{"id":995,"date":"2026-03-19T05:18:31","date_gmt":"2026-03-19T05:18:31","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/?p=995"},"modified":"2026-04-22T21:59:30","modified_gmt":"2026-04-22T21:59:30","slug":"cell-counting-methods","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cell-counting-methods\/","title":{"rendered":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-part-1-\u7ec6\u80de\u8ba1\u6570\u65b9\u6cd5\u6982\u8ff0\"><strong>Part 1 \u7ec6\u80de\u8ba1\u6570\u65b9\u6cd5\u6982\u8ff0<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\"><strong>\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u8840\u7403\u8ba1\u6570\u677f\u548c\u53f0\u76fc\u84dd\u67d3\u8272\uff0c\u5c3d\u7ba1\u7ecf\u5178\u4f46\u8d39\u65f6\u8d39\u529b\uff0c\u4e14\u624b\u52a8\u8bef\u5dee\u5927\uff0c\u91cd\u590d\u6027\u6709\u9650\u3002\u9047\u5230\u6837\u672c\u6d53\u5ea6\u5f02\u5e38\uff0c\u7ed3\u679c\u7a33\u5b9a\u6027\u5f88\u5dee\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\">\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982Countess\u2122\u81ea\u52a8\u7ec6\u80de\u8ba1\u6570\u4eea\uff0c\u64cd\u4f5c\u7b80\u4fbf\uff0c\u89e3\u653e\u53cc\u624b\uff0c\u4f53\u79ef\u5c0f\u5de7\u53ef\u4ee5\u653e\u8fdb\u8d85\u51c0\u53f0\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\">\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u5f0f\u7ec6\u80de\u4eea\uff1a<\/strong>&nbsp;\u4f7f\u7528\u6ce8\u5c04\u6cf5\u4f5c\u4e3a\u52a8\u529b\u6765\u6e90\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\uff0c\u5982Attune\u2122 NxT\u6d41\u5f0f\u7ec6\u80de\u4eea\uff0c\u80fd\u591f\u5bf9\u6837\u672c\u4f53\u79ef\u8fdb\u884c\u7cbe\u786e\u63a7\u5236\uff0c\u65e0\u9700\u4f9d\u8d56\u8ba1\u6570\u5fae\u7403\u8fdb\u884c\u7ec6\u80de\u6d53\u5ea6\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u5f0f\u7ec6\u80de\u4eea+\u8ba1\u6570\u5fae\u7403\uff1a<\/strong>&nbsp;\u5bf9\u4e8e\u65e0\u6cd5\u7cbe\u786e\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\uff0c\u901a\u8fc7\u5f15\u5165\u8ba1\u6570\u5fae\u7403\uff0c\u53ef\u4ee5\u5b9e\u73b0\u9ad8\u6548\u4e14\u51c6\u786e\u7684\u7ec6\u80de\u6d53\u5ea6\u8ba1\u7b97\uff0c\u5e76\u7ed3\u5408\u6297\u4f53\u67d3\u8272\uff0c\u5b9e\u73b0\u4e0d\u540c\u7ec6\u80de\u4e9a\u7fa4\u7684\u6d53\u5ea6\u6d4b\u5b9a\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-part-2-\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u539f\u7406-\u5fae\u7403\u5982\u4f55\u6210\u4e3a-\u6807\u5c3a\"><strong>Part 2 \u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u539f\u7406\u2014\u2014\u5fae\u7403\u5982\u4f55\u6210\u4e3a\u201c\u6807\u5c3a\u201d\uff1f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8ba1\u6570\u5fae\u7403\u662f\u4e00\u79cd\u6d53\u5ea6\u51c6\u786e\u7684\u5fae\u7403\u60ac\u6db2\uff0c\u8fd9\u4e9b\u5fae\u7403\u901a\u5e38\u5728\u5e7f\u6cdb\u7684\u6fc0\u53d1\u6ce2\u957f\u548c\u53d1\u5c04\u6ce2\u957f\u8303\u56f4\u5185\u90fd\u80fd\u53d1\u51fa\u660e\u4eae\u7684\u8367\u5149\u3002\u5728\u6837\u672c\u4e2d\u52a0\u5165\u4e00\u5b9a\u4f53\u79ef\u5df2\u77e5\u6d53\u5ea6\u7684\u8ba1\u6570\u5fae\u7403\uff0c\u6df7\u5408\u5747\u5300\u540e\u4e0a\u673a\uff0c\u6d41\u5f0f\u68c0\u6d4b\u5fae\u7403\u4e0e\u7ec6\u80de\u4fe1\u53f7\uff0c\u533a\u5206\u7ec6\u80de\u4e9a\u7fa4\u4e0e\u5fae\u7403\uff08\u56fe1\uff09\u4e4b\u540e\uff0c\u901a\u8fc7\u516c\u5f0f<strong>\u7ec6\u80de\u6d53\u5ea6(cells\/\u00b5L) = (\u7ec6\u80deevents\u6570 \/ \u5fae\u7403events\u6570) \u00d7 (\u5fae\u7403\u6d53\u5ea6 * \u6dfb\u52a0\u7684\u5fae\u7403\u4f53\u79ef \/ \u7ec6\u80de\u4f53\u79ef) = (\u7ec6\u80deevents\u6570 \/ \u5fae\u7403events\u6570) \u00d7 (\u5fae\u7403\u603b\u6570 \/ \u7ec6\u80de\u4f53\u79ef)<\/strong>\uff0c\u8ba1\u7b97\u5f97\u5230\u7ec6\u80de\u6d53\u5ea6\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em>\u6ce8\u610f\uff1a<\/em><\/strong><em>\u4e0a\u6837\u6837\u54c1\u4e2d\u989d\u5916\u52a0\u5165\u7684\u67d3\u8272\u7f13\u51b2\u6db2\u53ca\u5176\u4ed6\u7f13\u51b2\u6db2\u4f53\u79ef\u65e0\u9700\u5305\u542b\u5728\u8ba1\u7b97\u4e2d\uff0c\u4f8b\u598250 \u00b5L\u7684\u7ec6\u80de\u6837\u672c\u548c50 \u00b5L\u7684\u5fae\u7403\u52a0\u5165\u5230300 \u00b5L\u7684PBS\u4e2d\u4e0a\u673a\u8ba1\u6570\uff0c\u7528\u4e8e\u8ba1\u7b97\u7684\u7ec6\u80de\u4f53\u79ef\u4e3a50 \u00b5L\uff0c\u800c\u4e0d\u662f\u4e0a\u6837\u6837\u54c1\u7684\u603b\u4f53\u79ef400 \u00b5L\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u5f0f\u8ba1\u6570\u5fae\u7403\u4f7f\u7528\u7684\u7b80\u5355\u6d41\u7a0b\uff1a<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"694\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173611@2x-694x1024.png\" alt=\"\" class=\"wp-image-996\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173611@2x-694x1024.png 694w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173611@2x-203x300.png 203w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173611@2x-768x1134.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173611@2x.png 886w\" sizes=\"auto, (max-width: 694px) 100vw, 694px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e3e\u4e2a\u4f8b\u5b50\uff1a<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"770\" height=\"682\" src=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png\" alt=\"\" class=\"wp-image-997\" style=\"width:418px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png 770w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x-300x266.png 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x-768x680.png 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x-310x274.png 310w\" sizes=\"auto, (max-width: 770px) 100vw, 770px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u56fe1 CD4-FITC-A vs SSC-A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7ec6\u80de\u6837\u672c\u4f53\u79ef\uff1a<\/strong>50 \u00b5L\uff0c\u5fae\u7403\u603b\u6570\uff1a56,500 \u4e2a\uff08\u53ef\u4ee5\u901a\u8fc7<strong>\u5fae\u7403\u6d53\u5ea6*\u6dfb\u52a0\u7684\u5fae\u7403\u4f53\u79ef<\/strong>\u8ba1\u7b97\u5f97\u51fa\uff09\u3002\u901a\u8fc7\u6d41\u5f0f\u5206\u6790\u4e4b\u540e(\u56fe1)\u53ef\u4ee5\u5f97\u5230CD4+&nbsp;<strong>\u7ec6\u80deevents\u6570<\/strong>\u4e3a3,792\uff0c\u5fae\u7403events\u6570\u4e3a10,990\uff0c\u6240\u4ee5\u6839\u636e\u516c\u5f0f\u8ba1\u7b97\u5f97\u5230CD4+\u7ec6\u80de\u6d53\u5ea6\u4e3a390 cells\/\u00b5L\u3002CD4+ \u7ec6\u80de\u6d53\u5ea6 =<strong>&nbsp;(\u7ec6\u80deevents\u6570 \/ \u5fae\u7403events\u6570) \u00d7 (\u5fae\u7403\u603b\u6570 \/ \u7ec6\u80de\u4f53\u79ef)&nbsp;<\/strong>= (3792\/10990) \u00d7 (56500\/50) = 390 cells\/\u00b5L\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-part-3-\u6d41\u5f0f\u8ba1\u6570\u5fae\u7403\u7684\u4f18\u52bf\"><strong>Part 3 \u6d41\u5f0f\u8ba1\u6570\u5fae\u7403\u7684\u4f18\u52bf<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u591a\u53c2\u6570\u5206\u6790\uff1a<\/strong>\u4e00\u6b21\u5b9e\u9a8c\u5373\u53ef\u5b8c\u6210\u7ec6\u80de\u8ba1\u6570\u3001\u6d3b\u6027\u6d4b\u91cf\u548c\u8868\u578b\u5206\u6790\u3002<\/li>\n\n\n\n<li><strong>\u4f4e\u6d53\u5ea6\u6837\u672c\u5904\u7406\uff1a<\/strong>\u5bf9\u4e8e\u7a00\u6709\u6837\u672c\uff0c\u5373\u4f7f\u9776\u7ec6\u80de\u6570\u91cf\u6781\u5c11\uff0c\u4e5f\u80fd\u51c6\u786e\u8ba1\u6570\u3002<\/li>\n\n\n\n<li><strong>\u9ad8\u7cbe\u5ea6\uff1a<\/strong>\u901a\u8fc7\u516c\u5f0f\u8ba1\u7b97\uff0c\u964d\u4f4e\u4eba\u4e3a\u8bef\u5dee\u3002<\/li>\n\n\n\n<li><strong>\u591a\u79cd\u9897\u7c92\u8ba1\u6570\uff1a<\/strong>\u9002\u7528\u4e8e\u7ec6\u80de\u3001\u7ec6\u83cc\u3001\u75c5\u6bd2\u7b49\u4e0d\u540c\u5927\u5c0f\u9897\u7c92\u7684\u8ba1\u6570\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-part-4-\u6d41\u5f0f\u5fae\u7403\u5e38\u89c1\u95ee\u9898\"><strong>Part 4 \u6d41\u5f0f\u5fae\u7403\u5e38\u89c1\u95ee\u9898<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q<\/strong> \u6d41\u5f0f\u8ba1\u6570\u5fae\u7403\u8fd9\u4e48\u597d\uff0c\u5c31\u4e00\u70b9\u75db\u70b9\u90fd\u6ca1\u6709\u4e48\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u6bcf\u79cd\u8ba1\u6570\u65b9\u5f0f\u90fd\u6709\u5404\u81ea\u7684\u4f18\u70b9\u548c\u9650\u5236\u6027\uff0c\u5bf9\u4e8e\u6d41\u5f0f\u5fae\u7403\u8ba1\u6570\u6765\u8bf4\uff0c\u7279\u70b9\u975e\u5e38\u9c9c\u660e\uff0c\u4f46\u4e5f\u6709\u4e00\u4e9b\u56e0\u7d20\u4f1a\u5f71\u54cd\u8ba1\u6570\u7684\u51c6\u786e\u6027\uff0c\u5982\u7ec6\u80de\u60ac\u6db2\u548c\u5fae\u7403\u4f53\u79ef\u7684\u7cbe\u786e\u6027\uff0c\u65e0\u6cd5\u89c4\u907f\u6837\u672c\u5904\u7406\u4e2d\u7684\u6837\u672c\u635f\u5931\uff0c\u6d41\u5f0f\u5708\u95e8\u7684\u51c6\u786e\u6027\u7b49\u3002\u53e6\u5916\uff0c\u5fae\u7403\u7531\u4e8e\u6750\u8d28\u539f\u56e0\uff0c\u5bb9\u6613\u805a\u56e2\uff0c\u4f7f\u7528\u4e4b\u524d\u4e00\u822c\u8981\u5145\u5206\u6253\u6563\u6df7\u5300\uff0c\u8981\u4e25\u683c\u4fdd\u8bc1\u50a8\u5b58\u6e29\u5ea6\uff0c\u5fae\u7403\u6eb6\u6db2\u4e0d\u80fd\u51bb\u4f4f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q<\/strong> \u4e00\u822c\u6d41\u5f0f\u8ba1\u6570\u8981\u6536\u96c6\u5230\u591a\u5c11\u4e2a\u5fae\u7403\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u8fd9\u4e2a\u95ee\u9898\u6ca1\u6709\u4e00\u4e2a\u7edd\u5bf9\u7684\u7b54\u6848\uff0c\u4e5f\u8981\u770b\u9776\u7ec6\u80de\u7684\u7a00\u6709\u5ea6\u7b49\u5176\u4ed6\u5177\u4f53\u60c5\u51b5\u3002\u5e38\u89c4\u6765\u8bb2\uff0c\u81f3\u5c11\u8981\u6536\u96c6\u52301,000\u4e2a\u5fae\u7403\u3002\u4e00\u822c\u6765\u8bf4\uff0c\u4f1a\u5728\u8fd9\u4e2a\u57fa\u7840\u4e0a\u9002\u5f53\u63d0\u9ad8\u6536\u96c6\u7684\u5fae\u7403\u6570\u91cf\uff0c\u4f8b\u59825,000-10,000\u4e2a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q<\/strong> \u6211\u7684\u5fae\u7403\u6ca1\u6709\u529e\u6cd5\u8ddf\u7ec6\u80de\u540c\u65f6\u5448\u73b0\u5728\u540c\u4e00\u4e2a\u5206\u6790\u754c\u9762