u6765\u8bf4\uff0c\u4fdd\u6301\u6837\u54c1\u5206\u6790\u7684\u4e00\u81f4\u6027\u548c\u8db3\u591f\u4f53\u79ef\u975e\u5e38\u5173\u952e\u3002\u78c1\u73e0\u6cd5\u5de5\u4f5c\u6d41\u7a0b\u53ef\u4ee5\u5e2e\u52a9\u63d0\u9ad8\u6837\u54c1\u901a\u91cf\u548c\u5747\u4e00\u6027\uff0c\u4ece\u800c\u83b7\u5f97\u9ad8\u8d28\u91cf\u7684\u57fa\u56e0\u7ec4DNA\u7ed3\u679c\u3002<\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab606f9&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab606f9\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE1-1024x203.png\" alt=\"Average gDNA concentration, size, quality and purity in isolated DNA sample \" class=\"wp-image-4950\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe1 \u2013 \u4f7f\u7528MagMAX\u2122 DNA Multi-Sample Ultra 2.0\u8bd5\u5242\u76d2\u5728KingFisher Apex\u7eaf\u5316\u7cfb\u7edf\u4e0a\uff0c\u4ece96\u4efd\u8840\u6db2\u6837\u54c1\u4e2d\u5206\u79bb\u5f97\u5230\u57fa\u56e0\u7ec4DNA\uff08gDNA\uff09\u7684\u5e73\u5747\u6d53\u5ea6\u3001\u7247\u6bb5\u5927\u5c0f\u3001\u8d28\u91cf\u53ca\u7eaf\u5ea6\u6570\u636e\u3002\u4f7f\u7528Qubit dsDNA BR Assay\u8bd5\u5242\u76d2\u5728Varioskan LUX\u591a\u529f\u80fd\u9176\u6807\u4eea\u4e0a\u83b7\u5f97\u6d53\u5ea6\u6570\u636e\uff1b\u5229\u7528Agilent 4200 TapeStation\u5e73\u53f0\u4e0a\u7684genomic DNA ScreenTape\u88c5\u7f6e\u83b7\u53d6\u7247\u6bb5\u5927\u5c0f\u53caDIN\u8bc4\u5206\uff1b\u901a\u8fc7NanoDrop\u5206\u5149\u5149\u5ea6\u8ba1\u83b7\u5f97\u7eaf\u5ea6\u4e0e\u8d28\u91cf\u5438\u6536\u6bd4\u503c\u3002\u672c\u7814\u7a76\u66f4\u591a\u4fe1\u606f\u8be6\u89c1<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/human-leukocyte-antigen-testing-peripheral-blood-app-note.pdf\">\u7528\u4e8e\u5916\u5468\u8840\u7684\u4eba\u7c7b\u767d\u7ec6\u80de\u6297\u539f\u68c0\u6d4b\u7684\u591a\u529f\u80fd\u89e3\u51b3\u65b9\u6848<\/a>\uff089\uff09\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7ec4\u7ec7\u6837\u672c\">\u7ec4\u7ec7\u6837\u672c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u88c2\u89e3\u6548\u7387\u53d6\u51b3\u4e8e\u6837\u54c1\u4e2d\u4e0d\u540c\u3001\u7ec4\u7ec7\u7279\u5f02\u6027\u7684\u7ec6\u80de\u7ed3\u6784\uff0c\u5982\u809d\u810f\u3001\u808c\u8089\u3001\u5fc3\u810f\u3001\u5927\u8111\u53ca\u5176\u4ed6\u7ec4\u7ec7\u3002\u7ec4\u7ec7\u901a\u5e38\u5177\u6709\u7ea4\u7ef4\u6027\u4e14\u575a\u97e7\uff0c\u7ec6\u80de\u58c1\u521a\u6027\uff0c\u9700\u8981\u901a\u8fc7\u5747\u8d28\u5316\u6216\u73e0\u78e8\u8fdb\u884c\u673a\u68b0\u7834\u788e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5747\u8d28\u5668\uff0c\u4f8b\u5982<a href=\"https:\/\/www.fishersci.com\/shop\/products\/fisher-850-homogenizer\/15340169#?keyword=\">Fisherbrand\u2122 850 \u5747\u8d28\u5668<\/a>\uff0c\u901a\u5e38\u6bd4\u73e0\u78e8\u65b9\u6cd5\u83b7\u5f97\u66f4\u9ad8\u7684DNA\u4ea7\u91cf\u3002\u5982\u679c\u6ca1\u6709\u624b\u52a8\u5747\u8d28\u5668\uff0c\u7814\u7a76\u4eba\u5458\u53ef\u4ee5\u9009\u62e9\u8c28\u614e\u7684\u73e0\u78e8\u2014\u2014\u7c97\u7cd9\u7684\u4e0a\u6e05\u6db2\u6df7\u5408\u53ef\u80fd\u4f1a\u5bfc\u81f4\u4ea7\u751f\u6ce1\u6cab\u72b6\u7684\u5747\u8d28\u6db2\uff0c\u8fd9\u53ef\u80fd\u96be\u4ee5\u8f6c\u79fb\u5230\u6837\u54c1\u5206\u79bb\u6b65\u9aa4\u4e2d\u3002\u52a0\u5165RNase\u5904\u7406\u4e5f\u6709\u52a9\u4e8e\u51cf\u5c11\u6837\u54c1\u4e2d\u7684RNA\u6c61\u67d3\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u52a0\u5165RNase\u5904\u7406\u4e5f\u6709\u52a9\u4e8e\u51cf\u5c11\u6837\u54c1\u4e2d\u7684RNA\u6c61\u67d3\u3002\u4e0b\u56fe\u5c55\u793a\u4e86\u4f7f\u7528MagMAX DNA Multi-Sample Ultra 2.0\u8bd5\u5242\u548cApplied Biosystems\u2122 