{"id":14147,"date":"2020-07-09T16:17:06","date_gmt":"2020-07-09T16:17:06","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/?p=14147"},"modified":"2020-07-31T00:52:37","modified_gmt":"2020-07-31T00:52:37","slug":"dynabeads-and-immunoprecipitation-ip-general-advantages","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/","title":{"rendered":"Dynabeads and immunoprecipitation (IP) general advantages"},"content":{"rendered":"<p><em><strong>Dr. Ketil W. Pedersen<\/strong>\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field, in the first of this three-blog series.<\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/hero20image20-20immunoprecipitation20-208a-3.jpg\" width=\"1267\" height=\"713\" \/>Publication trends\u00a0show that immunoprecipitation (IP) using magnetic beads is the fastest growing method for IP. Invitrogen Dynabeads are the most used and cited products in this field. Why? Because Dynabeads offer a balance of capacity\/yield, reproducibility, purity, and cost for capture of specific proteins (immunoprecipitation) and protein complexes (<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-assays-analysis\/protein-interaction-analysis\/co-immunoprecipitation-co-ip-pull-down.html?icid=BID_SPCEP_PG2157_PJT5867_COL33355_20200702_co-immuno\">co-immunoprecipitation<\/a>). Below are general advantages of using Dynabeads magnetic bead technology for immunoprecipitation.<\/p>\n<h2>1) Rapid binding kinetics with magnetic bead technology.<\/h2>\n<p>Due to the fact that number of magnetic beads per given volume is approximately 1000x higher than for the same volume of Sepharose slurry, the chance for Dynabeads to \u201chit\u201d the target is far greater than with Sepharose. Learn more about the History of Dynabeads and see how they compare to Sepharose and other magnetic beads technologies.<\/p>\n<p><strong>Uniformity:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong><\/p>\n<p>Optimal reaction kinetics between the Dynabeads\u2122 and the desired target. This allows for binding of the target and the bead to occur rapidly and efficiently. In many cases, binding is completed in less than 10 min.<\/p>\n<p><strong>Spherical: \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong><\/p>\n<p>The true spherical shape eliminates clumping and non-specific binding associated with irregularly shaped particles.<\/p>\n<p><strong>High Surface Area: \u00a0 <\/strong><\/p>\n<p>The uniform nonporous surface area provides efficient binding and optimal accessibility of your target probe (e.g., primary antibody, protein).<\/p>\n<h3>\u00a0Dynabeads magnetic beads vs. other magnetic bead-based solutions<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"Dynabeads compared to other magnetic beads\" src=\"http:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/dynabeads20magnetic20beads20vs.20other20magnetic-based20solutions-20em5053586-compare-03-3.jpg\" alt=\"Dynabeads compared to other magnetic beads\" width=\"1000\" height=\"180\" \/><span style=\"font-size: 8pt\"><strong>Figure 1.<\/strong> The magnetic bead you choose will affect your results. Dynabeads magnetic beads have a defined surface to carry out the necessary binding, with no inner surface to trap unwanted proteins. (A) Dynabeads products are the most uniform, monodispersed superparamagnetic beads, manufactured with highly controlled product quality to help ensure the highest degree of reproducibility. (B\u2013D) Magnetic particles from alternative suppliers have variable shapes and sizes that trap impurities, resulting in lower reproducibility and increased nonspecific binding.<\/span><\/p>\n<h2>2) Incubation time<\/h2>\n<p>Due to the rapid binding kinetics the protocol is usually very short.<\/p>\n<h2>3) Background<\/h2>\n<p>Due to the rapid binding kinetics and the short incubation time, the background will also be very low.<\/p>\n<h2>4) Trapping of impurities<\/h2>\n<p>No internal volume for binding and\/or trapping of impurities.<\/p>\n<h2>5) Dynabeads uniform physical characteristics produce repeatable results<\/h2>\n<p>Dynabeads are non-porous uniform, superparamagnetic, monodispersed highly cross-linked polystyrene microspheres consisting of an even dispersion of magnetic material throughout the bead. The magnetic beads are coated with a thin layer of highly cross-linked polystyrene shell which encases the magnetic material and prevents any leakage from the beads or trapping of ligands in the bead interior. This provides a defined surface area for the adsorption or coupling of various molecules. Uniformity of bead size and shape provides consistent physical and chemical properties. These uniform physical characteristics lead to high quality reproducible results. Find the right bead by application type using the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/brands\/product-brand\/dynal\/dynabeads-magnetic-separation-products-selection-guide.html?cid=bid_sap_cep_r01_co_cp1362_pjt5867_bid99999_0so_blg_op_awa_an_s00_CEP_Blog\">Dynabeads Selection Guide<\/a>.