{"id":12078,"date":"2019-03-05T18:38:46","date_gmt":"2019-03-05T18:38:46","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=12078"},"modified":"2019-03-20T18:23:23","modified_gmt":"2019-03-20T18:23:23","slug":"senescence","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/","title":{"rendered":"Senescence: What is it? What\u2019s a new way to study it?"},"content":{"rendered":"<p>Have you heard the term <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10840?icid=BID_FCREG_PJT3109_senescence\" target=\"_blank\" rel=\"noopener noreferrer\">senescence<\/a> but don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.<\/p>\n<p>Scott Clarke, B.S., a Senior Staff Scientist, and Taryn Jackson, Ph.D., are R&amp;D scientists at Thermo Fisher Scientific who work on the development of fluorescent reagents for cell and tissue staining. Along with a team of other cell biologists, they have developed a novel fluorogenic \u03b2-galactosidase (\u03b2-gal) substrate for the detection of senescent cells by flow cytometry and fluorescence imaging. They sat down and spoke to us about how the new Invitrogen\u2122 CellEvent\u2122 Senescence Green Probe detects <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10840?icid=BID_FCREG_PJT3109_cellular\" target=\"_blank\" rel=\"noopener noreferrer\">cellular senescence<\/a> and share information on the probe\u2019s benefits and guidelines for its use in multiplex flow cytometry and imaging experiments.<\/p>\n<h2>What is senescence?<\/h2>\n<p>Senescent cells are cells that have stopped dividing due to telomere shortening, stress, or damage, but remain metabolically active.<sup>1-4<\/sup><\/p>\n<h2>How does senescence occur? What are characteristics of senescent cells?<\/h2>\n<p>Normal cells are known to have a limited replicative lifespan commonly known as the Hayflick limit.<sup>5 <\/sup>After normal cells enter cell cycle arrest, they enter a senescent phase where they remain metabolically active without undergoing cell death processes. These senescent cells adopt a specific phenotypic state that includes the appearance of multinucleated cells, increased vacuolization, expression of pH-dependent \u03b2-gal, and morphological changes where cells become enlarged and extended.<sup>6,7<\/sup> This change in cell state is accompanied by an increase in expression (\u03b2-gal), making any substrate for this enzyme an ideal marker to identify senescent cells when selectively labelled.<\/p>\n<h2>How is senescence detected?<\/h2>\n<p>\u03b2-gal activation is commonly used as a biomarker for senescent cells. Although \u03b2-gal activity is considered a hallmark of senescence, it does not cause the phenomena. Rather, it has been shown that there is an increase in enzymatic activity as the cells enter a senescent state. This hydrolase enzyme resides in lysosomes and converts \u03b2-galactosides into monosaccharides under acidic conditions. The activity is optimal under lysosomal pH 4, but conventional assays measure at pH 6. It has been shown that normalized \u03b2-gal activity is twice as high in senescent cells as in pre-senescent cells, regardless of the pH value used for testing.<sup>8<\/sup><\/p>\n<h2>What assays are available to detect senescence?<\/h2>\n<p>There are several assays used by researchers for detecting senescence.<sup>9<\/sup> The colorimetric substrate for \u03b2-gal, 5-bromo-4-chloro-3-indolyl-\u03b2-D-galactopyranoside, known as x-gal has long been used to detect metabolic activity in cells <em>in vitro<\/em>. On hydrolysis by \u03b2-gal, x-gal is converted into a blue precipitate that can be detected using microscopy. While the x-gal assay is viewed as the \u201cgold standard\u201d method, it is limited in that it is a colourimetric assay.\u00a0 C12FDG is a fluorescent alternative to x-gal.\u00a0 If also functions as a \u03b2-gal substrate, but has the drawback of leaking out of the cell within a short period of time.\u00a0 In flow cytometry, many researchers prefer to rely on a combination of antibody markers such as p16<sup>ARF<\/sup> and p21.\u00a0 An alternative is CellEvent Senescence Green Reagent (Figure 1).\u00a0 It offers a sensitive, fluorescent substrate for \u03b2-gal that can be used for the detection of senescent cells in flow cytometry assays and imaging applications.\u00a0 It offers the advantage of not only being a fluorescent substrate for \u03b2-gal, but does not leak out of cells with time due to its ability to covalently bind to intracellular proteins.