{"id":12062,"date":"2019-02-26T22:34:33","date_gmt":"2019-02-26T22:34:33","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=12062"},"modified":"2019-03-11T18:45:34","modified_gmt":"2019-03-11T18:45:34","slug":"lets-get-specific-about-the-tnfr-pathway","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/","title":{"rendered":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!"},"content":{"rendered":"<p style=\"text-align: left\">By Parveen Dawood and Sarvani Emani<\/p>\n<p style=\"text-align: left\">Learn more about the TNFR pathway and CRISPR-validated* Invitrogen <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/antibodies.html?icid=BID_AISAP_PJT3160_antibodies\" target=\"_blank\" rel=\"noopener noreferrer\">antibodies<\/a>.<\/p>\n<p style=\"text-align: left\"><strong>What is the significance of the TNFR pathway and what are the key proteins?<\/strong><\/p>\n<p style=\"text-align: left\">The TNFR pathway is one of the most studied oncogenic and apoptotic pathways. Tumor necrosis factor-alpha (TNF-alpha) is a proinflammatory cytokine which plays a key role in carcinogenesis, cancer progression, metastasis and immunity. Signaling mediated by TNF through its receptors TNFR1 and TNFR2, is essential for cell proliferation, differentiation, apoptosis, modulation of immune responses and induction of inflammation.<\/p>\n<p style=\"text-align: left\">Binding of the trimeric TNF-alpha to the TNFR1 results in trimerization of the receptor and recruitment of TNFR1-associated death domain protein (TRADD) and receptor-interacting protein (RIP). TRADD further recruits another adaptor protein, TNF-receptor-associated factor 2 (TRAF2). This TNF-alpha receptor complex activates transforming growth factor-\u03b2-activated kinase 1 (TAK1) in a RIP dependent manner. TAK1 leads to the aggregation of a downstream kinase complex \u2013 IKK complex. This complex is composed of the catalytic components- IKK\u03b1 and IKK\u03b2 &#8211; and a regulatory protein, NF-\u03baB essential modifier (NEMO). Inhibitory \u03baB (I\u03baB) tightly regulates nuclear factor-kappaB transcription factor (NF-\u03baBp60 and NF-\u03baBp50). Phosphorylation of I\u03baB by the IKK complex results in the release of the NF-\u03baB transcription factor, followed by ubiquitin-dependent degradation of I\u03baB by the 26S proteosome complex. NF-\u03baB translocates to the nucleus and activates genes involved in cell proliferation and anti-apoptosis. In addition to NF-\u03baB activation, RIP has been suggested as a component of the p38 pathway. TAK1 is known to activate MKK3 which then phosphorylates p38. Phospho-p38 is then imported into the nucleus where it phosphorylates specific transcription factors that activate several stress and growth related genes (Figure 1).<\/p>\n<p><strong>Figure 1 \u2013 TNFR pathway showing downstream effectors<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-12066 alignnone\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig1.jpg\" alt=\"TNFR pathway \" width=\"600\" height=\"645\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig1.jpg 600w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig1-279x300.jpg 279w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<p style=\"text-align: left\"><strong>What methods are used to address antibody specificity?<\/strong><\/p>\n<p style=\"text-align: left\">Testing antibody performance against genetically modified samples is one way to verify that an antibody recognizes a specific target. Measuring the relevant signal in control cells versus cells in which the target gene has been knocked out using CRISPR-Cas9 technology is used to assess <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/antibodies\/invitrogen-antibody-validation.html?icid=BID_AISAP_PJT3160_antibodies\" target=\"_blank\" rel=\"noopener noreferrer\">specificity of the antibody<\/a>. Elimination of target protein expression prevents antibody binding and demonstrates that the antibody is specific. Example of this strategy are shown in Figure 2,3 and 4.