<\/p>\n<h3>Amount of Antibody (Ab) used: Dynabeads Protein G<\/h3>\n<ul>\n<li>Ab binding to the Dynabeads is usually very fast due to rapid binding kinetics. We have performed several experiments demonstrating that increasing the time for incubation of magnetic beads with Ab is not required. Extending the incubation time to 1h or even overnight will not result in much more Ab binding to the beads. Keep in mind that binding efficiency will be dependent on which bead you have and the Ab subclass, e.g. IgG1 will bind efficiently to <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-assays-analysis\/immunoprecipitation\/automated-immunoprecipitation-protocols.html?icid=BID_SPCEP_PG2157_PJT5867_COL33355_20200702_protein-g\">Protein G<\/a> but to less extent to <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/protein-biology\/protein-assays-analysis\/immunoprecipitation\/automated-immunoprecipitation-protocols.html?icid=BID_SPCEP_PG2157_PJT5867_COL33355_20200702_protein-a\">Protein A<\/a> beads. When incubating your Dynabeads coated with Ab with the lysate containing target of interest, you have to optimize that as this will depend on your primary Abs affinity for the Ag. In an experiment targeting CD9 we are getting strong signal on western blot after only 10 min incubation with target (both for manual &amp; automated workflows). See more on <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/life-science\/dna-rna-purification-analysis\/automated-nucleic-acid-purification\/bead-based-separation-automation.html?icid=BID_SPCEP_PG2157_PJT5867_COL33355_20200702_immuno-protocols\">Immunoprecipitation protocols<\/a> using Dynabeads and KingFisher instruments.<\/li>\n<li>The elution efficiency will depend on the volume. Increased volume will result in higher elution efficiency. Our inhouse experiment shows that increasing the elution volume from 20 \u00b5L to 100 \u00b5L will increase elution efficiency by 20 %. However, our choice of using 20 \u00b5L is related to the fact that we would like to add all sample on the gel and the well capacity (BOLT\u2122 gels) is 40 \u00b5L\/well. In addition, we do get very strong signal after 20 \u00b5L elution in our internal system. This needs to be optimized for each immunoprecipitation.<\/li>\n<li>Amount of Primary Ab: We recommend titrating this. In general we recommend between 1-10 \u00b5g Ab per 50 \u00b5L Dynabeads (per IP). The yield of target will depend on how good your primary Ab is.<\/li>\n<\/ul>\n<h2>6) Reproducible Results using Dynabeads<\/h2>\n<p>Reproducibility is due to easier practical handling of magnetic beads, for instance pipetting. No centrifugation steps are required, or pre-clearing.<\/p>\n<h4>Read more about Invitrogen Dynabeads in the rest of our three-blog series:<\/h4>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/the-human-microbiome-new-frontiers-in-medical-research\/\">The Human Microbiome: New Frontiers in Medical Research<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-magnetic-beads-tips-and-tricks\/\">Dynabeads Magnetic Beads: Tips and Tricks<\/a><\/li>\n<\/ul>\n<p><em><strong>For Research Use Only. Not for use in diagnostic procedures.<\/strong><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field, in the first of this three-blog series. Publication trends\u00a0show that immunoprecipitation (IP) using magnetic beads is the fastest growing method for IP. Invitrogen Dynabeads are the most used and cited products<\/p>\n","protected":false},"author":120,"featured_media":14171,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[172],"tags":[],"division":[],"class_list":{"0":"post-14147","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Dynabeads and immunoprecipitation (IP) general advantages - Behind the Bench<\/title>\n<meta name=\"description\" content=\"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dynabeads and immunoprecipitation (IP) general advantages\" \/>\n<meta property=\"og:description\" content=\"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/\" \/>\n<meta property=\"og:site_name\" content=\"Behind the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-09T16:17:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-31T00:52:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Behind The Bench Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Behind The Bench Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/\"},\"author\":{\"name\":\"Behind The Bench Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"headline\":\"Dynabeads and immunoprecipitation (IP) general advantages\",\"datePublished\":\"2020-07-09T16:17:06+00:00\",\"dateModified\":\"2020-07-31T00:52:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/\"},\"wordCount\":826,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/Hero-Image-Immunoprecipitation-8A.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/\",\"name\":\"Dynabeads and immunoprecipitation (IP) general advantages - Behind the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/Hero-Image-Immunoprecipitation-8A.jpg\",\"datePublished\":\"2020-07-09T16:17:06+00:00\",\"dateModified\":\"2020-07-31T00:52:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\"},\"description\":\"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/Hero-Image-Immunoprecipitation-8A.