\u5185\u8be5\u600e\u4e48\u529e\u5462\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A<\/strong> \u4e3a\u4e86\u80fd\u591f\u8ba9\u9776\u7ec6\u80de\u7684\u8367\u5149\u5f3a\u5ea6\u66f4\u9002\u4e8e\u5206\u6790\uff0c\u5404\u4e2a\u8367\u5149\u901a\u9053\u7684\u7535\u538b\u90fd\u9700\u8981\u8fdb\u884c\u8c03\u8282\u8bbe\u7f6e\uff0c\u53ef\u80fd\u4f1a\u51fa\u73b0\u9776\u7ec6\u80de\u6bd4\u8f83\u5408\u9002\u7684\u7535\u538b\u5bf9\u4e8e\u5fae\u7403\u6765\u8bf4\u53ef\u80fd\u4f1a\u8fc7\u9ad8\uff0c\u4ece\u800c\u5bfc\u81f4\u9776\u7ec6\u80de\u548c\u5fae\u7403\u65e0\u6cd5\u5728\u540c\u4e00\u4e2a\u5206\u6790\u754c\u9762\u5185\u5448\u73b0\u3002\u4f46\u5b9e\u9645\u4e0a\uff0c\u53ea\u8981\u80fd\u591f\u51c6\u786e\u5206\u6790\u5230\u5fae\u7403\u7684events\u6570\u548c\u7ec6\u80de\u7684events\u6570\u5c31\u53ef\u4ee5\u5bf9\u7ec6\u80de\u6d53\u5ea6\u8fdb\u884c\u51c6\u786e\u8ba1\u7b97\uff0c\u800c\u5e76\u4e0d\u8981\u6c42\u5fae\u7403\u4e00\u5b9a\u8981\u548c\u9776\u7ec6\u80de\u5728\u540c\u4e00\u4e2a\u5206\u6790\u754c\u9762\u4e0b\u5448\u73b0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q<\/strong> \u6211\u4eec\u6709\u54ea\u4e9b\u5fae\u7403\u4ea7\u54c1\u53ef\u4ee5\u7528\u4e8e\u6d41\u5f0f\u8ba1\u6570\uff1f<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><td>CountBright Plus \u7edd\u5bf9\u8ba1\u6570\u5fae\u7403<\/td><td>CountBright \u7edd\u5bf9\u8ba1\u6570\u5fae\u7403<\/td><td>CountBright PlusReady Tubes<\/td><\/tr><tr><td>\u6837\u54c1\u7c7b\u578b<\/td><td>\u4efb\u610f\u7c7b\u578b,\u5305\u62ec\u5168\u8840\u548c\u88c2\u89e3\/\u672a\u7ecf\u6d17\u6da4\u7684\u5168\u8840<\/td><td>\u4efb\u610f\u7c7b\u578b,\u5305\u62ec\u5168\u8840\u548c\u88c2\u89e3\/\u672a\u7ecf\u6d17\u6da4\u7684\u5168\u8840<\/td><td>\u4efb\u610f\u7c7b\u578b,\u5305\u62ec\u5168\u8840\u548c\u88c2\u89e3\/\u672a\u7ecf\u6d17\u6da4\u7684\u5168\u8840<\/td><\/tr><tr><td>\u5fae\u7403\u5927\u5c0f<\/td><td>4\u5fae\u7c73<\/td><td>7\u5fae\u7c73<\/td><td>4\u5fae\u7c73<\/td><\/tr><tr><td>\u6fc0\u53d1(nm)<\/td><td>UV\u81f3808<\/td><td>UV\u81f3635<\/td><td>UV\u81f3808<\/td><\/tr><tr><td>\u53d1\u5c04(nm)<\/td><td>385\u81f3860<\/td><td>385\u81f3800<\/td><td>385\u81f3860<\/td><\/tr><tr><td>\u6d4b\u91cf\u53c2\u6570<\/td><td>\u7ec6\u80de\u6570\u91cf<\/td><td>\u7ec6\u80de\u6570\u91cf<\/td><td>\u7ec6\u80de\u6570\u91cf<\/td><\/tr><tr><td>\u8d27\u53f7<\/td><td>C36995<\/td><td>C36950<\/td><td>C40000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><td>LIVE\/DEAD BacLight\u7ec6\u83cc\u6d3b\u6027\u53ca\u8ba1\u6570\u8bd5\u5242\u76d2<\/td><td>ViroCheck NanoParticle Reference Kit<\/td><\/tr><tr><td>\u6837\u54c1\u7c7b\u578b<\/td><td>\u7ec6\u83cc\u6837\u54c1<\/td><td>\u4e9a\u5fae\u7c73\u6837\u54c1\uff0c\u5982\u75c5\u6bd2<\/td><\/tr><tr><td>\u5fae\u7403\u5927\u5c0f<\/td><td>6\u5fae\u7c73<\/td><td>200\/500\u7eb3\u7c73<\/td><\/tr><tr><td>\u6fc0\u53d1(nm)<\/td><td>\u4e0d\u53d1\u8367\u5149<\/td><td>UV\u81f3633<\/td><\/tr><tr><td>\u53d1\u5c04(nm)<\/td><td>N\/A<\/td><td>390\u81f3810<\/td><\/tr><tr><td>\u6d4b\u91cf\u53c2\u6570<\/td><td>\u6d3b\/\u6b7b\u7ec6\u83cc\u6570\u91cf<\/td><td>\u4e9a\u5fae\u7c73\u9897\u7c92\u5982\u75c5\u6bd2\u6570\u91cf<\/td><\/tr><tr><td>\u8d27\u53f7<\/td><td>L34856<\/td><td>V10425<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u5f0f\u7ec6\u80de\u672f<\/strong>\u662f\u91cd\u8981\u7684\u7ec6\u80de\u5206\u6790\u65b9\u6cd5\u5b66\uff0c<strong>\u8d5b\u9ed8\u98de\u4e16\u5c14\u79d1\u6280<\/strong>\u7684Gibco\u3001Invitrogen\u548cThermo