{"id":12041,"date":"2019-02-25T20:20:36","date_gmt":"2019-02-25T20:20:36","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=12041"},"modified":"2020-05-28T19:15:19","modified_gmt":"2020-05-28T19:15:19","slug":"fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/","title":{"rendered":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing"},"content":{"rendered":"<p>Dr. Tim Inglis shares with us his findings on FAST methods of antibiotic resistance detection and most recently, on <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry.html?icid=BID_FCIST_PJT3273_flow\">flow cytometry<\/a>-assisted antimicrobial susceptibility testing using the \u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-acoustic-focusing-flow-cytometer.html?icid=BID_FCIST_PJT3273_attune1\">Attune NxT Flow Cytometer<\/a>.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/timinglis.jpg\" \/><strong>Tim Inglis, Ph.D.<br \/>\n<\/strong>Dr. Tim Inglis works at the School of Medicine at the University of Western Australia and the School of Biomedical Sciences where his research team is based. He also works at the state pathology service, PathWest Laboratory Medicine, all located on the Queen Elizabeth II Medical Campus. Dr. Inglis\u2019 research is principally concerned with sepsis and antimicrobial resistance.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>What drew you to this area of research?<\/strong><\/h2>\n<p>What drew me to this area of research goes back to the mid 1980s when a colleague of mine was working with a very early flow cytometer on the aggregation of <em>Staphylococci<\/em> in liquids. Then since that, I\u2019ve had a longstanding interest in applications of flow cytometry to bacteriology.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>You have recently published on a new method. Can you describe your publication?<\/strong><\/h2>\n<p>The new method group we published on is known as <a href=\"http:\/\/www.news.uwa.edu.au\/201705269643\/research\/prof-tim-inglis-publishes-new-method-rapid-profiling-antibiotic-resistant-bact\">FAST<\/a>. It\u2019s flow cytometry-assisted antimicrobial susceptibility testing or FAST for short. It uses an <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/acoustic-focusing-technology-overview.html?icid=BID_FCIST_PJT3273_acoustic\">acoustic flow cytometer<\/a> to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Can you describe the significance of this?<\/strong><\/h2>\n<p>The significance is a combination of two things. It\u2019s principally about achieving the same accuracy as the standard methods that are used in clinical laboratories around the world, but doing so in a much shorter time because severe and invasive bacterial infections are time-critical medical emergencies. No doctor is going to want to wait two to three days for an answer that he or she could get in a matter of a few hours or even a few minutes. That\u2019s why our FAST method is very important because it achieves accuracy in a much shorter period of time.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>As far as the FAST methodology, what are your next steps?<\/strong><\/h2>\n<p>There are three key components to this. One is to push for high throughput and automate so that handling of samples can be done on a much larger scale as a clinical laboratory would expect. We obviously also need to expand our repertoire of drug\/bug combinations, and that\u2019s something we\u2019re already working on. The third thing is to simplify the procedures and to get them into a form that can easily be used by technical staffing clinical laboratories.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Let\u2019s talk about your flow cytometry workflow and how you use flow cytometry in your research. <\/strong><\/h2>\n<p>Our initial use of flow cytometry in our research has been mainly focused on a discovery process. We\u2019ve used the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-acoustic-focusing-flow-cytometer.html?icid=BID_FCIST_PJT3273_attune2\">Attune NxT Flow Cytometer<\/a> for us to discover how better to do susceptibility testing. That led us to specific discoveries about how we should prepare our specimens and bacteria, how we clean them up, how we expose them to the fluorescent dyes that are detected on different channels of the flow cytometer. Then the addition of the reagents, in this case, the antibiotics that give us the changes that can be detected by flow cytometry in a short period of time.<\/p>\n<p>After the fluid handling process has been completed by the acoustic flow cytometer, we then obviously proceed to a data analysis step. That gives us the critical differentiation between susceptible and non-susceptible bacteria. We\u2019ve also used a digital microscope to give us a useful extra set of subjective insights into the processes that are going on. This, for microbiologists, is very much sticking within our comfort zone because flow cytometry is not the traditional province of clinical microbiologists. Microscopes obviously are. Incorporating that in the discovery workflow has been an important part of where this has gone so far and is reflected in the first publication that my colleagues have produced on the FAST method.