{"id":14435,"date":"2023-05-09T08:00:00","date_gmt":"2023-05-09T08:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/?p=14435"},"modified":"2026-06-23T21:18:38","modified_gmt":"2026-06-23T21:18:38","slug":"lithium-ion-battery-production-the-analytical-techniques-used","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/","title":{"rendered":"Lithium-Ion Battery Production: The Analytical Techniques Used"},"content":{"rendered":"\n<p>The surge in demand for high-performance batteries is driving significant investment in every stage of production. Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process, all the way from raw material production to recycling spent batteries. &nbsp;To meet the analysis requirements, a wide range of instruments, software and related technologies is required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"toc-hId-1155122479\"><strong>Analytical techniques across the battery supply chain<\/strong><\/h3>\n\n\n\n<p><strong>Research<br><\/strong>This work involves development of next-generation battery materials and improvements in existing lithium battery technologies.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"516\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/05\/Lithium-ion-battery-material-analysis-4.jpg\" alt=\"Lithium-ion battery\" class=\"wp-image-14447\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/05\/Lithium-ion-battery-material-analysis-4.jpg 1000w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/05\/Lithium-ion-battery-material-analysis-4-300x155.jpg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/05\/Lithium-ion-battery-material-analysis-4-768x396.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Processes include<\/strong><\/td><td><strong>Analytical need<\/strong><\/td><td><strong>Analytical techniques<\/strong><\/td><\/tr><tr><td>Novel cathode active materials researchElectrolyte, cathode and anode material degradation product studiesExploration of new methods and improvement of existing techniques for battery material recyclingDevelopment of next-generation batteries (e.g., solid state, sodium)&nbsp;<\/td><td>Material composition and purity characterizationFailure analysis&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<strong>&nbsp;<\/strong><\/td><td>ICP-OESICP-MSIC\/IC-MSLC\/LC-MSGC-GC-MSHR-ICP-MSGD-MSOEA<strong>&nbsp;<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Raw materials<br><\/strong>This step of the supply chain involves mining, processing and refining raw materials, such as lithium, manganese, nickel, cobalt and iron salts, graphite and silicon.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Processes include<\/strong><\/td><td><strong>Analytical need<\/strong><\/td><td><strong>Analytical techniques<\/strong><\/td><\/tr><tr><td>Mined material processingRefined product purity analysisQuality assurance and control&nbsp;&nbsp;<\/td><td>Bulk process control and quality control (QC)Mineral, ore and brine analysis for lithium and impurity element analysisConfirmation of material quality&nbsp;<\/td><td>ICP-OESICP-MSIC\/IC-MSOEA<strong>&nbsp;<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Cell components and assembly<br><\/strong>In this stage, a variety of processes, including development of novel chemistries, anodes, cathodes, electrolytes and separators, as well as on-line inspection are required. This step also covers mixing of materials, coating, drying, calendering and stacking of battery jelly rolls, and packaging components into pouch, prismatic or cylindrical forms.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Processes include<\/strong><\/td><td><strong>Analytical need<\/strong><\/td><td><strong>Analytical techniques<\/strong><\/td><\/tr><tr><td>Manufacturing of battery cells and\/or cell arraysElectrolyte composition confirmation&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/td><td>Ensure quality of designProcess controlIn-line inspectionFailure analysis and material rejectionComposition measurementDetection and quantification of elemental impuritiesDegradation studiesResearch and routine QA\/QC measurement<\/td><td>ICP-OESICP-MSGC\/GC-MSIC\/IC-MS&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Battery testing<br><\/strong>During this phase, manufacturers need to ensure that the finished battery cells meet specification before they are assembled into battery packs.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Processes include<\/strong><\/td><td><strong>Analytical need<\/strong><\/td><td><strong>Analytical techniques<\/strong><\/td><\/tr><tr><td>Failure analysis and rejectionBattery aging, environmental and electrical studies&nbsp;&nbsp;<\/td><td>Analysis of degradation products:Cathode material compoundsElectrolytesSeparator degradation products<\/td><td>ICP-OESICP-MSLC\/LC-MSGC\/GC-MSIC\/IC-MS<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Battery recycling<br><\/strong>This final stage of the battery supply chain incorporates bulk recycling and recovery of cathode and anode materials (the so-called \u2018black mass\u2019) and includes recycling of both end-of-life batteries and manufacturing scrap from failed cells to retrieve and refine the material for use in new batteries.