{"id":21220,"date":"2026-10-08T08:09:23","date_gmt":"2026-10-08T08:09:23","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/?p=21220"},"modified":"2026-10-08T08:09:25","modified_gmt":"2026-10-08T08:09:25","slug":"stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/","title":{"rendered":"Stellar MS Raises the Standard for DBS Steroid Ester Detection"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Dried blood spot analysis has promised anti-doping laboratories a faster, simpler, and less invasive way to detect steroid ester use. The problem has never been the promise. It has been the analytical reality.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image-1024x512.png\" alt=\"Close-up of runners racing on a track, emphasizing speed and high performance.\" class=\"wp-image-21258\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image-1024x512.png 1024w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image-300x150.png 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image-768x384.png 768w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">DBS samples are small. Whole blood is complex. Steroid esters can be present at trace levels. And when the signal gets that low, MS<sup>2<\/sup> workflows can run out of specificity before the science runs out of need.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A recent publication from Andreas Thomas, Jasmin Thelen, Panagiotis Sakellariou, and Mario Thevis in <em>Journal of Mass Spectrometry*<\/em> demonstrates a path forward: native steroid ester detection in DBS by LC\u2013MS<sup>3<\/sup> using the Stellar mass spectrometer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The method demonstrates sensitive, selective detection of 17 underivatized steroid esters from DBS without derivatization. More importantly, it shows how Stellar MS enables high-confidence trace-level results by generating multiple diagnostic MS\u00b3 product ions. Scientists can monitor three to five product ions, supporting clean identification and strong product-ion ratio assessment with great confidence at the lowest concentration levels.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-ms-2-alone-is-not-enough\">MS<sup>2<\/sup> alone is not enough<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Steroid ester analysis in DBS is not a routine MS\/MS problem. It is a low-abundance, high-background, high-confidence identification challenge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At sub-ng\/mL concentrations, conventional MS<sup>2<\/sup>-based workflows can struggle to deliver the specificity needed in complex DBS matrices. HRAM MS platforms provide accurate mass and resolution, but accurate mass alone does not automatically deliver highly diagnostic, sequential dissociation data at the required sensitivity. Triple quadrupole MS systems remain powerful for targeted quantitation, but they are not designed to deliver ion trap-based MS<sup>3<\/sup> workflows that can generate additional diagnostic product ions from already-isolated fragments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is where Stellar MS changes the conversation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the <a href=\"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/jms.5188\" target=\"_blank\" rel=\"noreferrer noopener\">published DBS steroid ester method<\/a>, precursor ions were first activated by CID, selected product ions were isolated, and additional dissociation was used to generate cleaner, more diagnostic signals. The result was sensitive, selective detection of native steroid esters from DBS without derivatization.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-the-stellar-ms-difference\">The Stellar MS difference<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Stellar MS is built for targeted MSn performance. Its hybrid quadrupole\u2013dual-pressure linear ion trap architecture enables practical LC\u2013MS<sup>3<\/sup> workflows that are difficult to reproduce on conventional targeted platforms.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The published method used CID at the MS<sup>2<\/sup> stage followed by HCD at the MS<sup>3<\/sup> stage. This CID\u2192HCD strategy helped cut through DBS matrix complexity while maintaining sensitivity at levels that matter for real-world doping control.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CMD\/Reference-Materials\/cs-004613-lsms-stellar-mario-thevis-anti-sports-doping-cs004613-na-en.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Case study: A decade of DBS steroid innovation in the German Sports University Cologne<\/a> adds an important workflow point: ion trap CID at the MS<sup>2<\/sup> stage allowed the same CID setting to be used across steroid esters, while the MS<sup>2<\/sup> product ion selected for MS<sup>3<\/sup> was conserved by base steroid class. That makes method expansion more straightforward as additional anabolic steroid esters are added.