<\/p>\n<p style=\"text-align: left\"><strong>Figure 2<\/strong><\/p>\n<p style=\"text-align: left\">Western blot analysis of TRADD (Fig. 1a) was performed using whole cell extracts of ME-180 CAS9 Control (lane 1), ME-180 CAS9 Scrambled (lane 2), ME-180 TNFR1 KO (lane 3) and ME-180 TRADD KO (lane 4). TRADD was detected at ~ 32 kDa using Anti- TRADD Rabbit Polyclonal Antibody (Product # <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/TRADD-Antibody-Polyclonal\/PA5-17465\">PA5-17465<\/a>, 1:1000 dilution). Loss of signal in CRISPR mediated knockout (KO) confirms antibody specificity.<\/p>\n<p style=\"text-align: left\">Western blot analysis of IKK\u03b1 (Fig. 1b) was performed using whole cell extracts of ME-180 CAS9 Control (lane 1), ME-180 CAS9 Scrambled (lane 2), ME-180 TNFR1 KO (lane 3), ME-180 TRADD KO (lane 4) and ME-180 IKK\u03b1 KO (lane 5). IKK\u03b1 was detected at ~ 80 kDa using Anti-IKK alpha Rabbit Polyclonal Antibody (Product # <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-Polyclonal\/PA5-17803\">PA5-17803<\/a>, 1:1000 dilution). Loss of signal in CRISPR mediated knockout (KO) confirms antibody\u00a0specificity.<\/p>\n<p style=\"text-align: left\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-12068 alignnone\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig2.jpg\" alt=\"Western blot analysis of TRADD \" width=\"598\" height=\"220\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig2.jpg 598w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig2-300x110.jpg 300w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/p>\n<p>CRISPR mediated knock out of NF-\u03baBp65 and NF-\u03baBp50 were also performed to address specificity of antibodies against respective unmodified proteins (Fig. 3 and Fig. 4).<\/p>\n<p><strong>Figure 3<\/strong><\/p>\n<p>Western blot analysis of NFkB p65 was performed using whole cell extracts of HeLa control (lane 1), HeLa NFkB p65 knockout (lane 2). NFkB p65 was detected at 65 kDa using NFkB p65 mouse monoclonal antibody (Product # <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-2A12A7-Monoclonal\/33-9900\">33-9900<\/a>, 1 \u00b5g\/mL). Loss of signal in CRISPR mediated knockout (KO) confirms that antibody is specific to NFkB p65.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/tnfr20fig3.jpg\" alt=\"Western blot analysis of NFkB p65 \" width=\"635\" height=\"481\" \/><\/p>\n<p><strong>Figure 4<\/strong><\/p>\n<p>Western blot analysis of NFkB p50 was performed using whole cell extracts of HeLa control (lane 1), HeLa NFkB p50 knockout (lane 2). NFkB p50 was detected at 105\/50 kDa using Anti-NFkB p50 Monoclonal Antibody (<a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-5D10-Monoclonal\/MA5-15860\">Product # MA5-15860<\/a>, 1:1000 dilution). Loss of signal in CRISPR mediated knockout (KO) confirms that antibody is specific to NFkB p50.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/tnfr20fig4.jpg\" alt=\"Western blot analysis of NFkB p50\" width=\"635\" height=\"439\" \/><\/p>\n<p><strong>How is CRISPR-CAS9 used to assess the specificity of antibodies against downstream effectors in the pathway?<\/strong><\/p>\n<p>CRISPR-Cas9 is a powerful tool to study pathway dynamics and signaling cascades. Specificity of antibodies against activated downstream targets can be determined by knocking out key upstream proteins in a pathway. Treatment of ME-180 cells with TNF\u03b1 results in recruitment of TRADD, which further leads to the activation of all downstream targets. NF-\u03baB is released and translocates to the nucleus and p38 is phosphorylated. In contrast, when upstream mediators like TNFR1, TRADD or IKK\u03b1 are knocked out, the activation cascade is blocked, even when treated with TNF-alpha. Figure 5 highlights the effect of knocking out TNFR1, TRADD or IKK-alpha on the nuclear translocation of NF-\u03baB. Downstream events like phosphorylation is arrested due to knock out of the upstream protein, like TRADD. This is shown in figure 6 where there is a loss of phosphorylation of p38 in TRADD knock-out ME-180 cells when compared to control cells upon induction with TNF-alpha.