{"id":524,"date":"2020-10-28T19:16:31","date_gmt":"2020-10-28T19:16:31","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/2020\/10\/28\/breakthrough-advances-in-atomic-resolution-cryo-em\/"},"modified":"2020-10-28T19:16:31","modified_gmt":"2020-10-28T19:16:31","slug":"breakthrough-advances-in-atomic-resolution-cryo-em","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/","title":{"rendered":"Breakthrough Advances in Atomic Resolution Cryo-EM"},"content":{"rendered":"<p>Earlier this year, we unveiled new imaging filters that make it possible to view proteins at true atomic resolution. This technology has already led to stunning breakthroughs in cryo-electron microscopy (cryo-EM) research.<\/p>\n<h2 style=\"color:white;font-size:50%\">Latest advances in atomic resolution cryo electron microscopy<\/h2>\n<p>Using the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/products\/accessories-em\/selectris.html\">Selectris X Imaging Filter<\/a> in combination with a Krios Cryo-Transmission Electron Microscope, my colleagues collaborated with researchers from the <a href=\"https:\/\/www2.mrc-lmb.cam.ac.uk\/\">Medical Research Council Laboratory of Molecular Biology<\/a> in Cambridge, UK to <a href=\"https:\/\/phys.org\/news\/2020-10-scientists-resolution-visualize-individual-atoms.html\">obtain<\/a> a 1.2 \u00e5ngstr\u00f6m resolution structure of the iron-storing protein apoferritin. They also achieved a 1.7 \u00e5ngstr\u00f6m resolution of the GABA Type A receptor-associated protein, with an even sharper resolution in key parts of the protein. These record-breaking resolution results, which were <a href=\"https:\/\/www.nature.com\/articles\/d41586-020-02924-y\">published in Nature on Oct. 21,<\/a> are just one example of the breakthrough discoveries speeding the path to disease understanding and treatment.<\/p>\n<p>As cryo-EM research breaks <a href=\"https:\/\/www.sciencemag.org\/news\/2020\/10\/cryo-electron-microscopy-breaks-atomic-resolution-barrier-last\">the atomic resolution barrier<\/a> and launches a second resolution revolution, biologists are achieving a wide range of critical breakthroughs. New levels of automation in recent technologies facilitate sample preparation and lamella creation, making it easier to see proteins close to their native state. Our Nov. 5 livestream event, <a href=\"https:\/\/thermofisher.com\/atomicresolution\"><em>Atomic Resolution Cryo-EM: There\u2019s More!<\/em> <\/a>will show how these advancements accelerate the path to drug discovery.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1403 aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg\" alt=\"Atomic resolution apoferritin structure\" title=\"Atomic resolution apoferritin structure\" width=\"1474\" height=\"650\" \/><\/p>\n<p style=\"text-align: center\"><em>Using a Selectris X filter, researchers at the Medical Research Council Laboratory of Molecular Biology obtained a 1.2 \u00e5ngstr\u00f6m resolution structure of the protein apoferritin.<\/em> (Image courtesy of Sjors Scheres, MRC-LMB, Cambridge and Abhay Kotecha, Thermo Fisher Scientific)<\/p>\n<h2 style=\"color:white;font-size:50%\">Cryo electron microscopy instrumentation webinar<\/h2>\n<p>Please join our livestream where our team will discuss some of the relentless innovation over the past year that\u2019s led to this resolution milestone. We\u2019ll showcase recent record-breaking research, including 200 kV results from the Thermo Scientific Glacios Cryo-TEM, showing how scientists are uncovering protein structures at the atomic level and changing the game for drug discovery. We are excited to answer your questions and look forward to an engaging session.<\/p>\n<p><em>Steve Reyntjens<\/em><em> is a Director of Product Marketing of Life Sciences Electron Microscopy <\/em><em>at Thermo Fisher Scientific.<\/em><\/p>\n<p><em>\u00a0<\/em>\/\/\/<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/subscribe-to-accelerating-microscopy\/\">Subscribe now<\/a> to receive Accelerating Microscopy updates straight to your inbox.<\/p>\n<p>Speak with an expert: <a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/speak-with-an-expert\/\">https:\/\/www.thermofisher.com\/blog\/microscopy\/speak-with-an-expert\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Earlier this year, we unveiled new imaging filters that make it possible to view proteins at true atomic resolution. This technology has already led to stunning breakthroughs in cryo-electron microscopy (cryo-EM) research. Latest advances in atomic resolution cryo electron microscopy Using the Selectris X Imaging Filter in combination with a Krios Cryo-Transmission Electron Microscope, my<\/p>\n","protected":false},"author":954,"featured_media":525,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[33],"tags":[],"division":[],"class_list":["post-524","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Advances in Atomic Resolution Cryo EM - Life in Atomic Resolution<\/title>\n<meta name=\"description\" content=\"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Breakthrough Advances in Atomic Resolution Cryo-EM\" \/>\n<meta property=\"og:description\" content=\"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in Atomic Resolution\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-10-28T19:16:31+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1474\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steve Reyntjens\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Steve Reyntjens\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/\"},\"author\":{\"name\":\"Steve Reyntjens\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/9b8ad51824f42ee7114a831fb1a61c88\"},\"headline\":\"Breakthrough Advances in Atomic Resolution Cryo-EM\",\"datePublished\":\"2020-10-28T19:16:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/\"},\"wordCount\":363,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/Selectris.