{"id":2172,"date":"2026-10-19T16:36:48","date_gmt":"2026-10-19T16:36:48","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/?p=2172"},"modified":"2026-10-19T16:36:51","modified_gmt":"2026-10-19T16:36:51","slug":"what-is-subtomogram-averaging","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","title":{"rendered":"What is Subtomogram Averaging?"},"content":{"rendered":"<h2 style=\"font-size: 100%\"><strong>Turning crowded cryo-ET data into structural insight with subtomogram averaging<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/electron-microscopy\/life-sciences\/cryo-tomography.html\">Cryo-electron tomography (cryo-ET)<\/a> is capable of capturing detailed, three-dimensional views of vitrified biological samples, supporting a broad range of life sciences research. Subtomogram averaging helps refine that crowded data for clearer structural insight by finding repeated particles, extracting them as small 3D volumes, and then aligning and averaging them together so that the shared signals becomes easier to see (Figure 1).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Subtomogram averaging is especially useful for recurring cellular assemblies such as ribosomes, proteasomes, microtubules, and other macromolecular structures, such as nuclear pore complexes, all of which may appear many times in a single dataset. By grouping those copies, aligning them to a common reference frame, and averaging them, subtomogram averaging is able to strengthen shared structural features while reducing random noise (Figure 1).<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"672\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1-672x1024.png\" alt=\"Schematic overview of a subtomogram averaging workflow in cryo-electron tomography (cryo-ET), illustrating the identification, extraction, alignment, and averaging of repeating molecular structures from tomographic data to generate a high-resolution 3D reconstruction.\" class=\"wp-image-2175\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1-672x1024.png 672w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1-197x300.png 197w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1-768x1171.png 768w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1-1008x1536.png 1008w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure1-1024x1561-1.png 1024w\" sizes=\"auto, (max-width: 672px) 100vw, 672px\" \/><figcaption class=\"wp-element-caption\"><em>Figure 1. Overview of a typical subtomogram averaging workflow, showing the processing of repeat structures in a cryo-ET dataset. Figure reproduced under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\">CC BY 4.0<\/a> from <a href=\"https:\/\/doi.org\/10.1042\/BCJ20200715\">Pyle and Zanetti (2021)<\/a>.<\/em><\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>How does a tomogram become an averaged structure?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">Subtomogram averaging begins with the identification of particles and structures of interest within the crowded cellular tomograms. This can be done with segmentation, which can help identify components such as membranes or microtubules, as well as 3D template matching, which can find features that match a selected reference structure. During the template matching process, the reference is low-pass filtered and rescaled to the pixel size, then searched exhaustively across positions and orientations to generate a score map. Peaks in that map point to candidate particle positions and orientations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once particles are located using either method, they are separated out as a subtomogram. Those subtomograms are then rotated and translated into the same orientation and averaged. If these particles are the same structure, common features become stronger while noise is reduced.<\/p>\n\n\n<h2 style=\"font-size: 100%\"><strong>How can template matching help answer spatial questions?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">Template matching is useful not only as a part of subtomogram averaging but also as a general way to localize a structure within a tomogram. It makes it possible to ask where a particle is located and how it is oriented, even when the target is sparse or when there is not enough data to run a full subtomogram averaging pipeline.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"993\" height=\"1024\" src=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure2-1024x1056-1-993x1024.png\" alt=\"Schematic illustration of template matching for visual proteomics, showing (A) a cryo-electron tomogram, (B) cross-correlation with a library of reference structures to identify molecular targets, and (C) 3D localization maps generated from z-score data to visualize protein distributions and spatial interactions.\" class=\"wp-image-2176\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure2-1024x1056-1-993x1024.png 993w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure2-1024x1056-1-291x300.png 291w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure2-1024x1056-1-768x792.png 768w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure2-1024x1056-1.png 1024w\" sizes=\"auto, (max-width: 993px) 100vw, 993px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 2. <\/strong>Template matching for visual proteomics. A tomogram (A) is cross-correlated independently with each template in a library of reference structures (B) to identify points with high constrained-cross-correlation values. From the z-score maps, 3D localization maps (C) are generated for visualization <a href=\"https:\/\/www.nature.com\/articles\/s41467-024-47839-8#ref-CR65\"><\/a>and analysis of spatial interactions. Figure reproduced under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\">CC BY 4.0<\/a> from <a href=\"https:\/\/doi.org\/10.1038\/s41467-024-47839-8\">Cruz-Le\u00f3n et al. (2024).