<\/p>\n<p><strong>Figure 5<\/strong><\/p>\n<p>Specificity of anti-NF-\u03baB p65 (Product # <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-4-2HCLC-Oligoclonal\/710048\">710048<\/a>) was demonstrated using CRISPR-Cas9 based TNFR1, TRADD and IKK alpha knockout (KO) cell lines. TNFalpha induced nuclear translocation of NF-\u03baB, a downstream target in the TNFR1, TRADD and IKK alpha was observed in control cell line (panels a,e) and not in the TNFR1, TRADD and IKK alpha knockout cell lines (panels b-d; f-h). Immunofluorescence analysis of NFkB p65 was done on 70% confluent log phase ME-180 Cas9 cells. The cells were either mock treated or treated with TNF-alpha (50 ng\/mL for 20 min). The cells were subsequently labeled with NFkB p65 (Green) Rabbit Oligoclonal Antibody (<a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-4-2HCLC-Oligoclonal\/710048\">710048<\/a>) at 1\u00b5g\/mL in 0.1% BSA. Nuclei (Blue) were stained with SlowFade\u00ae Gold Antifade Mountant DAPI (<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/S36938?SID=srch-hj-s36938\">S36938<\/a>). F-actin (Red) was stained with Rhodamine Phalloidin (Product # <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/R415?SID=srch-hj-r415\">R415<\/a>, 1:300). TNF alpha induced nuclear translocation of NFkB, a downstream target in the TNFR1, TRADD and IKK alpha was observed in control cell line (panels a,e) and not in the TNFR1, TRADD and IKK alpha knockout (KO) cell lines (panels b-d; f-h). The images were captured at 40X magnification.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/tnfr20fig5.jpg\" alt=\"Specificity of anti-NF-\u03baB p65 \" width=\"882\" height=\"463\" \/><\/p>\n<p><strong>Figure 6<\/strong><\/p>\n<p>Western blot analysis of phosphorylation of p38 \u00a0was performed with whole cell extracts of ME-180 CAS9 Control (lane1), ME-180 CAS9 Control treated with TNF\u03b1 (50ng\/mL for 20mins) (Lane 2), ME-180 TRADD KO (Lane 3) and ME-180 TRADD KO treated with TNF\u03b1 (50ng\/mL for 20mins) (Lane 4). Phospho p38 was detected at ~ 38 kDa using Phospho-p38 MAPK alpha (Thr180, Tyr182) Monoclonal Antibody (F.52.8) (<a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-p38-MAPK-alpha-Thr180-Tyr182-Antibody-clone-F-52-8-Monoclonal\/MA5-15177\">MA5-15177<\/a>). Upon induction with TNF\u03b1, phosphorylation of the downstream targets of TRADD (p38) was observed in control cell line lanes (1,2) and not in the TRADD knockout cell lines lanes (3,4).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12070\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig6-182x300.jpg\" alt=\"Western blot analysis of phosphorylation of p38 \" width=\"303\" height=\"500\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig6-182x300.jpg 182w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Fig6.jpg 479w\" sizes=\"auto, (max-width: 303px) 100vw, 303px\" \/><\/p>\n<p><strong>CRISPR-validated Invitrogen antibodies recommended for the TNFR pathway<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>SKU<\/strong><\/td>\n<td><strong>Target Name<\/strong><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-Polyclonal\/51-0500\">51-0500<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-Polyclonal\/51-0500\">NFkB p65 Polyclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-4-2HCLC-Oligoclonal\/710048\">710048<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-4-2HCLC-Oligoclonal\/710048\">NFkB p65 Antibody (4-2HCLC), ABfinity\u2122 Rabbit Oligoclonal<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-IKK-alpha-beta-Ser176-Ser180-Antibody-clone-7HCLC-Oligoclonal\/710676\">710676<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-IKK-alpha-beta-Ser176-Ser180-Antibody-clone-7HCLC-Oligoclonal\/710676\">Phospho-IKK alpha\/beta (Ser176, Ser180) Antibody (7HCLC), ABfinity\u2122 Rabbit Oligoclonal<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-IKK-alpha-beta-Ser176-Ser180-Antibody-clone-7H17L17-Monoclonal\/701643\">701643<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-IKK-alpha-beta-Ser176-Ser180-Antibody-clone-7H17L17-Monoclonal\/701643\">Phospho-IKK alpha\/beta (Ser176, Ser180) Antibody (7H17L17), ABfinity\u2122 Rabbit Monoclonal<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-Polyclonal\/PA5-17803\">PA5-17803<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-Polyclonal\/PA5-17803\">IKK alpha Polyclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-clone-3A11-Monoclonal\/LF-MA0161\">LF-MA0161<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-clone-3A11-Monoclonal\/LF-MA0161\">IKK alpha Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-clone-14A231-Monoclonal\/MA5-16157\">MA5-16157<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/IKK-alpha-Antibody-clone-14A231-Monoclonal\/MA5-16157\">IKK