Scientific\u4ea7\u54c1\u54c1\u724c\u53ef\u63d0\u4f9b\u4ece\u6d41\u5f0f\u4eea\u5668\u3001\u6297\u4f53\u8bd5\u5242\u5230\u4e30\u5bcc\u8d44\u6e90\u7684<strong>\u6d41\u5f0f\u6574\u4f53\u89e3\u51b3\u65b9\u6848<\/strong>\u3002\u5176\u4e2d<strong>Invitrogen eBioscience<\/strong>\u966a\u4f34\u7740\u6bcf\u4e00\u4ee3\u6d41\u5f0f\u79d1\u5b66\u5bb6\u548c\u6280\u672f\u4eba\u5458\u83b7\u5f97\u6210\u679c\u3001\u5171\u540c\u6210\u957f\uff0c\u8fd9\u4e9b\u5e74\u6765\u6211\u4eec\u4e00\u8d77\u89c1\u8bc1\u4ee5Anti-FoxP3\u4e3a\u4ee3\u8868\u7684\u6d41\u5f0f\u6297\u4f53\u6df1\u53d7\u559c\u7231\u3001\u66f4\u591a\u79cd\u7c7b\u7684\u6d41\u5f0f\u8367\u5149\u67d3\u6599\u6b23\u7136\u4e0a\u5e02\u4ee5\u53ca\u8d5b\u9ed8\u98de\u79d1\u5b66\u5bb6\u4eec\u7684\u5341\u5e74\u5982\u4e00\u65e5\u6280\u672f\u966a\u4f34\uff0c\u73b0\u5728\u6709\u7740\u66f4\u4e30\u5bcc\u7684\u4ea7\u54c1\u548c\u5de5\u5177\uff0c\u6ee1\u8db3\u9ad8\u6821\u7814\u7a76\u9662\u3001\u751f\u7269\u6280\u672f\u516c\u53f8\u3001\u836f\u4f01\u7b49\u4ece\u65e9\u671f\u57fa\u7840\u7814\u7a76\u5230\u4e34\u5e8a\u8f6c\u5316\u548c\u751f\u4ea7\u7b49\u4e0d\u540c\u9636\u6bb5\u7684\u9700\u6c42\uff0c\u52a0\u901f\u751f\u547d\u79d1\u5b66\u884c\u4e1a\u7684\u8fdb\u7a0b\u53d1\u5c55\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.thermofisher.cn\/cn\/zh\/home\/support\/contact-us-cn.html?icid=blog_banner#form\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg\" alt=\"contact and techincal support\" class=\"wp-image-387\" srcset=\"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1024x176.jpg 1024w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-768x132.jpg 768w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-1536x264.jpg 1536w, https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/02\/779-\u00d7-134-x3-1-2048x352.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Part 1 \u7ec6\u80de\u8ba1\u6570\u65b9\u6cd5\u6982\u8ff0 \u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5 \u4f7f\u7528\u8840\u7403\u8ba1\u6570\u677f\u548c\u53f0\u76fc\u84dd\u67d3\u8272\uff0c\u5c3d\u7ba1\u7ecf\u5178\u4f46\u8d39\u65f6\u8d39\u529b\uff0c\u4e14\u624b\u52a8\u8bef\u5dee\u5927\uff0c<\/p>\n","protected":false},"author":1852,"featured_media":997,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[8],"tags":[90],"division":[9],"class_list":["post-995","post","type-post","status-publish","format-standard","has-post-thumbnail","category-8","tag-90","division-bid","entry"],"_selected_authors":[1475],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2<\/title>\n<meta name=\"description\" content=\"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01\" \/>\n<meta property=\"og:description\" content=\"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-19T05:18:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T21:59:30+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"770\" \/>\n\t<meta property=\"og:image:height\" content=\"682\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Calvin