{"id":713,"date":"2026-03-09T05:32:04","date_gmt":"2026-03-09T05:32:04","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=713"},"modified":"2026-03-09T05:32:06","modified_gmt":"2026-03-09T05:32:06","slug":"hmw-dna-extraction-101","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/","title":{"rendered":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/HMW-Blog-Image-1024x668.jpg\" alt=\"HMW DNA Extraction\" class=\"wp-image-4964\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u63d0\u53d6\u9ad8\u8d28\u91cf\u3001\u5b8c\u6574\u7684\u57fa\u56e0\u7ec4DNA\u662f\u8bb8\u591a\u540e\u7eed\u5206\u5b50\u5e94\u7528\u7684\u57fa\u7840\u6b65\u9aa4\u2014\u2014\u4f46\u5e76\u975e\u6240\u6709DNA\u90fd\u662f\u4e00\u6837\u7684\u3002\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u7684\u63d0\u53d6\u5bf9\u4e8e\u5b9e\u73b0\u4f9d\u8d56\u4e8e\u957f\u4e14\u672a\u788e\u7247\u5316DNA\u94fe\u7684\u9ad8\u7ea7\u57fa\u56e0\u7ec4\u5206\u6790\u81f3\u5173\u91cd\u8981\uff0c\u5c24\u5176\u662f\u5728\u7ed3\u6784\u53d8\u5f02\u68c0\u6d4b\u3001\u57fa\u56e0\u7ec4\u7ec4\u88c5\u548c\u8868\u89c2\u9057\u4f20\u5206\u6790\u4e2d\u3002<\/p>\n\n\n\n<p>\u968f\u7740\u957f\u8bfb\u957f\u6d4b\u5e8f\u6280\u672f\u7684\u5174\u8d77\uff0c\u80fd\u591f\u7a33\u5b9a\u5730\u5206\u79bb\u51fa\u5927\u4e8e40 kb\u3001\u751a\u81f3\u8d85\u8fc7100 kb\u7684DNA\u7247\u6bb5\u5df2\u4e0d\u518d\u662f\u5962\u4f88\uff0c\u800c\u6210\u4e3a\u5c16\u7aef\u57fa\u56e0\u7ec4\u79d1\u5b66\u7684\u5fc5\u9700\u6761\u4ef6\u3002<\/p>\n\n\n\n<p>\u7406\u89e3DNA\u7684\u590d\u6742\u6027\u5bf9\u4e8e\u57fa\u56e0\u7ec4\u5b66\u548c\u751f\u7269\u6280\u672f\u7684\u53d1\u5c55\u81f3\u5173\u91cd\u8981\u3002\u8bf8\u5982\u57fa\u56e0\u7ec4DNA\u3001\u9ad8\u5206\u5b50\u91cfDNA\u4ee5\u53ca\u521b\u65b0\u6027\u7684\u957f\u8bfb\u957f\u6d4b\u5e8f\u6280\u672f\u7b49\u57fa\u672c\u6982\u5ff5\uff0c\u901a\u8fc7\u4f7f\u65e0\u53c2\u8003\u7ec4\u88c5\u6210\u4e3a\u53ef\u80fd\uff0c\u5f7b\u5e95\u6539\u53d8\u4e86de-novo\u6d4b\u5e8f\u7684\u6548\u679c\u3002\u5728\u672c\u6587\u4e2d\uff0c\u6211\u4eec\u5c06\u6df1\u5165\u63a2\u8ba8\u4e0d\u540c\u7c7b\u578b\u57fa\u56e0\u7ec4DNA\u7ed3\u6784\uff0c\u5305\u62ec\u9ad8\u5206\u5b50\u91cfDNA\uff0c\u5e76\u5206\u6790\u5b83\u4eec\u5982\u4f55\u5f71\u54cd\u957f\u8bfb\u957f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f\uff0c\u63ed\u793a\u5176\u72ec\u7279\u5e94\u7528\u548c\u4f18\u52bf\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-yoast-seo-table-of-contents yoast-table-of-contents\"><h2>\u76ee\u5f55<\/h2><ul><li><a href=\"#h-\u4ec0\u4e48\u662f\u57fa\u56e0\u7ec4dna\" data-level=\"2\">\u4ec0\u4e48\u662f\u57fa\u56e0\u7ec4DNA\uff1f<\/a><\/li><li><a href=\"#h-\u4ec0\u4e48\u662f\u9ad8\u5206\u5b50\u91cfdna\" data-level=\"2\">\u4ec0\u4e48\u662f\u9ad8\u5206\u5b50\u91cfDNA\uff1f<\/a><\/li><li><a href=\"#h-\u957f\u8bfb\u957f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f-\u6709\u4ec0\u4e48\u533a\u522b\" data-level=\"2\">\u957f\u8bfb\u957f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f\uff1a\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/a><ul><li><a href=\"#h-\u77ed\u8bfb\u957f\u6d4b\u5e8f\" data-level=\"3\">\u77ed\u8bfb\u957f\u6d4b\u5e8f<\/a><\/li><li><a href=\"#h-\u957f\u8bfb\u957f\u6d4b\u5e8f\" data-level=\"3\">\u957f\u8bfb\u957f\u6d4b\u5e8f<\/a><\/li><li><a href=\"#h-\u6709\u4ec0\u4e48\u533a\u522b\" data-level=\"3\">\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/a><\/li><\/ul><\/li><li><a href=\"#h-\u6bd4\u8f83\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u4f18\u52bf\u4e0e\u5e94\u7528\" data-level=\"2\">\u6bd4\u8f83\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u4f18\u52bf\u4e0e\u5e94\u7528<\/a><\/li><li><a href=\"#h-\u9ad8\u5206\u5b50\u91cf-hmw-dna\u5bf9\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u91cd\u8981\u6027\u662f\u4ec0\u4e48\" data-level=\"2\">\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u5bf9\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u91cd\u8981\u6027\u662f\u4ec0\u4e48\uff1f<\/a><\/li><li><a href=\"#h-\u9ad8\u5206\u5b50\u91cfdna\u63d0\u53d6\" data-level=\"2\">\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6<\/a><\/li><li><a href=\"#h-\u4e86\u89e3\u5e38\u89c1\u7684\u9ad8\u5206\u5b50\u91cfdna\u63d0\u53d6\u6311\u6218\" data-level=\"2\">\u4e86\u89e3\u5e38\u89c1\u7684\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u6311\u6218<\/a><ul><li><a href=\"#h-1-\u4ea7\u91cf\u4f4e\u7684\u6837\u54c1\" data-level=\"3\">1. \u4ea7\u91cf\u4f4e\u7684\u6837\u54c1<\/a><\/li><li><a href=\"#h-2-\u6d17\u8131\u6db2\u7c98\u7a20\u6216\u5448\u68d5\u8272\" data-level=\"3\">2. \u6d17\u8131\u6db2\u7c98\u7a20\u6216\u5448\u68d5\u8272<\/a><\/li><li><a href=\"#h-3-\u9ad8\u5206\u5b50\u91cfdna\u964d\u89e3\" data-level=\"3\">3. \u9ad8\u5206\u5b50\u91cfDNA\u964d\u89e3<\/a><\/li><\/ul><\/li><li><a href=\"#h-hmw-dna\u63d0\u53d6\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\" data-level=\"2\">HMW DNA\u63d0\u53d6\u5e38\u89c1\u95ee\u9898\u89e3\u7b54<\/a><\/li><li><a