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is a major advantage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Other platforms may deliver accurate mass. Triple quadrupoles may deliver robust MRM. Some systems may offer MSn capability. But the differentiator is not MS<sup>3<\/sup> capability alone. It is the ability to improve lower limits of quantitation while matching the limit of identification at the lowest relevant concentrations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In DBS workflows, that distinction matters. When sensitivity outpaces identification confidence, laboratories may detect a low-level signal but still need a follow-up experiment from another DBS spot to satisfy identification criteria. Stellar MS helps close that gap by combining MS<sup>3<\/sup> selectivity, high acquisition speed, and multiple diagnostic product ions. In this workflow, Stellar MS enables more than 10 data points across an approximately 3-second-wide chromatographic peak at full-width half-maximum (FWHM), supporting reproducible peak integration and confident product-ion ratio assessment at trace levels.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-native-analysis-leaner-workflow\">Native analysis, leaner workflow<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Previous DBS steroid ester methods often relied on derivatization to improve ionization efficiency and sensitivity. That adds complexity, time, and workflow burden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The LC\u2013MS<sup>3<\/sup> method eliminates that bottleneck and improves scalability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By analyzing native, underivatized steroid esters, the workflow simplifies sample preparation and preserves the possibility of using the same extract for additional prohibited substances. For anti-doping laboratories, that is more than an efficiency gain. It is a more scalable way to extract greater analytical value from limited DBS sample volume.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-the-data-that-matters\">The data that matters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The publication reports analysis of 17 steroid esters composed of testosterone, nandrolone, and boldenone species. Most analytes extracted from a single DBS spot had detection limits below 0.1 ng\/mL. Recovery rates were reported at 40%\u201380%, and the method used four stable isotope-labeled internal standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The method was also practical across DBS formats, working with both cellulose-based DMPK cards and polymer-based TASSO devices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Selectivity was demonstrated across blank samples from healthy volunteers, with no interfering signals at the relevant retention times. At the proposed 1 ng\/mL level, all target steroid esters were detected in both TASSO and DMPK card samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That is the type of performance DBS workflows require: low-level detection, low-level identification confidence, and practical robustness across sampling devices.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-beyond-steroid-esters\">Beyond steroid esters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The immediate application is direct detection of intact steroid esters in DBS for sports drug testing. But the broader message is bigger.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Scientists working in targeted quantitation and trace-level confirmation are often forced to choose between sensitivity, specificity, throughput, and workflow simplicity. Stellar MS changes that equation by making MS<sup>3<\/sup> practical for small-molecule workflows where MS<sup>2<\/sup> is not selective enough and HRAM MS alone does not solve the problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The German Sports University at Cologne case study also points to future opportunities beyond anabolic steroid esters, including broader small-molecule screening, targeted confirmation workflows, isomer differentiation, and analytes where additional diagnostic product ions can simplify fast, reliable testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-the-bottom-line\">The bottom line<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DBS steroid ester analysis has spent more than a decade fighting the same obstacles: tiny sample volumes, complex matrices, low concentrations, and insufficient specificity from conventional approaches.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stellar MS gives laboratories a practical way forward.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By combining native LC\u2013MS<sup>3<\/sup> analysis, ion trap CID, high acquisition speed, and multiple diagnostic product ions, Stellar MS helps improve lower limits of quantitation while aligning them with limits of identification. That means laboratories can push lower, identify with great confidence, and reduce the risk that a low-level result becomes only a suspicious finding requiring another DBS spot.