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/\",\"name\":\"Advances in Atomic Resolution Cryo EM - Life in Atomic Resolution\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/Selectris.jpg\",\"datePublished\":\"2020-10-28T19:16:31+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/9b8ad51824f42ee7114a831fb1a61c88\"},\"description\":\"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/Selectris.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/04\\\/Selectris.jpg\",\"width\":1474,\"height\":650},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/breakthrough-advances-in-atomic-resolution-cryo-em\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Breakthrough Advances in Atomic Resolution Cryo-EM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\",\"name\":\"Life in Atomic Resolution\",\"description\":\"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/9b8ad51824f42ee7114a831fb1a61c88\",\"name\":\"Steve Reyntjens\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g\",\"caption\":\"Steve Reyntjens\"},\"sameAs\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/microscopy\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/stevereyntjens\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Advances in Atomic Resolution Cryo EM - Life in Atomic Resolution","description":"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/","og_locale":"en_US","og_type":"article","og_title":"Breakthrough Advances in Atomic Resolution Cryo-EM","og_description":"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique","og_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/","og_site_name":"Life in Atomic Resolution","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-10-28T19:16:31+00:00","og_image":[{"width":1474,"height":650,"url":"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","type":"image\/jpeg"}],"author":"Steve Reyntjens","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Steve Reyntjens","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#article","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/"},"author":{"name":"Steve Reyntjens","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/9b8ad51824f42ee7114a831fb1a61c88"},"headline":"Breakthrough Advances in Atomic Resolution Cryo-EM","datePublished":"2020-10-28T19:16:31+00:00","mainEntityOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/"},"wordCount":363,"commentCount":0,"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/","name":"Advances in Atomic Resolution Cryo EM - Life in Atomic Resolution","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website"},"primaryImageOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#primaryimage"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","datePublished":"2020-10-28T19:16:31+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/9b8ad51824f42ee7114a831fb1a61c88"},"description":"Atomic resolution cryo EM promises to bring critical breakthroughs in biological research. See how our Selectris Imaging Filter enables this novel technique","breadcrumb":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","width":1474,"height":650},{"@type":"BreadcrumbList","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/breakthrough-advances-in-atomic-resolution-cryo-em\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/"},{"@type":"ListItem","position":2,"name":"Breakthrough Advances in Atomic Resolution Cryo-EM"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/","name":"Life in Atomic Resolution","description":"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/9b8ad51824f42ee7114a831fb1a61c88","name":"Steve Reyntjens","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/259106db565e7f5a9376472a0f4a21e194873d888dd8d678919e3e1a0204b7df?s=96&d=mm&r=g","caption":"Steve Reyntjens"},"sameAs":["https:\/\/admin.acceleratingscience.com\/microscopy"],"url":"https:\/\/admin.acceleratingscience.com\/author\/stevereyntjens\/"}]}},"taxonomy_info":{"category":[{"value":33,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris-1024x452.jpg",760,335,true],"author_info":{"display_name":"Steve Reyntjens","author_link":"https:\/\/admin.acceleratingscience.com\/author\/stevereyntjens\/"},"comment_info":0,"category_info":[{"term_id":33,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":33,"taxonomy":"category","description":"","parent":0,"count":59,"filter":"raw","meta":[],"cat_ID":33,"category_count":59,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":1854,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-100-kv-high-resolution-cryo-em-single-particle-analysis\/","url_meta":{"origin":524,"position":0},"title":"Advances in high-resolution cryo-EM at 100 kV","author":"Swarnim Rawat","date":"February 5, 2026","format":false,"excerpt":"100 kV cryo-TEM enables high-resolution single particle analysis Within the past decade, cryo-electron microscopy (cryo-EM) techniques have revolutionized structural biology by enabling the visualization of challenging molecular and sub-cellular structures in their near-native states at high resolution. These valuable observations