<\/a><\/em><\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>What is the importance of particle orientation in subtomogram averaging?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">Cryo-ET reconstruction is limited by the so-called missing wedge: the range of angles at which information is sampled from the specimen is limited, meaning that some structural information is not collected. It can result in structures that are less well resolved or visible in certain directions. As each particle is usually oriented differently within the sample, their orientation can play an important role in these variations and produce a more complex result. The effect of the missing wedge is illustrated in Figure 3A, where progressively reducing the tilt range leads to increasing reconstruction artifacts and loss of horizontally oriented features; Figure 3B shows this effect in a biological sample.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"737\" src=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure3-1024x737-1.png\" alt=\"Illustration of the missing-wedge effect in cryo-electron tomography (cryo-ET), showing (A) simulated reconstructions with decreasing tilt ranges from \u00b190\u00b0 to \u00b145\u00b0, resulting in increased artifacts and loss of horizontally oriented features, and (B) an experimental reconstruction of a frozen E. coli cell demonstrating reduced visibility of cellular structures due to limited angular sampling.\" class=\"wp-image-2177\" srcset=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure3-1024x737-1.png 1024w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure3-1024x737-1-300x216.png 300w, https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/BLG-16219854-Cryo-EM-Series-2-Blog-Figure3-1024x737-1-768x553.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em><strong>Figure 3.<\/strong> The missing-wedge effect in cryo-ET reconstruction. (A) Simulation showing the effect of progressively reducing the angular range used for reconstruction from \u00b190\u00b0 to \u00b145\u00b0. As the tilt range decreases, reconstruction artifacts increase and horizontally oriented features are increasingly lost. (B) Experimental example from a frozen E. coli cell showing how limited angular sampling can affect the visibility of cellular structures. Reproduced and adapted from <a href=\"https:\/\/doi.org\/10.1016\/j.ultramic.2013.10.016\">Palmer and L\u00f6we (2014)<\/a> under <a href=\"https:\/\/creativecommons.org\/licenses\/by\/3.0\/\">CC BY 3.0<\/a>.<\/em><\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>What can subtomogram averaging reveal that a single tomogram may not?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">The value of subtomogram averaging is not just sharper density, it is the ability to connect structure with context. Once particles are averaged, the result can be placed back into the original tomogram to probe spatial questions: Where is the complex located? How is it oriented? How does it sit relative to nearby cellular structures? Template matching can also be used when these questions do not require a full subtomogram averaging pipeline.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For virology, cell and membrane biology, as well as other <em>in situ<\/em> applications, this contextualization is especially valuable. These approaches can help reveal recurring molecular assemblies inside cells, show how they are positioned relative to one another, and support a more spatial view of biology. This can also serve as a useful route into visual proteomics, where molecular machines are studied in 3D rather than as isolated particles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Recent publications show the practical benefit of subtomogram averaging for <em>in situ <\/em>studies<em>, <\/em>helping to resolve structures across viral replication organelles, mitochondrial machinery, and membrane-associated coat assemblies. This includes a SARS-CoV-2 double-membrane vesicle pore at 4.2 \u00c5 (<a href=\"https:\/\/doi.org\/10.1038\/s41586-024-07817-y\">Huang <em>et al. <\/em>(2024)<\/a>), mitochondrial ATP synthase in whole <em>Polytomella<\/em> cells at 4.2 \u00c5 (<a href=\"https:\/\/doi.org\/10.1126\/science.adp4640\">Dietrich et al. (2024)<\/a>), and COPII coat assemblies on cargo-containing membranes at 4.1 \u00c5 (<a href=\"https:\/\/doi.org\/10.1038\/s41594-024-01413-4\">Pyle <em>et al.<\/em> (2024)<\/a>).<\/p>\n\n\n<h2 style=\"font-size: 100%\"><strong>How can you optimize a subtomogram averaging workflow?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">Subtomogram averaging depends on the quality of the full cryo-ET workflow, and it works best when sample preparation, acquisition, reconstruction, particle detection, and alignment are all matched to the question being asked.