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Processes include<\/strong><\/td><td><strong>Analytical need<\/strong><\/td><td><strong>Analytical techniques<\/strong><\/td><\/tr><tr><td>Material recoveryInspection and reuseBattery recyclingTesting&nbsp;&nbsp;<\/td><td>InspectionCharacterization&nbsp;&nbsp;&nbsp;&nbsp;<\/td><td>ICP-OESICP-MSHPLCIC\/IC-MSLC\/LC-MSGC\/GC-MS<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"toc-hId-2042626160\">&nbsp;<strong>What are the analytical techniques?<\/strong><\/h3>\n\n\n\n<p><strong>ICP-OES<\/strong>&nbsp;\u2013 Inductively coupled plasma optical emission spectrometry<\/p>\n\n\n\n<p><strong>ICP-MS<\/strong>&nbsp;\u2013 Inductively coupled plasma mass spectrometry<\/p>\n\n\n\n<p><strong>HPLC<\/strong>&nbsp;\u2013 High performance liquid chromatography<\/p>\n\n\n\n<p><strong>LC-MS<\/strong>&nbsp;\u2013 Liquid chromatography mass spectrometry<\/p>\n\n\n\n<p><strong>IC<\/strong>&nbsp;\u2013 Ion chromatography<\/p>\n\n\n\n<p><strong>GC<\/strong>&nbsp;\u2013 Gas chromatography<\/p>\n\n\n\n<p><strong>GC-MS<\/strong>&nbsp;\u2013 Gas chromatography mass spectrometry<\/p>\n\n\n\n<p><strong>IC-MS<\/strong>&nbsp;\u2013 Ion chromatography mass spectrometry<\/p>\n\n\n\n<p><strong>HR-ICP-MS<\/strong>&nbsp;\u2013 High resolution inductively coupled plasma mass spectrometry<\/p>\n\n\n\n<p><strong>GD-MS<\/strong>&nbsp;\u2013 Glow discharge mass spectrometry<\/p>\n\n\n\n<p><strong>OEA<\/strong>&nbsp;\u2013 Organic elemental analyzer<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"toc-hId--477333774\"><strong>Why these analytical techniques?<\/strong><\/h3>\n\n\n\n<p><strong>Ion chromatography<\/strong>&nbsp;\u2013 By using ion chromatography, researchers and scientists can confirm the anionic composition and purity of electrolyte solutions and gain insights into degradation mechanisms in lithium-ion batteries to ensure product quality during manufacturing.<\/p>\n\n\n\n<p><strong>Gas chromatography<\/strong>&nbsp;\u2013 Gas chromatography-mass spectrometry (GC-MS) systems can reach lower detection limits and obtain richer information with sensitive detection and accurate mass-fragment and molecular ion identification. By identifying and quantifying compounds formed during electrolyte aging, GC-MS systems can provide new insight into Li-ion battery degradation.<\/p>\n\n\n\n<p><strong>Mass spectrometry<\/strong>&nbsp;\u2013 When studying lithium-ion battery components, detection using mass spectrometry (MS) dramatically extends the capabilities of ion and liquid chromatography (IC and HPLC) systems and provides higher sensitivity, accurate quantitation, peak confirmation and evaluation of chromatography peak purity, improved resolution of complex samples with seamless integration of MS data into IC and HPLC workflows.<\/p>\n\n\n\n<p><strong>Elemental analysis<\/strong>&nbsp;\u2013 Long before lithium-ion batteries are produced, laboratories use elemental analysis to determine the composition and purity of lithium-rich brine and lithium ores which will eventually be refined into battery component materials. The refined materials also require elemental analysis to ensure their composition and purity before use, since the presence of impurities significantly degrades the performance and lifetime of the battery.<\/p>\n\n\n\n<p><strong>Liquid chromatography<\/strong>&nbsp;\u2013 Whether you\u2019re analyzing electrolyte solvents or working to achieve the next breakthrough in battery recycling, liquid chromatography solutions can improve your productivity, deliver a maximum return on your investment, and when coupled with mass spectrometry provide confident insights to drive business decisions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"toc-hId-410169907\"><strong>Additional Information<\/strong><\/h3>\n\n\n\n<p>To learn more about battery research and manufacturing, visit our\u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/battery-manufacturing.html\" target=\"_blank\" rel=\"noreferrer noopener\">website<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The surge in demand for high-performance batteries is driving significant investment in every stage of production. Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process, all the way from raw material production to recycling spent batteries. &nbsp;To meet the analysis requirements, a wide range of instruments, software<\/p>\n","protected":false},"author":1327,"featured_media":14436,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[90],"tags":[33,47],"division":[],"class_list":{"0":"post-14435","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-battery-material-analysis","8":"tag-gc-ms","9":"tag-icp-oes","10":"entry"},"_selected_authors":[1766],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Lithium-Ion Battery Production: The Analytical Techniques Used - AnalyteGuru<\/title>\n<meta name=\"description\" content=\"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lithium-Ion Battery Production: The Analytical Techniques Used\" \/>\n<meta property=\"og:description\" content=\"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-09T08:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-23T21:18:38+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"516\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"headline\":\"Lithium-Ion Battery Production: The Analytical Techniques Used\",\"datePublished\":\"2023-05-09T08:00:00+00:00\",\"dateModified\":\"2026-06-23T21:18:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/\"},\"wordCount\":783,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/Lithium-ion-battery-material-analysis-4.jpg\",\"keywords\":[\"GC-MS\",\"ICP-OES\"],\"articleSection\":[\"Battery Material Analysis\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/\",\"name\":\"Lithium-Ion Battery Production: The Analytical Techniques Used - AnalyteGuru\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/Lithium-ion-battery-material-analysis-4.jpg\",\"datePublished\":\"2023-05-09T08:00:00+00:00\",\"dateModified\":\"2026-06-23T21:18:38+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"description\":\"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/Lithium-ion-battery-material-analysis-4.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/Lithium-ion-battery-material-analysis-4.jpg\",\"width\":1000,\"height\":516,\"caption\":\"Lithium-ion battery\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/lithium-ion-battery-production-the-analytical-techniques-used\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lithium-Ion Battery Production: The Analytical Techniques Used\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Lithium-Ion Battery Production: The Analytical Techniques Used - AnalyteGuru","description":"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/","og_locale":"en_US","og_type":"article","og_title":"Lithium-Ion Battery Production: The Analytical Techniques Used","og_description":"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2023-05-09T08:00:00+00:00","article_modified_time":"2026-06-23T21:18:38+00:00","og_image":[{"width":1000,"height":516,"url":"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"headline":"Lithium-Ion Battery Production: The Analytical Techniques Used","datePublished":"2023-05-09T08:00:00+00:00","dateModified":"2026-06-23T21:18:38+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/"},"wordCount":783,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","keywords":["GC-MS","ICP-OES"],"articleSection":["Battery Material Analysis"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/","name":"Lithium-Ion Battery Production: The Analytical Techniques Used - AnalyteGuru","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","datePublished":"2023-05-09T08:00:00+00:00","dateModified":"2026-06-23T21:18:38+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"description":"Laboratories associated with battery research and manufacturing need material analysis solutions in each step of the process.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","width":1000,"height":516,"caption":"Lithium-ion battery"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/lithium-ion-battery-production-the-analytical-techniques-used\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Lithium-Ion Battery Production: The Analytical Techniques Used"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":90,"label":"Battery Material Analysis"}],"post_tag":[{"value":33,"label":"GC-MS"},{"value":47,"label":"ICP-OES"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg",760,392,false],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":90,"name":"Battery Material Analysis","slug":"battery-material-analysis","term_group":0,"term_taxonomy_id":90,"taxonomy":"category","description":"","parent":0,"count":13,"filter":"raw","meta":[],"cat_ID":90,"category_count":13,"category_description":"","cat_name":"Battery Material Analysis","category_nicename":"battery-material-analysis","category_parent":0}],"tag_info":[{"term_id":33,"name":"GC-MS","slug":"gc-ms","term_group":0,"term_taxonomy_id":33,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw","meta":[]},{"term_id":47,"name":"ICP-OES","slug":"icp-oes","term_group":0,"term_taxonomy_id":47,"taxonomy":"post_tag","description":"","parent":0,"count":14,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Lithium-ion-battery-material-analysis-4.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/14435","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=14435"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/14435\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/14436"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=14435"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=14435"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=14435"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=14435"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}