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>In adopting flow cytometry, it\u2019s not a traditional tool. Could you comment on how difficult or easy it was for you to start using flow cytometry and why you chose that method?<\/strong><\/h2>\n<p>The difficulties of moving into flow cytometry have been something that I personally experienced since the mid 1980s. The initial equipment that was available then clearly wasn\u2019t suitable for the task of susceptibility testing. It was only in the 1990s that a small number of experts started to propose that flow cytometry should be used for antimicrobial susceptibility testing. Even then, the accuracy of conventional hydrodynamic flow cytometers was not sufficient to produce reliable results in the kind of time frame that was going to make a difference clinically.<\/p>\n<p>We\u2019ve had to overcome some of those road bumps. The speed bumps that got in the way were accuracy in bacterial cell size range, also issues of background noise, and contamination with particulate material. Some of these obstacles to progress are familiar to those people who set up molecular diagnostics. They\u2019re not the same, but they were a similar quality and magnitude of problems.<\/p>\n<p>Since then, now that we\u2019ve got those problems out of the way, we\u2019re progressing much more quickly to expanding the test repertoire of bug\/drug combinations that I mentioned earlier.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Can you comment on your use of the Attune NxT Flow Cytometer in your research and in the FAST method?<\/strong><\/h2>\n<p>Our use of the Attune NxT Flow Cytometer, it\u2019d be fair to say, is very much at front and center of where we\u2019ve taken this development process. We wouldn\u2019t have got to this area without acoustic flow cytometry. The additional accuracy of the Attune [NxT] has been a critical step in overcoming those principal obstacles to analyzing bacteria at a single cell level.<\/p>\n<p>The [Attune] NxT has given us additional channels for much more specific analysis of different color dyes. Whilst we started with one-color dye with SYTO 9 and got some very good results with that, the options that were given as a result of being able to multiplex with more than one dye and on additional channels open up a much wider range of potential tests to it.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"Attune NxT Flow Cytometer\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/timingliss1.jpg\" alt=\"Use of the Attune NxT Flow Cytometer in the FAST method\" width=\"572\" height=\"321\" \/><\/p>\n<h2><\/h2>\n<h2><strong>Would you consider the Attune NxT Flow Cytometer to be a significant breakthrough or innovation for you in your research?<\/strong><\/h2>\n<p>The Attune NxT is clearly a significant breakthrough, and I can speak from something like three decades of on-and-off use. You could say even a love-hate affair with flow cytometry, a desire to use flow cytometry for clinical bacteriology but frustrated by the limitations of the technology.<\/p>\n<p>The Attune NxT has given us an opportunity to analyze bacteria at a single cell level. And in combination with the range of vital dyes available to us, it\u2019s expanded the potential repertoire of culture-independent bacteriology well beyond the boundaries that are set by molecular biology and in particular, by real-time PCR.<\/p>\n<p>It really is beginning to look like bacterial cytomics are here to stay, and the Attune NxT has been the critical piece of technology.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Could you comment about your satisfaction with working with Thermo Fisher Scientific?<\/strong><\/h2>\n<p>We\u2019ve been very comfortable working with Thermo Fisher Scientific for the last four years. We have a collaboration arrangement that goes back over three and a half years and has taken us from initial, in some cases, accidental\/ serendipitous discoveries, to a point where the technology we\u2019re working on is being adopted by internationally respected reference laboratories overseas. That\u2019s very unusual for a group based in somewhere as geographically isolated as Western Australia. This collaboration is a very unusual one, at least, for us locally and has been a very productive one.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"flow cytometry-assisted antimicrobial susceptibility testing\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/timingliss2.jpg\" alt=\"Using flow cytometry for the FAST method\" width=\"572\" height=\"321\" \/><\/p>\n<h2><\/h2>\n<h2><strong>Could you describe your workflow for the FAST method?<\/strong><\/h2>\n<p>In essence, what we do is recover bacteria, suspend them in a suspension that can be analyzed with a minimum of background noise by the Attune [NxT] Flow Cytometer, and then we expose the bacteria to antibiotics. We treat the bacteria with a vital dye that is taken up and gives the flow cytometer the opportunity to see those bacteria.