{"id":649,"date":"2026-03-05T01:41:00","date_gmt":"2026-03-05T01:41:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=649"},"modified":"2026-04-30T06:40:21","modified_gmt":"2026-04-30T06:40:21","slug":"exploring-advanced-characterization-techniques-for-solid-state-battery-innovation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/","title":{"rendered":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/promo\/electron-microscopy\/resource-library.html?icid=cn-blog-msd\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-1024x176.jpg\" alt=\"\" class=\"wp-image-1738\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/Blog-\u7535\u955cbanner-1-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7b80\u4ecb\"><strong>\u7b80\u4ecb<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u56fa\u6001\u7535\u6c60\u7684\u5f00\u53d1\u8fc7\u7a0b\u4e2d\uff0c\u5148\u8fdb\u7684\u8868\u5f81\u6280\u672f\u5bf9\u4e8e\u7406\u89e3\u6240\u6d89\u53ca\u7684\u6750\u6599\u81f3\u5173\u91cd\u8981\u3002\u8fd9\u4e9b\u6280\u672f\u80fd\u591f\u6df1\u5165\u63ed\u793a\u7535\u6c60\u7ec4\u4ef6\u7684\u7ed3\u6784\u548c\u6027\u80fd\uff0c\u4e3a\u66f4\u9ad8\u6548\u3001\u66f4\u5b89\u5168\u7684\u50a8\u80fd\u89e3\u51b3\u65b9\u6848\u94fa\u5e73\u9053\u8def\u3002\u672c\u7cfb\u5217\u7684\u8fd9\u4e00\u90e8\u5206\u5c06\u63a2\u8ba8\u51e0\u79cd\u6b63\u5728\u9769\u65b0\u56fa\u6001\u7535\u6c60\u7814\u7a76\u7684\u524d\u6cbf\u8868\u5f81\u65b9\u6cd5\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7535\u5b50\u663e\u5fae\u955c\"><strong>\u7535\u5b50\u663e\u5fae\u955c<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\uff1aSEM\u662f\u4e00\u79cd\u5f3a\u5927\u7684\u5de5\u5177\uff0c\u53ef\u7528\u4e8e\u68c0\u67e5\u7535\u6c60\u6750\u6599\u5728\u5fae\u7c73\u5c3a\u5ea6\u4e0a\u7684\u8868\u9762\u5f62\u8c8c\u548c\u7ed3\u6784\u7ec6\u8282\u3002\u901a\u8fc7\u7528\u7535\u5b50\u8f70\u51fb\u6837\u54c1\u5e76\u6d4b\u91cf\u53d1\u5c04\u51fa\u7684\u4e8c\u6b21\u6216\u80cc\u6563\u5c04\u7535\u5b50\uff0cSEM\u80fd\u591f\u751f\u6210\u9ad8\u5206\u8fa8\u7387\u56fe\u50cf\uff0c\u63ed\u793a\u8868\u9762\u7684\u7eb9\u7406\u548c\u6210\u5206\u3002\u7814\u7a76\u4eba\u5458\u5229\u7528SEM\u5bf9\u4e0b\u4e00\u4ee3\u7535\u6c60\u5f00\u53d1\u4e2d\u4f7f\u7528\u7684\u6750\u6599\u8fdb\u884c\u8868\u5f81\uff0c\u4f8b\u5982\u89c2\u5bdf\u548c\u5206\u6790\u7528\u4e8e\u6b63\u6781\u6d3b\u6027\u6750\u6599\u4e0a\u7684\u8584\u6d82\u5c42\u3002\uff08\u5982\u4e0b\u56fe1\u6240\u793a\uff0c<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/electron-microscopy\/products\/scanning-electron-microscopes\/apreo-sem.html?icid=CAD_blog_materials_2025June\">\u8d5b\u9ed8\u98de\u4e16\u5c14\u79d1\u5b66\u516c\u53f8\u7684Apreo ChemiSEM\u2122 \u4eea\u5668<\/a>\u88ab\u7528\u4e8e\u4ee5\u6781\u4f4e\u7740\u9646\u7535\u538b\u68c0\u6d4bNMC\u6b63\u6781\u9897\u7c92\u4e0a\u7684\u8d85\u8584\u6d82\u5c42\u3002\uff09\n\n<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2025\/06\/BatteryCharacterization_1.jpg\" alt=\"SEM image\" class=\"wp-image-14535\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em><em>\u56fe1\uff1aNMC\u6b63\u6781\u9897\u7c92\u7684600 eV\u80cc\u6563\u5c04\u7535\u5b50\uff08BSE\uff09\u56fe\u50cf\u3002<\/em><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ChemiSEM\u6280\u672f\uff1a<\/strong>\u8fd9\u79cd\u521b\u65b0\u65b9\u6cd5\u901a\u8fc7\u63d0\u4f9b\u66f4\u5feb\u901f\u3001\u66f4\u51c6\u786e\u4e14\u66f4\u7b80\u5316\u7684EDS\u6d41\u7a0b\uff0c\u63d0\u5347\u4e86\u4f20\u7edfSEM\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u7684\u5e94\u7528\u3002\u5b83\u91c7\u7528\u5b9e\u65f6\u5f69\u8272\u6210\u50cf\u7a81\u51fa\u663e\u793a\u5316\u5b66\u5143\u7d20\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u8fc5\u901f\u8bc6\u522b\u548c\u533a\u5206\u6837\u54c1\u4e2d\u7684\u5404\u79cd\u6750\u6599\uff0c\u65e0\u9700\u989d\u5916\u5206\u6790\u6280\u672f\u5373\u53ef\u5373\u65f6\u83b7\u5f97\u6750\u6599\u7ec4\u6210\u4fe1\u606f\u3002\u8fd9\u5f97\u76ca\u4e8eChemiSEM\u5b8c\u5168\u96c6\u6210\u4e8eSEM\u4e2d\uff0c\u5e76\u4e14<em>\u59cb\u7ec8\u5f00\u542f<\/em>.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/brochures\/sem-lithium-battery-research-en-br0147.pdf?icid=CAD_blog_materials_2025June\">\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u7535\u6c60\u79d1\u5b66\u7684SEM\u6280\u672f<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>2. \u53cc\u675f\u805a\u7126\u79bb\u5b50\u675f\uff08FIB\uff09-\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u7cfb\u7edf\uff1a<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>FIB\u7cfb\u7edf\u4e0eSEM\u96c6\u6210\uff0c\u5f62\u6210\u53cc\u675f\u7cfb\u7edf\uff0c\u5b9e\u73b0\u6210\u50cf\u548c\u6750\u6599\u64cd\u4f5c\u3002\u8fd9\u4e9b\u7cfb\u7edf\u7279\u522b\u9002\u7528\u4e8e\u5feb\u901f\u3001\u7279\u5b9a\u4f4d\u7f6e\u7684\u622a\u9762\u6837\u54c1\u5236\u5907\u3001\u4e09\u7ef4\u6750\u6599\u8868\u5f81\u4ee5\u53caS\/TEM\u8584\u7247\u5236\u5907\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u7814\u7a76\u7535\u6c60\u7ec4\u4ef6\u7684\u5185\u90e8\u7ed3\u6784\u3002\u4e0b\u65b9\u56fe2\u5c55\u793a\u4e86\u5982\u4f55\u5728\u53cc\u675f\u7cfb\u7edf\u4e2d\u51c6\u5907\u622a\u9762\uff0c\u4ee5\u53ca\u7ecf\u8fc7\u622a\u9762\u5236\u5907\u540e\u7684\u56fa\u6001\u7535\u6c60\u6b63\u6781\u4ee3\u8868\u6027\u6837\u54c1\u3002\u5229\u7528SEM\uff0c\u53ef\u4ee5\u8f7b\u677e\u89c2\u5bdf\u6837\u54c1\u5185\u90e8\u7ed3\u6784\uff0c\u5bf9\u5c42\u548c\u9897\u7c92\u8fdb\u884c\u6d4b\u91cf\uff0c\u5e76\u6839\u636e\u9700\u8981\u8fdb\u884c\u5206\u6790\u8868\u5f81\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2025\/06\/BatteryCharacterization_2.jpg\" alt=\"SEM in a DualBeam