MagMAX\u2122\u7ec6\u80de\u4e0e\u7ec4\u7ec7DNA\u63d0\u53d6\u7f13\u51b2\u6db2\uff0c\u5728KingFisher\u4eea\u5668\u4e0a\u5bf9\u5c0f\u9f20\u8111\u3001\u5fc3\u810f\u3001\u80be\u810f\u3001\u809d\u810f\u3001\u80ba\u3001\u80f0\u817a\u3001\u813e\u548c\u80f8\u817a\u7ec4\u7ec7\u8fdb\u884c\u5206\u79bb\u65f6\uff0c\u5728\u6709\u65e0RNase A\u5904\u7406\u60c5\u51b5\u4e0b\u83b7\u5f97\u7684DNA\u4ea7\u91cf\u6bd4\u8f83\u3002<\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab611dd&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab611dd\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE2-1024x707.png\" alt=\"Mouse tissue DNA concentrations extracted using automated tools\" class=\"wp-image-4951\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe2 \u2013 \u4f7f\u7528KingFisher\u4eea\u5668\u4e0a\u7684MagMAX DNA Multi-Sample Ultra 2.0\u4e0e\u7ec6\u80de\u548c\u7ec4\u7ec7\u63d0\u53d6\u7f13\u51b2\u6db2\u5206\u79bb\u7684\u5c0f\u9f20\u7ec4\u7ec7\u6d53\u5ea6\u3002\u6d53\u5ea6\u91c7\u7528Invitrogen\u2122 Qubit DNA BR\u8bd5\u5242\u6d4b\u5b9a\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u6765\u8bf4\uff0c\u6295\u5165\u63d0\u53d6\u7684\u7ec4\u7ec7\u8d8a\u591a\uff0c\u4ea7\u91cf\u4e5f\u4f1a\u8d8a\u9ad8\u3002\u56fe4\u8be6\u7ec6\u5c55\u793a\u4e86\u4e0d\u540c\u6837\u672c\u8f93\u5165\u91cf\u4e0b\u5206\u79bb\u7684\u5c0f\u9f20\u809d\u7ec4\u7ec7\u53ca\u5176\u603b\u4ea7\u91cf\u3002\u5178\u578b\u7684\u8d28\u91cf\u5438\u5149\u6bd4A260\/A280\u5e73\u5747\u901a\u5e38\u5927\u4e8e\u6216\u7b49\u4e8e1.6\u3002<\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab61aeb&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab61aeb\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNA3-1024x572.png\" alt=\"Liver tissue DNA yields from mice \" class=\"wp-image-4952\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe3 \u2013 \u4f7f\u7528KingFisher\u4eea\u5668\u4e0a\u7684MagMAX DNA Multi-Sample Ultra 2.0\u4e0e\u7ec6\u80de\u548c\u7ec4\u7ec7\u63d0\u53d6\u7f13\u51b2\u6db2\u5206\u79bb\u7684\u5c0f\u9f20\u809d\u7ec4\u7ec7\u4ea7\u91cf\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7ec6\u80de\u57f9\u517b\">\u7ec6\u80de\u57f9\u517b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u4ece\u7ec6\u80de\u57f9\u517b\u7269\u4e2d\u5206\u79bbDNA\u65f6\uff0c\u9700\u8981\u76d1\u63a7\u7ec6\u80de\u6d3b\u6027\u3001\u6d53\u5ea6\uff0c\u5e76\u5728\u6269\u589e\u8fc7\u7a0b\u4e2d\u4fdd\u6301\u6700\u4f73\u5bc6\u5ea6\u3002\u5bf9\u4e8eT\u7ec6\u80de\uff0c\u5c24\u5176\u8981\u4ed4\u7ec6\u63a7\u5236\u57f9\u517b\u6761\u4ef6\u5e76\u5b9a\u671f\u8fdb\u884c\u8d28\u91cf\u68c0\u67e5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u5982Gibco\u2122 CTS\u2122 OpTmizer\u2122 T Cell Expansion SFM\u548cInvitrogen\u2122 Dynabeads\u2122 Human T-Activator CD3\/CD28\u7b49\u4e13\u7528\u8bd5\u5242\uff0c\u6709\u52a9\u4e8e\u4f18\u5316\u60a8\u7684\u6d41\u7a0b\u3002Countess II FL\u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea\u7b49\u5de5\u5177\u53ef\u6709\u6548\u76d1\u63a7\u60a8\u7684\u57f9\u517b\u7269\uff0c\u4ee5\u5b9e\u73b0\u53ef\u9760\u7684DNA\u5206\u79bb\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6709\u5173\u7ec6\u80de\u6269\u589e\u671f\u95f4\u8d28\u91cf\u63a7\u5236\u7684\u66f4\u591a\u8be6\u60c5\uff0c\u8bf7\u53c2\u9605\u5e94\u7528\u8bf4\u660e\u201c<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/cell-culture-quality-control-during-t-cell-expansion-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">T\u7ec6\u80de\u6269\u589e\u8fc7\u7a0b\u4e2d\u7684\u7ec6\u80de\u57f9\u517b\u8d28\u91cf\u63a7\u5236<\/a>\u201d\u3002<\/p>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u53e3\u8154\u62ed\u5b50\u6216\u5e72\u62ed\u5b50\">\u53e3\u8154\u62ed\u5b50\u6216\u5e72\u62ed\u5b