Ye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Calvin Ye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/\"},\"author\":{\"name\":\"Calvin Ye\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"headline\":\"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01\",\"datePublished\":\"2026-03-19T05:18:31+00:00\",\"dateModified\":\"2026-04-22T21:59:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/\"},\"wordCount\":86,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260316-173628@2x.png\",\"keywords\":[\"\u6d41\u5f0f\"],\"articleSection\":[\"\u751f\u547d\u79d1\u5b66\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/\",\"name\":\"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260316-173628@2x.png\",\"datePublished\":\"2026-03-19T05:18:31+00:00\",\"dateModified\":\"2026-04-22T21:59:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\"},\"description\":\"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260316-173628@2x.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/wp-content\\\/uploads\\\/sites\\\/28\\\/2026\\\/03\\\/WX20260316-173628@2x.png\",\"width\":770,\"height\":682},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.cn\\\/blog\\\/accelerating-science-in-china\\\/cell-counting-methods\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/\",\"name\":\"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/accelerating-science-in-china\\\/#\\\/schema\\\/person\\\/da6699949979c67bbefa16fe029377fd\",\"name\":\"Calvin Ye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g\",\"caption\":\"Calvin Ye\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/calvin-yethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/","og_locale":"zh_CN","og_type":"article","og_title":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01","og_description":"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002","og_url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/","og_site_name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-03-19T05:18:31+00:00","article_modified_time":"2026-04-22T21:59:30+00:00","og_image":[{"width":770,"height":682,"url":"http:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png","type":"image\/png"}],"author":"Calvin Ye","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Calvin Ye","Est. reading time":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cell-counting-methods\/"},"author":{"name":"Calvin Ye","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"headline":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01","datePublished":"2026-03-19T05:18:31+00:00","dateModified":"2026-04-22T21:59:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cell-counting-methods\/"},"wordCount":86,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png","keywords":["\u6d41\u5f0f"],"articleSection":["\u751f\u547d\u79d1\u5b66"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/cell-counting-methods\/","url":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/","name":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01 - \u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png","datePublished":"2026-03-19T05:18:31+00:00","dateModified":"2026-04-22T21:59:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd"},"description":"\u4f20\u7edf\u624b\u52a8\u8ba1\u6570\u6cd5\u867d\u7ecf\u5178\u4f46\u5b58\u5728\u8017\u65f6\u8d39\u529b\u3001\u8bef\u5dee\u5927\u3001\u7ed3\u679c\u7a33\u5b9a\u6027\u5dee\u7b49\u95ee\u9898\uff0c\u81ea\u52a8\u5316\u7ec6\u80de\u8ba1\u6570\u4eea\u5219\u64cd\u4f5c\u7b80\u4fbf\u3001\u4f53\u79ef\u5c0f\u5de7\uff0c\u53ef\u63d0\u5347\u8ba1\u6570\u6548\u7387\u3002\u6d41\u5f0f\u7ec6\u80de\u8ba1\u6570\u6cd5\u5206\u4e24\u79cd\u5f62\u5f0f\uff0c\u80fd\u7cbe\u51c6\u63a7\u5236\u6837\u672c\u4f53\u79ef\u7684\u6d41\u5f0f\u7ec6\u80de\u4eea\u53ef\u76f4\u63a5\u5206\u6790\u6d53\u5ea6\uff0c\u5176\u4f59\u7684\u5219\u9700\u7ed3\u5408\u8ba1\u6570\u5fae\u7403\uff0c\u8fd8\u80fd\u5b9e\u73b0\u7ec6\u80de\u4e9a\u7fa4\u6d53\u5ea6\u6d4b\u5b9a\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png","width":770,"height":682},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.cn\/blog\/accelerating-science-in-china\/cell-counting-methods\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/"},{"@type":"ListItem","position":2,"name":"\u6d41\u5f0f\u8ba1\u6570\u9ed1\u79d1\u6280\uff0c\u5b9e\u9a8c\u6548\u7387\u5927\u5927\u63d0\u5347\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#website","url":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/","name":"\u8d5b\u9ed8\u98de\u4e2d\u6587\u535a\u5ba2","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/#\/schema\/person\/da6699949979c67bbefa16fe029377fd","name":"Calvin Ye","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bbe4236bccb5fcea6db0797643cf62d5613a642669442510a90ed606595e6a27?s=96&d=mm&r=g","caption":"Calvin Ye"},"url":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"\u751f\u547d\u79d1\u5b66"}],"post_tag":[{"value":90,"label":"\u6d41\u5f0f"}],"division":[{"value":9,"label":"BID"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/accelerating-science-in-china\/wp-content\/uploads\/sites\/28\/2026\/03\/WX20260316-173628@2x.png",760,673,false],"author_info":{"display_name":"Calvin Ye","author_link":"https:\/\/admin.acceleratingscience.com\/author\/calvin-yethermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"\u751f\u547d\u79d1\u5b66","slug":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","meta":[],"cat_ID":8,"category_count":136,"category_description":"","cat_name":"\u751f\u547d\u79d1\u5b66","category_nicename":"%e7%94%9f%e5%91%bd%e7%a7%91%e5%ad%a6","category_parent":0}],"tag_info":[{"term_id":90,"name":"\u6d41\u5f0f","slug":"%e6%b5%81%e5%bc%8f","term_group":0,"term_taxonomy_id":90,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/users\/1852"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/comments?post=995"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/posts\/995\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media\/997"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/media?parent=995"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/categories?post=995"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/tags?post=995"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/accelerating-science-in-china\/wp-json\/wp\/v2\/division?post=995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}