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12243 size-large\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/03\/Figure-1_CORRECTED_15-March-2019-1024x420.jpg\" alt=\"Senescent and non-senescent cells treated with CellEvent Senescence Green Probe or X-gal. \" width=\"1024\" height=\"420\" \/><\/p>\n<p><strong>Figure 1. <\/strong><strong>Senescent and non-senescent cells treated with CellEvent Senescence Green Probe or X-gal. <\/strong>T47D human epithelial cells were untreated (day 0) or treated with 5 \u00b5M palbociclib every other day for 15 days to induce senescence (days 2-14) Cells were stained with the CellEvent Senescence Green Probe for 90 minutes or with X-gal overnight. Stained cells were imaged using the Thermo Scientific CellInsight CX5 High Content Screening Platform using the FITC filter for CellEvent Senescence Green or brightfield for colorimetric X-gal detection.<\/p>\n<h2>What type of research can utilize a fluorescent senescence reagent?<\/h2>\n<p>Identifying cellular senescence is of growing interest in cancer treatment, aging, developmental biology, and inflammatory disorders such as arthritis. Senescent cells have been implicated in contributing to age-related diseases such as Parkinson\u2019s and diabetes, along with cancer resistance and metastasis. Senolytic compounds that selectively target senescent cells may have therapeutic implications in a variety of age-related disorders and cancer treatment. Because the <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10840?icid=BID_FCREG_PJT3109_CellEvent\">CellEvent Senescence Green Flow Cytometry Kit<\/a> can selectively identify senescent cells and is fixable and multiplexable, it can be used in research studies on the role of senescent cells in aging and age-related disorders, cellular stresses such as inflammation, and cancer treatment.<\/p>\n<h2>Tell me more about the CellEvent Senescence Green Assay.<\/h2>\n<p>The Invitrogen\u2122 CellEvent Senescence Green Reagent is a fluorogenic substrate for senescence-associated \u03b2-gal detection (Figures 2 and 3). It contains two galactoside moieties, making it specific to \u03b2-gal. \u00a0Upon recognition and enzymatic cleavage by \u03b2-gal, the CellEvent Senescence Green Probe produces a reactive, fluorescent product that covalently binds to cellular components containing thiols, amines and hydroxyl groups and emits a fluorogenic signal. This covalent attachment allows for cellular retention and multiplexing with intracellular markers and other fixable fluorescent probes in flow cytometry. Other \u03b2-gal substrates, such as C12FDG, have been used to detect senescent cells but this reagent does not covalently react, so it leaks out of cells and cannot be combined with fixation, permeabilization, and intracellular staining protocols.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20cycling20senescent20histogram.png\" alt=\"senescent and non-senescent cells treated with CellEvent Senescence Green Flow Cytometry Assay Kit\" width=\"300\" height=\"300\" \/><\/p>\n<p><strong>Figure 2. Histogram of senescent and non-senescent cells treated with CellEvent Senescence Green Flow Cytometry Assay Kit<\/strong>. T47D human epithelial cells were left untreated (cycling\/control; grey histogram peak) or treated with 5 uM palbociclib for 15 days to induce senescence (red histogram peak) through cyclin D checkpoint blockade. The median fluorescence intensity of the senescent cell peak as measured by staining with <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10840\">Invitrogen\u2122 CellEvent Senescence Green Reagent<\/a>, is approximately 1 log higher than non-senescent cells.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg\" alt=\"Cellevent Senescence Green dot plots\" width=\"600\" height=\"655\" \/><\/p>\n<p><strong>Figure 3.<\/strong> <strong>Cyclin A2 and B1 expression decreases with the onset of senescence<\/strong><strong>. <\/strong>Senescence was induced in T47D, human epithelial cells by treating with 5 uM palbociclib in media every other day for 15 days, and were stained with CellEvent Senescence Green Reagent following the protocol. Cycling T47D cells progress through the various cell cycle stages as indicated by the expression of cyclin A2 and B1. A lack of expression of the cyclins (B) demonstrates cell cycle arrest in senescent cells.<\/p>\n<h2>If incorporating the CellEvent Senescence Green reagent into a flow cytometry panel, what other markers or fluorescent reagents would be recommended for use and why?<\/h2>\n<p>As a multi-faceted process, senescence is implicated in many biological functions and diseases.\u00a0 Studying the contribution or impact that other markers have on senescent cells will provide insights into the mechanisms involved (see Table 1).