50<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u53e3\u8154\u62ed\u5b50\u548c\u5e72\u62ed\u5b50\u5177\u6709\u6311\u6218\u6027\uff0c\u56e0\u4e3a\u50a8\u5b58\u8fc7\u7a0b\u4e2d\u5e38\u5e38\u53d1\u751f\u7ec6\u83cc\u751f\u957f\u3002\u53e3\u8154\u5fae\u751f\u7269\u7ec4\u3001\u76ae\u80a4\u4ee5\u53ca\u5176\u4ed6\u6837\u672c\u6765\u6e90\u542b\u6709\u5927\u91cf\u7ec6\u83cc\u548c\u6c61\u67d3\u7269\uff0c\u56e0\u6b64\u6b63\u786e\u7684\u5e72\u71e5\u3001\u50a8\u5b58\u548c\u63d0\u53d6\u6d41\u7a0b\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u78c1\u73e0\u6cd5\u914d\u5408\u4f18\u5316\u7684\u5316\u5b66\u8bd5\u5242\u80fd\u591f\u6709\u6548\u5730\u9776\u5411\u57fa\u56e0\u7ec4\u548c\u5fae\u751f\u7269DNA\uff0c\u540c\u65f6\u53bb\u9664\u6837\u672c\u7279\u5f02\u6027\u6291\u5236\u5242\uff08\u89c1\u56fe5\uff09\u3002\u5373\u4f7f\u62e5\u6709\u4f18\u826f\u7684\u5316\u5b66\u53cd\u5e94\u4f53\u7cfb\uff0c\u60a8\u4ecd\u5e94\u9075\u5faa\u53e3\u8154\u62ed\u5b50\u5206\u79bb\u7684\u6700\u4f73\u5b9e\u8df5\uff08\u89c1\u56fe6\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5efa\u8bae\u5728\u4e00\u6b21\u5206\u79bb\u4e2d\u4f7f\u7528\u4e24\u6839\u62ed\u5b50\uff0c\u4ee5\u63d0\u9ad8\u4ea7\u91cf\u3002\u5ef6\u957f\u88c2\u89e3\u9636\u6bb5\u4e5f\u80fd\u63d0\u5347\u56de\u6536\u7387\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab6284e&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab6284e\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE4-1024x407.png\" alt=\"Total extracted DNA yield and purity measured by nanodrop from buccal swab samples processed with automated tools \" class=\"wp-image-4953\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe4 \u2013 \u603bDNA\u4ea7\u91cf\u4e0e\u7eaf\u5ea6\u901a\u8fc7\u7eb3\u7c73\u6ef4\u5b9a\u4eea\u6d4b\u91cf\uff0c\u7528MagMAX DNA Multi-Sample Ultra 2.0\u548cMagMAX Microbiome\u8bd5\u5242\u76d2\u5728KingFisher\u4eea\u5668\u4e0a\uff0c\u4ece8\u4efd\u5339\u914d\u7684\u53e3\u8154\u62ed\u5b50\u6837\u672c\u4e2d\u5206\u79bb\u83b7\u5f97\uff0c\u5305\u62ec\u65b0\u9c9c\u5206\u79bb\u3001\u5ba4\u6e29\u5b58\u50a8\u4e24\u5468\u4ee5\u53ca\u51b7\u51bb\u4e24\u5468\u3002\u66f4\u591a\u8be6\u60c5\u53ef\u53c2\u89c1<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/posters\/effects-swab-storage-nucleic-acid-poster.pdf\">\u6b64\u6d77\u62a5<\/a>\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab630e7&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab630e7\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE5-1024x388.png\" alt=\"Best practices for the collection of buccal swabs\" class=\"wp-image-4954\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u91c7\u96c6\u53e3\u8154\u62ed\u5b50\u7684\u901a\u7528\u6700\u4f73\u5b9e\u8df5\u3002\u66f4\u591a\u7ec6\u8282\u53ef\u53c2\u8003\u6b64\u5feb\u901f\u6307\u5357\uff1a<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/LSG\/Product-Guides\/MAN0014348_Buccal_Swab_Collection_QR.pdf\">\u53e3\u8154\u62ed\u5b50\u91c7\u96c6\u6700\u4f73\u5b9e\u8df5\u5feb\u901f\u53c2\u8003\uff08\u57fa\u56e0\u5206\u578b\u5b9e\u9a8c\uff09\uff08\u51fa\u7248\u53f7\uff1aMAN0014348 Rev. A.0\uff09<\/a><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u542b\u4ecb\u8d28\u7684\u6837\u672c-\u7caa\u4fbf-\u62ed\u5b50-\u553e\u6db2\">\u542b\u4ecb\u8d28\u7684\u6837\u672c\uff08\u7caa\u4fbf\u3001\u62ed\u5b50\u3001\u553e\u6db2\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7a33\u5b9a\u5242\u4ecb\u8d28\u6709\u52a9\u4e8e\u901a\u8fc7\u9632\u6b62\u73af\u5883\u56e0\u7d20\u3001\u7ec6\u83cc\u751f\u957f\u548c\u6291\u5236\u5242\u5bfc\u81f4\u7684\u964d\u89e3\u6765\u4fdd\u62a4\u6837\u672c\u5b8c\u6574\u6027\u3002\u8fd9\u4e9b\u4ecb\u