<\/p>\n<p>We analyze using the software that\u2019s preinstalled and generate a series of gated populations, and then we do further downstream analysis on those gated populations to understand the shift in the size, shape and color intensity of those bacterial populations as a response to antibiotics.<\/p>\n<p>What we\u2019re demonstrating with the Attune [NxT] Flow Cytometer is a change that is precipitated by exposure to different concentrations of antibiotics. This is very similar to but much faster than the conventional culture-based methods of MIC determination, minimum inhibitory concentration.<\/p>\n<p>We believe that it\u2019s much more accurate though because the end point is far more clearly determined and at the very least, is as accurate and probably, in some sense, is more accurate than conventional broth microdilution techniques.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>What is the time difference of doing your FAST method as compared to a traditional method?<\/strong><\/h2>\n<p>The time differential between FAST MIC and broth microdilution MIC, the international reference standard is approximately 18-24 hours at the moment. What would normally take for the international standard 24 hours takes us just less than three hours with manual fluid handling. Now some of that, of course, is as a result of exposure to antibiotic, time being incorporated into the process. The qualitative result that can be obtained, which is more akin to a break point susceptibility can be achieved in as little as less than 30 minutes. With automation, obviously, some of that manual fluid handling could be removed from the process. We anticipate at some point in the future that a leaner process will emerge out of this as standard operating procedure, if you like, which will take some of that time frame out of the overall workflow.<\/p>\n<p>At the moment, we realize that we are best-in-class. We\u2019re keen to remain ahead of the rest of the field and we do believe that there are some points in which we can further improve the system that we\u2019re currently using.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Can you describe the type of samples that you\u2019re testing?<\/strong><\/h2>\n<p>The samples that we\u2019re currently getting and testing are suspensions of bacteria, which, for reasons of meeting regulatory standards, have been recovered from stock culture collections. There is a standard ATCC set of criteria for recovering those organisms. One of my colleagues, <a href=\"https:\/\/www.youtube.com\/watch?v=jgdpI31tVsE\">Kieran Mulroney<\/a>, has already presented at international meetings on application to a sterile fluid specimen from a subject with CAPD-peritonitis. We believe that there are a number of clinical applications for this where we could, at some point in the future, be looking at direct application of the FAST method to clinical specimens. For the moment, at least, in order to meet the validation standards and expectations, we\u2019re working on primary isolates: initial isolates recovered on solid or in liquid media, washing those organisms, and then taking them through to a FAST susceptibility result.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>It sounds like you\u2019re very heavily involved in taking the basic research and translating that into a clinical assay. Could you discuss that briefly?<\/strong><\/h2>\n<p>Certainly. Taking a discovery through to implementation and adoption in practice is often a very lengthy process. Taking an antimicrobial susceptibility test process from its baseline discovery is a new innovation to readiness in the clinical laboratories, restricted at certain stages by the expectations of regulatory agencies like the FDA and here, there\u2019s an organization called the Therapeutic Goods Administration. We need to meet those regulatory standards, and that requires not only training the equipment to do the job that we need to do and convincing ourselves that this is the way to go, but an assay method has to be properly written up. It has to be validated with an extensive collection of representative bacterial isolates. That we\u2019ve done for one drug\/bug combination and have published on that. We\u2019re in the process of working with colleagues who collaborated with us on that first publication to complete independent verification of the validation process that we have already undertaken. That then needs to be done for all of the drug\/bug combinations that we work on.<\/p>\n<p>You\u2019ve got to have a real focus on the clinical benefits and the needs of doing this sort of work in a clinical laboratory environment, in a pathology laboratory service to understand why it\u2019s so important to meet those validation standards.<\/p>\n<p>It is a big task and it requires a very keen focus on that finish line that we are working towards, but as a clinical translational research group, that is very much part and parcel of what we do on this site.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>What do you like most about your Attune NxT Flow Cytometer?<\/strong><\/h2>\n<p>What I like most about the Attune NxT [Flow Cytometer] is its accuracy and its speed of processing. I could list a range of other things that I like about it because we are building up that list as we discover more aspects of its functions, but the core things are speed and accuracy that are not available with hydrodynamic flow cytometers.