{"id":6382,"date":"2022-03-23T15:05:17","date_gmt":"2022-03-23T15:05:17","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/"},"modified":"2026-09-09T01:02:37","modified_gmt":"2026-09-09T01:02:37","slug":"understand-your-lipid-nanoparticle-composition-with-a-universal","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/","title":{"rendered":"Understand Your Lipid Nanoparticle Composition with a Universal Detector"},"content":{"rendered":"<div class=\"lia-message-body-content\">\n<p><span class=\"lia-inline-image-display-wrapper lia-image-align-center\" style=\"width: 800px\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-12086 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og-1.jpg\" alt=\"\" width=\"800\" height=\"394\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og-1.jpg 800w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og-1-300x148.jpg 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og-1-768x378.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/span><\/p>\n<h3 id=\"toc-hId-1154319118\"><strong>The role of lipid nanoparticles<\/strong><\/h3>\n<p>Lipid nanoparticles (LNP) play a key role in mRNA-based vaccine and therapeutics. LNPs encapsulate mRNAs, protecting them from degradation before the uptake by target cells or tissues. The identification, ratio and purity of the lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy, and thus must be accurately monitored.<\/p>\n<h3 id=\"toc-hId-2041822799\"><strong>Why do you need a charged aerosol detector?<\/strong><\/h3>\n<p>Traditional UV detection can\u2019t be used, as lipids have no chromophore. A <a href=\"https:\/\/www.thermofisher.com\/document-connect\/document-connect.html?url=https%3A%2F%2Fassets.thermofisher.com%2FTFS-Assets%2FCMD%2Fbrochures%2FBR-70735-LC-Corona-Veo-CAD-BR70735-EN.pdf\" target=\"_blank\" rel=\"nofollow noopener\">charged aerosol detector<\/a> (CAD) generates uniform signal response for any non- or semi-volatile compound, making it an ideal system for LNP compositional analysis. CAD also is more sensitive than alternative lipid detection systems, such as refractive index or evaporative light scattering detectors (ELSD). Over the past few years, charged aerosol detection has been adopted as the standard technology for COVID-19 vaccine release assays at both Moderna and Pfizer\/BioNTech.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-12409\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Vaccine-Banner-032322-1.jpg\" alt=\"\" width=\"425\" height=\"91\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Vaccine-Banner-032322-1.jpg 400w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Vaccine-Banner-032322-1-300x65.jpg 300w\" sizes=\"auto, (max-width: 425px) 100vw, 425px\" \/>Sissi White, senior product applications specialist at Thermo Fisher Scientific, recently developed a simple UHPLC-CAD method for the characterization and quantification of lipid components of LNP formulations.<\/p>\n<p>With the method:<\/p>\n<ul>\n<li>Baseline separation was achieved for lipids and their impurities within 10 minutes, using a Thermo Scientific\u2122 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/27826-252130?SID=srch-srp-27826-252130\" target=\"_blank\" rel=\"nofollow noopener\">Accucore\u2122 C30 column<\/a> on a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAAGABHFAPUMBHV?SID=srch-hj-IQLAAAGABHFAPUMBHV\" target=\"_blank\" rel=\"nofollow noopener\">Thermo Scientific\u2122 Vanquish\u2122 Flex UHPLC system<\/a>.<\/li>\n<li>Sensitive and reproducible detection was obtained for all lipids, including cholesterol, with detection limits at ~10 ug\/mL, using a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/VF-D20-A?SID=srch-hj-VF-D20-A\" target=\"_blank\" rel=\"nofollow noopener\">Vanquish charged aerosol detector<\/a>.<\/li>\n<\/ul>\n<p><span class=\"lia-inline-image-display-wrapper lia-image-align-center\" style=\"width: 999px\"><span class=\"lia-inline-image-caption\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12413 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Chromatograms-using-FA-method-032322-1.png\" alt=\"\" width=\"998\" height=\"464\" srcset=\"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Chromatograms-using-FA-method-032322-1.png 998w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Chromatograms-using-FA-method-032322-1-300x139.png 300w, https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/Chromatograms-using-FA-method-032322-1-768x357.png 768w\" sizes=\"auto, (max-width: 998px) 100vw, 998px\" \/>Figure 3. Overlaid chromatograms of calibration standards using the FA method<\/span><\/span><\/p>\n<p><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-000465-uhplc-cad-lipid-nanoparticle-composition-an000465-na-en.pdf\" target=\"_blank\" rel=\"nofollow noopener\">Download the application note to learn more<\/a>.<\/p>\n<p>Visit <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/pharma-biopharma\/biopharmaceutical-analytical-testing\/vaccine-characterization.html\" target=\"_blank\" rel=\"nofollow noopener\">our new vaccine webpages<\/a> to discover a full suite of analytical solutions for vaccine characterization.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The identification, ratio and purity of the lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy, and thus must be accurately monitored.<\/p>\n","protected":false},"author":1327,"featured_media":6384,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[9,2],"tags":[10,15],"division":[],"class_list":{"0":"post-6382","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-charged-aerosol-detection","8":"category-liquid-chromatography","9":"tag-charged-aerosol-detection","10":"tag-uhplc","11":"entry"},"_selected_authors":[1965],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Understand Lipid Nanoparticle Composition with a Universal Detector<\/title>\n<meta name=\"description\" content=\"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understand Your Lipid Nanoparticle Composition with a Universal Detector\" \/>\n<meta property=\"og:description\" content=\"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/\" \/>\n<meta property=\"og:site_name\" content=\"AnalyteGuru\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ChromatographySolutions\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-23T15:05:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-09T01:02:37+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"394\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AnalyteGuru Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:site\" content=\"@ChromSolutions\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AnalyteGuru Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/\"},\"author\":{\"name\":\"AnalyteGuru Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"headline\":\"Understand Your Lipid Nanoparticle Composition with a Universal Detector\",\"datePublished\":\"2022-03-23T15:05:17+00:00\",\"dateModified\":\"2026-09-09T01:02:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/\"},\"wordCount\":272,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/15397-og.jpg\",\"keywords\":[\"Charged Aerosol Detection\",\"UHPLC\"],\"articleSection\":[\"Charged Aerosol Detection\",\"Liquid Chromatography\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/\",\"name\":\"Understand Lipid Nanoparticle Composition with a Universal Detector\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/15397-og.jpg\",\"datePublished\":\"2022-03-23T15:05:17+00:00\",\"dateModified\":\"2026-09-09T01:02:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\"},\"description\":\"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/15397-og.