
{"id":19198,"date":"2025-10-07T08:56:14","date_gmt":"2025-10-07T08:56:14","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/?p=19198"},"modified":"2026-04-27T15:43:06","modified_gmt":"2026-04-27T15:43:06","slug":"how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/","title":{"rendered":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\" id=\"h-struggling-to-accurately-measure-semi-volatile-analytes-stricter-temperature-control-with-hplc-cad-analysis-just-might-be-the-solution-you-need\">Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover-1024x512.jpeg\" alt=\"Temperature regulation graphic image\" class=\"wp-image-19200\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover-1024x512.jpeg 1024w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover-300x150.jpeg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover-768x384.jpeg 768w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>The charged aerosol detector (CAD) is cited as one of the most capable near-universal HPLC detectors available because the response is solely based on particle charge and fully independent of chemical structure.<\/p>\n\n\n\n<p>One caveat to know is your mobile phase components must be less volatile than the analytes in solution for detection by the CAD. And while all non-volatiles give a similar uniform response, <a href=\"\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection\/charged-aerosol-detection-cad-performance-tips.html\">the response of semi-volatiles<\/a> depends on volatility and consequently is less predictable.<\/p>\n\n\n\n<p>So, the question then becomes is there a way to address this performance difference and make semi-volatile detection more predictable? One approach for charged semi-volatile analytes is to add a volatile ion-pairing agent of the opposite charge in the mobile phase to force non-volatile behavior.<\/p>\n\n\n\n<p>However, this method is analyte specific and may also react with impurities in your mobile phase, leading to higher noise and poorer signal-to-noise (S\/N) ratio. &nbsp;What\u2019s really needed is a more global approach to improve the accuracy for measuring semi-volatiles.<\/p>\n\n\n\n<p>This approach is now achievable with Temperature Coupling Mode (TCM) in the <a href=\"https:\/\/discover-pharma.com\/thermo-fisher-upgrades-charged-aerosol-detection-tech-to-improve-complex-drug-analysis\/\" target=\"_blank\" rel=\"noreferrer noopener\">Thermo Scientific Vanquish CAD P Series<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-why-stricter-temperature-control-matters-for-measuring-semi-volatiles\"><strong>Why stricter temperature control matters for measuring semi-volatiles<\/strong><\/h3>\n\n\n\n<p>Before we get into the specifics, you need to understand why temperature control in the CAD is critical to quantitative accuracy, especially for semi-volatiles (<strong>Figure 1<\/strong>).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/How-CAD-works-illustration-1024x512.jpeg\" alt=\"Illustration showing how the CAD works\" class=\"wp-image-19203\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/How-CAD-works-illustration-1024x512.jpeg 1024w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/How-CAD-works-illustration-300x150.jpeg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/How-CAD-works-illustration-768x384.jpeg 768w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/How-CAD-works-illustration.jpeg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center has-small-font-size\"><strong>Figure 1<\/strong>. Illustration showing how the CAD works.<\/p>\n\n\n\n<p>The two <a href=\"\/content\/lifetech\/global\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/liquid-chromatography-information\/hplc-system-components\/how-hplc-detectors-work\/charged-aerosol-detection.html\">most important functional components in the CAD that guide sensitivity<\/a> are the evaporation tube temperature (<strong>EvapT<\/strong>) and the charging detection module (<strong>CDM<\/strong>).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>EvapT plays a crucial role in determining the performance of the detector, and changing this temperature may alter analyte \u201cselectivity\u201d<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The CDM is where particle charge and measurement happen<\/li>\n<\/ul>\n\n\n\n<p>In previous CAD models, the EvapT is adjustable, but the temperature of the CDM is permanently set at 40 \u00b0C. This fixed temperature difference between the EvapT and CDM could negatively impact the measurement of semi-volatile compounds that require a lower EvapT.<\/p>\n\n\n\n<p>Adding TCM resolves this issue, by linking the EvapT and CDM temperatures, thereby improving the quantitation of semi-volatile species.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-using-tcm-to-help-improve-quantification-of-semi-volatiles-like-fatty-acids\"><strong>Using TCM to help improve quantification of semi-volatiles, like fatty acids<\/strong><\/h3>\n\n\n\n<p>To demonstrate the effectiveness of this new temperature coupling feature, we anlazyed a working solution of four individual fatty acids (FAs) and compared the CAD repsonse with TCM turned on and turned off (<strong>Figure 2<\/strong>).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"410\" src=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Fatty-acid-analysis-with-temperature-coupling-mode-1.jpeg\" alt=\"The mean S\/N ratio of the FAs analyzed with TCM turned on and off\" class=\"wp-image-19205\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Fatty-acid-analysis-with-temperature-coupling-mode-1.jpeg 700w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Fatty-acid-analysis-with-temperature-coupling-mode-1-300x176.jpeg 300w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center has-small-font-size\"><strong>Figure 2<\/strong>. The mean S\/N ratio of the FAs analyzed with TCM turned on and off.<\/p>\n\n\n\n<p>Notably, we observed 46.8% increase in the S\/N at the optimal EvapT of 25 \u00b0C and with the TCM switched on for lauric acid, the most semi-volatile compound!