alpha Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/TRADD-Antibody-Polyclonal\/PA5-34807\">PA5-34807<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/TRADD-Antibody-Polyclonal\/PA5-34807\">TRADD Polyclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/TRADD-Antibody-Polyclonal\/PA5-17465\">PA5-17465<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/TRADD-Antibody-Polyclonal\/PA5-17465\">TRADD Polyclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-2A12A7-Monoclonal\/33-9900\">33-9900<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p65-Antibody-clone-2A12A7-Monoclonal\/33-9900\">NFkB p65 Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-p38-MAPK-alpha-Thr180-Tyr182-Antibody-Polyclonal\/36-8500\">36-8500<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-p38-MAPK-alpha-Thr180-Tyr182-Antibody-Polyclonal\/36-8500\">Phospho-p38 MAPK alpha (Thr180, Tyr182) Polyclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-p38-MAPK-alpha-Thr180-Tyr182-Antibody-clone-F-52-8-Monoclonal\/MA5-15177\">MA5-15177<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Phospho-p38-MAPK-alpha-Thr180-Tyr182-Antibody-clone-F-52-8-Monoclonal\/MA5-15177\">Phospho-p38 MAPK alpha (Thr180, Tyr182) Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-2J10D7-Monoclonal\/MA1-41314\">MA1-41314<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-2J10D7-Monoclonal\/MA1-41314\">NFkB p50 Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-5D10-Monoclonal\/MA5-15860\">MA5-15860<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-5D10-Monoclonal\/MA5-15860\">NFkB p50 Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-5D10D11-Monoclonal\/MA5-15870\">MA5-15870<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/NFkB-p50-Antibody-clone-5D10D11-Monoclonal\/MA5-15870\">NFkB p50 Monoclonal Antibody<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*The use or any variation of the word \u201cvalidation\u201d refers only to research use antibodies that were subject to functional testing to confirm that the antibody can be used with the research techniques indicated. It does not ensure that the product(s) was validated for clinical or diagnostic uses.<\/p>\n<p>&nbsp;<\/p>\n<p>For Research Use Only. Not for Use in Diagnostic Procedures.<\/p>\n<p><!-- BEGIN KAPOST ANALYTICS CODE --><\/p>\n<p><!-- var _kaq = _kaq || []; _kaq.push([2, \"5c759d30f17a3100b2000918\", \"5674227b963491538f00011d\"]); (function(){ var ka = document.createElement(\"script\"); ka.async=true; ka.id=\"ka_tracker\"; ka.src = (document.location.protocol == \"https:\" ? \"https\" : \"http\") + \":\/\/analytics.kapost.com\/ka.js\"; var s = document.getElementsByTagName(\"script\")[0]; s.parentNode.insertBefore(ka, s); })(); \/\/--><\/p>\n<p><!-- END KAPOST ANALYTICS CODE --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>By Parveen Dawood and Sarvani Emani Learn more about the TNFR pathway and CRISPR-validated* Invitrogen antibodies. What is the significance of the TNFR pathway and what are the key proteins? The TNFR pathway is one of the most studied oncogenic and apoptotic pathways. Tumor necrosis factor-alpha (TNF-alpha) is a proinflammatory cytokine which plays a key<\/p>\n","protected":false},"author":120,"featured_media":12074,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[54,172],"tags":[126,159],"division":[],"class_list":{"0":"post-12062","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cancer-research","8":"category-general","9":"tag-crispr-cas9","10":"tag-immunology","11":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Let\u2019s get \u2018specific\u2019 about the TNFR pathway!<\/title>\n<meta name=\"description\" content=\"The TNFR pathway and CRISPR-validated* Invitrogen antibodies\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!\" \/>\n<meta property=\"og:description\" content=\"The TNFR pathway and CRISPR-validated* Invitrogen antibodies\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-02-26T22:34:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-03-11T18:45:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"563\" \/>\n\t<meta property=\"og:image:height\" content=\"588\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!