{"id":695,"date":"2022-04-11T20:26:27","date_gmt":"2022-04-11T20:26:27","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?p=695"},"modified":"2022-05-31T20:32:46","modified_gmt":"2022-05-31T20:32:46","slug":"cryo-em-tau-protein-structure-studies","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/","title":{"rendered":"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries"},"content":{"rendered":"<p>From Alzheimer\u2019s disease to dementia, neurodegenerative disorders caused by folds in the protein tau affect <a href=\"https:\/\/www.niehs.nih.gov\/research\/supported\/health\/neurodegenerative\/index.cfm\">millions of people<\/a> around the world. Here, we showcase some of the most recent cryo-EM tau protein structure findings sure to pave the way for drug discovery and therapeutics development.<\/p>\n<p><a href=\"https:\/\/ter.li\/cz356h\"><em>Watch our recent webinar about the latest tau findings from researchers Sofia L\u00f6vestam and Yang Shi at MRC Laboratory of Molecular Biology and Abhay Kotecha from Thermo Fisher Scientific &gt;&gt;<\/em><\/a><\/p>\n<h2 style=\"font-size: 100%;\"><strong>Cryo-EM tau studies <\/strong><strong>unravel neurodegenerative tauopathy diseases classification<\/strong><\/h2>\n<p>Tau typically adopts a specific structure that contributes to the normal functioning of cells in the brain. Yet in a class of neurodegenerative diseases called tauopathies, misfolded tau molecules stack together to form needle-shaped fibrils\u2014which can take on different 3D structural forms.<\/p>\n<p>In a series of recent groundbreaking cryo-EM studies, a global group of scientists including lead contributors from MRC Laboratory of Molecular Biology, Thermo Fisher Scientific, and Tokyo Metropolitan Institute of Medical Science, continue to examine how tau cease their usual protective function and end up aggregating inside neurons to form large tangles that cause the damaged cells seen in the brains of affected patients.<\/p>\n<p>The first study of note was published in <a href=\"https:\/\/www.nature.com\/articles\/s41586-021-03911-7\"><em>Nature<\/em><\/a> in September 2021, which defined different neurodegenerative diseases based on the structural strains of misfolded tau protein.<\/p>\n<p>Using cryo-EM, scientists obtained high-resolution images of different forms of tau fibrils purified from the post-mortem brains of people suffering from nine different neurodegenerative diseases. They used our powerful <a href=\"https:\/\/ter.li\/lqcz9h\">Thermo Scientific Krios G4 Cryo-TEM<\/a> equipped with the new E-CFEG, <a href=\"https:\/\/ter.li\/cnshai\">Selectris X Imaging Filter<\/a> and <a href=\"https:\/\/ter.li\/u5l3ak\">Falcon IV Direct Electron Detector<\/a>, which helped them to achieve high resolutions structures of these tau filaments.<\/p>\n<div id=\"attachment_2180\" style=\"width: 490px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2180\" class=\"size-full wp-image-2180\" title=\"Structural classification of Tau protein folds\" src=\"https:\/\/admin.acceleratingscience.com\/microscopy\/wp-content\/uploads\/sites\/12\/2022\/04\/Tau-blog.jpg\" alt=\"Structural classification of Tau protein folds\" width=\"480\" height=\"249\" \/><p id=\"caption-attachment-2180\" class=\"wp-caption-text\">Structural classification of Tau protein folds that leads to different diseases called tauopathies (Image courtesy MRC, UK).<\/p><\/div>\n<p>Based on this information, the group classified neurodegenerative diseases based on the different 3D structures of the fibrils including progressive supranuclear palsy (PSP), globular glial tauopathy (GGT), argyrophilic grain disease (AGD), familial British dementia (FBD), and familial Danish dementia (FDD), among others. This study builds on previous research that defined four neurodegenerative diseases\u2014Alzheimer\u2019s disease (AD), Pick\u2019s disease, chronic traumatic encephalopathy (CTE), and corticobasal degeneration (CBD)\u2014by analyzing the 3D structure of the corresponding tau fibrils.<\/p>\n<h2 style=\"font-size: 100%;\"><strong>Identification of new protein forming amyloid filaments in the brain<\/strong><\/h2>\n<p>In November 2021, <a href=\"https:\/\/www.biorxiv.org\/content\/10.1101\/2021.11.09.467923v1\">the team published their next study<\/a> of potential relationships between various folds and neurodegenerative diseases.<\/p>\n<p>Their cryo-EM structure shows that residues 120-254 of the lysosomal type II transmembrane protein (TMEM106B) also form amyloid filaments in the human brain. They solved cryo-EM structures of these filaments from the brains of individuals with neurodegenerative conditions as well as from the brains of neurologically normal individuals and observed three different folds with no clear relationship between folds and disease. They did however find the presence of TMEM106B filaments in the brains of older, but not younger, neurologically normal individuals, indicating that they form in an age-dependent manner.