8d28\u53ef\u5ef6\u957f\u5b58\u50a8\u8d27\u67b6\u671f\u5e76\u63d0\u5347\u5b9e\u9a8c\u4e00\u81f4\u6027\u3002\u5bf9\u4e8e\u553e\u6db2\u6837\u672c\uff0c\u7a33\u5b9a\u5316\u91c7\u96c6\u88c5\u7f6e\u80fd\u6709\u6548\u4fdd\u5b58\u7528\u4e8eGWAS\u7814\u7a76\u7684\u57fa\u56e0\u7ec4\u6807\u8bb0\u5982APOE\u3002\u7814\u7a76\u8868\u660e\uff0c\u4e0e\u539f\u59cb\u553e\u6db2\u6837\u672c\u76f8\u6bd4\uff0c\u8fd9\u4e9b\u88c5\u7f6e\u5728\u5b58\u50a8\u671f\u95f4\u80fd\u51cf\u5c11\u7ec6\u83ccDNA\u542b\u91cf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u60a8\u5c06\u7caa\u4fbf\u3001\u553e\u6db2\u548c\u62ed\u5b50\u7b49\u6837\u672c\u7a00\u91ca\u5230\u7a33\u5b9a\u5242\u4ecb\u8d28\u4e2d\u65f6\uff0c\u901a\u5e38\u4f1a\u83b7\u5f97\u6bd4\u975e\u7a33\u5b9a\u6750\u6599\u5c0f\u4f53\u79ef\u66f4\u4f4e\u7684DNA\u4ea7\u91cf\u3002\u56e0\u6b64\uff0c\u8bf7\u4e3a\u60a8\u7684\u6837\u672c\u8f93\u5165\u9884\u7559\u7075\u6d3b\u7a7a\u95f4\uff0c\u4ee5\u4fbf\u8c03\u6574\u4f53\u79ef\u4ee5\u6ee1\u8db3\u4e0b\u6e38\u68c0\u6d4b\u5bf9DNA\u4ea7\u91cf\u7684\u9700\u6c42\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab6398f&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab6398f\" class=\"aligncenter size-full wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE6.png\" alt=\"Comparison of bacterial DNA in saliva samples\" class=\"wp-image-4955\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe6 \u2013 \u6bd4\u8f83\u6765\u81ea\u5065\u5eb7\u6350\u732e\u8005\u7684\u5339\u914d\u553e\u6db2\u6837\u672c\u4e2d\u9274\u5b9a\u51fa\u7684\u603b\u7ec6\u83ccDNA\u767e\u5206\u6bd4\uff0c\u5305\u62ec\u539f\u59cb\u548c\u672a\u7a33\u5b9a\u5904\u7406\u3001\u4f7f\u7528SDNA-1000\u8bbe\u5907\u7a33\u5b9a\u3001\u4f7f\u7528OGR-600\u8bbe\u5907\u7a33\u5b9a\uff0c\u4ee5\u53ca\u4f7f\u7528SpeciMAX Stabilized\u8bbe\u5907\u7a33\u5b9a\uff0c\u4ece\u91c7\u96c6\u540e3\u5929\u523014\u5929\u3002\u6709\u5173\u8be5\u7814\u7a76\u7684\u66f4\u591a\u4fe1\u606f\uff0c\u8bf7\u53c2\u89c1\u201c<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/comparative-study-saliva-collection-devices-axiom-human-genotyping-arrays-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u4f7f\u7528Axiom\u4eba\u7c7b\u57fa\u56e0\u5206\u578b\u82af\u7247\u5bf9\u553e\u6db2\u91c7\u96c6\u8bbe\u5907\u7684\u6bd4\u8f83\u7814\u7a76<\/a>\u201d\u6240\u5c55\u793a\u7684\u90a3\u6837\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u690d\u7269\u6837\u672c\">\u690d\u7269\u6837\u672c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ece\u690d\u7269\u4e2d\u5206\u79bbDNA\u5177\u6709\u6311\u6218\u6027\uff0c\u56e0\u4e3a\u5b83\u4eec\u575a\u786c\u7684\u7ec6\u80de\u58c1\u4ee5\u53ca\u591a\u7cd6\u548c\u591a\u915a\u7b49\u6b21\u7ea7\u4ee3\u8c22\u4ea7\u7269\u4f1a\u6c61\u67d3DNA\u5e76\u5e72\u6270\u540e\u7eed\u5e94\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f60\u53ef\u4ee5\u9009\u62e9\u4e13\u7528\u8bd5\u5242\u76d2\uff0c\u5982Thermo Scientific\u2122 GeneJET\u2122\u690d\u7269\u57fa\u56e0\u7ec4DNA\u7eaf\u5316\u8bd5\u5242\u76d2\uff0814\uff09\u6216Thermo Scientific\u2122 MagMAX\u2122\u690d\u7269DNA\u5206\u79bb\u8bd5\u5242\u76d2\uff0815\uff09\uff0c\u8fd9\u4e9b\u8bd5\u5242\u76d2\u542b\u6709PVP\u4ee5\u51cf\u5c11\u591a\u915a\u6291\u5236\u3002\u4f60\u8fd8\u53ef\u4ee5\u901a\u8fc7\u5c06PVP\u6280\u672f\u5e94\u7528\u4e8e\u80cd\u76d0\u6eb6\u6db2\uff0c\u8c03\u6574\u690d\u7269\u5de5\u4f5c\u6d41\u7a0b\u4ee5\u5b9e\u73b0\u81ea\u52a8\u5316\uff0c\u6b63\u5982\u7f51\u7edc\u7814\u8ba8\u4f1a\u201c<a