
{"id":4558,"date":"2023-03-13T14:52:07","date_gmt":"2023-03-13T14:52:07","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/"},"modified":"2024-04-16T18:21:45","modified_gmt":"2024-04-16T18:21:45","slug":"multitasking-food-analysis-using-ion-chromatography","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/","title":{"rendered":"Multitasking Food Analysis Using Ion Chromatography (IC)"},"content":{"rendered":"<div class=\"lia-message-body-content\">\n<p>As a young child, I was often scolded for multitasking too many things. Is multitasking a good thing? I\u2019ll let you decide. Just remember that there are many tasks and only one of you! Can you realistically do a good job performing so many tasks at the same time?<\/p>\n<p>Multitasking is often necessary in a workplace with critical timelines, so <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Reference-Materials\/cs-73674-ctl-eurofins-nantes-cs73674-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">productivity<\/a> is crucial. In many food laboratories, meeting timelines is imperative to getting food onto the shelves. Labs must follow strict regulations before food can be approved for human consumption.<img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4561\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg\" alt=\"\" width=\"500\" height=\"317\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg 801w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og-300x190.jpg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og-768x487.jpg 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<h3 id=\"toc-hId-1155096408\"><strong>Testing for pesticides<\/strong><\/h3>\n<p>Pesticides come in many forms. Ionic polar pesticides are particularly challenging. Using ion chromatography with mass spectrometry, we can solve that challenge on one instrument set up with <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-73339-anionic-polar-pesticides-an73339-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">anionic<\/a> and <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-000607-ic-ms-oat-cereal-food-safety-an000607-na-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">cationic<\/a> consumables. It does not require derivatization, which could negatively impact accuracy and reproducibility, and provides a simplified method.<\/p>\n<h3 id=\"toc-hId-2042600089\"><strong>Analyzing with electrochemical detection<\/strong><\/h3>\n<p>We can now <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/food-beverage\/food-beverage-learning-center\/food-analytical-testing-information\/carbohydrate-testing-information.html\" target=\"_blank\" rel=\"nofollow noopener\">analyze carbohydrates<\/a> without derivatization with a gold electrode using the same ion exchange with <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Technical-Notes\/tn-20-hpae-pad-carbohydrates-tn70671-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">high-performance anion exchange chromatography with pulsed amperometric detection (HPAE-PAD).<\/a> By switching the gold electrode to silver and using a different column set, we can detect <a href=\"https:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/AN-54-IEX-Sulfite-Food-Beverage-AN70379-EN.pdf\" target=\"_blank\" rel=\"nofollow noopener\">sulfite<\/a> in food and beverages that can cause allergic reactions. This analysis shows one technology with multiple detection possibilities for various applications.<\/p>\n<h3 id=\"toc-hId--1364863526\"><strong>Analyzing salts<\/strong><\/h3>\n<p>Not only do we find <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-000280-ic-dual-egc-food-labeling-sugars-an000280-na-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">carbohydrate contents listed on food and beverage labeling<\/a>, we also can find salt content and other ionic requirements to sustain health and vitality. Food labeling helps us understand what we consume. It includes many <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-73745-ic-sodium-potassium-calcium-rice-wheat-flours-an73745-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">inorganic cations<\/a> such as sodium, potassium, calcium, magnesium, etc. This analysis uses a simple conductivity setup with an ion chromatography instrument which can also analyze inorganic anions by switching consumables.<\/p>\n<h3 id=\"toc-hId--477359845\"><strong>Testing for stability<\/strong><\/h3>\n<p>We may have established what\u2019s in our food and beverage from the labeling, but what about its stability? Many food testing laboratories will test not only what is in the contents, but also its storage stability in its containers and packaging.<\/p>\n<p>For instance, <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-000164-ic-ics-6000-wine-biogenic-amines-an000164-na-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">biogenic amines<\/a> play a critical role in human and animal physiological functions, but also are related to food spoilage and safety. It is regulated to avoid large intakes into our body, as it can cause hypotension, nausea, increased cardiac output, and more. The analysis is often challenging since most biogenic amines lack chromophoric or fluorophoric groups.