<\/p>\n<h2 style=\"font-size: 100%;\"><strong>High-resolution structure of amyloid beta filament central to Alzheimer&#8217;s diseases <\/strong><\/h2>\n<p>One of the mysteries of Alzheimer\u2019s etiology is the folding of aggregates formed by amyloid-\u03b2 peptides in the human brain. The assembly of A\u03b2 peptides into filaments is a central event in this disease. In January 2022, researchers <a href=\"https:\/\/www.science.org\/doi\/10.1126\/science.abm7285\">solved this mystery<\/a>, revealing two S-shaped protofilament formed in the human brain each associated with either sporadic or familial Alzheimer\u2019s.<\/p>\n<p>These structures help further our understanding of the development of amyloid diseases and will be vital for designing disease-modifying therapeutic agents with increased specificity and sensitivity.<\/p>\n<p>\u201cCryo-EM has revealed distinct amyloid structures in many neurodegenerative diseases, and that model systems of disease often do not replicate these structures. In order to better understand what role the different amyloid structures play in disease, more relevant model systems will need to be developed. Thereby, cryo-EM structure determination will continue to be crucial in the study of neurodegeneration,&#8221; said author Sjors Scheres.<\/p>\n<h2 style=\"font-size: 100%;\"><strong>76 cryo-EM structures of tau filaments solved: a \u201cscientific tour-de-force\u201d <\/strong><\/h2>\n<p>A lack of laboratory-based model systems to generate the structures of tau filaments from the human brain has, to date, hampered efforts to uncover the molecular mechanisms that underlie tauopathies.<\/p>\n<p>In March 2022, the team led by Sjors Scheres and Michel Goedert at MRC Laboratory of Molecular Biology and the applications development team at Thermo Fisher Scientific published a <a href=\"https:\/\/elifesciences.org\/articles\/76494\">record-breaking 76 structures of recombinant tau filaments<\/a> assembled <em>in vitro<\/em> that replicate the structures of filaments from both Alzheimer\u2019s disease and CTE.<\/p>\n<div id=\"attachment_2191\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2191\" class=\"size-large wp-image-2191\" title=\"Cross-sections used in cryo-electron microscopy (cryo-EM) reconstructions\" src=\"https:\/\/admin.acceleratingscience.com\/microscopy\/wp-content\/uploads\/sites\/12\/2022\/04\/elife-76494-fig1-figsupp1-v2-821x1024.jpg\" alt=\"Cross-sections used in cryo-electron microscopy (cryo-EM) reconstructions\" width=\"760\" height=\"948\" \/><p id=\"caption-attachment-2191\" class=\"wp-caption-text\">Cross-sections for all cryo-EM structures described in <a href=\"https:\/\/elifesciences.org\/articles\/76494#fig1s1\" target=\"_blank\" rel=\"noopener\">the following paper<\/a> resulting in ~4.7 \u00c5 resolution reconstructions.<\/p><\/div>\n<p>Scientists showed that post-translational modifications of tau modulate filament assembly, and that previously observed additional densities in Alzheimer\u2019s and CTE filaments may arise from the presence of inorganic salts, like phosphates and sodium chloride. <em>In vitro <\/em>assembly of tau into disease-relevant filaments will facilitate studies to determine their roles in different diseases, as well as the development of compounds that specifically bind to these structures or prevent their formation. These findings suggest that molecular structures of tau tangles are key to understanding the various neurological diseases and will have large implications for the diagnosis and treatment of these diseases in future.<\/p>\n<p>\u201cCryo-EM emerged as a powerful tool to investigate previously intractable and complex biological machineries, elucidating their physiological and pathophysiological role,\u201d said Abhay Kotecha, Manager of Application Scientists at Thermo Fisher. \u201cCryo-EM tau protein structure findings are accelerating at a rapid pace and will collectively provide a framework for the development of novel therapeutics against neurodegenerative disorders.\u201d<\/p>\n<p><em>Leah Lavery is a Senior Manager of Market Development at Thermo Fisher Scientific.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>From Alzheimer\u2019s disease to dementia, neurodegenerative disorders caused by folds in the protein tau affect millions of people around the world. Here, we showcase some of the most recent cryo-EM tau protein structure findings sure to pave the way for drug discovery and therapeutics development. Watch our recent webinar about the latest tau findings from<\/p>\n","protected":false},"author":1191,"featured_media":696,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[24,51,33],"tags":[34,15,16,117],"division":[],"class_list":["post-695","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cryo-electron-microscopy-cryo-em","category-customer-spotlights","category-general","tag-alzheimers","tag-cryo-electron-microscopy","tag-cryo-em","tag-drug-discovery","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Cryo-EM Tau - Tauopathy - Cryo-EM - Life in Atomic Resolution<\/title>\n<meta name=\"description\" content=\"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries\" \/>\n<meta property=\"og:description\" content=\"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/\" \/>\n<meta property=\"og:site_name\" content=\"Life in Atomic Resolution\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-11T20:26:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-05-31T20:32:46+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Leah Lavery\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Leah Lavery\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/\"},\"author\":{\"name\":\"Leah Lavery\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/d10ff6b58e754d0958ae6fb3ba11b14b\"},\"headline\":\"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries\",\"datePublished\":\"2022-04-11T20:26:27+00:00\",\"dateModified\":\"2022-05-31T20:32:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/\"},\"wordCount\":949,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/05\\\/Tau-april-blog-feature.png\",\"keywords\":[\"Alzheimer's\",\"cryo-electron microscopy\",\"cryo-EM\",\"drug discovery\"],\"articleSection\":[\"Cryo-Electron Microscopy (Cryo-EM)\",\"Customer Spotlights\",\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/\",\"name\":\"Cryo-EM Tau - Tauopathy - Cryo-EM - Life in Atomic Resolution\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/05\\\/Tau-april-blog-feature.png\",\"datePublished\":\"2022-04-11T20:26:27+00:00\",\"dateModified\":\"2022-05-31T20:32:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/d10ff6b58e754d0958ae6fb3ba11b14b\"},\"description\":\"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/05\\\/Tau-april-blog-feature.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/wp-content\\\/uploads\\\/sites\\\/22\\\/2022\\\/05\\\/Tau-april-blog-feature.png\",\"width\":1200,\"height\":630,\"caption\":\"Cryo-EM tau protein structure studies unravel neurodegenerative disease mysteries\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/cryo-em-tau-protein-structure-studies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/\",\"name\":\"Life in Atomic Resolution\",\"description\":\"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/atomic-resolution\\\/#\\\/schema\\\/person\\\/d10ff6b58e754d0958ae6fb3ba11b14b\",\"name\":\"Leah Lavery\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g\",\"caption\":\"Leah Lavery\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/leahlavery\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Cryo-EM Tau - Tauopathy - Cryo-EM - Life in Atomic Resolution","description":"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/","og_locale":"en_US","og_type":"article","og_title":"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries","og_description":"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.","og_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/","og_site_name":"Life in Atomic Resolution","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-04-11T20:26:27+00:00","article_modified_time":"2022-05-31T20:32:46+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","type":"image\/png"}],"author":"Leah Lavery","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Leah Lavery","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#article","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/"},"author":{"name":"Leah Lavery","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/d10ff6b58e754d0958ae6fb3ba11b14b"},"headline":"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries","datePublished":"2022-04-11T20:26:27+00:00","dateModified":"2022-05-31T20:32:46+00:00","mainEntityOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/"},"wordCount":949,"commentCount":0,"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","keywords":["Alzheimer's","cryo-electron microscopy","cryo-EM","drug discovery"],"articleSection":["Cryo-Electron Microscopy (Cryo-EM)","Customer Spotlights","General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/","name":"Cryo-EM Tau - Tauopathy - Cryo-EM - Life in Atomic Resolution","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website"},"primaryImageOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#primaryimage"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","datePublished":"2022-04-11T20:26:27+00:00","dateModified":"2022-05-31T20:32:46+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/d10ff6b58e754d0958ae6fb3ba11b14b"},"description":"Neurodegenerative disorders caused by tau protein folds affect millions. Here, we showcase recent cryo-EM tau protein structure findings.","breadcrumb":{"@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","width":1200,"height":630,"caption":"Cryo-EM tau protein structure studies unravel neurodegenerative disease mysteries"},{"@type":"BreadcrumbList","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-em-tau-protein-structure-studies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/"},{"@type":"ListItem","position":2,"name":"Advances