example\" class=\"wp-image-14536\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em><em>\u56fe2\uff1a2a \u2013 \u6837\u54c1\u76f8\u5bf9\u4e8e\u53cc\u675f\u7cfb\u7edf\u4e2d\u7684FIB\u548cSEM\u793a\u610f\u56fe\uff0c2b \u2013 \u7528PFIB\u5236\u5907\u7684\u56fa\u6001\u7535\u6c60\u6b63\u6781\u622a\u9762\u3002<\/em><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7b49\u79bb\u5b50\u4f53FIB\uff1a<\/strong>\u4e3b\u8981\u5730\uff0c\u7b49\u79bb\u5b50\u4f53FIB\u4f7f\u7528\u60f0\u6027\u7a00\u6709\u6c14\u4f53\u5982\u6c19\u6216\u6c29\u6765\u68c0\u67e5\u66f4\u5927\u4f53\u79ef\u7684\u6750\u6599\uff0c\u975e\u5e38\u9002\u5408\u7814\u7a76\u7535\u6c60\u5185\u7684\u5927\u5757\u6027\u8d28\u548c\u5927\u5c3a\u5ea6\u7279\u5f81\u3002\u60f0\u6027\u6c14\u4f53\u4f5c\u4e3a\u4e3b\u8981\u79bb\u5b50\u6e90\u7684\u53e6\u4e00\u4e2a\u4f18\u70b9\u662f\uff0c\u4e0e\u542b\u9502\u6750\u6599\u4e4b\u95f4\u51e0\u4e4e\u6ca1\u6709\u79bb\u5b50\/\u6837\u54c1\u76f8\u4e92\u4f5c\u7528\u3002<\/li>\n\n\n\n<li><strong>\u9553FIB\uff1a<\/strong>\u9553FIB\u7528\u4e8e\u66f4\u5c0f\u5c3a\u5ea6\u7684\u8be6\u7ec6\u5206\u6790\uff0c\u80fd\u591f\u5bf9\u7cbe\u7ec6\u7ed3\u6784\u548c\u754c\u9762\u8fdb\u884c\u9ad8\u5206\u8fa8\u7387\u6210\u50cf\u3002\u7136\u800c\uff0c\u4f7f\u7528\u9553FIB\u53ef\u80fd\u4f1a\u5bf9\u542b\u9502\u7ed3\u6784\u4ea7\u751f\u5fae\u5999\u7684\u53d8\u5316\uff0c\u56e0\u4e3a\u5728\u5ba4\u6e29\u4e0b\u9553\u4e0e\u9502\u4e4b\u95f4\u5b58\u5728\u5f3a\u70c8\u7684\u76f8\u4e92\u4f5c\u7528\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/brochures\/BR0172-sbd-battery-ebook-en.pdf?icid=CAD_blog_materials_2025June\">\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u7535\u6c60\u79d1\u5b66\u4e2dDualBeam\u6280\u672f\u7684\u4fe1\u606f<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>3. \u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\uff1a<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>TEM\u53ef\u5728\u4e9a\u7eb3\u7c73\u7ea7\u522b\u63d0\u4f9b\u9ad8\u5206\u8fa8\u7387\u8868\u5f81\uff0c\u4e3a\u63ed\u793a\u539f\u5b50\u7ea7\u884c\u4e3a\u63d0\u4f9b\u4fe1\u606f\u3002\u901a\u8fc7TEM\uff0c\u79d1\u5b66\u5bb6\u548c\u5de5\u7a0b\u5e08\u53ef\u4ee5\u6df1\u5165\u7814\u7a76\u6750\u6599\u7ed3\u6784\u7684\u590d\u6742\u7ec6\u8282\uff0c\u5982\u539f\u5b50\u6392\u5217\u548c\u6676\u4f53\u7ed3\u6784\uff0c\u4ece\u800c\u83b7\u5f97\u5176\u4ed6\u6280\u672f\u65e0\u6cd5\u83b7\u53d6\u7684\u7ed3\u6784\u4e0e\u529f\u80fd\u5173\u7cfb\u65b9\u9762\u7684\u89c1\u89e3\u3002<\/li>\n\n\n\n<li>\u5bf9\u4e8e\u7535\u6c60\u5e94\u7528\uff0cTEM\u6280\u672f\u5982\u9ad8\u5206\u8fa8\u7387\u6210\u50cf\u3001\u7535\u5b50\u884d\u5c04\u3001EDS\u548cEELS\uff0c\u53ef\u4ee5\u4e3a\u7535\u6c60\u7ec4\u4ef6\u7684\u5f62\u8c8c\u3001\u6676\u4f53\u7ed3\u6784\u53ca\u5316\u5b66\u4fe1\u606f\u63d0\u4f9b\u6709\u4ef7\u503c\u7684\u89c1\u89e3\u3002\u5b83\u975e\u5e38\u9002\u5408\u5bf9\u7535\u6c60\u7814\u7a