<\/p>\n\n\n\n<p>Interestingly, the observed S\/N improvement matches the respective analyte volatility\u2014lauric acid (lowest MW) shows the greatest improvement, and stearic acid (highest MW) the least.<\/p>\n\n\n\n<p>Taken together, these findings show how stricter temperature control in the CAD can allow you to extend the range and improve quantification of semi-volatiles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-extending-this-application-to-impurity-analysis-of-polysorbates\"><strong>Extending this application to impurity analysis of polysorbates<\/strong><\/h3>\n\n\n\n<p>Now that we\u2019ve seen TCM is useful for analyzing fatty acids, let\u2019s consider more complex solutions, like polysorbates.<\/p>\n\n\n\n<p>Given the CAD is well-established for determining <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0021967324010240?via%3Dihub\" target=\"_blank\" rel=\"noreferrer noopener\">polysorbate impurities<\/a>, and fatty acid impurities are quite abundant in polysorbates, and a logical next step is to use this technique for analyzing these solutions.<\/p>\n\n\n\n<p>Afterall, free acids in polysorbates <a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/review-of-analytical-methods-for-quantifying-amp-profiling\/\">may form insoluble particles<\/a> that can seriously compromise product quality, efficacy, and patient safety. Thus, your ability to accurately measure these acids in raw materials and finished goods is of the upmost importance.<\/p>\n\n\n\n<p>Download our paper to see how the <a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-003867-hplc-vanquish-cad-gradient-optimized-evap-temp-an003867-na-en.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Vanquish CAD P Series<\/a> can help your lab measure fatty acids with greater confidence today.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"410\" src=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Vanquish-CAD-P-Series.jpeg\" alt=\"Thermo Scientific Vanquish CAD P Series \" class=\"wp-image-19207\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Vanquish-CAD-P-Series.jpeg 700w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/Vanquish-CAD-P-Series-300x176.jpeg 300w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center has-small-font-size\"><strong>Figure 3<\/strong>. Thermo Scientific Vanquish CAD P Series<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-faqs\"><strong>FAQs<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>What are the advantages of using a charged aerosol detector for HPLC analysis?<\/strong><\/li>\n<\/ol>\n\n\n\n<p>The <a href=\"\/content\/lifetech\/global\/en\/home\/c\/b\/vanquish-charged-aerosol-detector-p-series.html\">charged aerosol detector<\/a> (CAD) is now recognized as the most capable \u201cuniversal\u201d detector available and offers several advantages over other UHPLC-based detectors including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Uniform response for all non-volatile analytes (ideal for quantitation when certified standards are unavailable)<\/li>\n\n\n\n<li>Universal response independent of chemical structure (analyte does not have to form gas phase ions or possess a chromophore)<\/li>\n\n\n\n<li>High sensitivity at high pg to low ng on column (ideal for drug impurity analysis)<\/li>\n\n\n\n<li>Wide linear and dynamic range (measure API and impurities in one run)<\/li>\n\n\n\n<li>Simple calibration curves (no need to deal with complex, unpredictable sigmoidal calibration curves)<\/li>\n\n\n\n<li>Gradient compatible (inverse gradient available to ensure consistent response throughout the gradient)<\/li>\n<\/ul>\n\n\n\n<p>    2. <strong>Why should I use CAD for measuring fatty acid impurities in polysorbates?<\/strong><\/p>\n\n\n\n<p>Fatty acids don\u2019t contain strong chromophores, so HPLC-CAD analysis is the <a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/cad-vs-elsd-which-hplc-detector-is-your-better-option\/\">ideal choice<\/a> since the detector response depends on particle charge and is independent of analyte structure.<\/p>\n\n\n\n<p>     3. <strong>How does changing the evaporation tube temperature affect the CAD response for semi-volatiles?<\/strong><\/p>\n\n\n\n<p>A high EvapT can <a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CMD\/Technical-Notes\/tn-72806-uhplc-charged-aerosol-detection-tn72806-en.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">improve sensitivity<\/a> for non-volatiles by reducing noise but may negatively impact measurement of semi-volatile species. Conversely, a lower EvapT can improve the detection of semi-volatile species, but sensitivity for all analytes may be adversely impacted due to increased noise.<\/p>\n\n\n\n<p>Visit us on\u00a0<a href=\"https:\/\/www.linkedin.com\/showcase\/72003132\/admin\/dashboard\/\" target=\"_blank\" rel=\"noreferrer noopener\"><u>LinkedIn:<\/u><\/a>\u00a0#HPLC #CAD #biopharma<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need. The charged aerosol detector (CAD) is cited as one of the most capable near-universal HPLC detectors available because the response is solely based on particle charge and fully independent of chemical structure. One caveat to know<\/p>\n","protected":false},"author":1760,"featured_media":19200,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[9],"tags":[41,1802,14,807],"division":[],"class_list":{"0":"post-19198","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-charged-aerosol-detection","8":"tag-biopharmaceutical","9":"tag-impurity-analysis","10":"tag-liquid-chromatography","11":"tag-quality-control","12":"entry"},"_selected_authors":[1546],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Get More Accurate HPLC Quantitation of Semi-Volatiles - AnalyteGuru<\/title>\n<meta name=\"description\" content=\"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Get More Accurate HPLC Quantitation of Semi-Volatiles\" \/>\n<meta property=\"og:description\" content=\"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-07T08:56:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-27T15:43:06+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kishore Sridhara\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kishore