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Can you describe the advantages of the Attune NxT Flow Cytometer in your assays? <\/strong><\/h2>\n<p>I guess the principal advantage of the Attune NxT [Flow Cytometer] has been accuracy in the bacterial particle size range, so the ability to do accurate cellular analysis across a range of different acquisition wave lengths. The ability therefore to generate the baseline data rapidly in a format that can easily be analyzed with third-party software to take things on to a much higher plane. In particular, for our FAST assays, the ability to quickly describe the unexposed, morphotype the UCM that was described in <a href=\"https:\/\/www.nature.com\/articles\/s41598-017-02009-3\">Mulroney and Hall, et al<\/a>., the first paper on this technique.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>What other clinical specimens do you work with?<\/strong><\/h2>\n<p>We are working with a range of additional clinical specimens, and I think the most notable one that we are most excited about is blood cultures. Invasive infections require blood culture processing. A subject with sepsis will have a blood culture taken. Traditionally, this will take, in our center, a median of 18 hours before it flags positive. After collection it may take anywhere between two to three days before the susceptibility results become known.<\/p>\n<p>We\u2019ve run a pilot study using our FAST technique, and in that pilot study of 30 consecutive blood culture positives, all of the gram-negatives that we analyzed were correctly called by FAST.<\/p>\n<p>Most importantly, this saves us at least 24 hours but more like two days; 48 hours before we get the definitive susceptibility result. We\u2019ve been able to do this across a range of different intravenous antibiotics beyond the carbapenems that were first reported in our initial report on the FAST technique. We\u2019re now confident that we can start applying this to clinical applications and particularly, to invasive infections.<\/p>\n<p>If you bear in mind that every hour\u2019s delay to starting the right antibiotic for a subject with bloodstream infection results in an 8% increase in mortality, you realize that that kind of advance is going to save lives.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Do you use the Autosampler in your workflow?<\/strong><\/h2>\n<p>In the use of the [Attune] NxT, so far, most of our work has been done with manual fluid processing, but we have recently gained access to an <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometers\/attune-acoustic-focusing-flow-cytometer\/attune-nxt-autosampler.html?icid=BID_FCIST_PJT3273_autosampler\">Autosampler<\/a> and we have begun to explore higher throughput processing. I anticipate that the use of auto sampling will enable clinical laboratories to process larger numbers of clinical isolates using a FAST or modified FAST method in the near future.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>What are your hopes for this field of research in the future?<\/strong><\/h2>\n<p>We could spend a long time going over my hopes for bacterial flow cytometry, but I\u2019ve gone down on the record as, I guess, saying two key things. One is that we see the introduction of FAST or flow-assisted susceptibility testing; in its various different forms into clinical practice as quickly as possible because it is going to make a difference. It is going to cause a significant shift to the left on the susceptibility testing timeline. We know that that is critical in combating the disastrous rise of antimicrobial resistance (AMR). AMR is clearly a major global concern.<\/p>\n<p>My second event horizon is the wider application of bacterial flow cytometry to culture-independent diagnostic tests. This is more than just antimicrobial susceptibility testing. This is going to be the application of flow-based methods to detecting the presence of bacteria, accurately enumerating those bacteria and identifying them as well as determining their antimicrobial susceptibilities. That is a dream that some of us started to chase rather boldly in the 1980s but without the tools to do so. We\u2019re starting to see those tools come within our grasp. I look forward to the next five years, which could well see the development of bacterial cytomics, or bacterial flow cytometry, to a similar level as where molecular biology has gone in the field of infectious diseases diagnostics. Thank you.<\/p>\n<p>This work is being performed in the FAST Lab; a collaboration between the UWA School of Biomedical Sciences, and PathWest Laboratory Medicine, supported by Lab Without Walls, Rotary, the Health Department of Western Australia, the Bill &amp; Melinda Gates Foundation and NESTA, UK.<\/p>\n<p>For Research Use Only. Not for use in diagnostic procedures.<\/p>\n<p><!-- BEGIN KAPOST ANALYTICS CODE --><\/p>\n<p><!