{"id":666,"date":"2026-03-10T02:34:48","date_gmt":"2026-03-10T02:34:48","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=666"},"modified":"2026-03-10T02:34:50","modified_gmt":"2026-03-10T02:34:50","slug":"the-polymer-development-process","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/the-polymer-development-process\/","title":{"rendered":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5f53\u6750\u6599\u79d1\u5b66\u5bb6\u5bfb\u6c42\u5f00\u53d1\u65b0\u7684\u8f7b\u8d28\u3001\u67d4\u6027\u3001\u7ecf\u6d4e\u9ad8\u6548\u6216\u5176\u4ed6\u66f4\u4f18\u89e3\u51b3\u65b9\u6848\u65f6\uff0c\u4ed6\u4eec\u7ecf\u5e38\u4f1a\u5173\u6ce8\u805a\u5408\u7269\u3002\u5bf9\u4e8e\u98df\u54c1\u5305\u88c5\u3001\u6c7d\u8f66\u96f6\u90e8\u4ef6\u3001\u5efa\u7b51\u6750\u6599\u3001\u7535\u5b50\u4ea7\u54c1\u3001\u533b\u7597\u4fdd\u5065\u548c\u533b\u5b66\u5e94\u7528\u3001\u7eba\u7ec7\u54c1\u548c\u670d\u88c5\u3001\u822a\u7a7a\u822a\u5929\u4e0e\u56fd\u9632\u3001\u6e05\u6d01\u80fd\u6e90\u4ee5\u53ca\u5404\u79cd\u5176\u4ed6\u4ea7\u54c1\uff0c\u7814\u7a76\u4eba\u5458\u901a\u5e38\u4f1a\u9009\u62e9<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/materials-science-research\/polymer-analysis.html?icid=CAD_blog_materials_2024Sept\">\u805a\u5408\u7269\u5206\u6790<\/a>\u4e0e\u5f00\u53d1\u6d41\u7a0b\u3002\u8bf8\u5982<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/o\/a\/extrusion-possibilities-new-polymer-development.html?icid=CAD_blog_materials_2024Sept\">\u6324\u51fa<\/a>\u548c\u6df7\u70bc\u7b49\u5de5\u827a\u53ef\u4ee5\u5e2e\u52a9\u5f00\u53d1\u5177\u6709\u7279\u5b9a\u6240\u9700\u6027\u80fd\u7684\u65b0\u578b\u805a\u5408\u7269\u6750\u6599\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u805a\u5408\u7269\u7684\u5236\u9020\u8fc7\u7a0b\"><strong>\u805a\u5408\u7269\u7684\u5236\u9020\u8fc7\u7a0b<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u805a\u5408\u7269\u662f\u7531\u79f0\u4e3a\u5355\u4f53\u7684\u91cd\u590d\u4e9a\u5355\u4f4d\u7ec4\u6210\u7684\u5927\u5206\u5b50\u3002\u5b83\u4eec\u662f\u7531\u6210\u5343\u4e0a\u4e07\u751a\u81f3\u6570\u767e\u4e07\u4e2a\u5355\u4f53\u901a\u8fc7\u5171\u4ef7\u952e\u8fde\u63a5\u5f62\u6210\u94fe\u72b6\u7ed3\u6784\u7684\u9ad8\u5206\u5b50\u3002\u5c06\u8fd9\u4e9b\u5355\u4f53\u7ed3\u5408\u5f62\u6210\u805a\u5408\u7269\u7684\u8fc7\u7a0b\u88ab\u79f0\u4e3a\u805a\u5408\u53cd\u5e94\u3002\u805a\u5408\u7269\u5206\u4e3a\u4e24\u79cd\u7c7b\u578b\uff1a\u4e00\u79cd\u662f\u5408\u6210\u805a\u5408\u7269\uff0c\u5373\u901a\u8fc7\u5316\u5b66\u53cd\u5e94\u4eba\u5de5\u5236\u9020\u7684\u805a\u5408\u7269\uff1b\u53e6\u4e00\u79cd\u662f\u5929\u7136\u805a\u5408\u7269\uff0c\u7531\u751f\u7269\u4f53\u901a\u8fc7\u751f\u7269\u8fc7\u7a0b\u4ea7\u751f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u73b0\u4ee3\u805a\u5408\u7269\u5316\u5408\u7269\u7684\u914d\u65b9\u53ef\u80fd\u975e\u5e38\u590d\u6742\uff0c\u5305\u542b\u8bb8\u591a\u6210\u5206\u3002\u80fd\u591f\u7b80\u5316\u805a\u5408\u7269\u5f00\u53d1\u6d41\u7a0b\u7684\u8bbe\u5907\uff0c\u4f7f\u7814\u7a76\u4eba\u5458\u80fd\u591f\u5c1d\u8bd5\u4e0d\u