76\u4e2d\u5e38\u89c1\u7684\u675f\u654f\u611f\u6750\u6599\uff08\u5982\u56fa\u6001\u7535\u89e3\u8d28\u754c\u9762SEI\uff09\u8fdb\u884c\u7eb3\u7c73\u5c3a\u5ea6\u8868\u5f81\u3002\u89e3\u6790SEI\u7684\u7ec4\u6210\u548c\u7ed3\u6784\u5bf9\u4e8e\u7406\u89e3\u9502\u79bb\u5b50\u5982\u4f55\u8fdb\u51fa\u7535\u6781\u81f3\u5173\u91cd\u8981\uff0c\u8fd9\u6709\u52a9\u4e8e\u89e3\u91ca\u7535\u6c60\u5faa\u73af\u8fc7\u7a0b\u4e2d\u5bb9\u91cf\u4fdd\u6301\u7387\u4e0b\u964d\u7684\u539f\u56e0\u3002\u8fd9\u4e9b\u89c1\u89e3\u5bf9\u4e8e\u5f00\u53d1\u4e0b\u4e00\u4ee3\u7535\u6c60\u4ee5\u53ca\u6df1\u5165\u7406\u89e3\u8001\u5316\u4e0e\u5931\u6548\u673a\u5236\u5177\u6709\u91cd\u8981\u610f\u4e49\u3002\u4e0b\u56fe3\u5c55\u793a\u4e86\u5982\u4f55\u5229\u7528TEM\u7814\u7a76\u9502\u91d1\u5c5e\u6837\u54c1\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2025\/06\/BatteryCharacterization_3.jpg\" alt=\"low magnification image of Li-metal at 200 keV with the HAADF detector\" class=\"wp-image-14537\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em><em>\u56fe3\uff1a3a \u2013 \u4f7f\u7528HAADF\u63a2\u6d4b\u5668\u5728200 keV\u4e0b\u83b7\u5f97\u7684\u9502\u91d1\u5c5e\u4f4e\u500d\u56fe\u50cf\uff1b3b \u2013 \u9502\u6676\u683c\u7ed3\u6784\u7684\u9ad8\u5206\u8fa8\u7387TEM\u56fe\u50cf\u3002<\/em><\/em><\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/industrial\/cryo-and-in-situ-em-diagnosis-guided-design-of-rechargeable-battery-materials-for-better-batteries.html?icid=CAD_blog_materials_2025June\">\u89c2\u770b\u6211\u4eec\u5173\u4e8e\u901a\u8fc7TEM\u8868\u5f81SEI\u5c42\u7684\u7f51\u7edc\u7814\u8ba8\u4f1a<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-x\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31-xps\"><strong>X\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">X\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u662f\u4e00\u79cd\u8868\u9762\u5206\u6790\u6280\u672f\uff0c\u53ef\u4e3a\u6837\u54c1\u6700\u8868\u5c42\u63d0\u4f9b\u5b9a\u91cf\u5143\u7d20\u3001\u7535\u5b50\u6001\u3001\u5316\u5b66\u72b6\u6001\u53ca\u952e\u5408\u4fe1\u606f\u3002\u5728\u7535\u6c60\u884c\u4e1a\u4e2d\uff0c\u5b83\u7279\u522b\u9002\u7528\u4e8e\u7814\u7a76\u8868\u9762\u73b0\u8c61\uff0c\u5982\u754c\u9762\u53cd\u5e94\u3001\u8868\u9762\u6c61\u67d3\uff0c\u5c24\u5176\u662f\u5728\u9610\u660eSEI\u5f62\u6210\u673a\u5236\u65b9\u9762\u3002\u4f8b\u5982\uff0c\u53ef\u4ee5\u7814\u7a76\u9502\u79bb\u5b50\u7535\u6c60\u6b63\u8d1f\u6781\u6750\u6599\uff0c\u4ee5\u786e\u8ba4\u5faa\u73af\u540e\u6210\u5206\u53d8\u5316\uff0c\u4e86\u89e3\u7535\u6781\u7ec4\u5206\u5316\u5b66\u6027\u8d28\u53d8\u5316\uff0c\u5e76\u786e\u5b9a\u56fa\u6001\u7535\u89e3\u8d28\u754c\u9762\uff08SEI\uff09\u5c42\u968f\u53d1\u5c55\u8fc7\u7a0b\u4e2d\u7684\u6df1\u5ea6\u53d8\u5316\u3002XPS\u5df2\u88ab\u8bc1\u660e\u5728\u7814\u7a76\u77f3\u58a8\u8d1f\u6781\u6750\u6599\u8868\u9762\u9884\u5904\u7406\u4ee5\u663e\u8457\u51cf\u7f13\u5145\u7535\u8fc7\u7a0b\u4e2d\u4e0d\u53ef\u9006\u635f\u8017\u65b9\u9762\u975e\u5e38\u6709\u7528\u3002\u4e0b\u56fe4\u5c55\u793a\u4e86\u5982\u4f55\u5229\u7528XPS\u663e\u793a\u5faa\u73af\u540e\u4e0e\u539f\u59cb\u6b63\u6781\u6d3b\u6027\u6750\u6599\u4e2d\u7684\u5316\u5b66\u53d8\u5316\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2025\/06\/BatteryCharacterization_4.jpg\" alt=\": Survey spectra from pristine cathode (blue) and cycled cathode (red) samples.\" class=\"wp-image-14538\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em><em>\u56fe4\uff1a\u539f\u59cb\u6b63\u6781\uff08\u84dd\u8272\uff09\u548c\u5faa\u73af\u540e\u6b63\u6781\uff08\u7ea2\u8272\uff09\u6837\u54c1\u7684\u8c03\u67e5\u5149\u8c31\u3002<\/em><\/em><\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/brochures\/advancing-battery-technology-br0194-en.pdf?icid=CAD_blog_materials_2025June\">\u4e86\u89e3\u66f4\u591a\u5173\u4e8e\u7528\u4e8e\u7535\u6c60\u79d1\u5b66\u7684XPS\u6280\u672f<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u56fe\u50cf\u5206\u6790\u8f6f\u4ef6\"><strong>\u56fe\u50cf\u5206\u6790\u8f6f\u4ef6<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>1. \u5c06\u539f\u59cb\u6570\u636e\u8f6c\u5316\u4e3a\u6d1e\u5bdf\u529b\uff1a<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5148\u8fdb\u7684\u6210\u50cf\u6280\u672f\u4f1a\u4ea7\u751f\u5927\u91cf\u6570\u636e\uff0c\u5fc5\u987b\u8fdb\u884c\u5206\u6790\u4ee5\u63d0\u53d6\u6709\u610f\u4e49\u7684\u89c1\u89e3\u3002\u56fe\u50cf\u5206\u6790\u8f6f\u4ef6\u7528\u4e8e\u5904\u7406\u548c\u89e3\u91ca\u8fd9\u4e9b\u6570\u636e\uff0c\u63d0\u4f9b\u5b9a\u91cf\u6d4b\u91cf\u548c\u53ef\u89c6\u5316\u7ed3\u679c\uff0c\u4ece\u800c\u589e\u5f3a\u5bf9\u6750\u6599\u7279\u6027\u7684\u7406\u89e3\u3002<\/li>\n\n\n\n<li><strong>3D\u6210\u50cf\uff1a<\/strong>\u67d0\u4e9b\u8f6f\u4ef6\uff08\u5982Avizo\uff09\u652f\u6301\u4e8c\u7ef4\u548c\u4e09\u7ef4\u6210\u50cf\uff0c\u80fd\u591f\u5168\u9762\u5c55\u793a\u6750\u6599\u7ed3\u6784\u3002\u8fd9\u4e00\u529f\u80fd\u5bf9\u4e8e\u8bc4\u4f30\u7535\u6c60\u5236\u9020\u5de5\u827a\u8d28\u91cf\u3001\u7814\u7a76\u8001\u5316\u73b0\u8c61\u4ee5\u53ca\u7406\u89e3\u7535\u6781\u6750\u6599\u7684\u8fde\u901a\u6027\u548c\u66f2\u6298\u5ea6\u81f3\u5173\u91cd\u8981\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>2. \u5b9a\u91cf\u5206\u6790\uff1a<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u67d0\u4e9b\u8f6f\u4ef6\uff0c\u4f8b\u5982\uff1a<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/electron-microscopy\/products\/software-em-3d-vis\/avizo-software\/avizo-trueput-software-battery-quality-control.html?icid=CAD_blog_materials_2025June\">Avizo