
{"id":15901,"date":"2023-10-13T19:06:42","date_gmt":"2023-10-13T19:06:42","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/?p=15901"},"modified":"2023-10-28T00:23:49","modified_gmt":"2023-10-28T00:23:49","slug":"multiply-substituted-isotopologues","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/","title":{"rendered":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues"},"content":{"rendered":"\n<p><em>This is the second in a series on Isotope analysis using Orbitrap technology.<\/em><\/p>\n\n\n\n<p>Multiply substituted isotopologues? It may sound complicated, but it\u2019s remarkably simple and extremely useful. And even better, it\u2019s easy to measure with the Thermo Scientific Orbitrap Exploris Isotope Solutions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-what-is-a-multiply-substituted-isotopologue\"><strong>What is a multiply substituted isotopologue?<\/strong><\/h3>\n\n\n\n<p>Take a molecule, e.g., CO<sub>2<\/sub>. The most common variety of CO<sub>2<\/sub> is <sup>12<\/sup>C<sup>16<\/sup>O<sup>16<\/sup>O. But in rare cases, the <sup>12<\/sup>C could be replaced by a <sup>13<\/sup>C and the <sup>16<\/sup>O could be replaced by <sup>17<\/sup>O or <sup>18<\/sup>O. Where two or more of these isotopes have been swapped, this is called a multiply substituted isotopologue.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-why-do-we-care-about-multiply-substituted-isotopologues\"><strong>Why do we care about<\/strong> <strong>multiply substituted isotopologues?<\/strong><\/h3>\n\n\n\n<p>Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule. For example, the carbonate multiple substituted isotopologue (<sup>13<\/sup>C<sup>18<\/sup>O<sup>16<\/sup>O, aka \u039447) has been widely used as a paleo-thermometer that is independent of variations in the oxygen isotopic composition of the source water. Similarly, multiply substituted isotopologues of methane have been used to identify the process of methane production in carbon capture and storage sites (e.g., <a href=\"https:\/\/www.nature.com\/articles\/s41586-021-04153-3\" target=\"_blank\" rel=\"noreferrer noopener\">Tyne et al. 2021<\/a>). &nbsp;Multiply substituted isotopologues can provide important insights in biochemical applications, using isotope labeling to decipher metabolic pathways.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"614\" src=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-2-Final-1024x614.jpg\" alt=\"\" class=\"wp-image-15904\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-2-Final-1024x614.jpg 1024w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-2-Final-300x180.jpg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-2-Final-768x461.jpg 768w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-2-Final.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-why-are-multiply-substituted-isotopologues-traditionally-tricky-to-analyze\"><strong>Why are multiply substituted isotopologues traditionally tricky to analyze?<\/strong><\/h3>\n\n\n\n<p>Because of the difference in abundance between multiply substituted isotopologues and the major species, multiply substituted isotopologues have traditionally been tricky to measure. They require instrumentation that is sensitive enough to detect the minor isotope beams and also has the resolution to detect isobaric species, e.g., <sup>13<\/sup>C<sup>18<\/sup>O<sup>16<\/sup>O from <sup>12<\/sup>C<sup>18<\/sup>O<sup>17<\/sup>O.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-what-is-game-changing-about-the-orbitrap-exploris-isotope-solutions\"><strong>What is game changing about the Orbitrap Exploris Isotope Solutions?<\/strong><\/h3>\n\n\n\n<p>The Orbitrap Exploris Isotope Solutions has a mass resolution of up to 480,000 (at 200 <em>m<\/em>\/<em>z<\/em>), allowing separation of isotopologues that are far beyond the reach of even the highest resolution magnetic sector mass spectrometer. &nbsp;What\u2019s more, because it is possible to limit the mass range entering the analyzer, the major species can be excluded (so-called \u201cnoM0\u201d methodology), allowing a greater number of counts on the multiply substituted isotopologues. This means that the sensitivity of Orbitrap Exploris Isotope Solutions is adaptable for your application and the multiply substituted isotopologues of interest.<\/p>\n\n\n\n<p>For more information, visit: <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAMGAATFARBMBNP\" target=\"_blank\" rel=\"noreferrer noopener\">thermofisher.com\/orbitrap-for-isotopes<\/a>.<\/p>\n\n\n\n<p>Bulk isotopic composition of multiply substituted isotopologues is just the tip of the iceberg in terms of the advantage of the Orbitrap Exploris Isotope Solutions. Read Part 3 of this series to find out about how this technology can be used to uncover site-specific isotope information.<\/p>\n\n\n\n<p><strong>Related blog posts in this three-part series<\/strong><\/p>\n\n\n\n<p>Part 1: <a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/boost-your-productivity-with-the-isotopic-analysis-of-intact-molecules\/\" target=\"_blank\" rel=\"noreferrer noopener\">Boost Your Productivity with the Isotopic Analysis of Intact Molecules<\/a><\/p>\n\n\n\n<p>Part 3: <a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/new-dimensions-in-isotope-ratio-analysis-site-specificity\/\" target=\"_blank\" rel=\"noreferrer noopener\">New Dimensions in Isotope Ratio Analysis: Site Specificity<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is the second in a series on Isotope analysis using Orbitrap technology. Multiply substituted isotopologues? It may sound complicated, but it\u2019s remarkably simple and extremely useful. And even better, it\u2019s easy to