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To start, thick samples may need thinning before imaging, using methods such as cryo-focused ion beam milling or cryo-ultramicrotomy. The alignment of the tilt series after data collection is also critical. This can be performed manually or automatically using either fiducial markers or marker-free approaches such as patch tracking or machine learning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The reconstruction method is no less important. Weighted back projection is commonly used when downstream averaging is the goal, while iterative methods such as simultaneous iterative reconstruction technique (SIRT) and simultaneous algebraic reconstruction technique (SART) can produce sharper, higher-contrast volumes that are useful for visualization, annotation, and segmentation. Denoising can also be used to make particle finding easier, but weighted back-projection is generally preferred because it preserves the original signal more directly.<\/p>\n\n\n<h2 style=\"font-size: 100%\"><strong>When is subtomogram averaging the right next step?<\/strong><\/h2>\n\n\n<p class=\"wp-block-paragraph\">Subtomogram averaging is most useful when a sample contains repeated copies of the same structure, and those copies appear in enough orientations to be well aligned and averaged. It has particular value when the biological question is not just \u201cWhat is here?\u201d but also \u201cHow is it organized?\u201d and \u201cWhat does that organization suggest about function?\u201d With subtomogram averaging, crowded cryo-ET data can turn into a clear view of molecular structure in its cellular setting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/uk\/en\/home\/electron-microscopy\/life-sciences\/cryo-tomography.html\"><strong>Learn more about cryo-electron tomography and subtomogram averaging &gt;&gt;<\/strong><\/a><strong><\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator aligncenter has-alpha-channel-opacity is-style-wide\" \/>\n\n\n\n<p class=\"wp-block-paragraph\">Header image shows Chikungunya virus assembly and budding, visualized <em>in situ <\/em>using subtomogram averaging. Recreated from <a href=\"https:\/\/www.emdataresource.org\/EMD-26448\">EMD-26448<\/a>. Original study by <a href=\"https:\/\/doi.org\/10.1038\/s41564-022-01164-2\">Chmielewski <em>et al.<\/em> (2022)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Turning crowded cryo-ET data into structural insight with subtomogram averaging Cryo-electron tomography (cryo-ET) is capable of capturing detailed, three-dimensional views of vitrified biological samples, supporting a broad range of life sciences research. Subtomogram averaging helps refine that crowded data for clearer structural insight by finding repeated particles, extracting them as small 3D volumes, and then<\/p>\n","protected":false},"author":1809,"featured_media":2174,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[324,334,330,24,128],"tags":[],"division":[360],"class_list":["post-2172","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cancer-research","category-cell-biology","category-cryo-em-techniques","category-cryo-electron-microscopy-cryo-em","category-cryo-electron-tomography","division-msd","entry"],"_selected_authors":[1389,1292],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What is Subtomogram Averaging? - Cryo ET - Cryo Electron Tomography - Thermo Fisher Scientific<\/title>\n<meta name=\"description\" content=\"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is Subtomogram Averaging?\" \/>\n<meta property=\"og:description\" content=\"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in Atomic Resolution\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-19T16:36:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-19T16:36:51+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Swarnim Rawat\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Swarnim Rawat\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/\"},\"author\":{\"name\":\"Swarnim Rawat\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/69f922bec6e68102286c598737517b9c\"},\"headline\":\"What is Subtomogram Averaging?\",\"datePublished\":\"2026-10-19T16:36:48+00:00\",\"dateModified\":\"2026-10-19T16:36:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/\"},\"wordCount\":1106,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2026\\\/10\\\/social.png\",\"articleSection\":[\"Cancer Research\",\"Cell Biology\",\"Cryo EM Techniques\",\"Cryo-Electron Microscopy (Cryo-EM)\",\"Cryo-Electron Tomography\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/\",\"name\":\"What is Subtomogram Averaging? - Cryo ET - Cryo Electron Tomography - Thermo Fisher Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2026\\\/10\\\/social.png\",\"datePublished\":\"2026-10-19T16:36:48+00:00\",\"dateModified\":\"2026-10-19T16:36:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/69f922bec6e68102286c598737517b9c\"},\"description\":\"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2026\\\/10\\\/social.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2026\\\/10\\\/social.png\",\"width\":750,\"height\":450,\"caption\":\"Social Cryo EM\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/atomic-resolution\\\/what-is-subtomogram-averaging\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is Subtomogram Averaging?