
{"id":1223,"date":"2019-01-07T00:00:00","date_gmt":"2019-01-07T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/"},"modified":"2026-02-17T22:10:44","modified_gmt":"2026-02-17T22:10:44","slug":"ar-ar-dating-to-determine-the-age-of-fossils","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/","title":{"rendered":"Ar-Ar Dating to Determine the Age of Fossils"},"content":{"rendered":"<div class=\"lia-message-body-content\"><span class=\"lia-inline-image-display-wrapper\"><img decoding=\"async\" class=\"lia-media-image alignleft\" title=\"argon\" role=\"button\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Ar-Ar-Dating-to-Determine-the-Age-of-Fossils-0.jpg\" alt=\"argon\" \/><\/span>Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.Noble gas mass spectrometry analyzes the isotopes of all five noble gases with low volume, beam de\ufb02ection multicollector array and 10<sup>13<\/sup> Ohm Ampli\ufb01er Technology. This array of technology o\ufb00ers unparalleled accuracy and precision. The lower the volume, the higher the sensitivity.<\/p>\n<h3 id=\"toc-hId--1902366818\"><strong>But, how does a noble gas mass spectrometer help us answer when the dinosaurs went extinct? <\/strong><\/h3>\n<p>Scientists use a method called Ar-Ar dating to determine the age of the fossils they discover. Back when dinosaurs roamed the planet, volcanoes were more active. Lava \ufb02owed and sediment blanketed the earth. Now and then dinosaurs died and asteroids would crash down from outer space, preserving the dinosaurs under even more layers of sediment.<\/p>\n<p>When paleontologists find these fossils, they are usually sandwiched between millions of years\u2019 worth of sediments, or volcanic material.<\/p>\n<p>When lava cools, it hardens and the trapped potassium decays very slowly to argon. Not only is this new argon trapped inside, but today, scientists can measure argon and its isotopes using systems like the <strong><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAEGACVFAKTMAWF\" target=\"_blank\" rel=\"nofollow noopener\">Thermo Scienti\ufb01c Argus VI noble gas mass spectrometer<\/a>.<\/strong><\/p>\n<p>In this way, argon is like a clock. A sample\u2019s isotope-ratio tell us precisely when a layer of sediment was formed. Performing Ar-Ar dating tests on various samples found near a fossil gives paleontologists a rough idea of when that specimen died.<\/p>\n<p>But argon isn\u2019t the only noble gas with a story to tell. There is so much to learn. Put the Thermo Scienti\ufb01c noble gas mass spectrometers to work, and solve the age-old riddle: How old is that rock?<\/p>\n<p>Whether you\u2019re working with boulders or 50 microns of stardust. The lower the volume, the higher the sensitivity.<\/p>\n<p>For more information on noble gas analysis, visit <a href=\"https:\/\/www.thermofisher.com\/NobleGasMS\" target=\"_blank\" rel=\"nofollow noopener\" data-wplink-edit=\"true\">www.thermofisher.com\/NobleGasMS<\/a><\/p>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=VdYRJyqlOWE\" target=\"test_blank\" rel=\"nofollow noopener noreferrer\">https:\/\/www.youtube.com\/watch?v=VdYRJyqlOWE<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon. Noble gas mass spectrometry analyzes<\/p>\n","protected":false},"author":1327,"featured_media":1225,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[666],"tags":[120],"division":[],"class_list":{"0":"post-1223","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-industrial","8":"tag-oil-gas","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ar-Ar Dating to Determine the Age of Fossils - AnalyteGuru<\/title>\n<meta name=\"description\" content=\"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ar-Ar Dating to Determine the Age of Fossils\" \/>\n<meta property=\"og:description\" content=\"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2019-01-07T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-17T22:10:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"999\" \/>\n\t<meta property=\"og:image:height\" content=\"561\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"headline\":\"Ar-Ar Dating to Determine the Age of Fossils\",\"datePublished\":\"2019-01-07T00:00:00+00:00\",\"dateModified\":\"2026-02-17T22:10:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/\"},\"wordCount\":326,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/3585-og.jpg\",\"keywords\":[\"Oil &amp; Gas\"],\"articleSection\":[\"Industrial\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/\",\"name\":\"Ar-Ar Dating to Determine the Age of Fossils - AnalyteGuru\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/3585-og.jpg\",\"datePublished\":\"2019-01-07T00:00:00+00:00\",\"dateModified\":\"2026-02-17T22:10:44+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"description\":\"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/3585-og.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/3585-og.jpg\",\"width\":999,\"height\":561},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/ar-ar-dating-to-determine-the-age-of-fossils\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ar-Ar Dating to Determine the Age of Fossils\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ar-Ar Dating to Determine the Age of Fossils - AnalyteGuru","description":"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/","og_locale":"en_US","og_type":"article","og_title":"Ar-Ar Dating to Determine the Age of Fossils","og_description":"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2019-01-07T00:00:00+00:00","article_modified_time":"2026-02-17T22:10:44+00:00","og_image":[{"width":999,"height":561,"url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"headline":"Ar-Ar Dating to Determine the Age of Fossils","datePublished":"2019-01-07T00:00:00+00:00","dateModified":"2026-02-17T22:10:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/"},"wordCount":326,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","keywords":["Oil &amp; Gas"],"articleSection":["Industrial"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/","name":"Ar-Ar Dating to Determine the Age of Fossils - AnalyteGuru","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","datePublished":"2019-01-07T00:00:00+00:00","dateModified":"2026-02-17T22:10:44+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"description":"Have you ever wondered how we can tell when the dinosaurs went extinct? The answers lie in the noble gas argon.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","width":999,"height":561},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/ar-ar-dating-to-determine-the-age-of-fossils\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Ar-Ar Dating to Determine the Age of Fossils"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":666,"label":"Industrial"}],"post_tag":[{"value":120,"label":"Oil &amp; Gas"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg",760,427,false],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":666,"name":"Industrial","slug":"industrial","term_group":0,"term_taxonomy_id":666,"taxonomy":"category","description":"","parent":0,"count":22,"filter":"raw","meta":[],"cat_ID":666,"category_count":22,"category_description":"","cat_name":"Industrial","category_nicename":"industrial","category_parent":0}],"tag_info":[{"term_id":120,"name":"Oil &amp; Gas","slug":"oil-gas","term_group":0,"term_taxonomy_id":120,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/3585-og.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/1223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=1223"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/1223\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/1225"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=1223"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=1223"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=1223"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=1223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}