href=\"#h-\u5173\u4e8ehmw\u63d0\u53d6\u4ee5\u53ca\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u66f4\u591a\u8d44\u6e90\" data-level=\"2\">\u5173\u4e8eHMW\u63d0\u53d6\u4ee5\u53ca\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u66f4\u591a\u8d44\u6e90<\/a><\/li><\/ul><\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662f\u57fa\u56e0\u7ec4dna\">\u4ec0\u4e48\u662f\u57fa\u56e0\u7ec4DNA\uff1f<\/h2>\n\n\n\n<p>\u57fa\u56e0\u7ec4DNA\uff08gDNA\uff09\u6307\u7684\u662f\u4e00\u4e2a\u751f\u7269\u4f53\u5185\u7684\u5168\u90e8DNA\uff0c\u5305\u62ec\u6240\u6709\u57fa\u56e0\u548c\u975e\u7f16\u7801\u533a\u57df\u3002\u57fa\u56e0\u7ec4DNA\u901a\u5e38\u53ef\u7528\u4e8e\u5206\u5b50\u5e94\u7528\uff0c\u5982PCR\u3001\u6d4b\u5e8f\u548c\u4e0b\u4e00\u4ee3\u6d4b\u5e8f\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4ec0\u4e48\u662f\u9ad8\u5206\u5b50\u91cfdna\">\u4ec0\u4e48\u662f\u9ad8\u5206\u5b50\u91cfDNA\uff1f<\/h2>\n\n\n\n<p>\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u7279\u6307\u90a3\u4e9b\u6781\u5176\u957f\u4e14\u5b8c\u6574\u7684DNA\u5206\u5b50\uff0c\u901a\u5e38\u957f\u5ea6\u4ece\u6570\u767e\u5343\u78b1\u57fa\u5230\u767e\u4e07\u78b1\u57fa\u4e0d\u7b49\u3002\u867d\u7136gDNA\u5305\u542b\u6240\u6709\u9057\u4f20\u7269\u8d28\uff0c\u4f46HMW DNA\u4ee5\u5176\u8f83\u5927\u7684\u5c3a\u5bf8\u548c\u9ad8\u5ea6\u5b8c\u6574\u6027\u4e3a\u7279\u70b9\uff0c\u4f7f\u5176\u5728\u9700\u8981\u957f\u3001\u8fde\u7eedDNA\u94fe\u8fdb\u884c\u51c6\u786e\u5206\u6790\u548c\u7ec4\u88c5\u7684\u5e94\u7528\u4e2d\uff08\u5982\u957f\u8bfb\u957f\u6d4b\u5e8f\u548c\u5168\u65b0\u57fa\u56e0\u7ec4\u7ec4\u88c5\uff09\u5c24\u4e3a\u91cd\u8981\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u957f\u8bfb\u957f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f-\u6709\u4ec0\u4e48\u533a\u522b\">\u957f\u8bfb\u957f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f\uff1a\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/h2>\n\n\n\n<p>\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u65b9\u6cd5\u4e3b\u8981\u533a\u522b\u5728\u4e8e\u5b83\u4eec\u80fd\u591f\u5206\u6790\u7684DNA\u7247\u6bb5\u957f\u5ea6\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u77ed\u8bfb\u957f\u6d4b\u5e8f\">\u77ed\u8bfb\u957f\u6d4b\u5e8f<\/h3>\n\n\n\n<p>\u77ed\u8bfb\u957f\u6d4b\u5e8f<br>\u2014\u2014\u6700\u5e38\u7528\u7684\u5927\u89c4\u6a21\u5e76\u884c\u6d4b\u5e8f\u6216\u4e0b\u4e00\u4ee3\u6d4b\u5e8f\uff08NGS\uff09\u5f62\u5f0f\u2014\u2014\u662f\u4e00\u79cd\u5e7f\u6cdb\u91c7\u7528\u7684\u65b9\u6cd5\uff0c\u80fd\u591f\u751f\u6210\u6570\u767e\u4e07\u5230\u6570\u5341\u4ebf\u4e2a\u901a\u5e38\u957f\u5ea6\u4e3a50\u81f3300\u4e2a\u78b1\u57fa\u5bf9\u7684DNA\u7247\u6bb5\u3002\u7531\u4e8e\u5176\u9ad8\u901a\u91cf\u3001\u6bcf\u78b1\u57fa\u4f4e\u6210\u672c\u4ee5\u53ca\u6210\u719f\u7684\u4fe1\u606f\u5206\u6790\u6d41\u7a0b\uff0c\u8fc7\u53bb\u5341\u5e74\u91cc\u5b83\u6210\u4e3a\u7814\u7a76\u4e0e\u4e34\u5e8a\u5b9e\u9a8c\u5ba4\u4e3b\u6d41\u7684\u6d4b\u5e8f\u6280\u672f\u3002\u4eceRNA-seq\u5230\u9776\u5411\u91cd\u6d4b\u5e8f\u53ca\u5fae\u751f\u7269\u5206\u6790\uff0c\u77ed\u8bfb\u957f\u5e73\u53f0\u63a8\u52a8\u4e86\u65e0\u6570\u751f\u547d\u79d1\u5b66\u7a81\u7834\u3002\u7136\u800c\uff0c\u5c3d\u7ba1\u77ed\u8bfb\u957f\u6d4b\u5e8f\u5728\u53d8\u5f02\u68c0\u6d4b\u548c\u5b9a\u91cf\u65b9\u9762\u8868\u73b0\u51fa\u8272\uff0c\u4f46\u5728\u91cd\u590d\u533a\u57df\u3001\u7ed3\u6784\u53d8\u5f02\u53ca\u5355\u500d\u578b\u5206\u8fa8\u65b9\u9762\u5b58\u5728\u4e0d\u8db3\u2014\u2014\u8fd9\u4e9b\u9886\u57df\u6b63\u9010\u6e10\u88ab\u66f4\u9002\u5408\u7684\u957f\u8bfb\u957f\u6d4b\u5e8f\u6240\u9752\u7750\u3002\u77ed\u8bfb\u957f\u6d4b\u5e8f\u4ecd\u7136\u56e0\u5176\u53ef\u6269\u5c55\u6027\u3001\u53ef\u9760\u6027\u53ca\u5e7f\u6cdb\u5e94\u7528\u57fa\u7840\u800c\u5907\u53d7\u6b22\u8fce\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u957f\u8bfb\u957f\u6d4b\u5e8f\">\u957f\u8bfb\u957f\u6d4b\u5e8f<\/h3>\n\n\n\n<p>\u957f\u8bfb\u957f\u6d4b\u5e8f\u662f\u4e00\u79cdDNA\u6d4b\u5e8f\u6280\u672f\uff0c\u80fd\u591f\u4ea7\u751f\u76f8\u5bf9\u8f83\u957f\u7684\u5e73\u5747\u8bfb\u53d6\u957f\u5ea6\uff0c\u901a\u5e38\u4ece\u51e0\u5343\u5230\u5341\u51e0\u4e07\u751a\u81f3\u8d85\u8fc7\u5341\u4e07\u78b1\u57fa\u5bf9\u3002\u957f\u8bfb\u957f\u6d4b\u5e8f\u6280\u672f\u5728\u8bf8\u5982\u5168\u65b0\u57fa\u56e0\u7ec4\u7ec4\u88c5\u3001\u7ed3\u6784\u53d8\u5f02\u68c0\u6d4b\u4ee5\u53ca\u89e3\u51b3\u5355\u500d\u578b\u5206\u578b\u7b49\u5e94\u7528\u4e2d\u5c24\u4e3a\u91cd\u8981\uff0c\u4f7f\u5f97\u5bf9\u57fa\u56e0\u7ec4\u6709\u66f4\u5168\u9762\u7684\u4e86\u89e3\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6709\u4ec0\u4e48\u533a\u522b\">\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/h3>\n\n\n\n<p>\u957f\u8bfb\u957f\u6d4b\u5e8f\u4e0e\u77ed\u8bfb\u957f\u6d4b\u5e8f\u4e0d\u540c\u4e4b\u5904\u5728\u4e8e\u5b83\u80fd\u591f\u6d4b\u5e8f\u66f4\u957f\u7684DNA\u7247\u6bb5\uff08\u6570\u5343\u5230\u6570\u5341\u4e07\u78b1\u57fa\u5bf9\uff09\uff0c\u800c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u5219\u4f7f\u7528\u8f83\u77ed\u7684\u7247\u6bb5\uff08\u901a\u5e38\u6700\u591a\u51e0\u767e\u4e2a\u78b1\u57fa\u5bf9\uff09\uff0c\u8fd9\u4f7f\u5f97\u590d\u6742\u57fa\u56e0\u7ec4\u533a\u57df\u7684\u7ec4\u88c5\u548c\u5206\u6790\u66f4\u52a0\u51c6\u786e\u3002\u50cfThermo Fisher Scientific Ion Torrent Chef\/S5\u7cfb\u7edf\u6216Thermo Fisher Scientific Ion Torrent Genexus\u6d4b\u5e8f\u4eea\u8fd9\u6837\u7684\u77ed\u8bfb\u957f\u6d4b\u5e8f\u5e73\u53f0\uff0c\u53ef\u4ee5\u9ad8\u6548\u5730\u6d4b\u5e8f\u5927\u91cf\u77edDNA\u7247\u6bb5\uff0c\u975e\u5e38\u9002\u5408\u4e0e\u5168\u57fa\u56e0\u7ec4\u6d4b\u5e8f\u548c\u9776\u5411\u6d4b\u5e8f\u96c6\u6210\u5de5\u4f5c\u6d41\u7a0b\u3002\u4e0b\u88681\u6982\u8ff0\u4e86\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u6280\u672f\u5728\u591a\u79cd\u5e94\u7528\u4e2d\u7684\u4e00\u4e9b\u4f18\u52bf\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6bd4\u8f83\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u4f18\u52bf\u4e0e\u5e94\u7528\">\u6bd4\u8f83\u77ed\u8bfb\u957f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u4f18\u52bf\u4e0e\u5e94\u7528<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><\/th><th><strong>\u77ed\u8bfb\u957f<\/strong><\/th><th><strong>\u957f\u8bfb\u957f<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong><strong><strong>\u4f18\u52bf<\/strong><\/strong><\/strong><\/td><td>\u9ad8\u51c6\u786e\u6027<br>\u6210\u672c\u6548\u76ca<br>\u9ad8\u901a\u91cf<br>\u4f7f\u7528\u6807\u51c6\u57fa\u56e0\u7ec4DNA<\/td><td>\u66f4\u957f\u7684\u8bfb\u53d6\u957f\u5ea6<br>\u4e0e\u77ed\u8bfb\u6bb5\u76f8\u6bd4\uff0c\u53ef\u80fd\u63d0\u5347\u7ed3\u6784\u53d8\u5f02\u68c0\u6d4b\u80fd\u529b<br>\u53ef\u89e3\u6790\u590d\u6742\u533a\u57df<br>\u4f7f\u7528\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\uff08\u2265 