540c\u6750\u6599\uff0c\u540c\u65f6\u786e\u4fdd\u4ea7\u54c1\u8d28\u91cf\u7684\u4e00\u81f4\u6027\u3002\u5408\u9002\u7684\u4eea\u5668\u8fd8\u80fd\u5e2e\u52a9\u79d1\u5b66\u5bb6\u5b9e\u73b0\u4ece\u5b9e\u9a8c\u5ba4\u89c4\u6a21\u6df7\u70bc\u5230\u5927\u89c4\u6a21\u751f\u4ea7\u7684\u8f6c\u53d8\uff0c\u5e76\u786e\u4fdd\u805a\u5408\u7269\u6750\u6599\u7b26\u5408\u76f8\u5173\u6807\u51c6\u548c\u6cd5\u89c4\u3002\u5148\u8fdb<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/applications.html?icid=CAD_blog_materials_2024Sept#polymer-compounds\">\u6324\u51fa\u8bbe\u5907<\/a>\u53ef\u4ee5\u4f18\u5316\u6df7\u70bc\u8fc7\u7a0b\uff0c\u4fc3\u8fdb\u8fd9\u4e9b\u590d\u6742\u805a\u5408\u7269\u6750\u6599\u7684\u751f\u4ea7\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e0\u8bba\u76ee\u6807\u662f\u4f18\u5316\u6750\u6599\u4f7f\u7528\u3001\u5f00\u53d1\u73af\u4fdd\u65b0\u578b\u805a\u5408\u7269\uff0c\u8fd8\u662f\u4fdd\u8bc1\u8d28\u91cf\u4e00\u81f4\u6027\uff0c\u6750\u6599\u79d1\u5b66\u5bb6\u90fd\u5e0c\u671b\u901a\u8fc7\u9886\u5148\u6280\u672f\u514b\u670d\u8fd9\u4e9b\u6311\u6218\uff0c\u66f4\u9ad8\u6548\u5730\u8fdb\u884c\u7814\u53d1\u5de5\u4f5c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u805a\u5408\u7269\u7c7b\u578b\"><strong>\u805a\u5408\u7269\u7c7b\u578b<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u805a\u5408\u7269\u6839\u636e\u5176\u5316\u5b66\u7ed3\u6784\u548c\u5355\u4f53\u6392\u5217\u65b9\u5f0f\uff0c\u53ef\u4ee5\u5177\u6709\u591a\u79cd\u4e0d\u540c\u7279\u6027\u3002\u4e00\u4e9b\u5e38\u89c1\u7684\u805a\u5408\u7269\u7279\u6027\u5305\u62ec\u67d4\u97e7\u6027\u3001\u575a\u97e7\u6027\u3001\u5f39\u6027\u3001\u70ed\u7a33\u5b9a\u6027\u3001\u7535\u7edd\u7f18\u6027\u80fd\u3001\u8010\u5316\u5b66\u8150\u8680\u4ee5\u53ca\u751f\u7269\u76f8\u5bb9\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5408\u6210\u805a\u5408\u7269\u662f\u901a\u8fc7\u5bf9\u77f3\u6cb9\u53ca\u5176\u4ed6\u539f\u6599\u884d\u751f\u7684\u5355\u4f53\u8fdb\u884c\u805a\u5408\u53cd\u5e94\u800c\u5236\u5f97\u3002\u4f8b\u5982\uff0c\u5e38\u89c1\u7684\u5408\u6210\u805a\u5408\u7269\u6709\u805a\u4e59\u70ef\uff08PE\uff09\u3001\u805a\u4e19\u70ef\uff08PP\uff09\u3001\u805a\u6c2f\u4e59\u70ef\uff08PVC\uff09\u3001\u805a\u82ef\u4e59\u70ef\uff08PS\uff09\u4ee5\u53ca\u805a\u5bf9\u82ef\u4e8c\u7532\u9178\u4e59\u4e8c\u9187\u916f\uff08PET\uff09\u3002\u901a\u8fc7\u6539\u53d8\u5176\u5316\u5b66\u7ed3\u6784\uff0c\u5408\u6210\u805a\u5408\u7269\u53ef\u9488\u5bf9\u5177\u4f53\u5e94\u7528\u9700\u6c42\u8c03\u6574\u6027\u80fd\uff0c\u5177\u5907\u5e7f\u6cdb\u7528\u9014\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5929\u7136\u805a\u5408\u7269\u987e\u540d\u601d\u4e49\u5b58\u5728\u4e8e\u81ea\u7136\u754c\uff0c\u7531\u53ef\u518d\u751f\u8d44\u6e90\u83b7\u5f97\uff0c\u662f\u7531\u751f\u7269\u4f53\u901a\u8fc7\u751f\u7406\u8fc7\u7a0b\u4ea7\u751f\u3002\u4f8b\u5982\u5929\u7136\u805a\u5408\u7269\u5305\u62ec\u86cb\u767d\u8d28\uff08\u5982\u80f6\u539f\u86cb\u767d\u548c\u4e1d\u7ef8\uff09\u3001\u6838\u9178\uff08\u5982DNA\u548cRNA\uff09\u3001\u78b3\u6c34\u5316\u5408\u7269\uff08\u5982\u7ea4\u7ef4\u7d20\u548c\u6dc0\u7c89\uff09\u4ee5\u53ca\u5929\u7136\u6a61\u80f6\u3002\u5929\u7136\u805a\u5408\u7269\u901a\u5e38\u5177\u6709\u72ec\u7279\u6027\u80fd\u548c\u826f\u597d\u7684\u751f\u7269\u76f8\u5bb9\u6027\uff0c\u4f7f\u5176\u9002\u7528\u4e8e\u98df\u54c1\u3001\u533b\u836f\u3001\u7eba\u7ec7\u54c1\u53ca\u5316\u5986\u54c1\u7b49\u591a\u4e2a\u9886\u57df\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5de5\u827a\u6d41\u7a0b\"><strong>\u5de5\u827a\u6d41\u7a0b<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u539f\u59cb\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\u6d89\u53ca\u591a\u4e2a\u5173\u952e\u6b65\u9aa4\uff0c\u8fd9\u4e9b\u6b65\u9aa4\u5bf9\u4e8e\u521b\u9020\u65b0\u7684\u805a\u5408\u7269\u6750\u6599\u81f3\u5173\u91cd\u8981\u3002\u4ee5\u4e0b\u662f\u4e00\u822c\u6d89\u53ca\u7684\u6b65\u9aa4\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u5355\u4f53\u9009\u62e9\uff1a<\/strong>\u5355\u4f53\u662f\u80fd\u591f\u76f8\u4e92\u53cd\u5e94\u5f62\u6210\u957f\u94fe\u7684\u5c0f\u5206\u5b50\uff0c\u662f\u805a\u5408\u7269\u7684\u57fa\u672c\u6784\u5efa\u5757\u3002\u9009\u62e9\u54ea\u4e9b\u5355\u4f53\u4f5c\u4e3a\u8d77\u59cb\u6750\u6599\u53d6\u51b3\u4e8e\u6700\u7ec8\u805a\u5408\u7269\u6240\u9700\u7684\u6027\u80fd\u548c\u7279\u6027\u3002<\/li>\n\n\n\n<li><strong>\u805a\u5408\u53cd\u5e94\uff1a<\/strong>\u805a\u5408\u53cd\u5e94\u662f\u5c06\u5355\u4f53\u901a\u8fc7\u5316\u5b66\u952e\u8fde\u63a5\u8d77\u6765\u5f62\u6210\u805a\u5408\u7269\u94fe\u7684\u8fc7\u7a0b\u3002\u805a\u5408\u65b9\u6cd5\u6709\u591a\u79cd\uff0c\u5305\u62ec\u52a0\u6210\u805a\u5408\u3001\u7f29\u805a\u548c\u5f00\u73af\u805a\u5408\u3002\u9009\u62e9\u54ea\u79cd\u805a\u5408\u65b9\u6cd5\u53d6\u51b3\u4e8e\u6240\u7528\u5355\u4f53\u4ee5\u53ca\u671f\u671b\u83b7\u5f97\u7684\u805a\u5408\u7269\u6027\u80fd\u3002<\/li>\n\n\n\n<li><strong>\u50ac\u5316\u5242\u4e0e\u5f15\u53d1\u5242\uff1a<\/strong>\u5728\u805a\u5408\u53cd\u5e94\u4e2d\u53ef\u80fd\u4f1a\u4f7f\u7528\u50ac\u5316\u5242\u6216\u5f15\u53d1\u5242\u6765\u4fc3\u8fdb\u53cd\u5e94\u3002\u50ac\u5316\u5242\u53ef\u4ee5\u63d0\u9ad8\u53cd\u5e94\u901f\u7387\uff0c\u800c\u5f15\u53d1\u5242\u5219\u901a\u8fc7\u751f\u6210\u81ea\u7531\u57fa\u6216\u5176\u4ed6\u6d3b\u6027\u7269\u79cd\u6765\u542f\u52a8\u805a\u5408\u53cd\u5e94\u3002<\/li>\n\n\n\n<li><strong>\u53cd\u5e94\u6761\u4ef6\uff1a<\/strong>\u6e29\u5ea6\u3001\u538b\u529b\u548c\u6eb6\u5242\u7b49\u53cd\u5e94\u6761\u4ef6\u5728\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\u4e2d\u8d77\u7740\u81f3\u5173\u91cd\u8981\u7684\u4f5c\u7528\u3002\u8fd9\u4e9b\u6761\u4ef6\u4f1a\u5f71\u54cd\u53cd\u5e94\u901f\u7387\u3001\u5206\u5b50\u91cf\u3001\u805a\u5408\u7269\u7ed3\u6784\u4ee5\u53ca\u6700\u7ec8\u4ea7\u54c1\u7684\u6574\u4f53\u6027\u80fd\u3002<\/li>\n\n\n\n<li><strong>\u7eaf\u5316\uff1a<\/strong>\u5728\u5b8c\u6210\u805a\u5408\u53cd\u5e94\u540e\uff0c\u901a\u5e38\u9700\u8981\u5bf9\u6240\u5f97\u7684\u805a\u5408\u7269\u8fdb\u884c\u7eaf\u5316\uff0c\u4ee5\u53bb\u9664\u6742\u8d28\u6216\u672a\u53cd\u5e94\u7684\u5355\u4f53\u3002\u7eaf\u