{"id":13136,"date":"2020-01-28T21:09:28","date_gmt":"2020-01-28T21:09:28","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/behindthebench\/?p=13136"},"modified":"2021-03-22T17:35:11","modified_gmt":"2021-03-22T17:35:11","slug":"improving-dna-profiling","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/","title":{"rendered":"Forensic DNA Profiling"},"content":{"rendered":"<h2><em>Improving The Sexual Assault Workflow Using Applied Biosystems Forensic Solutions<\/em><\/h2>\n<p>The Institute of Environmental Science and Research Limited \u00a0(ESR) supports the New Zealand Police in crime scene investigation, evidence collection and forensic DNA profiling. The DNA team has optimized their analysis workflow to gain the most probative information possible, especially from sexual assault evidence kits.<\/p>\n<p><iframe loading=\"lazy\" title=\"Applied Biosystems Quantifiler Trio, Yfiler Plus and Identifiler kits\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/Wn-tPdWOfhE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=Wn-tPdWOfhE\">In this video<\/a>, \u00a0Donna Foskin, senior scientist at ESR, describes how they process sexual assault kits. To start, the details of the case are taken into consideration along with the length of time that has passed since the assault occurred. Once the DNA has been extracted, the team uses <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/forensics\/human-identification\/forensic-dna-analysis\/dna-quantification-solutions.html\">Applied Biosystems Quantifiler Trio kit<\/a> to assess the quantity of DNA present along with the male-to-female ratio. This information then guides the decision to use autosomal STR testing with <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/forensics\/human-identification\/forensic-dna-analysis\/pcr-amplification-forensic-dna-profiling.html\">Applied Biosystems Identifiler PCR Amplification Kit<\/a> or Y-STR testing with Applied Biosystems <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/forensics\/human-identification\/forensic-dna-analysis\/pcr-amplification-forensic-dna-profiling\/y-str-analysis.html\">Yfiler Plus PCR Amplification Kit<\/a> or both.<\/p>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=Wn-tPdWOfhE\">Watch the video<\/a> to get all the details on how ESR has improved their processes to gain a better understanding of their more complex cases.<\/p>\n<p style=\"text-align: right\"><em>For Research Forensic or Paternity Use Only. Not for use in diagnostic procedures.\u00a0<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Improving The Sexual Assault Workflow Using Applied Biosystems Forensic Solutions The Institute of Environmental Science and Research Limited \u00a0(ESR) supports the New Zealand Police in crime scene investigation, evidence collection and forensic DNA profiling. The DNA team has optimized their analysis workflow to gain the most probative information possible, especially from sexual assault evidence kits.<\/p>\n","protected":false},"author":115,"featured_media":13138,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[71],"tags":[],"division":[],"class_list":["post-13136","post","type-post","status-publish","format-standard","has-post-thumbnail","category-forensics","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Forensic DNA Profiling - Behind the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Forensic DNA Profiling\" \/>\n<meta property=\"og:description\" content=\"Improving The Sexual Assault Workflow Using Applied Biosystems Forensic Solutions The Institute of Environmental Science and Research Limited \u00a0(ESR) supports the New Zealand Police in crime scene investigation, evidence collection and forensic DNA profiling. The DNA team has optimized their analysis workflow to gain the most probative information possible, especially from sexual assault evidence kits.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-28T21:09:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-22T17:35:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM-1024x533.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Angie Lackey\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Angie Lackey\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/\"},\"author\":{\"name\":\"Angie Lackey\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/dc5584f1865eb1f923344ca7444d78de\"},\"headline\":\"Forensic DNA Profiling\",\"datePublished\":\"2020-01-28T21:09:28+00:00\",\"dateModified\":\"2021-03-22T17:35:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/\"},\"wordCount\":200,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/01\\\/Screen-Shot-2020-01-28-at-1.08.26-PM.png\",\"articleSection\":[\"Forensics\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/\",\"name\":\"Forensic DNA Profiling - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/01\\\/Screen-Shot-2020-01-28-at-1.08.26-PM.png\",\"datePublished\":\"2020-01-28T21:09:28+00:00\",\"dateModified\":\"2021-03-22T17:35:11+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/dc5584f1865eb1f923344ca7444d78de\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/01\\\/Screen-Shot-2020-01-28-at-1.08.26-PM.