<\/p>\n<p><strong>Table 1. A non-exhaustive list of markers for studying senescence<\/strong><strong>-associated mechanisms and proteins<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12083 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/9\/2019\/03\/Figure1.jpg\" alt=\"non-exhaustive list of markers for studying senescence\" width=\"590\" height=\"1069\" srcset=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/Figure1.jpg 590w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/Figure1-166x300.jpg 166w, https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/Figure1-565x1024.jpg 565w\" sizes=\"auto, (max-width: 590px) 100vw, 590px\" \/><\/p>\n<p>Other non-antibody based fluorescent reagents measuring various cellular features of senescence could also be useful to include in panels such as the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometry-assays-reagents\/cell-proliferation-flow-cytometry\/edu-superior-brdu-alternative-cell-proliferation.html\">Invitrogen\u2122 Click-iT EdU Cell Proliferation Kits<\/a> to confirm the lack of proliferation of senescent cells, the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometry-assays-reagents\/cell-cycle-assays-flow-cytometry\/cell-cycle-analysis-fixed-cells.html\">Invitrogen\u2122 FxCycle stains<\/a> to detect cell cycle arrest, <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10491\">Invitrogen\u2122 CellROX Deep Red Flow Cytometry Assay Kit<\/a> to monitor the increase in reactive oxygen species, and <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/M22426\">Invitrogen\u2122 MitoTracker Deep Red reagent<\/a> to monitor mitochondrial changes associated with cellular senescence (see Table 2).<\/p>\n<p><strong>Table 2. A list of cell health flow cytometry reagents that could be multiplexed with CellEvent Senescence Green Reagent.<\/strong><\/p>\n<p>Any tips and tricks you recommend for using the CellEvent Senescence Green reagent in flow cytometry panels?<\/p>\n<ul>\n<li>When combining CellEvent Senescence Green with intracellular staining, cells should be stained with the CellEvent Senescence Green Probe after fixation but before permeabilization since permeabilizing the cells prior to staining can affect the \u03b2-gal enzyme and result in loss of the CellEvent Senescence Green signal. Once cells have been stained with the CellEvent Senescence Green Probe, the cleaved substrate covalently reacts so that cells can be permeabilized with detergents such as Triton X-100 or saponin followed by staining for intracellular targets.<\/li>\n<li>When incubating with the CellEvent Senescence Green Probe, cells should be kept in a 37\u00b0C incubator with no CO<sub>2<\/sub> so that the reaction buffer remains at pH 6, which is the optimal pH to detect SA-\u03b2-gal. Because the level of SA-\u03b2-gal can vary in different cell types and samples, the substrate concentration and incubation time should be optimized to allow for optimal discrimination between senescent and cycling cells.<\/li>\n<li>Because senescent cells are typically larger than cycling cells, forward scatter and side scatter parameters can be used as an advantage to separate the populations in senescent cells with weakly upregulated SA-\u03b2-gal expression.<\/li>\n<li>Suggested controls are unstained cells for autofluorescence and normal cycling cells of the same cell type as the senescent cells for a negative control. As a positive control, senescence can be experimentally induced in cells through a variety of methods and treatment with agents that cause DNA damage, cellular stress, or cell cycle arrest.<sup><sup>5,6, 7<\/sup><\/sup><\/li>\n<\/ul>\n<p>Does the CellEvent Senescence Green Reagent work in other applications?CellEvent Senescence Green can also be used for the detection of cellular senescence in fixed cells for imaging applications. This reagent provides a fluorescent alternative to colorimetric X-gal staining that is the gold standard for detection of senescent cells in imaging, along with the added benefit of multiplexing with fluorescence immunostaining and other fixed cell reagents. The <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10850\">CellEvent Senescence Green Detection Kit<\/a> provides the CellEvent Senescence Green Reagent and Buffer optimized for imaging applications along with a protocol for staining senescent cells for detection using fluorescence microscopy or in high-content screening applications. It is important to note that SA-\u03b2-gal activity is destroyed in FFPE (formalin fixed paraffin embedded) tissue, but is active in cryopreserved tissue. Gentle formaldehyde fixation of cell cultures with 2% formaldehyde plus 0.2% glutaraldehyde for 10 minutes results in good retention of SA-\u03b2-gal activity for image based detection. <sup>11<\/sup>What key references should I review if I want to learn more about detecting senescence?