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For laboratories still trying to solve tomorrow\u2019s DBS challenges with yesterday\u2019s MS<sup>2<\/sup> assumptions, the message is direct:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raise the standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore the Thermo Scientific Stellar mass spectrometer at <a href=\"\/content\/lifetech\/global\/en\/home\/industrial\/mass-spectrometry\/liquid-chromatography-mass-spectrometry-lc-ms\/lc-ms-systems\/orbitrap-lc-ms\/stellar-mass-spectrometer.html\">Stellar Mass Spectrometer<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-references\">References<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">*Thomas, A.; Thelen, J.; Sakellariou, P.; Thevis, M. Simplified Analysis of Native Steroid Esters in Dried Blood Spots by LC\u2013MS\u00b3. <a href=\"https:\/\/doi.org\/10.1002\/jms.5188\" target=\"_blank\" rel=\"noreferrer noopener\"><em>Journal of Mass Spectrometry<\/em> 2025, 60, e5188<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>This article was authored by <a href=\"https:\/\/www.icrav2026.org\/mario-thevis\" target=\"_blank\" rel=\"noreferrer noopener\">Mario Thevis<\/a> as a guest contributor. Views expressed are their own.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Visit us on&nbsp;<a href=\"https:\/\/www.linkedin.com\/showcase\/72003132\/admin\/dashboard\/\" target=\"_blank\" rel=\"noreferrer noopener\"><u>LinkedIn:<\/u><\/a>&nbsp;#StellarMS #SportsDoping #GermanSportsUniversityCologne #MassSpectrometry<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dried blood spot analysis has promised anti-doping laboratories a faster, simpler, and less invasive way to detect steroid ester use. The problem has never been the promise. It has been the analytical reality. DBS samples are small. Whole blood is complex. Steroid esters can be present at trace levels. And when the signal gets that<\/p>\n","protected":false},"author":1760,"featured_media":21258,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[83,34,1829],"tags":[85,35,1787,1826],"division":[],"class_list":["post-21220","post","type-post","status-publish","format-standard","has-post-thumbnail","category-lc-ms","category-mass-spectrometry","category-sports-doping","tag-lc-ms","tag-mass-spectrometry","tag-sports-doping","tag-stellar","entry"],"_selected_authors":[1902],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Stellar MS Raises the Standard for DBS Steroid Ester Detection - AnalyteGuru<\/title>\n<meta name=\"description\" content=\"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Stellar MS Raises the Standard for DBS Steroid Ester Detection\" \/>\n<meta property=\"og:description\" content=\"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-08T08:09:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-08T08:09:25+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Kishore Sridhara\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kishore Sridhara\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/\"},\"author\":{\"name\":\"Kishore Sridhara\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/d09534aeba8bd3e77f2aede3e0a79691\"},\"headline\":\"Stellar MS Raises the Standard for DBS Steroid Ester Detection\",\"datePublished\":\"2026-10-08T08:09:23+00:00\",\"dateModified\":\"2026-10-08T08:09:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/\"},\"wordCount\":1091,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2026\\\/08\\\/Stellar-MS-Raises-the-Standard-blog-image.png\",\"keywords\":[\"LC-MS\",\"Mass Spectrometry\",\"Sports doping\",\"Stellar\"],\"articleSection\":[\"LC-MS\",\"Mass Spectrometry\",\"Sports Doping\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/\",\"name\":\"Stellar MS Raises the Standard for DBS Steroid Ester Detection - AnalyteGuru\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2026\\\/08\\\/Stellar-MS-Raises-the-Standard-blog-image.png\",\"datePublished\":\"2026-10-08T08:09:23+00:00\",\"dateModified\":\"2026-10-08T08:09:25+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/d09534aeba8bd3e77f2aede3e0a79691\"},\"description\":\"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2026\\\/08\\\/Stellar-MS-Raises-the-Standard-blog-image.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2026\\\/08\\\/Stellar-MS-Raises-the-Standard-blog-image.png\",\"width\":1200,\"height\":600,\"caption\":\"Close-up of runners racing on a track, emphasizing speed and high performance.