Trueput\u2122<\/a> \u5141\u8bb8\u7814\u7a76\u4eba\u5458\u8bc6\u522b\u548c\u6d4b\u91cf\u7535\u6781\u6750\u6599\u53ca\u6574\u4e2a\u7535\u6c60\u4e2d\u7684\u590d\u6742\u7279\u5f81\u3002\u901a\u8fc7\u91cf\u5316\u5b54\u5f84\u3001\u5206\u5e03\u548c\u8fde\u901a\u6027\u7b49\u65b9\u9762\uff0c\u7814\u7a76\u4eba\u5458\u53ef\u4ee5\u5c06\u7ed3\u6784\u7279\u6027\u4e0e\u6027\u80fd\u6307\u6807\u76f8\u5173\u8054\uff0c\u4ece\u800c\u6307\u5bfc\u7535\u6c60\u8bbe\u8ba1\u7684\u6539\u8fdb\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2025\/06\/BatteryCharacterization_5.jpg\" alt=\"Example of NMC cathode cross-section segmented for particle cracking \" class=\"wp-image-14539\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em><em>\u56fe5\uff1aAvizo Trueput\u5bf9NMC\u6b63\u6781\u6a2a\u622a\u9762\u8fdb\u884c\u9897\u7c92\u88c2\u7eb9\u5206\u5272\u7684\u793a\u4f8b\u3002<\/em><\/em><\/p>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><strong><strong>3. \u9884\u6d4b\u5efa\u6a21\uff1a<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9664\u4e86\u56fe\u50cf\u5206\u6790\u5916\uff0c\u4e00\u4e9b\u8f6f\u4ef6\u8fd8\u53ef\u7528\u4e8e\u9884\u6d4b\u5efa\u6a21\u3002\u901a\u8fc7\u6a21\u62df\u6750\u6599\u5728\u4e0d\u540c\u6761\u4ef6\u4e0b\u7684\u884c\u4e3a\uff0c\u7814\u7a76\u4eba\u5458\u80fd\u591f\u9884\u6d4b\u7ed3\u6784\u6216\u6210\u5206\u53d8\u5316\u5982\u4f55\u5f71\u54cd\u7535\u6c60\u6027\u80fd\u3002\u8fd9\u4e00\u80fd\u529b\u5bf9\u4e8e\u4f18\u5316\u6750\u6599\u5e76\u52a0\u901f\u4e0b\u4e00\u4ee3\u7535\u6c60\u7684\u5f00\u53d1\u5177\u6709\u4e0d\u53ef\u4f30\u91cf\u7684\u4ef7\u503c\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/electron-microscopy\/products\/software-em-3d-vis\/avizo-software\/batteries.html?icid=CAD_blog_materials_2025June#resources\">\u4e86\u89e3\u66f4\u591a\u5173\u4e8eAvizo\u5728\u7535\u6c60\u79d1\u5b66\u9886\u57df\u7684\u89e3\u51b3\u65b9\u6848<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7ed3\u8bba\u4e0e\u8bf4\u660e\"><strong>\u7ed3\u8bba\u4e0e\u8bf4\u660e<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5148\u8fdb\u8868\u5f81\u6280\u672f\u6b63\u5728\u9769\u65b0\u56fa\u6001\u7535\u6c60\u7814\u7a76\uff0c\u4e3a\u6750\u6599\u53ca\u5176\u5728\u7535\u6c60\u5185\u90e8\u7684\u76f8\u4e92\u4f5c\u7528\u63d0\u4f9b\u4e86\u8be6\u7ec6\u6d1e\u5bdf\u3002SEM\u3001TEM\u3001FIB\u548cXPS\u7b49\u6280\u672f\u7ed3\u5408\u5148\u8fdb\u56fe\u50cf\u5206\u6790\u8f6f\u4ef6\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u4f18\u5316\u7535\u6c60\u6750\u6599\uff0c\u4ee5\u63d0\u5347\u6027\u80fd\u548c\u5b89\u5168\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/industrial\/green-energy-battery-join-our-community-registration-form.html?erpType=Global_E1\">\u52a0\u5165\u6211\u4eec\u7684\u7535\u6c60\u793e\u533a<\/a>\u4e86\u89e3\u66f4\u591a\u5e76\u53ca\u65f6\u638c\u63e1\u6700\u65b0Thermo Scientific\u7535\u6c60\u89e3\u51b3\u65b9\u6848\u4e0e\u6280\u672f\u52a8\u6001\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><em>\u7279\u522b\u611f\u8c22Dr. Chengge