5316\u8fc7\u7a0b\u53ef\u4ee5\u91c7\u7528\u8fc7\u6ee4\u3001\u6c89\u6dc0\u6216\u8403\u53d6\u7b49\u6280\u672f\u3002<\/li>\n\n\n\n<li><strong>\u8868\u5f81\uff1a<\/strong>\u4e0b\u4e00\u6b65\u662f<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/applications.html?icid=CAD_blog_materials_2024Sept#polymer-characterization\">\u5bf9\u805a\u5408\u7269\u7684\u6027\u8d28\u8fdb\u884c\u8868\u5f81<\/a>\u3002\u8fd9\u5305\u62ec\u5206\u6790\u5176\u5206\u5b50\u91cf\u3001\u70ed\u7a33\u5b9a\u6027\u3001\u673a\u68b0\u6027\u80fd\u3001\u5316\u5b66\u8010\u53d7\u6027\u4ee5\u53ca\u5176\u4ed6\u76f8\u5173\u7279\u6027\u3002\u91c7\u7528\u5149\u8c31\u6cd5\u3001\u8272\u8c31\u6cd5\u548c\u663e\u5fae\u955c\u7b49\u591a\u79cd\u6280\u672f\u6765\u8bc4\u4f30\u805a\u5408\u7269\u7684\u6027\u80fd\u3002<\/li>\n\n\n\n<li><strong>\u6d4b\u8bd5\u4e0e\u4f18\u5316\uff1a<\/strong>\u5728\u805a\u5408\u7269\u5b8c\u6210\u8868\u5f81\u540e\uff0c\u9700\u8981\u901a\u8fc7\u6d4b\u8bd5\u6765\u8bc4\u4f30\u5176\u5728\u7279\u5b9a\u5e94\u7528\u4e2d\u7684\u8868\u73b0\u3002\u8fd9\u53ef\u80fd\u6d89\u53ca\u5f3a\u5ea6\u3001\u67d4\u97e7\u6027\u3001\u8010\u4e45\u6027\u6216\u5316\u5b66\u8010\u53d7\u6027\u7684\u6d4b\u8bd5\u3002\u6839\u636e\u6d4b\u8bd5\u7ed3\u679c\uff0c\u53ef\u4ee5\u5bf9\u805a\u5408\u7269\u914d\u65b9\u8fdb\u884c\u8c03\u6574\u6216\u4fee\u6539\uff0c\u4ee5\u4f18\u5316\u5176\u6027\u80fd\u3002<\/li>\n\n\n\n<li><strong>\u653e\u5927\u751f\u4ea7\u4e0e\u5236\u9020\uff1a<\/strong>\u7ecf\u8fc7\u6210\u529f\u7684\u6d4b\u8bd5\u548c\u4f18\u5316\u540e\uff0c\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\u5c06\u8fdb\u5165\u653e\u5927\u751f\u4ea7\u9636\u6bb5\u3002\u8fd9\u5305\u62ec\u5927\u89c4\u6a21\u751f\u4ea7\u805a\u5408\u7269\uff0c\u4f18\u5316\u5236\u9020\u6d41\u7a0b\uff0c\u5e76\u786e\u4fdd\u8d28\u91cf\u63a7\u5236\u7684\u4e00\u81f4\u6027\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u9700\u8981\u6ce8\u610f\u7684\u662f\uff0c\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\u4e2d\u6d89\u53ca\u7684\u5177\u4f53\u6b65\u9aa4\u548c\u6d41\u7a0b\u4f1a\u6839\u636e\u6240\u9700\u6027\u80fd\u3001\u5e94\u7528\u9886\u57df\u53ca\u5f00\u53d1\u7684\u805a\u5408\u7269\u7c7b\u578b\u800c\u6709\u6240\u4e0d\u540c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u805a\u5408\u7269\u6df7\u914d\"><strong>\u805a\u5408\u7269\u6df7\u914d<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5851\u6599\u7684\u591a\u6837\u6027\u662f\u901a\u8fc7\u805a\u5408\u7269\u6df7\u914d\u6765\u6ee1\u8db3\u5e7f\u6cdb\u6f5c\u5728\u5e94\u7528\u9700\u6c42\u7684\u3002\u6df7\u914d\u662f\u5c06\u6811\u8102\u901a\u8fc7\u4f7f\u7528\u4e00\u79cd\u6216\u591a\u79cd\u805a\u5408\u7269\u6811\u8102\u53ca\u76f8\u5e94\u6dfb\u52a0\u5242\uff0c\u914d\u5236\u6210\u5b9a\u5236\u6750\u6599\uff0c\u4ee5\u6ee1\u8db3\u67d0\u4e00\u5e94\u7528\u7684\u5177\u4f53\u8981\u6c42\u3002\u4f8b\u5982\uff0c\u5728\u7269\u7406\u6027\u80fd\u65b9\u9762\uff0c\u8fd9\u53ef\u80fd\u610f\u5473\u7740\u5f00\u53d1\u5177\u6709\u66f4\u597d\u8010\u70ed\u6027\u3001\u66f4\u9ad8\u5f3a\u5ea6\u6216\u66f4\u5927\u67d4\u97e7\u6027\u7684\