Sridhara\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/\"},\"author\":{\"name\":\"Kishore Sridhara\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/9e34def7f0dcc62e346995839a7bc832\"},\"headline\":\"How to Get More Accurate HPLC Quantitation of Semi-Volatiles\",\"datePublished\":\"2025-10-07T08:56:14+00:00\",\"dateModified\":\"2026-04-27T15:43:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/\"},\"wordCount\":854,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2025\\\/09\\\/TCM-blog-cover.jpeg\",\"keywords\":[\"Biopharmaceutical\",\"Impurity Analysis\",\"Liquid Chromatography\",\"Quality Control\"],\"articleSection\":[\"Charged Aerosol Detection\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/\",\"name\":\"How to Get More Accurate HPLC Quantitation of Semi-Volatiles - AnalyteGuru\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2025\\\/09\\\/TCM-blog-cover.jpeg\",\"datePublished\":\"2025-10-07T08:56:14+00:00\",\"dateModified\":\"2026-04-27T15:43:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/9e34def7f0dcc62e346995839a7bc832\"},\"description\":\"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2025\\\/09\\\/TCM-blog-cover.jpeg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2025\\\/09\\\/TCM-blog-cover.jpeg\",\"width\":1200,\"height\":600,\"caption\":\"Temperature regulation graphic image\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Get More Accurate HPLC Quantitation of Semi-Volatiles\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/9e34def7f0dcc62e346995839a7bc832\",\"name\":\"Kishore Sridhara\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"caption\":\"Kishore Sridhara\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kishoresridhara\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles - AnalyteGuru","description":"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/","og_locale":"en_US","og_type":"article","og_title":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles","og_description":"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2025-10-07T08:56:14+00:00","article_modified_time":"2026-04-27T15:43:06+00:00","og_image":[{"width":1200,"height":600,"url":"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","type":"image\/jpeg"}],"author":"Kishore Sridhara","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"Kishore Sridhara","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/"},"author":{"name":"Kishore Sridhara","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/9e34def7f0dcc62e346995839a7bc832"},"headline":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles","datePublished":"2025-10-07T08:56:14+00:00","dateModified":"2026-04-27T15:43:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/"},"wordCount":854,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","keywords":["Biopharmaceutical","Impurity Analysis","Liquid Chromatography","Quality Control"],"articleSection":["Charged Aerosol Detection"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/","name":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles - AnalyteGuru","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","datePublished":"2025-10-07T08:56:14+00:00","dateModified":"2026-04-27T15:43:06+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/9e34def7f0dcc62e346995839a7bc832"},"description":"Struggling to accurately measure semi-volatile analytes? Stricter temperature control with HPLC-CAD analysis just might be the solution you need.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","width":1200,"height":600,"caption":"Temperature regulation graphic image"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/how-to-get-more-accurate-hplc-quantitation-of-semi-volatiles\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"How to Get More Accurate HPLC Quantitation of Semi-Volatiles"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/9e34def7f0dcc62e346995839a7bc832","name":"Kishore Sridhara","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","caption":"Kishore Sridhara"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kishoresridhara\/"}]}},"taxonomy_info":{"category":[{"value":9,"label":"Charged Aerosol Detection"}],"post_tag":[{"value":41,"label":"Biopharmaceutical"},{"value":1802,"label":"Impurity Analysis"},{"value":14,"label":"Liquid Chromatography"},{"value":807,"label":"Quality Control"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover-1024x512.jpeg",760,380,true],"author_info":{"display_name":"Kishore Sridhara","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kishoresridhara\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Charged Aerosol Detection","slug":"charged-aerosol-detection","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":18,"filter":"raw","meta":[],"cat_ID":9,"category_count":18,"category_description":"","cat_name":"Charged Aerosol Detection","category_nicename":"charged-aerosol-detection","category_parent":0}],"tag_info":[{"term_id":41,"name":"Biopharmaceutical","slug":"biopharmaceutical","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":57,"filter":"raw","meta":[]},{"term_id":1802,"name":"Impurity Analysis","slug":"impurity-analysis","term_group":0,"term_taxonomy_id":1802,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":14,"name":"Liquid Chromatography","slug":"liquid-chromatography","term_group":0,"term_taxonomy_id":14,"taxonomy":"post_tag","description":"","parent":0,"count":79,"filter":"raw","meta":[]},{"term_id":807,"name":"Quality Control","slug":"quality-control","term_group":0,"term_taxonomy_id":807,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2025\/09\/TCM-blog-cover.jpeg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/19198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1760"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=19198"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/19198\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/19200"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=19198"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=19198"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=19198"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=19198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}