40 kb\uff09*<\/td><\/tr><tr><td><strong><strong><strong>\u7ed3\u6784\u53d8\u5f02<\/strong><\/strong><\/strong><\/td><td>\u4ec5\u9650\u4e8e\u5c0f\u578b\u7ed3\u6784\u53d8\u5f02<\/td><td>\u5bf9\u5927\u89c4\u6a21\u57fa\u56e0\u7ec4\u6539\u53d8\u81f3\u5173\u91cd\u8981<\/td><\/tr><tr><td><strong><strong><strong><strong>\u5168\u65b0\u57fa\u56e0\u7ec4\u7ec4\u88c5<\/strong><\/strong><\/strong><\/strong><\/td><td>\u5bf9\u65b0\u57fa\u56e0\u7ec4\u7ec4\u88c5\u6548\u679c\u8f83\u5dee<\/td><td>\u5bf9\u4e8e\u4ece\u5934\u7ec4\u88c5\u57fa\u56e0\u7ec4\u81f3\u5173\u91cd\u8981<\/td><\/tr><tr><td><strong><strong><strong><strong>\u5355\u500d\u578b\u5206\u578b<\/strong><\/strong><\/strong><\/strong><\/td><td>\u5206\u578b\u80fd\u529b\u6709\u9650<\/td><td>\u786e\u5b9a\u957f\u8ddd\u79bb\u7684\u76f8\u4f4d\u5173\u7cfb<\/td><\/tr><tr><td><strong><strong><strong>\u8868\u89c2\u9057\u4f20\u5b66\u7814\u7a76<\/strong><\/strong><\/strong><\/td><td>\u8868\u89c2\u9057\u4f20\u5206\u6790\u6709\u9650<\/td><td>\u540c\u65f6\u8fdb\u884c\u9057\u4f20\u548c\u8868\u89c2\u9057\u4f20\u5206\u6790<\/td><\/tr><tr><td><strong><strong>SNP\u548c\u5c0f\u578b\u63d2\u5165\u7f3a\u5931\u68c0\u6d4b<\/strong><\/strong><\/td><td>\u975e\u5e38\u9002\u5408\u68c0\u6d4bSNP\u548c\u5c0f\u578b\u63d2\u5165\u7f3a\u5931<\/td><td>\u5bf9\u975e\u5e38\u5c0f\u7684\u53d8\u5f02\u6548\u679c\u8f83\u5dee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong><strong>*DNA\u7247\u6bb5\u5927\u5c0f\u7684\u8981\u6c42\u6839\u636e\u5e94\u7528\u548c\u5e73\u53f0\u6709\u5f88\u5927\u5dee\u5f02<\/strong><\/strong><\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u9ad8\u5206\u5b50\u91cf-hmw-dna\u5bf9\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u91cd\u8981\u6027\u662f\u4ec0\u4e48\">\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u5bf9\u957f\u8bfb\u957f\u6d4b\u5e8f\u7684\u91cd\u8981\u6027\u662f\u4ec0\u4e48\uff1f<\/h2>\n\n\n\n<p>\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\uff08HMW gDNA\uff09\u7528\u4e8e\u957f\u8bfb\u957f\u6d4b\u5e8f\u4ee5\u53ca\u5176\u4ed6\u9700\u8981\u5927\u5206\u5b50DNA\u7684\u5e94\u7528\uff0c\u5982\u5149\u5b66\u57fa\u56e0\u7ec4\u56fe\u8c31\u3002\u7531\u4e8e\u53bb novo \u6d4b\u5e8f\u548c\u957f\u8bfb\u957f\u6d4b\u5e8f\u5e94\u7528\u9700\u8981\u9ad8\u5206\u5b50\u91cfDNA\u7684\u590d\u6742\u6027\uff0c\u5bf9\u4e8e\u5927\u591a\u6570\u5e94\u7528\u6765\u8bf4\uff0c\u62e5\u6709\u9ad8\u8d28\u91cf\u4e14\u5927\u4e8e40kb\u7684\u5206\u79bbDNA\u81f3\u5173\u91cd\u8981\u3002\u5728\u67d0\u4e9b\u60c5\u51b5\u4e0b\uff0c\u62e5\u6709\u5927\u4e8e100kb\u7684DNA\u53ef\u4ee5\u83b7\u5f97\u66f4\u4f18\u7ed3\u679c\u3002\u8bc4\u4f30\u6216\u5b9e\u9a8c\u5ba4\u751f\u6210\u8fc7\u7a0b\u4e2d\uff0c\u517c\u987e\u901a\u91cf\u9700\u6c42\u3001\u8d28\u91cf\u548c\u57fa\u56e0\u7ec4\u5927\u5c0f\u53ef\u80fd\u4f1a\u5e26\u6765\u56f0\u96be\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u9ad8\u5206\u5b50\u91cfdna\u63d0\u53d6\">\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6<\/h2>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A36626\" target=\"_blank\" rel=\"noreferrer noopener\">Applied Biosystems\u2122 MagMAX\u2122 HMW DNA Kit<\/a> \u65e8\u5728\u83b7\u53d6\u9002\u7528\u4e8eOxford Nanopore\u6216PacBio\u7b49\u5236\u9020\u5546\u7684\u957f\u8bfb\u957f\u6d4b\u5e8f\u5e73\u53f0\u6240\u9700\u7684\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\u3002MagMAX HMW DNA\u8bd5\u5242\u76d2\u7ecf\u8fc7\u4f18\u5316\uff0c\u53ef\u4ece\u65b0\u9c9c\u6216\u51b7\u51bb\u5168\u8840\u3001\u57f9\u517b\u7ec6\u80de\u548c\u7ec4\u7ec7\u4e2d\u83b7\u5f97\u9ad8\u8d28\u91cf\u4ea7\u91cf\u548c\u6027\u80fd\u8868\u73b0\u3002<\/p>\n\n\n\n<p>\u8be5\u8bd5\u5242\u76d2\u91c7\u7528\u78c1\u73e0\u6280\u672f\uff0c\u5e76\u9488\u5bf9\u624b\u52a8\u5206\u79bb\u6d41\u7a0b\u6216\u4f7f\u7528Thermo Fisher Scientific KingFisher\u2122\u7eaf\u5316\u4eea\u81ea\u52a8\u5316\u6d41\u7a0b\u8fdb\u884c\u4e86\u4f18\u5316\uff0c\u5b9e\u73b0\u4e86\u6837\u672c\u901a\u91cf\u548c\u5b9e\u9a8c\u5ba4\u81ea\u52a8\u5316\u9700\u6c42\u7684\u7075\u6d3b\u6027\u3002<\/p>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/automated-purification-extraction\/automated-magmax-kits-nucleic-acid-extraction\/high-molecular-weight-dna-extraction.html\" target=\"_blank\" rel=\"noreferrer noopener\">MagMAX HMA DNA\u8bd5\u5242\u76d2\u7684\u6027\u80fd\u6570\u636e\u53ef\u5728\u7ebf\u83b7\u53d6<\/a>\u5305\u62ecDNA\u4ea7\u91cf\u3001\u8d28\u91cf\u3001\u7247\u6bb5\u5927\u5c0f\u4ee5\u53ca\u6309\u6837\u672c\u7c7b\u578b\u8fdb\u884c\u7684\u7247\u6bb5\u56de\u6536\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6ac9084f6dcdc&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6ac9084f6dcdc\" class=\"aligncenter size-medium wp-lightbox-container\"><img decoding=\"async\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/Picture14-300x253.png\" alt=\"\" class=\"wp-image-4965\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"\u653e\u5927\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"state.