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/01\\\/Screen-Shot-2020-01-28-at-1.08.26-PM.png\",\"width\":1908,\"height\":994},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/improving-dna-profiling\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Forensic DNA Profiling\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/dc5584f1865eb1f923344ca7444d78de\",\"name\":\"Angie Lackey\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g\",\"caption\":\"Angie Lackey\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/angie-lackey\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Forensic DNA Profiling - Behind the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/","og_locale":"en_US","og_type":"article","og_title":"Forensic DNA Profiling","og_description":"Improving The Sexual Assault Workflow Using Applied Biosystems Forensic Solutions The Institute of Environmental Science and Research Limited \u00a0(ESR) supports the New Zealand Police in crime scene investigation, evidence collection and forensic DNA profiling. The DNA team has optimized their analysis workflow to gain the most probative information possible, especially from sexual assault evidence kits.","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-01-28T21:09:28+00:00","article_modified_time":"2021-03-22T17:35:11+00:00","og_image":[{"width":1024,"height":533,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM-1024x533.png","type":"image\/png"}],"author":"Angie Lackey","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Angie Lackey","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/"},"author":{"name":"Angie Lackey","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/dc5584f1865eb1f923344ca7444d78de"},"headline":"Forensic DNA Profiling","datePublished":"2020-01-28T21:09:28+00:00","dateModified":"2021-03-22T17:35:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/"},"wordCount":200,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM.png","articleSection":["Forensics"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/","name":"Forensic DNA Profiling - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM.png","datePublished":"2020-01-28T21:09:28+00:00","dateModified":"2021-03-22T17:35:11+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/dc5584f1865eb1f923344ca7444d78de"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM.png","width":1908,"height":994},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/improving-dna-profiling\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Forensic DNA Profiling"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/dc5584f1865eb1f923344ca7444d78de","name":"Angie Lackey","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6611a87dbdad21a931d163d6dfd3f222f03f1a321c43c9f07bfdc93901db5441?s=96&d=mm&r=g","caption":"Angie Lackey"},"url":"https:\/\/admin.acceleratingscience.com\/author\/angie-lackey\/"}]}},"taxonomy_info":{"category":[{"value":71,"label":"Forensics"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM-1024x533.png",760,396,true],"author_info":{"display_name":"Angie Lackey","author_link":"https:\/\/admin.acceleratingscience.com\/author\/angie-lackey\/"},"comment_info":0,"category_info":[{"term_id":71,"name":"Forensics","slug":"forensics","term_group":0,"term_taxonomy_id":71,"taxonomy":"category","description":"","parent":0,"count":94,"filter":"raw","meta":[],"cat_ID":71,"category_count":94,"category_description":"","cat_name":"Forensics","category_nicename":"forensics","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19509,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/cfdna-fragmentomics-analysis-qpcr-cancer-monitoring\/","url_meta":{"origin":13136,"position":0},"title":"qPCR-based fragmentomics for monitoring cancer disease progression","author":"Behind The Bench Staff","date":"March 5, 2026","format":false,"excerpt":"As fragmentomics gains momentum in cancer liquid biopsy research, attention is increasingly turning to how these structural cfDNA signals can be measured in a way that is both sensitive and practical. Established qPCR platforms offer an alternative to sequencing-based approaches for capturing fragment size information with high precision. Using a\u2026","rel":"","context":"In &quot;Bioinformatics&quot;","block_context":{"text":"Bioinformatics","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/bioinformatics\/"},"img":{"alt_text":"Scientist pipetting into a 96 well plate during qPCR workflow for cell free DNA fragmentomics analysis","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/03\/Picture1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19640,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/direct-from-lysate-snp-genotyping-in-research-applications\/","url_meta":{"origin":13136,"position":1},"title":"Direct-from-Lysate SNP Genotyping in Research Applications","author":"Ashleigh Barlow","date":"April 6, 2026","format":false,"excerpt":"Direct-from-lysate workflow enabled by DNA Extract All Reagents compared to traditional DNA purification for SNP genotyping applications. Can You Perform SNP Genotyping Without DNA Purification? The short answer: In many research workflows, direct-from-lysate SNP genotyping can be performed without traditional DNA purification\u2014when appropriate chemistries and verification procedures are used. Direct-from-lysate\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Comparison of traditional DNA purification workflow and direct-from-lysate workflow using DNA Extract All Reagents for SNP genotyping prior to qPCR.