<\/p>\n<p>With <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/chromatography\/ion-chromatography-ic.html\" target=\"_blank\" rel=\"nofollow noopener\">ion chromatography (IC)<\/a>, those are not required. To ensure we capture all of them, we can use <a href=\"http:\/\/www.thermoscientific.com\/content\/dam\/tfs\/ATG\/CMD\/CMD%20Documents\/Application%20&amp;%20Technical%20Notes\/Chromatography\/Ion%20Chromatography\/IC%20and%20RFIC%20Columns\/57922-AN183_IC_BiogenicAmines_Food_23Aug07_LPN1889_02.pdf\" target=\"_blank\" rel=\"noopener nofollow noreferrer\">multiple detections<\/a>, such as UV-Vis with integrated pulsed amperometric detection (IPAD) and maybe conductivity with mass spectrometry. Food degradation and spoilage also apply to the formation of certain <a href=\"https:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/AN-1157-HPIC-Organic-Acids-Kombucha-AN72118-EN.pdf\" target=\"_blank\" rel=\"nofollow noopener\">organic acids<\/a>.<\/p>\n<h3 id=\"toc-hId-410143836\"><strong>Analyzing toxic species<\/strong><\/h3>\n<p>Being of Asian descent, I am particularly interested in <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/AN-43255-IC-ICP-MS-Inorganic-Arsenic-Rice-AN43255-EN.pdf\" target=\"_blank\" rel=\"nofollow noopener\">arsenic in rice<\/a>, whereby as it grows, it draws nutrients from the water and soil. It also draws up pollutants into the rice, such as arsenic species. Arsenic compounds can exist in organic and inorganic forms with different toxicities. The inorganic species are far more toxic; therefore, they need to be separated to assess the potential health risk. Using the versatility of <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/chromatography\/ion-chromatography-ic\/ic-icp-ms-speciation-analyzer.html\" target=\"_blank\" rel=\"nofollow noopener\">ion chromatography hyphenated to ICP-MS<\/a>, we can resolve and speciate the arsenic species in the rice. It provides me with great satisfaction that my food is safe.<\/p>\n<h3 id=\"toc-hId-1297647517\"><strong>Productivity<\/strong><\/h3>\n<p>Now that I have demonstrated the many detections and applications that ion chromatography can achieve, can this one technique really perform all those food and beverage testing tasks? I personally think you can \u2014 as I explained to my parents over 45 years ago \u2014 especially if I can automate and use <a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/chromatography\/ion-chromatography-ic\/ion-chromatography-systems\/related-products.html#chromeleon-chromatography-data-system\" target=\"_blank\" rel=\"nofollow noopener\">software<\/a> to help me.<\/p>\n<p>Learn more:<\/p>\n<ul>\n<li><a title=\"Learn more: Thermo Fisher ion chromatography systems\" href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/chromatography\/ion-chromatography-ic\/ion-chromatography-systems.html\" target=\"_blank\" rel=\"nofollow noopener\">Ion chromatography systems<\/a><\/li>\n<li><a href=\"https:\/\/www.technologynetworks.com\/applied-sciences\/videos\/determination-of-cationic-polar-pesticides-in-cereals-with-terri-christison-366097\" target=\"_blank\" rel=\"noopener nofollow noreferrer\">Teach me in 10: Determination of Cationic Polar Pesticides in Cereals With Terri Christison<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/chromatography\/chromatography-learning-center\/ion-chromatography-information\/ion-chromatography-analysis-analyte\/analyzing-carbohydrates-hpae-pad-ion-chromatography.html\" target=\"_blank\" rel=\"nofollow noopener\">Analyzing Carbohydrates by HPAE-PAD Ion Chromatography<\/a><\/li>\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/brochures\/br-000123-na-food-beverage-safety-analysis-br000123-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">Food and Beverage Safety Analysis<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/industrial\/food-beverage\/food-beverage-learning-center.html\" target=\"_blank\" rel=\"nofollow noopener\">Food &amp; Beverage Testing<\/a><\/li>\n<li><a href=\"https:\/\/appslab.thermofisher.com\/\" target=\"_blank\" rel=\"nofollow noopener\">More ion chromatography applications<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">On LinkedIn? Visit our\u00a0<a href=\"https:\/\/www.linkedin.com\/showcase\/chromatography-&amp;-mass-spectrometry\/posts\/?feedView=all\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn page<\/a> #IonChromatography<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.<\/p>\n","protected":false},"author":1327,"featured_media":4561,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[36,17,56],"tags":[37],"division":[],"class_list":["post-4558","post","type-post","status-publish","format-standard","has-post-thumbnail","category-food-beverage","category-ion-chromatography","category-pesticide-analysis","tag-food-beverage","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Multitasking Food Analysis Using Ion Chromatography (IC)<\/title>\n<meta name=\"description\" content=\"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Multitasking Food Analysis Using Ion Chromatography (IC)\" \/>\n<meta property=\"og:description\" content=\"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2023-03-13T14:52:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-16T18:21:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"801\" \/>\n\t<meta