u6750\u6599\uff0c\u6216\u8005\u4ec5\u4ec5\u662f\u786e\u4fdd\u6b63\u786e\u7684\u7740\u8272\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcd\u7c92\u4e5f\u662f\u4e00\u79cd\u5316\u5408\u7269\uff0c\u7531\u81f3\u5c11\u4e24\u79cd\u7ec4\u5206\u901a\u8fc7\u6324\u51fa\u5de5\u827a\u6df7\u5408\u800c\u6210\u3002\u201c\u6bcd\u7c92\u201d\u6307\u7684\u662f\u4ee5\u9897\u7c92\u5f62\u5f0f\u5b58\u5728\u3001\u542b\u6709\u6bd4\u6700\u7ec8\u5e94\u7528\u4e2d\u66f4\u9ad8\u6d53\u5ea6\u7740\u8272\u5242\u6216\u6dfb\u52a0\u5242\u7684\u5851\u6599\u6dfb\u52a0\u5242\u3002\u5b83\u4eec\u88ab\u52a0\u5165\u5230\u805a\u5408\u7269\u4e2d\uff0c\u7528\u4e8e\u7740\u8272\u6216\u6539\u53d8\u5176\u6027\u80fd\u3002\u4e0e\u7c89\u672b\u6dfb\u52a0\u5242\u76f8\u6bd4\uff0c\u6bcd\u7c92\u63d0\u9ad8\u4e86\u6280\u672f\u5de5\u827a\u7684\u53ef\u9760\u6027\uff0c\u5e76\u4e14\u6613\u4e8e\u52a0\u5de5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3b\u8981\u7684\u6df7\u914d\u6b65\u9aa4\u5305\u62ec\u6295\u6599\u3001\u7194\u878d\u3001\u8f93\u9001\u3001\u6df7\u5408\u3001\u6392\u6c14\uff0c\u4ee5\u53ca<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/o\/a\/extrusion-possibilities-new-polymer-development.html?icid=CAD_blog_materials_2024Sept\">\u6324\u51fa<\/a>\u5747\u8d28\u4ea7\u54c1\u7684\u6210\u578b\u3002\u5728\u6295\u6599\u533a\uff0c\u901a\u8fc7\u4f53\u79ef\u5f0f\u6216\u91cd\u529b\u5f0f\u5582\u6599\u5668\u5c06\u56fa\u4f53\u6750\u6599\u6295\u5165\u7cfb\u7edf\u3002\u7a7a\u6c14\u88ab\u79fb\u9664\uff0c\u4f4e\u5bc6\u5ea6\u6750\u6599\u88ab\u538b\u5b9e\u3002\u5728\u4e0b\u4e00\u6b65\uff0c\u6750\u6599\u5728\u90e8\u5206\u586b\u5145\u4e14\u65e0\u538b\u529b\u7684\u8f93\u9001\u6bb5\u5411\u524d\u79fb\u52a8\u5e76\u52a0\u70ed\u3002\u5728\u7b2c\u4e00\u4e2a\u6df7\u5408\u533a\uff0c\u6750\u6599\u88ab\u7194\u5316\u548c\u5851\u5316\u3002\u6df7\u5408\u533a\u5b8c\u5168\u5145\u6ee1\u6750\u6599\u3002\u968f\u540e\u8fdb\u5165\u53e6\u4e00\u4e2a\u8f93\u9001\u533a\uff0c\u53ef\u7528\u4e8e\u6392\u6c14\u3001\u5206\u6279\u6295\u653e\u586b\u6599\u6216\u6db2\u4f53\u6295\u653e\u3002\u4e4b\u540e\u4ea4\u66ff\u8fdb\u884c\u6df7\u5408\u548c\u8f93\u9001\u6bb5\uff0c\u4ee5\u5b9e\u73b0\u4ea7\u54c1\u5747\u5300\u5316\u3002\u5728\u6392\u6c14\u533a\u57df\u5185\u7684\u8f93\u9001\u87ba\u6746\u5143\u4ef6\u7528\u4e8e\u5728\u5e38\u538b\u6216\u771f\u7a7a\u4e0b\u6392\u9664\u6325\u53d1\u7269\u548c\u7a7a\u6c14\u3002\u6700\u540e\uff0c\u901a\u8fc7\u6324\u51fa\u6bb5\u5efa\u7acb\u538b\u529b\u5e76\u5bf9\u6750\u6599\u8fdb\u884c\u6210\u578b\u3002\u5728\u5927\u591a\u6570\u5e94\u7528\u4e2d\uff0c\u4f1a\u6324\u51fa\u6761\u72b6\u7269\uff0c\u7136\u540e\u5728\u6c34\u6d74\u4e2d\u51b7\u5374\u5e76\u5207\u5272\u6210\u9897\u7c92\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u79d1\u7814\u4eba\u5458\u548c\u5de5\u4e1a\u754c\u4e00\u76f4\u81f4\u529b\u4e8e\u6750\u6599\u5f00\u53d1\uff0c\u4ee5\u4fbf\u6539\u826f\u5316\u5408\u7269\uff0c\u4f7f\u5176\u5177\u6709\u66f4\u4f18\u5f02\u6027\u80fd\u3001\u66f4\u597d\u7684\u53ef\u91cd\u590d\u5229\u7528\u6027\u6216\u589e\u5f3a\u53ef\u6301\u7eed\u6027\u3002\u9700\