{"id":1749,"date":"2025-06-20T16:59:23","date_gmt":"2025-06-20T16:59:23","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/?p=1749"},"modified":"2025-09-03T09:18:30","modified_gmt":"2025-09-03T09:18:30","slug":"whole-lung-analysis-with-micro-optical-sectioning-tomography","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/","title":{"rendered":"A novel strategy for whole lung analysis with micro-optical sectioning tomography"},"content":{"rendered":"<h2 style=\"font-size: 100%\"><strong>Analysis of lung diseases<\/strong><\/h2>\n\n\n<p>Chronic obstructive pulmonary disease, lower respiratory infections, and lung cancer are among the leading causes of mortality worldwide. A drug delivery methodology called dry powder inhalation (DPI) is being explored as a promising treatment method against pulmonary diseases.<\/p>\n\n\n\n<p>For DPI to be considered effective, it is crucial that the drug is precisely deposited at the desired location within the respiratory tract, which also helps to limit side effects. Although <em>in vitro<\/em> research has advanced significantly, a gap exists between particle-distribution simulations and the actual distribution of particles in vivo. Beyond this, there is also a need to fully understand the 3D architecture of lungs to ensure accurate particle distribution <em>in situ<\/em>.<\/p>\n\n\n<h2 style=\"font-size: 100%\"><strong>Micro-optical sectioning tomography for 3D lung analysis<\/strong><\/h2>\n\n\n<p>Researchers at the Chinese Academy of Sciences used advanced micro-optical sectioning tomography (MOST) coupled with whole-lung Nissl-staining to acquire entire mouse-lung structures.<sup>1<\/sup> Fluorescence MOST (fMOST) was also used to track fluorescent model particles within the lung analysis datasets. Thermo Scientific\u2122 Amira\u2122 Software provided image segmentation and 3D reconstruction along with qualitative analysis of lung structure and quantitative analysis of particle deposition in different lung areas.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"460\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-1_1024x460.png\" alt=\"Micro optical sectioning tomography workflow for whole lung analysis\" class=\"wp-image-1754\" title=\"Micro optical sectioning tomography workflow for whole lung analysis\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-1_1024x460.png 1024w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-1_1024x460-300x135.png 300w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-1_1024x460-768x345.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Tomography workflow utilized by Sun et al. Mouse lungs with and without inhaled particles (A and B) were processed for imaging analysis. Resin-embedded mouse lung samples were then imaged with MOST and fMOST; whole lung architecture was obtained by overlapping 80,000 coronal images. Figure reproduced from <a href=\"https:\/\/doi.org\/10.1002\/advs.202003941\" target=\"_blank\" rel=\"noreferrer noopener\">Sun et al<\/a>. under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.en\" target=\"_blank\" rel=\"noreferrer noopener\">CC BY 4.0<\/a>.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"765\" height=\"1024\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-2_1024x1370-765x1024.png\" alt=\"3D rendering of trachea and lung vasculature determined with tomography.\" class=\"wp-image-1755\" title=\"3D rendering of trachea and lung vasculature determined with tomography.\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-2_1024x1370-765x1024.png 765w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-2_1024x1370-224x300.png 224w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-2_1024x1370-768x1028.png 768w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-2_1024x1370.png 1024w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><figcaption class=\"wp-element-caption\">Rendering of trachea and vascular system. (A-G) Images of the lung acquired at different magnification. (H-S) 3D renderings of the mouse lungs along with reconstructions of airways and the vasculature. Figure reproduced from <a href=\"https:\/\/doi.org\/10.1002\/advs.202003941\" target=\"_blank\" rel=\"noreferrer noopener\">Sun et al<\/a>. under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.en\" target=\"_blank\" rel=\"noreferrer noopener\">CC BY 4.0<\/a>.<\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>Whole lung analysis reveals particle distribution<\/strong><\/h2>\n\n\n<p>Volume rendering with Amira Software enabled easy visualization of the whole lung surface. Segmentation tools were used to differentiate various lung structures, including the bronchi, terminal bronchioles, alveoli, arteries, veins, and capillaries. The five lobes of the lung were identified and the number of particles in each lobe was calculated. The Animation Director in Amira Software was also used to edit the recorded frames into movies. The unique flexibility of Amira Software allowed for the visualization of particle distribution within the complex structure of the lungs.<\/p>\n\n\n\n<p>This novel imaging approach could help to optimize DPI drug efficacy through a more complete understanding of particle distribution and how it relates to the architecture of the lung. Ultimately, characterization techniques such as this stand to revolutionize respiratory care and improve the lives of individuals with respiratory conditions.