href=\"https:\/\/www.youtube.com\/watch?v=CutvwuWKzEs\">\u6811\u6728\u75be\u75c5\u7814\u7a76\u5b9e\u9a8c\u5ba4\u4e2d\u7684\u9ad8\u901a\u91cf\u81ea\u52a8\u5316\u2014\u2014\u4e00\u540d\u5206\u5b50\u6280\u672f\u5458\u7684\u63a2\u7d22\u4e4b\u65c5<\/a>\u201d\u6240\u5c55\u793a\u7684\u90a3\u6837\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u798f\u5c14\u9a6c\u6797\u56fa\u5b9a\u77f3\u8721\u5305\u57cb-ffpe-\u6837\u672c\">\u798f\u5c14\u9a6c\u6797\u56fa\u5b9a\u77f3\u8721\u5305\u57cb\uff08FFPE\uff09\u6837\u672c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FFPE\u6837\u672c\u662f\u6700\u5177\u6311\u6218\u6027\u7684DNA\u5206\u79bb\u5bf9\u8c61\u4e4b\u4e00\uff0c\u56e0\u4e3a\u7532\u919b\u56fa\u5b9a\u548c\u77f3\u8721\u5305\u57cb\u9700\u8981\u5728\u83b7\u53d6\u6838\u9178\u4e4b\u524d\u8fdb\u884c\u8131\u8721\u548c\u53bb\u77f3\u8721\u6b65\u9aa4\u3002\u4f20\u7edf\u65b9\u6cd5\u91c7\u7528\u591a\u6b21\u4e8c\u7532\u82ef\u548c\u4e59\u9187\u6d17\u6da4\uff0c\u5bf9\u73af\u5883\u6709\u5bb3\u4e14\u64cd\u4f5c\u7e41\u7410\u3002\u53ef\u4ee5\u8003\u8651\u81ea\u52a8\u5316\u66ff\u4ee3\u65b9\u6848\uff0c\u5982Applied Biosystems\u2122 AutoLys M\u7ba1\u548c\u76d6\u7528\u4e8e\u53bb\u77f3\u8721\uff0c\u5e76\u7ed3\u5408Applied Biosystems\u2122 MagMAX\u2122 FFPE DNA\/RNA\u5206\u79bb\u8bd5\u5242\u3002\u8fd9\u4e9b\u65b9\u6cd5\u91c7\u7528\u52a0\u70ed\u6b65\u9aa4\u548c\u86cb\u767d\u9176\u6d88\u5316\uff0c\u53d6\u4ee3\u6709\u5bb3\u5316\u5b66\u54c1\uff0c\u5927\u5927\u7b80\u5316\u4e86\u4f60\u7684\u5de5\u4f5c\u6d41\u7a0b\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b004cab642ef&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b004cab642ef\" class=\"aligncenter size-large wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/DNAE7-1024x447.png\" alt=\"Manual or semi-automated use of AutoLys M tubes and caps with FFPE sample preparation\" class=\"wp-image-4956\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\">\u56fe7 \u2013 AutoLys M \u7ba1\u548c\u76d6\u5b50\u7684\u624b\u52a8\u6216\u534a\u81ea\u52a8\u4f7f\u7528\u3002\u66f4\u591a\u8be6\u60c5\u8bf7\u53c2\u89c1\u672c\u5e94\u7528\u8bf4\u660e\uff1a<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/solvent-free-deparaffinization-method-ffpe-sample-prep-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e00\u79cd\u4fbf\u6377\u3001\u65e0\u6eb6\u5242\u7684FFPE\u6837\u672c\u8131\u8721\u65b9\u6cd5<\/a>\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u901a\u8fc7\u81ea\u52a8\u5316\u5c06\u4e0d\u540c\u5de5\u4f5c\u6d41\u7a0b\u7b80\u5316\u4e3a\u5355\u4e00\u89e3\u51b3\u65b9\u6848\">\u901a\u8fc7\u81ea\u52a8\u5316\u5c06\u4e0d\u540c\u5de5\u4f5c\u6d41\u7a0b\u7b80\u5316\u4e3a\u5355\u4e00\u89e3\u51b3\u65b9\u6848<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u53ef\u4ee5\u8003\u8651\u5728\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u4e4b\u95f4\u4f18\u5316\u5de5\u4f5c\u6d41\u7a0b\uff0c\u4ee5\u8282\u7701\u65f6\u95f4\u548c\u8d44\u6e90\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u624b\u5de5\u64cd\u4f5c\uff0c\u5f53\u60a8\u9700\u8981\u4ece\u5355\u4e00\u6837\u672c\u4e2d\u63d0\u53d6RNA\u3001DNA\u548c\u86cb\u767d\u8d28\u65f6\uff0c\u53ef\u8003\u8651\u4f7f\u7528TRI Reagent\u00ae\u3002\u5bf9\u4e8e\u81ea\u52a8\u5316\u6d41\u7a0b\uff0c\u53ef\u91c7\u7528\u5982MagMAX DNA Multi-Sample Ultra 2.0\u7b49\u78c1\u73e0\u6cd5\u8bd5\u5242\u76d2\uff0c\u901a\u8fc7\u5355\u4e00KingFisher\u534f\u8bae\u5904\u7406\u5168\u8840\u3001\u9aa8\u9ad3\u548c\u553e\u6db2\u7b49\u6837\u672c\u3002\u987a\u5e8f\u5206\u79bb\u8bd5\u5242\u76d2\uff0c\u5982Applied Biosystems\u2122 MagMAX Sequential DNA\/RNA