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Stellar MS Raises the Standard for DBS Steroid Ester Detection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/d09534aeba8bd3e77f2aede3e0a79691\",\"name\":\"Kishore Sridhara\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g\",\"caption\":\"Kishore Sridhara\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kishoresridhara\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Stellar MS Raises the Standard for DBS Steroid Ester Detection - AnalyteGuru","description":"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/","og_locale":"en_US","og_type":"article","og_title":"Stellar MS Raises the Standard for DBS Steroid Ester Detection","og_description":"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2026-10-08T08:09:23+00:00","article_modified_time":"2026-10-08T08:09:25+00:00","og_image":[{"width":1200,"height":600,"url":"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","type":"image\/png"}],"author":"Kishore Sridhara","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"Kishore Sridhara","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/"},"author":{"name":"Kishore Sridhara","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/d09534aeba8bd3e77f2aede3e0a79691"},"headline":"Stellar MS Raises the Standard for DBS Steroid Ester Detection","datePublished":"2026-10-08T08:09:23+00:00","dateModified":"2026-10-08T08:09:25+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/"},"wordCount":1091,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","keywords":["LC-MS","Mass Spectrometry","Sports doping","Stellar"],"articleSection":["LC-MS","Mass Spectrometry","Sports Doping"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/","name":"Stellar MS Raises the Standard for DBS Steroid Ester Detection - AnalyteGuru","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","datePublished":"2026-10-08T08:09:23+00:00","dateModified":"2026-10-08T08:09:25+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/d09534aeba8bd3e77f2aede3e0a79691"},"description":"Discover how Stellar MS enables sensitive LC-MS\u00b3 steroid ester detection in dried blood spots with greater selectivity and confidence.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","width":1200,"height":600,"caption":"Close-up of runners racing on a track, emphasizing speed and high performance."},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/stellar-ms-raises-the-standard-for-dbs-steroid-ester-detection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Stellar MS Raises the Standard for DBS Steroid Ester Detection"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/d09534aeba8bd3e77f2aede3e0a79691","name":"Kishore Sridhara","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f15dd5b3e4db468ce0942ee0aa424f5b05ce444d028e597d5644d41097406cdb?s=96&d=mm&r=g","caption":"Kishore Sridhara"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kishoresridhara\/"}]}},"taxonomy_info":{"category":[{"value":83,"label":"LC-MS"},{"value":34,"label":"Mass Spectrometry"},{"value":1829,"label":"Sports Doping"}],"post_tag":[{"value":85,"label":"LC-MS"},{"value":35,"label":"Mass Spectrometry"},{"value":1787,"label":"Sports doping"},{"value":1826,"label":"Stellar"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image-1024x512.png",760,380,true],"author_info":{"display_name":"Kishore Sridhara","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kishoresridhara\/"},"comment_info":0,"category_info":[{"term_id":83,"name":"LC-MS","slug":"lc-ms","term_group":0,"term_taxonomy_id":83,"taxonomy":"category","description":"","parent":0,"count":67,"filter":"raw","meta":[],"cat_ID":83,"category_count":67,"category_description":"","cat_name":"LC-MS","category_nicename":"lc-ms","category_parent":0},{"term_id":34,"name":"Mass Spectrometry","slug":"mass-spectrometry","term_group":0,"term_taxonomy_id":34,"taxonomy":"category","description":"","parent":0,"count":108,"filter":"raw","meta":[],"cat_ID":34,"category_count":108,"category_description":"","cat_name":"Mass Spectrometry","category_nicename":"mass-spectrometry","category_parent":0},{"term_id":1829,"name":"Sports Doping","slug":"sports-doping","term_group":0,"term_taxonomy_id":1829,"taxonomy":"category","description":"","parent":0,"count":8,"filter":"raw","meta":[],"cat_ID":1829,"category_count":8,"category_description":"","cat_name":"Sports Doping","category_nicename":"sports-doping","category_parent":0}],"tag_info":[{"term_id":85,"name":"LC-MS","slug":"lc-ms","term_group":0,"term_taxonomy_id":85,"taxonomy":"post_tag","description":"","parent":0,"count":67,"filter":"raw","meta":[]},{"term_id":35,"name":"Mass Spectrometry","slug":"mass-spectrometry","term_group":0,"term_taxonomy_id":35,"taxonomy":"post_tag","description":"","parent":0,"count":94,"filter":"raw","meta":[]},{"term_id":1787,"name":"Sports doping","slug":"sports-doping","term_group":0,"term_taxonomy_id":1787,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":1826,"name":"Stellar","slug":"stellar","term_group":0,"term_taxonomy_id":1826,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2026\/08\/Stellar-MS-Raises-the-Standard-blog-image.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/21220","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1760"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=21220"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/21220\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/21258"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=21220"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=21220"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=21220"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=21220"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}