<\/p>\n<ul>\n<li>Cellular senescence in aging and age-related disease: from mechanism to therapy. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26646499\">Nat Med. 2015;21(12):1424-35<\/a>.<\/li>\n<li>Aging, Cellular Senescence, and Cancer. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/23140366\">Annu Rev Physiol. 2013;75:685-705.<\/a><\/li>\n<li>Characterization of novel markers of senescence and their prognostic potential in cancer. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25412306\">Cell Death Dis. 2014;5:e1528<\/a>.<\/li>\n<li>Senolytics improve physical function and increase lifespan in old age.<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29988130\"> Nat Med. 2018;24(8):1246-1256.<\/a><\/li>\n<li>Techniques to Induce and Quantify Cellular Senescence<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/28518126\">. J Vis Exp. 2017;(123)<\/a>.<\/li>\n<li>The essence of senescence. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/21078816\">Genes Dev. 2010 Nov 15;24(22):2463-79<\/a>.<\/li>\n<li>Small molecule\u00a0compounds that induce cellular senescence.\u00a0<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27628712\">Aging Cell. 2016; 15:999-1017.<\/a><\/li>\n<li>Quantitative assay of senescence-associated beta-galactosidase activity in mammalian cell extracts.\u00a0<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/16004951\">Anal Biochem.\u00a02005;343:329\u2013334.<\/a><\/li>\n<li>A biomarker that identifies senescent human cells in culture and in aging skin in vivo.\u00a0<a href=\"https:\/\/www.pnas.org\/content\/pnas\/92\/20\/9363.full.pdf\">Proc. Natl. Acad. Sci. USA. 1995;92(20):9363-7<\/a>.<\/li>\n<li>Colorimetric detection of senescence-associated beta galactosidase.\u00a0<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3769963\/\">Methods Mol. Bio. 2013; 965: 143-156.<\/a><\/li>\n<li>Protocols to detect senescence-associated beta-galactosidase (SA-betagal) activity, a biomarker of senescent cells in culture and in vivo. <a href=\"http:\/\/www.telomer.com.tr\/wp-content\/uploads\/2015\/12\/Protocols-to-detect-senescence-associated-beta-galactosidase_Debacq-Chainiaux-et-al_Nature2009.pdf\">Nat Protoc. 2009;4(12):1798-806.<\/a><\/li>\n<\/ul>\n<p>Products availableInterested in learning about other products or reading about other topics for <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry.html?icid=BID_FCREG_PJT3109_flow\" target=\"_blank\" rel=\"noopener noreferrer\">flow cytometry<\/a>? Read more Behind the Bench blog posts for Flow Cytometry <a href=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/tag\/flow-cytometry\/?icid=fl-flowblog\">here<\/a>.<br \/>\nFor Research Use Only. Not for Use in Diagnostic Procedures.<\/p>\n<table>\n<tbody>\n<tr>\n<th><strong>\u00a0\u00a0Analysis<\/strong><\/th>\n<th><strong>\u00a0\u00a0Product<\/strong><\/th>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0DNA synthesis measurement<\/td>\n<td>\u00a0\u00a0<a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometry-assays-reagents\/cell-proliferation-flow-cytometry\/edu-superior-brdu-alternative-cell-proliferation.html\">Click-iT\u2122 EdU Cell Proliferation Flow Cytometry Kits<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0Dye dilution assay<\/td>\n<td>\u00a0\u00a0<a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometry-assays-reagents\/cell-proliferation-flow-cytometry\/improved-cfse-alternatives-cell-proliferation.html\">CellTrace\u2122 Cell Proliferation Kits<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0Fixed cell cycle assay<\/td>\n<td>\u00a0\u00a0<a href=\"http:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/cell-analysis\/flow-cytometry\/flow-cytometry-assays-reagents\/cell-cycle-assays-flow-cytometry.html\">FxCycle\u2122 stains<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0Oxidative stress assay<\/td>\n<td>\u00a0\u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/brands\/molecular-probes\/key-molecular-probes-products\/cellrox-reagents-kits-ros-detection.html\">CellROX\u2122 Flow Cytometry Kits<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u00a0\u00a0Mitochondrial localization<\/td>\n<td>\u00a0\u00a0<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/M22426\">Invitrogen\u2122 MitoTracker Deep Red reagent<\/a><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td><strong>Product<\/strong><\/td>\n<td><strong>Size<\/strong><\/td>\n<td><strong>Cat. No.