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><figcaption class=\"wp-element-caption\"><strong>MagMAX HMW DNA\u8bd5\u5242\u76d2<\/strong>\u80fd\u591f\u5728\u4e0d\u52302\u5c0f\u65f6\u5185\uff0c\u901a\u8fc7\u624b\u52a8\u548cKingFisher\u4eea\u5668\u81ea\u52a8\u5316\u6d41\u7a0b\uff0c\u7a33\u5b9a\u5206\u79bb\u5927\u4e8e100kb\u7684\u9ad8\u5206\u5b50\u91cfDNA\u7247\u6bb5\u3002<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e86\u89e3\u5e38\u89c1\u7684\u9ad8\u5206\u5b50\u91cfdna\u63d0\u53d6\u6311\u6218\">\u4e86\u89e3\u5e38\u89c1\u7684\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u6311\u6218<\/h2>\n\n\n\n<p>\u4ee5\u4e0b\u662f\u4e00\u4e9b\u5728\u5206\u79bb\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\u65f6\u53ef\u80fd\u9047\u5230\u7684\u6311\u6218\u793a\u4f8b\u3002\u6211\u4eec\u63d0\u4f9b\u4e86\u53ef\u80fd\u7684\u89e3\u51b3\u65b9\u6848\uff0c\u4ee5\u5e2e\u52a9\u63d0\u5347\u63d0\u53d6\u8d28\u91cf\u3001\u6548\u7387\u53ca\u540e\u7eed\u5e94\u7528\u4e2d\u7684\u8868\u73b0\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-\u4ea7\u91cf\u4f4e\u7684\u6837\u54c1\">1. \u4ea7\u91cf\u4f4e\u7684\u6837\u54c1<\/h3>\n\n\n\n<p>MagMAX HMW DNA\u8bd5\u5242\u76d2\u8bbe\u8ba1\u7528\u4e8e\u4ece200uL\u65b0\u9c9c\/\u51b7\u51bb\u5168\u8840\u30011 X 106\u4e2a\u7ec6\u80de\u4ee5\u53ca\u6700\u591a8mg\u7ec4\u7ec7\u4e2d\u83b7\u5f97\u81f3\u5c113\u5fae\u514b\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\u3002A260\/280\u548c260\/230\u6bd4\u503c\u5927\u4e8e1.8\u4e3a\u6700\u4f73\uff0c\u4ee5\u786e\u4fdd\u86cb\u767d\u8d28\u548c\u6c61\u67d3\u7269\u643a\u5e26\u6700\u5c0f\u5316\u3002<\/p>\n\n\n\n<p>\u4f4e\u4ea7\u91cf\u548c\u7eaf\u5ea6\u53ef\u80fd\u7531\u4e0b\u8ff0\u6240\u6709\u6837\u672c\u7c7b\u578b\u4e2d\u7684\u591a\u79cd\u539f\u56e0\u9020\u6210\uff0c\u8be6\u89c1\u4e0b\u6587\u8bf4\u660e\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u6240\u6709\u6837\u672c\u7c7b\u578b\u7684\u4ea7\u91cf\u8f83\u4f4e\">\u6240\u6709\u6837\u672c\u7c7b\u578b\u7684\u4ea7\u91cf\u8f83\u4f4e<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-dna\u6837\u54c1\u5728\u5de5\u4f5c\u6d41\u7a0b\u4e2d\u4e22\u5931\">\u53ef\u80fd\u539f\u56e0\uff1aDNA\u6837\u54c1\u5728\u5de5\u4f5c\u6d41\u7a0b\u4e2d\u4e22\u5931\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u5982\u679c\u8fdb\u884c\u624b\u52a8\u5206\u79bb\uff0c\u79fb\u6db2\u5668\u5438\u5934\u53ef\u80fd\u4f1a\u7559\u4e0b\u5fae\u91cf\u6837\u54c1\u3002\u5728\u4e22\u5f03\u524d\u8bf7\u52a1\u5fc5\u68c0\u67e5\u79fb\u6db2\u5668\u5438\u5934\u3002\u5728\u4f7f\u7528\u624b\u52a8\u6d41\u7a0b\u8fdb\u884c\u5206\u79bb\u65f6\uff0c\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA\u5728\u6d17\u6da4\u6b65\u9aa4\u4e2d\u53ef\u80fd\u4f1a\u7f20\u7ed5\u5728\u5438\u5934\u4e0a\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-\u6df7\u5408\u4e0d\u5145\u5206\">\u53ef\u80fd\u539f\u56e0\uff1a\u6df7\u5408\u4e0d\u5145\u5206\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u5982\u679c\u5728\u88c2\u89e3\/\u7ed3\u5408\u6216\u6d17\u6da4\u6b65\u9aa4\u4e2d\u89c2\u5bdf\u5230\u5927\u6bb5\u57fa\u56e0\u7ec4DNA\u7f20\u7ed5\u5728\u78c1\u73e0\u4e0a\uff0c\u5728\u4f7f\u7528\u624b\u52a8\u6d41\u7a0b\u65f6\uff0c\u8bf7\u52a1\u5fc5\u7528\u5e38\u89c4\u5b54\u5f84\u7684\u79fb\u6db2\u5668\u5438\u5934\u5c06\u5176\u6253\u6563\u3002\u5c06\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4DNA-\u78c1\u73e0\u56e2\u6df7\u54085-10\u6b21\u5373\u53ef\uff0c\u907f\u514d\u8fc7\u5ea6\u6df7\u5408\u4ee5\u9632\u6b62\u8fc7\u5ea6\u526a\u5207\u3002\u5efa\u8bae\u4f7f\u7528KingFisher\u7eaf\u5316\u4eea\u4e0a\u7684\u81ea\u52a8\u5316\u6d41\u7a0b\uff0c\u4ee5\u6d88\u9664\u6df7\u5408\u4e00\u81f4\u6027\u65b9\u9762\u7684\u4eba\u4e3a\u9519\u8bef\u3002KingFisher\u7eaf\u5316\u4eea\u5df2\u9a8c\u8bc1\u80fd\u4ee5\u7528\u6237\u8bf4\u660e\u4e2d\u7684\u65e2\u5b9a\u6df7\u5408\u901f\u5ea6\u5b9e\u73b0\u6700\u4f73\u6027\u80fd\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u53ef\u80fd\u539f\u56e0\uff1a\u78c1\u73e0\u8fc7\u5ea6\u5e72\u71e5\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u5982\u679c\u78c1\u73e0\u572850\u00b0C\u4e0b\u5e72\u71e52\u5206\u949f\u540e\u51fa\u73b0\u88c2\u7eb9\uff0c\u5efa\u8bae\u5728\u4f7f\u7528\u624b\u52a8\u6d41\u7a0b\u65f6\u4e8e\u5ba4\u6e29\u4e0b\u7a7a\u6c14\u5e72\u71e5\u78c1\u73e02\u5206\u949f\u3002\u53ef\u8003\u8651\u91c7\u7528\u4f18\u5316\u540e\u7684KingFisher\u7eaf\u5316\u534f\u8bae\uff0c\u4ee5\u6d88\u9664\u5e72\u71e5\u4e00\u81f4\u6027\u65b9\u9762\u7684\u4eba\u4e3a\u9519\u8bef\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-\u6837\u54c1\u6d88\u5316\u4e0d\u8db3\">\u53ef\u80fd\u539f\u56e0\uff1a\u6837\u54c1\u6d88\u5316\u4e0d\u8db3\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u8bf7\u6839\u636eMagMAX HMW\u8bd5\u5242\u76d2\u7528\u6237\u6307\u5357\u4e2d\u9488\u5bf9\u6bcf\u79cd\u5177\u4f53\u6837\u54c1\u6d88\u5316\u9700\u6c42\u7684\u5efa\u8bae\u64cd\u4f5c\uff0c\u907f\u514d\u6837\u54c1\u8fc7\u91cf\u3002\u8bf7\u6ce8\u610f\uff0cMagMAX HMW\u8bd5\u5242\u76d2\u4e2d\u7684\u589e\u5f3a\u6eb6\u6db2\u53ef\u4ee5\u63d0\u5347\u86cb\u767d\u9176K\u7684\u6d3b\u6027\uff0c\u4f46\u5728\u4f4e\u6e29\u4e0b\u4e5f\u53ef\u80fd\u53d1\u751f\u6c89\u6dc0\u3002\u5982\u679c\u589e\u5f3a\u6eb6\u6db2\u51fa\u73b0\u6c89\u6dc0\uff0c\u8bf7\u786e\u4fdd\u5728\u4f7f\u7528\u524d\u4e8e37\u00b0C\u5b75\u80b2\uff0c\u4ee5\u4fdd\u8bc1\u6700\u5927\u6548\u7387\u3002\u5efa\u8bae\u4f7f\u7528KingFisher\u7eaf\u5316\u4eea\u8fdb\u884c\u5206\u79bb\uff0c\u56e0\u4e3a\u5176\u52a0\u70ed\u677f\u53ef\u63d0\u4f9b\u6301\u7eed\u4e14\u5145\u8db3\u7684\u70ed\u91cf\uff0c\u4ece\u800c\u786e\u4fdd\u6309\u7167\u9a8c\u8bc1\u8fc7\u7684MagMAX