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/wp-content\\\/uploads\\\/sites\\\/9\\\/2020\\\/07\\\/Hero-Image-Immunoprecipitation-8A.jpg\",\"width\":1920,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/behindthebench\\\/dynabeads-and-immunoprecipitation-ip-general-advantages\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Dynabeads and immunoprecipitation (IP) general advantages\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/\",\"name\":\"Behind the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/behindthebench\\\/#\\\/schema\\\/person\\\/9bbb2d67616274d3d4a21a584f7f4a0c\",\"name\":\"Behind The Bench Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g\",\"caption\":\"Behind The Bench Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/behind-the-bench-staff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Dynabeads and immunoprecipitation (IP) general advantages - Behind the Bench","description":"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/","og_locale":"en_US","og_type":"article","og_title":"Dynabeads and immunoprecipitation (IP) general advantages","og_description":"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field","og_url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/","og_site_name":"Behind the Bench","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-07-09T16:17:06+00:00","article_modified_time":"2020-07-31T00:52:37+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","type":"image\/jpeg"}],"author":"Behind The Bench Staff","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Behind The Bench Staff","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/"},"author":{"name":"Behind The Bench Staff","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"headline":"Dynabeads and immunoprecipitation (IP) general advantages","datePublished":"2020-07-09T16:17:06+00:00","dateModified":"2020-07-31T00:52:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/"},"wordCount":826,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/","url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/","name":"Dynabeads and immunoprecipitation (IP) general advantages - Behind the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","datePublished":"2020-07-09T16:17:06+00:00","dateModified":"2020-07-31T00:52:37+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c"},"description":"Dr. Ketil W. Pedersen\u00a0explains the advantages of Invitrogen Dynabeads, and why they are the most used and cited products in the immunoprecipitation (IP) field","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","width":1920,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/dynabeads-and-immunoprecipitation-ip-general-advantages\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/behindthebench\/"},{"@type":"ListItem","position":2,"name":"Dynabeads and immunoprecipitation (IP) general advantages"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#website","url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/","name":"Behind the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/behindthebench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/behindthebench\/#\/schema\/person\/9bbb2d67616274d3d4a21a584f7f4a0c","name":"Behind The Bench Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/52d5c16ece4bd1c0a49a63521c2b6a25c54a3f0c33f7afed215ba7e0cdff69e3?s=96&d=mm&r=g","caption":"Behind The Bench Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"}]}},"taxonomy_info":{"category":[{"value":172,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A-1024x576.jpg",760,428,true],"author_info":{"display_name":"Behind The Bench Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/behind-the-bench-staff\/"},"comment_info":2,"category_info":[{"term_id":172,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":172,"taxonomy":"category","description":"","parent":0,"count":158,"filter":"raw","meta":[],"cat_ID":172,"category_count":158,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":19184,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/magnetic-cell-separation-how-to-automate-cell-isolation\/","url_meta":{"origin":14147,"position":0},"title":"Magnetic Cell Separation: How to Automate Cell Isolation","author":"Behind The Bench Staff","date":"October 29, 2025","format":false,"excerpt":"In the rapidly advancing field of medical diagnostics, liquid biopsy stands out as an innovative technique that is advancing the way we detect and monitor diseases. Unlike traditional biopsies, which require invasive procedures to extract tissue samples, liquid biopsy offers a minimally invasive alternative by isolating cells from complex samples\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Automated cell isolation","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/10\/Blog-32-Automated-Cell-Isolation_1600x350px.