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/blog-image-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19805,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/liquid-biopsy-workflow-standardization\/","url_meta":{"origin":13136,"position":2},"title":"Improving the Reliability of Liquid Biopsy in Real-World Settings Through Workflow Standardization: A Discussion with Dr. Matteo Allegretti","author":"Ashleigh Barlow","date":"June 18, 2026","format":false,"excerpt":"Liquid biopsy offers a powerful, noninvasive way to detect and track cancer, but ensuring reliability in real-world settings remains a key hurdle. Variability in workflows and the need for robust verification steps limit widespread adoption. Dr. Matteo Allegretti, Senior Researcher at the Translational Oncology Research Unit at the IRCCS Regina\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Research scientist operating laboratory equipment during liquid biopsy and biomarker research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/Allegretti-Header.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/Allegretti-Header.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/06\/Allegretti-Header.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":19911,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-mirna-profiling-precision-oncology\/","url_meta":{"origin":13136,"position":3},"title":"A scalable multiplex miRNA profiling workflow for precision oncology research","author":"Ashleigh Barlow","date":"August 18, 2026","format":false,"excerpt":"The promise of precision oncology rests on our ability to reliably monitor tumor biology in real time. Circulating microRNAs (miRNAs) offer that opportunity, serving as potentially stable, non-invasive biomarkers linked to disease progression and therapeutic response; however, their adoption in routine practice remains constrained by technical hurdles. (1,2) Because cancer\u2026","rel":"","context":"In &quot;Cancer Research&quot;","block_context":{"text":"Cancer Research","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/cancer-research\/"},"img":{"alt_text":"Scientist pipetting a laboratory sample during molecular biomarker research.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/lisa-blog-picture.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19650,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/history-of-qpcr-30-years\/","url_meta":{"origin":13136,"position":4},"title":"qPCR at 30: Advancing Science Together, from Insight to Impact","author":"Behind The Bench Staff","date":"April 7, 2026","format":false,"excerpt":"Celebrating 30 years of qPCR innovation and the scientific partnerships that continue to drive discovery forward. Thirty years ago, a simple but groundbreaking question changed molecular biology: What if DNA amplification could be measured in real time? The answer became quantitative PCR (qPCR), a technology that allows scientists to monitor\u2026","rel":"","context":"In &quot;Perspectives&quot;","block_context":{"text":"Perspectives","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/perspectives\/"},"img":{"alt_text":"Mosaic image of a scientist composed of smaller images representing qPCR technology, instruments, and scientific research advancements.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/30th-blog-thumbnail_Whitney-Wetzel-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19922,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/qpcr-master-mix-comparison\/","url_meta":{"origin":13136,"position":5},"title":"Think your supermix is good enough? Prove it.","author":"Ashleigh Barlow","date":"August 21, 2026","format":false,"excerpt":"The chemistry of your qPCR supermix can influence analytical sensitivity, specificity, precision, and overall assay performance. Even when you keep the same instrument, assays, and samples, different master mixes can perform differently. That's why we challenge you to put your supermix to the test. Compare it side by side with\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Applied Biosystems probe-based and SYBR Green qPCR master mixes for real-time PCR workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/08\/Untitled-August-18-2026-at-08.39.51-5.jpeg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/01\/Screen-Shot-2020-01-28-at-1.08.26-PM.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/13136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/115"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=13136"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/13136\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/13138"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=13136"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=13136"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=13136"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=13136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}