<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">CellEvent\u2122 Senescence Green Flow Cytometry Assay Kit<\/p>\n<p>&nbsp;<\/td>\n<td>50 assays<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10840\">C10840<\/a><\/td>\n<\/tr>\n<tr>\n<td>200 assays<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10841\">C10841<\/a><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">CellEvent\u2122 Senescence Green Detection Kit<\/p>\n<p>&nbsp;<\/td>\n<td>25 mL<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10850\">C10850<\/a><\/td>\n<\/tr>\n<tr>\n<td>100 mL<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10851\">C10851<\/a><\/td>\n<\/tr>\n<\/tbody>\n<p><!-- BEGIN KAPOST ANALYTICS CODE --><!-- var _kaq = _kaq || []; _kaq.push([2, \"5c7732cdaba2d8007600002b\", \"5674227b963491538f00011d\"]); (function(){ var ka = document.createElement(\"script\"); ka.async=true; ka.id=\"ka_tracker\"; ka.src = (document.location.protocol == \"https:\" ? \"https\" : \"http\") + \":\/\/analytics.kapost.com\/ka.js\"; var s = document.getElementsByTagName(\"script\")[0]; s.parentNode.insertBefore(ka, s); })(); \/\/--><!-- END KAPOST ANALYTICS CODE --><\/table>\n","protected":false},"excerpt":{"rendered":"<p>Have you heard the term senescence but don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post. Scott Clarke, B.S., a Senior Staff Scientist, and Taryn Jackson, Ph.D., are R&amp;D scientists at Thermo Fisher Scientific who work on the development of fluorescent reagents for cell and<\/p>\n","protected":false},"author":286,"featured_media":12077,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[54,172,135],"tags":[210,159],"division":[],"class_list":["post-12078","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cancer-research","category-general","category-immunology","tag-flow-cytometry","tag-immunology","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Senescence: What is it? What\u2019s a new way to study it? - Behind the Bench<\/title>\n<meta name=\"description\" content=\"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Senescence: What is it? What\u2019s a new way to study it?\" \/>\n<meta property=\"og:description\" content=\"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-05T18:38:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-03-20T18:23:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1092\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Suzanne Buck, PhD\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Suzanne Buck, PhD\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/\"},\"author\":{\"name\":\"Suzanne Buck, PhD\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/aaee915b97933216d9589a5cb6361f66\"},\"headline\":\"Senescence: What is it? What\u2019s a new way to study it?\",\"datePublished\":\"2019-03-05T18:38:46+00:00\",\"dateModified\":\"2019-03-20T18:23:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/\"},\"wordCount\":1877,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/03\\\/cellevent20senescence20green20dot20plots.jpg\",\"keywords\":[\"Flow Cytometry\",\"immunology\"],\"articleSection\":[\"Cancer Research\",\"General\",\"Immunology\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/\",\"name\":\"Senescence: What is it? What\u2019s a new way to study it? - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/03\\\/cellevent20senescence20green20dot20plots.jpg\",\"datePublished\":\"2019-03-05T18:38:46+00:00\",\"dateModified\":\"2019-03-20T18:23:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/aaee915b97933216d9589a5cb6361f66\"},\"description\":\"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/03\\\/cellevent20senescence20green20dot20plots.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/03\\\/cellevent20senescence20green20dot20plots.jpg\",\"width\":1000,\"height\":1092,\"caption\":\"Cellevent Senescence Green dot plots\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/senescence\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Senescence: What is it? What\u2019s a new way to study it?