{"id":152,"date":"2018-11-27T23:50:22","date_gmt":"2018-11-27T23:50:22","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/2018\/11\/27\/a-new-era-for-determining-small-molecule-structure-determination\/"},"modified":"2018-11-27T23:50:22","modified_gmt":"2018-11-27T23:50:22","slug":"a-new-era-for-determining-small-molecule-structure-determination","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/","title":{"rendered":"A New Era for Determining Small Molecule Structure Determination"},"content":{"rendered":"<p>In the last few weeks, there\u2019s been a lot of excitement about micro-electron diffraction, MicroED for short, within the chemist community. This electron microscopy method takes small molecule structure determination to a whole new level. As <a href=\"https:\/\/ter.li\/6v68z7\">Hosea Nelson<\/a>, professor of Chemistry and Biochemistry at University of California, Los Angeles (UCLA) and co-author of <a href=\"https:\/\/ter.li\/7fvt0t\">a recent MicroED article<\/a>, says, \u201cUsing this technique, the speed at which we can formulate potentially life-saving drugs will be greatly accelerated; it will be like going from riding a tricycle to driving a Ferrari.\u201d<\/p>\n<div style=\"width: 665px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: auto;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed-1.png\" width=\"655\" height=\"238\" \/><p class=\"wp-caption-text\">The process of applying MicroED to small molecule structural analysis via ChemRxiv<\/p><\/div>\n<h2>A Bit of Background<\/h2>\n<p>For decades, scientists have been using a technique called x-ray crystallography for structural determination where X-ray beams are transmitted through a crystal, causing the beam to diffract based on its crystal lattice structure. The symmetry of the diffraction pattern and the intensity of the spots provides information on how the atoms or molecules are arranged in the crystal, enabling the scientist to determine the molecular structure.<\/p>\n<p>While this technique is widely adopted, it has its limitations. The crystals have to be uniform and relatively large (~10mu), and the process of creating optimal crystals from new materials can be slow and even impossible for certain samples. Moreover, for smaller crystals, the total x-ray dose per volume increases dramatically, leading to a fast degradation under the x-ray beam, especially in organic compounds. Earlier approaches of 3D electron diffraction used step-by-step tilt methods, which led to limited success in time-to-data and electron dose reduction.<\/p>\n<div style=\"width: 596px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: auto;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1.png\" width=\"586\" height=\"308\" \/><p class=\"wp-caption-text\">MicroED structure of lysozyme at 2.9 \u00c5 resolution via DOI 10.7554\/eLife.01345<\/p><\/div>\n<p>&nbsp;<\/p>\n<h2>Why MicroED?<\/h2>\n<p>Dr. Tamir Gonen, a leader in the electron crystallography and cryo-EM field, and his team pushed the limits of the cutting-edge instrumentation by analyzing crystallized protein samples that were too small and sensitive to observe with traditional X-ray diffraction. How? By developing a new technique called MicroED, <a href=\"https:\/\/cryoem.ucla.edu\/uploads\/image\/pdfs\/2013_shi.pdf\">initially published in 2013<\/a>. Using electrons instead of x-rays, they were able to collect diffraction information fast and with minimum dose, in turn allowing them to examine much smaller crystals than what is needed for X-ray diffraction. The progress in stage performance and sensor technology in electron microscopy enabled this research.<\/p>\n<p>Since then, Gonen has further improved and optimized MicroED. Last month, researchers took this technology to the next level by applying it to small chemical crystals directly from their powder form. <a href=\"https:\/\/ter.li\/00mzju\">Gonen<\/a> and his joint UCLA- and California Institute of Technology (Caltech)-based team used our <a href=\"https:\/\/ter.li\/bdrft6\">Thermo Scientific Talos Arctica<\/a> to determine the structure of a single nanocrystal of acetaminophen, ibuprofen and other chemicals directly from the shelf.<\/p>\n<blockquote><p>It only took three minutes to collect the data, allowing them to produce a high-resolution atomic structure within an impressive 30 minutes.<\/p><\/blockquote>\n<p>In <a href=\"https:\/\/ter.li\/i4ipy4\">another paper<\/a> published almost simultaneously, a Swiss\/German group led by Tim Gruene at the Paul Scherrer Institut found similar results. Like Gonen\u2019s team, they were able to determine the structure of active pharmaceutical ingredients straight from a crushed pill.