Kit\uff0c\u53ef\u8ba9\u60a8\u4ece\u4e00\u4e2a\u6837\u672c\u4e2d\u540c\u65f6\u63d0\u53d6DNA\u548cRNA\u3002\u540c\u65f6\u4e5f\u8981\u8003\u8651\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u7684\u5236\u5907\u5dee\u5f02\u2014\u2014\u539f\u59cb\u7caa\u4fbf\u6837\u672c\u9700\u8981\u673a\u68b0\u5300\u6d46\u4ee5\u91ca\u653e\u7ec6\u80de\uff0c\u800c\u4fdd\u5b58\u4e8e\u57f9\u517b\u57fa\u4e2d\u7684\u7caa\u62ed\u5b50\u7528\u4e8e\u5fae\u751f\u7269DNA\u9274\u5b9a\u65f6\u53ef\u80fd\u4e0d\u9700\u8981\u6b64\u6b65\u9aa4\u3002\u7c7b\u4f3c\u7684\u4f18\u5316\u4e5f\u53ef\u5e94\u7528\u4e8e\u5c3f\u6db2\u3001\u5168\u8840\u3001\u553e\u6db2\u53ca\u5176\u4ed6\u6837\u672c\u7c7b\u578b\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6458\u8981\">\u6458\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9762\u5bf9\u4f17\u591aDNA\u63d0\u53d6\u65b9\u6848\uff0c\u4e86\u89e3\u5173\u952e\u53d8\u91cf\u5c06\u6709\u52a9\u4e8e\u60a8\u4e3a\u7279\u5b9a\u5e94\u7528\u9009\u62e9\u5408\u9002\u7684\u65b9\u6cd5\u3002\u8bf7\u53c2\u8003\u4ee5\u4e0b\u56e0\u7d20\uff0c\u4ee5\u6307\u5bfc\u60a8\u7684\u51b3\u7b56\uff0c\u5e76\u652f\u6301\u6d89\u53caDNA\u63d0\u53d6\u4f5c\u4e3a\u521d\u59cb\u6b65\u9aa4\u7684\u5404\u7c7b\u7814\u7a76\u5de5\u4f5c\u6d41\u7a0b\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6837\u672c\u4f53\u79ef\u8f93\u5165\u91cf<\/li>\n\n\n\n<li>\u5bf9\u6837\u672c\u6d53\u5ea6\/\u4ea7\u91cf\u7684\u8981\u6c42<\/li>\n\n\n\n<li>\u6837\u672c\u7c7b\u578b<\/li>\n\n\n\n<li>\u6837\u54c1\u901a\u91cf\u9700\u6c42<\/li>\n\n\n\n<li>\u76ee\u6807\u5206\u6790\u7269<\/li>\n\n\n\n<li>\u4e0b\u6e38\u5e94\u7528<\/li>\n\n\n\n<li>\u5bf9\u6d41\u7a0b\u7b80\u5316\u80fd\u529b\u7684\u9700\u6c42<\/li>\n<\/ul>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u66f4\u591adna\u63d0\u53d6\u5b66\u4e60\u4e0e\u8d44\u6e90\">\u66f4\u591aDNA\u63d0\u53d6\u5b66\u4e60\u4e0e\u8d44\u6e90<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u63a2\u7d22\uff1a<\/strong><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/genomic-dna-extraction.html\" target=\"_blank\" rel=\"noreferrer noopener\">\u57fa\u56e0\u7ec4DNA\u63d0\u53d6\u4e0e\u5206\u79bb<\/a><\/li>\n\n\n\n<li><strong>\u5b66\u4e60\uff1a<\/strong> <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis.html#na-extraction-methods\" target=\"_blank\" rel=\"noreferrer noopener\">DNA\u548cRNA\u63d0\u53d6\u4e0e\u7eaf\u5316<\/a><\/li>\n\n\n\n<li><strong>\u5b66\u4e60\uff1a<\/strong> <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/spin-column-purification.html\" target=\"_blank\" rel=\"noreferrer noopener\">\u79bb\u5fc3\u67f1\u63d0\u53d6\u6cd5<\/a><\/li>\n<\/ul>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-75 is-style-fill\"><a class=\"wp-block-button__link has-white-color has-text-color has-background has-link-color has-medium-font-size has-text-align-center has-custom-font-size wp-element-button\" href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis.html#na-extraction-methods\" style=\"border-radius:0px;background-color:#ee3134\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>\u63a2\u7d22DNA\u63d0\u53d6\u6280\u672f<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5b9e\u9a8c\u65b9\u6848\u548c\u5e94\u7528\u8bf4\u660e\">\u5b9e\u9a8c\u65b9\u6848\u548c\u5e94\u7528\u8bf4\u660e<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u64cd\u4f5c\u89c4\u7a0b\uff1a<\/strong> <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/references\/protocols\/nucleic-acid-purification-and-analysis\/dna-extraction-protocols\/extraction-of-dna-using-reagent.html\" target=\"_blank\" rel=\"noreferrer