in Cryo-EM Tau Protein Structure Studies Unravel Neurodegenerative Mysteries"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#website","url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/","name":"Life in Atomic Resolution","description":"Electron and cryo-electron microscopy stories and solutions about the advancement of cellular and structural biology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/#\/schema\/person\/d10ff6b58e754d0958ae6fb3ba11b14b","name":"Leah Lavery","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/556fbf75b49a1d49dbcca690062552894d5854740ff1464e6b4d5b2500756b21?s=96&d=mm&r=g","caption":"Leah Lavery"},"url":"https:\/\/admin.acceleratingscience.com\/author\/leahlavery\/"}]}},"taxonomy_info":{"category":[{"value":24,"label":"Cryo-Electron Microscopy (Cryo-EM)"},{"value":51,"label":"Customer Spotlights"},{"value":33,"label":"General"}],"post_tag":[{"value":34,"label":"Alzheimer's"},{"value":15,"label":"cryo-electron microscopy"},{"value":16,"label":"cryo-EM"},{"value":117,"label":"drug discovery"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature-1024x538.png",760,399,true],"author_info":{"display_name":"Leah Lavery","author_link":"https:\/\/admin.acceleratingscience.com\/author\/leahlavery\/"},"comment_info":0,"category_info":[{"term_id":24,"name":"Cryo-Electron Microscopy (Cryo-EM)","slug":"cryo-electron-microscopy-cryo-em","term_group":0,"term_taxonomy_id":24,"taxonomy":"category","description":"","parent":0,"count":79,"filter":"raw","meta":[],"cat_ID":24,"category_count":79,"category_description":"","cat_name":"Cryo-Electron Microscopy (Cryo-EM)","category_nicename":"cryo-electron-microscopy-cryo-em","category_parent":0},{"term_id":51,"name":"Customer Spotlights","slug":"customer-spotlights","term_group":0,"term_taxonomy_id":51,"taxonomy":"category","description":"","parent":0,"count":36,"filter":"raw","meta":[],"cat_ID":51,"category_count":36,"category_description":"","cat_name":"Customer Spotlights","category_nicename":"customer-spotlights","category_parent":0},{"term_id":33,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":33,"taxonomy":"category","description":"","parent":0,"count":59,"filter":"raw","meta":[],"cat_ID":33,"category_count":59,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":34,"name":"Alzheimer's","slug":"alzheimers","term_group":0,"term_taxonomy_id":34,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":15,"name":"cryo-electron microscopy","slug":"cryo-electron-microscopy","term_group":0,"term_taxonomy_id":15,"taxonomy":"post_tag","description":"","parent":0,"count":62,"filter":"raw","meta":[]},{"term_id":16,"name":"cryo-EM","slug":"cryo-em","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":63,"filter":"raw","meta":[]},{"term_id":117,"name":"drug discovery","slug":"drug-discovery","term_group":0,"term_taxonomy_id":117,"taxonomy":"post_tag","description":"","parent":0,"count":18,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":1935,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/fragment-based-drug-discovery-of-drug-targets-membrane-proteins-with-cryo-em\/","url_meta":{"origin":695,"position":0},"title":"Fragment based drug discovery meets challenging drug targets with high-throughput cryo-EM\u00a0","author":"Swarnim Rawat","date":"December 12, 2025","format":false,"excerpt":"Benefits of FBDD in the search for novel therapeutics\u00a0 Fragment-based drug discovery (FBDD) is a method that screens a large quantity of protein fragments for their potential as small molecule therapeutics. This approach was previously hampered by the slow throughput of crystallization for the characterization of potential leads. The increasing\u2026","rel":"","context":"In &quot;Cryo EM Drug Discovery&quot;","block_context":{"text":"Cryo EM Drug Discovery","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-drug-discovery\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/12\/blog-8-banner-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1854,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-100-kv-high-resolution-cryo-em-single-particle-analysis\/","url_meta":{"origin":695,"position":1},"title":"Advances in high-resolution cryo-EM at 100 kV","author":"Swarnim Rawat","date":"February 5, 2026","format":false,"excerpt":"100 kV cryo-TEM enables high-resolution single particle analysis Within the past decade, cryo-electron microscopy (cryo-EM) techniques have revolutionized structural biology by enabling the visualization of challenging molecular and sub-cellular structures in their near-native states at high resolution. These valuable observations have, until recently, been relegated to advanced 300 kV instruments\u2026","rel":"","context":"In &quot;Cryo-Electron Microscopy (Cryo-EM)&quot;","block_context":{"text":"Cryo-Electron Microscopy (Cryo-EM)","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/"},"img":{"alt_text":"Advances in high-resolution cryo-EM at 100 