{"id":4555,"date":"2023-01-16T14:52:07","date_gmt":"2023-01-16T14:52:07","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/"},"modified":"2026-09-09T01:04:58","modified_gmt":"2026-09-09T01:04:58","slug":"multi-attribute-method-mam-a-biopharmaceutical-basics-overview","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/","title":{"rendered":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview"},"content":{"rendered":"<p class=\"lia-message-body-content\">\n<p><em>This is the second blog post in the Biopharmaceutical Basics series.<\/em><\/p>\n<p>The ultimate goal of biopharmaceutical development and manufacturing is to deliver the highest-quality product at the lowest cost \u2014 in the shortest time possible. However, large molecule drugs are highly complex, leading to analytical challenges throughout the development pipeline to quality control and release.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4557\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og-300x225.jpg\" alt=\"\" width=\"499\" height=\"374\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og-300x225.jpg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og-768x576.jpg 768w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg 999w\" sizes=\"auto, (max-width: 499px) 100vw, 499px\" \/>Monoclonal antibodies (mAbs) and other complex biological drug products, such as <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/pharma-biopharma\/biopharmaceutical-analytical-testing\/antibody-drug-conjugates.html\" target=\"_blank\" rel=\"nofollow noopener\">antibody-drug conjugates (ADCs)<\/a>, must be exhaustively characterized to ensure the safety and efficacy of a batch before release. The Multi-Attribute Method (MAM) aims to address these challenges using the power of high-resolution, accurate-mass (HRAM) mass spectrometry to improve process control for biopharmaceutical manufacturing.<\/p>\n<p>If you\u2019re new to the world of biopharma analysis, here\u2019s a helpful overview on MAM and what\u2019s available today.<\/p>\n<h3 id=\"toc-hId-1154444049\"><strong>What is MAM?<\/strong><\/h3>\n<p>MAM is a peptide mapping-based method that takes advantage of high-resolution mass spectrometric data. High-resolution mass spectrometry provides the accurate mass information aiding identification of product quality attributes and consequent quantitation and monitoring, which leads to a more comprehensive biomolecule process understanding, allowing for better process control in manufacturing. It\u2019s a relatively new analytical approach that is particularly well suited to biotherapeutics QC (<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26186204\" target=\"_blank\" rel=\"noopener nofollow noreferrer\">publication in mAbs [2015]<\/a>).<\/p>\n<h3 id=\"toc-hId-2041947730\"><strong>How does MAM work?<\/strong><\/h3>\n<p>MAM is based on traditional peptide mapping. To begin building the method, the biotherapeutic must first be digested into peptides. This critical step requires 100 percent sequence coverage, high levels of reproducibility, and minimal process-induced modifications (e.g., deamidation and oxidation).<\/p>\n<p>The resulting peptides are separated using liquid chromatography (LC) and detected using high-resolution accurate-mass (HRAM) MS. The data is then processed using sophisticated software tools.<\/p>\n<h3 id=\"toc-hId--1365515885\"><strong>Why is MAM important?<\/strong><\/h3>\n<p>HRAM MS for MAM provides a comprehensive view of the critical quality attributes (CQAs) present in biotherapeutics, down to the individual amino acid of each molecule. Detailed information can be obtained on post-translational modifications (PTMs), glycosylation profile, the presence of low-level sequence variants, and minute concentrations of process impurities. High-resolution accurate-mass data makes access to this detailed information possible without the need for full chromatographic separation.<\/p>\n<p>Another key component of MAM is new peak detection, which enables new peaks (impurities) to be detected when compared to a reference sample. This data analysis step is essential for using MAM as a QC release method. MAM is a singular approach that has the potential to consolidate multiple analyses from QC to batch release, enabling scientists to work toward consistent biotherapeutic products across the process, in line with Quality by Design (QbD) principles.<\/p>\n<h3 id=\"toc-hId--478012204\"><strong>What are the benefits of MAM?<\/strong><\/h3>\n<p>A well-developed MAM enables identification, quantitation, and monitoring of multiple CQAs simultaneously as well as new peak detection. The benefits of an optimized and standardized Multi-Attribute Method for characterization of biologics and later-stage quality control include:<\/p>\n<ul>\n<li>High-resolution MS data for absolute identification and confidence in analytical control over quality<\/li>\n<li>A single method providing the same or superior product quality information instead of many traditional methods and techniques<\/li>\n<li>A single assay that offers cost and time savings, as well as fewer SOPs and instruments to maintain<\/li>\n<li>Offering consistently reliable analytical processes on multiple instruments across different development sites, from research and development to manufacturing and QC<\/li>\n<li>Accepting and standardizing MAM from development into QC space will offer peace of mind when preparing regulatory filings<\/li>\n<\/ul>\n<h3 id=\"toc-hId-409491477\"><strong>A fit-for-purpose MAM solution<\/strong><\/h3>\n<p>Being the leading biotherapeutic solution provider and a trusted partner, Thermo Fisher Scientific has been working closely with industry leaders to develop a seamless, fit-for-purpose MAM solution. <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/development-robust-multi-attribute-method-implementation-in-qc-environment.html\">Read the application note<\/a> to learn how the National Institute of Bioprocessing Research and Training implemented the MAM 2.0 Workflow and evaluated repeatability, reproducibility, and linearity analysis for selected CQAs.<\/p>\n<p>To learn more, contact Thermo Fisher or visit the dedicated <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/pharma-biopharma\/biopharmaceutical-analytical-testing\/multi-attribute-method.html?cid=E.23CMD.PB103.13157.01\">MAM website<\/a>.