noopener\">\u4f7f\u7528DNAzol\u8bd5\u5242\u63d0\u53d6DNA<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong> <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Technical-Notes\/targeting-gastrointestinal-microbes-fecal-rectal-swab-specimens-tech-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u65e0\u9700\u73e0\u78e8\u5904\u7406\u4ece\u7caa\u4fbf\u548c\u76f4\u80a0\u62ed\u5b50\u6837\u672c\u4e2d\u9776\u5411\u80a0\u9053\u5fae\u751f\u7269<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/genetic-variance-across-sample-types-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e0d\u540c\u6837\u672c\u7c7b\u578b\u95f4\u9057\u4f20\u53d8\u5f02\u4e00\u81f4\u6027\u5206\u6790<\/a><\/li>\n\n\n\n<li><strong>\u6280\u672f\u8bf4\u660e\uff1a<\/strong> <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/references\/ambion-tech-support\/rna-isolation\/tech-notes\/rna--dna--and-protein-from-a-single-sample.html\" target=\"_blank\" rel=\"noreferrer noopener\">RNA\u3001DNA \u548c\u86cb\u767d\u8d28\u6765\u81ea\u540c\u4e00\u6837\u672c<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/solvent-free-deparaffinization-method-ffpe-sample-prep-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e00\u79cd\u4fbf\u6377\u3001\u65e0\u6eb6\u5242\u7684FFPE\u6837\u672c\u8131\u8721\u65b9\u6cd5<\/a><\/li>\n\n\n\n<li><strong>\u6d77\u62a5\uff1a<\/strong> <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/posters\/effects-swab-storage-nucleic-acid-poster.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u53e3\u8154\u62ed\u5b50\u50a8\u5b58\u6761\u4ef6\u5bf9\u5bbf\u4e3b\u548c\u5fae\u751f\u7269\u6838\u9178\u7a33\u5b9a\u6027\u53ca\u8d28\u91cf\u7684\u5f71\u54cd<\/a>&nbsp;<\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong> <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/cell-culture-quality-control-during-t-cell-expansion-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">T\u7ec6\u80de\u6269\u589e\u8fc7\u7a0b\u4e2d\u7684\u7ec6\u80de\u57f9\u517b\u8d28\u91cf\u63a7\u5236<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/human-leukocyte-antigen-testing-peripheral-blood-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u7528\u4e8e\u5916\u5468\u8840\u7684\u4eba\u7c7b\u767d\u7ec6\u80de\u6297\u539f\u68c0\u6d4b\u7684\u591a\u529f\u80fd\u89e3\u51b3\u65b9\u6848<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/comparative-study-saliva-collection-devices-axiom-human-genotyping-arrays-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u4f7f\u7528Axiom\u4eba\u7c7b\u57fa\u56e0\u5206\u578b\u82af\u7247\u5bf9\u553e\u6db2\u91c7\u96c6\u8bbe\u5907\u7684\u6bd4\u8f83\u7814\u7a76<\/a><\/li>\n\n\n\n<li><strong>\u5e94\u7528\u8bf4\u660e\uff1a<\/strong> <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/Application-Notes\/hematological-research-magmax-app-note.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u63a8\u8fdb\u8840\u6db2\u5b66\u7814\u7a76\uff1aMagMAX \u987a\u5e8f DNA\/RNA \u8bd5\u5242\u76d2<\/a>&nbsp;<\/li>\n<\/ul>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>##<\/em>&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u4ec5\u4f9b\u79d1\u7814\u4f7f\u7528\u3002\u4e0d\u5f97\u7528\u4e8e\u8bca\u65ad\u7a0b\u5e8f\u3002<\/em>&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u00a9 2025 Thermo Fisher Scientific Inc. \u4fdd\u7559\u6240\u6709\u6743\u5229\u3002\u9664\u975e\u53e6\u6709\u8bf4\u660e\uff0c\u6240\u6709\u5546\u6807\u5747\u4e3a Thermo Fisher Scientific \u53ca\u5176\u5b50\u516c\u53f8\u7684\u8d22\u4ea7\u3002<\/em>&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u9ad8\u6548\u7684DNA\u63d0\u53d6\u662f\u5168\u7403\u5206\u5b50\u751f\u7269\u5b66\u7814\u7a76\u3001\u8bca\u65ad\u548c\u6cd5\u533b\u5b66\u5e94\u7528\u7684\u57fa\u77f3\u3002\u65e0\u8bba\u60a8\u662f\u5728\u4e34\u5e8a\u5b9e\u9a8c\u5ba4\u5904\u7406\u8840\u6db2\u6837\u672c\u3001\u5728\u519c\u4e1a\u7814\u7a76\u4e2d\u5206<\/p>\n","protected":false},"author":1852,"featured_media":562,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[42],"division":[9],"class_list":["post-561","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-dna","division-bid","entry"],"_selected_authors":[968],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b\" \/>\n<meta