-- var _kaq = _kaq || []; _kaq.push([2, \"5c6f23718426f4004e0000b3\", \"5674227b963491538f00011d\"]); (function(){ var ka = document.createElement(\"script\"); ka.async=true; ka.id=\"ka_tracker\"; ka.src = (document.location.protocol == \"https:\" ? \"https\" : \"http\") + \":\/\/analytics.kapost.com\/ka.js\"; var s = document.getElementsByTagName(\"script\")[0]; s.parentNode.insertBefore(ka, s); })(); \/\/--><\/p>\n<p><!-- END KAPOST ANALYTICS CODE --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dr. Tim Inglis shares with us his findings on FAST methods of antibiotic resistance detection and most recently, on flow cytometry-assisted antimicrobial susceptibility testing using the \u00a0Attune NxT Flow Cytometer. Tim Inglis, Ph.D. Dr. Tim Inglis works at the School of Medicine at the University of Western Australia and the School of Biomedical Sciences where<\/p>\n","protected":false},"author":120,"featured_media":12045,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172,135],"tags":[210,159,43],"division":[],"class_list":{"0":"post-12041","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"category-immunology","9":"tag-flow-cytometry","10":"tag-immunology","11":"tag-pcr","12":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing<\/title>\n<meta name=\"description\" content=\"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing\" \/>\n<meta property=\"og:description\" content=\"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-02-25T20:20:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-28T19:15:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1286\" \/>\n\t<meta property=\"og:image:height\" content=\"726\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing\",\"datePublished\":\"2019-02-25T20:20:36+00:00\",\"dateModified\":\"2020-05-28T19:15:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/\"},\"wordCount\":2889,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/Flow-Cytometry-header.jpg\",\"keywords\":[\"Flow Cytometry\",\"immunology\",\"PCR\"],\"articleSection\":[\"General\",\"Immunology\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/\",\"name\":\"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/Flow-Cytometry-header.jpg\",\"datePublished\":\"2019-02-25T20:20:36+00:00\",\"dateModified\":\"2020-05-28T19:15:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/Flow-Cytometry-header.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/Flow-Cytometry-header.jpg\",\"width\":1286,\"height\":726},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing","description":"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/","og_locale":"en_US","og_type":"article","og_title":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing","og_description":"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-02-25T20:20:36+00:00","article_modified_time":"2020-05-28T19:15:19+00:00","og_image":[{"width":1286,"height":726,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing","datePublished":"2019-02-25T20:20:36+00:00","dateModified":"2020-05-28T19:15:19+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/"},"wordCount":2889,"commentCount":2,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","keywords":["Flow Cytometry","immunology","PCR"],"articleSection":["General","Immunology"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/","name":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","datePublished":"2019-02-25T20:20:36+00:00","dateModified":"2020-05-28T19:15:19+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Flow cytometry-assisted antimicrobial susceptibility testing to rapidly determine the response of bacteria to antibiotics they\u2019re exposed to.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","width":1286,"height":726},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/fast-flow-cytometry-assisted-antimicrobial-susceptibility-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"FAST: Flow Cytometry-Assisted Antimicrobial Susceptibility Testing"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"},{"value":135,"label":"Immunology"}],"post_tag":[{"value":210,"label":"Flow Cytometry"},{"value":159,"label":"immunology"},{"value":43,"label":"PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header-1024x578.jpg",760,429,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":2,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":172,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":135,"name":"Immunology","slug":"immunology","term_group":0,"term_taxonomy_id":135,"taxonomy":"category","description":"","parent":0,"count":45,"filter":"raw","meta":[],"cat_ID":135,"category_count":45,"category_description":"","cat_name":"Immunology","category_nicename":"immunology","category_parent":0}],"tag_info":[{"term_id":210,"name":"Flow Cytometry","slug":"flow-cytometry","term_group":0,"term_taxonomy_id":210,"taxonomy":"post_tag","description":"","parent":0,"count":18,"filter":"raw","meta":[]},{"term_id":159,"name":"immunology","slug":"immunology","term_group":0,"term_taxonomy_id":159,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]},{"term_id":43,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":43,"taxonomy":"post_tag","description":"","parent":0,"count":142,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19184,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/magnetic-cell-separation-how-to-automate-cell-isolation\/","url_meta":{"origin":12041,"position":0},"title":"Magnetic