{"id":12941,"date":"2019-11-04T21:51:05","date_gmt":"2019-11-04T21:51:05","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=12941"},"modified":"2020-03-17T15:24:40","modified_gmt":"2020-03-17T15:24:40","slug":"how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/","title":{"rendered":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing"},"content":{"rendered":"<p><span><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\" title=\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\" width=\"450\" height=\"253\" \/>Biopharmaceutical and pharmaceutical manufacturers must follow good manufacturing practices (GMP) and adhere to the FDA <\/span><a href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfcfr\/CFRSearch.cfm?CFRPart=11&amp;showFR=1&amp;subpartNode=21:1.0.1.1.8.1\"><span>21 CFR Part 11 requirements<\/span><\/a><span>. These requirements &ldquo;set forth the criteria under which the agency considers electronic records, electronic signatures, and handwritten signatures executed to electronic records to be trustworthy, reliable, and generally equivalent to paper records and handwritten signatures executed on paper.&rdquo;<\/span><\/p>\n<p><span>As part of their GMP and FDA requirements, biopharmaceutical and pharmaceutical manufacturers must identify and authenticate their raw materials.<span>&nbsp; <\/span>Compliance and efficiency are top concerns for raw materials managers, but thoroughly analyzing all incoming materials takes time and resources.<\/span><\/p>\n<p><span>Ionic salts are common materials used in pharmaceuticals.<span>&nbsp; <\/span>According to an article on <\/span><a href=\"https:\/\/www.drugs.com\/article\/pharmaceutical-salts.html#targetText=Over%2050%25%20of%20all%20drug,%2C%20sodium%2C%20or%20sulfate%20salts.&amp;targetText=Therefore%2C%20drugs%20are%20often%20chemically,bloodstream%2C%20and%20increase%20its%20effectiveness.\"><span><span>drugs.com<\/span><\/span><\/a><span>, &ldquo;over 50% of all drug molecules used in medicine exist as salts, most frequently as the hydrochloride, sodium, or sulfate salts. &hellip; drugs are often chemically made into their salt forms to enhance how the drug dissolves, boost its absorption into your bloodstream, and increase its effectiveness.&rdquo;<\/span><\/p>\n<p><span>The article goes on to say that additional advantages of drug salt formation include &ldquo;development of controlled-release dosage forms, improved stability to extend shelf life, targeted drug delivery in the gastrointestinal tract (stomach or intestine), improved taste, improved drug effectiveness, reduced pain on injection, ease of processing, and extended patent life.&rdquo;<\/span><\/p>\n<p><span>Biopharmaceutical manufacturers use salts in buffers throughout production &ndash; in upstream or cell culture production phase to help maintain cell culture media pH, downstream or purification phase to support optimal purification conditions and prevent aggregation, and during formulation and storage to promote protein product stability.<\/span><\/p>\n<p><span>The top five salts used include sodium chloride (NaCl), potassium chloride (KCl), magnesium chloride (MgCl2), calcium chloride (CaCl2) and sodium hydroxide (NaOH). <span>&nbsp;<\/span>These salts, of course, must be authenticated before being released into production. Pharmaceutical companies purchase these salts in large amounts and are required to test each container to meet the strict regulatory requirements. That&#8217;s a tedious and costly process when using standard wet chemistry lab or near-infrared (NIR) benchtop testing.<\/span><\/p>\n<p><span>There is technology, however, that puts laboratory-grade capabilities directly into the hands of raw material and quality control managers anywhere in the manufacturing plant. Pharmaceutical and biopharmaceutical manufacturers can verify the identity of ionic salts in the warehouse in a matter of seconds with <\/span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IONICX?icid=CAD_blog_LSM_2019Nov\"><span>portable X-ray fluorescence (XRF) analyzers<\/span><\/a><span>. <span>&nbsp;<\/span><\/span><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-analysis-information\/xrf-technology.html?icid=CAD_blog_LSM_2019Nov\"><span>XRF (X-ray fluorescence)<\/span><\/a><span> is a non-destructive analytical technique used to determine the elemental composition of materials. XRF analyzers determine the chemistry of a sample by measuring the fluorescent (or secondary) X-ray emitted from a sample when it is excited by a primary X-ray source. Each of the elements present in a sample produces a set of characteristic fluorescent X-rays (&#8220;a fingerprint&#8221;) that is unique for that specific element, which is why XRF spectroscopy is an excellent technology for qualitative and quantitative analysis of material composition.<\/span><\/p>\n<p><span>During the X-ray fluorescence process, the ionic salt is irradiated with high energy X-rays from a controlled X-ray tube, and then the following actions happen:<\/span><\/p>\n<ol>\n<li><span><span><span><\/span><\/span><\/span><span>When an atom in the sample is struck with an X-ray of sufficient energy (greater than the atom&rsquo;s K or L shell binding energy), an electron from one of the atom&rsquo;s inner orbital shells is dislodged.<\/span><\/li>\n<li><span><span><span><\/span><\/span><\/span><span>The atom regains stability, filling the vacancy left in the inner orbital shell with an electron from one of the atom&rsquo;s higher energy orbital shells. <\/span><\/li>\n<li><span><span><span><\/span><\/span><\/span><span>The electron drops to the lower energy state by releasing a fluorescent X-ray. <\/span><\/li>\n<li><span><span><span><\/span><\/span><\/span><span>The energy of this X-ray is equal to the specific difference in energy between two quantum states of the electron.<\/span><\/li>\n<\/ol>\n<p><span>The measurement of this energy is the basis of XRF analysis.