property=\"og:image:height\" content=\"508\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\"},\"headline\":\"Multitasking Food Analysis Using Ion Chromatography (IC)\",\"datePublished\":\"2023-03-13T14:52:07+00:00\",\"dateModified\":\"2024-04-16T18:21:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/\"},\"wordCount\":639,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/20643-og.jpg\",\"keywords\":[\"Food &amp; Beverage\"],\"articleSection\":[\"Food and Beverage\",\"Ion Chromatography\",\"Pesticide Analysis\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/\",\"name\":\"Multitasking Food Analysis Using Ion Chromatography (IC)\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/20643-og.jpg\",\"datePublished\":\"2023-03-13T14:52:07+00:00\",\"dateModified\":\"2024-04-16T18:21:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\"},\"description\":\"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/20643-og.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/20643-og.jpg\",\"width\":801,\"height\":508},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/multitasking-food-analysis-using-ion-chromatography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Multitasking Food Analysis Using Ion Chromatography (IC)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/f3e1409c9b7c4b1cd1df8d4b161666d3\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Multitasking Food Analysis Using Ion Chromatography (IC)","description":"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/","og_locale":"en_US","og_type":"article","og_title":"Multitasking Food Analysis Using Ion Chromatography (IC)","og_description":"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2023-03-13T14:52:07+00:00","article_modified_time":"2024-04-16T18:21:45+00:00","og_image":[{"width":801,"height":508,"url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3"},"headline":"Multitasking Food Analysis Using Ion Chromatography (IC)","datePublished":"2023-03-13T14:52:07+00:00","dateModified":"2024-04-16T18:21:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/"},"wordCount":639,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","keywords":["Food &amp; Beverage"],"articleSection":["Food and Beverage","Ion Chromatography","Pesticide Analysis"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/","name":"Multitasking Food Analysis Using Ion Chromatography (IC)","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","datePublished":"2023-03-13T14:52:07+00:00","dateModified":"2024-04-16T18:21:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3"},"description":"Multitasking analysis of toxins in food and beverages can be automated with ion chromatography and the right software.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","width":801,"height":508},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/multitasking-food-analysis-using-ion-chromatography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Multitasking Food Analysis Using Ion Chromatography (IC)"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/f3e1409c9b7c4b1cd1df8d4b161666d3","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":36,"label":"Food and Beverage"},{"value":17,"label":"Ion Chromatography"},{"value":56,"label":"Pesticide Analysis"}],"post_tag":[{"value":37,"label":"Food &amp; Beverage"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg",760,482,false],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":36,"name":"Food and Beverage","slug":"food-beverage","term_group":0,"term_taxonomy_id":36,"taxonomy":"category","description":"","parent":0,"count":67,"filter":"raw","meta":[],"cat_ID":36,"category_count":67,"category_description":"","cat_name":"Food and Beverage","category_nicename":"food-beverage","category_parent":0},{"term_id":17,"name":"Ion Chromatography","slug":"ion-chromatography","term_group":0,"term_taxonomy_id":17,"taxonomy":"category","description":"","parent":0,"count":72,"filter":"raw","meta":[],"cat_ID":17,"category_count":72,"category_description":"","cat_name":"Ion Chromatography","category_nicename":"ion-chromatography","category_parent":0},{"term_id":56,"name":"Pesticide Analysis","slug":"pesticide-analysis","term_group":0,"term_taxonomy_id":56,"taxonomy":"category","description":"","parent":0,"count":12,"filter":"raw","meta":[],"cat_ID":56,"category_count":12,"category_description":"","cat_name":"Pesticide Analysis","category_nicename":"pesticide-analysis","category_parent":0}],"tag_info":[{"term_id":37,"name":"Food &amp; Beverage","slug":"food-beverage","term_group":0,"term_taxonomy_id":37,"taxonomy":"post_tag","description":"","parent":0,"count":31,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/20643-og.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/4558","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=4558"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/4558\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/4561"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=4558"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=4558"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=4558"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=4558"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}