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/aaee915b97933216d9589a5cb6361f66\",\"name\":\"Suzanne Buck, PhD\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g\",\"caption\":\"Suzanne Buck, PhD\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/suzannebuck\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Senescence: What is it? What\u2019s a new way to study it? - Behind the Bench","description":"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/","og_locale":"en_US","og_type":"article","og_title":"Senescence: What is it? What\u2019s a new way to study it?","og_description":"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-03-05T18:38:46+00:00","article_modified_time":"2019-03-20T18:23:23+00:00","og_image":[{"width":1000,"height":1092,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","type":"image\/jpeg"}],"author":"Suzanne Buck, PhD","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Suzanne Buck, PhD","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/"},"author":{"name":"Suzanne Buck, PhD","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/aaee915b97933216d9589a5cb6361f66"},"headline":"Senescence: What is it? What\u2019s a new way to study it?","datePublished":"2019-03-05T18:38:46+00:00","dateModified":"2019-03-20T18:23:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/"},"wordCount":1877,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","keywords":["Flow Cytometry","immunology"],"articleSection":["Cancer Research","General","Immunology"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/","name":"Senescence: What is it? What\u2019s a new way to study it? - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","datePublished":"2019-03-05T18:38:46+00:00","dateModified":"2019-03-20T18:23:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/aaee915b97933216d9589a5cb6361f66"},"description":"Have you heard the term senescence but you don\u2019t know what it is? Want to learn techniques to study it? Look no further. Read this blog post.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","width":1000,"height":1092,"caption":"Cellevent Senescence Green dot plots"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/senescence\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Senescence: What is it? What\u2019s a new way to study it?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/aaee915b97933216d9589a5cb6361f66","name":"Suzanne Buck, PhD","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d33ef5835a95d3ef07034350050c6a9500a7137fa2a76c7739d46aec7a675080?s=96&d=mm&r=g","caption":"Suzanne Buck, PhD"},"url":"https:\/\/admin.acceleratingscience.com\/author\/suzannebuck\/"}]}},"taxonomy_info":{"category":[{"value":54,"label":"Cancer Research"},{"value":172,"label":"General"},{"value":135,"label":"Immunology"}],"post_tag":[{"value":210,"label":"Flow Cytometry"},{"value":159,"label":"immunology"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots-938x1024.jpg",760,830,true],"author_info":{"display_name":"Suzanne Buck, PhD","author_link":"https:\/\/admin.acceleratingscience.com\/author\/suzannebuck\/"},"comment_info":3,"category_info":[{"term_id":54,"name":"Cancer Research","slug":"cancer-research","term_group":0,"term_taxonomy_id":54,"taxonomy":"category","description":"","parent":0,"count":143,"filter":"raw","meta":[],"cat_ID":54,"category_count":143,"category_description":"","cat_name":"Cancer Research","category_nicename":"cancer-research","category_parent":0},{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":162,"filter":"raw","meta":[],"cat_ID":172,"category_count":162,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":135,"name":"Immunology","slug":"immunology","term_group":0,"term_taxonomy_id":135,"taxonomy":"category","description":"","parent":0,"count":45,"filter":"raw","meta":[],"cat_ID":135,"category_count":45,"category_description":"","cat_name":"Immunology","category_nicename":"immunology","category_parent":0}],"tag_info":[{"term_id":210,"name":"Flow Cytometry","slug":"flow-cytometry","term_group":0,"term_taxonomy_id":210,"taxonomy":"post_tag","description":"","parent":0,"count":18,"filter":"raw","meta":[]},{"term_id":159,"name":"immunology","slug":"immunology","term_group":0,"term_taxonomy_id":159,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":12078,"position":0},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19857,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/mirna-biomarkers-type-1-diabetes\/","url_meta":{"origin":12078,"position":1},"title":"A pan-continental miRNA profiling study powered by TaqMan qPCR reveals potential new biomarkers for Type 1 Diabetes risk","author":"Ashleigh Barlow","date":"July 28, 2026","format":false,"excerpt":"In conversation with Professor Anandwardhan Hardikar Detecting type 1 diabetes (T1D) before major pancreatic damage occurs remains one of the biggest challenges in the field. By the time most patients are diagnosed, a large proportion of insulin-producing islet \u03b2-cells have already been lost. Traditional markers such as blood glucose or\u2026","rel":"","context":"In &quot;Complex Diseases&quot;","block_context":{"text":"Complex Diseases","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/complex-diseases\/"},"img":{"alt_text":"Professor Anandwardhan Hardikar discussing type 1 diabetes biomarker research in front of molecular biology data visualizations.