<\/p>\n<h3 id=\"toc-hId-410138160\"><strong>Additional resources in the Biopharmaceutical Basics blog series<\/strong><\/h3>\n<p><a title=\"Biopharmaceutical Characterization: A Biopharmaceutical Basics Overview\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/biopharmaceutical-characterization-a-biopharmaceutical-basics\/\" target=\"_blank\" rel=\"noopener\">Biopharmaceutical Characterization: A Biopharmaceutical Basics Overview<\/a><\/p>\n<p><a title=\"Gene Therapy: A Biopharmaceutical Basics Overview\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/gene-therapy-a-biopharmaceutical-basics-overview\/\" target=\"_blank\" rel=\"noopener\"><span class=\"lia-link-navigation lia-link-disabled\">Gene Therapy: A Biopharmaceutical Basics Overview<\/span><\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/oligonucleotide-therapeutics-a-biopharmaceutical-basics-overview\/\" target=\"_blank\" rel=\"noopener\">Oligonucleotide Therapeutics: A Biopharmaceutical Basics Overview<\/a><\/p>\n<p><a id=\"link_5\" class=\"page-link lia-link-navigation lia-custom-event\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/mrna-based-therapeutics-and-vaccines-a-biopharmaceutical-basics\/\" target=\"_blank\" rel=\"noopener\">mRNA-based Therapeutics and Vaccines: A Biopharmaceutical Basics Overview<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.<\/p>\n","protected":false},"author":1327,"featured_media":4557,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[38,64,34],"tags":[41,66,35],"division":[],"class_list":["post-4555","post","type-post","status-publish","format-standard","has-post-thumbnail","category-biopharmaceutical","category-mam","category-mass-spectrometry","tag-biopharmaceutical","tag-mam","tag-mass-spectrometry","entry"],"_selected_authors":[1965],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview<\/title>\n<meta name=\"description\" content=\"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview\" \/>\n<meta property=\"og:description\" content=\"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2023-01-16T14:52:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-09T01:04:58+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"999\" \/>\n\t<meta property=\"og:image:height\" content=\"749\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\"},\"headline\":\"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview\",\"datePublished\":\"2023-01-16T14:52:07+00:00\",\"dateModified\":\"2026-09-09T01:04:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/\"},\"wordCount\":655,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/19998-og.jpg\",\"keywords\":[\"Biopharmaceutical\",\"MAM\",\"Mass Spectrometry\"],\"articleSection\":[\"Biopharmaceutical\",\"MAM\",\"Mass Spectrometry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/\",\"name\":\"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/19998-og.jpg\",\"datePublished\":\"2023-01-16T14:52:07+00:00\",\"dateModified\":\"2026-09-09T01:04:58+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\"},\"description\":\"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/19998-og.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/19998-og.jpg\",\"width\":999,\"height\":749},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview","description":"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/","og_locale":"en_US","og_type":"article","og_title":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview","og_description":"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2023-01-16T14:52:07+00:00","article_modified_time":"2026-09-09T01:04:58+00:00","og_image":[{"width":999,"height":749,"url":"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3"},"headline":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview","datePublished":"2023-01-16T14:52:07+00:00","dateModified":"2026-09-09T01:04:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/"},"wordCount":655,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","keywords":["Biopharmaceutical","MAM","Mass Spectrometry"],"articleSection":["Biopharmaceutical","MAM","Mass Spectrometry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/","name":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","datePublished":"2023-01-16T14:52:07+00:00","dateModified":"2026-09-09T01:04:58+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3"},"description":"An overview of what MAM is, why it is important and the solutions it offers in biotherapeutics manufacturing.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","width":999,"height":749},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multi-attribute-method-mam-a-biopharmaceutical-basics-overview\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Multi-Attribute Method (MAM): A Biopharmaceutical Basics Overview"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":38,"label":"Biopharmaceutical"},{"value":64,"label":"MAM"},{"value":34,"label":"Mass Spectrometry"}],"post_tag":[{"value":41,"label":"Biopharmaceutical"},{"value":66,"label":"MAM"},{"value":35,"label":"Mass Spectrometry"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg",760,570,false],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":38,"name":"Biopharmaceutical","slug":"biopharmaceutical","term_group":0,"term_taxonomy_id":38,"taxonomy":"category","description":"","parent":0,"count":68,"filter":"raw","meta":[],"cat_ID":38,"category_count":68,"category_description":"","cat_name":"Biopharmaceutical","category_nicename":"biopharmaceutical","category_parent":0},{"term_id":64,"name":"MAM","slug":"mam","term_group":0,"term_taxonomy_id":64,"taxonomy":"category","description":"","parent":0,"count":11,"filter":"raw","meta":[],"cat_ID":64,"category_count":11,"category_description":"","cat_name":"MAM","category_nicename":"mam","category_parent":0},{"term_id":34,"name":"Mass Spectrometry","slug":"mass-spectrometry","term_group":0,"term_taxonomy_id":34,"taxonomy":"category","description":"","parent":0,"count":108,"filter":"raw","meta":[],"cat_ID":34,"category_count":108,"category_description":"","cat_name":"Mass Spectrometry","category_nicename":"mass-spectrometry","category_parent":0}],"tag_info":[{"term_id":41,"name":"Biopharmaceutical","slug":"biopharmaceutical","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":58,"filter":"raw","meta":[]},{"term_id":66,"name":"MAM","slug":"mam","term_group":0,"term_taxonomy_id":66,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]},{"term_id":35,"name":"Mass Spectrometry","slug":"mass-spectrometry","term_group":0,"term_taxonomy_id":35,"taxonomy":"post_tag","description":"","parent":0,"count":94,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/19998-og.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/4555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=4555"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/4555\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/4557"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=4555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=4555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=4555"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=4555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}