property=\"og:description\" content=\"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-02T03:49:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-09T05:50:20+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"887\" \/>\n\t<meta property=\"og:image:height\" content=\"579\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b\",\"datePublished\":\"2026-03-02T03:49:27+00:00\",\"dateModified\":\"2026-03-09T05:50:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/\"},\"wordCount\":202,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/DNAE0.jpg\",\"keywords\":[\"DNA\u63d0\u53d6\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#respond\"]}],\"accessibilityFeature\":[\"tableOfContents\"]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/\",\"name\":\"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/DNAE0.jpg\",\"datePublished\":\"2026-03-02T03:49:27+00:00\",\"dateModified\":\"2026-03-09T05:50:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/DNAE0.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/02\\\/DNAE0.jpg\",\"width\":887,\"height\":579},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/dna-extraction-guide-mastering-7-essential-sample-types\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/","og_locale":"zh_CN","og_type":"article","og_title":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b","og_description":"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-02T03:49:27+00:00","article_modified_time":"2026-03-09T05:50:20+00:00","og_image":[{"width":887,"height":579,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b","datePublished":"2026-03-02T03:49:27+00:00","dateModified":"2026-03-09T05:50:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/"},"wordCount":202,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg","keywords":["DNA\u63d0\u53d6"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#respond"]}],"accessibilityFeature":["tableOfContents"]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/","name":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg","datePublished":"2026-03-02T03:49:27+00:00","dateModified":"2026-03-09T05:50:20+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u63a2\u7d22DNA\u7eaf\u5316\u7684\u91cd\u8981\u6027\uff0c\u5e76\u4e86\u89e3\u9488\u5bf9\u4e0d\u540c\u6837\u672c\u7c7b\u578b\uff08\u5305\u62ec\u4f53\u6db2\u3001\u7ec4\u7ec7\u3001\u690d\u7269\u3001FFPE\u7b49\uff09\u7684\u5b9e\u7528\u5efa\u8bae\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg","width":887,"height":579},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/dna-extraction-guide-mastering-7-essential-sample-types\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"DNA\u63d0\u53d6\u6307\u5357\uff1a\u638c\u63e17\u79cd\u6837\u672c\u7c7b\u578b"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":42,"label":"DNA\u63d0\u53d6"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/DNAE0.jpg",760,496,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":42,"name":"DNA\u63d0\u53d6","slug":"dna%e6%8f%90%e5%8f%96","term_group":0,"term_taxonomy_id":42,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=561"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/561\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/562"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=561"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}