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19697,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/allogeneic-cell-therapies-enhancing-patient-access-via-off-the-shelf-options\/","url_meta":{"origin":14147,"position":1},"title":"Allogeneic cell therapies: Enhancing patient access via off-the-shelf options","author":"Behind The Bench Staff","date":"May 16, 2026","format":false,"excerpt":"Chimeric Antigen Receptor (CAR) T cell therapy has transformed treatment paradigms for hematologic malignancies. However, most FDA-approved CAR-T cell therapies today are autologous, meaning they are manufactured individually from each patient\u2019s own T cells. While effective, this approach presents significant manufacturing constraints, including long timelines, dependence on patient health for\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"CTx Feature Image","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/05\/Chapter-6-CTx-HB-BKG-4-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19271,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/multiplex-qpcr-basics-guide\/","url_meta":{"origin":14147,"position":2},"title":"Multiplex vs. Singleplex qPCR: What do I need to know?","author":"Ashleigh Barlow","date":"December 3, 2025","format":false,"excerpt":"Real-time PCR (qPCR) has transformed how scientists detect and quantify nucleic acid targets, offering analytical sensitivity, speed, and scalability. Many real-time PCR reactions measure a single target per well \u2014 a setup called singleplex qPCR. However, the effectiveness of real-time PCR can be increased by an approach called multiplex qPCR.\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/12\/Web-header-900-x-600-custom-web-page-size-feature-pods.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":19658,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/is-raman-spectroscopy-a-better-verification-method-in-pharmaceutical-manufacturing\/","url_meta":{"origin":14147,"position":3},"title":"Is Raman Spectroscopy a Better Verification Method in Pharmaceutical Manufacturing?","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Article Summary Verification testing is a critical step in pharmaceutical manufacturing, helping to ensure that every product released meets strict safety, quality, and regulatory standards. Verification helps ensure that products contain the correct active ingredients, meet concentration specifications, are free from contamination, and maintain structural and chemical integrity. This process\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"Yellow pill and red check mark sitting on brown wood surface in front of abstract defocused background. Horizontal composition with selective focus and copy space. Front view. Drug approval concept.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/04\/iStock-1223991858.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19837,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/managing-formulation-fill-finish-in-the-car-t-cell-manufacturing-process\/","url_meta":{"origin":14147,"position":4},"title":"Managing Formulation, Fill &amp; Finish in the CAR T-Cell Manufacturing Process","author":"Behind The Bench Staff","date":"July 28, 2026","format":false,"excerpt":"Chimeric antigen receptor (CAR)-T cell therapies represent a paradigm shift in medicine, offering personalized, potentially curative treatments for cancer and other serious diseases. Unlike traditional biologics, CAR T-cell products are living therapeutics. Highly sensitive cells whose quality, safety, and efficacy depend on careful handling at every step of the manufacturing\u2026","rel":"","context":"In &quot;General&quot;","block_context":{"text":"General","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/general\/"},"img":{"alt_text":"Scientist working in a lab","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2026\/07\/Hero_image_1920x1080.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":19150,"url":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/scanning-electron-microscopy-for-microneedle-patch-testing\/","url_meta":{"origin":14147,"position":5},"title":"Scanning Electron Microscopy for Microneedle Patch Testing","author":"Marlene Gasdia-Cochrane","date":"September 30, 2025","format":false,"excerpt":"Microneedle patches represent a significant advancement in drug delivery systems. These patches offer a painless and efficient method for administering medications through the skin. The application of Scanning Electron Microscopy (SEM) in testing microneedle patches has provided valuable insights into their structural integrity and performance. What are Microneedle Patches Microneedle\u2026","rel":"","context":"In &quot;Pharma &amp; Biotech Manufacturing&quot;","block_context":{"text":"Pharma &amp; Biotech Manufacturing","link":"https:\/\/admin.acceleratingscience.com\/behindthebench\/pharmamfg\/"},"img":{"alt_text":"MicroNeedle","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2025\/09\/MicroNeedle_4_7-002.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/behindthebench\/wp-content\/uploads\/sites\/9\/2020\/07\/Hero-Image-Immunoprecipitation-8A.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/users\/120"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/comments?post=14147"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/posts\/14147\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media\/14171"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/media?parent=14147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/categories?post=14147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/tags?post=14147"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/behindthebench\/wp-json\/wp\/v2\/division?post=14147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}