HMW\u6d41\u7a0b\u83b7\u5f97\u9002\u5f53\u6d88\u5316\u6548\u679c\u3002<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5168\u8840\u6837\u54c1\u4ea7\u7387\u4f4e\">\u5168\u8840\u6837\u54c1\u4ea7\u7387\u4f4e<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-\u8840\u6db2\u4e2d\u542b\u6709\u8840\u7ea2\u86cb\u767d\u548c\u5176\u4ed6\u86cb\u767d\u8d28-\u8fd9\u4e9b\u6210\u5206\u96be\u4ee5\u5f7b\u5e95\u6d17\u51c0\u548c\u5145\u5206\u6d88\u5316\">\u53ef\u80fd\u539f\u56e0\uff1a\u8840\u6db2\u4e2d\u542b\u6709\u8840\u7ea2\u86cb\u767d\u548c\u5176\u4ed6\u86cb\u767d\u8d28\uff0c\u8fd9\u4e9b\u6210\u5206\u96be\u4ee5\u5f7b\u5e95\u6d17\u51c0\u548c\u5145\u5206\u6d88\u5316\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u5728\u624b\u52a8\u64cd\u4f5c\u6d41\u7a0b\u4e2d\uff0c\u7b2c\u4e09\u6b21\u6d17\u6da4\u540e\u52a1\u5fc5\u5c06\u6837\u54c1\u8f6c\u79fb\u5230\u65b0\u7684\u7ba1\u4e2d\uff0c\u4ee5\u9632\u6b62\u6c61\u67d3\u7269\u968f\u6d17\u8131\u6db2\u5e26\u5165\u3002\u5efa\u8bae\u4f7f\u7528KingFisher\u7eaf\u5316\u4eea\u4e0a\u7684\u81ea\u52a8\u5de5\u4f5c\u6d41\u7a0b\uff0c\u8fd9\u4e0d\u4ec5\u80fd\u51cf\u5c11\u56e0\u64cd\u4f5c\u8005\u5f15\u5165\u7684\u6837\u54c1\u95f4\u4ea4\u53c9\u6c61\u67d3\u98ce\u9669\uff0c\u8fd8\u80fd\u5e2e\u52a9\u786e\u4fdd\u4ece\u7ed3\u5408\u3001\u6d17\u6da4\u3001\u5e72\u71e5\u5230\u6838\u9178\u6d17\u8131\u8fc7\u7a0b\u7684\u4e00\u81f4\u6027\u5206\u79bb\u6548\u679c\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u53ef\u80fd\u539f\u56e0\uff1a\u8d77\u59cb\u6837\u54c1\u767d\u7ec6\u80de\uff08WBC\uff09\u8ba1\u6570\u8f83\u4f4e\u6216\u8d77\u59cb\u6837\u54c1\u5df2\u51dd\u5757<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u767d\u7ec6\u80de\u8ba1\u6570\u4f4e\u610f\u5473\u7740\u7528\u4e8eDNA\u63d0\u53d6\u7684\u7ec6\u80de\u6570\u91cf\u8f83\u5c11\uff0c\u4ece\u800c\u5bfc\u81f4\u603b\u4f53DNA\u4ea7\u91cf\u964d\u4f4e\u3002\u8840\u6db2\u51dd\u5757\u4f1a\u4f7f\u6838\u9178\uff0c\u5c24\u5176\u662f\u9ad8\u5206\u5b50\u91cf\u57fa\u56e0\u7ec4\u7ed3\u6784\u96be\u4ee5\u5206\u79bb\u3002\u4e3a\u907f\u514d\u8840\u6db2\u51dd\u5757\uff0c\u8bf7\u4fdd\u6301\u6700\u4f73\u5b58\u50a8\u6761\u4ef6\u3001\u4f7f\u7528\u8840\u6db2\u7a33\u5b9a\u5242\uff08\u5982K2EDTA\uff09\uff0c\u5e76\u907f\u514d\u5728\u5904\u7406\u524d\u8fc7\u5ea6\u6df7\u5408\u6837\u54c1\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u57f9\u517b\u7ec6\u80de\u6837\u54c1\u4ea7\u91cf\u4f4e\">\u57f9\u517b\u7ec6\u80de\u6837\u54c1\u4ea7\u91cf\u4f4e<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-\u5206\u79bb\u8d85\u8fc7100\u4e07\u57f9\u517b\u7ec6\u80de\"><strong><u><br><\/u><\/strong>\u53ef\u80fd\u539f\u56e0\uff1a\u5206\u79bb\u8d85\u8fc7100\u4e07\u57f9\u517b\u7ec6\u80de<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>MagMAX HMW DNA\u8bd5\u5242\u76d2\u7ecf\u8fc7\u4f18\u5316\uff0c\u53ef\u5904\u7406\u6700\u591a100\u4e07\u57f9\u517b\u7ec6\u80de\u3002\u5982\u679c\u5c1d\u8bd5\u5904\u7406\u8d85\u8fc7100\u4e07\u57f9\u517b\u7ec6\u80de\uff0c\u5efa\u8bae\u5c06\u6240\u6709\u7ec4\u5206\u7684\u8bd5\u5242\u4f53\u79ef\u6309\u7ebf\u6027\u6bd4\u4f8b\u589e\u52a0\u3002\u5728\u624b\u52a8\u64cd\u4f5c\u6d41\u7a0b\u4e2d\uff0c\u8bf7\u786e\u4fdd\u4f7f\u7528\u9002\u5f53\u7684\u5de5\u4f5c\u6eb6\u6db2\u5bb9\u5668\uff0c\u4ee5\u5bb9\u7eb3\u6240\u7528\u8bd5\u5242\u4f53\u79ef\u3002\u5bf9\u4e8e\u81ea\u52a8\u5316KingFisher\u64cd\u4f5c\u6d41\u7a0b\uff0c\u5efa\u8bae\u5229\u7528 <a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/life-science\/download-bindit-software-kingfisher-instruments.html?erpType=Global_E1\">BindIt\u8f6f\u4ef6<\/a>(\u7528\u4e8eKingFisher Flex\u7eaf\u5316\u7cfb\u7edf\u3001KingFisher Duo Prime\u7eaf\u5316\u7cfb\u7edf)\u6216<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/technical-resources\/software-downloads\/kingfisher-apex-bindix-software.html\">BindIx\u8f6f\u4ef6<\/a>(\u7528\u4e8eKingFisher Apex\u7eaf\u5316\u7cfb\u7edf)\uff0c\u4ee5\u53cd\u6620\u65b0\u7684\u5de5\u4f5c\u4f53\u79ef\u6761\u4ef6\u3002\u8bf7\u6ce8\u610f\uff0c96\u78c1\u5934\u6700\u5927\u5141\u8bb8\u4f53\u79ef\u4e3a1mL\uff0c\u800c24\u78c1\u5934\u6700\u5927\u5de5\u4f5c\u4f53\u79ef\u4e3a5mL\u3002Thermo Fisher Scientific\u5c1a\u672a\u9a8c\u8bc1\u8d85\u8fc7100\u4e07\u57f9\u517b\u7ec6\u80de\u6216\u66f4\u5927\u89c4\u6a21\u4f53\u79ef\u683c\u5f0f\u7684\u64cd\u4f5c\u6d41\u7a0b\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u7ec4\u7ec7\u6837\u54c1\u4ea7\u91cf\u4f4e\">\u7ec4\u7ec7\u6837\u54c1\u4ea7\u91cf\u4f4e<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\u53ef\u80fd\u539f\u56e0-\u6d88\u5316\u4e0d\u8db3\u53ef\u80fd\u5bfc\u81f4\u672a\u6d88\u5316\u7684\u7ec4\u7ec7\u5757\u5728\u6d17\u6da4\u6b65\u9aa4\u4e2d\u88ab\u5e26\u5165\u540e\u7eed\u64cd\u4f5c\"><br>\u53ef\u80fd\u539f\u56e0\uff1a\u6d88\u5316\u4e0d\u8db3\u53ef\u80fd\u5bfc\u81f4\u672a\u6d88\u5316\u7684\u7ec4\u7ec7\u5757\u5728\u6d17\u6da4\u6b65\u9aa4\u4e2d\u88ab\u5e26\u5165\u540e\u7eed\u64cd\u4f5c\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u8bf7\u52a1\u5fc5\u9075\u5faa\u7528\u6237\u6307\u5357\u4e2d\u5217\u51fa\u7684\u6d88\u5316\u64cd\u4f5c\u6d41\u7a0b\u3002\u4ece\u8d85\u8fc7\u63a8\u8350\u8d28\u91cf\u7684\u7ec4\u7ec7\u4e2d\u8fdb\u884c\u5206\u79bb\uff0c\u53ef\u80fd\u5bfc\u81f4\u6837\u54c1\u6d88\u5316\u4e0d\u5145\u5206\u3002\u5982\u679c\u624b\u52a8\u5206\u79bb\u9ad8\u5206\u5b50\u91cfDNA\uff0c\u5728\u52a0\u5165\u9884\u6d88\u5316\u6df7\u5408\u6db2\u540e\uff0c\u5c06\u8bd5\u7ba1\u5012\u7f6e5-10\u6b21\uff0c\u4ee5\u786e\u4fdd\u5728\u6d88\u5316\u524d\u6ca1\u6709\u7ec4\u7ec7\u5757\u5361\u5728\u7ba1\u76d6\u4e0a\u3002\u5728\u6d88\u5316\u8fc7\u7a0b\u4e2d\u9014\u68c0\u67e5\u8bd5\u7ba1\uff0c\u89c2\u5bdf\u662f\u5426\u6709\u672a\u6d88\u5316\u7684\u7ec4\u7ec7\u3002\u5982\u53