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"1024\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-3_1024x1270-826x1024.png\" alt=\"Particle distribution determined with 3D lung analysis.\" class=\"wp-image-1752\" title=\"Particle distribution determined with 3D lung analysis.\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-3_1024x1270-826x1024.png 826w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-3_1024x1270-242x300.png 242w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-3_1024x1270-768x953.png 768w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Image-3_1024x1270.png 1024w\" sizes=\"auto, (max-width: 826px) 100vw, 826px\" \/><figcaption class=\"wp-element-caption\">Distribution of fluorescent model particles in a mouse lung. The internal trachea of the lung (A) can be overlaid with fluorescent data (B) for a clear visualization of the particle distribution in the lung (C). (D-G) Identification of lung lobes and the extrapulmonary trachea. Almost 50% of the particles were identified in the caudal lobe (3), followed by 27% in the left lobe (1), 15.52% in the extrapulmonary trachea (6), and 5% in the remaining lobes. Figure reproduced from <a href=\"https:\/\/doi.org\/10.1002\/advs.202003941\" target=\"_blank\" rel=\"noreferrer noopener\">Sun et al<\/a>. under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.en\" target=\"_blank\" rel=\"noreferrer noopener\">CC BY 4.0<\/a>.<\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>References<\/strong><\/h2>\n\n\n<p>Sun, X, <em>et al.<\/em><strong>Multiscale Co-reconstruction of Lung Architectures and Inhalable Materials Spatial Distribution.<\/strong><em>Advanced Science<\/em> 8:8 (2021). doi: <a href=\"https:\/\/doi.org\/10.1002\/advs.202003941\" target=\"_blank\" rel=\"noreferrer noopener\">10.1002\/advs.202003941<\/a><\/p>\n\n\n\n<p>Learn more at <a href=\"https:\/\/thermofisher.com\/amira\" target=\"_blank\" rel=\"noreferrer noopener\">thermofisher.com\/amira<\/a><\/p>\n\n\n\n<p>Interested in discussing your image analysis challenges? <a href=\"https:\/\/www.thermofisher.com\/jp\/en\/home\/global\/forms\/industrial\/contact-us-amira-software.html\" target=\"_blank\" rel=\"noreferrer noopener\">Our experts are here to help whenever you&#8217;re ready<\/a>.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Analysis of lung diseases Chronic obstructive pulmonary disease, lower respiratory infections, and lung cancer are among the leading causes of mortality worldwide. A drug delivery methodology called dry powder inhalation (DPI) is being explored as a promising treatment method against pulmonary diseases. For DPI to be considered effective, it is crucial that the drug is<\/p>\n","protected":false},"author":1799,"featured_media":1753,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[322],"tags":[155,188],"division":[],"class_list":{"0":"post-1749","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-amira-software","8":"tag-amira","9":"tag-amira-software","10":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Lung Analysis - Micro Optical Sectioning Tomography - Life in Atomic Resolution<\/title>\n<meta name=\"description\" content=\"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A novel strategy for whole lung analysis with micro-optical sectioning tomography\" \/>\n<meta property=\"og:description\" content=\"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in Atomic Resolution\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-20T16:59:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-03T09:18:30+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Dori Luzbetak\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dori Luzbetak\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/\"},\"author\":{\"name\":\"Dori Luzbetak\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/5944f4a29a4e9da497c5910538045b39\"},\"headline\":\"A novel strategy for whole lung analysis with micro-optical sectioning tomography\",\"datePublished\":\"2025-06-20T16:59:23+00:00\",\"dateModified\":\"2025-09-03T09:18:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/\"},\"wordCount\":549,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/06\\\/Lung-Particle-Detect-Blog-Header_1920x450.png\",\"keywords\":[\"Amira\",\"Amira Software\"],\"articleSection\":[\"Amira Software\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/\",\"name\":\"Lung Analysis - Micro Optical Sectioning Tomography - Life in Atomic Resolution\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/06\\\/Lung-Particle-Detect-Blog-Header_1920x450.png\",\"datePublished\":\"2025-06-20T16:59:23+00:00\",\"dateModified\":\"2025-09-03T09:18:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/5944f4a29a4e9da497c5910538045b39\"},\"description\":\"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/06\\\/Lung-Particle-Detect-Blog-Header_1920x450.