\",\"datePublished\":\"2019-02-26T22:34:33+00:00\",\"dateModified\":\"2019-03-11T18:45:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/\"},\"wordCount\":1232,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/TNFR-Header4.jpg\",\"keywords\":[\"CRISPR-Cas9\",\"immunology\"],\"articleSection\":[\"Cancer Research\",\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/\",\"name\":\"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/TNFR-Header4.jpg\",\"datePublished\":\"2019-02-26T22:34:33+00:00\",\"dateModified\":\"2019-03-11T18:45:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"The TNFR pathway and CRISPR-validated* Invitrogen antibodies\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/TNFR-Header4.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/02\\\/TNFR-Header4.jpg\",\"width\":563,\"height\":588},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/lets-get-specific-about-the-tnfr-pathway\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!","description":"The TNFR pathway and CRISPR-validated* Invitrogen antibodies","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/","og_locale":"en_US","og_type":"article","og_title":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!","og_description":"The TNFR pathway and CRISPR-validated* Invitrogen antibodies","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-02-26T22:34:33+00:00","article_modified_time":"2019-03-11T18:45:34+00:00","og_image":[{"width":563,"height":588,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!","datePublished":"2019-02-26T22:34:33+00:00","dateModified":"2019-03-11T18:45:34+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/"},"wordCount":1232,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","keywords":["CRISPR-Cas9","immunology"],"articleSection":["Cancer Research","General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/","name":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","datePublished":"2019-02-26T22:34:33+00:00","dateModified":"2019-03-11T18:45:34+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"The TNFR pathway and CRISPR-validated* Invitrogen antibodies","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","width":563,"height":588},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/lets-get-specific-about-the-tnfr-pathway\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Let\u2019s get \u2018specific\u2019 about the TNFR pathway!"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":54,"label":"Cancer Research"},{"value":172,"label":"General"}],"post_tag":[{"value":126,"label":"CRISPR-Cas9"},{"value":159,"label":"immunology"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg",563,588,false],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":56,"category_info":[{"term_id":54,"name":"Cancer Research","slug":"cancer-research","term_group":0,"term_taxonomy_id":54,"taxonomy":"category","description":"","parent":0,"count":143,"filter":"raw","meta":[],"cat_ID":54,"category_count":143,"category_description":"","cat_name":"Cancer Research","category_nicename":"cancer-research","category_parent":0},{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":161,"filter":"raw","meta":[],"cat_ID":172,"category_count":161,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":126,"name":"CRISPR-Cas9","slug":"crispr-cas9","term_group":0,"term_taxonomy_id":126,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":159,"name":"immunology","slug":"immunology","term_group":0,"term_taxonomy_id":159,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19235,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/crispr-digital-pcr-gene-editing-workflow\/","url_meta":{"origin":12062,"position":0},"title":"Revolutionizing Gene Editing with CRISPR and Digital PCR &#8211; A Conversation with Dr. Dustin Rubinstein","author":"Behind The Bench Staff","date":"November 11, 2025","format":false,"excerpt":"In a recent Absolute Gene-ius podcast episode titled \u201cCRISPR, dPCR, and pigs - a cut above the rest\u201d, Dr. Dustin Rubinstein, Director of the Advanced Genome Editing Laboratory at the University of Wisconsin-Madison, shared his insights on how CRISPR and digital PCR (dPCR) are revolutionizing gene editing workflows. This Q&A\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/S3-E1-Header-Image-1_Jordan-Ruggieri-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19447,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/philadelphia-chromosome-like-all-digital-pcr\/","url_meta":{"origin":12062,"position":1},"title":"Unlocking