measure with the Thermo Scientific Orbitrap Exploris Isotope Solutions. What is a multiply substituted isotopologue? Take a molecule, e.g., CO2. The most<\/p>\n","protected":false},"author":1327,"featured_media":15909,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[459,92],"tags":[462,24],"division":[],"class_list":{"0":"post-15901","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-isotope-ratio-ms","8":"category-metabolomics","9":"tag-isotope-ratio-ms","10":"tag-orbitrap","11":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues - AnalyteGuru<\/title>\n<meta name=\"description\" content=\"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues\" \/>\n<meta property=\"og:description\" content=\"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-13T19:06:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-28T00:23:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"623\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"headline\":\"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues\",\"datePublished\":\"2023-10-13T19:06:42+00:00\",\"dateModified\":\"2023-10-28T00:23:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/\"},\"wordCount\":458,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/10\\\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg\",\"keywords\":[\"Isotope Ratio MS\",\"Orbitrap\"],\"articleSection\":[\"Isotope Ratio MS\",\"Metabolomics\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/\",\"name\":\"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues - AnalyteGuru\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/10\\\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg\",\"datePublished\":\"2023-10-13T19:06:42+00:00\",\"dateModified\":\"2023-10-28T00:23:49+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"description\":\"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/10\\\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/10\\\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg\",\"width\":1200,\"height\":623,\"caption\":\"Isotope Ratio Analysis - Orbitrap\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multiply-substituted-isotopologues\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues - AnalyteGuru","description":"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/","og_locale":"en_US","og_type":"article","og_title":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues","og_description":"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2023-10-13T19:06:42+00:00","article_modified_time":"2023-10-28T00:23:49+00:00","og_image":[{"width":1200,"height":623,"url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"headline":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues","datePublished":"2023-10-13T19:06:42+00:00","dateModified":"2023-10-28T00:23:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/"},"wordCount":458,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","keywords":["Isotope Ratio MS","Orbitrap"],"articleSection":["Isotope Ratio MS","Metabolomics"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/","name":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues - AnalyteGuru","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","datePublished":"2023-10-13T19:06:42+00:00","dateModified":"2023-10-28T00:23:49+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"description":"Multiply substituted isotopologues give us important insights into the conditions and processes forming that molecule.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","width":1200,"height":623,"caption":"Isotope Ratio Analysis - Orbitrap"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multiply-substituted-isotopologues\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"New Dimensions in Isotope Ratio Analysis: Multiply Substituted Isotopologues"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":459,"label":"Isotope Ratio MS"},{"value":92,"label":"Metabolomics"}],"post_tag":[{"value":462,"label":"Isotope Ratio MS"},{"value":24,"label":"Orbitrap"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final-1024x532.jpg",760,395,true],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":459,"name":"Isotope Ratio MS","slug":"isotope-ratio-ms","term_group":0,"term_taxonomy_id":459,"taxonomy":"category","description":"","parent":0,"count":18,"filter":"raw","meta":[],"cat_ID":459,"category_count":18,"category_description":"","cat_name":"Isotope Ratio MS","category_nicename":"isotope-ratio-ms","category_parent":0},{"term_id":92,"name":"Metabolomics","slug":"metabolomics","term_group":0,"term_taxonomy_id":92,"taxonomy":"category","description":"","parent":0,"count":18,"filter":"raw","meta":[],"cat_ID":92,"category_count":18,"category_description":"","cat_name":"Metabolomics","category_nicename":"metabolomics","category_parent":0}],"tag_info":[{"term_id":462,"name":"Isotope Ratio MS","slug":"isotope-ratio-ms","term_group":0,"term_taxonomy_id":462,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":24,"name":"Orbitrap","slug":"orbitrap","term_group":0,"term_taxonomy_id":24,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/10\/HubbleBrochureCover-TR-orby-swirl-blog-3-Final.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/15901","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=15901"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/15901\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/15909"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=15901"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=15901"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=15901"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=15901"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}