<\/span><\/p>\n<p><span>Because it is non-destructive and needs minimal sample preparation, XRF analysis helps preserve production volume and ensure optimal throughput. The latest handheld <\/span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IONICX?icid=CAD_blog_LSM_2019Nov\"><span>XRF analyzers<\/span><\/a><span> are easy-to-use and comply with 21 CFR Part 11, offering user access control, audit trails, electronic signatures, and full synchronization capabilities for proper storage of all electronic records. Thus, they can reduce the time and cost of pharmaceutical materials testing while helping to maintain regulatory compliance and rigorous quality standards.<\/span><\/p>\n<p><em>Additional Resources:<span>&nbsp; <\/span><\/em><\/p>\n<ul>\n<li><span><span><span><span><\/span><\/span><\/span><\/span><span>Free ebook: A <\/span><a href=\"http:\/\/bit.ly\/2qPYWG0\"><span>Practical Guide to Improving Pharmaceutical and Biotech Manufacturing Processes and Production Methods<\/span><\/a><\/li>\n<li><span><span><span><\/span><\/span><\/span><span>Additional application notes, white papers, and other free resources are available in the <\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/improving-pharmaceutical-biotech-manufacturing-processes-production-methods.html?icid=CAD_blog_LSM_2019Nov\"><span>Improved Quality and Productivity for Pharma and Biotech Manufacturing<\/span><\/a><span> section of our website.<\/span><\/li>\n<\/ul>\n<p><em>&nbsp;<\/em><\/p>\n<p><em>&nbsp;<a href=\"http:\/\/bit.ly\/343qW8a\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/cad-lsm-e-signature-banner-600x125-1.jpg\" \/><\/a><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Biopharmaceutical and pharmaceutical manufacturers must follow good manufacturing practices (GMP) and adhere to the FDA 21 CFR Part 11 requirements. These requirements &ldquo;set forth the criteria under which the agency considers electronic records, electronic signatures, and handwritten signatures executed to electronic records to be trustworthy, reliable, and generally equivalent to paper records and handwritten signatures<\/p>\n","protected":false},"author":120,"featured_media":12981,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172,1087],"tags":[],"division":[],"class_list":{"0":"post-12941","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"category-pharmamfg","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Authenticate Ionic Salts in Pharmaceutical Manufacturing<\/title>\n<meta name=\"description\" content=\"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\" \/>\n<meta property=\"og:description\" content=\"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-11-04T21:51:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-17T15:24:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\",\"datePublished\":\"2019-11-04T21:51:05+00:00\",\"dateModified\":\"2020-03-17T15:24:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/\"},\"wordCount\":731,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/11\\\/bluebarrelswarehouse.jpg\",\"articleSection\":[\"General\",\"Pharma &amp; Biotech Manufacturing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/\",\"name\":\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/11\\\/bluebarrelswarehouse.jpg\",\"datePublished\":\"2019-11-04T21:51:05+00:00\",\"dateModified\":\"2020-03-17T15:24:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/11\\\/bluebarrelswarehouse.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2019\\\/11\\\/bluebarrelswarehouse.jpg\",\"width\":1920,\"height\":1080,\"caption\":\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing","description":"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/","og_locale":"en_US","og_type":"article","og_title":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing","og_description":"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-11-04T21:51:05+00:00","article_modified_time":"2020-03-17T15:24:40+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing","datePublished":"2019-11-04T21:51:05+00:00","dateModified":"2020-03-17T15:24:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/"},"wordCount":731,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","articleSection":["General","Pharma &amp; Biotech Manufacturing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/","name":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","datePublished":"2019-11-04T21:51:05+00:00","dateModified":"2020-03-17T15:24:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Pharmaceutical and biopharmaceutical manufacturers can verify identity of ionic salts in a matter of seconds with portable X-ray fluorescence (XRF) analyzers.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","width":1920,"height":1080,"caption":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-to-authenticate-ionic-salts-in-pharmaceutical-manufacturing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"How to Authenticate Ionic Salts in Pharmaceutical Manufacturing"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"},{"value":1087,"label":"Pharma &amp; Biotech Manufacturing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse-1024x576.jpg",760,428,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":0,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":172,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":1087,"name":"Pharma &amp; Biotech Manufacturing","slug":"pharmamfg","term_group":0,"term_taxonomy_id":1087,"taxonomy":"category","description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","parent":0,"count":60,"filter":"raw","meta":[],"cat_ID":1087,"category_count":60,"category_description":"Raw material identification through the pharmaceutical manufacturing process, to finished and packaged pharmaceutical product inspection","cat_name":"Pharma &amp; Biotech Manufacturing","category_nicename":"pharmamfg","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19585,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/advanced-verification-in-pharmaceutical-manufacturing-using-raman-spectroscopy\/","url_meta":{"origin":12941,"position":0},"title":"Advanced Verification in Pharmaceutical Manufacturing Using Raman Spectroscopy","author":"Marlene Gasdia-Cochrane","date":"April 21, 2026","format":false,"excerpt":"Article Summary Pharmaceutical manufacturing relies on strict quality control to ensure that every product released to the market is safe, effective, and compliant with regulatory standards. Analytical testing plays a critical role in verifying product identity, composition, and consistency. Among modern analytical techniques, Raman spectroscopy stands out as a powerful\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Syringes, injection bottles and tablets lying on the table. Close-up, indoors, view from above. Day light, studio photo. Healthcare concept","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1355152090.