Jiao\u3001Dr. Eric Goergen\u3001Dr. Lin Jiang\u3001Dr. Letian Li\u3001Dr. Zhao Liu\u3001Dr. Maria Meledina\u3001Dr. Tim Nunney \u548c Dr. Luigi Raspolini \u5bf9\u672c\u6587\u505a\u51fa\u7684\u8d21\u732e\u3002<\/em><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7b80\u4ecb \u5728\u56fa\u6001\u7535\u6c60\u7684\u5f00\u53d1\u8fc7\u7a0b\u4e2d\uff0c\u5148\u8fdb\u7684\u8868\u5f81\u6280\u672f\u5bf9\u4e8e\u7406\u89e3\u6240\u6d89\u53ca\u7684\u6750\u6599\u81f3\u5173\u91cd\u8981\u3002\u8fd9\u4e9b\u6280\u672f\u80fd\u591f\u6df1\u5165\u63ed\u793a\u7535\u6c60\u7ec4\u4ef6\u7684\u7ed3\u6784\u548c<\/p>\n","protected":false},"author":1852,"featured_media":650,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[51,7],"tags":[68,67,20],"division":[6],"class_list":["post-649","post","type-post","status-publish","format-standard","has-post-thumbnail","category-51","category-7","tag-xps","tag-67","tag-20","division-msd","entry"],"_selected_authors":[808],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f\" \/>\n<meta property=\"og:description\" content=\"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-05T01:41:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-30T06:40:21+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f\",\"datePublished\":\"2026-03-05T01:41:00+00:00\",\"dateModified\":\"2026-04-30T06:40:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/\"},\"wordCount\":98,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg\",\"keywords\":[\"XPS\",\"\u56fa\u6001\u7535\u6c60\",\"\u7535\u955c\"],\"articleSection\":[\"\u6750\u6599\u79d1\u5b66\",\"\u7535\u5b50\u663e\u5fae\u955c\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/\",\"name\":\"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg\",\"datePublished\":\"2026-03-05T01:41:00+00:00\",\"dateModified\":\"2026-04-30T06:40:21+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/","og_locale":"zh_CN","og_type":"article","og_title":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f","og_description":"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-05T01:41:00+00:00","article_modified_time":"2026-04-30T06:40:21+00:00","og_image":[{"width":2560,"height":1920,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f","datePublished":"2026-03-05T01:41:00+00:00","dateModified":"2026-04-30T06:40:21+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/"},"wordCount":98,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg","keywords":["XPS","\u56fa\u6001\u7535\u6c60","\u7535\u955c"],"articleSection":["\u6750\u6599\u79d1\u5b66","\u7535\u5b50\u663e\u5fae\u955c"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/","name":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg","datePublished":"2026-03-05T01:41:00+00:00","dateModified":"2026-04