u8981\u7cfb\u7edf\u6027\u7684\u5f00\u53d1\u65b9\u6cd5\u6765\u786e\u5b9a\u6700\u9002\u7528\u4e8e\u7279\u5b9a\u5e94\u7528\u7684\u5316\u5408\u7269\u7ec4\u6210\uff0c\u5e76\u7814\u7a76\u65b0\u578b\u6750\u6599\u751f\u4ea7\u8fc7\u7a0b\u4e2d\u7684\u53ef\u52a0\u5de5\u6027\u3002\u5728\u5f00\u53d1\u65e9\u671f\u9636\u6bb5\uff0c\u7528\u4e8e\u8fd9\u4e9b\u65b0\u5316\u5408\u7269\u7684\u65b0\u578b\u6750\u6599\u53ef\u80fd\u53ea\u83b7\u5f97\u5c11\u91cf\u6837\u54c1\u3002\u4e3a\u89e3\u51b3\u8fd9\u4e00\u95ee\u9898\uff0c\u7814\u7a76\u4eba\u5458\u53ef\u4ee5\u91c7\u7528\u5c0f\u89c4\u6a21\u6324\u51fa\u673a\u6216\u5fae\u578b\u6df7\u914d\u5668\u6765\u8bc4\u4f30\u6df7\u914d\u884c\u4e3a\uff0c\u5e76\u8fdb\u4e00\u6b65\u8868\u5f81\u805a\u5408\u7269\u6027\u80fd\u3002\u4e00\u53f0\u80fd\u591f\u5728\u6df7\u914d\u8fc7\u7a0b\u4e2d\u68c0\u6d4b\u76f8\u5bf9\u7c98\u5ea6\u7684\u5fae\u578b\u6df7\u914d\u5668\uff0c\u53ef\u4ee5\u63d0\u4f9b\u5173\u4e8e\u56e0\u6df7\u914d\u8fc7\u7a0b\u5f15\u8d77\u7ed3\u6784\u53d8\u5316\u7684\u989d\u5916\u4fe1\u606f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u603b\u7ed3\"><strong>\u603b\u7ed3<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u603b\u4f53\u800c\u8a00\uff0c\u805a\u5408\u7269\u4f5c\u4e3a\u5173\u952e\u6750\u6599\uff0c\u7531\u4e8e\u5176\u72ec\u7279\u6027\u80fd\u548c\u6ee1\u8db3\u5404\u884c\u4e1a\u53ca\u4e0d\u540c\u5e94\u7528\u9700\u6c42\u7684\u591a\u529f\u80fd\u6027\uff0c\u5df2\u7ecf\u5f7b\u5e95\u6539\u53d8\u4e86\u73b0\u4ee3\u751f\u6d3b\u8bf8\u591a\u65b9\u9762\u3002\u805a\u5408\u7269\u79d1\u5b66\u9886\u57df\u7684\u7814\u53d1\u4e0d\u65ad\u8fdb\u6b65\uff0c\u4e0d\u65ad\u53d1\u73b0\u65b0\u7684\u65b9\u6cd5\u548c\u6280\u672f\u7528\u4e8e\u805a\u5408\u7269\u5f00\u53d1\u3002\u6324\u51fa\u6280\u672f\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u7ecf\u6d4e\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u6709\u52a9\u4e8e\u66f4\u5feb\u5730\u5f00\u53d1\u65b0\u578b\u6750\u6599\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u66f4\u591a\u8d44\u6e90\"><strong>\u66f4\u591a\u8d44\u6e90<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/o\/a\/extrusion-possibilities-new-polymer-development.html?icid=CAD_blog_materials_2024Sept\">\u6324\u51fa\u6280\u672f<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html?icid=CAD_blog_materials_2024Sept\">\u590d\u5408\u4e0e\u6324\u51fa\u5728\u7ebf\u8d44\u6e90<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/SN53421-low-bulk-density-fillers-polymers-extrusion.pdf?icid=CAD_blog_materials_2024Sept\">\u5e94\u7528\u8bf4\u660e\uff1a\u5728\u805a\u5408\u7269\u590d\u5408\u6750\u6599\u4e2d\u52a0\u5165\u654f\u611f\u6216\u4f4e\u5806\u79ef\u5bc6\u5ea6\u586b\u6599<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/brochures\/CO64729-Recycling-EN.pdf?icid=CAD_blog_materials_2024Sept\">\u805a\u5408\u7269\u53ef\u6301\u7eed\u6027\u5e94\u7528\u6c47\u7f16<\/a><\/li>\n\n\n\n<li><a