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19392,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/raw-material-considerations-for-cell-therapy-manufacturing\/","url_meta":{"origin":12941,"position":1},"title":"Raw material considerations for cell therapy manufacturing","author":"Behind The Bench Staff","date":"February 12, 2026","format":false,"excerpt":"In cell therapy manufacturing, the lack of definitive regulatory frameworks often makes the process of selecting and qualifying raw materials complex and unclear. In this blog post, we will explore the key considerations for choosing raw materials in cell therapy manufacturing and the importance of early selection in ensuring production\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/02\/Chapter-1-CTx-HB-BKG-2-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19353,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/manufacturing-strategy-in-pharma-scale-up-vs-scale-out-for-continuous-processes\/","url_meta":{"origin":12941,"position":2},"title":"Scale-Up vs. Scale-Out Strategies for Continuous Pharma Manufacturing","author":"Marlene Gasdia-Cochrane","date":"February 3, 2026","format":false,"excerpt":"As pharmaceutical pipelines evolve, manufacturing strategies are being tested in new ways. Drug candidates are more complex, development timelines are tighter, and expectations for quality and consistency continue to rise. Against this backdrop, one question comes up repeatedly for formulation and manufacturing teams:\u00a0should we scale up, or should we scale\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Sorting pharmaceutical capsules by a sorting machine on a production line","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/01\/iStock-1499814881.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19658,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/is-raman-spectroscopy-a-better-verification-method-in-pharmaceutical-manufacturing\/","url_meta":{"origin":12941,"position":3},"title":"Is Raman Spectroscopy a Better Verification Method in Pharmaceutical Manufacturing?","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Article Summary Verification testing is a critical step in pharmaceutical manufacturing, helping to ensure that every product released meets strict safety, quality, and regulatory standards. Verification helps ensure that products contain the correct active ingredients, meet concentration specifications, are free from contamination, and maintain structural and chemical integrity. This process\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Yellow pill and red check mark sitting on brown wood surface in front of abstract defocused background. Horizontal composition with selective focus and copy space. Front view. Drug approval concept.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19528,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/geometry-dependent-vs-parameter-driven-scale-up-in-pharmaceutical-manufacturing\/","url_meta":{"origin":12941,"position":4},"title":"Geometry-Dependent\u00a0vs\u00a0Parameter-Driven Scale Up\u00a0in Pharmaceutical Manufacturing\u00a0","author":"Marlene Gasdia-Cochrane","date":"March 31, 2026","format":false,"excerpt":"Overview\u00a0 Scale-up challenges in pharmaceutical manufacturing often stem from a fundamental distinction between geometry-dependent and parameter-driven systems. Processes that perform consistently at lab scale can shift unexpectedly at production scale. This is\u00a0often because the\u00a0governing physical logic was misunderstood. In geometry-dependent systems, equipment size directly alters heat transfer, mixing, dwell time,\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Macro Shot of Pink Pills During Production and Packing Process on Modern Pharmaceutical Factory. Medical Drug Manufacturing.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/iStock-1465073057_pillmfg.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19801,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/how-process-analytical-technology-enables-real-time-quality-control-in-pharmaceutical-manufacturing\/","url_meta":{"origin":12941,"position":5},"title":"How Process Analytical Technology Enables Real-time Quality Control in Pharmaceutical Manufacturing","author":"Marlene Gasdia-Cochrane","date":"July 7, 2026","format":false,"excerpt":"Article Summary Process analytical technology (PAT) is transforming pharmaceutical manufacturing by enabling real-time monitoring, process understanding, and quality control throughout the production lifecycle. By combining advanced analytics, in-line sensors, data modeling, and automation, PAT helps manufacturers identify critical process parameters (CPPs), improve product quality, reduce deviations, and support real-time release\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"test tubes and pharmaceutical products","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/iStock-1025828074_pat-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2019\/11\/bluebarrelswarehouse.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=12941"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/12941\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/12981"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=12941"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=12941"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=12941"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=12941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}