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\",\"name\":\"Life in Atomic Resolution\",\"description\":\"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/69f922bec6e68102286c598737517b9c\",\"name\":\"Swarnim Rawat\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g\",\"caption\":\"Swarnim Rawat\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/swarnim-rawatthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What is Subtomogram Averaging? - Cryo ET - Cryo Electron Tomography - Thermo Fisher Scientific","description":"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","og_locale":"en_US","og_type":"article","og_title":"What is Subtomogram Averaging?","og_description":"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.","og_url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","og_site_name":"Life in Atomic Resolution","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-10-19T16:36:48+00:00","article_modified_time":"2026-10-19T16:36:51+00:00","og_image":[{"width":750,"height":450,"url":"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","type":"image\/png"}],"author":"Swarnim Rawat","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Swarnim Rawat","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/"},"author":{"name":"Swarnim Rawat","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/69f922bec6e68102286c598737517b9c"},"headline":"What is Subtomogram Averaging?","datePublished":"2026-10-19T16:36:48+00:00","dateModified":"2026-10-19T16:36:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/"},"wordCount":1106,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","articleSection":["Cancer Research","Cell Biology","Cryo EM Techniques","Cryo-Electron Microscopy (Cryo-EM)","Cryo-Electron Tomography"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","name":"What is Subtomogram Averaging? - Cryo ET - Cryo Electron Tomography - Thermo Fisher Scientific","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","datePublished":"2026-10-19T16:36:48+00:00","dateModified":"2026-10-19T16:36:51+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/69f922bec6e68102286c598737517b9c"},"description":"What is subtomogram averaging? Learn how this cryo EM data analysis method enhances cryo-electron tomography to reveal cellular context.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","width":750,"height":450,"caption":"Social Cryo EM"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/"},{"@type":"ListItem","position":2,"name":"What is Subtomogram Averaging?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/","name":"Life in Atomic Resolution","description":"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/69f922bec6e68102286c598737517b9c","name":"Swarnim Rawat","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f02bed90065ce2b327ace32b6aa4a9252da3c8b1091d0ca100c642490c42ec8f?s=96&d=mm&r=g","caption":"Swarnim Rawat"},"url":"https:\/\/admin.acceleratingscience.com\/author\/swarnim-rawatthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":324,"label":"Cancer Research"},{"value":334,"label":"Cell Biology"},{"value":330,"label":"Cryo EM Techniques"},{"value":24,"label":"Cryo-Electron Microscopy (Cryo-EM)"},{"value":128,"label":"Cryo-Electron Tomography"}],"division":[{"value":360,"label":"MSD"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png",750,450,false],"author_info":{"display_name":"Swarnim Rawat","author_link":"https:\/\/admin.acceleratingscience.com\/author\/swarnim-rawatthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":324,"name":"Cancer Research","slug":"cancer-research","term_group":0,"term_taxonomy_id":324,"taxonomy":"category","description":"","parent":322,"count":3,"filter":"raw","meta":[],"cat_ID":324,"category_count":3,"category_description":"","cat_name":"Cancer Research","category_nicename":"cancer-research","category_parent":322},{"term_id":334,"name":"Cell Biology","slug":"cell-biology","term_group":0,"term_taxonomy_id":334,"taxonomy":"category","description":"","parent":322,"count":5,"filter":"raw","meta":[],"cat_ID":334,"category_count":5,"category_description":"","cat_name":"Cell Biology","category_nicename":"cell-biology","category_parent":322},{"term_id":330,"name":"Cryo EM Techniques","slug":"cryo-em-techniques","term_group":0,"term_taxonomy_id":330,"taxonomy":"category","description":"","parent":24,"count":5,"filter":"raw","meta":[],"cat_ID":330,"category_count":5,"category_description":"","cat_name":"Cryo EM Techniques","category_nicename":"cryo-em-techniques","category_parent":24},{"term_id":24,"name":"Cryo-Electron Microscopy (Cryo-EM)","slug":"cryo-electron-microscopy-cryo-em","term_group":0,"term_taxonomy_id":24,"taxonomy":"category","description":"","parent":0,"count":79,"filter":"raw","meta":[],"cat_ID":24,"category_count":79,"category_description":"","cat_name":"Cryo-Electron Microscopy (Cryo-EM)","category_nicename":"cryo-electron-microscopy-cryo-em","category_parent":0},{"term_id":128,"name":"Cryo-Electron Tomography","slug":"cryo-electron-tomography","term_group":0,"term_taxonomy_id":128,"taxonomy":"category","description":"","parent":24,"count":16,"filter":"raw","meta":[],"cat_ID":128,"category_count":16,"category_description":"","cat_name":"Cryo-Electron Tomography","category_nicename":"cryo-electron-tomography","category_parent":24}],"tag_info":false,"jetpack-related-posts":[{"id":2117,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-cryo-electron-tomography-expand-the-capabilities-of-quantitative-cell-biology\/","url_meta":{"origin":2172,"position":0},"title":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology","author":"Vinay S","date":"September 29, 2026","format":false,"excerpt":"Key takeaways Cryo-electron tomography has largely been seen as a qualitative method because cryo-ET data segmentation has been a highly intensive, manual process. Recent advances in deep-learning-based segmentation have expanded the capabilities of cryo-electron tomography, supporting quantitative analysis of cellular structures. A recent webinar by Professor Danielle Grotjahn highlights how\u2026","rel":"","context":"In &quot;Cryo EM Techniques&quot;","block_context":{"text":"Cryo EM