href=\"http:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/reactive-extrusion-en-sn64714.pdf?icid=CAD_blog_materials_2024Sept\">\u5e94\u7528\u8bf4\u660e\uff1a\u4e3a\u4ec0\u4e48\u8981\u4f7f\u7528\u53cc\u87ba\u6746\u6324\u51fa\u673a\u8fdb\u884c\u6709\u673a\u53cd\u5e94\uff1f<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/LR96-benefits-of-solvent-reduced-twin-screw-compounding.pdf?icid=CAD_blog_materials_2024Sept\">\u5e94\u7528\u8bf4\u660e\uff1a\u6eb6\u5242\u51cf\u5c11\u578b\u53cc\u87ba\u6746\u590d\u5408\u5bf9\u9ad8\u6548\u3001\u73af\u4fdd\u53ca\u9ad8\u6027\u80fd\u9502\u79bb\u5b50\u7535\u6c60\u7684\u6210\u672c\u6548\u76ca\u4f18\u52bf<\/a><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u5f53\u6750\u6599\u79d1\u5b66\u5bb6\u5bfb\u6c42\u5f00\u53d1\u65b0\u7684\u8f7b\u8d28\u3001\u67d4\u6027\u3001\u7ecf\u6d4e\u9ad8\u6548\u6216\u5176\u4ed6\u66f4\u4f18\u89e3\u51b3\u65b9\u6848\u65f6\uff0c\u4ed6\u4eec\u7ecf\u5e38\u4f1a\u5173\u6ce8\u805a\u5408\u7269\u3002\u5bf9\u4e8e\u98df\u54c1\u5305\u88c5\u3001\u6c7d\u8f66\u96f6\u90e8<\/p>\n","protected":false},"author":1852,"featured_media":667,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[51,53],"tags":[82],"division":[52],"class_list":["post-666","post","type-post","status-publish","format-standard","has-post-thumbnail","category-51","category-53","tag-82","division-cad","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\" \/>\n<meta property=\"og:description\" content=\"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-10T02:34:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-10T02:34:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2301\" \/>\n\t<meta property=\"og:image:height\" content=\"1303\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\",\"datePublished\":\"2026-03-10T02:34:48+00:00\",\"dateModified\":\"2026-03-10T02:34:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/\"},\"wordCount\":7,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1090036338_polymerlab.jpg\",\"keywords\":[\"\u805a\u5408\u7269\u5f00\u53d1\"],\"articleSection\":[\"\u6750\u6599\u79d1\u5b66\",\"\u91c7\u77ff\u4e0e\u52a0\u5de5\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/\",\"name\":\"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1090036338_polymerlab.jpg\",\"datePublished\":\"2026-03-10T02:34:48+00:00\",\"dateModified\":\"2026-03-10T02:34:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1090036338_polymerlab.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/iStock-1090036338_polymerlab.jpg\",\"width\":2301,\"height\":1303},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/the-polymer-development-process\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/","og_locale":"zh_CN","og_type":"article","og_title":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b","og_description":"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-10T02:34:48+00:00","article_modified_time":"2026-03-10T02:34:50+00:00","og_image":[{"width":2301,"height":1303,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/the-polymer-development-process\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b","datePublished":"2026-03-10T02:34:48+00:00","dateModified":"2026-03-10