Cell Separation: How to Automate Cell Isolation","author":"Behind The Bench Staff","date":"October 29, 2025","format":false,"excerpt":"In the rapidly advancing field of medical diagnostics, liquid biopsy stands out as an innovative technique that is advancing the way we detect and monitor diseases. Unlike traditional biopsies, which require invasive procedures to extract tissue samples, liquid biopsy offers a minimally invasive alternative by isolating cells from complex samples\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Automated cell isolation","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19159,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/scalable-molecular-testing-workflows\/","url_meta":{"origin":12041,"position":1},"title":"From Bottlenecks to Breakthroughs: Scaling Molecular Testing with OpenArray","author":"Ashleigh Barlow","date":"October 1, 2025","format":false,"excerpt":"At Livingston Med Lab in central Texas, the team has long prided itself on doing quality molecular medicine work including qPCR, array cards, and infectious disease panels, and always pushing to offer more to its community. But a roadblock emerged when they asked: how do we scale more efficiently without\u2026","rel":"","context":"In &quot;Infectious Diseases&quot;","block_context":{"text":"Infectious Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/infectious-diseases\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Sean-Villasana-is-molecular-lab-supervisor-technical-respresentative-at-Livingston-Med-Lab-1.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19579,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/liquid-biopsy-cancer-research-ngs-pcr\/","url_meta":{"origin":12041,"position":2},"title":"From Discovery to Monitoring: How Sequencing and PCR Work Together in Oncology Research","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"Scientific, joins the Absolute Gene-ius podcast to discuss how molecular technologies are advancing precision oncology research. With experience spanning clinical laboratory research, digital PCR research applications, and next-generation sequencing (NGS), Dr. Sollweck shares how scientists are addressing critical unmet needs in cancer research. From liquid biopsy research strategies to minimal\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Sollweck-headshot-200x250_Jordan-Ruggieri.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":12041,"position":3},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19461,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/grapevine-downy-mildew-fungicide-resistance-detection\/","url_meta":{"origin":12041,"position":4},"title":"Tracking grape pathogens from air to vine \u2013 a conversation with Lexi Heger","author":"Behind The Bench Staff","date":"February 28, 2026","format":false,"excerpt":"On the Absolute Gene-ius podcast, Lexi Heger, PhD candidate in Plant Pathology and Molecular Plant Sciences at Michigan State University, explores the molecular detection of grapevine pathogens and how qPCR and digital PCR (dPCR) are transforming plant disease research. Her research centers on downy mildew of grape (Plasmopara viticola) and\u2026","rel":"","context":"In &quot;Animal Health and AgriGenomics&quot;","block_context":{"text":"Animal Health and AgriGenomics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/animal-health-and-agrigenomics\/"},"img":{"alt_text":"Portrait of a smiling plant pathology researcher standing outdoors beside grapevine leaves.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Heger-headshot-1_Jordan-Ruggieri-scaled.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19566,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/pcr-inhibitors-digital-pcr\/","url_meta":{"origin":12041,"position":5},"title":"When PCR Gets Dirty &#8211; Tackling PCR Inhibitors","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"In this first Absolute Gene-ius: Science Snapshot episode, hosts Jordan Ruggieri and Lisa Crawford revisit expert insights on one persistent molecular biology challenge: PCR inhibitors. Across wastewater surveillance, environmental microbiology, and gene therapy manufacturing, inhibitors can distort PCR data and complicate quantification. Featuring perspectives from Ray Ketchum, PhD; Sarah Philo,\u2026","rel":"","context":"In &quot;Lab Tips and Tricks&quot;","block_context":{"text":"Lab Tips and Tricks","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/lab-tips-and-tricks\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Ketchum-headshot.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/Flow-Cytometry-header.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=12041"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12041\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/12045"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=12041"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=12041"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=12041"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=12041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}