Cancer\u2019s Genetic Secrets with Digital PCR","author":"Behind The Bench Staff","date":"February 27, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, we explore how digital PCR (dPCR) is transforming leukemia research with Valeria Rangel, a PhD candidate at the University of California, Irvine. Her work focuses on Philadelphia chromosome-like (Ph-like) B-cell acute lymphoblastic leukemia (ALL), a rare, aggressive subtype that disproportionately affects Hispanic populations. By\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/RANGEL-headshot-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19579,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/liquid-biopsy-cancer-research-ngs-pcr\/","url_meta":{"origin":12062,"position":2},"title":"From Discovery to Monitoring: How Sequencing and PCR Work Together in Oncology Research","author":"Behind The Bench Staff","date":"March 24, 2026","format":false,"excerpt":"Scientific, joins the Absolute Gene-ius podcast to discuss how molecular technologies are advancing precision oncology research. With experience spanning clinical laboratory research, digital PCR research applications, and next-generation sequencing (NGS), Dr. Sollweck shares how scientists are addressing critical unmet needs in cancer research. From liquid biopsy research strategies to minimal\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Sollweck-headshot-200x250_Jordan-Ruggieri.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":12062,"position":3},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19345,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/precision-oncology-diagnostics\/","url_meta":{"origin":12062,"position":4},"title":"The Expanding Role of Molecular Diagnostics in Precision Oncology","author":"Behind The Bench Staff","date":"January 13, 2026","format":false,"excerpt":"https:\/\/www.youtube.com\/watch?v=F6FfHIizJBY For Dr. Harald Bartsch, a clinical pathologist in southern Bavaria, molecular diagnostic tools have become an indispensable part of his arsenal. \u201cI believe molecular diagnostics play a crucial role in modern oncology, and I see this as the direction everything is headed,\u201d says Dr. Bartsch. While immunohistochemistry remains central\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Clinical Pathologist in a Molecular Diagnostics Laboratory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/Bartsch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20019,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/qpcr-dpcr-ngs-cancer-research\/","url_meta":{"origin":12062,"position":5},"title":"From tumor heterogeneity to low-frequency variants: How qPCR, dPCR, and NGS work together in cancer research","author":"Ashleigh Barlow","date":"September 26, 2026","format":false,"excerpt":"Dr. Javier Hernandez Losa explains how combining broad genomic profiling with targeted, sensitive confirmation can help researchers address some of cancer biology\u2019s most difficult analytical challenges. A Q&A with Dr. Javier Hernandez Losa, Director of the Molecular Biology Laboratory, Department of Pathology, Hospital Universitario Vall d\u2019Hebron, Barcelona Cancer research increasingly\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Dr. Javier Hernandez Losa, Director of the Molecular Biology Laboratory at Hospital Universitario Vall d'Hebron in Barcelona.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Picture133.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Picture133.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Picture133.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Picture133.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/09\/Picture133.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/02\/TNFR-Header4.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=12062"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12062\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/12074"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=12062"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=12062"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=12062"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=12062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}