T02:34:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/the-polymer-development-process\/"},"wordCount":7,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg","keywords":["\u805a\u5408\u7269\u5f00\u53d1"],"articleSection":["\u6750\u6599\u79d1\u5b66","\u91c7\u77ff\u4e0e\u52a0\u5de5"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/the-polymer-development-process\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/","name":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg","datePublished":"2026-03-10T02:34:48+00:00","dateModified":"2026-03-10T02:34:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u4e86\u89e3\u6324\u51fa\u5de5\u827a\u5982\u4f55\u5e2e\u52a9\u6750\u6599\u79d1\u5b66\u5bb6\u9ad8\u6548\u4e14\u5177\u6709\u6210\u672c\u6548\u76ca\u5730\u8fdb\u884c\u5927\u91cf\u8bd5\u9a8c\uff0c\u4ece\u800c\u66f4\u5feb\u5730\u5f00\u53d1\u51fa\u65b0\u6750\u6599\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab.jpg","width":2301,"height":1303},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/the-polymer-development-process\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u805a\u5408\u7269\u5f00\u53d1\u8fc7\u7a0b"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":51,"label":"\u6750\u6599\u79d1\u5b66"},{"value":53,"label":"\u91c7\u77ff\u4e0e\u52a0\u5de5"}],"post_tag":[{"value":82,"label":"\u805a\u5408\u7269\u5f00\u53d1"}],"division":[{"value":52,"label":"CAD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/iStock-1090036338_polymerlab-1024x580.jpg",760,430,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":51,"name":"\u6750\u6599\u79d1\u5b66","slug":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":51,"taxonomy":"category","description":"","parent":0,"count":30,"filter":"raw","meta":[],"cat_ID":51,"category_count":30,"category_description":"","cat_name":"\u6750\u6599\u79d1\u5b66","category_nicename":"%e6%9d%90%e6%96%99%e7%a7%91%e5%ad%a6","category_parent":0},{"term_id":53,"name":"\u91c7\u77ff\u4e0e\u52a0\u5de5","slug":"%e9%87%87%e7%9f%bf%e4%b8%8e%e5%8a%a0%e5%b7%a5","term_group":0,"term_taxonomy_id":53,"taxonomy":"category","description":"","parent":0,"count":7,"filter":"raw","meta":[],"cat_ID":53,"category_count":7,"category_description":"","cat_name":"\u91c7\u77ff\u4e0e\u52a0\u5de5","category_nicename":"%e9%87%87%e7%9f%bf%e4%b8%8e%e5%8a%a0%e5%b7%a5","category_parent":0}],"tag_info":[{"term_id":82,"name":"\u805a\u5408\u7269\u5f00\u53d1","slug":"%e8%81%9a%e5%90%88%e7%89%a9%e5%bc%80%e5%8f%91","term_group":0,"term_taxonomy_id":82,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/666","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=666"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/666\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/667"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=666"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=666"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=666"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=666"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}