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2025\\\/06\\\/Lung-Particle-Detect-Blog-Header_1920x450.png\",\"width\":1920,\"height\":450,\"caption\":\"A novel strategy for whole lung analysis with micro-optical sectioning tomography\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/whole-lung-analysis-with-micro-optical-sectioning-tomography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A novel strategy for whole lung analysis with micro-optical sectioning tomography\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\",\"name\":\"Life in Atomic Resolution\",\"description\":\"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/5944f4a29a4e9da497c5910538045b39\",\"name\":\"Dori Luzbetak\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g\",\"caption\":\"Dori Luzbetak\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/doriluzbetak\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Lung Analysis - Micro Optical Sectioning Tomography - Life in Atomic Resolution","description":"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/","og_locale":"en_US","og_type":"article","og_title":"A novel strategy for whole lung analysis with micro-optical sectioning tomography","og_description":"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.","og_url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/","og_site_name":"Life in Atomic Resolution","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2025-06-20T16:59:23+00:00","article_modified_time":"2025-09-03T09:18:30+00:00","og_image":[{"width":1920,"height":450,"url":"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","type":"image\/png"}],"author":"Dori Luzbetak","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Dori Luzbetak","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/"},"author":{"name":"Dori Luzbetak","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/5944f4a29a4e9da497c5910538045b39"},"headline":"A novel strategy for whole lung analysis with micro-optical sectioning tomography","datePublished":"2025-06-20T16:59:23+00:00","dateModified":"2025-09-03T09:18:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/"},"wordCount":549,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","keywords":["Amira","Amira Software"],"articleSection":["Amira Software"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/","url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/","name":"Lung Analysis - Micro Optical Sectioning Tomography - Life in Atomic Resolution","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","datePublished":"2025-06-20T16:59:23+00:00","dateModified":"2025-09-03T09:18:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/5944f4a29a4e9da497c5910538045b39"},"description":"Whole lung analysis with micro optical sectioning tomography provides insights into pulmonary diseases through 3D lung imaging analysis.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","width":1920,"height":450,"caption":"A novel strategy for whole lung analysis with micro-optical sectioning tomography"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/whole-lung-analysis-with-micro-optical-sectioning-tomography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/"},{"@type":"ListItem","position":2,"name":"A novel strategy for whole lung analysis with micro-optical sectioning tomography"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/","name":"Life in Atomic Resolution","description":"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/5944f4a29a4e9da497c5910538045b39","name":"Dori Luzbetak","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/99327b5b23d464e7f417c6cd39191ca7b23ba091c1e029cdecaf206200bde5f6?s=96&d=mm&r=g","caption":"Dori Luzbetak"},"url":"https:\/\/admin.acceleratingscience.com\/author\/doriluzbetak\/"}]}},"taxonomy_info":{"category":[{"value":322,"label":"Amira Software"}],"post_tag":[{"value":155,"label":"Amira"},{"value":188,"label":"Amira Software"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450-1024x240.png",760,178,true],"author_info":{"display_name":"Dori Luzbetak","author_link":"https:\/\/admin.acceleratingscience.com\/author\/doriluzbetak\/"},"comment_info":0,"category_info":[{"term_id":322,"name":"Amira Software","slug":"amira-software","term_group":0,"term_taxonomy_id":322,"taxonomy":"category","description":"","parent":24,"count":10,"filter":"raw","meta":[],"cat_ID":322,"category_count":10,"category_description":"","cat_name":"Amira Software","category_nicename":"amira-software","category_parent":24}],"tag_info":[{"term_id":155,"name":"Amira","slug":"amira","term_group":0,"term_taxonomy_id":155,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]},{"term_id":188,"name":"Amira Software","slug":"amira-software","term_group":0,"term_taxonomy_id":188,"taxonomy":"post_tag","description":"","parent":0,"count":13,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":2071,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/facilitating-soft-tissue-analysis-unraveling-complex-microct-imaging-data-with-amira-software\/","url_meta":{"origin":1749,"position":0},"title":"Facilitating Soft Tissue Analysis \u2013 Unraveling Complex MicroCT Imaging Data with Amira Software","author":"Vinay S","date":"August 27, 2026","format":false,"excerpt":"Key takeaways Micro-computed X-ray tomography (microCT) can be used for high-resolution, 3D visualization of a range of biological samples, including soft tissues, but transforming this data into scientific insights requires the processing of increasingly large, complex datasets. Thermo Scientific Amira Software is a powerful data processing tool that can simplify\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Facilitating Soft Tissue Analysis \u2013 Unraveling Complex MicroCT Imaging Data with Amira Software","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1953,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/3d-tissue-histology-light-sheet-microscopy-for-nondestructive-microglia-structure-analysis\/","url_meta":{"origin":1749,"position":1},"title":"3D