<\/p>\n<div style=\"width: 640px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed3-1.jpg\" width=\"630\" height=\"390\" \/><p class=\"wp-caption-text\">Single\u2010crystal structure from a powder blend via DOI 10.1002\/anie.201811318<\/p><\/div>\n<h2>The Impact of MicroED on Science<\/h2>\n<p>Having the ability to solve the structure of small molecules can be applied in many fields, from oil and gas to agriculture and food to organic chemistry. Because only nanocrystals are required and big single crystals do not have to be synthesized, MicroED offers a fast track to determine the crystal structure of new materials. While it\u2019s hard to judge its impact on all areas of science, MicroED promises a number of exciting potential applications:<\/p>\n<ul>\n<li>Pharmaceutical companies can use the method both in developing new drugs and in ensuring the potency of existing drugs.<\/li>\n<li>Small molecule researchers in areas like inorganic chemistry and polymer research can quickly characterize the structures of their nano-crystalline chemical compounds.<\/li>\n<\/ul>\n<p>Interested in learning more about MicroED and how it\u2019s enabling new science? Watch our <a href=\"https:\/\/ter.li\/op97os\">Intro to MicroED presentation<\/a>:<\/p>\n<p style=\"text-align: center\"><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/mm2018-2.png\" \/><\/p>\n<p style=\"text-align: center\"><em><a href=\"https:\/\/ter.li\/lohgiv\">View more presentations from M&amp;M 2018<\/a><\/em><\/p>\n<p>Stay up-to-date on other industry news by following us on Twitter <a href=\"https:\/\/ter.li\/fp7whu\">(@thermosciEMSpec<\/a>).<\/p>\n<p><em>Chris Budde is Senior Director of Business Segment, Electron Microscopy at Thermo Fisher Scientific. Co-authored by\u00a0<\/em><em>Bert Freitag is Principal Scientist, Electron Microscopy at Thermo Fisher Scientific.<\/em><\/p>\n<p>To learn more about microED, <a href=\"https:\/\/ter.li\/vbbd6k\">fill out this form<\/a> to speak with an expert.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the last few weeks, there\u2019s been a lot of excitement about micro-electron diffraction, MicroED for short, within the chemist community. This electron microscopy method takes small molecule structure determination to a whole new level. As Hosea Nelson, professor of Chemistry and Biochemistry at University of California, Los Angeles (UCLA) and co-author of a recent<\/p>\n","protected":false},"author":859,"featured_media":157,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[24,14],"tags":[42,61,62,15,16,17,26,63,64,65,66,31,32,67,68],"division":[],"class_list":["post-152","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cryo-electron-microscopy-cryo-em","category-electron-microscopy-101","tag-caltech","tag-chemistry","tag-chemrxiv","tag-cryo-electron-microscopy","tag-cryo-em","tag-electron-microscopy","tag-fei","tag-micro-electron-diffraction","tag-microed","tag-talos-arctica","tag-tamir-gonen","tag-thermo-fisher-scientific","tag-thermo-scientific","tag-tim-gruene","tag-ucla","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>A New Era for Determining Small Molecule Structure Determination - Life in Atomic Resolution<\/title>\n<meta name=\"description\" content=\"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A New Era for Determining Small Molecule Structure Determination\" \/>\n<meta property=\"og:description\" content=\"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in Atomic Resolution\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2018-11-27T23:50:22+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"586\" \/>\n\t<meta property=\"og:image:height\" content=\"308\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Chris Budde\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chris Budde\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/\"},\"author\":{\"name\":\"Chris Budde\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/64c3903a66805f7306315d68da0d7577\"},\"headline\":\"A New Era for Determining Small Molecule Structure Determination\",\"datePublished\":\"2018-11-27T23:50:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/\"},\"wordCount\":734,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/microed2-1-1.png\",\"keywords\":[\"Caltech\",\"chemistry\",\"ChemRxiv\",\"cryo-electron microscopy\",\"cryo-EM\",\"Electron microscopy\",\"FEI\",\"micro-electron diffraction\",\"MicroED\",\"Talos Arctica\",\"Tamir Gonen\",\"Thermo Fisher Scientific\",\"Thermo Scientific\",\"Tim Gruene\",\"UCLA\"],\"articleSection\":[\"Cryo-Electron Microscopy (Cryo-EM)\",\"Electron Microscopy 101\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/\",\"name\":\"A New Era for Determining Small Molecule Structure Determination - Life in Atomic