d1\u73b0\u672a\u6d88\u5316\u7ec4\u7ec7\uff0c\u53ef\u4f7f\u7528\u6da1\u65cb\u4eea\u6df7\u5300\u3002\u5efa\u8bae\u8003\u8651\u4f7f\u7528KingFisher\u7eaf\u5316\u4eea\u4e0a\u7684\u81ea\u52a8\u5de5\u4f5c\u6d41\u7a0b\uff0c\u8fd9\u53ef\u80fd\u6709\u52a9\u4e8e\u66f4\u5747\u5300\u5730\u6d88\u5316\u6240\u7528\u6837\u54c1\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\" id=\"h-\"><\/h5>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-\u6d17\u8131\u6db2\u7c98\u7a20\u6216\u5448\u68d5\u8272\">2. \u6d17\u8131\u6db2\u7c98\u7a20\u6216\u5448\u68d5\u8272<\/h3>\n\n\n\n<p>\u5728\u6d17\u8131\u677f\uff08\u81ea\u52a8\u63d0\u53d6\uff09\u6216\u5c06\u6837\u54c1\u8f6c\u79fb\u5230\u65b0\u8bd5\u7ba1\u65f6\uff08\u624b\u52a8\u63d0\u53d6\uff09\uff0c\u53ef\u80fd\u4f1a\u89c2\u5bdf\u5230\u90e8\u5206\u78c1\u73e0\u6b8b\u7559\u3002\u4e00\u4e9b\u7ec4\u7ec7\uff0c\u5982\u813e\u810f\uff0c\u53ef\u80fd\u542b\u6709\u5927\u91cfDNA\uff0c\u4ece\u800c\u4ea7\u751f\u66f4\u7c98\u7a20\u6216\u5448\u68d5\u8272\u7684\u6d17\u8131\u6db2\u3002\u5c11\u91cf\u78c1\u73e0\u6b8b\u7559\u8fdb\u5165\u6d17\u8131\u6db2\u4e00\u822c\u4e0d\u4f1a\u5f71\u54cd\u540e\u7eed\u7684\u5206\u5b50\u5e94\u7528\u3002<\/p>\n\n\n\n<p>\u5982\u679c\u78c1\u73e0\u6b8b\u7559\u8fc7\u591a\u6216\u5bf9\u60a8\u7684\u540e\u7eed\u5e94\u7528\u9020\u6210\u6291\u5236\uff1a<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u53ef\u80fd\u539f\u56e0\uff1a\u6837\u54c1\u8f93\u5165\u91cf\u8fc7\u9ad8\u3002<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>MagMAX HMW DNA Kit\u7684\u5de5\u4f5c\u6d41\u7a0b\u8bf4\u660e\u5df2\u6309\u7167\u7528\u6237\u624b\u518c\u4e2d\u7684\u6bd4\u4f8b\u8fdb\u884c\u4e86\u4f18\u5316\u3002\u5f53\u4f7f\u7528\u8f83\u5c11\u6216\u8f83\u591a\u6837\u54c1\u65f6\uff0c\u8fd9\u4e9b\u6bd4\u4f8b\u53ef\u80fd\u4f1a\u53d7\u5230\u5f71\u54cd\uff0c\u5e76\u5bfc\u81f4\u6bd4\u4f8b\u4e0d\u8db3\uff0c\u5c24\u5176\u662f\u4e0e\u78c1\u73e0\u8868\u9762\u79ef\u76f8\u5173\uff0c\u8fd9\u53ef\u80fd\u5bfc\u81f4\u6d17\u8131\u6db2\u4e2d\u51fa\u73b0\u78c1\u73e0\u6b8b\u7559\u3002\u8bf7\u6839\u636e\u7528\u6237\u6307\u5357\u786e\u5b9a\u6bcf\u79cd\u6837\u54c1\u7c7b\u578b\u7684\u6700\u5927\u8f93\u5165\u91cf\u3002\u5982\u679c\u60a8\u7684\u6837\u54c1\u7c7b\u578b\u672a\u5217\u51fa\uff0c\u8bf7\u8003\u8651\u5148\u8fdb\u884c\u521d\u6b65\u6ef4\u5b9a\u5b9e\u9a8c\uff0c\u4ee5\u786e\u5b9a\u6700\u4f73\u8f93\u5165\u91cf\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">\u53ef\u80fd\u539f\u56e0\uff1a\u6d88\u5316\u4e0d\u5145\u5206<\/h5>\n\n\n\n<p><strong>\u89e3\u51b3\u65b9\u6848\uff1a<\/strong>\u786e\u4fdd\u6309\u7167\u7528\u6237\u6307\u5357\u4e2d\u6307\u5b9a\u7684\u987a\u5e8f\u6dfb\u52a0 MagMAX HMW DNA \u8bd5\u5242\u76d2\u4e2d\u7684\u6240\u6709\u7ec4\u5206\u3002\u5982\u679c\u64cd\u4f5c\u987a\u5e8f\u88ab\u8c03\u6574\u3001\u672a\u8fbe\u5230\u6240\u9700\u7684\u5145\u5206\u6df7\u5408\uff0c\u6216\u6d88\u5316\u52a0\u70ed\u4e0d\u5145\u5206\uff0c\u5219 DNA \u6d17\u8131\u6db2\u53ef\u80fd\u4f1a\u53d8\u5f97\u201c\u7c98\u7a20\u201d\u3001\u6d53\u539a\uff0c\u5e76\u4e14\u79fb\u6db2\u53ef\u80fd\u4f1a\u53d8\u5f97\u56f0\u96be\u3002\u5982\u679c\u6000\u7591\u6d88\u5316\u4e0d\u5b8c\u5168\uff0c\u8bf7\u8003\u8651\u5ef6\u957f\u6d88\u5316\u65f6\u95f4\u3002<\/p>\n\n\n\n<p>\u60a8\u53ef\u4ee5\u91c7\u53d6\u4ee5\u4e0b\u51e0\u6b65\u6765\u5e2e\u52a9\u51cf\u5c11\u6d17\u8131\u6db2\u7684\u7c98\u7a20\u5ea6\u6216\u78c1\u73e0\u6b8b\u7559\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4f7f\u7528\u78c1\u529b\u67b6\u53bb\u9664\u6d17\u8131\u6db2\u4e2d\u7684\u78c1\u73e0\u3002<\/strong><br>\u5c06\u6d17\u8131\u677f\u653e\u7f6e\u572896\u5b54\u78c1\u529b\u67b6\u4e0a\uff0c\u4ee5\u786e\u4fdd\u6240\u6709\u78c1\u73e0\u90fd\u88ab\u5438\u9644\u3002\u5c0f\u5fc3\u5730\u5c06\u6f84\u6e05\u7684\u4e0a\u6e05\u6db2\u8f6c\u79fb\u5230\u65b0\u768496\u6df1\u5b54\u677f\u6216\u5fae\u91cf\u79bb\u5fc3\u7ba1\u4e2d\u3002<\/li>\n\n\n\n<li><strong>\u786e\u4fdd\u5b8c\u5168\u6d88\u5316\u3002<\/strong><br>\u786e\u4fdd\u86cb\u767d\u9176K\u80fd\u591f\u5f7b\u5e95\u6d88\u5316\uff0c\u6709\u6548\u5206\u89e3\u86cb\u767d\u8d28\u3002\u5982\u6709\u9700\u8981\uff0c\u53ef\u6309\u7167\u624b\u518c\u534f\u8bae\u8fdb\u884c\u989d\u5916\u7684\u79bb\u677f\u86cb\u767d\u9176K\u6d88\u5316\u6b65\u9aa4\u3002<\/li>\n\n\n\n<li><strong>\u8bf7\u67e5\u9605\u7528\u6237\u534f\u8bae\u8bf4\u660e\u4e66\u3002<\/strong><br>\u5728\u5904\u7406\u9ad8DNA\u4ea7\u91cf\u7ec4\u7ec7\u65f6\uff0c\u8bf7\u9075\u5faa\u7528\u6237\u6307\u5357\u4e2d\u5173\u4e8e\u9002\u5f53\u7ec4\u7ec7\u8f93\u5165\u91cf\u7684\u5efa\u8bae\u3002<\/li>\n<\/ul>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-\u9ad8\u5206\u5b50\u91cfdna\u964d\u89e3\">3. \u9ad8\u5206\u5b50\u91cfDNA\u964d\u89e3<\/h3>\n\n\n\n<p>HMW DNA\u964d\u89e3\u7684\u4e00\u4e2a\u53ef\u80fd\u539f\u56e0\u5728\u4e8e\u8d77\u59cb\u6837\u672c\u6750\u6599\u3002<\/p>\n\n\n\n<p>\u8bf7\u6ce8\u610f\u8fc7\u5ea6\u6df7\u5408\u3001\u6837\u672c\u8d28\u91cf\u5dee\u3001\u6837\u672c\u5b8c\u5168\u6d88\u5316\uff0c\u6216\u4f7f\u7528\u7269\u7406\u673a\u68b0\u88c2\u89e3\u5bfc\u81f4\u56de\u6536\u7684DNA\u88ab\u7247\u6bb5\u5316\u7b49\u98ce\u9669\u3002\u8bf7\u8003\u8651\u4ee5\u4e0b\u4e8b\u9879\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u907f\u514d\u7528\u8840\u6e05\u79fb\u6db2\u7ba1\u6df7\u5408\u65b0\u9c9c\u5168\u8840\u6837\u672c\uff0c\u56e0\u4e3a\u8fd9\u53ef\u80fd\u4f1a\u5bfc\u81f4DNA\u526a\u5207\u3002\u76f8\u53cd\uff0c\u5e94\u8f7b\u8f7b\u98a0\u5012\u5168\u8840\u6837\u672c\u7ba1\u81f3\u5c115\u6b21\uff0c\u4ee5\u786e\u4fdd\u5145\u5206\u5747\u8d28\u540e\u518d\u8f6c\u79fb\u5230\u6837\u672c\u677f\u6216\u7ba1\u4e2d\u3002<\/li>\n\n\n\n<li>\u5bf9\u4e8e\u51