have, until recently, been relegated to advanced 300 kV instruments\u2026","rel":"","context":"In &quot;Cryo-Electron Microscopy (Cryo-EM)&quot;","block_context":{"text":"Cryo-Electron Microscopy (Cryo-EM)","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/"},"img":{"alt_text":"Advances in high-resolution cryo-EM at 100 kV","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2117,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-cryo-electron-tomography-expand-the-capabilities-of-quantitative-cell-biology\/","url_meta":{"origin":524,"position":1},"title":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology","author":"Vinay S","date":"September 29, 2026","format":false,"excerpt":"Key takeaways Cryo-electron tomography has largely been seen as a qualitative method because cryo-ET data segmentation has been a highly intensive, manual process. Recent advances in deep-learning-based segmentation have expanded the capabilities of cryo-electron tomography, supporting quantitative analysis of cellular structures. A recent webinar by Professor Danielle Grotjahn highlights how\u2026","rel":"","context":"In &quot;Cryo EM Techniques&quot;","block_context":{"text":"Cryo EM Techniques","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-techniques\/"},"img":{"alt_text":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1935,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/fragment-based-drug-discovery-of-drug-targets-membrane-proteins-with-cryo-em\/","url_meta":{"origin":524,"position":2},"title":"Fragment based drug discovery meets challenging drug targets with high-throughput cryo-EM\u00a0","author":"Swarnim Rawat","date":"December 12, 2025","format":false,"excerpt":"Benefits of FBDD in the search for novel therapeutics\u00a0 Fragment-based drug discovery (FBDD) is a method that screens a large quantity of protein fragments for their potential as small molecule therapeutics. This approach was previously hampered by the slow throughput of crystallization for the characterization of potential leads. The increasing\u2026","rel":"","context":"In &quot;Cryo EM Drug Discovery&quot;","block_context":{"text":"Cryo EM Drug Discovery","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-drug-discovery\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2172,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","url_meta":{"origin":524,"position":3},"title":"What is Subtomogram Averaging?","author":"Swarnim Rawat","date":"October 19, 2026","format":false,"excerpt":"Turning crowded cryo-ET data into structural insight with subtomogram averaging Cryo-electron tomography (cryo-ET) is capable of capturing detailed, three-dimensional views of vitrified biological samples, supporting a broad range of life sciences research. Subtomogram averaging helps refine that crowded data for clearer structural insight by finding repeated particles, extracting them as\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/cancer-research\/"},"img":{"alt_text":"Social Cryo EM","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2143,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/microscopy-image-analysis-with-amira-software-ai-in-cell-biology\/","url_meta":{"origin":524,"position":4},"title":"Four ways AI is making microscopy image analysis easier for cell biologists","author":"Alejandra Sanchez-Erostegui","date":"October 14, 2026","format":false,"excerpt":"Key takeaways Modern microscopes are capable of generating large volumes of high-resolution data, which is highly valuable for cell biology research, but also makes it increasingly more laborious and difficult to extract meaningful scientific information from the whole dataset.\u00a0 Artificial intelligence is well positioned to support this work by streamlining\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Four ways AI is making microscopy image analysis easier for cell biologists.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2016,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/how-artificial-intelligence-ai-improves-image-analysis-workflows-in-life-sciences\/","url_meta":{"origin":524,"position":5},"title":"How artificial intelligence (AI) improves image analysis workflows in life sciences","author":"Vinay S","date":"June 2, 2026","format":false,"excerpt":"Image acquisition is not the end of the story\u2014it is the starting point. Once images are captured, researchers typically move into preprocessing to improve quality, then they perform visualization, segmentation, and quantitative analysis to extract meaningful measurements. The goal is simple: turn images into understanding. In practice, however, image analysis\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"How artificial intelligence (AI) improves image analysis workflows in life sciences","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/04\/Selectris.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/524","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/users\/954"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/comments?post=524"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/524\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media\/525"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media?parent=524"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/categories?post=524"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/tags?post=524"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/division?post=524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}