Resolution\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/microed2-1-1.png\",\"datePublished\":\"2018-11-27T23:50:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/64c3903a66805f7306315d68da0d7577\"},\"description\":\"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/microed2-1-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/microed2-1-1.png\",\"width\":586,\"height\":308},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/a-new-era-for-determining-small-molecule-structure-determination\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A New Era for Determining Small Molecule Structure Determination\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\",\"name\":\"Life in Atomic Resolution\",\"description\":\"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/64c3903a66805f7306315d68da0d7577\",\"name\":\"Chris Budde\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g\",\"caption\":\"Chris Budde\"},\"sameAs\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/microscopy\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chrisbudde\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"A New Era for Determining Small Molecule Structure Determination - Life in Atomic Resolution","description":"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/","og_locale":"en_US","og_type":"article","og_title":"A New Era for Determining Small Molecule Structure Determination","og_description":"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.","og_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/","og_site_name":"Life in Atomic Resolution","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2018-11-27T23:50:22+00:00","og_image":[{"width":586,"height":308,"url":"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","type":"image\/png"}],"author":"Chris Budde","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chris Budde","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#article","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/"},"author":{"name":"Chris Budde","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/64c3903a66805f7306315d68da0d7577"},"headline":"A New Era for Determining Small Molecule Structure Determination","datePublished":"2018-11-27T23:50:22+00:00","mainEntityOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/"},"wordCount":734,"commentCount":0,"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","keywords":["Caltech","chemistry","ChemRxiv","cryo-electron microscopy","cryo-EM","Electron microscopy","FEI","micro-electron diffraction","MicroED","Talos Arctica","Tamir Gonen","Thermo Fisher Scientific","Thermo Scientific","Tim Gruene","UCLA"],"articleSection":["Cryo-Electron Microscopy (Cryo-EM)","Electron Microscopy 101"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/","name":"A New Era for Determining Small Molecule Structure Determination - Life in Atomic Resolution","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website"},"primaryImageOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#primaryimage"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","datePublished":"2018-11-27T23:50:22+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/64c3903a66805f7306315d68da0d7577"},"description":"Micro-electron diffraction, MicroED for short, is an electron microscopy method that is taking small molecule structure determination to a whole new level.","breadcrumb":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","width":586,"height":308},{"@type":"BreadcrumbList","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/a-new-era-for-determining-small-molecule-structure-determination\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/"},{"@type":"ListItem","position":2,"name":"A New Era for Determining Small Molecule Structure Determination"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/","name":"Life in Atomic Resolution","description":"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/64c3903a66805f7306315d68da0d7577","name":"Chris Budde","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bb99a238e94c7ed341388b346859c445725cd4cb12b1e55e7319e06a63bb8141?s=96&d=mm&r=g","caption":"Chris Budde"},"sameAs":["https:\/\/admin.acceleratingscience.com\/microscopy"],"url":"https:\/\/admin.acceleratingscience.com\/author\/chrisbudde\/"}]}},"taxonomy_info":{"category":[{"value":24,"label":"Cryo-Electron Microscopy (Cryo-EM)"},{"value":14,"label":"Electron Microscopy 101"}],"post_tag":[{"value":42,"label":"Caltech"},{"value":61,"label":"chemistry"},{"value":62,"label":"ChemRxiv"},{"value":15,"label":"cryo-electron microscopy"},{"value":16,"label":"cryo-EM"},{"value":17,"label":"Electron microscopy"},{"value":26,"label":"FEI"},{"value":63,"label":"micro-electron