Tissue Histology with Light-Sheet Microscopy Enables Nondestructive Analysis of Microglia","author":"Vinay S","date":"January 21, 2026","format":false,"excerpt":"3D tissue analysis offers critical benefits for neuroscience research The imaging and analysis of tissues is vital across a number of biological fields, particularly neuroscience, where the accurate characterization of neural tissue plays an important role in our understanding of the nervous system. Historically, these samples were imaged as thin\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"3D Tissue Histology with Light-Sheet Microscopy Enables Nondestructive Analysis of Microglia","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/01\/neuroscience-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2016,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/how-artificial-intelligence-ai-improves-image-analysis-workflows-in-life-sciences\/","url_meta":{"origin":1749,"position":2},"title":"How artificial intelligence (AI) improves image analysis workflows in life sciences","author":"Vinay S","date":"June 2, 2026","format":false,"excerpt":"Image acquisition is not the end of the story\u2014it is the starting point. Once images are captured, researchers typically move into preprocessing to improve quality, then they perform visualization, segmentation, and quantitative analysis to extract meaningful measurements. The goal is simple: turn images into understanding. In practice, however, image analysis\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"How artificial intelligence (AI) improves image analysis workflows in life sciences","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1935,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/fragment-based-drug-discovery-of-drug-targets-membrane-proteins-with-cryo-em\/","url_meta":{"origin":1749,"position":3},"title":"Fragment based drug discovery meets challenging drug targets with high-throughput cryo-EM\u00a0","author":"Swarnim Rawat","date":"December 12, 2025","format":false,"excerpt":"Benefits of FBDD in the search for novel therapeutics\u00a0 Fragment-based drug discovery (FBDD) is a method that screens a large quantity of protein fragments for their potential as small molecule therapeutics. This approach was previously hampered by the slow throughput of crystallization for the characterization of potential leads. The increasing\u2026","rel":"","context":"In &quot;Cryo EM Drug Discovery&quot;","block_context":{"text":"Cryo EM Drug Discovery","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-drug-discovery\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1854,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-100-kv-high-resolution-cryo-em-single-particle-analysis\/","url_meta":{"origin":1749,"position":4},"title":"Advances in high-resolution cryo-EM at 100 kV","author":"Swarnim Rawat","date":"February 5, 2026","format":false,"excerpt":"100 kV cryo-TEM enables high-resolution single particle analysis Within the past decade, cryo-electron microscopy (cryo-EM) techniques have revolutionized structural biology by enabling the visualization of challenging molecular and sub-cellular structures in their near-native states at high resolution. These valuable observations have, until recently, been relegated to advanced 300 kV instruments\u2026","rel":"","context":"In &quot;Cryo-Electron Microscopy (Cryo-EM)&quot;","block_context":{"text":"Cryo-Electron Microscopy (Cryo-EM)","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/"},"img":{"alt_text":"Advances in high-resolution cryo-EM at 100 kV","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2117,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-cryo-electron-tomography-expand-the-capabilities-of-quantitative-cell-biology\/","url_meta":{"origin":1749,"position":5},"title":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology","author":"Vinay S","date":"September 29, 2026","format":false,"excerpt":"Key takeaways Cryo-electron tomography has largely been seen as a qualitative method because cryo-ET data segmentation has been a highly intensive, manual process. Recent advances in deep-learning-based segmentation have expanded the capabilities of cryo-electron tomography, supporting quantitative analysis of cellular structures. A recent webinar by Professor Danielle Grotjahn highlights how\u2026","rel":"","context":"In &quot;Cryo EM Techniques&quot;","block_context":{"text":"Cryo EM Techniques","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-techniques\/"},"img":{"alt_text":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/06\/Lung-Particle-Detect-Blog-Header_1920x450.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/1749","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/users\/1799"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/comments?post=1749"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/1749\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media\/1753"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media?parent=1749"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/categories?post=1749"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/tags?post=1749"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/division?post=1749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}