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/hardikar_Lisa-Crawford.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19645,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/aav-viral-vector-analytics-cdmo\/","url_meta":{"origin":12078,"position":2},"title":"Almost a Virus: How CDMOs Enable Scalable Cell and Gene Therapy","author":"Behind The Bench Staff","date":"April 6, 2026","format":false,"excerpt":"In this episode of Absolute Gene-ius, Dr. Dan Mitchell, Senior Director of Analytical Development and Quality Control at Matica Biotechnology, explains how contract development and manufacturing organizations (CDMOs) support the advancement of cell and gene therapies. The discussion focuses on viral vector development, analytical strategies, and the technologies used to\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Headshot of a man with dark hair and a beard wearing a suit and tie against a neutral background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/DMitchell-Headshot-1_Jordan-Ruggieri.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19257,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cryopreservation-advancements-in-human-stem-cell-derived-neurons\/","url_meta":{"origin":12078,"position":3},"title":"Cryopreservation: Advancements in Human Stem Cell-Derived Neurons","author":"Behind The Bench Staff","date":"December 3, 2025","format":false,"excerpt":"The field of cryopreservation has seen advancements, particularly with the ability to preserve human stem cell-derived neurons. This progress holds great promise for research and therapeutic applications, helping to ensure the availability of high-quality neuronal cultures. What is Cryopreservation? Cryopreservation involves cooling cells to sub-zero temperatures to halt biological activity\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Illustration of active nerve cell synapses showing neural connections, related to cryopreservation research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/11\/active-nerve-cell-synapses.jpeg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19392,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/raw-material-considerations-for-cell-therapy-manufacturing\/","url_meta":{"origin":12078,"position":4},"title":"Raw material considerations for cell therapy manufacturing","author":"Behind The Bench Staff","date":"February 12, 2026","format":false,"excerpt":"In cell therapy manufacturing, the lack of definitive regulatory frameworks often makes the process of selecting and qualifying raw materials complex and unclear. In this blog post, we will explore the key considerations for choosing raw materials in cell therapy manufacturing and the importance of early selection in ensuring production\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19755,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/deterministic-programming-ipsc-disease-modeling\/","url_meta":{"origin":12078,"position":5},"title":"Finding the \u201cCheat Codes\u201d to Cell Identity: Deterministic Programming of iPSCs","author":"Ashleigh Barlow","date":"May 15, 2026","format":false,"excerpt":"Article Summary Fiona Connolly, formerly Platform Innovation and Automation Scientist at bit.bio, joins Absolute Gene-ius to discuss how deterministic programming is reshaping stem cell biology, disease modeling, and drug discovery. With a background spanning molecular biology, cell engineering, and automation, Fiona brings a unique perspective on how genetic \u201ccheat codes\u201d\u2026","rel":"","context":"In &quot;Gene Editing&quot;","block_context":{"text":"Gene Editing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/gene-editing\/"},"img":{"alt_text":"Portrait of Fiona Connolly speaking on stem cell engineering and deterministic programming technologies.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Connolly-LI-profile-pic-1_Jordan-Ruggieri-1.jpeg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/03\/cellevent20senescence20green20dot20plots.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12078","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/286"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=12078"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12078\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/12077"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=12078"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=12078"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=12078"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=12078"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}