diffraction"},{"value":64,"label":"MicroED"},{"value":65,"label":"Talos Arctica"},{"value":66,"label":"Tamir Gonen"},{"value":31,"label":"Thermo Fisher Scientific"},{"value":32,"label":"Thermo Scientific"},{"value":67,"label":"Tim Gruene"},{"value":68,"label":"UCLA"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png",586,308,false],"author_info":{"display_name":"Chris Budde","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chrisbudde\/"},"comment_info":0,"category_info":[{"term_id":24,"name":"Cryo-Electron Microscopy (Cryo-EM)","slug":"cryo-electron-microscopy-cryo-em","term_group":0,"term_taxonomy_id":24,"taxonomy":"category","description":"","parent":0,"count":79,"filter":"raw","meta":[],"cat_ID":24,"category_count":79,"category_description":"","cat_name":"Cryo-Electron Microscopy (Cryo-EM)","category_nicename":"cryo-electron-microscopy-cryo-em","category_parent":0},{"term_id":14,"name":"Electron Microscopy 101","slug":"electron-microscopy-101","term_group":0,"term_taxonomy_id":14,"taxonomy":"category","description":"","parent":0,"count":5,"filter":"raw","meta":[],"cat_ID":14,"category_count":5,"category_description":"","cat_name":"Electron Microscopy 101","category_nicename":"electron-microscopy-101","category_parent":0}],"tag_info":[{"term_id":42,"name":"Caltech","slug":"caltech","term_group":0,"term_taxonomy_id":42,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":61,"name":"chemistry","slug":"chemistry","term_group":0,"term_taxonomy_id":61,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":62,"name":"ChemRxiv","slug":"chemrxiv","term_group":0,"term_taxonomy_id":62,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":15,"name":"cryo-electron microscopy","slug":"cryo-electron-microscopy","term_group":0,"term_taxonomy_id":15,"taxonomy":"post_tag","description":"","parent":0,"count":62,"filter":"raw","meta":[]},{"term_id":16,"name":"cryo-EM","slug":"cryo-em","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":63,"filter":"raw","meta":[]},{"term_id":17,"name":"Electron microscopy","slug":"electron-microscopy","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw","meta":[]},{"term_id":26,"name":"FEI","slug":"fei","term_group":0,"term_taxonomy_id":26,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":63,"name":"micro-electron diffraction","slug":"micro-electron-diffraction","term_group":0,"term_taxonomy_id":63,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":64,"name":"MicroED","slug":"microed","term_group":0,"term_taxonomy_id":64,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":65,"name":"Talos Arctica","slug":"talos-arctica","term_group":0,"term_taxonomy_id":65,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":66,"name":"Tamir Gonen","slug":"tamir-gonen","term_group":0,"term_taxonomy_id":66,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":31,"name":"Thermo Fisher Scientific","slug":"thermo-fisher-scientific","term_group":0,"term_taxonomy_id":31,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]},{"term_id":32,"name":"Thermo Scientific","slug":"thermo-scientific","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","meta":[]},{"term_id":67,"name":"Tim Gruene","slug":"tim-gruene","term_group":0,"term_taxonomy_id":67,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":68,"name":"UCLA","slug":"ucla","term_group":0,"term_taxonomy_id":68,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":1854,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-100-kv-high-resolution-cryo-em-single-particle-analysis\/","url_meta":{"origin":152,"position":0},"title":"Advances in high-resolution cryo-EM at 100 kV","author":"Swarnim Rawat","date":"February 5, 2026","format":false,"excerpt":"100 kV cryo-TEM enables high-resolution single particle analysis Within the past decade, cryo-electron microscopy (cryo-EM) techniques have revolutionized structural biology by enabling the visualization of challenging molecular and sub-cellular structures in their near-native states at high resolution. These valuable observations have, until recently, been relegated to advanced 300 kV instruments\u2026","rel":"","context":"In &quot;Cryo-Electron Microscopy (Cryo-EM)&quot;","block_context":{"text":"Cryo-Electron Microscopy (Cryo-EM)","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/"},"img":{"alt_text":"Advances in high-resolution cryo-EM at 100 kV","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1935,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/fragment-based-drug-discovery-of-drug-targets-membrane-proteins-with-cryo-em\/","url_meta":{"origin":152,"position":1},"title":"Fragment based drug discovery meets challenging drug targets with high-throughput cryo-EM\u00a0","author":"Swarnim Rawat","date":"December 12, 