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/wp-content\\\/uploads\\\/sites\\\/25\\\/2023\\\/06\\\/15397-og.jpg\",\"width\":800,\"height\":394},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/analyteguru\\\/understand-your-lipid-nanoparticle-composition-with-a-universal\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understand Your Lipid Nanoparticle Composition with a Universal Detector\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/\",\"name\":\"AnalyteGuru\",\"description\":\"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/analyteguru\\\/#\\\/schema\\\/person\\\/47226155467d66d692f24162ee320270\",\"name\":\"AnalyteGuru Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g\",\"caption\":\"AnalyteGuru Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kerrycolligan\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Understand Lipid Nanoparticle Composition with a Universal Detector","description":"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/","og_locale":"en_US","og_type":"article","og_title":"Understand Your Lipid Nanoparticle Composition with a Universal Detector","og_description":"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.","og_url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/","og_site_name":"AnalyteGuru","article_publisher":"https:\/\/www.facebook.com\/ChromatographySolutions","article_published_time":"2022-03-23T15:05:17+00:00","article_modified_time":"2026-09-09T01:02:37+00:00","og_image":[{"width":800,"height":394,"url":"http:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","type":"image\/jpeg"}],"author":"AnalyteGuru Staff","twitter_card":"summary_large_image","twitter_creator":"@ChromSolutions","twitter_site":"@ChromSolutions","twitter_misc":{"Written by":"AnalyteGuru Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/"},"author":{"name":"AnalyteGuru Staff","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"headline":"Understand Your Lipid Nanoparticle Composition with a Universal Detector","datePublished":"2022-03-23T15:05:17+00:00","dateModified":"2026-09-09T01:02:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/"},"wordCount":272,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","keywords":["Charged Aerosol Detection","UHPLC"],"articleSection":["Charged Aerosol Detection","Liquid Chromatography"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/","url":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/","name":"Understand Lipid Nanoparticle Composition with a Universal Detector","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","datePublished":"2022-03-23T15:05:17+00:00","dateModified":"2026-09-09T01:02:37+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270"},"description":"The identification, ratio and purity of lipid components in LNP formulation are regarded as critical quality attributes (CQAs) for safety and efficacy.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","width":800,"height":394},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/understand-your-lipid-nanoparticle-composition-with-a-universal\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/analyteguru\/"},{"@type":"ListItem","position":2,"name":"Understand Your Lipid Nanoparticle Composition with a Universal Detector"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#website","url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/","name":"AnalyteGuru","description":"Your educational resource for biopharma, pharma, environmental, food and agriculture, industrial, and clinical labs","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/analyteguru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/analyteguru\/#\/schema\/person\/47226155467d66d692f24162ee320270","name":"AnalyteGuru Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d716c4c68d79e076572f67bcc11df0ef8db404f6c3463e9cfd3d20514a881439?s=96&d=mm&r=g","caption":"AnalyteGuru Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"}]}},"taxonomy_info":{"category":[{"value":9,"label":"Charged Aerosol Detection"},{"value":2,"label":"Liquid Chromatography"}],"post_tag":[{"value":10,"label":"Charged Aerosol Detection"},{"value":15,"label":"UHPLC"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg",760,374,false],"author_info":{"display_name":"AnalyteGuru Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kerrycolligan\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Charged Aerosol Detection","slug":"charged-aerosol-detection","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":16,"filter":"raw","meta":[],"cat_ID":9,"category_count":16,"category_description":"","cat_name":"Charged Aerosol Detection","category_nicename":"charged-aerosol-detection","category_parent":0},{"term_id":2,"name":"Liquid Chromatography","slug":"liquid-chromatography","term_group":0,"term_taxonomy_id":2,"taxonomy":"category","description":"","parent":0,"count":91,"filter":"raw","meta":[],"cat_ID":2,"category_count":91,"category_description":"","cat_name":"Liquid Chromatography","category_nicename":"liquid-chromatography","category_parent":0}],"tag_info":[{"term_id":10,"name":"Charged Aerosol Detection","slug":"charged-aerosol-detection","term_group":0,"term_taxonomy_id":10,"taxonomy":"post_tag","description":"","parent":0,"count":14,"filter":"raw","meta":[]},{"term_id":15,"name":"UHPLC","slug":"uhplc","term_group":0,"term_taxonomy_id":15,"taxonomy":"post_tag","description":"","parent":0,"count":36,"filter":"raw","meta":[]}],"jetpack_sharing_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/analyteguru\/wp-content\/uploads\/sites\/25\/2023\/06\/15397-og.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/6382","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/users\/1327"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/comments?post=6382"}],"version-history":[{"count":1,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/6382\/revisions"}],"predecessor-version":[{"id":21368,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/posts\/6382\/revisions\/21368"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media\/6384"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/media?parent=6382"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/categories?post=6382"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/tags?post=6382"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/analyteguru\/wp-json\/wp\/v2\/division?post=6382"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}