Techniques","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-techniques\/"},"img":{"alt_text":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1854,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-100-kv-high-resolution-cryo-em-single-particle-analysis\/","url_meta":{"origin":2172,"position":1},"title":"Advances in high-resolution cryo-EM at 100 kV","author":"Swarnim Rawat","date":"February 5, 2026","format":false,"excerpt":"100 kV cryo-TEM enables high-resolution single particle analysis Within the past decade, cryo-electron microscopy (cryo-EM) techniques have revolutionized structural biology by enabling the visualization of challenging molecular and sub-cellular structures in their near-native states at high resolution. These valuable observations have, until recently, been relegated to advanced 300 kV instruments\u2026","rel":"","context":"In &quot;Cryo-Electron Microscopy (Cryo-EM)&quot;","block_context":{"text":"Cryo-Electron Microscopy (Cryo-EM)","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/"},"img":{"alt_text":"Advances in high-resolution cryo-EM at 100 kV","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1935,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/fragment-based-drug-discovery-of-drug-targets-membrane-proteins-with-cryo-em\/","url_meta":{"origin":2172,"position":2},"title":"Fragment based drug discovery meets challenging drug targets with high-throughput cryo-EM\u00a0","author":"Swarnim Rawat","date":"December 12, 2025","format":false,"excerpt":"Benefits of FBDD in the search for novel therapeutics\u00a0 Fragment-based drug discovery (FBDD) is a method that screens a large quantity of protein fragments for their potential as small molecule therapeutics. This approach was previously hampered by the slow throughput of crystallization for the characterization of potential leads. The increasing\u2026","rel":"","context":"In &quot;Cryo EM Drug Discovery&quot;","block_context":{"text":"Cryo EM Drug Discovery","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-drug-discovery\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2143,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/microscopy-image-analysis-with-amira-software-ai-in-cell-biology\/","url_meta":{"origin":2172,"position":3},"title":"Four ways AI is making microscopy image analysis easier for cell biologists","author":"Alejandra Sanchez-Erostegui","date":"October 14, 2026","format":false,"excerpt":"Key takeaways Modern microscopes are capable of generating large volumes of high-resolution data, which is highly valuable for cell biology research, but also makes it increasingly more laborious and difficult to extract meaningful scientific information from the whole dataset.\u00a0 Artificial intelligence is well positioned to support this work by streamlining\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Four ways AI is making microscopy image analysis easier for cell biologists.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2016,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/how-artificial-intelligence-ai-improves-image-analysis-workflows-in-life-sciences\/","url_meta":{"origin":2172,"position":4},"title":"How artificial intelligence (AI) improves image analysis workflows in life sciences","author":"Vinay S","date":"June 2, 2026","format":false,"excerpt":"Image acquisition is not the end of the story\u2014it is the starting point. Once images are captured, researchers typically move into preprocessing to improve quality, then they perform visualization, segmentation, and quantitative analysis to extract meaningful measurements. The goal is simple: turn images into understanding. In practice, however, image analysis\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"How artificial intelligence (AI) improves image analysis workflows in life sciences","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2071,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/facilitating-soft-tissue-analysis-unraveling-complex-microct-imaging-data-with-amira-software\/","url_meta":{"origin":2172,"position":5},"title":"Facilitating Soft Tissue Analysis \u2013 Unraveling Complex MicroCT Imaging Data with Amira Software","author":"Vinay S","date":"August 27, 2026","format":false,"excerpt":"Key takeaways Micro-computed X-ray tomography (microCT) can be used for high-resolution, 3D visualization of a range of biological samples, including soft tissues, but transforming this data into scientific insights requires the processing of increasingly large, complex datasets. Thermo Scientific Amira Software is a powerful data processing tool that can simplify\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Facilitating Soft Tissue Analysis \u2013 Unraveling Complex MicroCT Imaging Data with Amira Software","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/08\/blog-soft-tissue-micro-ct-research-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/2172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/users\/1809"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/comments?post=2172"}],"version-history":[{"count":4,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/2172\/revisions"}],"predecessor-version":[{"id":2181,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/2172\/revisions\/2181"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media\/2174"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media?parent=2172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/categories?post=2172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/tags?post=2172"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/division?post=2172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}