2025","format":false,"excerpt":"Benefits of FBDD in the search for novel therapeutics\u00a0 Fragment-based drug discovery (FBDD) is a method that screens a large quantity of protein fragments for their potential as small molecule therapeutics. This approach was previously hampered by the slow throughput of crystallization for the characterization of potential leads. The increasing\u2026","rel":"","context":"In &quot;Cryo EM Drug Discovery&quot;","block_context":{"text":"Cryo EM Drug Discovery","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-drug-discovery\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2143,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/microscopy-image-analysis-with-amira-software-ai-in-cell-biology\/","url_meta":{"origin":152,"position":2},"title":"Four ways AI is making microscopy image analysis easier for cell biologists","author":"Alejandra Sanchez-Erostegui","date":"October 14, 2026","format":false,"excerpt":"Key takeaways Modern microscopes are capable of generating large volumes of high-resolution data, which is highly valuable for cell biology research, but also makes it increasingly more laborious and difficult to extract meaningful scientific information from the whole dataset.\u00a0 Artificial intelligence is well positioned to support this work by streamlining\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Four ways AI is making microscopy image analysis easier for cell biologists.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2117,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-cryo-electron-tomography-expand-the-capabilities-of-quantitative-cell-biology\/","url_meta":{"origin":152,"position":3},"title":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology","author":"Vinay S","date":"September 29, 2026","format":false,"excerpt":"Key takeaways Cryo-electron tomography has largely been seen as a qualitative method because cryo-ET data segmentation has been a highly intensive, manual process. Recent advances in deep-learning-based segmentation have expanded the capabilities of cryo-electron tomography, supporting quantitative analysis of cellular structures. A recent webinar by Professor Danielle Grotjahn highlights how\u2026","rel":"","context":"In &quot;Cryo EM Techniques&quot;","block_context":{"text":"Cryo EM Techniques","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-techniques\/"},"img":{"alt_text":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2172,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","url_meta":{"origin":152,"position":4},"title":"What is Subtomogram Averaging?","author":"Swarnim Rawat","date":"October 19, 2026","format":false,"excerpt":"Turning crowded cryo-ET data into structural insight with subtomogram averaging Cryo-electron tomography (cryo-ET) is capable of capturing detailed, three-dimensional views of vitrified biological samples, supporting a broad range of life sciences research. Subtomogram averaging helps refine that crowded data for clearer structural insight by finding repeated particles, extracting them as\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/cancer-research\/"},"img":{"alt_text":"Social Cryo EM","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2016,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/how-artificial-intelligence-ai-improves-image-analysis-workflows-in-life-sciences\/","url_meta":{"origin":152,"position":5},"title":"How artificial intelligence (AI) improves image analysis workflows in life sciences","author":"Vinay S","date":"June 2, 2026","format":false,"excerpt":"Image acquisition is not the end of the story\u2014it is the starting point. Once images are captured, researchers typically move into preprocessing to improve quality, then they perform visualization, segmentation, and quantitative analysis to extract meaningful measurements. The goal is simple: turn images into understanding. In practice, however, image analysis\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"How artificial intelligence (AI) improves image analysis workflows in life sciences","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/microed2-1-1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/users\/859"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/comments?post=152"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/152\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media\/157"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media?parent=152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/categories?post=152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/tags?post=152"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/division?post=152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}