kV","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2025\/08\/Blog-Tundra-Preprint-1858725-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2117,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/advances-in-cryo-electron-tomography-expand-the-capabilities-of-quantitative-cell-biology\/","url_meta":{"origin":695,"position":2},"title":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology","author":"Vinay S","date":"September 29, 2026","format":false,"excerpt":"Key takeaways Cryo-electron tomography has largely been seen as a qualitative method because cryo-ET data segmentation has been a highly intensive, manual process. Recent advances in deep-learning-based segmentation have expanded the capabilities of cryo-electron tomography, supporting quantitative analysis of cellular structures. A recent webinar by Professor Danielle Grotjahn highlights how\u2026","rel":"","context":"In &quot;Cryo EM Techniques&quot;","block_context":{"text":"Cryo EM Techniques","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/cryo-em-techniques\/"},"img":{"alt_text":"Advances in cryo-electron tomography expand the capabilities of quantitative cell biology.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/09\/blog-cryo-em-series-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2172,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/what-is-subtomogram-averaging\/","url_meta":{"origin":695,"position":3},"title":"What is Subtomogram Averaging?","author":"Swarnim Rawat","date":"October 19, 2026","format":false,"excerpt":"Turning crowded cryo-ET data into structural insight with subtomogram averaging Cryo-electron tomography (cryo-ET) is capable of capturing detailed, three-dimensional views of vitrified biological samples, supporting a broad range of life sciences research. Subtomogram averaging helps refine that crowded data for clearer structural insight by finding repeated particles, extracting them as\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/cancer-research\/"},"img":{"alt_text":"Social Cryo EM","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/social.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2143,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/microscopy-image-analysis-with-amira-software-ai-in-cell-biology\/","url_meta":{"origin":695,"position":4},"title":"Four ways AI is making microscopy image analysis easier for cell biologists","author":"Alejandra Sanchez-Erostegui","date":"October 14, 2026","format":false,"excerpt":"Key takeaways Modern microscopes are capable of generating large volumes of high-resolution data, which is highly valuable for cell biology research, but also makes it increasingly more laborious and difficult to extract meaningful scientific information from the whole dataset.\u00a0 Artificial intelligence is well positioned to support this work by streamlining\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"Four ways AI is making microscopy image analysis easier for cell biologists.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/10\/fault-localization-root-cause-ai-packaging-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2016,"url":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/how-artificial-intelligence-ai-improves-image-analysis-workflows-in-life-sciences\/","url_meta":{"origin":695,"position":5},"title":"How artificial intelligence (AI) improves image analysis workflows in life sciences","author":"Vinay S","date":"June 2, 2026","format":false,"excerpt":"Image acquisition is not the end of the story\u2014it is the starting point. Once images are captured, researchers typically move into preprocessing to improve quality, then they perform visualization, segmentation, and quantitative analysis to extract meaningful measurements. The goal is simple: turn images into understanding. In practice, however, image analysis\u2026","rel":"","context":"In &quot;Amira Software&quot;","block_context":{"text":"Amira Software","link":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/cryo-electron-microscopy-cryo-em\/amira-software\/"},"img":{"alt_text":"How artificial intelligence (AI) improves image analysis workflows in life sciences","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2026\/06\/amira-ai-tools-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/atomic-resolution\/wp-content\/uploads\/sites\/22\/2022\/05\/Tau-april-blog-feature.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/users\/1191"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/comments?post=695"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/posts\/695\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media\/696"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/media?parent=695"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/categories?post=695"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/tags?post=695"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/atomic-resolution\/wp-json\/wp\/v2\/division?post=695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}