b7\u51bb\u8840\u6db2\u6837\u672c\uff0c\u5e94\u9650\u5236\u5728\u4e00\u6b21\u51bb\u878d\u5faa\u73af\u5185\u3002<\/li>\n\n\n\n<li>\u5bf9\u4e8e\u7ec6\u80de\uff0c\u5728\u52a0\u5165MagMAX\u7ec6\u80de\u548c\u7ec4\u7ec7\u88c2\u89e3\u7f13\u51b2\u6db2\u540e\uff0c\u786e\u4fdd\u5b8c\u5168\u5747\u8d28\u5316\u3002<\/li>\n\n\n\n<li>\u5bf9\u4e8e\u7ec4\u7ec7\u6837\u672c\uff0c\u4e0d\u8981\u4f7f\u7528\u673a\u68b0\u7814\u78e8\u3002\u5e94\u91c7\u7528\u6e29\u548c\u7684\u9176\u6d88\u5316\uff08\u5982\u86cb\u767d\u9176K\uff09\u3002<\/li>\n\n\n\n<li>\u624b\u52a8\u5206\u79bb\u65f6\uff0c\u8bf7\u4ed4\u7ec6\u67e5\u9605\u7528\u6237\u6307\u5357\u4e2d\u5173\u4e8e\u79fb\u6db2\u5668\u5438\u5934\uff08\u666e\u901a\u4e0e\u5bbd\u5b54\uff09\u7684\u8bf4\u660e\u3002<\/li>\n\n\n\n<li>\u5c06\u6d17\u8131\u4ea7\u7269\u50a8\u5b58\u5728\u9002\u5b9c\u7684\u6e29\u5ea6\u4e0b\uff08\u77ed\u671f\u4e3a4\u00baC\uff0c\u82e548\u5c0f\u65f6\u5185\u4e0d\u8fdb\u884c\u5206\u6790\u5219\u957f\u671f\u4e3a-20\u00baC\uff09\u3002<\/li>\n\n\n\n<li>\u907f\u514d\u5bf9\u5206\u79bb\u51fa\u7684\u6838\u9178\u8fdb\u884c\u53cd\u590d\u51bb\u878d\u3002<\/li>\n<\/ul>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-hmw-dna\u63d0\u53d6\u5e38\u89c1\u95ee\u9898\u89e3\u7b54\">HMW DNA\u63d0\u53d6\u5e38\u89c1\u95ee\u9898\u89e3\u7b54<\/h2>\n\n\n\n<p><strong>HMW DNA\u5206\u79bb\u6d41\u7a0b\u6709\u54ea\u4e9b\u5e94\u7528\uff1f<\/strong><\/p>\n\n\n\n<p>HMW DNA\u5206\u79bb\u5177\u6709\u8bb8\u591a\u540e\u7eed\u5e94\u7528\uff0c\u5305\u62ec<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/automated-purification-extraction\/automated-magmax-kits-nucleic-acid-extraction\/high-molecular-weight-dna-extraction.html#cancer-genomics\">\u764c\u75c7\u57fa\u56e0\u7ec4\u5b66\u7814\u7a76<\/a>\u6d89\u53ca\u4f7f\u7528<a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/life-science\/cancer-research-ebook-access.html\">\u65e0\u7ec6\u80deDNA\uff08cfDNA\uff09\u4f5c\u4e3a\u751f\u7269\u6807\u5fd7\u7269<\/a>\u3002<\/p>\n\n\n\n<p><strong>\u54ea\u4e9b\u6837\u672c\u7c7b\u578b\u9002\u7528\u4e8eMagMAX HMW DNA\u8bd5\u5242\u76d2\uff1f<\/strong><\/p>\n\n\n\n<p>\u8be5\u8bd5\u5242\u76d2\u652f\u6301\u591a\u79cd\u8f93\u5165\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5168\u8840\uff08\u65b0\u9c9c\u6216\u51b7\u51bb\uff0c\u7ea6200\u202f\u00b5L\uff09<\/li>\n\n\n\n<li>\u57f9\u517b\u7ec6\u80de\uff08\u7ea61\u00d710^6\u4e2a\u7ec6\u80de\uff09<\/li>\n\n\n\n<li>\u7ec4\u7ec7\uff08\u59822\u20138\u202fmg\uff09<\/li>\n<\/ul>\n\n\n\n<p><strong>\u8be5\u8bd5\u5242\u76d2\u53ef\u4ee5\u4e0e\u81ea\u52a8\u5316\u7cfb\u7edf\u4e00\u8d77\u4f7f\u7528\u5417\uff1f<\/strong><\/p>\n\n\n\n<p>\u662f\u7684\uff0cMagMAX HMW DNA\u8bd5\u5242\u76d2\u517c\u5bb9KingFisher Duo Prime\u3001Flex\u548cApex\u7cfb\u7edf\u3002\u81ea\u52a8\u5316\u53ef\u5b9e\u73b0\u4e00\u81f4\u7684\u3001\u65e0\u9700\u4eba\u5de5\u5e72\u9884\u7684\u5de5\u4f5c\u6d41\u7a0b\uff0c\u8017\u65f6\u4e0d\u5230\u4e24\u5c0f\u65f6\u3002\u4e5f\u63d0\u4f9b\u624b\u52a8\u78c1\u6027\u67b6\u64cd\u4f5c\u534f\u8bae\u3002<\/p>\n\n\n\n<p><strong>MagMAX HMW DNA\u8bd5\u5242\u76d2\u6700\u591a\u53ef\u4ee5\u8fdb\u884c\u591a\u5c11\u6b21\u53cd\u5e94\uff1f<\/strong><\/p>\n\n\n\n<p>\u8be5\u8bd5\u5242\u76d2\u652f\u6301\u624b\u52a8\u548c\u81ea\u52a8\u5904\u7406\u5de5\u4f5c\u6d41\u7a0b\uff0c\u6700\u591a\u53ef\u8fdb\u884c100\u6b21\u6837\u54c1\u5236\u5907\u3002<\/p>\n\n\n\n<p><strong>MagMAX HMW DNA\u8bd5\u5242\u76d2\u4e0e\u5176\u4ed6\u4ea7\u54c1\u76f8\u6bd4\u5982\u4f55\uff1f<\/strong><\/p>\n\n\n\n<p>\u5728\u76f4\u63a5\u5bf9\u6bd4\u4e2d\uff0cMagMAX HMW\u8bd5\u5242\u76d2\u4ece\u5168\u8840\u4e2d\u83b7\u5f97\u7684\u4ea7\u91cf\u4e0e\u5e02\u573a\u4e0a\u7684\u5176\u4ed6\u4ea7\u54c1\u76f8\u6bd4\u5177\u6709\u7ade\u4e89\u529b\u6216\u8868\u73b0\u51fa\u8272\uff0c\u5c24\u5176\u662f\u5728\u7ea6200\u5fae\u5347\u8840\u6db2\u4f53\u79ef\u65f6\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/Picture15.png\"><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/life-in-the-lab\/wp-content\/uploads\/sites\/10\/2025\/09\/Picture15.png\" alt=\"\" class=\"wp-image-4966\" \/><\/a><\/figure>\n<\/div>\n\n\n<p><strong>\u4f7f\u7528MagMAX HMW DNA\u63d0\u53d6\u8bd5\u5242\u76d2\u63d0\u53d6\u9700\u8981\u591a\u957f\u65f6\u95f4\uff1f<\/strong><\/p>\n\n\n\n<p>\u81ea\u52a8\u5316\u5de5\u4f5c\u6d41\u7a0b\u4e0b\uff0c\u63d0\u53d6\u901a\u5e38\u8017\u65f6\u4e0d\u52302\u5c0f\u65f6\u3002\u624b\u52a8\u64cd\u4f5c\u534f\u8bae\u540c\u6837\u5feb\u901f\u9ad8\u6548\u3002<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5173\u4e8ehmw\u63d0\u53d6\u4ee5\u53ca\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u66f4\u591a\u8d44\u6e90\">\u5173\u4e8eHMW\u63d0\u53d6\u4ee5\u53ca\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u66f4\u591a\u8d44\u6e90<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4ea7\u54c1\u89e3\u51b3\u65b9\u6848\uff1a<\/strong><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/automated-purification-extraction\/automated-magmax-kits-nucleic-acid-extraction\/high-molecular-weight-dna-extraction.html\">MagMAX HMW DNA\u63d0\u53d6\u8bd5\u5242\u76d2<\/a>\n<ul class=\"wp-block-list\">\n<li><strong>\u7528\u6237\u6307\u5357<\/strong>\u7528\u4e8e<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/LSG\/manuals\/MAN1001478-MagMAX-HMWDNA-UG.pdf\">\u63d0\u53d6\u8bd5\u5242\u76d2<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u81ea\u52a8\u5316\uff1a<\/strong><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/dna-rna-purification-analysis\/automated-purification-extraction\/kingfisher-systems.html\">KingFisher\u81ea\u52a8\u5316\u6837\u54c1\u7eaf\u5316\u548c\u63d0\u53d6\u7cfb\u7edf<\/a>\n<ul