-30T06:40:21+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u63a2\u7d22\u5728\u56fa\u6001\u7535\u6c60\u7814\u7a76\u4e2d\u4f7f\u7528\u7684\u5148\u8fdb\u8868\u5f81\u6280\u672f\uff0c\u5982\u626b\u63cf\u7535\u5b50\u663e\u5fae\u955c\uff08SEM\uff09\u3001\u53cc\u675f\u7cfb\u7edf\uff08DualBeam\uff09\u3001\u900f\u5c04\u7535\u5b50\u663e\u5fae\u955c\uff08TEM\uff09\u548cX\u5c04\u7ebf\u5149\u7535\u5b50\u80fd\u8c31\uff08XPS\uff09\u3002\u4e86\u89e3\u8fd9\u4e9b\u5de5\u5177\u5982\u4f55\u4e3a\u6750\u6599\u6027\u80fd\u63d0\u4f9b\u5173\u952e\u6d1e\u5bdf\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1.jpg","width":2560,"height":1920},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u56fa\u6001\u7535\u6c60\u5148\u8fdb\u8868\u5f81\u6280\u672f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":51,"label":"\u6750\u6599\u79d1\u5b66"},{"value":7,"label":"\u7535\u5b50\u663e\u5fae\u955c"}],"post_tag":[{"value":68,"label":"XPS"},{"value":67,"label":"\u56fa\u6001\u7535\u6c60"},{"value":20,"label":"\u7535\u955c"}],"division":[{"value":6,"label":"MSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1444834086_solidstatebatteryenergy-scaled-1-1024x768.jpg",760,570,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":51,"name":"\u6750\u6599\u79d1\u5b66","slug":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":51,"taxonomy":"category","description":"","parent":0,"count":30,"filter":"raw","meta":[],"cat_ID":51,"category_count":30,"category_description":"","cat_name":"\u6750\u6599\u79d1\u5b66","category_nicename":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","category_parent":0},{"term_id":7,"name":"\u7535\u5b50\u663e\u5fae\u955c","slug":"%e7%94%b5%e5%ad%90%e6%98%be%e5%be%ae%e9%95%9c","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":28,"filter":"raw","meta":[],"cat_ID":7,"category_count":28,"category_description":"","cat_name":"\u7535\u5b50\u663e\u5fae\u955c","category_nicename":"%e7%94%b5%e5%ad%90%e6%98%be%e5%be%ae%e9%95%9c","category_parent":0}],"tag_info":[{"term_id":68,"name":"XPS","slug":"xps","term_group":0,"term_taxonomy_id":68,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]},{"term_id":67,"name":"\u56fa\u6001\u7535\u6c60","slug":"%e5%9b%ba%e6%80%81%e7%94%b5%e6%b1%a0","term_group":0,"term_taxonomy_id":67,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":20,"name":"\u7535\u955c","slug":"%e7%94%b5%e9%95%9c","term_group":0,"term_taxonomy_id":20,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=649"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/649\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/650"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=649"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=649"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=649"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}