class=\"wp-block-list\">\n<li><strong>\u6f14\u793a\u7533\u8bf7<\/strong><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/global\/forms\/kingfisher-magnetic-particle-processors-tools.html\">\u81ea\u52a8\u5904\u7406\u7cfb\u7edf<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u4e86\u89e3\uff1a<\/strong><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/life-science\/sequencing.html\">\u6d4b\u5e8f<\/a><\/li>\n<\/ul>\n\n\n\n<p>##<\/p>\n\n\n\n<p><em>\u00a9 2025 Thermo Fisher Scientific Inc. \u4fdd\u7559\u6240\u6709\u6743\u5229\u3002\u9664\u975e\u53e6\u6709\u8bf4\u660e\uff0c\u6240\u6709\u5546\u6807\u5747\u4e3a Thermo Fisher Scientific \u53ca\u5176\u5b50\u516c\u53f8\u7684\u8d22\u4ea7\u3002\u5982\u6709\u8bf4\u660e\u3002<\/em><\/p>\n\n\n\n<p><em>\u4ec5\u4f9b\u79d1\u7814\u4f7f\u7528\u3002\u4e0d\u5f97\u7528\u4e8e\u8bca\u65ad\u7a0b\u5e8f\u3002<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u63d0\u53d6\u9ad8\u8d28\u91cf\u3001\u5b8c\u6574\u7684\u57fa\u56e0\u7ec4DNA\u662f\u8bb8\u591a\u540e\u7eed\u5206\u5b50\u5e94\u7528\u7684\u57fa\u7840\u6b65\u9aa4\u2014\u2014\u4f46\u5e76\u975e\u6240\u6709DNA\u90fd\u662f\u4e00\u6837\u7684\u3002\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09D<\/p>\n","protected":false},"author":1852,"featured_media":714,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[42],"division":[9],"class_list":{"0":"post-713","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-8","8":"tag-dna","9":"division-bid","10":"entry"},"_selected_authors":[968,992,994],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6\" \/>\n<meta property=\"og:description\" content=\"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-09T05:32:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-09T05:32:06+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"783\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"headline\":\"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6\",\"datePublished\":\"2026-03-09T05:32:04+00:00\",\"dateModified\":\"2026-03-09T05:32:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/\"},\"wordCount\":227,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/HMW-Blog-Image.jpg\",\"keywords\":[\"DNA\u63d0\u53d6\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#respond\"]}],\"accessibilityFeature\":[\"tableOfContents\"]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/\",\"name\":\"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/HMW-Blog-Image.jpg\",\"datePublished\":\"2026-03-09T05:32:04+00:00\",\"dateModified\":\"2026-03-09T05:32:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\"},\"description\":\"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/HMW-Blog-Image.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/HMW-Blog-Image.jpg\",\"width\":1200,\"height\":783},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/hmw-dna-extraction-101\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/8e7a640047c10da2b7107498ddb447d6\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/","og_locale":"zh_CN","og_type":"article","og_title":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6","og_description":"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-09T05:32:04+00:00","article_modified_time":"2026-03-09T05:32:06+00:00","og_image":[{"width":1200,"height":783,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg","type":"image\/jpeg"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"headline":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6","datePublished":"2026-03-09T05:32:04+00:00","dateModified":"2026-03-09T05:32:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/"},"wordCount":227,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg","keywords":["DNA\u63d0\u53d6"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#respond"]}],"accessibilityFeature":["tableOfContents"]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/","name":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg","datePublished":"2026-03-09T05:32:04+00:00","dateModified":"2026-03-09T05:32:06+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6"},"description":"\u4e86\u89e3\u7528\u4e8e\u957f\u8bfb\u957f\u548c\u77ed\u8bfb\u957f\u6d4b\u5e8f\u7684\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09DNA\u63d0\u53d6\u65b9\u6cd5\uff0c\u5e76\u63a2\u7d22\u9ad8\u5206\u5b50\u91cfDNA\u63d0\u53d6\u7684\u5e38\u89c1\u6545\u969c\u6392\u9664\u6280\u5de7\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image.jpg","width":1200,"height":783},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/hmw-dna-extraction-101\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u9ad8\u5206\u5b50\u91cfHMW DNA\u63d0\u53d6"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/8e7a640047c10da2b7107498ddb447d6","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":42,"label":"DNA\u63d0\u53d6"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/HMW-Blog-Image-1024x668.jpg",760,496,true],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":2,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":135,"filter":"raw","meta":[],"cat_ID":8,"category_count":135,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":42,"name":"DNA\u63d0\u53d6","slug":"dna%e6%8f%90%e5%8f%96","term_group":0,"term_taxonomy_id":42,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=713"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/713\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/714"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=713"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}